Loading...
11-0192 (SFD)P.O. BOX 1504 ^' VOICE (760) 777-7012 78495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA, 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 5/13/11 Application Number: 11-00_0.0.0.192 - Owner. Property Address: 80429 VIA PESSARO KANTER BRUCE & MARLENE t� APN: 772-520-056- - - 53664 VIA BELLAGIO Application description: DWELLING SINGLE FAMILY DETACHED' LA _QUINTA, CA 92253 O Property. Zoning: LOW DENSITY RESIDENTIAL Application valuation:. 559749 yp�� t \a1 Contractor: �tyiN� 11 Applicant: Architect or Engineer. FEDDERLY & ASSOCIATES Cfj(Y of j�Ggx• �.• } Q > Z4 ASG *MRfouort., 38747 NOPALES ROAD , T1I1-►•?°1 PALM DESERT, CA 92211 �.&07& (760) 773-5205 Lic. No.: 818923 LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATIONDECLARATION- I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty ofperjury one of the following declarations: Section 7000) of Division, of the Business an rofes � als Co�� , ancym License is in full force and effect. I have and will maintain a -certificate of consent to self -insure for.workers' compensation, as provided - • ,;license Class: B - Li t(s -N /1 18923 - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is V/ issued. Date: �� % ontractor: I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor _ Code, for the performance'of the work for which this permit Is Issued. My workers' compensation OWNER-' LD DECLARATION - - insurance. carrier and policy number are: - • t hereby affirmunder penalty of perjury that I am exempt I the Contractor's State License Law for the' Carrier EVER INS - Policy Number .760000440081 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of the workfor which this permit is issued, I shall not employ any • construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the _ - , person in any manner so as to bebom�,sutbject to "e wor er ' compensation laws of California,, permit to file! signed statement that he or is licensed pursuant to the provisions of the Contractor's State - ..and agree that, if I shoutecomcot orker c pensation provisions of Section license Law(Chapter 9 (commencing with Section 7000)of Division 3 of the Business and Professions.Code) or00o700 of a Labor Code, hall th ply 'i o provisions. - that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by -WO./� / P any applicant for a permit subjects the applicant to a civil penalty of not m6re than five hundred dollars ($500).: - - Dat ���/// pplicant: ( 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - - • the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The - WARNING: FAILURE TO SECURE WORKERS' COMPENSATI VERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND C FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the - .DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within • • SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - - one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).' - - APPLICANT ACKNOWLEDGEMENT ( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Seca . IMPORTANT Application is hereby made to the Director of Building and Safety. for a permit subject to the - - 7044,. Business and Professions Code:. The Contractors' State License Law does not apply to an owner of :condition's and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). - whose benefit work is performed under or pursuant to any permit issued as a result of this application, . (_ 1 I am exempt under Sec. , B.&P.C. for this reason . the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work .being performed under or following issuance of this permit. Date: Owner: - - 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject . CONSTRUCTION LENDING AGENCY - permit to cancellation. - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above infoin! ' is Zeb i agr to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to buildin str' n, nd_uth representativesof this connto nter upon the above-mentioned propert or sp urp - Lender's Name:- - Datenature(Applicant or Agent): Lender's Address: LQPERMIT - LQPERMIT Application Number _ 11-00000192 Structure Information Construction Type . . . . TYPE V, UNPROTECTED Occupancy Type . . . . .. DWELLG/LODGING/LONG <=10 Other struct info . . . . CODE EDITION 2010 # BEDROOMS 4.00 FIRE SPRINKLERS. YES GARAGE SQ FTG 1040.00 PATIO SQ FTG 1085.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 6317.00 Permit BUILDING PERMIT Additional desc Permit Fee . . . . 2219.50 Plan Check•Fee_ 1442.68 Issue Date Valuation 559749 Expiration Date _.. 11/09/11 . Qty Unit Charge Per Extension BASE FEE 2039.50 60.00 3:0000 THOU, BLDG 500,001-1,000,000180.00 --------------------.---------- --------------- - ------ -- -- -------_- ` Permit ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 293.60 Plan Check Fee,.- 73.40 ;. Issue Date . . Valuation 0 Expiration Date 11/09/11 ,. Qty -'Unit Charge Per Extension BASE FEE - 15.00 6317.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 221.10 _ 2125.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL' 42.50 1.00 15.0000 +. --------------------------- EA ELEC TEMPORARY POWER POLE --------------------------------------- 15.00 ----------- Permit GRADING PERMIT Additional desc-. Permit Fee 15.00 Plan. Check Fee .00. Issue Date Valuation . . 0 ' Expiration Date 11/09/11 Qty Unit Charge Per Extension ' ---------------------------- BASE FEE =---------=------------------------------------- 15.00 Permit . . . . MECHANICAL Application Number . . ... 11-00000192 Permit . . MECHANICAL Additional desc . Permit Fee 201.00, Plan Check Fee 50.25 Issue Date . . . . Valuation 0 Expiration Date 11/09/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 3.00 11.0000 EA MECH FURNACE >100K 33.00 4.00 16.5000 EA MECH B/C >3-15HP/>100K=500KBTU 66.00 11.00 6.5000 EA MECH VENT FAN 71.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . Permit Fee 282.75 Plan Check Fee . 70.69 Issue Date Valuation 0 Expiration Date,..-. 11/09/11 Qty Unit-Charge Per Extension BASE.FEE 15.00 25.00 6.000'0 EA PLB FIXTURE 150.00 1.100 15.0000 EA PLB BUILDING SEWER 15.00 8.00 6.0000 EA PLB ROOF DRAIN 48.00 2.00 7.5000 EA 'PLB WATER HEATER/VENT 15.00 1..00 -3.0000 EA, PLB WATER INST/ALT/REP 3.00 ' 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 17.00 .7500 EA PLB GAS PIPE.>=5 12.75 1.00 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments 6317 SF SFD. (LIVING = 5227SF ATT. CASITA = 1090SF) TYPE`V-B CONSTRUCTION W/ FIRE SPRINKLERS,R-3 OCCUPANCY.,2010 ` CODES. 2008 DIF: **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA,,BBQ'S and DRIVEWAY APPROACH** -------------------- Other.Fees . . . ----------------------------------------- ART IN PUBLIC PLACES-RES 899.37 BLDG STDS ADMIN (SB1473) 23.00 DIF COMMUNITY CENTERS-RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE• • 144.27 DIF FIRE PROTECTION-RES 140.00 DIF LIBRARIES = RES 355.00 LQPERMIT ' Application Number _, .11-00000192- 11-00000192---------------------- ---------------------------------------.------ Other Fees . . . . . . . ------------------------------ MULTI -SPECIES (MSHCP) FEE 1284.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 55.97 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 ^ Fee summary' Charged Paid- Credited Due Permit Fee Total 3011.85 .00 .00 3011.85 Plan Check Total _ 1637.02 1000.00 .00 637.02 Other Fee Total 6881.61 .00 .00 6881.61 Grand Total 11530.48 1000.00 .00 10530.48 , LQPERMIT . .. P.O. BOX 1504 Building /L7CLE TAMPIO)�q,/rT r%�A�UINTACALIFORNIA 92 253Address Owner , Brvice � Har f en e- ka n+cv- Mailing Address 5:3-6(A ' ,�I (C( ( 0 City Zip Tel q225� b0 -1-.i leIcf1 UUi ni CI AUI Address J� A �O D'E'S "�' r�,�%47 `�cclmS'�- z1p�221 l 1 Ido 6 Z® State Lia/-��, & Classif. vJ �j City ggct.7 I Lic. # Arch., Engr. Designer�-fa n M�YICiQ A Nor v U r °moi intDr 60 40(? qeq City, s 1,Li.%i1')`�C-[ Zip, r1 nt53 State Lic. # I hereb 1 a sed u er ro ' i sof er 9 (commencing with Section 00P Division 3 Busi ss ro ons C ,and my license is in�d/o a and v /OWNER -BUILDER DELAR�Pi ereby affirm that I am exempt from the CoCnti tor'sON License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this Permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT APPLICATION ONLY BUILDING: TYPE CONST. pe _1;' OCC. GRP. 5 1 n J� t IJ A.P. Number -1, 12)o Ole 52re M C3 327 Legal Description `� S �� L Project Description -9 ncl I>° �M i , v� ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE (Sq. Ft.0" SI s Size No. l No. Dw. Stories Units I New), Add ❑ Alter ❑ Repair ❑ Demolition ❑ !p Estimated Valuation 6 2-9vo 4. 00 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure 141r "CJ TOTAL1'?', f REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE Issued by: Validated by:— Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only .DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVELTWOAMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE:' - RECEIPT: CHECK#: - INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: EThe_Hidea Date: May 13, 2011, Owner's Name: Bruce &Marlene Kanter Phone No. 760-773-5205 Project Address: 80-429 Via Pessaro, LaQuinta Project Description: Single Family Dwelling APN: 777-180-018 Tract #: Lot #'s: Type of Development: Residential IXX Commercial Industrial Total Square Feet of Building Area: 6317 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above'iriformation is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to s' on behalf of the er/developer: I Dated: May 13, 2011 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN. OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project- -Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of'Sq.Ft. 6317 Amount per Sq.Ft. $2.97 Amount Collected $18761.49 Building Permit Application Completed: Yes/No: ' By: Jamie T. Brown, Asst. Supt., Business Services Certificate issued by: Laurie Howard, Secretary Signature: neap NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government. Code asserted by Assembly Bill.3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in, the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the dateyof issuance. Extension_ will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:clmydoes/dev lees -certificate o l7 compl iance 11/2010 P- Apr 28 11 11:54a • Bruce Kanter O FE'(CJF_- - 760-777-8191 p.1 RECORDING REQUESTED BY: Advantage Title, Inc. When Recorded Mail Document To: Bruce and Marlene Kanter as trustees of the Kanter Family Revocable Trust dated 10/611991 53664 Via Bellagio La Quinta, CA 92253 • r Escrow No.: 541 -1000098 -CB Title No.: 510-1001339-50 DOC # 20'10-0610935 12/21/2010 11:20A Fee:15.00 Page 1 of 1 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder 11111111111111111111I I1111111111 IN 1111111111111 11E S R U PAGE SIZE DA MISC LONG RFD COPY M A L 465 426 PCO NCOR SMF NCHG E� l��(-'�J T; CTY UNI 16- APN: 777-180-018 j rw('� \ kJ o GRANT DEED The undersigned grantor(s) declare(s) Documentary transfer.tax is $566.50 0 computed on full value of property conveyed, or 9 computed on full value less value of liens or encumbrances remaining at time of sale, O� o_ c r �u to FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Ellis J. Alden, trustee of the Ellis J. Alden Residence Trust, as his separate property hereby GRANT(S) to Bruce Kanter and Marlene Kanter, as trustees of the Kanter Family Revocable Trust dated 10/6/1991 as to an undivided 49% interest and and Stuart Weiser and Anna Weiser, husband and wife as community property, as to an undivided 51% interest, all as joint tenants the following described real property: PARCEL 1: LOT 272 OF AMENDED TRACT NO. 29894-2 AS SHOWN ON A SUBDIVISION MAP RECORDED ON DECEMBER 12, 2002, IN BOOK 327, PAGES 56 TO 88 INCLUSIVE, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER. PARCEL 2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION Dated: Ellis J. Alden, tr*►ort„!lis J. Alden Residence Trust State of Caomia _ .... .: _..... as his se _ property County : z kk O 1 'C'__ l -t , i7)ON G before me, } r � ,N Notary Public, personally appeared - � . who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. Witness my nd and offi ial se f�1 Signatur �� ��, (Seal) WUNDEfi DCAMPO COMmissiOn * 1834482 Notary Public - callfomis San Mateo County IO -Mg Comm. EXPIres Feb 28, 2013 Apr 2b 11 11:54a Bruce Kanter 760-777-8191 p.2 RECORDING REQUESTED BY: Advantage Title, Inc. DOC # 2010-0610936 12/21/2010 11:20A Fee:25.00 Page 1 of 1 /L Recorded in Official Records V�} county of Riverside When Recorded Mail Document To: Larry U. ward Bruce Kanter Trust Assessor, County Clerk &I`Recolyd`er Via Bellagio La Qu I I�I�II �IIII�I i�lll lf�� h�I II�I`I� �I�ll IV� I�11I Ifl� l��l La Quetta, CA 92253 S R U PA E SIZE DA MISC LONG RFD COPY Escrow No.: 541-1000098-CB Title No.: 610-1001339-50 M A L Z5 426 PCOR CO S NCHG EXA" APN: 777-180-019 T: CTY UNI GRANT DEED cantors declares Documenfa-- transfer taxis $-0- Returning property to the joint tenants or The undersigned g (} (} ry no consideration of a sales price ❑ computed on full value of property conveyed, or computed on full value less value of liens or encumbrances remaining at time of sale, ❑ Unincorporated area: Q39 FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Stuart Weiser and Anna Weiser, husband and wife as community property hereby GRANT(S) to Bruce Kanter and Marlene Kanter, trustees of the Kanter Family Revocable Trust dated 10/6/1991 the following described real property: PARCEL 1: LOT 272 OF AMENDED TRACT NO. 29894-2 AS SHOWN ON A SUBDIVISION MAP RECORDED ON DECEMBER 12, 2002, IN BOOK 327, PAGES 56 TO 88 INCLUSIVE, OF MAPS, IN THE OFFICE OF THE. COUNTY RECORDER. PARCEL 2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EG AINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED 1 55to ON Dated: December 3, 2010 Xnna eiser State of CaliforniaCountyof R]ypr�;aAOn gi, gni n -_ _ before me, eiser Notary Public, personally appeared 4 t is r r wp i nr a nd and Anna Weiser — who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that helshelthey ROSE GONZALEZ executed the same in his/her/their authorized capacity(ies), Commisslon.# 1618067 and that by hislher/their signature(s) on the instrument the Notary Pubft • Calltotnle D person(s), or the entity upon behalf of which the person(s) Riverside County acted, executed the instrument. My Comm.'Ex fres Oct 18, 2012 I certify under PENALTY OF PERJURY under the laws of the State of Califor ' the fore oing paragraph is true and correct. ' Witnes. h nd and i 'ial seal. Signature (Seal) May 12, 2011 Mr. and Mrs. Bruce Kanter ' 53-664 Via.Bellagio La Quinta, CA 92253 RE: Kanter/ Preliminary Design Submittal Lot 272 at. 80429 Via Pessaro Dear Mr. and Mrs. Kanter: The Hideaway'Design Review Committee met to discuss the roof modification presented with regard to your final working drawing submittal for the proposed residence at Lot 272. In addition, we appreciate the time spent with you,andyour design team, discussing the plan sT-he:pr-oject-hasQbeen approved Rnd constr_uction-may b.egini after a Pr e_ -Con struction Meeting `is held on. site. Our discussion topics have been noted -below for confirmation. The small, flat roof on the right side of the street elevation, as well as the two flat roof . areas shown at the Entry Gates, have been modified per: the committee's previous request. With regard to landscape, the lighting 'guidelines which limit .the number of up dight fixtures have been eased. If you would like additional lighting, please submit a revision to the committee' for consideration. In addition, Gerry Tarsitano will need to review and approve the tree location near the BBQ. We appreciate the inclusion of an additional tree in this area. You may want to consider adding an additional Olive tree near the end of the garage #2 to provide screening from the golf cart path as well. As a follow-up to the meeting the committee has approved the picture windows as presented in the plans. However, the DRC does not feel they are in a position to recommend 'approval .of the removal of mullions completely from the two windows as requested. As noted in the meeting, the.°committee has recommended in the past, that the requirement for mullions be removed from the guidelines but the membership has voted to keep the guideline requirement. You have the right to appeal the DRC decision to the Board of Directors regarding the use of a minimal, mullion design, as this is the Request for Variance process. In addition, your request to add a door at the Golf Cart Garage appears to be acceptable, however, is subject to a revised plan being submitted for review. As a reminder, any deviation from the Design Guidelines must be submitted with a request for Variance. If a design element is not presented as a Variance request and the committee inadvertently overlooks it during the review process it will be the design team's responsibility to make modifications at a later date if requested by the Design Review Committee. Thank you again for your, feedback regarding the process.' The DRC looks forward to working with you during the construction of your home. Please contact Roxi Bardwell. at (760) 393-5211 with any questions. We look forward to receiving your next set of plans for review. Sincerely, Hideaway Design Review Committee cc: bekanter aol.com; Lance Fedderly; Gerry Tarsitano; DRC File May 5, 2011 Mr. and Mrs. Bruce Kanter, 53-664 Via Bellagio La Quinta, CA 92253 RE: Kanter Pre -construction meeting Lot 272 at 80429 Via Pessaro . Dear Mr. and Mrs. Kanter: The Final Working Drawings have been approved by the Design Review Committee with. comments that will follow in a separate letter. The Hideaway Design Review Committee appreciates the time your contractor took at our Pre -Construction meeting on May 4,' 2011. Per our meeting in. the field, items that will need to be furnished prior to the start of construction, as well as various discussion notes are listed below: • A reduced set of the City of La Quinta (stamped) approved -plans are required. • A copy of your building permit will need to be delivered to Roxi Bardwell. • A construction deposit in the amount of $15,000 will need to be delivered to Roxi Bardwell within one (1) week of the Pre -construction meeting. • Please contact the Golf.Course superintendent" Gerry Tarsitano at 760-275-6893 prior to grading the side and rear of the lot.pad. • Locate. stub ups for all utilities. • A tan port -o -potty and tan trash receptacle will be brought on site. • The construction trailer must be tan in color: • Chain link fence with tan shade cloth across the back of the lot and running towards the curb will be installed at the rear property line with a termination, at the curb before construction can begin.. Third party agreement lots must be fenced with the same material no more than 2/3 back from the curb. • You are in receipt of the Construction Guidelines. Please provide copies to your sub -contractors as well. The construction gate is located on Avenue 52., The Hideaway adheres to the City of La Quinta's construction hours. At no time is construction traffic allowed to enter or exit through the Jefferson Gate. The Superintendent may work earlier. or later, in their trailer, if notification is given to Security in advance. • Construction meters must be obtained by contacting IID and CVWD. • Construction signage is elective and must adhere to the guidelines. However, as a safety precaution it's suggested that you utilize a sign with the emergency contact number. The builders name may be included on the sign. • A sub -contractor access list will be provided for use by Security. •. Dust Control was discussed. Dust control will be provided 24/7 as necessary. • The speed limit must be adhered to throughout the property. You are responsible for your sub-contractors. • No on-site dumping is permitted; this includes the Hideaway's stock pile. area near Madison and Avenue 52. • A setback meeting and survey report, exterior color board inspection and final walk through inspections will be requested by you at the appropriate times. • The Hideaway will remove any irrigation pipes that remain on the lot. • Please be aware that the Hideaway is utilizing a transponder program and ' all contractors and subs will be required to participate. The Hideaway will also enforce the provisions of Chapter Seven of the Design Guidelines, which govern the activities of contractors and subs onsite. Citations that are issued to subs for violations are ultimately the responsibility of the owner. . •. Dig Alert.should be notified of your intention to start construction. Any repairs of infrastructure due to damage caused by your staff or sub-contractors will be billed back to you by the Association. • Hand dig in P.U.E and Community Landscape area- • Ramp curbs to protect from damage.or be charged.for repairs. Minimal damage was photographed at the meeting on 5/4/11. • Protect asphalt street `from damage 'from heavy equipment as needed or be charged for repairs. • The Contractor Agreement form was signed _At the Pre-Construction meeting. Again, please contact the Golf Course Superintendent, Gerry Tarsitano, prior to grading. Please contact Roxi Bardwell at (760) 393-5211 or rbardwell(a),drminternet.com with any questions or concerns. Sincerely, . Hideaway Design Review Committee CC: Lance Fedderly, Gerry Tarsitano, Hort Tech, Security, DRC File; bekanter@a ol.com; May 12, 2011 Mr.. and Mrs. Bruce Kanter 53-664 Via Bellagio La Quinta, CA 92253 RE: Kanter/ Preliminary Design Submittal Lot 272 at 80429 Via Pessaro Dear Mr. and Mrs. Kanter: The Hideaway Design Review. Committee met to discuss the roof modification presented, with regard to your final working drawing submittal for the proposed residence at Lot 272. In addition, we appreciate the time spent with you, and your design team, discussing the plans. The project has been approved and construction may begin after a Pre -Construction Meeting is held on site. , Our discussion topics have been noted below for confirmation. The small, flat roof on the right side of the street -elevation, as well as the two flat roof ureas shown at the Entry Gates, have, been modified per the committee's previous request: With regard to landscape, the lighting guidelines which limit the number of up light fixtures have been eased. If you,would like additional lighting, please submit ' a revision to the committee for consideration. In'addition, Gerry Tarsitano`will need to review and approve the tree location near the BBQ. We appreciate the inclusion of an additional tree in.this area. You may. want to consider adding an additional. Olive tree near the end of the garage #2 to provide screening from the golf cart path as well. As a follow-up to the meeting the committee has approved the picture windows as presented in the plans. However, the DRC does not feel they are in a position .to recommend approval of the removal of mullions completely from. the two windows as requested. As noted in the meeting, the committee has recommended in the past, that the requirement for mullions be removed from the guidelines but the membership has voted to keep the guideline requirement. You have the right to appeal the DRC decision to the Board of Directors' regarding the -use of a minimal mullion design, as this is the Request for'Variance process. - In addition, your request to add a door at.the Golf Cart Garage appears to be acceptable, however, is subject to a revised plan being submitted for review. As a reminder, any deviation from the Design Guidelines must be submitted with a request for Variance. If a design element is not presented as a Variance request and the committee inadvertently overlooks it during. the review process. it .will be the design team's responsibility to make modifications at -a later date. if requested by the Design Review Committee. - Thank you again for your feedback regarding the. process. The DRC looks forward to working with you during the construction of your home. Please contact Roxi.Bardwell at (760) 393-521.1 with any questions. We look'forward to receiving your next set of plans for review. Sincerely, Hideaway Design Review Committee cc: bekanter@aol.com; Lance Fedderly; Gerry Tarsitano; DRC File- PROUDLY SERVING THE UNINCORPORATED AREAE OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS - RANCHO MIRAGE RuBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT I JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 �FIrC$. I> IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 922114131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org March -14,2011 Act First Fire Protection 1325 N. Red Gum #10 Anaheim, CA 92806 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE `i ' 2Dtl By SS .I Re: Residential Fire Sprinkler Plan Review The Kanter Residence Lot 272 at the Hideaway The above referenced sprinkler plans have been reviewed and are acceptable by the Riverside County Fire Department and are approved with the following conditions: - r 1) Approval of these plans does not include the piping of the underground system. 2) Permanently marked identification signs shall be attached to all control valves. 3) A sign shall be located adjacent to the alarm bell worded as follows: SPRINKLER FIRE ALARM - WHEN BELL RINGS CALL 911 4) A warning sign, with minimum -'I/4 inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING:. The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automaticallysshut off the water to the fire sprinkler system, such as water softeners, filtration sysfems, and automatic shut-off valves, shall not be added to this system without-,a:review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. 5) Refer to Approved fire sprinkler plans for "red -lined" change to riser detail. NFPA13D 1.1.2 (3) :, The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure: (b) Fire Riser Flush (c) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection. Sincerely, By Jason Stubble Fire Safety Specialist BY Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/29/2011 -Electronically Signed at CalCERTS.com by Yolanda Mendoza (Mendoza Design) 7/15/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Rear (N). 8.1 9 0.250 Kanter Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 3/24/2011 Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Stories . 0 41 none t none �' Bug Screen Lot 272, The Hideaway La Quinta CA Climate Zone 15 6,259 n/a 1 New. FIELD INSPECTION ENERGY CHECKLIST Left 2641 'e 0.250 (� a r - , �+ ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. no ; Bug Screen ��x` yNew El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. Skylight x , x'20 0�, 0.550'0 39 none(rioneY .r ,, None INSULATION Area Special . Construction Type Cavity (ft) Features see Part 2 of 5 Status none Bug Screen Roof Wood Framed Attic R-38 6,222 Radiant Barrier New Wall Wood Framed R-21 4,877 New i? Iib F/aTMh7e'M -on-Grade None 6,259 Perim = 573' New BY FENESTRATION "=`U. Exterior Orientation: Area.(ft'Factor SHGC Overhang Sidefins Shades Status Rear (N). 8.1 9 0.250 0.41 none none Bug Screen New Rear (N) .. 48 0 0.250w; 0 41;4 Oj, ..4 0/4 0 . ;:Bug Screen.,„, New Ri fit E 1` trF 191 2 0 250' 9 O.: " . 0 41 none t none �' Bug Screen New a Front (S) •, < ;; .; : 74 8 f. 0.2$0 $ z 0 41 none .., -: none ,, °Bug Screen ': _ New. Left 2641 'e 0.250 (� a r - , �+ ;041, ,none no ; Bug Screen ��x` yNew Skylight x , x'20 0�, 0.550'0 39 none(rioneY .r ,, None Rear (Al) 48.0 `, 0.250 :D 41. .•hone none Bug Screen New 80 0 0:2500.41 10.0 none Bug Screen New Front (SlAq 90:0:: `' 0. 250 0.41 none none Bug Screen New Left (NVlq 36.0' 0.250 0.41 none none Bug Screen New Skylight '1:7 5 `0.550 0.39 none none None New - HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status e. 1 Large Gas 100 0.80 Recirc/Time+Temp New 1 Large Gas 75 0.80 Recirc/Time+Temp New EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011.02-04710:39:33 ID: Pae 1 of 9 Reg: 211-N0015942A-000000000-0000 Registration Date/Time: 2011/03/29 18:12:13 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/29/2011 0 Electronically Signed at CalCERTS.com by Yolanda Mendoza (Mendoza Design) 7/15/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kanter Residence Building Type m Single Family ❑ Addition Alone ' ❑Multi Family ❑ Existing+ Addition/Alteration Date 3/24/2011 Project Address Lot 272, The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,259, Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures --'If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No: Special Features' --'If Yes, see Part,2 of 5 of this'form for'details. INSULATION . Area Special - Construction Type Cavity #t) Features see Part 2 of 5 Status ' FENESTRATION t' . '..:U- '` Exterior Orientation_ ;;Area(ftz) Factor SHGC Overhang Sidefins Shades Status Rear (N) f 276 0 V:_ :0.250 0.41 4.0 none Bug Screen New Front (S) 80 00 250: ".0 41 2 O y ,none �t3ug Screen, .; . New e -."mo i^ tae.,. * '240.6; Front (S) j' ;:, ) . f : 240 0 x 0 250 ` 0 41 . 20 0 4,>, �, none Bug Screen �r : ; New Left (SFVI� Fy 80 0 �x 0 250. 0 41 X10 0 r ?"none t =,Bug Scieen ' " "`Newer. Left (S4lM ° 2. f 00 OX�`?, 0$250 �0�41 6 0 r� ¢ 'none 4'Bug Screen E .ra R. ,r �rNew �, HVAC SYSTEMS Ot . Heating Min. Eff 4 Cooling Mina Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION` Duct Location HeatingCoolin Duct Location R -Value' Status.' HVAC 4 Ducted , Ducted , Attic, Ceiling Ins, vented 8.0 New f WATER HEATING - Ot T e Gallons Min.,Eff . - Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-02.04710:39:33 ID: Page 2 of 9 Reg: 211-N0015942A-000000000-0000; Registration_ Date/Time: 2011/03/29 18:12:13 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com — 3/29/2011 Electronically Signed at CalCERTS.com by Yolanda Mendoza (Mendoza Design) 7/15/2011 I PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Kanter Residence ❑ Multi Family ❑ Existing+Addition/Alteration 1312412011 SPECIAL' FEATURES INSPECTION CHECKLIST - The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-I-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. A hot water recirculation systems has been modeled.. Verification of type is required. .. HIGH MASS Design - Verify Thermal Mass: 930.0 ftz Covered Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 164.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3 The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 stand each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,129.0 ft, Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 486.0 ftz Exposed Slab Floor, 3.500" thick at Master Suite The DHW System Bradford White,#M-1-75S6BN is a non-NAECA large storage gas water heater. Verify DHW details. A hot water recirculation systems has been modeled. Verification of type is required. The-:H.VAC: System HVAC 3 must'serve;on/y. Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se urate thermostat. In addition the airflow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASSDesign -, Verify,. Thermal Mass 137.0 ft' Covered Slab Floor, 3.500" thick at Living/Kitchen 3 0 thick at Living/Kitcfhen 't., HIGH MASS06sign'^Verify Thermal Mass r1 584 0 ft'Exposed Slab Floor, 50 # i`- . '� The HVAC °System HVAC 4 must,servef !only Sleeping Areas rThe non closable areaibetw_een zones cannot exceed 40 sf and.each zone must have a r'.e'u,r.e+ments to ResidL enaA en�dix:;+RwAa -6 must be.met..� , -- separate thermostat. In add�iti;on tKhe•+. air 'fl:ov winreNudi;r. ements'and fadn.,-watt draw HERS�REQUIRLED VERIFICATION_ r Nom -A atiMr-..�rr a i , M. "� Y "�- r:':" K�.a- iL"E?'��'<.,-. .F` i:ati y,'i' Items ln•this section require field testing and/or,venflcation by a certlfledkHERS Rater =The lnspector4must receive a mea u listed below'for;f'inal to:be" (ven:'_" completed CF74R form':.;for:each`of fire es The: Cooling. System C,amer 24ACA448/58CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the co e t Condenser s ^,� The HVAC System' HVAC '1 incorporates`HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates. HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified critena The Cooling System Carrier 24ACA460158CVX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. . I ' - } • ' The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.. ' The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. `' •' The Cooling System Carrier 24ACA460158CVX110 includes credit for a'12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA460158CVX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. ' The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. • , ,. y b _ r Ene Pro 5.1 by EnemySoft User Number., 6712 RunCoder 2011-02-04710:39:33 ID: Page 3 of 9 Reg: 211-N0015942A-000000000-0000, Registration Date/Time: 2.011/03/_29 18:12:13 ,HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott,and Authenticated at CalCERTS.com - 3/29/2011 Electronically Signed at CalCERTS.com by Yolanda Mendoza (Mendoza Design) 7/15/2011 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Kanter Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1312412011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification,"and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 606.0 ft2 Exposed Slab Floor, 3.500" thick at Dining HIGH MASS Design - Verify Thermal Mass: 233.0 ft2 Covered Slab Floor, 3.500" thick at Media/HalIlLaundry HIGH MASS Design - Verify Thermal Mass: 589.0 ft2 Exposed Slab Floor, 3.500" thick at Media/Hall/Laundry HIGH MASS Design - Verify Thermal Mass: 329.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 4 , HIGH MASS Design - Verify Thermal Mass: 72.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 4, The Roof R-38 Roof(R.38.2x12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. .. l .:"..,: .. ..7. 1 k .. �. , x^�:• . +L.; f.; '�A�..a �f �:., ,.;iP w 1.''1f +A •; ak Tw. 1.sn. ..+. R� �,p l+ A'S'E HERS`REQUIREDHVERIF�ICATIOIV�. ° ��-- Items"in tl is:sectioh require.fleld testingyandior ve I icatlon by a certified HERS Rater eymspector must receive a com IeCed CF -4'R form;for eachtof the°measures'listed below for.fmal to.be Ives: r"' 14 • - ., "V, !� r - y _ . fit, .. _. •' EneMyPro 5.1 by EneMySoft User Number: 6712 RunCode: 2011-02-04T10:39:33 ID: Pa e 4 of 9 Reg: 211-N0015942A-000000000-0000 Registration Date/Time: 2011/03/29 18:12:13 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 3/29/2011 • Electronically Signed at CalCERTS.com by Yolanda Mendoza (Mendoza Design) 7/15/2011 r PERFORMANCE CERTIFICATE: Residential (Part 3 of 5 CF -1 R Project Name Building Type m single Family ❑ Addition Alone Date Kanter Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1312412011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV , kBtu/ft2- r Space Heating 4.12 2.22 1.91 Space Cooling- 54.81 46.86 7.95 Fans 11.40 13.65 -2.26 Domestic Hot Water : 5.83 5.30 0.53' Pumps 0.00 0.18 -0.18 i Totals 76.16 68.20 7.95 Percent Better Than Standard: 10.4 BUILDING COMPLIES .- HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (s) - 1,206 485 u Fuel Available at Site: Natural Gas (tM 1,892 480 Raised Floor Area: 0, (N) 1,676 454 Slab on Grade Area: 6,259 (E) 1,793 271 Average Ceiling He ht F� ` r° 11.2 .. Roof 6,259 38 Fenestration Averag"e,U-Factor': 0.25 TOTAL: L728 Avera e;SHGC: ' 0.41 Fenestration/CFA Ratio: 27.6 REMARKS-.--, r :The. Hideaway Lot 176 i i � L � b „ ;. 1• �i it .,� i k � � �i u�4- � •, �.# ;'. � � 4 � .. ^ l •+ -? v7� Y°'7•( N # g�r'Rp t � Fid, � L �J �t - i _.:••�.++,.F,#� d.p, -' •F � ��� � �, � ,[ �w .,r,A tack "�,+-"F ,# a,y ,%,.,,,,,..-•..R+ '1` �, `; bii .i f � �>.."�,.`.', �...`_ ��' �, M'fi ';*�� Lx+�S'....^I'• rr' ,.wP P$f' 4' �'+5. i'£, _ STATEMENT.OF COMPLIANCE This certificate of compliancelists the building features and specifications needed to comply with Title 24;.Parts' 1 the Administrative Regulations and Part 6 the Efficiency Standards of.the`California Code of Regulations. _ The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 3242011 Address 77-085 Michigan Drive;, ,0 Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Mendoza Design Address 79-010 Victoria Drive Name Manual or Yolanda Mandoza City/State/Zip La Quinta,.Ca 92253 Phone (760) 610-2933. °• Signed. License # Date Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-02-04T10:39:33 /D: Page 5 of 9 Reg: 211-N0015942A-000000000-0000 Registration Date/Time: 2011/03/29 18:12:13 HERS Provider:-Ca10ERTS, Inc Electronically.Filed,-by Tim Scott and Authenticated at Ca10ERTS.com - 3/29/2011' ' Electronically Signed at Ca10ERTS.com'by Yolanda Mendoza (Mendoza'Design) 7/15/2011 r Reg:,211-N0015942A-000000000-0000 Registration Date/Time:2011/03%29 18:12:13 HERS 'Provider: CalCERTS, Inc q 1 •.. jy, , i . 1 ��,�'! �'� ," � ^; ^k• J rii 1. ,• CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5), CF -1 R Project Name , e Building Type m Single Family .❑ Addition Alone Date Kanter Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1312412011 OPAQUE SURFACE DETAILS Surface U- Insulation ,y, Joint Appendix ! Type Area Factor CavityExterior Frame Interior Frame Azm Tilt " Status 4 Location/Comments Roof 1,094 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 2 & 3 Wall 362 0.069 R-21 v 0 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 431 0.069 R-21 90 90 New 4.3.1-A6 .. Bedroom 2 & 3 Wall 132 0"069 R-21 180 90 New -: -.4.3.1-A6 " -. .. Bedroom 2 & 3 Wall 367 0.069 R-21 270 90 New. 4.3.1-A6 Bedroom 2 & 3 - Slab 930 0.730 None 0 180 New 4.4.7-A1 ," Bedroom 2 & 3 Slab '164 0.730 None r 0 180 New 4.4.7-A 1 Bedroom 2 & 3 Roof 1,595 0.026 R-38 0 0 New- 4.2.1-A9 Master Suite Wall 232 0.069.R-21 22 `90 New 4.3.1-A6 Master Suite Wall ..' 173 0.069 R-21 126 90 New 4.3.1-A6 Master Suite Wall 107 . 0.069 R-21. 180 90 New 4.3.1-A6 Master Suite Wall 111 0.069 R-21. .216 90 New 4.3.1-A6 Master Suite Wall 291 0.069 R-21 s 270 90 New 4.3.1-A6 - Master Suite Wall .182 0.069 R-21 306 90 New 4.3.1-A6 . Master Suite Slab 1,129 0.730 None 'O 180 New 4.4.7-A1 Master Suite Slab 486 0.730 None 0 180 New 4.4.7-A1 Master Suite FENESTRATION SURFACE DETAILS o ID Type Area :; I Tactor SHGC Azm ` Status GlazingType Location/Comments • 1 Window 15.0. ; 0.250 NERC 0.41 NFRC ,. 0 New Loewen Windows Bedroom 2 & 3 ;,2 �s Window ... 21 9 .0.250 NFRC_ 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 3 . ' Window �• x''15 0 < 0:250 NFRC ' 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 C -A, Window 48.01`0.250 NFRC';.. 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 :5'+ Window, , �„ W_r 15.0 0.250 NFRC 0 41 „NFRC• _ _ _.0 New__ ,, , .Loewe.n.Win_dows ,_ ,. Bedroom 2 & 3 °.6 *: Windo""w "> 11.,3' 0.250 °NFRC;, is 0:41" NFRC,, M =190 New,% Loewen Windows Y-��,• ���'Bedroom 2 & 3 J' Window :: ` 148.0 0.250 .NFRC"• 0.41 'NFRCa + .x90 NeW1„ Loewen Windows6�.:.a��.` Bedroom 2,&.3 , r 8 Window.;.; 48:0 X0.250 NFRCu`f 0.4.1 NFRC �:.;',180:'New, `Loewen Windows+ V, r ''. Bedroom'2&'3.- 9 Window ;:. 4810 ,1,0.250, NFRC } ; 0.41., NFRC, ? :270 News,., Loewen;Windows >3, x Bedioom 2 10 Skylight:: �#',�20.0,1";0.550"NFRC,; w;:�.0.39`NF„RC?�' ,,� OfNew�«�.�;.�Skylight�.�-, ���,'� � r%�:,MasterSuite,r�,�' 11•" Windows :; 48:0 0.250 NFRC ; aO.Ai;'NFRC, #. X22 New r',YN Loewen Windows �< ; ;Master.Suite ?! i 12ndowl' 80.0 .`:0.250 NFRC"x4 0.41` NFRC?.:ro?�'126 New„"r i Loewen Windows .. ;.;G Master Suite ' 13 .: Window 8.8::: =0.250 NFRC :' 0.41' `NFRC 180 New Loewen Windows Master Suite 14 Window i. X90.0 ',:. 0:250 NFRC'- 0.41 NFRC 216 New- Loewen Windows Master Suite (.15 Window k :: ;.c,11 3 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite Window 24.0, r 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite - t -,. (1) U -Factor Type 6116 A'= Default Table from Standards, NFRC =Labeled Value f 2 SHGC Type: I-.: 1.16-8'=Default Table from Standards, NFRC =Labeled Value - 'EXTERIOR SHADING DETAILS :+ Window Overhan - Left Fin Ri ht Fin ID Exterior Shade Type SHGC Hat Wd Len Hat LExt RExt Dist Len Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 ?- " 4 Bug Screen 0.76 8,0 _ 6.0 4.0 0.1 4.0 - " 4.0 0.1 4.0 0 0.1 4.0 0 5 Bug Screen 0.76 6 Bug Screen 0.76 ' 7 • Bug Screen 0.76 8 Bug Screen 0.76 9 Bu Screen .0.76 r, _ 10 None 1.00 ' 11 Bu Screen 0.76 ) 12 Bug Screen 0.76 10.0 8.0 10.0 0.1 10.0 10.0 f 13 Bug Screen 0.76 14 Bug Screen 0.76 z r 15 Bu Screen 0.76 16 Bug Screen - 0"76 ' Ene Pro 5.1 b Ene Soft User Number: 6712 .. '. Run Code: 2011-02-04710:39:33 ID: - ' Page 6 of 9 r Reg:,211-N0015942A-000000000-0000 Registration Date/Time:2011/03%29 18:12:13 HERS 'Provider: CalCERTS, Inc q 1 •.. jy, , i . 1 ��,�'! �'� ," � ^; ^k• J rii 1. ,• CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5), CF -1 R Project Name , e Building Type m Single Family .❑ Addition Alone Date Kanter Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1312412011 OPAQUE SURFACE DETAILS Surface U- Insulation ,y, Joint Appendix ! Type Area Factor CavityExterior Frame Interior Frame Azm Tilt " Status 4 Location/Comments Roof 1,094 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 2 & 3 Wall 362 0.069 R-21 v 0 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 431 0.069 R-21 90 90 New 4.3.1-A6 .. Bedroom 2 & 3 Wall 132 0"069 R-21 180 90 New -: -.4.3.1-A6 " -. .. Bedroom 2 & 3 Wall 367 0.069 R-21 270 90 New. 4.3.1-A6 Bedroom 2 & 3 - Slab 930 0.730 None 0 180 New 4.4.7-A1 ," Bedroom 2 & 3 Slab '164 0.730 None r 0 180 New 4.4.7-A 1 Bedroom 2 & 3 Roof 1,595 0.026 R-38 0 0 New- 4.2.1-A9 Master Suite Wall 232 0.069.R-21 22 `90 New 4.3.1-A6 Master Suite Wall ..' 173 0.069 R-21 126 90 New 4.3.1-A6 Master Suite Wall 107 . 0.069 R-21. 180 90 New 4.3.1-A6 Master Suite Wall 111 0.069 R-21. .216 90 New 4.3.1-A6 Master Suite Wall 291 0.069 R-21 s 270 90 New 4.3.1-A6 - Master Suite Wall .182 0.069 R-21 306 90 New 4.3.1-A6 . Master Suite Slab 1,129 0.730 None 'O 180 New 4.4.7-A1 Master Suite Slab 486 0.730 None 0 180 New 4.4.7-A1 Master Suite FENESTRATION SURFACE DETAILS o ID Type Area :; I Tactor SHGC Azm ` Status GlazingType Location/Comments • 1 Window 15.0. ; 0.250 NERC 0.41 NFRC ,. 0 New Loewen Windows Bedroom 2 & 3 ;,2 �s Window ... 21 9 .0.250 NFRC_ 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 3 . ' Window �• x''15 0 < 0:250 NFRC ' 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 C -A, Window 48.01`0.250 NFRC';.. 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 :5'+ Window, , �„ W_r 15.0 0.250 NFRC 0 41 „NFRC• _ _ _.0 New__ ,, , .Loewe.n.Win_dows ,_ ,. Bedroom 2 & 3 °.6 *: Windo""w "> 11.,3' 0.250 °NFRC;, is 0:41" NFRC,, M =190 New,% Loewen Windows Y-��,• ���'Bedroom 2 & 3 J' Window :: ` 148.0 0.250 .NFRC"• 0.41 'NFRCa + .x90 NeW1„ Loewen Windows6�.:.a��.` Bedroom 2,&.3 , r 8 Window.;.; 48:0 X0.250 NFRCu`f 0.4.1 NFRC �:.;',180:'New, `Loewen Windows+ V, r ''. Bedroom'2&'3.- 9 Window ;:. 4810 ,1,0.250, NFRC } ; 0.41., NFRC, ? :270 News,., Loewen;Windows >3, x Bedioom 2 10 Skylight:: �#',�20.0,1";0.550"NFRC,; w;:�.0.39`NF„RC?�' ,,� OfNew�«�.�;.�Skylight�.�-, ���,'� � r%�:,MasterSuite,r�,�' 11•" Windows :; 48:0 0.250 NFRC ; aO.Ai;'NFRC, #. X22 New r',YN Loewen Windows �< ; ;Master.Suite ?! i 12ndowl' 80.0 .`:0.250 NFRC"x4 0.41` NFRC?.:ro?�'126 New„"r i Loewen Windows .. ;.;G Master Suite ' 13 .: Window 8.8::: =0.250 NFRC :' 0.41' `NFRC 180 New Loewen Windows Master Suite 14 Window i. X90.0 ',:. 0:250 NFRC'- 0.41 NFRC 216 New- Loewen Windows Master Suite (.15 Window k :: ;.c,11 3 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite Window 24.0, r 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite - t -,. (1) U -Factor Type 6116 A'= Default Table from Standards, NFRC =Labeled Value f 2 SHGC Type: I-.: 1.16-8'=Default Table from Standards, NFRC =Labeled Value - 'EXTERIOR SHADING DETAILS :+ Window Overhan - Left Fin Ri ht Fin ID Exterior Shade Type SHGC Hat Wd Len Hat LExt RExt Dist Len Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 ?- " 4 Bug Screen 0.76 8,0 _ 6.0 4.0 0.1 4.0 - " 4.0 0.1 4.0 0 0.1 4.0 0 5 Bug Screen 0.76 6 Bug Screen 0.76 ' 7 • Bug Screen 0.76 8 Bug Screen 0.76 9 Bu Screen .0.76 r, _ 10 None 1.00 ' 11 Bu Screen 0.76 ) 12 Bug Screen 0.76 10.0 8.0 10.0 0.1 10.0 10.0 f 13 Bug Screen 0.76 14 Bug Screen 0.76 z r 15 Bu Screen 0.76 16 Bug Screen - 0"76 ' Ene Pro 5.1 b Ene Soft User Number: 6712 .. '. Run Code: 2011-02-04710:39:33 ID: - ' Page Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 3/29/2011 --Electronically,Signed at CalCERTS.com by Yolanda'.Mendoza (Mendoza Design) 7/15/2011 a CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5)' CF -1 R Project Name r Kanter Residence Building Type m Single Family. ❑ Addition Alone ❑ Multi Family • ❑ Existing+ Addition/Alteration Date 3/24/2011 OPAQUE SURFACE DETAILS I _ ' Surface U- Insulation Joint Appendix - rype Area I Factor cavityTExterior Frame Interior Frame A Tilt Status 4 ._ Location/Comments Roof 1,7041 0.026 R-38 0 ' 0 New ,._ 4.2.1-A9 LivinglKitchen Wall 1151 0.069 R-21 0 90 New 4.3.1-A6 Livin Itchen . Wall 421 0.069 R-21 90 90 New 4.3.1-A6 LivingtKitchen Wall 170 0.069 R-21 180 90 New 4.3.1-A6, LivinglKitchen Wall 211 0.069 R-21 234 '_ 90 New - 4.3.1-A6 Livin Kitchen Slab 137 0.730 None _ 0 180 New 4.4.7-A 1 ' LivingXitchen Slab 1,584 0.730 None 0 180 New • 4.4.7-A1 LivinglKitch6n. Roof 606 0.026 R-38 0 0 New 4.2.1-A9 Dinin /Media.Bedroom 4 Wall124 0.069 R-21 0 90 New 4.3.1-A6 ' Dinin /Media.Bedroom 4 Wall - 223 0.069 R-21 90 90 New 4.3.1-A6 Dining/Media.Bedroom 4 Slab 606 0.730 None0.180 New -Al4.4.7 Dining/Media.Bedroom 4 Roof 822 0.026 R-38 0 r ' + ' 0 New 4.2.1-A9 Dining/Media. Bedroom 4 Wall 253 0.069 R-21. 0 90 New 4.3.1-A6 Dining/Media. Bedroom 4 Wall • 97 0.069 R-21 90 : 90 New 4.3.1-A6 ' Dining/Media. Bedroom 4 Wall 2011 0.069 R-21 180 , 90 New .. 4.3.1-A6,, Dining/Media. Bedroom 4 Wall 1 -3611 0.069 R-21 2701 90 New 14.3.1-A6 JDininglMedia.Bedroom 4 FENESTRATION SURFACE'.DETAILS ` ID Type Area ,/°U -Factor: SHGC Azm Status Glazing Type Location/Comments 17 Window 10.5: 's0 250 NERC _ 0.41 NFRC 270 New Loewen Windows Master Suite - ;;18, :; Window 11 3 '::0:250 NFRC. 0.41 NFRC 270 New Loewen Windows Master Suite 19, Window 15 0 :0.250 NFRC:- 0.41 NFRC, 270 New Loewen Windows Master Suite 20 Window ., , _> 6 0.::i 0 250 NFRC '• 0.41 NFRC 306 New Loewen Windows Master Suite 21 Window :_:30;0 0.250 NFRC ! p 41 NFRC - 306 New __ ,Loewen Windows .:, ,.. ,.,... Master Suite 22,, Skylights '517.,5 0.550 (NFRC mss, 039';NFRC, g#'O News Skylglit.t";sat.( Living/Kitchen 23 Window - - � 36:0' 0.250 .NFRC r '.`4 0.41 ` INFRC ; f ; • O New <M- ` Loewen Windows ' n : • Living/Kitchen 24 Window ::_ 240 0 �0 250, NFRC ` ;r 0.41 NFRCN 0 New, Loewen Windows Lrvin %Kitchen T .:-,... . , g 25 Window . 8114 x110 250 NFRC,# -'" 0.41: NFRC", , 1t70 :New' Loewen,Windows _; .Lrvrng/Kitchen rte; ,q :'. , 26 Window 2400;1&0.250 NFRC u'�0.41, NFRC''; ;180 rNewe; � 'Loewen:Wn,`dows Gwn /Kitchen" ` " •r-" 9, .. 2Z.'! Window f 80 0.0.250 NFRC �� ;ta0:41' NFRC' "."234 'New ' ; Loewen Windows ' °" 'Llvrng/Kifchen ; 28.= , Wndow , 400 0, X40.250 NFRC.'s,4. i ,10.41 NFRC �_r - 234 `New �K ;?: Loewen:Windows Living/Kitchen 29:. Window 15 0 `?;0.250 NFRC:..'..-. ..'0.4f;' NFRC 0 New Loewen Windows Dining/Media.Bedroom 4 . 1`30._- Window A,35 0 .,.,'.O.'250, NFRC.: 0.41 NFRC 90 New- Loewen Windows Dining/Media.Bedroom 4 -31 � , Wndow - ; 26 3 i, 0:250 NFRC:: - 0.41 NFRC _ 90 New Loewen Windows Dining/Media.Bedroom 4 32 ; Window 18 0;, 0:250 NFRC 0.41 NFRC 180 New Loewen Windows Dining/Media.Bedroom 4 (1) . U -Factor Type J 16-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: ] i64- Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS r ' Window r Ove hanq Left Fin Ri ht Fin ID Exterior Shade Type SHGC H t Wd Len... H t LExt . RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 : R' 19 Bug Screen 0.76 ' 20 Bug Screen 0.76 `" d 21 Bug Screen 0.76 r "' 22 None 1.00 ,. Y 23 Bug Screen. 0.76 10.0 24.0 , - 4.0 0.1 4.0 4.0 " 24 Bug Screen _ 0.76 9.0 - 4.0 4.0 0.1 4.0 4.0 25 Bug Screen 0.76 10.0 8.0 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 10.0 24.0 20.0 0.1 20.0. 10.0 27 Brg Screen - 0.76 10.0 -,8.0 10.0 0.1 10.0. 10.0 ' 28 Bug Screen 0.76 10.01 10.0 -,6-01, 0.1 6.01,4- . 6.0 29 Bug Screen -0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-02-04T10:39:33 ID: Pae 7 of 9 Reg: 2.11-N0015942A-000000000-0000• Registration Date/Time:•,2011/03/29.18 12:13 HERS Provider: CalCERTS, Inc k, Electronically Filed by Tim Scott and Authenticated at CalCERTS.com- 3/29/2011 y Electronically Signed at CalCERTS.com by Yolanda Mendoza (Mendoza Design) 7/15/2011 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5)'. CF -1R Project NameBuilding Kanter Residence Type m Single Family ❑ Addition Alone '❑ Multi Family . ❑ Existing+ Addition/Alteration ate T312412011 OPAQUE SURFACE DETAILS Surface " U- Insulation Joint Appendix Type Area Factor CavitylExterior Frame Interior Frame Azm Tilt Status 4 : Location/Comments Slab 233 0.730 None 0 .180 New 4.4.7-A1 Dining/Media. Bedroom 4 Slab 589 0.730 None s. 0 180 New 4.4.7-A1 Dining/Media. Bedroom 4 Roof 401 0.026 R-38 0 0 New 4.2.1-A9 Dining/Media. Bedroom 4 Wall 136 0.069 R-21 0 90 New 4.3.1-A6 Dinin /Media.Bedroom 4 Wall 177 0.069 R-21 90 90 New 4.3.1-A6 Dinin /Media.Bedroom 4 Slab ' 3291 0.730 None 0 180 New 4.4.7-A1 Dinin /Media.Bedroom 4 Slab 72 0.730 None 0 180 New 4.4.7-A1 Dinin /Media.Bedroom 4 FENESTRATION SURFACE;:DETAILS ID Type I Area ��.- U -Facto: - SHGC Azm Status Glazin Type Location/Comments 33 Window 48.0 0.250 1 NFRC 0. 411 NFRC 270 New Loewen Windows Dining/Media.Bedroom 4 34_". Window 48.0 0.250 'NFRC 0.41 NFRC 270 New Loewen Windows Dining/Media.Bedroom 4 35 Mindowµ'• e'48.0 0.250' NFRC, 0.41 NFRC 270 New Loewen Iindows Dining/Media. Bedroom 4 . •36 Window 11:3 0.250 .NFRC 0.41 NFRC 90 New - Loewen Windows Dining/Media. Bedroom 4 _. 37-, Window „ .._, .1.1;:3 0.250 NFRC .0 41r NFRC _ 90 New , Loewen Windows :. Dining/Media.Bedroom 4 38,'Window; , -. X 48.0 0.250 xNFRC ,,t `x:0.41; ;NFRC, ,, r"qo New'`1 1 Loewen Windows �r w�: A `Dining/Media.8edroom 4 :YT. a '..`YF': =2' r04. .*iAsr, 116 i ;^ h # *,f i!k .�v°r'a t'{. `_":* ^�"�",?'n` �F.. a+r'"i: '�'#F.@ �r 4°t^ - ea r♦ i�f (1) U -Factor Type 1116 A g; Default Table from Standards, NFRC = Labeled Value , 2 SHGC Type: 11-6 B"=Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS' Window Ove hanq Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 r. 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 , ------------- EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-02-04T10:39:33 ID: Page 8 of 9 Reg: 211-N0015942A-000000000-0000 Registration Date/Time: 2011/03/29 18:12:13 HERS Provider: Ca10ERTS, Inc E,jectronically Filed by Tim Scott'and Authenticated at CalCERTS.com -„3/29/2011 "Electronically Signed at�Ca10ERTS.com by Yolanda Mendoza (Mendoza Design) 7/15/2011 I I u CERTIFICATE OF COMPLIANCE: Residential ”(Part 5 of 5) CF -1 R Project Name K2nferResidence Building Type .© Single Family ❑ Addition Alone ❑ Multi Family- ❑ Existing+•Addition/Alteration Date' 3124/2011 BUILDING ZONE INFORMATION . . Floor Area System Name Zone Name New Existing Altered Removed. Volume Year Built HVAC 1 Bedroom 2 & 3 1,094 10,940 HVAC 2. Master Suite 1,615 17,765 ` HVAC 3 Living/Kitchen 71,721 M 22,029 HVAC 4, Dining 606 6,666 Media/HalIlLaundry '' 822 8,631 Bedroom 4 '" , 401 :`' 3,810 • a Totals 6,259 ' 0 0 0 HVAC SYSTEMS .. _� :S stem:.Name Qt : ` :Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status ,Central Furnace 80% AFUE Split Air Conditioner - 14.0 SEER Setback New HVAC 2 `:v cf 1 " t ;Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 3" - 1 Central'Fumace 80%AFUE Sp fit Air Conditioner 14'OSEER Setback+. New r ..,. HVAC 4 � � �.` 1 Cent al`Fumace 80%AFUE Slit+Air,CondiGoner 19 Q SEER Setback ' New �,3��:'�� , ��+�. .�«�.� {' ,�'�,; € ::*�'`a�`,� 4`.-. . `` - � •s'� ..�'"`"' :rte. HVAC DISTRIBUTION,` x��` � „ ,��*� ;.. ._;��':��': „�•� �v ., � �"� :�'� "�,;,��X „ ��. a •„� � t � r, h � ��� - '��Duct,` °Ducts , r....S stem Name .. Heatin r .Coolm ....;Duct Location:' c R Value Tested? Status _ HVAC 1 ...�-i;. Ducted:: Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC.2r °�`:' ry "k Ducted: :� s" Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3< ° _ Ducted' Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 "1"`. Ductedd; Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS:.': S stem Name aty. ' 1 T e i I 4 Distribution Rated 'Input Btuh Tank Cap. al Energy Factor or REr Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White #M -1-100T 1 Large Gas Recirc/Time+Temp 85,000 100 0.80' 0.00%, 0.0 New Bradford White #M -1-75S64 1 Large Gas' Recirc/Time+Temp " 76,0001 75 0.80 0.00% 0.0 - New MULTI -FAMILY WATER HEATING DETAILS. HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length a c `;' S stem Name pipe Len th Pipe Diameter Insul. Thick. �Ot . HP _ Plenum Outside Buried . n '❑. _ ❑ -.. :❑ " EnergyPro 5.1 by EnergySoft User Number.- 6712 Run Code: 2011-02-04710:39:33 ID: Page 9 of 9 Reg: 211-N0015942A-000000000-0000 Registration Date/Time: 2011/03/29.18:12:13 HERS�Provider: Ca10ERTS,, Inc BUILDING ENERGY ANALYSIS REPORT PROJECT: Kanter Residence Lot 272, The Hideaway La Quinta,' Ca 92253 CITY OF LA QUINTA Project Designer: BUILDING & SAFETY DEPT. Mendoza Design APPROVED 79-010 Victoria Drive La Quinta, Ca 92253 FOR CONSTRUCTION (760) 610-2933 DATED% BY +Report Prepared by: Tim Scott r Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760)1200-47 80 < !VFI . �, •• APS 11 2011 - Job 'Number: Date: . r 3/30/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft,.LLC —www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number 6712 Run Code: 2011-03-30T11:15:26 ID: G Y Wq • �J PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kanter Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2011 Project Address Lot 272, The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,317 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes - ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 6,280 Radiant Barrier New Wall Wood Framed R-21 4,877 New Slab Unheated Slab -on -Grade None 6,317 Perim = 573' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (N) 81.9 0.250 0.41 none none Bug Screen New Rear (N) 48.0 0.250 0.41 4.0 4.0/4.0 Bug Screen New Right (E) 191.2 0.250 0.41 none none Bug Screen New Front (S) 74.8 0.250 0.41 none none Bug Screen New Left (lM 264.1 0.250 0.41 none none Bug Screen New Skylight 20.0 0.550 0.39 none none None New Rear (N) 48.0 0.250 0.41 none none Bug Screen New Right (SE) 80.0 0.250 0.41 10.0 none Bug Screen New Front (SIM 90.0 0.250 0.41 none none Bug Screen New Left (NIM 36.0 0.250 0.41 none none Bug Screen New Skylight 17.5 0.550 0.39 none none None New HVAC SYSTEMS City. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Fumace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Large Gas 100 0.80 Recirc/Time+Temp New 1 Large Gas 75 0.80 Recirc/Time+Temp New EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2011-03-30711:15:26 ID: Pae 3 of 35 MW PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Kanter Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2011 Project Address Lot 272, The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,317 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ftp Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (N) 276.0 0.250 0.41 4.0 none Bug Screen New Front (S) 80.0 0.250 0.41 2.0 none Bug Screen New Front (S) 240.0 0.250 0.41 20.0 none Bug. Screen New Left (SK9 80.0 0.250 0.41 10.0 none Bug Screen New Left (SIAO 100.0 0.250 0.41 6.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented , 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-30T11:15:26 ID: Pa e4 of 35 • r, PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name Kanter Residence Building Type m Single Family ❑ Addition Alone I ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. A hot water recirculation systems has been modeled. Verification of type is required. HIGH MASS Design - Verify Thermal Mass: 988.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 & 3 HIGH MASS Design - Verify Thermal Mass: 164.0 ft' Exposed Slab Floor, 3.500" thick at Bedroom 2 & 3 The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,129.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 486.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite The DHW System Bradford White #M-1-75S68N is a non-NAECA large storage gas water heater. Verify DHW details. A hot water recirculation systems has been modeled. Verification of type is required. The HVAC System HVAC 3 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 137.0 ft2 Covered Slab Floor, 3.500" thick at Living/Kitchen HIGH MASS Design - Verify Thermal Mass: 1,584.0 ft2 Exposed Slab Floor, 3.500" thick at Living/Kitchen The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ACA448158C VX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA460/58C VX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA460158CVX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA460/58CVX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-03-30711:15:26 ID: Page 5 of 35 • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) F -1 R Project Name Kanter Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/30/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 606.0 ft2 Exposed Slab Floor, 3.500 "thick at Dining HIGH MASS Design - Verify Thermal Mass: 233.0 ft2 Covered Slab Floor, 3.500" thick at Media/HalIlLaundry HIGH MASS Design - Verify Thermal Mass: 589.0 ft2 Exposed Slab Floor, 3.500" thick at Media/Hall/Laundry HIGH MASS Design - Verify Thermal Mass: 329.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 4 HIGH MASS Design'- Verify Thermal Mass: 72.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 4 The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnergyPro 5.1 by EnemySoft User Number. 6712 Run Code: 2011-03-30T11:15:26 ID: Pae 6 of 35 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Kanter Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1313012011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.08 - 2.20 1.89 Space Cooling 54.64 46.57 8.06 Fans 11.36 13.57 , -2.21 Domestic Hot Water 5.77 5.25. 0.52 Pumps 0.00 0.18 -0.18 Totals 75.85 67.77 8.08 Percent Better Than Standard: 10.7% BUILDING -COMPLIES -HE RS VERIFICATION REQUIRED' Fenestration Building Front Orientation: (S)180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 1,206 485 Fuel Available at Site: Natural Gas L (w) 1,892 480 Raised Floor Area: 0 (N) 1,676 454 Slab on Grade Area: 6,317." (E) 1,793 271 Average Ceiling Height:11.i Roof 6,317 38 Fenestration. Average U -Factor: 0.25 TOTAL: 1,728 Average SHGC: 0.41 Fenestration/CFA Ratio: 27.3% REMARKS The Hideaway Lot 176 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 3/302011 Address 77-085 Michigan Drive Name Tim Scott ' Cit State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility -hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Mendoza Design . Address 79-010 Victoria Drive Name Manual or Yolanda Mandoza .City/State/Zip La Quinta, Ca 92253 Phone (760) 610-2933 Signed License # Date EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-03-30711:15:26 ID: Pae 7 of 35 • Ah CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Kanter Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1313012011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,152 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 2 & 3 Wall 362 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 431 0.069 R-21 90 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 132 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 2 & 3 Wall 367 0.069 R-21 270 90 New 4.3.1-A6 Bedroom 2 & 3 Slab 988 0.730 None 0 180 New 4.4.7-A 1 Bedroom 2 8 3 Slab 164 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 & 3 Roof 1,595 0.026 R-38 270 0 New 4.2.1-A9 Master Suite Wall 232 0.069 R-21 22 90 New 4.3.1-A6 Master Suite Wall 173 0.069 R-21 126 90 New 4.3.1-A6 Master Suite Wall 107 0.069 R-21 180 90 New 4.3.1-A6 Master Suite Wall 111 0.069 R-21 216 90 New 4.3.1-A6 Master Suite Wall 291 0.069 R-21 270 90 New 4.3.1-A6 Master Suite Wall 182 0.069 R-21 306 90 New -4.3. 1-A6 Master Suite Slab 1 1,1291 0.730 1 None 0 180 New 4.4.7-A 1 IMaster Suite Slab 1 4861 0.730 1 None 0 180 New 4.4.7-A1 Master Suite FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 1 15.0 0.2501 NFRC 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 2 Window 21.9 0.250 NFRC 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 3 Window 15.0 0.250 NFRC 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 4 Window 48.0 0.250 NFRC 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 5 Window 15.0 0.250 NFRC 0.41 NFRC 0 New Loewen Windows Bedroom 2 & 3 6 Window 11.3 0.250 NFRC 0.41 NFRC 90 New Loewen Windows Bedroom 2 & 3 7 Window 48.0 0.250 NFRC 0.41 NFRC 90 New Loewen Windows Bedroom 2 & 3 8 Window 48.0 0.250 NFRC 0.41 NFRC 180 New Loewen Windows Bedroom 2 & 3 9 Window 48.0 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Bedroom 2 & 3 10 Skylight 20.0 0.550 NFRC 0.39 NFRC 270 New Skylight Master Suite 11 Window 48.0 0.250 NFRC 0.41 NFRC 22 New Loewen Windows Master Suite 12 Window 80.0 0.250 NFRC 0.41 NFRC 126 New Loewen Windows Master Suite 13 Window 8.8 0.250 NFRC 0.41 NFRC 180 New Loewen Windows Master Suite 14 Window 90.0 0.250 NFRC 0.41 NFRC 216 New Loewen Windows Master Suite 15 Window 11.3 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite 16 Window 24.0 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Ri ht Fin Len Hat LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 8.0 6.0 4.0 0.1 4.0 4.0 0.1 4.0 0 0.1 4.0 0 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 None 1.00 11 Bug Screen 0.76 12 Bug Screen 0.76 10.0 8.0 10.0 0.1 10.0 10.0 13 Bug Screen 0.76 14 Bug Screen 0.76 15 IBug Screen 0.76 16 JBug Screen 0.76 EnergyPrD 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-30T11:15:26 ID: Page 8 of 35 0 4 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) 'CF -1 R Project Name Kanter Residence Building Type m Single Family 13Addition Alone o Multi Family ❑ Existing+ Addition/Alteration Date 1313012011 OPAQUE SURFACE DETAILS � Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,704 0.026 R-38 270 0 New 4.2.1-A9 Living/Kitchen Wall 115 0.069 R-21 0 90 New 4.3.1-A6 LivinglKitchen Wall 421 0.069 R-21 90 90 New 4.3.1-A6 LivinglKitchen Wall 170 0.069 R-21 180 90 New 14.3.1-A6 LivinglKitchen Wall 211 0.069 R-21 234 90 New 4.3.1-A6 Living/Kitchen Slab 137 0.730 None 0 180 New 4.4.7-A1 LivinglKitchen Slab 1,584 0.730 None 0 180 New 4.4.7-A1 . Livin Kitchen Roof 606 0.026 R-38 0 0 New 4.2.1-A9 Dinin /Media.Bedroom 4 Wall 124 0.069 R-21 0 90 New 4.3.1-A6 Dining/Media. Bedroom 4 Wall 223 0.069 R-21 90 90 New .4.3. I -A6 Dining/Media.Bedroom 4 Slab 606 0.730 None 0 180 New 4.4.7-A1 Dining/Media.Bedroom 4 Roof 822 0.026 R-38 0 0 New 4.2.1-A9 Dining/Media. Bedroom 4 Wall 253 0.069 R-21 0 90 New 4.3.1-A6 Dining/Media. Bedroom 4 Wall 97 0.069 R-21 90 90 New 4.3.1-A6 Dining/Media. Bedroom 4 Wall 201 0.069 R-21 180 90 New 4.3.1-A6 IDininglMedia. Bedroom 4 Wall 3611 0.069 R-21 270 90 New 4.3.1-A6 JDiningvMedia.Bedroom 4 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC - Azm Status Glazing Type Location/Comments 17 Window 10.5 0.250 NFRC 0.411 NFRC . 270 New Loewen Windows Master Suite 18 Window 11.3 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite 19 Window .15.0 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Master Suite i 20 Window 6.0 0.250 NFRC 0.41 NFRC 306 New Loewen Windows Master Suite 21 Window 30.0 0.250 NFRC 0.41 NFRC 306 New Loewen Windows Master Suite 22 , Skylight 17.5 0.550 NFRC. 0.39 NFRC 270 New Skylight - Living/Kitchen ' 23 Window 36.0 0.250 NFRC 0.41 NFRC. 0 New Loewen Windows Living/Kitchen 24 Window 240.0 0.250 NFRC 0.41 jNFRC 0 New Loewen Windows Living/Kitchen 25 Window 80.0 0.250 NFRC - 0.41 NFRC '. .: 180 New Loewen Windows Living/Kitchen ` 26 Window 240.0 0.250 NFRC 0.41 NFRC 180 New Loewen Windows Living/Kitchen 27 Window 80.0 0.250 NFRC 0.41 NFRC 234 New Loewen Windows Living/Kitchen 28 Window 100.0 0.250 NFRC 0.41 NFRC 234 New Loewen Windows Living/Kitchen 29 Window 15.0 0.250 NFRC 0.41 NFRC ' 0 New Loewen Windows Dining/Media.Bedroom 4 30 Window 35.0 0.250 NFRC 0.41 NFRC 90 New Loewen Windows Dining/Media.Bedroom 4 31 Window 26.3 0.250 NFRC 0.41 NFRC 90 New Loewen Windows Dining/Media.Bedroom 4 32 Window 18.0 •0.250 NFRC 0.41 NFRC 180 New Loewen Windows Dining/Media.Bedroom 4 (1) Ll -Factor Type: 116-A =Default Table from Standards, NFRC =Labeled Value 2 . SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd' Ove hang Left Fin. Len H t `LExt; RExt Dist Len Right Fin H t Dist Len Hat 17 Bug Screen 0.76 ' 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 . 22 None 1.00. 23 Bug Screen 0.76 • -10.0 24.0 4.0 -'0. 1 4.0 -4.0 24 Bug Screen 0.76 9.0 4.0 4.0 0.1 4.0 . 4.0 25 Bua Screen 0.76 10.0 8.0 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 10.0 24.0 20.0 0.1 20.0 -10.0 s 27 Bug Screen 0.76 10.0 8.0 '10.0 0.1 10.0 10.0 28 Bug Screen 0.76 10.0 10.0 6.0 0.1 6.0 6.0 - 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.761 1t 32 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-03-30711:15:26 ID: Page 9 of 35 • C • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project NameBuilding Kanter Residence Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1313012011 OPAQUE SURFACE DETAILS Surface Ll- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 233 0.730 None 0 180 New 4.4.7-A1 Dining/Media.Bedroom 4 Slab 589 0.730 None 0 180 New 4.4.7-A1 DininglMedia.Bedroom 4 Roof 401 0.026 R-38 0 0 New 4.2.1-A9 Dining/Media. Bedroom 4 Wall 136 0.069 R-21 0 90 New 4.3.1-A6 Dinin /Media.Bedroom 4 Wall 177 0.069 R-21 90 90 New 4.3.1-A6 Dinin /Media.Bedroom 4 Slab 329 0.730 None 0 180 New 4.4.7-A1 Dinin /Media.Bedroom 4 Slab 72 0.730 None 0 180 New 4.4.7-A1 Dinin edia.Bedroom 4 FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Iindow 48.0 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Dining/Media.Bedroom 4 34 Window 48.0 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Dining/Media.Bedroom 4 35 Window 48.0 0.250 NFRC 0.41 NFRC 270 New Loewen Windows Dining/Media.Bedroom 4 36 Window 11.3 0.250 NFRC 0.41 NFRC 90 New Loewen Windows Dining/Media.Bedroom 4 37 Window 11.3 0.250 NFRC 0.41 NFRC 90 New Loewen Windows Dining/Media.Bedroom 4 38 Window 48.0 0.250 NFRC 0.41 NFRC 90 New Loewen Windows Dining/Media.Bedroom 4 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Len H t LExt REA Dist Len Right Fin H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 IBug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-30T11:15:26 /D: Pae 10 of 35 • • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Kanter Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1313012011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Bedroom 2 & 3 1,152 11,520 HVAC 2 Master Suite 1,615 17,765 HVAC 3 Living/Kitchen 1,721 22,029 HVAC 4 Dining 606 6,666 Media/Hall/Laundry 822 8,631 Bedroom 4 401 3,810 Totals 6,317 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 3 1 Central Furnace 80% AFUE Mit Air Conditioner 14.0 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE Split Air Conditioner 114.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.01 JNew WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White #M -1-100T 1 Large Gas RecircJTime+Temp 85,000 100 0.80 0.00% 0.0 New Bradford White #M -1-75S6 1 Large Gas Recirc/Time+Temp 1 76,0001 75 0.80 1 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 _ o i� �o ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-30711:15:26 ID: Pae 11 of 35 ., • � ...�4 F{ a �a. w' - ., } . .. � � s MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1R Project Name Date anter Residence 3/30/2011 • NOTE: Low-rise residential'buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the'documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form.. 150(a): Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. + 150(d): Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for. slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be rotected from physical damage and UV light deterioration. Fire laces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Mason or factory-built fireplaces have a closable metal or lass door coveringthe entire opening of the firebox. §150(e)l B: Masonry or factory-built fireplaces have a combustion outside air, intake, which is at least six square inches in area and is e ui ed with a with a readily accessible, operable,-and tight-fitting damper and or a combustion-air control device. §l50(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water. Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. • - §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage,' includinq that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.' *[tEnerTgyPro 5.1 by EnergySoft User Number. • 6712 RunCode: 2011-03-30711:15:26 ID: Page 12 of 35 ., • � ...�4 F{ a �a. w' - ., } . .. � � s r 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date anter Residence 3/30/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-30T11:15:26 ID: Page 13 of 35 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date anter Residence 3/30/2011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high'efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no , more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131, 134, and 146. • §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-03-30T11:15:26 ID: Page 14 of 35 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name anter Residence Date 3/30/2011 System Name HVAC 1 Floor Area 1,152 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 943 16,879 Return Vented Lighting 0 Return Air Ducts 974 Return Fan 0 Ventilation' 0 0 Supply Fan 0 - Supply Air Ducts 974 TOTAL SYSTEM LOAD 1 18,827 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 71,000 1,519 335 14,587 Total Output Btuh 71,000 Output Btuh/s n 61.6 717 Cooling System 0 Output perSystem 46,500 0 0 0 Total Output Btuh 46,500 1,519 0 Total Output Tons 3.9 717 Total Output Btuh/s ft 40.4 Total Output s ftrron 297.3 16,020 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ACA448/58CVX090 30,579 11,399 71,000 Airflow cfm/s ft 1.39 Airflow cfm/Ton 412.9 Outside Air % 0.0% Total Adjusted System Output 30,579 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 11,399 1 71,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin .Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 111 OF 111 OF Heating Coil - Supply Fan 111 OF 1,600 cfm } k R44M 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 79 / 66 OF 79/66°F 61/60°F 61/60°F Cooling Coil Supply -Fan 61 / 60 OF 1,600 cfm .._.... .............. _._............- 52.6% :.ROOM 78 ! 66 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-30711:15:26 /D: Page 15 of 35 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name, anter Residence Date 3130/2011 System Name HVAC 2 Floor Area 1,615 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 981 21,517 Return Vented Lighting 0 Return Air Ducts 1,242 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1,242 TOTAL SYSTEM LOAD 24,002 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 89,000 1,808 406 17,722 Total Output Btuh 89,000 Output Btuh/s ft 55.1 871 Cooling System 0 Output perSystem 59,000 0 0 0 Total Output Btuh 59,000 1,808 0 Total Output Tons 4.9 871 Total Output Btuh/s ft 36.5 Total Output s ftrron 328.5 19,464 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACA460/58CVX110 46,373 4,983 89,000 Airflow cfm/s ft 1.24 1 89,000 F Jan 1 AM Airflow cfm/Ton 406.8 Outside Air % 0.0% Total Adjusted System Output 46,373 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,983 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan AL 2,000 cfm 70 OF 70 OF 111 OF Heating Coil 111 OF '. ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79164°F 79/64°F 57/56°F w. Outside Air - 0 cfm Supply I Fan Cooling Coil57 156 OF - ............. 2,000 cfm n �A 45.2% ROOM,: 79 ! 64 OF 78 ! 63 OF EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-03-30711:15:26 /D: Page 16 of 35 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY AN Project Name anter Residence Date 3/30/2011 No r System Name HVAC 3 Floor Area 1,721 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,253 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 27,110 1,875 523 22,675 Total Output Btuh 89,000 0 Output Btuh/s ft 51.7 1,565 1,114 Cooling System 0 0 Output perSystem 59,000 0 0 0 0 Total Output Btuh 59,000 0 1,565 30,240 1,875 0 Total Output Tons 4.9 1,114 Total Output Btuh/s ft 34.3 Total Output s ft/Ton 350.0 24,904 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACA460/58CVX110 46,402 5,059 89,000 Airflow cfm/s ft 1.16 Airflow cfm/Ton 406.8 Outside Air % 0.0% Total Adjusted System Output 46,402 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,059 89,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF sem; cQ� Outside Air 0 cfm Supply Fan 2,000 cfm—. 69 OF 69 OF 111 OF � - Heating Coil 111 OF ,. ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak - 112/78°F 79/64°F 79/64°F 57/56°F Outside Air 0 cfm Supply Fan Cooling Coil 58 / 56 OF 2,000 cfm .............................. „ 45.5% ROOM 79/64°F 78!64°F EnergYPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-03-30T11:15:26 /D: Page 17 of 35 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name anter Residence Date 3/30/2011 System Name HVAC 4 Floor Area 1,829 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,409 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 29,449 3,542 467 20,312 Total Output Btuh 89,000 0 Output Btuh/s ft 48.7 1,700 998 Cooling System 01 0 Output per System 59,000 0 0 0 0 Total Output Btuh 59,000 0 3,542 0 Total Output Tons 4.9 1,700 998 Total Output Btuh/s ft 32.3 Total Output s ft/Ton 372.0 32,849 22,309 ,Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACA460/58CVX110 45,191 6,821 89,000 Airflow cfm/s ft 1.09 Airflow cfm/Ton 406.8 Outside Air % 0.0% Total Adjusted System Output 45,191 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK . 6,821 Aug 3 PM 1 89,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 2,000 cfm 70 OF 70 OF 111 OF Heating Coil 111 OF i i' ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79164°F 79/65°F 58/56°F . o Outside Air Ar Supply Fan 0 cfm PP y Cooling Coil58 157 OF 2,000 cfm 47.5% ! "ROOM ' 79!64°F 78/64°F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-30T11:15:26 /D: Page 18 of 35 • • .• V ROOM LOAD SUMMARY Project Name Date Kanter Residence 3/30/2011 System Name Floor Area HVAC 2 1,615 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite Master Suite 1 981 21,517 1,808 981 21,517 1,808 406 17,722 PAGE TOTAL TOTAL* p99j81 21,517 1,808 406 17,72281 21,517 1,808 406 17,722 * Total includes ventilation load for zonal systems. EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-03-30711:15:26 ID: Page 20 of 35 • • ROOM LOAD SUMMARY 29,449 3,542 467 20,312 1,409 29,449 Project Name Kanter Residence 467 20,312 Date 3/30/2011 System Name HVAC 4 Floor Area 1,829 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL WTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Dining/Media.Bedroom 4 Dining 1 246 5,146 1,178 246 5,146 1,178 93 4,060 Media/Hallkaundry 1 801 16,747 1,313 801 16,747 1,313 269 11,707 Bedroom 4 1 362 7,557 1,050 362 7,557 1,050 104 4,546 Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL' 1,4 Ene Pro 5.16 Ene Soft User Number: 6712 RunCode: 2011-03-30711:15:26 ID: Page 22 of 35 09 29,449 3,542 467 20,312 1,409 29,449 3,542 467 20,312 • C ROOM HEATING PEAK LOADS Project Name Kanter Residence Date 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS. Room Name Bedroom 2 & 3 Floor Area 1,152.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area U -Value X 0.0260 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF 44 = Btu/hr R-38 Roof(R.38.2x12.16) 1,152.0 1,318 R-21 Wall (W.21.2x6.16) 1,291.8 X 0.0690 44 = 3,922 Loewen Windows 270.2 X 0.2500 44 = = 2,972 Slab -On -Grade perim = 111.0 X X 0.7300 44 3,565 = = = = X X X X X = = X X = = = X X X = = X = = = = X X X X X X = = = = X X X = = = = X X X X X X = = = = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 1,152 X- Area to another room 10.00 X 0.312 Ceiling Height ACH Page Tota) 160 X 44 AT 1 11.777 = 2,809 TOTAL HOURLY HEAT LOSS FOR ROOM 14,5 7 EnergyPro 5.1 by Energ Soft User Number: 6712 Run Code: 2011-03-30T11:15:26 ID: Page 23 of 35 • • ROOM HEATING PEAK LOADS Project Name Kanter Residence Date 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 1,615.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F Btu/hr 44 = 1,825 44 = 484 44 = 3,326 44 = 3,684 44 = 4,465 = = = = = = = = = = = = = = - = = = = = = = = = = _ Page Total 13,784 / 60 1 X 44 = 3,938 AT R-38 Roof(R.38.2x12.16) 1,595.0 X 0.0260 Skylight 20.0 X X 0.5500 R-21 Wall (W.21.2x6.16) 1,095.6 0.0690 Loewen Windows 334.9 X X 0.2500 Slab -On -Grade perim = 139.0 0.7300 X X X. X X X X X X X X X X X X X X X X X X X X X X X to another room 11.00 X 0.284 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,615 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 17,722 Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-30TH:15:26 ID: Page 24 of 35 L` C ROOM HEATING PEAK LOADS' . Project Name Kanter Residence Date 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Kitchen Floor Area 1, 72 1. 0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X' X X X X X AT °F = = = = = = - = = = - = = = = = = = = = = = = = = _ = = = = - 44 Btu/hr R-38 Roof(R.38.2x 12.16) 1,703.5 X X X 0.0260 44 1,949 Skylight 17.5 0.5500 44 424 R-21 Wall (W.21.2x6.16) 917.0 0.0690 44 2,784 Loewen Windows 776.0 X X X X 0.2500 44 8,536 Slab -On -Grade perim = 149.0 0.7300 44 4,786 X X X X X X X X X X X X X X X X X X X X X X X X through an,interior surface to X 1,721 X Area Ceiling Items shown with an asterisk (') denote. conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 12.80 j( 0.244 Height ACH Page Total /60] X AT 18,478 = 4,197 TOTAL HOURLY HEAT LOSS FOR ROOM 22,675 Ene%yPT 5.1 by Energ Soft User Number- 6712 Run Code: 2011-03-30T11:15:26 /D: Page 25 of 35 LJ F -A 0 ROOM HEATING PEAK LOADS Project Name Kanter Residence Date 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining Floor Area 606.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr R-38 Roof(R.38.2x12.16) 606.0 X 0.0260 44 = 693 R-21 Wall (W.21.2x6.16) 347.0 X 0.0690 44 = 1,053 Slab -On -Grade perim = 26.0 X 0.7300 44 = 835 X = X = = = X X X X X = = = = X X. = X X = = = X X X = = = = X X X X X = = = = = = = X X X X X = = = = = Page Total /60] X 44 AT X X. X X to another room 11.00 X 0.284 Ceiling Height ACH Items shown with an asterisk (") denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 606 X Area 2,582 = 1,478 TOTAL HOURLY HEAT LOSS FOR ROOM 4,060 Energ Pro 5.1 by EnergySoft User Number: 6712. Run Code: 2011-03-30711:15:26 /D: Page 26 of 35 C C ROOM HEATING PEAK LOADS Project Name Kanter Residence Date 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Media/Hall/Laundry Floor Area 822.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 822.0 X 0.0260 911.7 X 0.0690 238.3 X 0.2500 pen.= 105.0 X 0.7300 X X X X X X X X x X X X X X X X X X X X X X X X X X X through an interior surface to another room X 822 X 10.50 X 0.298 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr R-38 Roof(R.38.2x12.16) 44 = 940 R-21 Wall (W.21.2x6.16) 44 = = 2, 768 Loewen Windows 44 2,621 Slab -On -Grade 44 = 3,373 = = = = = = = = = = = = = = = = = = = = = = = = = = = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total /60] X 44 AT 9,702 = 2,005 TOTAL HOURLY HEAT LOSS FOR ROOM 11,707 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-30711:15:26 /D: Page 27 of 35 • r1 L --A • ROOM HEATING PEAK LOADS Project Name Kanter Residence Date 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Floor Area 401.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X x X X X to Ceiling U -Value 0.0260 X 0.0690 X AT *F = = = = = - = = = = = = = = = = = = = = = - = = = = = = = = = 44 Btu/hr R-38 Roof(R.38.2x12.16) 401.0 44 459 R-21 Wall (W.21.2x6.16) 313.4 44 951 Loewen Windows 70.6 0.2500 X 44 777 Slab -On -Grade peri. 43.0 0.7300 X X X X X 44 1,381 X X X X X X X X X X X X X X X X X X X X X X X another room 9.50 X 0.329 Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 401 X Area Page Total / 6o ] X AT 3,568 = 978 TOTAL HOURLY HEAT LOSS FOR ROOM 4,546 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-03-30711:15:26 ID: Page 28 of 35 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name •Kanter Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 & 3 Outdoor Dry Bulb Temperature Floor Area 1,152.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Range: 17-� ODaaue Surfaces R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (N) (E) Date 3/30/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,152.0 0.0260 56.0 362.1 0.0690 23.0 430.7 0.0690 33.0 132.0 0.0690 26.0 367.01 0.0690 33.0 20.2 0.0 20.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration L K L 3a L G 3 3 3a Oriantatinn (N) (N) (N) (N) (N) (E) (E) (S) (►M Shaded Area X X X X X X X X X GLF + + + + + + + + + Unshaded Area GLF 15.0 X 20.2 21.9 X 20.2 15.0 X 20.2 48.0 X 20.2 15.0 X 20.2 11.3 X 44.6 48.0 X 44.6 48.0 X 20.3 48.0 X 44.61 Page Total = = = = = = = = = 0.0 20.2 6.0 20.2 0.0 20.2 0.0 20.2 0.0 20.2 0.0 20.2 0.0 20.2 0.0 20.2 0.0 20.2 112 OF 78 OF 34 OF Btu/hr 1, 677 575 981 836 4, Btu/hr 303 443 303 970 303 503 2,139 975 2,139 8,078 Internal Gain Btu/hr- Occupants tu/hrOccu ants 4.0 Occupants X 230 Btuh/occ. 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 63.04 X 34 = 1,975 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,879 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4.771 X 0.87 X 63.04 X 0.00276 = 719 Air Sensible CFM ELA AW 0 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM _ RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date •Kanter Residence 1 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,615.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature _ 78 OF Outdoor Daily Range: 34 OF G ODaaue Surfaces R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation Area X X X X X X . X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,595.01 0.0260 56.0 232.0 0.0690 25.9 173.0 0.0690 31.4 106.7 0.0690 26.0 111.0 0.0690 30.0 290.9 0.0690 33.0 182.0 0.0690 30.8 0.0 20.2 24.0 44.6 0.0 20.2 Page Total L Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Skylight 3 4 P J G 7 O G (tM (N) (SE) (S) (SIM (►M (►M (tM mg 0.0 0.0 X X X X X X X X X 25.9 + + + + + + + + + 20.0 X X X X X X X X X 78.7 = = = = = = = = = 20.2 48.0 26.7 80.0 20.2 0.0 30.3 0.0 20.2 8.8 20.3 0.0 20.2 90.0 27.8 0.0 20.2 11.3 44.6 0.0 20.2 24.0 44.6 0.0 20.2 10.5 44.6 0.0 20.2 1 11.3 44.6 Page Total Btu/hr 2,322 415 375 191 230 662 387 Btu/hr 1,575 1,280 1,617 179 2,501 503 1,069 468 503 • TOTAL HOURLY LATENT HEAT GAIN Fd Internal Gain. Btu /hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X11 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 88.37 X 34 ._ 2,769 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,517 Latent Gain Btu/hr Occupants 4.0 ,Occupants X 200 - Btuh/occ. _ 800 Infiltration: 4,771 X 0.87 X 88.37 X 0.00276 _ 1,008 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN Fd • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY. Project Name Date Kanter Residence 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS . Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 615.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X _ X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr L 0.0 X 20.2 + 15.0 X 44.6 = 668 N (NIM 0.0 X 20.2 + 6.0 X 35.6 = 214 M (NIM 0.0 X 20.2 + 30.0 X 35.6 = 1,069 X + X = X + X = X + X - X + X = X + X = X 1 +1 X = Page Total 1,951 Internal Gain Btu/hr— tu/hrOccu ants Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 x 0.87 X 88.37 X 34 = 2,769 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,517 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 BtUh/OCC. = 800 Infiltration: 4,771 X 0.87 X 88.37. X 0.00276 _ 1,008 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,808 EnemvPro 5.1 by Enem ySoft User Number: 6712 Run Code: 2011-03-30711:15:26 /D: Pa a 31 of 35 CJ RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kanter Residence 1 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 72 1. 0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Tem erature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (149 1,703.5 X 0.0260 X 56.0 = 2,480 R-21 Wall (W.21.2x6.16) (N) 115.0 X 0.0690 X 23.0 = 183 R-21 Wall (W.21.2x6.16) (E) 421.0 X 0.0690 X 33.0 = 959 R-21 Wall (W.21.2x6.16) (S) 170.0 X 0.0690 X 26.0 = 305 R-21 Wall (W.21.2x6.16) (SIAL 211.0 X 0.0690 X 31.4 = 457 X X = X X = X X = X X - Page Total 4,384 Items shown with an asterisk (') denote'conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (W) 0.0 X 25.9 + 17.5 X 78.7 = 1,378 1 (N). 0.0 X 20.2 + 36.0 X 20.2 = 728 2 (N) 0.0 X 20.2 + 240.0 X 20.2 = 4,851 H (S) 67.7 X 20.2 +. 12.3 X 20.3 = 1,618 2 (S) 240.0 X 20.2 + 0.0 X 20.3 = 4,851 6 (SIM 80.0 X 20.2 + 0.0 X 30.3 = 1,617 5 (s 149 81.1 X 20.2 + 18.9 X 30.3 = 2,212 X + X = X. + X = Page Total 1 17,256 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit .X 1,600 Btu Infiltration: 1.064 X 0.87 X 94.17 X. 34 = 2,951 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,110 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. _ 800 Infiltration: 4,771 X 0.87 X 94.17 X 0.00276 = 1,075 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,875 EnemyPro 5. 1 by EnemySoft User Number 6712 Run Code: 2011-03-30T11:15:26 ID: Page 32 of 35 C� C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kanter Residence 1 3/30/2011 ROOM INFORMATION DESIGN. CONDITIONS Room Name Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 606.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 780F1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (N) 606.0 X 0.0260 X 56.0 = 882 R-21 Wall (W.21.2x6.16) (N) 124.0 X 0.0690 X 23.0 = 197 R-21 Wall (W.21.2x6.16) (E) 223.0 X 0.0690 X 33.0 = 508 X X = X X _ X X = X X = X X = X J X I I= Page Total 1,587 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr X + X = X + X = X + X = X + X = X + X _ X + X = X + X = X + X = X + X = Page Total 0 Internal Gain Btu/hr— tu/hrOccu ants Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 )( 0.87 X 33.16 X 34 = 1,039 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,146 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 33.16 X 0.00276 = 378 Air Sensible CFM . ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,178 Ene Pro 5.1 b Ene Soft User Number: 6712 Run Code: 2011-03-30T11:15:26 ID: Pa a 33 of 35 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kanter Residence 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Media/HalULaundry Outdoor Dry Bulb Temperature 112 OF Floor Area 822.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (N) 822.0 X 0.0260 X 56.0 = 1,197 R-21 Wall (W.21.2x6.16) (N) 253.0 X 0.0690 X 23.0 = 402 R-21 Wall (W.21.2x6.16) (E) 96.7 X 0.0690 X 33.0 = 220 R-21 Wall (W.21.2x6.16) (S) 201.0 X 0.0690 X 26.0 = 361 R-21 Wall (W.21.2x6.16) (W1 361.0 X 0.0690 X 33.0 = 822 X X = X X = X X = X X = Page Total 3,001 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr L (N) 0.0 X 20.2 + 15.0 X 20.2 = 303 E (E) 0.0 X 20.2 + 35.0 X 44.6 = 1,559 D (E) 0.0 X 20.2 + 26.3 X 44.6 = 1,172 C (S) 0.0 X 20.2 + 18.0 X 20.3 = 366 A (lN) 0.0 X 20.2 + 48.0 X 44.6 = 2,139 A (tM 0.0 X 20.2 + 48.0 X 44.6 = 2,139 3a 0.0 X 20.2 + 48.0 X 44.6 = 2,139 X + X = X +1 X = Page Total 9,816 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 44.98 X 34 = 1,409 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,747 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 44.98 X 0.00276 = 513 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,313 Ene Pro 5.1 by Ene Soft User Number: 6712 Run Code: 2011-03-30711:15:26 ID: Page 34 of 35 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Kanter Residence 3/30/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Outdoor Dry Bulb Temperature 1120 Floor Area 401.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (N) 401.0 X 0.0260 X 56.0 = 584 R-21 Wall (W.21.2x6.16) (N) 136.0 X 0.0690 X 23.0 = 216 R-21 Wall (W.21.2x6.16) (E) 177.4 X 0.0690 X 33.0 = 404 X X = X X = X X = X X = X X = X X = Page Total 1,204 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr G (E) 0.0 X 20.2 + 11.3 X 44.6 = 503 G (E) 0.0 X 20.2 + 11.3 X 44.6 = 503 3a (E) 0.0 X 20.2 + 48.0 X 44.6 = 2,139_ X + X = X + X = X + X = X + X = X + X = X +1 X = Page Total 1 3,146 Internal Gain Btu/hr- tu/hr Occupants Occu ants 4.0 Occupants X 230 Btuh/occ. = E920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 21.94 X 34 = 687 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,557 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 21.94 X 0.00276 = 250 Air Sensible CFM 'ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,050 EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-03-30711:15:26 /D: Page 35 of 35 Sladden Engineering 77-725 Enfield Lane, Suite 100, Palm Desert -CA 922.11 (760) 772-3893 Fax (760) 772-3895 6782 Stanton Avenue. Suite A. Buena Park. CA 90621 (714j 523-0952 Fax (714) 523-1369 450 I.gm Avenuc..13caumont. CA 92223 (951) 845-7743 Fax (951) 845-8863' 800 F. Florida Avenue. Hemet, CA 92543 (951) 766-8777 Fax (95 1) 766-8778 December 27, 2010 k 4,rXte1( Re5l*ncz Project No. 544-10220 10-12-300 Fedderly & Associates \ 38747 Nopales Road Palm Desert, California 92211 Project: Proposed Custom Residence APR 1 2 2011 Lot 272 The Hideaway La Quinta, California Subject: Geotechnical Update Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESS) dated April 11, 2001; File No. 08199-01, Report No. 04-04-718. Report of Testing and Observation Durblg Rough Grading prepared by ESS dated August 28, 2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and. Observation During Rough Grading prepared by Sladden Engineering dated October 12, 2003; Project No. 544-2199 Report No.•03-10-647 As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence. The project site is located Lot 272 within the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and .fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were reconfigured. The most recent site grading is summarized in the referenced Report of Testing and Observations During [tough Grading prepared by Sladden Engineering along with the compaction test results. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report prepared by Madden Engineering remain applicable for the design and construction of the proposed residential structure foundations. - December 27, 2010 -2- Project No. 544-10220 10-12-300 Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building falls within the previously assumed building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 1.2 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and; isolated, pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf., respectively. Allowable increases of 300 psf for each additional 1, foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. . The maximum allowable bearing pressure should, be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 2007 California Building Code (CBC). classification criteria. Slab thickness and reinforcement should be determined by the structural engineer, we recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10 -mi{, Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is Si), generally described as stiff soil. The following presents additional coefficients and factors relevant to seismic mitigation for new construction based upon the 2007 California Building Code (CBC). Sladden Engineering December 27, 2010 -3- Project No. 544-10220 r 10-12-300 The seismic design.category for a structure may be determined in accordance with Section 1613 of the 2006 IBC or ASCE7. According to the 2006 IBC, Site Class D may be used to estimate design seismic loading for .the proposed 'structures. The period of the structures should be less than 1� second. This assumption should be verified by the project structural engineer. 'The 2007 CBC Seismic Design Parameters are summarized on the following page. Occupancy Category (Table 16045): ll Site Class ('fable 1613.5.0: D Ss (Figure 161.3.5(3)):1.50g S1 (Figure 1613.5(4)): 0.60g ` Fa (Table .16135.3(1)): 1.0 Fv ('fable 1613.5.3(2)):1.5 Sms (Equation 16-37 RFa X Ssl): 1.508 z Sint (Equation 1.6-38 (Fv X S11): 0.908 SDS (Equation 16-39 12/3 X Sms)): 1.00g SDI (Equation 16-40 12.13 X Sm 11): 0.60g Seismic Design Category based on SDS (Table 1613.5.6(1)): D ... Seismic Design Category based on SDI (Table 161:3.5.6(2)): D. If you have questions regarding this letter or the referenced reports, please contact the undersigned. ' Respectfully submitted; SLADDEN ENGINEERING . RROFESS/pya . Brett L. Anderson) NaC45389 s Principal Engineer x.930 012 J>j CMl Q SER/gl ��F CALIF�Qa\ Copies; 4/Fedderly & Associates Sladden Engineering