Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-0659 (SFD)
li - P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: CaNZPAgi oP 13-00000659 80221 VIA PESSARO 777-210-032-242 -29894 - DWELLING - SINGLE FAMILY LOW DENSITY RESIDENTIAL 623345 4 VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT -` INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 9/10/13 Owner: HALCOVICH/HERTZ-POLAKOV & NEIL P.O.. BOX 356 DETACHED LA QUINTA, CA 92247 ( Architect or Engineer: NIS ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury th t I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busin d Prof sionals Code, and my License is in full force and effect. License Class: B License No.: 799449 Date: 1,1741 Contractor: NIR -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Contractor: D JACOBS HOMES INC, PETER P.O. BOX 356�� 1 V 2033 LA QUINTA, CA 92247 (760) 777-9921 CITY QP�p Lic. No.: 799449 FIIUAIUr - QUINTA ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 901363313 1 certify that, in the performance f the work for which this permit is issued, I shall not employ any person in any manner so as ecome s bject to the workers'compensation laws of California, and agree that, if I should o e su ' t to the workers' compensation provisions of Section ,f 3700 of the Labor Code, o h comply with those provisions. '/ Date: y? Applicant: WARNING: FAILURE TO SECURE WORKERS' C PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDREDTH OUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS -PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above to ation ' correct. I agree to comply with all city and county ordinances and state laws relating to building c tr io d hereby authorize representatives of this county. to enter upon the above-mentioned property for ti p poses. Date:i_zP_/ /Signature (Applicant or Agent): ,p 0 Application Number . . . . . 13-00000659 ------ Structure Information 7130 SQ. FT. SFD ----- Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 5.00 FIRE SPRINKLERS 13d GARAGE SQ FTG 1015.00 PATIO SQ FTG 900.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 5660.00 ---------------------- ----------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 485.00 Permit . . . BUILDING 2013 Additional desc . . Permit Fee . . . . 810.87 Plan Check Fee 00 Issue Date . . . . Valuation . . . . 623345 Expiration Date . . 3/09/14 Qty Unit Charge Per Extension BASE FEE 573.43 424.00 .5600 ---------------------------------------------------------------------------- THOU BLDG $200,001-$1M 237.44 Permit . . . ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 214.49 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/09/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20. 23.83 1.00 23.8300 EA ELEC SERVICES 23.83 1.00 23.8300 EA ELEC TEMP POWER POLES 23.83 1.00 143.0000 ---------------------------------------------------------------------------- LS ELEC NEW RES, FIRST 1 KSF 143.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 180.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date . . 3/09/14 Qty Unit Charge Per Extension BASE FEE 117.00 7.00 9.0000 ---------------------------------------------------------------------------- THOU GRADING 1001-10,000 63.00 Permit . . . . . . MECHANICAL 2013 LQPERMIT C.- Application Number . . . . . 13-00000659 Permit . . . MECHANICAL 2013 Additional desc . . Permit Fee. 726.96 Plan Check Fee . Issue Date . . . . Valuation . . . . Expiration Date . . 3/09/14 Qty Unit Charge Per Extension 28.00 11.,9200 Extension 7.00 35.7500 EA MECH FURNACE 250.25 2.00 23.8300 EA MECH WALL HEATER 47.66 7.00 35.7500 EA MECH CONDENSER/COMP 250.25 12.00 11.9200 EA MECH VENT FAN 143.04 3.00 ---------------------------------------------------------------------------- 11.9200 EA MECH EXHAUST HOOD 35.76 Permit . . . PLUMBING 2013 Additional desc . . Permit Fee . . . . 417.19 Issue Date . . . . Expiration Date . . 3/09/14 Plan Check Fee . . .00 Valuation . . . . 0 Qty Unit Charge Per Extension 28.00 11.,9200 EA PLBG FIXTURE/TRAP 333.76 1.00 11.9200 EA PLBG BUILDING SEWER 11.92 2.00 11.9200 EA PLBG WATER HEATER/VENT 23.84 1.00 11.9200 EA - PLBG WATER INST/ALT/REP 11.92 1.00 35.7500 LS PLBG GAS SYS, 5+ OUTLETS 35.75 ---------------------------------------------------------------------------- Special Notes and Comments 7130 sq.ft.SFD, 1015 sq.ft. garage & 900 sq. ft. covered patio. THIS PERMIT DOES NOT INCLUDE POOL, SPA AND BLOCK WALLS BBQ, FIRE PIT. 2010 CALIFORNIA CODES June 24, 2013 8:13:35 AM jjohnson. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 940.26 BLDG STDS ADMIN (SB1473) 25.00 DIF COMMUNITY CENTERS -RES 129.00 DIF CIVIC CENTER - RES 942.00 DIF FIRE PROTECTION -RES 433.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 344.00 FLAN CHECK, ELECTRICAL 99.62 DIF PARK MAINT FAC - RES 40.00 PLAN CHECK, MECHANICAL 405.17 PLAN CHECK, SFD GRADING 143.00 PLAN CHECK, PLUMBING 359.96 DIF PARKS/REC - RES 2048.00 BLDG PC 200K -1M 1753.15 LQPERMIT .1) Application Number . . . . . 13-00000659 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STRONG MOTION (SMI) - RES 57.61 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC -RES 116.00 DIF TRANSPORTATION - RES 2842.00 Fee summary Charged Permit Fee Total 2349.51 Plan Check Total .00 Other Fee Total 12530.21 Grand Total 14879.72 LQPERMIT Paid Credited Due .00 .00 2349.51 .00 .00 .00 1000.00 .00 11530.21 1000.00 .00 13879.72 Building r ) Address Mailing Address • • ��J 13.OWA P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO SSG i'I[3 LA QUINTA, CALIFORNIA 92253 Vlly LIIJ I t,IezA fir /Z 47,./ , -zl7z, Address & Classif. I Lic. # Designer Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the Provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to'the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. OCC. GRP. A.P. Number_ 7 72 - 2—1,6 - 0 -3 2 Legal Description r/Q � 2 Z 5�y Project Description Sq. Ft.No. Size % D No. Dw. Stories 47, Units New fX Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setba.:k from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Cate Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOIR-r: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: !Frank & Wendy Halcovich Date: September 11, 2013 Owner's Name: Phone No. Project Address: 80-221 Via Passaro, La Quinta, CA 92253 Project Description: New Single Family Dwelling Unit APN: 777-210-032-5 Tract #: Lot #'s Type of Development: Residential XX Commercial Total Square Feet of Building Area: 7,130 SQ FT Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authord sign behalf of the owner/developer. Dated: Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existir._g Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 7,130 Amount per Sq.Ft. $3.20 Amount Collected $22,816.00 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst NOTICE OF 90 DAY PERIOD FOR PROTEST OF FF.>!' AND STATtMENVOF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that tl is.Digirict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the paynent of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed s as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/myclocs'devfees/ceilificatcol'compliance form updated 3-2007 112010 RECORDING REQUESTED BY: Equity Title AND WHEN RECORDED MAIL TO: Mr. Frank Halcovich and Mrs. Wendy Hertz-Polakov c/o 81161 Indio Blvd. Indio, CA 92201 ozo -�/ o THIS GRANT DEED DOC # 2012-0522334 10/31/2012 02:57 PM Fees: $18.00 Page 1 of 2 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W.. Ward Assessor, County Clerk & Recorder "This document was electronically submitted to the County of Riverside for recording,'* Recelpted by; MRUIZ RECORDER'S USE ONLY: Ce........ N... n•Uene THE UNDERSIGNED GRANTOR(S) DECLARES) DOCUMENTARY TRANSFER TAX is $660.00 [Xj computed on full value of property conveyed, or { j computed on full value less value of liens or encumbrances remaining at time of sale. [ ] Unincorporated area . [X] City of La Quinta AND FOR A VALUABLE 'CONSIDERATION, receipt of which is hereby acknowledged, K. RANDALL•BURT,TRUSTEE AND JULIA E.BURT, TRUSTEE OF THE BURT FAMIL"Y:TRUIST, U.D.T. DATED MARCH 2S; 2003.'" , ...... . hereby GRANT(s) to:,. Frank Halcovich and Wendy Hertz-Polakov, Husband and Wife as Joint Tenants, as to an undivided 60.0000% Interest and Walter K. Nell and Laura E. Neil, Husband and Wife as Joint Tenants, as to an undivided 60.0000% Interest, all as Tenants in Common the real property In the City of La Quints, County of Riverside, State of California, described as: Parcel 1: Lot 242 of Amended No. 2 Tract No. 29894-2 as shown by map on file in Book, Page of Maps, in the Office of the County Recorder of said County ... See Exhibit "A" for complete legal description Also Known as: unimproved land with address of: 80221 Via Pessaro, La Quinta, CA 92253 AP* 777-210-032-5 DATED October 26; 2012 STATE OF CALIFQRNIA , COUNTY OF t On f6 6m -Lck before me, A Notary Public in aaU for sF who proved to me on the basis' �of satisfactory evidence to be the person(s) whose nameoe s) subscribed to the y✓lthlp Instrument and acknowledg me that ilaf9h ft") executed the same' 01.1 ff el authorized capacity(les), and that by f)Islber e' sjj""gna e(s) on the Instrument the person(s), or the. en upon behalf of which the person(s) acted, executed the Instrument j certify under PENALTY OF PERJURY under the laws of the State !Of cauforitia that the`foragoing paragraph Is true and correct.. WITNESS my h4Kdand bMelal seal.:.':', BURT FAMILY TRUST, U.D.T. DATED MARCH 25, 2003 BY: *.-Randall Burt, Trustee .r Jida E. Burt, Trustee tl10LLY H1:U91NKVELD COMMS 1978133 Signature (Seal) MAIL TAX STATE TO PARTY SHOWN BELOW, IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE: -: Recording Requested By and When Recorded Return to: JULIA BURT LAW and El Paseo Law Group 73-700 El Paseo Patin Desert, CA 92260 10 DOC # 2013-0052927 01/31/2013 08:57A Fee:18.00 Page i of 2 Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk $ Recorder 11111111111111111111111111111111111111 III 1111111111111 S R I U PAGE SIZE DA MISC I LONG RFD I COPY 2 M A L 465 1 426 CPC93 NCOR SMF NCHG CTY UNI �-©— -b7gob T: GRANT DEED THE UNDERST CiRAN'1'O.R I fERBBY DECLARES THAT THE DO U N I ARY TRANSFER TAX IS 9:0.00 (3) Is eXer}hr j-9 "Ill is it tlonallde blit and the brantur mccived authins In return, R & T Coda §11911. FOR V, , receipt of which is hereby acknowledged, L�o WALTER K. NEIL, and LAURA E. NEIL, husband and wife as Joint Tenants, as to their undivided 50% interest as Tenants in Common, hereby grants their 50% interest to FRANK HALCOVICH and WENDY HERTZ- 00LAKOV, Husband and Wife as Joint Tenants, the real property in the City of La Quinta, Codrity of Riverside, State of California, more particularly described as follows: See Exhibit "A" for Legal Description. A.P.N.: 777-210-032-5 Commonly known as: 80221 Via Pessaro, La Quinta, California 92253 Dated: \ l y t 13- W ER K. NEIL Dated: % I N j t3 �'- W - LAURA E. NEIL State of California ) County of Riverside ) On'1taw„M%M H , — 2013, before me, M `Zwe(\watw5 , Notary Public, personally appeared WALTER K. NEIL and LAURA E. NEIL, who proved to me on the basis of satisfactory evidence to be the persons whose names are subscribed to the within Instrument and acknowledged to me that they executed the same In their authorized capacities, and that by their signatures on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. Wil ESS my hnnd and official seal. WNj N M. ZACHARIAS . #1856995 [t1 i w uelfom MX COUNTYotary Public Ex JUNE 29, 2013 Commission Explres: S'uNe, V% , 2013 Commission No.: ) 46 S Lo 14 5 P BUILDING ENERGY ANALYSIS REPORT PROJECT: Lot 242 - The Hideaway The Hideaway La Quinta, ca 92253 Project Designer: Brock J Payton Inc 8391 Beverly Blvd. #482 Los Angeles, ca 90048 310-720-6589 Report Prepared by: Maria Jeccett Chasco BREEZE AIR CONDITIONING 75-145 St. Charles Place Palm Desert, CA 92211 (760) 346-0855 Job Number: RECEIVED 1�Y Or;:1-� C I�M�ji 2 013 BUILDING 6, SAFETY DEPT. UINTA Date: APPR - c rr p ELOPMENT 5/15%2013 OR CONS � DATE_4! 4 BY The EnergyPro computer program has been used to perform the calculations,summarized-in=this'd report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidentia 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15T15:01:10 /D: I . TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 14 HVAC System Heating and Cooling Loads Summary 17 Room Load Summary 24 Room Heating Peak Loads 31 Room Cooling Peak Loads 38 PI CITY OF LjrN ()UIN oT RVILDING & SAFETY DEPT. FOi 3 CONSTRUCTION D; T E --- BY EnergyPro 5.1 by EnergySoft Job Number: ID: User Number. 3665 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 Project Address The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,686 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for detais. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 4,965 New Roof Wood Framed Attic R-38 7,686 New Slab Wood Framed w/Crawl Space R-38 6,523 Perim = 822' New Door Opaque Door None 80 New Floor Wood Framed w/Crawl Space R-22 1,163 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (E) 221.5 0.330 0.29 none none Bug Screen New Rear (S) 164.0 0.370 0.26 none none Bug Screen New Right (tM 136.7 0.330 0.29 none none Bug Screen New Rear (S) 95.0 0.370 0.26 none none Bug Screen New Right (W) 89.0 0.370 0.26 none none Bug Screen New Left (E) 304.8 0.370 0.26 none none Bug Screen New Right (tM 120.0 0.370 0.26 none none Bug Screen New Front (N) 120.0 0.370 0.26 none none Bug Screen New Front (N) 183.7 0.330 0.29 none none Bug Screen New Left (E) 488.8 0.370 0.26 none none Bug Screen New Left (E) 24.0 0.330 0.29 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Large Packaged Air Coi 12.5 EER `---.Setba:k New 1 Central Furnace 80% AFUE Large Packaged Air Coj. --15'0 EERY -T �Setb :k New 1 Central Furnace 80% AFUE Large Packaged,AirtCoi, U2:5 EER rte/ PSetb .--k New HVAC DISTRIBUTION� Location Heatin �,4cl & � �'�" ` uct Coolin ) uct�L'ocabbh— , -Value Status Hvac #1 Ducted Ducted, �AtfYc, Ce�nWns, ve t�e`r1' 0 New Hvac #2 Ducted Ducted Attic, Ceiling Ins, vented 0 New Hvac #3 Ducted Ducted I Attic, Ceiling /n$ verite New WATER HEATING j oA Qty. Type Gallons Min–Eff Distribution Status 2 Large Gas 100 0.80 Kitchen Pipe Ins New EnetqyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15T15:01:10 ID: Page 3 of 48 PERFORMANCE CERTIFICATE: Residential Part - of 5 CF-1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Additicn/Alteration Date 5/15/2013 Project Address The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Addition 7,686 n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part.2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (S) 52.3 0.330 0.29 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Large Packaged Air Coi 12.5 EER k New 1 Central Fumace 80% AFUE Large Packaged Airo epa _ k New 1 Central Fumace 80% AFUE Larg Pa ke • r Q 12c5 E R tba New HVAC DISTRIBUTION ILOING & o, ,D uct Location HeatingCoo rn U uetl2 . _a04 � -Value Status Hvac #4 Ducted Ducted'QTe' 8 New Hvac #5 Ducted Ducted Attic, Ceiling Ins, vented 8. New Hvac #6 Ducted Ducted Attic, Ceiling Ins AY New WATER HEATING Qty. Type Gallons Mih—Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15715:01:10 ID: Page 4 of 48 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 Project Address The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,686 Addition n/a It of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for detai s. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5) Status FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Large Packaged Air Cog 12,5=EER , * , , t Setback New irTy Ov- LJ -1' I c1 !tl fllNC, & S;�t t;�� HVAC DISTRIBUTIONPRk,_,)V Location HeatingCoolin t: Du Ductt� cationRUCTION R -Value Status Hvac #7 Ducted Ducted # Attic, Ceiling Ins, vented 8.0 New V WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15T15:01:10 ID: Page 5 of 48 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford-White Corp. D-100S250"""' is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System Hvac #1 must serve only Sleeping Areas. The non-closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. � IINTA C11 r .. , ,e tntr SAFETY DEPT PPRO` I�_—t N Fail CoNb I tl BY TG EnergyPro 5.1 by EnerqySoft User Number., 3665 RunCode: 2013-05-15715:01:10 ID: Page 6 of 48 PERFORMANCE CERTIFICATE: Residential (Part :3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lot 242 - The Hideaway ❑ Multi Family ❑ Existing+ Adcbition/Alteration 1511512013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 0.00 0.00 0.00 Space Cooling 0.00 0.00 0.00 Fans 0.00 0.00 0.00 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 0.00 0.00 0.00 Percent Better Than Standard: 0.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 1,565 304 Fuel Available at Site: Natural Gas (E) 2,848 1,039 Raised Floor Area: 1,163 (S) 795 311 Slab on Grade Area: 6,523 (tM 1,837 346 Average Ceiling Height: 11.3 Roof 7,686 0 Fenestration Average U-Factor: 0.36 TOTAL: 2,000 Average SHGC: 0.27 Fenestration/CFS. Ratio: 26.0 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company BREEZE AIR CONDITIONING CITY OF 75-145 St. Charles Place Ma Jeccett Chasco & SAFETY DE. t - 5/15!2013 Address Name �US�►y�e N ,Date City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855, Si P O\JSqnrre M resented in this set The individual with overall design responsibility hereby ce 4 ifies that Aocoposed�bu tding design rtecifications, of construction documents is consistent with the other compliance forms and worksheets, with the and with any other calculations submitted with this permit application, and recognizes pat com l--nce-u ing duct design, duct sealing, verification of refrigerant charge, insulation installatior>_quafity and bui in. aling require installer testing and certification and field verification by an approved=HERS er. Designer or Owner (per Business & Professions Code) Company Brock J Payton Inc Address 8391 Beverly Blvd. #482 Name Brock Payton City/State/Zip Los Angeles, ca 90048 Phone 310-720-6589 Signed License # Date EnemyPro 5.1 by EnemySoft User Number: 3665 RunCode: 2013-05-15715:01:10 /D: Page 7 of 48 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addtion/Alteration Date 5/15/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Apperdix Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Wall 486 0.069 R-21 90 90 New 4.3.1-A6 Zone 1 Wall 103 0.069 R-21 180 90 New 4.3.1-A6 Zone 1 Wall 72 0.069 R-21 270 90 New 4.3.1-A6 Zone 1 Roof 1,377 0.025 R-38 0 0 New 4.2.1-A21 Zone 1 Slab 1,377 0.023 R-38 0 180 New 4.4.1-A 16 Zone 1 Wall 41 0.069 R-21 180 90 New 4.3.1-A6 Zone 2 Wall 153 0.069 R-21 270 90 New 4.3.1-A6 Zone 2 Roof 592 0.025 R-38 0 0 New 4.2.1-A21 Zone 2 Slab 592 0.023 R-38 0 180 New 4.4.1-A 16 Zone 2 Wall 242 0.069 R-21 0 90 New 4.3.1-A6 Zone 3 Door 24 0.500 None 0 90 New 4.5.1-A4 Zone 3 Wall 253 0.069 R-21 90 90 New 4.3.1-A6 Zone 3 Wall 251 0.069 R-21 270 90 New 4.3.1-A6 Zone 3 Roof 1,132 0.025 R-38 0 0 New 4.2.1-A21 Zone 3 Slab 1,132 0.023 R-38 0 180 New 4.4.1-A 16 Zone 3 Wall 269 0.069 R-21 0 90 New 4.3.1-A6 Zone 4 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 9.7 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Dods Zone 1 2 Window 19.3 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 1 3 Window 19.3 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 1 4 Window 19.3 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Dods Zone 1 5 Window 19.3 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Doors Zone 1 6 Window 9.7 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Doors Zone 1 7 Window 9.7 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 1 8 Window 19.5 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 1 9 Window 19.5 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 1 10 Window 116.0 0.370 NFRC 0.26 NFRC 180 New Alumn French Door Zone 1 11 Window 28.6 0.330 NFRC 0.29 NFRC 270 New Sierra Pacific Windows & Docrs Zone 1 12 Window 95.0 0.370 NFRC 0.26 NFRC 180 New Weiland Door Zone 2 13 Window 89.0 0.370 NFRC 0.26 NFRC 270 New Weiland Door Zone 2 14 Window 15.0 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 3 15 Window 96.8 0.370 NFRC 0.26 NFRC 90 New Alumn French Door Zone 3 16 Window 48.0 0.370 NFRC 0.26 NFRC 270 New I Alumn French Door Zone 3 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H tWd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76� , _. �11 i ,� 3 Bug Screen 0.76 r I Y 10 t' r --r 4 Bug Screen 0.76 5 Bug Screen 0.76 011 6 Bug Screen 0.76 4 7 Bug Screen 0.76 nn •^ I\(. 1 iiU t 8 Bug Screen 0.76 9 Bug Screen 0.76 1 10 Bug Screen 0.76 1 _BY - 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15715:01:10 ID: Page 8 of 48 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Adcition/Alteration Date 511512013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Apperdix Factor Cavi!Exterior Frame Interior Frame Azm I Tilt Status 4 Location/Comments Door 32 0.500 None 0 90 New 4.5.1-A4 Zone 4 Wall 130 0.069 R-21 90 90 New 4.3.1-A6 Zone 4 Wall 383 0.069 R-21 90 90 New 4.3.1-A6 Zone 4 Wall 196 0.069 R-21 270 90 New 4.3.1-A6 Zone 4 Roof 1,529 0.025 R-38 0 0 New 4.2.1-A21 Zone 4 Slab 1,529 0.023 R-38 0 180 New 4.4.1-A 16 Zone 4 Wall 153 0.069 R-21 0 90 New 4.3.1-A6 Zone 5 Door 24 0.500 None 0 90 New 4.5.1-A4 Zone 5 Wall 57 0.069 R-21 90 90 New 4.3.1-A6 Zone 5 Wall 446 0.069 R-21 270 90 New 14.3.1-A6 Zone 5 Roof 1,061 0.025 R-38 0 0 New 4.2.1-A21 Zone 5 Slab 1,061 0.023 R-38 0 180 New 4.4.1-A 16 Zone 5 Wall 343 0.069 R-21 0 90 New 4.3.1-A6 Zone 6 Wall 145 0.069,R-21 90 90 New 4.3.1-A6 Zone 6 Wall 1 1761 0.069 R-21 180 90 New 4.3.1-A6 Zone 6 Roof 1 8321 0.0251R-38 1 0 0 New 4.2.1-A21 Zone 6 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 48.0 0.370 NFRC 0.26 NFRC 270 New Alumn French Door Zone 3 18 Window 120.0 0.370 NFRC 0.26 NFRC 0 New Weiland Door Zone 4 19 Window 3.6 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Docrs Zone 4 20 Window 23.5 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows 8 Dons Zone 4 21 Window 3.6 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Dogs Zone 4 22 Window 3.6 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Docrs Zone 4 23 Window 80.0 0.370 NFRC 0.26 NFRC 90 New Weiland Door Zone 4 24 Window 328.8 0.370 NFRC 0.26 NFRC 90 New Weiland Door Zone 4 25 Window 80.0 0.370 NFRC 0.26 NFRC 90 New Weiland Door Zone 4 26 Window 3.6 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 4 27 Window 3.6 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 4 28 Window 3.6 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 4 29 Window 3.6 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs Zone 4 30 Window 12.8 0.330 NFRC 0.29 NFRC 2701 New I Sierra Pacific Windows & Docrs Zone 4 31 Window 12.8 0.330 NFRC 0.29 NFRC 2701 New I Sierra Pacific Windows & Docrs Zone 4 32 Window 12.8 0.330 NFRC 0.29 NFRC 2701 New I Sierra Pacific Windows & Docrs Zone 4 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt REA Dist Len H t Dist Len H t 17 Bug Screen 0.76 Yrk 18 Bug Screen 0.76 A 1 � 1 '-' 19 Bug Screen 0.76 ('.1" Y l C L 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 1 /� - • . 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 IBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15715:01:10 ID: Page 9 of 48 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Add tion/Alteration Date 5/15/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments Slab 832 0.023 R-38 0 180 1 New 4.4.1-A 16 Zone 6 Wall 174 0.069 R-21 0 90 New 4.3.1-A6 Zone 7 Wall 355 0.069 R-21 90 90 New 4.3.1-A6 Zone 7 Wall 164 0.069 R-21 180 90 New 4.3.1-A6 Zone 7 Wall 373 0.069 R-21 270 90 New 4.3.1-A6 Zone 7 Roof 1,163 0.025 R-38 0 0 New 4.2.1-A21 Zone 7 Floor 1,163 0.034 R-22 0 180 New 4.4.1-A5 Zone 7 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 160.0 0.370 NFRC 0.26 1 NFRC 90 New Alumn French Door Zone 5 34 Window 24.0 0.370 NFRC 0.26 NFRC 270 New Alumn French Door Zone 5 35 Window 7.0 0.330 NFRC 0.29 NFRC 270 New Sierra Pacific Windows & Doors Zone 5 36 Window 14.3 0.330 NFRC 0.29 NFRC 270 New Sierra Pacific Windows & Doors Zone 5 37 Window 9.7 0.330 NFRC 0.29 NFRC 270 New Sierra Pacific Windows & Doors Zone 5 38 Window 9.7 0.330 NFRC 0.29 NFRC 270 New Sierra Pacific Windows & Doors Zone 5 39 Window 29.0 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 6 40 Window 7.0 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 6 41 Window 29.0 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 6 42 Window 7.0 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 6 43 Window 29.0 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doers Zone 6 44 Window 8.2 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 6 45 Window 8.2 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Dods Zone 6 46 Window 8.2 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 6 47 Window 8.2 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Dods Zone 6 48 Window 24.0 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Docrs I Zone 6 (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len I G I t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 _ 36 Bug Screen 0.76 37 Bug Screen 0.76 P.1 tll_.L�1 IN 1 38 Bug Screen 0.76 1 r;"' _? J v C 39 Bug Screen 0.76 r+- - iib rPLC 40 Bug Screen 0.76 V 41 Bug Screen 0.76 42 Bua Screen 0.76 43 Bug Screen 0.76 n rLT 44 Bug Screen 0.76 t _ 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 1 0.76 EnergyPro, 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15715:01:10 ID: Pae 10 of 48 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Lot 242 - The Hideaway Building Type m Single Family ❑ Addition AlonE ❑ Multi Family ❑ Existing+ Add tion/Alteration Date 5/15/2013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGCz Azm Status Glazing Type Location/Comments 49 Window 48.0 0.370 NFRC 0.26 NFRC 90 New Aiumn French Door Zone 6 50 Window 48.0 0.370 NFRC 0.26 NFRC 180 New A/umn French Door Zone 6 51 Window 8.2 0.330 NFRC 0.29 NFRC 180 New Sierra Pacific Windows & Dods Zone 6 52 Window 8.2 0.330 NFRC 0.29 NFRC 180 New Sierra Pacific Windows & Doors Zone 6 53 Window 5.2 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 7 54 Window 5.2 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Doors Zone 7 55 Window 5.2 0.330 NFRC 0.29 NFRC 0 New Sierra Pacific Windows & Docs Zone 7 56 Window 6.9 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Doors Zone 7 57 Window 6.9 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Doors Zone 7 58 Window 19.2 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Doors Zone 7 59 Window 6.9 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Doors Zone 7 60 Window 6.9 0.330 NFRC 0.29 NFRC 90 New Sierra Pacific Windows & Doors Zone 7 61 Window 6.9 0.330 NFRC 0.29 NFRC 180 New Sierra Pacific Windows & Doors Zone 7 62 Window 29.0 0.330 NFRC 0.29 NFRC 180 New Sierra Pacific Windows & Dom Zone 7 63 Window 29.0 0.330 NFRC 0.29 NFRC 270 New Sierra Pacific Windows & Docrs Zone 7 (1) LI-Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len I H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 lBug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 UIL t "' ' ,R-- 62 Bug Screen 0.76 63 Bug Screen 0.76 t� s _ BY EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-0$ F:01:10 Pae 11 of 48 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Lot 242 - The Hideaway Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Adcjtion/Alteration Date 5/15/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Hvac #1 Master Suite & Bath 1,377 13,770 Hvac #2 Sitting Room 592 5,920 Hvac #3 Game Room & Bedroom 1 1,132 11,320 Hvac #4 Great Room & Kitchen, Breakfast 1,529 27,522 Hvac #5 Dining, Laundry & Pantry 1,061 10,610 Hvac #6 Home Gym, Entry, Guest Room 832 8,320 Hvac #7 Bedroom 1 & 3 1,163 9,304 Totals 1 7,686 01 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. 'Ehermostat Type Status Hvac #1 1 Central Furnace 80% AFUE Large Packaged Air Con 12.5 EER Setback New Hvac #2 1 Central Furnace 80% AFUE Large Packaged Air Con 15.0 EER Setback New Hvac #3 1 Central Fumace 80% AFUE Large Packaged Air Con 12.5 EER Setback New Hvac #4 1 Central Furnace 80% AFUE Large Packaged Air Con 12.5 EER I Setback New Hvac #5 1 Central Furnace 80% AFUE I Large Packaged Air Con 12.5 EER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R-VEIue Ducts Tested? Status Hvac #1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New Hvac #2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New Hvac #3 Ducted Ducted Attic, Ceiling Ins, vented 8.01 ❑ New Hvac #4 Ducted Ducted JAttic, Ceiling Ins, vented 8.01 ❑ New Hvac #5 Ducted Ducted Attic, Ceiling Ins, vented 8.01 ❑ New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White Corp. D -1C 2 Large Gas Kitchen Pipe Ins 250,000 100 0.80 2.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length QUIN S FEV E Pip ;I►yG stena,Nam(r— Len q Pipe Diameter Insul. Thick. Qt . HP Plenum Outside B FdE v; QLD M EnergyPro, 5.1 by EnergySoft User Number: 3665 RunCode: 20f3 -05-15T15:01:10 ID: Pae 12 of 48 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Lot 242 - The Hideaway Building Type 121 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/15/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Totals 7,686 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Hvac #6 1 Central Furnace 80% AFUE Large Packaged Air Con 12.5 EER Setback New Hvac #7 1 Central Furnace 80% AFUE Large Packaged Air Con 12.5 EER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R-Value Ducts Tested? Status Hvac #6 Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New Hvac #7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New 13 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � ^Ns� �yc Plenum Outside Bu ,leg-s.111 i� , „w A � /y / - OF L� D Pipe tKI(S sterni a , e Lent Pipe Diameter Insul. Thick. Qty. HP r1f"NN,i ❑ R UIN101 UIW— Ry DAT_ ------- EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 201:3-0545M: :1 b ID: Pae 13 of 48 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Lot 242 - The Hideaway 5/15/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum comaonent performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit sir leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -611 Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Va or barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no qreater than 2.0perm/inch and shall be protected from physical damage and UV light deteriorat£on. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opEning of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 1 12(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal stendard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated betwee : eating -source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water sys e(Es -15;•p�rne Wthe re a ents of Standards Table 123-A. ..., 0 ACDE• �r 150(j)3A: Insulation is protected from damage, includingthat du toast li fitflmo stuGe a wi meat m intanan a and wind. §1500)3A: Insulation for chilled water piping and refrigerant suctio lines inru84's1La-g6por !6tardaq��� anclo d entirely in conditioned space. 1 RISCjV 150(j)4: Solar water -heating systems and/or collectors are certifie�tl by the Solar Rating and Certification Corpo ation. B_ DATE —�� EnergyPro 5.1 by EnergySoR User Number: 3665 Run Code: 2013=0 -15T15:01:10 ID: Page 14 of 48 MANDATORY MEASURES SUMMARY: Residential Pae 2 of 3 MF-1 R Project Name Date Lot 242 - The Hideaway 5/15/2013 §150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities a!id support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductio is in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Mole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and (heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that wil. allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no bower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain E line-voltage socket or line- voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw-base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling uni-,s larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are-contro l5`dby a manual on occupant sensor, dimmer, energy management system (FMCS), or a multi scerJarflable co of sysfeni' art aall permanently installed luminaries in garages, laundry rooms, closets greater than 70 sgtd �itilityy rooms are high�effi aey a d controlled by a �_ manual-on occupant sensor. ,c• r,cv---f'y �aIL §150(k)9: Permanently installed lighting that is internal to cabinet sF' e[jr oar iofe han watts ower pe linear foot of illuminated cabinet. o-- GGNS 01 FBI I'J n TE - EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 20 3-0 - " : To IF Page 15 of 48 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Lot 242 - The Hideaway 1511512013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. LA U Io PA& SARFETYp u EDN E --- BY EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15715:01:10 /D: Page 16 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #1 Floor Area 1,377 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 915 14,608 Return Vented Lighting 0 Return Air Ducts 843 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 843 TOTAL SYSTEM LOAD 1 16,294 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 70,000 1,565 148 11,241 Total Output Btuh 70,000 Output Btuh/s ft 50.8 552 Cooling S stem 0 Output per System 88,000 0 0 0 Total Output Btuh 88,000 1,565 0 Total Output Tons 7.3 552 Total Output Btuh/s ft 63.9 Total Output s ft/Ton 187.8 12,346 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox SL280UH090XV60C• 71,929 5,866 70,000 Airflow cfm/s ft 0.58 Airflow cfm/Ton 109.1 Outside Air % 0.0 % Total Adjusted System Output 71,929 5,866 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 70,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 OF 67 OF 140 OF 140 OF Heating Coil Supply Fan 800 cfm 139 a F ROOM 68 OF 4 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F outside Air 0 cfm 76/65OF 76/65°F 59/58°F 59/58°F TA � G1 DEP-T- Cooling Coil Supply Fa 13UILp1NG & SQV 60 / 58 OF 800 cfm PPR - 10, FOR CO 75/64°F DATE EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15715:01:10 /D: Page 17 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 System Name Floor Area Hvac #2 592 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 747 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible -atent CFM Sensible Output per System 52,000 10,824 587 143 5,735 Total Output Btuh 52,000 0 Output Btuh/s ft 87.8 625 282 Cooling System 01 0 Output per System 66,000 0 0 0 0 Total Output Btuh 66,000 1,148 587 -1,148 Total Output Tons 5.5 625 282 Total Output Btuh/s ft 111.5 Total Output s ft/Ton 107.6 1 13,222 5,150 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Lennox SL280DF07OV36A-' 51,103 7,229 52,000 Airflow cfm/s ft 2.03 Airflow cfm/Ton 218.2 52,000 Jan 1 AM Outside Air % 0.0% Total Adjusted System Output 51,103 7,229 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 105 OF 106 OF Outside Air 0 cfm Heating Coil Supply Fan ° 106 F 1,200 cfm ROOM 68 OF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak �+-- 112/78°F 75/65°F 60/59°F' ()UITq f F LA PT. _ � Outside Air {� �r 0 cfm Supp Fan / Cooling Coil 1,20, cfm FOR CONSTRUCTI 61 60°F 57.0% R OM 75/65°F ATE ----'—BY 75/64°F EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15715:01:10 /D: Page 18 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #3 Floor Area 1,132 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 799 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEW COIL HTG. PEAK Heating System Sensible -atent CFM Sensible Output per System 70,000 12,868 1,322 134 10,203 Total Output Btuh 70,000 0 Output Btuh/s ft 61.8 743 501 Cooling System 01 0 Output per System 88,000 0 0 0 0 Total Output Btuh 88,000 0 1,322 0 Total Output Tons 7.3 743 501 Total Output Btuh/s ft 77.7 Total Output s ft/Ton 154.4 1 14,354 11,205 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox SL280UH090XV60C' 72,268 5,359 70,000 Airflow cfm/s ft 0.71 70,000 Jan 1 AM Airflow cfm/Ton 109.1 Outside Air % 0.0% Total Adjusted System Output 1 72,2681 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,3591 aug 3M Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF No Outside Air 0 cfm 67 OF 67 OF 140 OF 140 OF Supply Fan Heating Coil 139 OF 800 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76/64°F 76/65°F 59/58°F 59/58°F c c Cooling Coil Supply Fan 60 / 58 OF 800 cfm 56.1 ROOM 75/64°F EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15715:01:10 /D: Page 19 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #4 Floor Area 1,529 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 2,032 30,281 Return Vented Lighting 0 Return Air Ducts 1,748 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1,748 TOTAL SYSTEM LOAD 1 33,777 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 70,000 1,916 263 19,834 Total Output Btuh 70,000 Output Btuh/s ft 45.8 975 Cooling System 0 Output per System 88,000 0 0 0 Total Output Btun 88,000 1,916 0 Total Output Tons 7.3 975 Total Output Btuh/s ft 57.6 Total Output s ft/Ton 208.5 21,784 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox SL280UH090XV60C' 71,399 6,911 70,000 Airflow cfm/s ft 0.52 Airflow cfm/Ton 109.1 70,000 F Jan 1 AM Outside Air % 0.0% Total Adjusted System Output 71,399 6,911 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3P ml Outside Air cfm/s ft 0.00 Note: values above iven at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 OF 67 OF 140 OF 140 OF Heating Coil Supply Fan 139 OF 800 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 77 / 65 OF 77 / 65 °F 59 / 58 °F 59 586 Ty OF LA ,QUI NTA ¢ L IN 8 S DEPT. ED Cooling Coil 5upply 800 cfm n FOR CONSTRUCTION s / 59 OF 56.8 % [ROOM DATE ----- BY / 64 OF EnergyPro 5.1 by EnergySoR User Number: 3665 Run Code: 2013-05-15T15:01:10 /D: Page 20 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #5 Floor Area 1,061 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 934 14,904 Return Vented Lighting 0 Return Air Ducts 860 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 860 TOTAL SYSTEM LOAD 1 16,624 PEAK COIL HTG. PEAK Heating System '-atent CFM Sensible Output per System 70,000 1,452 129 9,807 Total Output Btuh 70,000 Output Btuh/s ft 66.0 482 Cooling System 0 Output per System 88,000 0 0 0 Total Output Btuh 88,000 1,452 0 Total Output Tons 7.3 482 Total Output Btuh/s ft 82.9 Total Output s ft/Ton 144.7 10,770 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox SL280UH090XV60C' 72,083 5,659 70,000 Airflow cfm/s ft 0.75 Airflow cfm/Ton 109.1 Outside Air % 0.0% Total Adjusted System Output 72,083 5,659 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 70,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 OF 67 OF 140 OF 140 OF G Heating Coil Supply Fan o 800 cfm 139 F ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76 / 65 OF 76/65°F 59/58°F 59/58°F c t T F U I I I I Cooling Coil Supply Fan BUILDING & SA:EN DEPT. 6 /580F 800 cfm AP P RC,V D FOR COJ tvotpu M 75 64 OF I DATE — --- —J 1 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15T15:01:10 /D: Page 21 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #6 Floor Area 832 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 807 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEW COIL HTG. PEAK Heating System Sensible _atent CFM Sensible Output per System 70,000 12,983 1,025 118 8,959 Total Output Btuh 70,000 0 Output Btuh/s ft 84.1 749 440 Cooling System 0 0 Output per System 88,000 0 0 0 0 Total Output Btuh 88,000 0 1,025 0 Total Output Tons 7.3 1 749 440 Total Output Btuh/s ft 105.8 Total Output s ft/Ton 113.5 1 14,481 9,840 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox SL280UH090XV60C' 72,675 4,795 70,000 Airflow cfm/s ft 0.96 Airflow cfm/Ton 109.1 Outside Air % 0.0% Total Adjusted System Output 72,675 4,795 70,000 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 10 Outside Air 0 cfm 67 OF 67 OF 140 OF /-� 140 OF f =� `� i JH Heating Coil Supply Fan o 800 cfm 139 F ROOM a 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm AL 76/64°F 76/64°F 59!58°F 59/58°F ° r �rl�.� c Supply Fan BUILDji'�G & SAFETY DEP60/5 . OF Cooling Coil 800 cfm Oil ?66� u�'t"i 75/6 °F DATE _- EnergyPro 5.1 by EnergySoff User Number: 3665 RunCode: 2013-05-15T15:01:10 /D: Page 22 of 48 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #7 Floor Area 1,163 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 685 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible _stent CFM Sensible Output perSystem 70,000 11,117 1,553 141 10,748 Total Output Btuh 70,000 0 Output Btuh/s ft 60.2 642 528 Cooling System 0 0 Output perSystem 88,000 0 0 0 0 Total Output Btuh 88,000 0 1,553 0 Total Output Tons 7.3 1 642 528 Total Output Btuh/s ft 75.7 Total Output s ft/Ton 158.6 12,401 11,804 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Lennox SL280UH090XV60C' 71,959 5,753 70,000 Airflow cfm/s ft 0.69 70,000 Jan 1 AM Airflow cfm/Ton 109.1 Outside Air % 0.0% Total Adjusted System Output 71,959 5,753 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 67 OF 67 OF 140 OF 140 OF f C�� G Heating Coil Supply Fan 139 OF 800 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside AirDEPT. 0 cfm 76/65°F .4 76!65°F 59/58°F 59/58°F � O o Cooling Coil Supply Fan BUILDING & 60 / 58 OF 800 cfm APP �O`gC FORCON ��' �i ��++++ �I��t1l1//QOM 5/64°F RV 4 3 DA I t EnergyPro5.1 by EnergySoff User Number: 3665 RunCode: 2013-05-15T15:01:10 /D: Page 23 of 48 ROOM LOAD SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #1 Floor Area 1,377 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 1 Master Suite & Bath 1 915 14,608 1,565 915 14,605 1,565 148 11,241 LJA � l J y i 14 i 1 BUILC;\l6 FQ ; Co STRU` T ' Total includes ventilation load for zonal systems. PAGE TOTAL915 09 1,565 48 11,241 i GATE — TOTAL " 915 14 6.OB.�,p --- 4481 11,241 EnemyPro 5.1 by Ene Soft User Number: 3665 RunCode: 2013-05-15715:01:10 ID: Pa a 24 of 48 ROOM LOAD SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #2 Floor Area 592 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 2 Sitting Room 1 747 10,824 587 747 10,824 587 143 5,735 cl-rf LA UU11IN T• BUILT ANG SAFE, I y DEF _ P P R OW:r .0 CC NSTRU CTIO ' Total includes ventilation load for zonal systems. PAGE TOTALATE _ 747 10 8 8J L o �-�. TOTAL * 747 10,824 587 43 5,735 143 5,735 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15T15:01:10 /D: Page 25 of 48 ROOM LOAD SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #3 Floor Area 1,132 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLINC PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 3 Game Room & Bedroom 1 799 12,868 1,322 799 12,86E 1,322 134 10,203 sa 111 ! I y U Lir 4 UJI I BUIL DINC; & 6Art. Iyy UC r 1. ' Total includes ventilation load for zonal systems. F " R rnINISTRUCTIUN PAGE TOT L 799 12,81~9 1,322 TOTA ;DATE 799 12 1,322 t 13 10,203 13 10,203 EnergyPro 5.1 by EnemySoft User Number: 3665 Run Code: 2013-05-15715:01:10 /D: Page 26 of 48 ROOM LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 System Name Floor Area Hvac #4 1,529 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 4 Great Room & Kitchen, 8 1 2,032 30,281 1,916 2,0321 30,2811 1,916 263 19,834 PAGE TOTAL I TOTAQJATE _ I'T ED 2,032 30,281 1,916 63 19,834 032 3R0, 91 16 t63 19,834 ROOM LOAD SUMMARY Project Name Lot 242 - The Hideaway Date 5/15/2013 System Name Hvac #5 Floor Area 1,061 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 5 Dining, Laundry & Pantry 1 934 14,904 1,452 934 14,904 1,452 129 9,807 C I OLA (JUIN BUIL C ING & SAFETY DE APPf:1 (-)\/I=� STRU' TION ' Total includes ventilation load for zonal systems. PAGE TO, AL 934 TOTIALCATE 14,904 1,452 14,904 145 029 A9807 29 9,807 EnergyPro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15715:01:10 /D: Page 28 of 48 ROOM LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 System Name Floor Area Hvac #6 832 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM I Sensible Latent CFM I Sensible Zone 6 Home Gym, Entry, Guest 1 807 12,983 1,025 807 12,98.? 1,0251 1181 8,959 BUILIDINU Z' ,* PPI "aE TOT6 b (101 TOTAL' 4 � S?80?kt CiT1i2 8 1, L 5 118 8, 959 807 12,983 1 1,45 118 8,959 Total includes ventilation load for zonal systems. i BY Ene Pro 5.1 by Ene Soft User Number: 3665 RunCode: 201316'WI5:01:10 Page 29 o/48 ROOM LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 I Hvac #7 1,163 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Zone 7 Bedroom 1 & 3 1 685 11,117 1,553 685 11,117 1,553 141 10,748 P Total includes ventilation load for :pT" FOI; !✓Q�� LGE TOTAL TOTAL* y PSATE 685 11,117 1, 5.3 141 10,748 685 11 117 141 107481 ROOM HEATING PEAK LOADS Project Name Lot 242 - The Hideaway Date 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite & Bath Floor Area 1,377.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X= A AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-21 Wall 661.1 0.0690 42 1,916 Sierra Pacific Windows & Doors 173.9 0.3300 42 2,410 Alumn French Door 116.0 0.3700 42 1,803 R-38 Roof Attic 1,377.0 0.0250 42 1,446 Slab-On-Grade perim = 106.0 0.0230 42 102 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,377 X[l Area another room I I '1000 Y, X03,4 ' 0Qight + IACH PPRO\ APPROVE.,,,, {{ Page TOtal �6i0�] �X� AT /E 7.677 = 3,564 Ce TOTAL HOURLY HEAT LOSS FOR ROOM Ur1CaNSTRY 11,241 T Energ Pro 5.1 by Energ Soft User Number: 3665 RunCode: 2013- 5- V17ID: Page 31 of 48 ROOM HEATING PEAK LOADS Project Name Lot 242 - The Hideaway ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction R-21 Wall Weiland Door R-38 Roof Attic Slab -On -Grade DESIGN CONDITIONS Sitting Room Time of Peak 592.0 ft2 Outdoor Dry Bulb Temperature 68 OF Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 194.0 0.0690 184.0 0.3700 592.0 0.0250 perim = 165.0 0.0230 Items shown with an asterisk (') denote conduction through an Infiltration:[ 1.00 X 1.064 X C Schedule Air Sensible I Fraction TOTAL HOURLY HEAT LOSS FOR ROOM OT *F 42 42 = 42 42 Total 5/15/2013 Jan 1 AM 26 OF Dli�.O SAFETY DEMI - — X 6( ] X 42 Ceiling -1 eighMNOtc,14,i-�JDTION AT 3665 Run Code:2013-05-15715:01:10 /D: Btu/hr 562 2,859 622 159 4,203 1,532 5 735 32 of 48 ROOM HEATING PEAK LOADS Project Name Lot 242 - The Hideaway Date 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Game Room & Bedroom 1 Floor Area 1,132.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X x to DING A F+ei(ii�gLHai9titi5 U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT`F Btu/hr = 2,162 = 504 = 208 = 2,996 = 1,189 = 213 = = = = = = = = = = = = = = = = = = = = = = = = - 7,273 42 = 2,930 R-21 Wall 746.2 0.0690 42 Wood Door 24.0 0.5000 42 Sierra Pacific Windows & Doors 15.0 0.3300 42 Alumn French Door 192.8 0.3700 42 R-38 Roof Attic 1,132.0 0.0250 42 Slab-On-Grade perim = 221.0 0.0230 42 ., t .�x throElor surface BUIL 1.064 X32 X Area �- A A� n�R.IT %.1i Y_i' r c another room &SAFETY IAto- ,X I I iON wro,��, DEPT. Page Total / 60 J X AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 x Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM DATE ____---b 7 10,203 ---------------- EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15715:01:10 /D: Page 33 of 48 ROOM HEATING PEAK LOADS Project Name Lot 242 - The Hideaway Date 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room & Kitchen, Breakfast Floor Area 1,529.0 ft2 Indoor Dry Bulb Temperature 68 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value 0.0690 X 0.5000 X 0.3700 X 0.3300 X 0.0250 X 0.0230 X X X OT'F = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-21 Wall 977.1 X 32.0 X 608.8 X 42 2,832 Wood Door 42 672 Weiland Door 42 9,461 Sierra Pacific Windows & Doors 87.1 X 42 1,207 R-38 Roof Attic 1,529.0 X 42 1,605 Slab-On-Grade perim = 103.0 X X X 42 99 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X DEPT. Page 6 X I%Y Total Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior X 1,59 Area sElldacel�to rs X� C ilih� ��Tr anoither roomilFETY �\ fk v y0p0; EXs l 0.193'"/ Hftht`�J I F"AEW f 15,877 = 3,957 42 AT TOTAL HOURLY HEAT LOSS FOR ROOM a 19,834 Energ Pro 5.1 by EnergySoft User Number: 3665 Run Code: 2013-05-15715:01:10 /D: Page 34 of 48 ROOM HEATING PEAK LOADS Project Name Lot 242 - The Hideaway Date 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining, Laundry & Pantry Floor Area 1,061.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X U � 97� AT °F a c = = _ = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-21 Wall 656.3 X X 0.0690 42 1,902 Wood Door 24.0 0.5000 42 504 Alumn French Door 184.0 X 0.3700 42 2,859 Sierra Pacific Windows & Doors 40.7 X 0.3300 42 564 R-38 Roof Attic 1,061.0 X 0.0250 42 1,114 Slab-On-Grade perim = 121.0 X 0.0230 42 117 X X X X X X X X X X X X X X X X X X X X X X X X through an inte for u?foace UII X 1, 61 X Area tda other room\ O IntC; & SAFETY In— k1Q.00, X lq 0. FOIR9Cc�NSTI�U-'TION Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction N A W age Total DEPT. 60 J X °T 7,060 = 2,746 TOTAL HOURLY HEAT LOSS FOR ROOM 9,807 EnergyPro 5.1 by EnergySoft User Number: 3665 RunCode: 2013-05-15T15:01:10 ID: Page 35 of 48 ROOM HEATING PEAK LOADS Project Name Lot 242 - The Hideaway Date 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Home Gym, Entry, Guest Room Floor Area 832.0 ft2 Indoor Dry Bulb Temperature 68 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value X 0.0690 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 1 bf AT 'F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-21 Wall 663.8 42 1,924 Sierra Pacific Windows & Doors 174.2 X 0.3300 42 2,414 Alumn French Door 96.0 X 0.3700 42 1,492 R-38 Roof Attic 832.0 X 0.0250 42 874 Slab-On-Grade perim = 106.0 X 0.0230 X 42 102 X X X X X X X X X X X X X X X X X X X X X X X X A"'�/ Ai-- M kJ(V to another room UIDIN - �- ��FETY I &e-1.OAO,X )�0.347 Ceili. 9 Heiight'�S"rpj Cpl F-Ur !'� through an inter, or Crface X 8.32 X Area Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction it v� W Page Total DEPT. 1.�J'sAnT J X IU AT 6,806 42 = 2,153 TOTAL HOURLY HEAT LOSS FOR ROOM Y� BY 8 959 EnergyPro 5.1 by EnergYSoft User Number: 3665 RunCode: 2013-05-15715:01:10 /D: Page 36 of 48 ROOM HEATING PEAK LOADS Project Name Lot 242 - The Hideaway Date 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 1 & 3 Floor Area 1,163.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X px„ to, E3D►! Ceili6gZHeight-,�I�CACM��' U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ml 4. ATF Btu/hr = 3,091 = 1,764 = 1,221 = 1,661 = = = = = = = = = = = = = = = = = = = = = = = = = = _ 7,738 42 T R-21 Wall 1,066.7 0.0690 42 Sierra Pacific Windows & Doors 127.3 0.3300 42 R-38 Roof Attic 1,163.0 0.0250 42 R-22 Floor Crawlspace 1,163.0 0.0340 42 _ -T-W n z: I anotht er room i✓IiV�a SAFETY X800 X ��0 l_1 A NT Pa a Total DEF 9 60 �C t t through an interior slace X 1,163 Area Items shown with an asterisk (') denote conduction Infiltration: 1.00 X Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM DA I b--- 10,748 EnergyPro 5.1 by EnergySoft User Number.- 3665 Run Code: 2013-05-15T15:01:10 /D: Page 37 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite & Bath Outdoor Dry Bulb Temperature 112 OF Floor Area 1,377.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-21 Wall R-21 Wall R-21 Wall R-38 Roof Attic Orientation (E) (1/10 (N) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = 485.7 0.0690 33.0 103.0 0.0690 26.0 72.4 0.0690 33.0 1,377.0 0.0250 56.0 0.0 17.4 34.6 0.01 17.4 34.6 0.0 17.4 9.7 X 9.7X 19.5 X 19.5 X 34.6 0.0 17.4 34.6 I J I J= 34.6 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Sierra Pacific Casement (W22) Sierra Pacific Casement (W21) Sierra Pacific Casement (W20) Sierra Pacific Casement (W19) Sierra Pacific Casement (W18) Sierra Pacific Casement (W17) Sierra Pacific Casement (W16) Sierra Pacific Casement (W15) Sierra Pacific Casement (W14) Internal Gain Orientation (E) (E) (E) (E) (E) (E) (E) (E) (E) Area X X X X X X X X X GLF + + + + + + + + + Area GLF = = = = = = = = 0.0 17.4 9.7, X 34.6 0.0 17.4 19.3; X 19.3 X 19.3;X 19.3; X 34.6 0.0 17.4 34.6 0.0 17.4 34.6 0.01 17.4 34.6 0.0 17.4 9.7 X 9.7X 19.5 X 19.5 X 34.6 0.0 17.4 34.6 0.0 17.4 34.6 0.0 17.4 = 200 Page Total Btu/hr 1,106 185 165 1,928 3,383 Btu/hr 335 667 667 667 667 335 335 674 674 5,024 Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.= 230 Equipment 0.0 Dwelling Unit X 1.6001 Btu = 0 Infiltration: 1.064 X 0.89 X 85.26 X 37 = 2,996 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM �R, �,� 14,608 CET' OF L/Al klult 14 i IV • Latent Gain ,�,�- .a. •.AFFTY DEPT. Btu/hr Occupants 77:11.0 Occupants X _..,,..s--, r"200£ fgtuh/ cc.. = 200 Infiltration: 4,771 X 0.89 X 85.26 X �0003761N`'TRUCTION 1,365 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM - 1,5651 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite & Bath Outdoor Dry Bulb Temperature 112 OF Floor Area 1,377.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Fage Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Exterior French Door (D 16) (S) 0.0 X 17.0 + 116.0 X 17.1 = 1,985 Sierra Pacific Casement (W13) (l9 0.0 X 17.4 + 28.6 X 34.6 = 989 X + X – X + X – X + 'X – X + €X – X + '.X – X + °X = X + X = Page Total 2,974 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.89 X 85.26 X 37 = 2,996 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM �t (� �. U UII-4 1 ` 14,608 DRNC & ,,'?FET` D"I"' Latent Gain D Btu/hr Occupants 1.0 OccupantV 1-0 = 200 tELA Im�2vOv�tut4c. FOR Infiltration: 4,771 X 0.89 X 0.00376 = 1,365 Air Sensible CFM AW�— BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,565 EnemvPro 5.1 by EnerqvSoft User Number. 3665 RunCode: 2013-05-15T15:01:10 ID: Page 39 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Sitting Room Outdoor Dry Bulb Temperature 112 OF Floor Area 592.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (S) 41.0 X 0.0690 X 38.0 = 108 R-21 Wall (tM 153.0 X 0.0690 X 55.0 = 581 R-38 Roof Attic (N) 592.0 X 0.0250 X 77.0 = 1,140 X X = X X = X X = X X = X X = X X = Page Total 11828 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Pkt Slider Door (D 17) (S) 0.0 X 20.3 + 95.0 X 26.0 = 2,469 Pkt Slider Door (D 18) 0.0 X 20.3 + 89.0 X 58.9 = 5,238 X + X - X + X - X + IX = X + X - X + X = X + X = X +1 X = Page Total 7,708 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 0.89 X 36.66 X 37 = 1,288 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROO I Ani IINITA 1 10,824 Latent Gain BUILDINGSAFET`���DEPT. Btu/hr Occupants ^e& 0.0 Occupants p p l� �j2 0 at h/occ. = 0 r NSTRUCTION Infiltration: 4,771 X 0.89 X 36. 6 X 0.00376 = 587 Air Sensible CFM ELA AW DATE _---- BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 587 EnerqvPro 5.1 by EnerSott User Number: 3665 RunCode: 2013 -OS -15715:01:10 /D: Pa a 40 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Game Room & Bedroom 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,132.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor LTD' Btu/hr R-21 Wall (N) 242.0 X 0.0690 X 23.0 = 384 Wood Door (N) 24.0 X 0.5000 X 23.0 = 276 R-21 Wall (E) 253.2 X 0.0690 X 33.0 = 577 R-21 Wall (VIO 251.0 X 0.0690 X 33.0 = 572 R-38 Roof Attic (N) 1,132.0 X 0.0250 X 56.0 = 1,585 X X = X X = X X = X X = Page Total 3,393 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Sierra Pacific Casement(W24) (E) 0.0 X 17.4 + 15.0: X 34.6 = 519 Double French Door (D 13) (E) 0.0 X 17.0 + 96.8 X 32.5 = 3,145 Double French Door (D04) W 0.0 X 17.0 + 48.0 X 32.5 = 1,559 Double French Door(D05) 0.0 X 17.0 + 48.0 X 32.5 = 1,559 X + X = X + X - X + X - X + X = X +1 X = Page Total 6,782 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.89 X 70.09 X 37 = 2,463 Air Sensible CFM ELA DT (-,w-Ly OF LA QUINTA TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM I ��, til sz, -,,AF= DEET. 12,868 ROVED Btu/hr Latent Gain Occupants ,r- �' (�� 1.0 Occupants X BCH W115I )oo�61 /occ. = Occupants 200 Infiltration: 4,771 X 0.89 X 70.09,. 0.00376=BY 1,122 Air Sensible CFM AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,322 EnerqvPro 5.1 by EnemySoft User Number: 3665 RunCode: 2013-05-15715:01:10 ID: Page 41 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room & Kitchen, Breakfast Outdoor Dry Bulb Temperature 112 OF Floor Area 1,529.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Dally Range: 34 OF Opaaue Surfaces R-21 Wall Wood Door R-21 Wall R-21 Wall R-38 Roof Attic Orientation (N) (E) (IM (N) Area X X X X X X X X X U -Factor X X X X X X X X X "LTD' = = = = = = = = 268.7 0.0690 23.0 32.0 0.5000 23.0 512.8 0.0690 33.0 195.6 0.0690 33.0 1,529.0 0.0250 56.0 17.4 17.4 0.0 17.0 32.5 0.0 17.0 328.8: X 80.0i X 32.5 0.0 J I= 0.0 17.4 Forge Total Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration Pocket Slider (D02) Sierra Pacific Fixed (W32) Sierra Pacific Fixed (W31) Sierra Pacific Fixed (W48) Sierra Pacific Fixed (W49) Pocket Slider (D20) Pocket Slider (D 19) Pocket Slider (D21) Sierra Pacific Fixed (W36) Oripntatinn (N) (N) (N) (N) (N) (E) (E) (E) (E) Btu/hr 426 1,168 445 2,141 1 4,5481 Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area GLF = = = = = = = = = 0.0 17.0 120.0 X 3.6 X 23.5; X 3.6; X 3.6 X 80.0' X 17.0 0.0 17.4 17.4 0.0 17.4 17.4 0.0 17.4 17.4 0.0 17.4 17.4 0.0 17.0 32.5 0.0 17.0 328.8: X 80.0i X 32.5 0.0 17.0 32.5 0.0 17.4 3.6 X 34.6 U1 I y k-111 y--`"� `�` 30,281 Page Total Btu/hr 2,046 63 408 63 63 2,599 10,681 2,599 124 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.89 X 94.68 X 37 = 3,327 Air Sensible CFM ELA AT -s ,,I'!r +I I I i! TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM U1 I y k-111 y--`"� `�` 30,281 BUILDING 8:iHi-� Latent Gain �• ;-,; �,"+,� Jap Btu/hr Occupants 2.0 OCCu ants X � � �� p -��n r,l�:l`tc TP2,00°' G. _ 400 Infiltration: 4,771 X 0.89 X 94.680 X 0.00376 = Air Sensible CFM ELA D'f j[ _0W_ BY 1 1,5161 I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.9161 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room & Kitchen, Breakfast Outdoor Dry Bulb Temperature 112 OF Floor Area 1,529.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Sierra Pacific Fixed (W35) (E) 0.0 X 17.4 + 3.6 X 34.6 = 124 Sierra Pacific Fixed (W34) (E) 0.0 X 17.4 + 3.6: X 34.6 = 124 Sierra Pacific Fixed (W33) (E) 0.0 X 17.4 + 3.6 X 34.6 = 124 Sierra Pacific Casement (W12) (VIO 0.0 X 17.4 + 12.8 ; X 34.6 = 443 Sierra Pacific Casement (W11) (VV) 0.0 X 17.4 + 12.8 X 34.6 = 443 Sierra Pacific Casement (W10) (tM 0.0 X 17.4 + 12.8: X 34.6 = 443 X + iX = X + X = X 1 +1 X1 = Page Total 1,701 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.89 X 94.68 X 37 = 3,327 Air Sensible CFM ELA (-ITY OF LA OUINTA TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOR i „r,intr~ Q, cr,cr-TV nF 30,281 Latent Gain APPROVED Btu/hr Occupants 2.0 Occupants94.8 FOR CONSTRl StUI�/occ. = 400 Infiltration: 4,771 X 0.89 X Xr 0.00376 - BY _ 1,516 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,916 EnemvPro 5.1 by EnemySoft User Number: 3665 Run Code: 2013-05-15715:01:10 /D: Page 43 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining, Laundry & Pantry Outdoor Dry Bulb Temperature 112 OF Floor Area 1,061.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor tCLTD' Btu/hr R-21 Wall (N) 153.0 X 0.0690 X 23.0 = 243 Wood Door (N) 24.0 X 0.5000 X 23.0 = 276 R-21 Wall (E) 57.0 X 0.0690 X 33.0 = 130 R-21 Wall (tM 446.3 X 0.0690 X 33.0 = 1,016 R-38 Roof Attic (N) 1,061.0 X 0.0250 X 56.0 = 1,485 X X = X X = X X = X I X I= Page Total 3,150 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Double French Door (D03) (E) 0.0 X 17.0 + 160.0 X 32.5 = 5,198 Single French Door (D22) (lM 0.0 X 17.0 + 24.0; X 32.5 = 780 Sierra Pacific Casement (W09) (tM 0.0 X 17.4 + 7.01 X 34.6 = 242 Sierra Pacific Casement (W08) (lM 0.0 X 17.4 + 14.3 ; X 34.6 = 494 Sierra Pacific Fixed (W07) (tM 0.0 X 17.4 + 9.7 X 34.6 = 335 Sierra Pacific Fixed (W06) (tM 0.0 X 17.4 + 9.7 X 34.6 = 335 X + X - X + =X = X + X - Page Total 7,385 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = 460 Equipment 1.0 Dwelling Unit X ------x;600°-Btui = 1,600 tiyU; LAQUINTA Infiltration: 1.064 X 0.89 X 65.70 X BU0-7 ''!r & SAFETY DEPT. 2,309 Air Sensible CFM ELA AT r-rZrr � � rc�-rir-i � FR FOR `y'1N',G, TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,904 Latent Gain i DATE BY Btu/hr Occupants 2.0 Occupants X ------20: = 400 Infiltration: 4,771 X 0.89 X 65.70 X 0.00376 = 1,052 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,452 EneMVPrc, 5.1 bV EneMVSoft User Number: 3665 RunCode: 2013-05-15T15:01:10 ID: Page 4of 48 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 1 5/15/2013 ROOM INFORMATION I DESIGN CONDITIONS Room Name Home Gym, Entry, Guest Room Outdoor Dry Bulb Temperature 112 OF Floor Area 832.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 of I Outdoor Dailv Rancte: 34 OF Opaque Surfaces R-21 Wall R-21 Wall R-21 Wall R-38 Roof Attic Orientation (S) (N) Area X X X X X X X X X U -Factor X X X X X X X X X :LTD' = = = = = = = = 343.2 0.0690 31.0 145.0 0.0690 44.0 175.6 0.0690 38.0 832.0 0.0250 77.0 0.0 20.9 20.9 0.0 20.9 29.0 , X 20.9 0.0 20.9 8.2: X 8.2: X 20.9 0.0 20.9 20.9 J= 20.9 8.2i X Fage Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Sierra Pacific Casement (W05) Sierra Pacific Fixed (W05A) Sierra Pacific Casement (W04) Sierra Pacific Fixed (W04A) Sierra Pacific Casement (W03) Sierra Pacific Fixed (W28) Sierra Pacific Fixed (127) Sierra Pacific Fixed (W26) Sierra Pacific Fixed (W25) Orientation (N) (N) (N) (N) (N) (N) (N) (N) (N) Area X X X X X X X X X GLF + + + + + + + + + Area 29.0': X GLF = = = = = = = = = 0.0 20.9 20.9 0.0 20.9 7.0t X 20.9 0.0 20.9 29.0' X 7.0 X 20.9 0.0 20.9 20.9 0.0 20.9 29.0 , X 20.9 0.0 20.9 8.2: X 8.2: X 20.9 0.0 20.9 20.9 0.0 20.9 8.2i X 20.9 0.0 20.9 8.21 X 20.91 Page Total Internal Gain Occupants 1.0 Occupants X 230Btuh/occ. _ Equipment 0.0 Dwelling Unit X�,20o Bt f I r Q 1 NTA Infiltration: 1.064 X o.as X 51.52 X 37..DING & SAFETY DEPT. Air Sensible CFM ELA AT APPROVED 1 FOR CONSTRUCTION TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain I DATE BY Occupants 1.0 Occupants X 1 200 Btuh/occ. _ Infiltration: 4,771 X 0.89 X 51.52 X 0.00376 = Air Sensible CFM ELA AW ITOTAL HOURLY LATENT Btu/hr 734 440 460 1,6021 3,236 Btu/hr 607 147 607 147 607 172 172 172 172 2,803 Btu/hr 230 0 1,811 1Z983 Btu/hr 200 825 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Home Gym, Entry, Guest Room Outdoor Dry Bulb Temperature 112 OF Floor Area 832.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor ^:,LTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Single French Door (DO8) (E) 0.0 X 20.9 + 24.0 X 46.8 = 1,123 Double French Door(DO6) (E) 0.0 X 20.3 + 48.01 X 43.4 = 2,084 Double French Door (DO6) (S) 0.0 X 20.3 + 48.01 X 26.0 = 1,248 Sierra Pacific Fixed (W29) (S) 0.0 X 20.9 + Y 8.2 X 27.3 = 224 Sierra Pacific Fixed (W30) (S) 0.01 X 20.9 + 8.2 X 27.3 = 224 X + X - X + X - X + X - X + X - Page Total 4,903 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ.= 230 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 0.89 X 51.52 X 37 = 1,811 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM CZ983 GI I Y 01- LA QUIN IA Latent Gain Occupants 1.0 Occupants X RI -III 200 ING &SAFETY DE. Btuh Com, o` ,� r=� $tu hr 200 Infiltration: 4,771 X 0.89 X 51.52 X 0.00376 I FOR CONSTRUCTlO 825 Air Sensible CFM ELA AW DATE BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM i 025 Ene Pro 5.1 by EnerqvSoft User Number: 3665 Run Code: 2013-05-15715:01:10 /D: Page 46 of 48 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 1 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Surfaces R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-38 Roof Attic R-22 Floor Craw/space Bedroom 1 & 3 Outdoor Dry Bulb Temperature 1,163.0 ft2 Outdoor Wet Bulb Temperature 75 OF Outdoor Daily Ranqe: Orientation (N) (E) (S) (tM Area X X X X X X X X X U -Factor X X X X X X X X X :LTD' = = = = = = = = = 174.4 0.0690 23.0 355.2 0.0690 33.0 164.1 0.0690 26.0 373.0 0.0690 33.0 1,163.0 0.0250 56.0 1,163.0 0.0340 19.0 6.91X 19.2: X 34.6 0.0 17.4 34.6 0.0 17.4 6.9 X 34.6 0.0 Fage Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Sierra Pacific Casement (W46) Sierra Pacific Casement (W45) Sierra Pacific Casement (W44) Sierra Pacific Casement (W43) Sierra Pacific Casement (W42) Sierra Pacific Fixed (W41) Sierra Pacific Casement (W40) Sierra Pacific Casement (W39) Sierra Pacific Casement (W38) I Internal Gain OriPntatinn (N) (N) (N) (E) (E) (E) (E) (E) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + +1 Area GLF = = = = = = = = = 0.0 17.4 5.2 X 5.2{X 17.4 0.0 17.4 17.4 0.0 17.4 5.2'X 17.4 0.0 17.4 6.9`X 34.6 0.0 17.4 6.91X 19.2: X 34.6 0.0 17.4 34.6 0.0 17.4 6.9 X 34.6 0.0 17.4 6.9 X X 34.6 0.0 1 17.4 6.9 17.4 2.0 Occupants X 230 Btuh/occ.. 0.0 Dwelling Unit X 1 1,600 Btu Infiltration: 1.064 X 0.89 X 72.01 X 37 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 2.0 Occupants X Infiltration: 4,771 X 0.89 X 72.01 X C Air Sensible CFM ELA AW Page Total I nirmf a& SA! ETY DEPT. A 20Qi �tuh/occ. _ r-li I t��VED FOR CONSTRUCTION 112 OF 78 OF 34 OF Btu/hr 277 809 294 849 1,628 751 4,609 Btu/hr 90 90 90 239 239 664 239 239 120 2,009 Btu/hr 460 0 2,531 11,117 Btu/hr 400 1.153 I DATE BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM t RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lot 242 - The Hideaway 5/15/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 1 & 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,163.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor :,LTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Sierra Pacific Casement (W37) .(S) 0.0 X 17.4 + 29.0. X 17.4 = 505 Sierra Pacific Casement (W47) (W) 0.0 X 17.4 + 29.0+ X 34.6 = 1,003 X + X - X + X = X + X - X + X - X + X - X + X - X + X - Page Total 1,508 Internal Gain Btu/hr Occupants 2.o Occupants X 1 230 Btuh/occ. = 460 Equipment 0.0 Dwelling Unit X 1 1,600 Btu = 0 Infiltration: 1.064 X 0.89 X 72.01 X 37 = 2,531 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,117 I GI i Y U QUINTA Latent Gain Occupants I RI ri ni.lr &SAFETY DEPT. tu /occ. = 2.0 Occupants XT200�B' Btu/hr 400 Infiltration: 4.771 X o.8s X 72.01 X 0.Q037s FOR CONSTRJCTION 1,153 Air Sensible CFM ELA Avv I DATE RY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,5531 EnemvPro 5.1 by EnemySoft User Number: 3665 Run Code: 2013-05-15T15:01:10 /D: Pa a 48 of 48 Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766.8777 Fax (95I) 766-8778 April 10, 2013 Peter Jacobs Homes P.O. Box 356 Project No. 544-13079 M Ay 3 1 2013 13-04-127 La Quinta, California 92247 1'4 Project: Proposed Custom Residence RECEIVED 80-221 Via Pessaro - Lot 242 The Hideaway La Quinta, California MAY 2 4 2013 Subject: Geotechnical Update CITY OF LA QU11\1TA COMMUNITY DEVELOPMENT Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated September 22,2000; File No. 07117-10, Report No. 00-09-772 Report of Testing and Observation During Rough Grading prepared by ESS dated August 28, 2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observation During Rough Grading prepared by Sladden Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647 As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of osed custom residence. The project site is located at 80-221 Via Pessaro (identifie Lot 242 ithin the Hideaway Golf Club development in the City of La Quinta, California. If -is -our understanding that the proposed residence will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were reconfigured. The most recent site grading is summarized in the referenced Report of nd -Observations-Burin h Grading prepared by Sladden Engineering along with thGempaction test results"_, ' NTA BUILD' � 7� DEPT. The referenced reports include recommendations pertaining to the construction cf residential structure foundations. Based upon our revi of "-referenced rep ts,-it 9 ur opi ion that the structural values included in the reference grading re ort repay �tiy Sudden Engineering remain applicable for the design and c nstructiorf/ t�pro s d r dent al structure DATE _ C Ill.' ' foundations. - April 10, 2013 -2- Project No. 544-13079 13-04-127 Because the Iot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building falls within the previously established building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer. We recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the sc type judged applicable to this site is St), generally de cri g ti yaVyf soil. lTlhe; fgll o Iwo ng additional coefficients and factors relevant to seismic itiafor new construction b.a the 2010 California Building Code (CBC). DUILDW- AF .! FOR ION DATE �L� —� .. April 10, 2013 -3- Project No. 544-13079 13-04-127 The seismic design category for a structure may be determined in accordance with Section 1613 of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are summarized below. Occupancy Category (Table 1604.5):11 Site Class (Table 1613.5.2): D Ss (Figure 1613.5.1):1.50g S1 (Figure 1613.5.1):0.60g Fa (Table 1613.5.3(1)):1.0 Fv (Table 1613.5.3(2)):1.5 Sms (Equation 16-36 (Fa X Ss)): 1.50g Sml (Equation 16-37 (Fv X Sil): 0.90g SDS (Equation 16-38 (2/3 X Sms}): I.00g SM (Equation 16-39 (2/3 X Smi)): 0.60g Seismic Design Category: D If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEEI Brett L. Anderso �' ERERSO ER -ON Principal Engineer No. Exp, 9/30/14 SER/gvm CIVIL ENGINEERING r?ATE TEOF CA Copies: 4/Peter Jacobs Homes CIT) BUILD DEPT. A Mi, '� CTION r?ATE _ r ISA QUINTA Please verify that soils reports contain all of the above information. In addition, to assure continuity between the investigation/reporting stage and the execution stage, please use the following checklist to verify that the conclusions and recommendations in the report cover all the required elements. Only then can we be assured that the construction documents address all of the site soil conditions. La Quinta Geotechnical Report Checklist Does the "Conclusions and Recommendations" section of the report address each of the following criteria? "Address" means: (a) the criterion is considered significant and mitigation measure(s) noted, -or; (b) the criterion is considered insignificant and explicitly so stated. Yes No Criterion ❑ Foundation criteria based upon bearing capacity of natural or compacted soil. ❑ Foundation criteria to mitigate the effects of expansive soils. ❑ Foundation criteria based upon bearing capacity. of natural or -compacted soil. ❑ Foundation criteria to mitigate the effects of liquefaction. ❑ Foundation criteria. to mitigate the effects of seismically induced differential settlement. ❑ Foundation criteria to mitigate the effects of long-term differential settlement. 7�- ❑ Foundation criteria to mitigate the effects of varying soil strength. ❑ Foundation criteria to mitigate expected total and differential settlement. Any "No" answers to the above checklist should be noted as specific required corrections. CIT f= r GTA BUIL ,- -_TY DEPT. Fl— _ .. 11 '�,JCTION n n rc BY