Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-4282 (SFD)
P.O. BOX 1504 44 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 05-00'00442.8'2 ` Property Address: 80093 VIA PESSARO APN: 772.-550-024- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 425930 Applicant: Architect.or Engineer: Lic. No.: OOR SQUARE FOOT Owner: J RIPPEE 16236 SAN DIEGNTO RD. RANCHO SANTA FE; CA 92067 . Contractor: .SOMERS CONSTRUCTION .INC, 326 ENCINITAS BLVD, STE 1 ENCINITAS, CA 920`24 (760)6,33-1324 Lic. No.: 483856 FAX (760) 777=7011 INSPECTIONS, (760) 777-7153 Date: 11/03/66 ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION _ I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: , . Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers` compensation, as provided License Class: B - - cense No.: 483856 _ for by Section 3700 of the Labor Code,'for the performance of the work for which this permit is -, issued. Date: 0 �P .Contractor: _ - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor _ Code, for the performance. of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: ' 1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 0008658-2006 .following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct,, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the -person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State 'nsation provisions of Section and agree that, if I should become sub�cirthethose License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and. Professions Code) or 700 of the Labor Code, I shall hwvisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by r any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars IS5001.: D� 3 Bio Applicant> . (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE RICERS' COMP SATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property, who builds or improves thereon, , SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the - DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN ' improvements are not intended or offered for sale. If; however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of. sale.). APPLICANT ACKNOWLEDGEMENT (_ 1 I, as owner-oftheproperty, am_exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Applicationis hereby made to -the Director of Building and Safety for a. permit subject to the • 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on.this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_) I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT .. . of La Quinta,its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. . - 2. Any. permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and'state that the above information is correct. Jatpee to comply with all city and county ordinances and state laws relating to building construction and he u rize representatives of this counts t enter upon the above-mentioned property for ' pact purp ' ✓ �� SignaturelApplicam or A� gent nt) ./ - Application Number 05-00004282 Permit . . BUILDING PERMIT Additional desc . Permit Fee 1780.50 Plan Check Fee" 1157:33 Issue Date 12/29/05 Valuation 425930 Expiration Date ., 2/25/07 Qty Unit Charge Per Extension BASE' FEE 639.50 326.00 3.5000 THOU BLDG 100,001-500,000- 1141.00 . Permit. . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 215.99 Plan Check Fee 54.00 Issue Date 12/29/05 Valuation 0 Expiration Date 2/25/07 Qty Unit Charge Per Extension BASE FEE 15.00 5007.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 175.25 537.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 10.74 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . GRADING-PERMIT. Additional desc . Permit Fee 15.00 Plan Check Fee .00 - Issue Date . . . . • 12/29/05• Valuation . . . . 0 Expiration Date .2/25/07 Qty Unit Charge. Per Extension BASE FEE 15.00 Permit MECHANICAL Additional desc . Permit Fee . . . 114.50 Plan Check-Fee 28.63 Issue Date 12/29/05 Valuation . . 0 Expiration Date 2/25/07. Qty Unit Charge .Per Extension BASE FEE 15.00 3.00 9:0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 6.00 6.5000 EA MECH VENT FAN. 39.00 1.00' 6.5000 EA MECH EXHAUST HOOD 6.50 - LQPERMIT Application Number 05-00004282 Permit PLUMBING Additional desc .. Permit`Fee 211.5.0 Plan. Check Fee 52.$8 Issue Date 12/29/05 Valuation . . 0 _ s% Expiration Date 2/25/07 Qty Unit Charge Per Extension l' BASE -FEE 15.00 23.00 6.0000 EA PLB FIXTURE. 138.00 1.00 15.0000 EA PLB BUILDING.SEWER 15:00 1.00 7.5000 EA PLB WATER HEATER/VENT 7:50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM- 9.00 12.00 .7500 EA PLB GAS PIPE >=5 9.00 1.00 15.0000 EA PLB GAS METER 15.00 - - ------------------------------ Special Notes and Comments -------- .50.07 SQ. FT. SFD THIS'PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH.CHANGE OF CONTRACTOR. ON 11-3-06•TO RICK SOMERS CONSTRUCTION. ------------------------------ ' Other Fees ART IN PUBLIC PLACES -RES 564.82 CHANGE OF CONTRACTOR 4.50 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER. -,RES 480.00 ENERGY REVIEW FEE, 115.73 DIF FIRE PROTECTION -RES •.140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.0.0 DIF PARK MAINT.FAC - RES 22.00• •DIF PARKS/REC - RES' 892.00 STRONG MOTION.(SMI) - RES 42.59. DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid Credited Due Permit Fee Total 2337,49 2337.49 .00- .00 Plan Check Total 1292.84 1292..84 .00 .00 Other Fee Total. 4423.64 4419.14 .00 4.50 Grand Total 8053.97 8049.47 .00 4.50 ' LQPERMIT - • _ .._ - - _ N Bin # City of La Quinta Building u Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and.Tracking'Sheet Permit # Project Address: go O qr Owner's Name: �- do TZPPEE A. P. Number: Legal Description: Address: to 2 N' _ p. Pa. CA City, ST, Zip: LA 4 L067 Contractor: R.Lk Telephone: 4658 — 7T11 — S3 Address: :32lc Cje_,",,T 7w JSL.aJ,, Project Description: 00c, CaoR City, ST, Zip: a e4 A, r qwvS Telephone: "7&,0— State Lic. # : is g 7S� City Lic. #: Arch., Engr., Designer: Address: City,. -ST, Zip: Telephone: State Lic. #: t Name of Contact Person: "ryL� gvaL"1' Construction Type: Occupancy: Project type (circle one): ew Add'n Alter 'Repair Demo Sq. Ft.: lr_007 #Stories: 2 # Units: Telephone # of Contact Person: o Z� Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd _ Rec'd TRACKING . PERMIT FEES. Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan.Check Balance Energy .Calcs. Plans picked up Construction Flood plain pian Plans resubmitted Mechanical Grading, plan' 2" Review, ready for correctionsfissue Electrical Sbbcontactor List Called Contact Person Plumbing Grant Deed Plans picked up H.O.A. Approval Plans resubmitted . Grading IN HOUSE:- .-"'Review, ready for corrections/issue Developer Impact Fee.. ; Planning Approval Called Contact Person A.I.P.P. ` Pub. Wks. Appr Date of permit issue School Fees .. ...Total Permit, Fees..,..... , F P.O. BOX 1504 Ini LP -A U ' 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 DEC 2 9 2005 B C TY OF LA QU NTA Application Number: 0'5-00004282 QdANCEDEPT. Property Address: 80093 VIA P APN: 772-550-024- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 425930 Applicant: Architect or Engineer: 4.4Q"_- ING & SAFETY DEPARTMENT BUILDING PERMIT Lic. No.: OOR SQUARE FOOT -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B -C8 - License N "156102 , 10 OWNER -BUILDER DECLARATION ' hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9.(commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for safe (Sec. 7044; Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. - , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: . Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/29/05 Owner: J RIPPEE 1623,6 SAN DIEGNTO RD. RANCHO SANTA FE, CA 92067 Contractor: REESE GENERAL CONTR, KEITH 80209 AVENUE 50 LA QUINTA, CA 92253 (760)564-4599 Lic. No.: 156102 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: - _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided -for by Section 3700 of the Labor Code, for the performance of_the work for which this permit is issued. - - I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1542671-2005 I certify that, in the performance of the work for which this permit is issued, Ishall not employ any person in any manner so as to become subject to. the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of.Section 3700 of the labor Code, I shall forth,*tply wfth 1pose pro�i5tgns.- ANARNING: FAILURE TO SECURE`WORKERS' COMPENSATION COVERAGE -IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and,Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any actor omission related to the work being performed under or following issuance of this permit. , 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby author re resentatives of this county to enter upon the above-mentioned property for inspeGoon pur jRes. �% Application Number 05-00004282 -Permit BUILDING PERMIT Additional desc . Permit Fee . . 1780.50 Plan Check Fee 1157.33 Issue Date Valuation 425930 Expiration Date 6/27/06 Qty Unit Charge Per Extension BASE FEE 639.50 326.00 3.5000 -----------------------------------------------------,- THOU. BLDG 100,001-500,000 .---------------- 1141.00 ------ -Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 215.99 Plan Check Fee 54.00 Issue Date . . . . Valuation . . . 0 Expiration Date 6/27/06 Qty Unit Charge. Per Extension BASE FEE 15.00 5007.00 .0350 ELEC NEW RES - 1 OR-2 FAMILY 175.25 537.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 10.74 . 1.00 15.00.00 ----------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15:00 Permit . . . GRADING'.PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/27/06 Qty Unit-Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit MECHANICAL Additional desc . Permit Fee . . . 114.50 Plan Check Fee 28.63 Issue Date Valuation 0 Expiration Date .6/27/06 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K, 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 6.00 6.5000 EA MECH VENT FAN 39.00 1:00 6.5000 --------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50. LQPERMIT - Application Number 05-00004282 Permit PLUMBING Additional desc Permit Fee . . . . 211.50. Plan Check Fee 52.88 Issue Date Valuation 0 Expiration Date 6/27/06 1 Qty Unit Charge Per Extension BASE FEE 15.00 23.00 6.0000 EA PLB FIXTURE 138.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 - 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM_ 9.00 12.00 .7500 EA PLB GAS PIPE >=5' 9.00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 5007 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL &.SPA BLOCK WALLS OR DRIVEWAY APPROACH.December 29, 2005 7:01:56 AM jjohnson Other Fees . . . . . ART IN PUBLIC PLACES-RES 564.82 DIF.COMMUNITY CENTERS-RES '74.00 DIF CIVIC CENTER "- RES 480.00 ENERGY REVIEW FEE 115.73 DIF FIRE PROTECTION-RES 140.00 GRADING PLAN.CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 42.59 DIF STREET MAINT FAC-RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid Credited Due Permit Fee Total 2337.49 .00 00 2337.49' Plan Check Total 12.92.84 500.00 .00 792.84 Other Fee Total 4419.14 .00 1.00 4419.14 Grand Total 8049.47 500.00 .00 .7549.47 K E I T H R E E S E l GENERAL CONTRACTOR 80209 AVENUE 50 LA OUINTA, CALIFORNIA 92253 , 760-564-4599 ' 760-564-5111 Fax ; # November 2, 2006 City, of La, Quinta 78-495 Calle Tampico La Quinta, Ca 92247 Re: Rippee Job at Lot 210, The Hideaway, 40-093Via Pessaro:I' Dear Sirs: On September 1, 2006 our company Keith Reese- General Contractors, the contractor of record for the above mentioned job, was fired by the owner Jeffry Rippee. As of the date of this letter, we have not'received any correspondence from Mr. Rippee, ` r formally or in writing terminating our contract. ` Mr: Rippee_ is currently doing work at the job with a contractor from out of the area.. They have not formally removedus from the job, in your office nor at the Lending Bank. Since as of this date I am:still formally the Contractor of Record, I wish to either be removed by your office or to shut the job down. I do not *wish to accept the liability,or responsibility for any work performed after September 1, 2006. _ Please advise what steps you intend to do to remove our company from this job. Yours truly, Keith Reese, General Contractor Coachella Nalle Unified School District y This Box For District Use Only 83-733 Avenue 55 Thermal, CA. 92274 DEVELOPERYEES PAID ' (760) 398-5909.- Fax (760) 3981224 AREA:.AMOUNT LEVEL ONE AMOUNT:' LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/WD. AMOUNT: i DATE: - RECEIPT; CHECK #: - INITIALS: CERTIFICATE OF COMPLIANCE !(California Education Code 17620) Project.Name: Jeffrey G. Rippee/ Residence @Hideaway Date:: December 22, 2005 Owner's Name:. Jeffrey G. Rippee/ Pacific View Estates Phone No,. (760) 250-9782 Project Address:.. 80093 Via Pessaro, La.Quinta, CA Project Description:..' . 1 Sirigle.Family Dwelling APN: 772=550-024 Tract #i Lot #'s: p2 / Type of Development: Residential !XX'. " . Commercial Industriah . Total Sqnare Feet of Building Area: 5,007 sq. Ft.. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: • 12/22/0.5 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE E SATISFIED IN . ACCORDANCE WITH ONE OF.THE FOLLOWING:.(CIRCLE ONE) Education Code Gov: Code Project Agreement Existing Not Subject to Fee 17620.. 65995 Approval Prior to•1/1/87 .Requirement Number of-Sq.Ft: 5,007 Amount per Sq.Ft. $ 2'808.' Amount Collected $. 14,420.16 a - Building Permit Application Completed:.Yes/No By: Carey M. Carlson, Asst. Supt.; Business. Services., Certificate issued by: Leticia C.Torres; Facilities Clerk Signatur NOTICE OF 90 DAYPERIOD FOR PROTEST OF FEES AND STAiE OF FEES Section 66020 of the Government Code asserted by Assembly. Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in. accordance with section 66020 of the Government code and other applicable law; this Notice shall serve to advise you that •the 90 -day protest period in regard to such Fees or the validity thereof, commences with the. payment of the fees'or.:performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein sefforth, whether payable at this time or in whole or, in part prior to' issuance of a Certificate of Occupancy. As in the latter, the 90 days starts: on the date hereof. This Certificate of Compliance is valid for thirty, (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been' issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. vlV:c/mydocs/dcvlees/certi'ticate ofcompliance form tablesTO USE.doc m6/033 I . r .Oct 17 05 02:39p Jeff Rippee 858-759-5358 p.1 RECORDING REQUES I BY:. SO"jrHLAND TTTLE COMPANY • »OC M 2®04--®514984 ,, AND WFIEN RECORDED, MAIL M. Paget/2084 tss t c Ti1i Foo : aid " Page ! of 3 Ooe T Tax Paid 'Recorded in Official Records County of Riverside Gary L. Orao, icf6ty G. Rippee Assessor, -County Clerk a Recorder S�.Di g,C 27 1 filIIllllllll1AII�II�IINN -T-RA ce4p _,to nn MMMMUMMM WREMMMMMM 'see:==mMMee r3 GRANT DEED;----�` ASSESSOR'S PARCEL NO.: 772-550-024A Tiie undersigned Cn mtor(s) declare that the DOCUMENT TRANSFER TAX IS: I AIH TTILE ORDER NO.: 64601553 S 825.00 County _ ESCROW NO.: 23487-003 XX computed on the full value of the interest of property conveyed, or'-,:`• « computed on the full value less the value of liens or encumbrances remaining thereon ' at the time of sale: _ OR traosfer is EXEMPT fiom tax for the following reason: FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Landon D. Mack, aSingle Man,, hereby GRANT(S) to Jeffrey G.`Rippee , a single than - all that real property situated in the City of , County of Riverside, State of , described as: Lot 210 of xAmended Tract 29894-2as per map recorded in Book 327 on Page(s) 56 to 88 inclusive of Maps as recorded in office of the County Recorder of said County. see exhibit A attached for complete legal description +" "•' Dated May 16, 2004 ; State of California } r l ` Countyof Riverside } a r On 5/27/2004 , Before me Ruth A. Furst Notary Public D. M , Personally ahmrcd f -Landon D. Mack Personally lmown 10 me (or provided to me an the basis of satisfactory RM A FURST evidence) to be the person(s) whose name(s) islari subscribed to the . t;; mm;aston t11366s30 +" within insbument and acknowledged to me that he/she! executed the !� - ' - ^ �' ledg tlsey y .,� - Caiirom.a .i: • some in hislher/their authorizedcapac ). and that by his/her/their. Rroi.-zi;;s (ourrty signatures) on the ' e s) or the entity upon beheti of _ which the petson(s) the. ent - - - RU Hik FURST offi Sed Commission 01366930 NOtary Pu0!ic- Calfomis Riverside County s. Signature 1AyComm Expifga,hf 27, 2= , (This area for official notary Seal) MAIL TAX STATEMENTS TO: Jeffrey G. Rippoc 8168 Santaluz Village Green N sr, San Diego, CA. 92127 e � it .' • ; Oct 17'05 02:39p Jeff Rippee, 858-759-5358 p-2 ilTLE EO' NCEM FLUS!!! REFERENCE FILE NUMBER 145 S. GLENOAKS, BLVD., #466 03-3774-18-ESC -Ep , BURBANK, CA 111502 .,(81 s) 771-7676 (message center) Please write above number on check ,. IMPORTANT NOTICE• This.company has no affiliation with any federal, state or focal entity. Visit us on the web: www.ti0econcepts.com E-mail us with your questions: titleconceptsOcs.com DECLARATION OF HOMESTEAD REQUEST FORM: Please fib in this form completely. Returrrthils form and a check or money,order for $40.00 made payable toTITLE CONCEPTS PLUS in the return envelopej provided for your convenience. Your DECLARATION OF HOMESTEAD will be sent to you within+25 working days. Please type or print. Property Address- Mailing Address ' Property is located in the county of Zip Code Homeowner's Name' . Last, First Middle Spouse's Name Last First Middle Are you or your spouse 65 or. older?. O Yes O No Are you or spouse mentally :or physically disabled? " 0 Yes , ❑ No Type of property: O House O Condominium O Apartment O Other f t Please indicate how you wish to file (please check one). ® Husband and, wife as joint owners. ` O Separate property of husband. 'U Separate property of wife: O Unmarried, with dependents O Yes O No dependents Your (homeowner real estate document package) and your Declaration of Homestead will be sent to you in about 25 working days.Your package will include your blank ready to use Grant Deed, and Quitclaim Deed, and your fully prepared Declaration of Homestead. If more than one person "other than husband and wife as joint owners" is filing to homestead the same property, an additional $20.00 is due for each separate owner.You may file to Homestead your interest in said property without your co-owners. Title Concepts Plus will prepare your declaration based on the information supplied by you. For faster service return this forrri and the enclosed copy of Grant Deed., t YOU HAVE A LEGAL RIGHTTO PROTECT THE EQUITY IN YOUR HOME. Copy"11102= by TnTLE CONCEPTS P W s TCP62 z TITLE 24 REPORT } Title 24 Report for: r Lot 210 Hideaway- Tract #29894=2ED LA La Quinta, CA 9225APP Project Designer: Y Villa & Associates 1340 West Valley Parkway..-Suite-207, Escondido, CA 92029 -(760) 735-8874 r - Report Prepared By:, r - _ -'Wayne Seward; CEA R01-04-27,3' Bear Technologys 7774 Calle Mejor Carlsbad, CA 92009 (760) 635-2327 r _ Job Number: r 5091511 Y SEP 2 Date: a 1 2005 .9/17/2005 ` . The EnergyPro computer program has been used to perform the"calculations summarized In this compliance, report This program has approval and Is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Effidency Standards.. This, program developed by Energy§ LLC - www.energysofLcom. 1 EnergyPm 4.0 by Energysott Job Number. 5091511 User Number.. 5956. I r EnergyPro 4.0 by EnergySoft Job Number. 5091511. User Number: 5958. Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R Lot 210 Hideaway_ 9/17/2005 Project Title Date Tract # 29894-2 1 a Quinta Project Address SulMing Pennk d Bear Tp .hnnlnays (760) 635-2327 Documentation Autho ' Telephone Plan ChecklDate Source Energy Use Standard Proposed Compliance (kBtu/sf--yr) Design Design Margin Space Heating 1.84 1.17 0.66 Space Cooling 52.33 51.26 1.08 Fans 7:86 7.78 0.08 Domestic Hot Water 4.83 4.17 0.66 Pumps 0.00 0.11 -0.11- Totals 66.85 64.49 2.37 Percent better than Standard: 3.5% Building Type: (0 Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addltion ❑ Existing + Add/Aft (North) 0 deg Natural Gas Area: 823 ft2. Avg. U: Ratio: 16.4% Avg. SHGC: BUILDING ZONE INFORMATION Zone Name" Floor Area HVAC: 5 007 OPAQUE SURFACES Insulation Act. 0.40 0.35 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: 5,007 ft2 n/a ft2 86 ft2 4,316 ft2 9.7 ft 1.00 2 # of Thermostat Vent Volume Units Zone Type Type Hgt. Area 4A 1_00 cmdl inrwd Setback _ _� AIA Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wood 2 8277 _n 02R R_38 R_0.0 _a_22 Root_ Wood 798 0.036 R_30 R-0.0 0 22 Wall Wood 376 0.074 R.19 R-0.0 _0 90 FOOL_ None 60 1-450 Nme R -A n 0 90 Wall Wood 736 0.074 R_19 RR -0.0 90 90 Wall Wood 261 0.074 R_19 11-0.0 180 90 Wall Wood 711 0.074 R_19 R.0.0 270 An Wall Wood 3S5 0.074 R.19 R -n A _0 90 Bopp_ Wood 691 0.026 R_38 R-0.0 _Q 0 wall _ Wood 291 0.074 R_19 R-0.0 _0 go Wall Wood 297 0.074 R_19 R -n 0 _90 An Wall Wood 22a 0.074 R-19 R-0 0 180 90 Wall Wood 294 0.074 R_19 RAO 270 _ 90 Fbor Wood 76 0.048 R-19 R-0.0 _�80 Floor Wood 10 0.048 R.19 R-0.0 _0 180 Gains Condition Y / N Status JA IV Reference Location / Comments WAS 1 st Flonr Zone 02-A9 1 at Floor Zone 091AS 1st Floor Zone 28-A1 1 st Floor Zone D9 A5 1st Floor Zone 09-A5 1st Floor Zone 09-A5 Iat Floor Zone 09-A5 1 st Floor Zone 01-A8 2nd Floor Zone Mm 2nd Floor Zone D9 -AS 2nd Floor Zone 09-A5 2nd Roar Zone 09-85 2nd Floor Zone 21-A4 Znd_Roor Zone 21-A4 2ad_Floor Zone EnergyPro 4.0 by EnergySoft User Number: 5958 Job Number. 5091511 p ege:3 of 12 Certificate Of Compliance: Residential (Part 2 of 3) CFA R Lot 210 Hideaway Bug 9/17/2005 Pr*et Title Screen Date Screen FENESTRATION SURFACES Screen Bug Screen Bug True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments L Window Front (N ) 24.0 0.400 NFRC -= NFRG 0_ _O& New Double NonMN LowF 1st Floor Zone 2 Window Left (East) 25.0 0.400 NFRC 0_35 NFRC 90 90 New Double NonMU LawE 1st Floor Zone 3 Window Left (East) 9.0 0.400 NFRC 0_35 NFRC 90 90 New Double NonMU LowE 1st Floor Zone 4 Window Left (East) 30.0 0.400 NFRC 0_35 NFRC 90 90 New Double WWII! LowE 1st Floor Zone 5 Window Left (East) 10.0 0.400 NFRC 0_35 NFRC 90 90 New Double NonMU LowE 1 st Floor Zone 6 Window Left (East) 10.0 0.400 NFRC 0.35 NFRC 90 _900 New Double NonMU LowE 1 st Floor Zone 4 Window Rear (South) 3.0 0.400 NFRC 0.35 NFRC 180 90 New Double NonMU LowE 1 st Floor Zone 8 Window Rear (South) 3.0 0.400 NFRC 0_35 NFRC 180 90 New Double NonMU LowE 1st Floor Zone 6 Window Rear (South) 3.0 0.400 NERC_ Q NFRQ _1$0_ 90 New _Double NonMU LowE 1 st Floor Zone 1Q Window Rear (South) 3.0 0.400 NFRC NFRC _LQ 90 New Double NonMU LmE 1st Floor Zone " Window Rear (South) 3.0 0.400 NFRC X35 NFRC 180 90 ye -Double WWII] LowE 1 st Floor Zone 12 Window Rear (South) 48.0 0.400 NFRC 0_35 NFRC 180 90 New Double NonMU LowE 1st Floor Zone 1,'1 Window Rear (South) 48.0 0.400 NFRC 0"35 NFRC 180 _,90_ New Double NonMtl LowE 1 st Floor Zone 14 Window Rear (South) 180.0 0.400 NFRC 0_35 NFRC 180 90 New Double NonMU LowE 1st Floor Zone 15 Window Rear (South) 128.0 0.400 NFRC 0_35 NFRC 180 90 New Double NonMU LowE 1 st Floor Zone 16 Window Right (West) 10.0 0.400 NFRC 0_35 NFRC 270 90 New Double NonMU LOWE 1st Floor Zone 17 Window Right (West) 4.0 0.400 NFRC 0_35 NFRC 270 90 New Double Norft LowE 1st Floor Zone 18 Window Right (West) 10.0 0.400 NFRC 0_35 NFRC 270 90 New Double NonMU LowE 1st Floor Zone 19 Window Right (West) 4.0 0.400 NFRC 0.35 NFRE 270 9 New Double NonMU LowE 1st Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt Wd. Len. Hgt. LEA. REA. Dist. Len. Hgt. Dist. Len. Hgt. 2 3 4 5 6 7 8 9 To- Ti - 12 01112 13 14 15 16 17 18 19 Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick.Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 271 None No Insulation 26 -Al New 1st Floor Zone r Run InIdatlon Time: 09/1710507:51:12 Run Code: 112896887_2_ I EnergyPro 4.0 by EnergySoft User Number. 5956 Job Number. 5091511 Page:4 of 12 Certificate Of Compliance: Residential (Part 2 of 3) CFA R Lot 210 Hideaway Project Title pate 9/17/2005 FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC� Azm. Tilt Stat. Glazing Type Location/ Comments 2Q 21 Window R4ght Window Right est) 10.0 0.400 NFRC 0.35 NFRC 270 --K New Double NonMtl LowE (West) 30.0 0.400 NFRC 0_35 NFRC 270 90 New Double NonMtl LowE 1st Floor Zone 1st Floor Zone 22 Window Right (West) 10.0 0.400 NFRC 0_35 NFRC 270 90 New Double NonMU LowE 1 st Floor Zone 23 Window Right (West) 36.0 0.400 NFRC 0_35 NFRC 270 90 New Double NonMU LOWE 1st Floor Zone 24 Window Right (West) 10.0 0.400 NFRC 0_35 NFRC 270 90 New Double NonMU LowE 1st Floor Zone 25 Window Front (North) 6.0 0.400 NFRC 0.35 NFRC 0 90New Double NonMU LowE 2nd Floor Zone 26 Wmdow Front (North) 6.0 0.400 NFRC Q35 NFRC = 90 New Double NonMU LowE 2nd Floor Zone 27 Window Front (North) 3.0 0.400 NFRC 0.35 NFRC 0 90 New Double NonMU LowE 2nd Floor Zone 2$ Window Front (North) 3.0 0.400 NFRC 0.35 NFRC 0 -90 New Double NonMU LowE 2nd Floor Zone 2`Z Window Front (North) 4.0 0_400 NFRC 935 NFRC 0 90 New Double NonMU LowE 2nd Floor Zone 3Q Window Front (North) 4.0 0.400 NFRC 0,35 NFRC 0 90 New Double NonMU LowE 2nd Floor Zone 31 Window Left (East) 27.0 0.400 NFRC 0_35 NFRC 90 90 New Double NonMU LowE 2nd Floor Zone _ 33 Window Left Window Left (East) ---2,Q 0.400 NFRC 0.35 NFRC _90_ & New Double NonMU LowE (East 22.4 0.400 NFRC 0_35 NFRC 90 90 New Double NonMU LowE 2nd Floor Zone 2nd Floor Zone 34 Window Left (East) 16.0 0.400 NFRC 0_35 NFRC 90 90 New Double NonMO LowE 2nd Floor Zone 3355 Window Left (East) 22.4 0.400 NFRC 0_35 NFRC 90 90 New Double NonMU LowE 2nd Floor Zone 36 Window Left (East) 22.4 0.400 NFRC0_35 NFRC 90 90 New Double NonMtl LowE 2nd Floor Zone 37 Window Rear (South) 4.0 0.400 NFRC 0_35 NFRC 180 90 New Double NonMU LowE 2nd Floor Zone 38 Window Rear (South) 4.0 0.400 NFRC 0.35 NFRC 180�9 New Double NonMU LowE 2nd Floor tone 1. Aicate source elther from NFRC or Table 116A. 2. Indleate source elther from NFRC or Table 1188. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Right Fin Hgt. Dist. Len. Hgt. 20 Run Srmen 0 7R 21 22 23 24 25 26 27 28 29 5 31 32 33 34 35 36 37 38 Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Locationt Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition LocatioN Type Length R -Val. Location. JA IV Reference. Status Comments Run Initiation Time: 091705 07:51:2 Run Code: 112696SV2 EnergyPro 4.0 by EnergySoft User Number. 5956 Job Number 5091511 Page:5 of 12 Certificate Of Compliance: Residential (Part 2 of 3) CF -IR Lot 210 Hideaway 9/17/2005 Project Tale We FENESTRATION SURFACES # Type Area LI -Factor" SHGCZ True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments $,Q 40 Window Rear window Right (South)_ 16.0 (West) 2.0 0.400 NFRC -= .NFRC 180 __Q New Ombie NoWfl-LowE 0.400 NFRC 0_35 NFRC 270 90 New Double NanMO LowE 2nd Fkxw Zone 2nd Floor Zone 41 Window Right (West) 2.0 0.400 NFRC 0_35 NFRC 270 90 New Double NonMti LowE 2nd Floor Zone' 42 Window Right (West) 6.0 0.400 NFRC0_35 NFRC 270 90 New Double NonMtt LowE 2nd Floor Zone 1. Indicate source either from NFRC or Table 116k 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING # Pytnrinr C<1ftAn Turn Cut% -f` 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Len. Left Fin Right Fin Dist Len. Hgt Dist Len. Hat. Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 09117/05 07.51.12 Run Code: 1126968672 EnergyPro 4.0 by EnergySoft User Number. 5956 Job Number: 5091511 Page:6 of 12 Certificate Of Compliance: Residential (Part 3 of 3) CF -JR Lot 210 Hideaway 9/17/2005 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback t HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Ratedl Tank • Energy Standbyl Tank Insul. Water Heater # in Input -Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Generic 75 gal Large Gas RecrcMme+Temp 1 77,500 0 New 0.75 0.00% 0.0 Multi -Family Central Water Heating Details Hot Water'Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation I For small gas storage (ratedinput <= 75000 Btulhr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Attached Heating & Cooling load summary is submitted as part of the calculations required by the current regulations. DO NOT USE FOR ACTUAL HEATING & AC DESIGN COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to Implement them. This certificate has been signed by the Individual with overall design responsibility. The undersigned recognizes that compliance using dud design, dud sealing, verification of refrigerant charge and TXVs. Insulation installation quality, and building envelope sealing require Installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Villa & Associates Address: 1340 West Valley Parkway, Suite 20T Escondido, CA 92029 Telephone: (760) 7358874 LIC. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Teleohone: Documentation Author Name: Wavne Seward. CEA R01-04-273 Title/Firm: Bear Technologys Address: 7774 Calle Me}or Carlsbad, CA 92009 ' Telephone: (760) 635.2327 09/17/2005 (signature) (date). Certificate Of Compliance: Residential (Addendum) CFAR Lot 210 Hideaway 9/17/2005 Project Title Date Special .Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified In this checklist. These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the aosquacy.oT me speaai lustmcatron ana aocumentatron submrttea. Plan Field The Roof "R-38 Roof(R.38.200.16) includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. An Air Retarding Wrap must be installed per the manufacturers specifications that must comply with ASTM E1677-95. HERS Required Verification Items in this section require field testing andlor verification by a certified home energy, rater under the supervision of -a CEC- approved HERS pprovider using CEC approved testing and/or vartficatlon methods and mumpe reported on the -CF -4R Installation certificate: .. pin Field The HVAC System "HVAC" incorporates HERS verified Duct Leakage. Target leakage Is calculated and documented on the CF -4R. The HVAC System "HVAC incorporates'a HERS:verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. r t E-rgyPro 4.0 by EnergySoft User Number. 599 Job Number: 5091514 Page:8 of 12 . i ' Mandatory Measures, Summary:. Residential (Page 1of;2) MF.-1Ri , NOTE: Low-rise, residential bulldings subject to the Standards must contain these measures regardless of the compliance approach used More stringmk compllence requirements from the Certificate of Comp) mm superoedes the Items marked with and asterisk 0 below. When this cl addid Is Incorporated Into the permit - documents, the features noted shad be considered by all parties as minimum oanponent.pertomanoe spedflcatlons for the mandatory measures whether they are shown elsewhere In the documents or on this checklist only. I DESCRIPTION. Instmcdons. Check or initlal applicable boxes when completed or check -N/A U not WA NIA DESIGNER ENFORCE - HENT Building Envelope Measures § 1500): Minimum R-19 In wood calling Insulation or equivalent U -factor In metalframe ceiling. ❑ ❑X ❑ § 150(b): Loose fill Insulation manufacturer's labeled R -Value: ❑ ❑ , § 150(c): Minimum R-13 wall insulation Inwood framed walls 'orequlvalern U4actor in metal frame walls, (does not ❑ 0, ❑ appy to exterior mass walls). ❑ ❑X § 150(d): Minimum R-13 raised floor insulation in framed floors or. equivalent U -factor. ❑X ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs Q ❑ ❑ 1. Masonry and factory -built fireplaces have: a: closable metal or glass door covering the entre opening of the firebox ❑ Q ❑ b. outside air Intake with damper and control, flue damper and control ❑ Q ❑ 2. No continuous burning gas pilot lights allowed ❑ ❑X ❑ § 150(f): Air retarding wrap Installed to comply with. 6151 meets requirements specified In the ACM Residential Manual.. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. Q ❑ ❑ § 150(1): Slab edge Insulation - water absorption rate for the Insulation alone without faclngs no greater than 0.3%, water vapor ❑X ❑ ❑ penmeance rate no greater than 2.0 permlinch' , Page:9 of 12 § 118:. Insulation specified or installed meets Insulation Installation quality standards. ,Indicate type and include 0 ❑ ❑ CF -611 Form: , § 116-17: Fenestration Products, Exterior Doors, and IrgiltratbNEnd Itraton Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to Amit air leakage. ❑X ❑ ❑ 2. Fenestration products (except field fabricated) have label with ceNfiedtlFactor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ 0 ❑ 3. Exterior doors and windows weatherstrlpped; all joints and penetrates caulked and sealed. ❑X ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ .. ❑X ❑ § 150(h): Heating and/or cooling loads calculated In accordance with ASHRAE, SMACNA or ACCA ❑ ❑X ❑. § 1500): Setback thermostat on all applicxible heating and/or cooling systems Q a ❑ , § 1500): Water system pipe and tank Insulation and cooling systems line Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an Installed thermal resistance of R-12 or greater. 2. Bade -um tanks for soler systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑X ❑ ❑ Insu lellon or R-16 Internal insulation and Indicated on the exterior of the tank showing the R -value. 3. The following piping Is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest tic water heater tank, non-reclrculating systems, and entire ❑ ❑X length of recirculating sections of hot water pipes shall be Insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and Q ❑ ❑ Indirect hot water tank shall be Insulated to Table 150-8 and Equation 150-A 4. Steam hydropic heating systems or hot water systems > 15 psi, meet requirements of Table 1234L ❑X ❑ ❑ 5. Insulation must be protected from damage, Including that due to sunlight, moisture, equipment maintenance, ❑X ❑ ❑ and wind: 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or Is enclosed Q ❑ ❑ entirely In conditioned space. 7. Solar water -heating systems/collecicns,are certified by the Solar Rating and Certification Corporation, i ❑X ❑ ❑ EnergyPro 4.0 by EnergySoft -- User Number. 5956 Job Number. 5091511 , Page:9 of 12 0 Mandatory Measures Summary: Residential (Page 2 of 2) WAR NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Morestringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere to the documents or on this checklist only. Instructions: Check or InIdal applicable boxes when completed or check N/A if not DESCRIPTIONepplicable. ENFORCE- WA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. Ali ducts and plenums installed, sealed and Insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 65; supply -air and retumair duds and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 161A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ © ❑ sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air: Building cavities and support platforms may contain duds. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber. adhesive ❑ ® ❑ dud tapes unless such tape is used in combination with mastic and draw bands.. ' ® ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ® ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, Including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shag be protected as above or painted with a coating that Is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible duds cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑X ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot fight 2. System is installed with: a. At least 36' of pipe between filter and heater for future solar heating. - ® ❑ ❑ b. Cover for outdoor pools or outdoor spas. X❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑X ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot fight. (Exception: Non -electrical cooking appliances with plot < 150 Btulhr) § 118 (t): Cool Roof material meets specified criteria. Q ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150•C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES -.OUTDOOR HID: contain only high efficacy lamps as outlined in.Table 150-0, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently Installed luminaires in kitchens shag be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ © ❑ in Section 130(c), of permanently Installed luminaires In kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry- rooms, utility rooms shag be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Sedan 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms be high efficacy luminaires less than 70 ft) OR bya dimmer OR ❑ X❑ ❑ shall (except closets are controlled switch are controlled by an occupant sensor that complies with Section f 19(d) that does'not turn on automatically or have an . always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as ab tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting andrnanently mounted to a residential building or to other buildings on the (nnot © El,' Elsame lot shall be high efficacy luminaires including fighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shag have lighting that complies with Sections 130,132, and 147. ❑❑ Lighting for parking garages for 8 or more vehicles shall have fighting that complies with Section 130,131, and 146. § 150(k)8: Permanently installed fighting in the enclosed, non-dwel ing spaces of low-rise residential buildings with four or more © ❑ ❑ dwelling units shag be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro4.0 by EnergySoft User Number. 5956 Job Number: 5091511 Page:10 of 12 J EnergyPro 4.0 by Energy8oft User Number. 5958 Job Number. 5091511 Page:1.1 of 12• Residential Kitchen Lighting Worksheet �-WS=5R''`'n Lot 210 Hideaway 9/17/2005 ' .r Project This Date At least 50% of the total rated wattage of permanently Installed luminaires In kitchensmart be In luminaires that are high efficacy luminaires ' as defined In Table 150.0. Luminaires that are not high efficacy must be switched separately: . Kitchen Lighting Schedule. ' Provide the following Information for all luminaires to be.instailed in kitchens. , High Efficacy Luminaire Type High Efficacy?.. Watts :Quantity;, Watts Other Watts (1) 10w Compact Fluorescent 2D Elec 'Yes X No 13.0 .x J ` 6 = 78 - or (1) 7w Compact Fluorescent Twin 4 Pin Elec Yes X1 No 11 8.0 .X 95 = 760 or (1) 9w Compact Fluorescent Twin 4 Pin Elec Yes X1' No 10.0 x 20' = 200 or fluorest T8 Elec (2) 3 Rcen Yes' X No f 48.0 X 4 . = 192 or 75w Surface Mount Incandescent Yes I No I X 75.0 ' x 14 = or1.050 50w Low Voltage Halogen. Yes No X54.0 x 6 , _ r (1) 13w Compact Fluorescent Twin 4 Pin Elec Yes 5F No ITOx 7 = 119 or (1) 14w Linear Fluorescent T5 Elec Yes X No. 18.0 x 5 = 90 or .Yes No x = .. or Yes No x = or Yes No x = or Yes ' No x _. or Yes --'No x = or Yes No x = or Yes No x _ or Yes No x _ or Yes No x _ or Yes No _ xor Yes No x or Yes No x = or " Total A: 1.439 B: 1.374 COMPLIES IF A z B r YES El NO ❑ J EnergyPro 4.0 by Energy8oft User Number. 5958 Job Number. 5091511 Page:1.1 of 12• +. s _ , w.:.wnaixnt.:�f�•ce:.way..xe..:i....u,«..o+:cwrx....-...a+�a._aE.:<.r..wM..i .-sr.. : TY.a7�'.�9.... "��P!"+�R"voF�x^-y�"�' — ___ HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY:4;dK PROJECT NAME DATE Lot 210 Hideaway 9/17/2005. SYSTEM NAME FLOOR AREA HVAC 5,007 NGINEERING CHECKS ISYSTEM LOAD Number of Systems'___ 3 Heating System Output per System 80,000 Total Output (Stuh) 240,000 Output (stuh/sgR) 47.9 Cooling System Output per System 60,000 Total Output (Btuh) 180,000 Total Output (Tons) 15.0 Total Output (Stuhlsgft) 35.9 Total Output (sgft/ron) 333.8 Atir System CFM per System 2,000 Airflow (cfm) 6,000 Airflow (cfm/sgft) 1.20 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 outside Air (cfm/sgft) 0.00 Note: values above aiven at ARI conditions 0.0 of 0 OutskJe Air 0 dm 69.3 OF 78.5/49.1°F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I gensiblel Latent CFM I Sensible 50,W41 1 79 522 ice (80.0/14.0) 221,606 0 240,000 Total Adjusted System Output221 606 0 240000 (Adjusted for Peak Deslgn CondItions) TIME OF SYSTEM PEAK F Aug 2pml Jan 12 am 69.3 OF 69.30F 105.OoF Supply Fan Heating Coil 6000 dm h Return Air Ducts i 78.5 / 49.1 OF 78.5/49.10F 55.0 / 37.5 of '' Supply Fan Cooling Coil 6000 cfm 4.0 by EnergySoft User Number. 5956 Return Air Ducts ' Job Number: 5091511 Supply Air Ducts 104.3 of ROOMS 70.0 of Supply Air Ducts 55.5/37.8OF 4.2% R.H. ROOMS 78.0 / 48.9 OF 2 of -12