Loading...
10-1420 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 10-00001420 Property Address: 80325 VIA PESSARO APN: 777-180-012- - - Application description: DWELLING - SINGLE FAMILY Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 653280 T-v4t 4 4.0" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: VILLANUEVA FAMILY TRUST 3807 42ND AVE NE DETACHED SEATTLE, WA 98105 Applicant: Architect or Engineer: GLZo� 1s�,✓A1 y dYIA z Marra LICENSED CONTRACTOR'SOEYLARATION ' I hereby affirm under penalty of perjury that I am licensed, under provisions of Chapter 9 (commencing with Secticin 7000) of Division 3 of the Business and Professionals Code, ar;d Iny License is in full force and effect. icenseClass: ES �h /% ,License No. 8356 1 v Daieb - "Contractor: OWNER -BUILDER DECLARATION . . I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code:, Any city. or county that requires a perreit to construct,'alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the all exemption. Any violation of Secti6n.7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The . Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the ' improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or ' improve for the purpose of sale.). - (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec: 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Contractor: ENGSTROM CONSTR MANAGEMENT 77455 EVENING STAR INDIAN WELLS, CA 92210. (760)668-3961 Lic. No.: 835648 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 __ Date.: ti 4D 1111 D � ' TO! 0 62G11 1�4 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code,_tDr the performance of the work for which this permit is issued. My workers' compensation insu nce carrier and policy number are: - - Carrier STATE FIIND Policy Number 2380010648 I certify that, in the performance of the work foQ which tpermit is issued, I shall not employ any — l s � n .r person in any ma ner so as to become subject to the orkers' compensation laws of California, and agree that, i(J should become subjectlto�the w,or ers' com nation provisions of Section Z,�I370�he Lab ode, I shall forthwith comply wi(I those vi 3ns� /y t� Dater Applicant L.N`�–• f/� �!_ -. `�� –A" A WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to caricellation. I certify that I have read this application and state that the above information is correct. (,agree to comply with all city and county ordinances and state laws relating to building construction, and hereby'authorize.representatives of this county to I��ntee ujj��on the above-mentioned property fo�n1spection purposes. `% J e ate:��/Signature (Applicant or Agent): U Application Number . . . . . 10-00001420 LQPEPMIT Structure Information Construction'Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . .". . DWELLG/LODGING/LONG <=10 Other struct info . . . . . CODE EDITION, 2007/08 ENERGY # BEDROOMS 6.00 FIRE SPRINKLERS NO GARAGE SQ FTG 2609.00 PATIO SQ FTG 676.00 NUMBER OF UNITS 1.00 IST FLOOR SQUARE FOOTAGE 6443.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 898.00 Permit BUILDING PERMIT Additional desc . Permit Fee 2501.50 Plan Check Fee 1625.98 Issue Date . . . . Valuation . . . . 653,280 Expiration Date 11/28/11 Qty Unit Charge Per Extension BASE FEE 2039.50 154.00 3.0000 THOU BLDG 500,001-1,000,000 462.00 " Permit ELEC-NEW RESIDENTIAL Additional desc .. Permit Fee . . '. 339.12 Plan Check Fee 84.78 . Issue.Date" Valuation 0 ' Expiration Date 11/28/11 Qty Unit Charge 'Per Extension, BASE FEE 15.00 7341.00, .0350 ELEC NEW RES - 1 OR 2 FAMILY 256,94 2609.00 .0200 ELEC GARAGE OR.NON-.RESIDENTIAL 52.18 1.00 15.0000 EA ELEC TEMPORARY POWER POLE — 15.00 Permit GRADING PERMIT INV FEE Additional desc . Permit Fee 30.00 ..Plan Check Fee .00 Issue Date . . . Valuation 0 Expiration Date 11/28/11 Qty Unit Charge Per Extension -------------------------------------------------------------------------- BASE "FEE 30.00 Permit . . . . MECHANICAL LQPEPMIT Application Number . . . . . 10-00001420 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 278.50 Plan Check Fee 69.63 Issue Date . . . . Valuation 0 Expiration Date 11/28/11 Qty Unit Charge Per Extension BASE FEE 15:00 6.00 9.0000 EA MECH FURNACE <=100K 54.00 6.00. 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 99.00 16.00 6.5000 EA MECH VENT FAN 104.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . PLUMBING Additional.desc . Permit Fee. .298.50 Plan Check Fee 74.63 Issue Date . . . . Valuation . . . . 0 Expiration Date.. 11/28/11 Qty Unit Charge Per Extension BASE FEE 15.00 30.00 6.0000. EA PLB'FIXTURE 180.00 1.00 15:0000 EA PLB BUILDING SEWER 15.00 6.00. 6.0000 EA PLB ROOF DRAIN 36.00 2.00 7.5000 EA. PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 14.00 7500; EA-' PLB GAS PIPE >=5 10.50 1.00 15.0000 EA - PLB GAS METER 15.00 --- ------------- ------------------ --------------------------------- -----Special Notes and Comments- GRADING WITHOUT A PERMIT CONFIRMED WITH INSPECTOR S. TRAXEL ON 6/01/2011. INVESTIGATIVE FEE ASSESSED. PER CBC APPENDIX CHAPTER 1 SECTION 108.4 FOR GRADING. June 1, 2011 12:00:26 PM bhanada. 7341 SF 2 STORY.SFD. (LIVING 1ST = 6443 SF. LIVING 2ND = 898 SF) GARAGE = 2609 SF. PATIO,= 676 SF..R-3 OCCUPANCY TYPE; V -B CONSTRUCTION. 2007 /08 CODES. 2008 DIF. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, BBQIS and DRIVEWAY APPROACH** ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 1133.20 BLDG STDS ADMIN (SB1473) 27.00 LQPERAIIT LQPEPA11T Application Number . . . . . 10-00001420 ---------------------------------------------------------------------------- Other Fees . . . . DIF COMMUNITY CENTERS -RES 74.00 DIF.CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 162.60 DIF'FIRE PROTECTION -RES 140.00 DIF LIBRARIES - RES 355.00 MULTI -SPECIES (MSHCP) FEE 1284.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 65.33 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due Permit Fee Total, 3447.62 00 00 3447.62 Plan Check Total' 1855.02 .1000.00 .00 855.02 Other Fee Total 7147.13. .00 00 7147.13 Grand Total 12449.77, 1000.00 .00 11449.77 LQPEPA11T PC I �' - I zor a'eo ���E Ay P.O. BOX 1504 �" � 2 2010 78-495 CALLE TAMPICO APPLICAT N ONLY Building Address A LA QUINTA, CALIFORNIA 92253 CITYLAQUINTA Owner'--� F-IN—fINN E_DEP_T GljIA 4 X111 BUILDING: TYPE CONST OCC. GR_P 1 _ Mailing I T? Address Seo -7 44�w/� W4± -5-P. A.Number CJ Le 1"P7,6/05 P G 05 'CI• Legal Description !J Project Description �1 Z- Tel. State Lic. City & Classif. I Lic. # D„y,., esigner to 773- Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Sq. Ft.No. may. No. Dw. Size :Z?, Z/ Stories l/ Units INe!Y Add ❑ Alter ❑ Repair ❑ Demolition ❑ IEstimated Valuation ODo. 04 D J _PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Driveway Enc. Infrastructure TOTAL REMARKS AMOUNT ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated Validation: YELLOW = APPLICANT PINK = FINANCE 0 O 0 V P.O. BOX 1 504 - BUILDING & SAFETY DEPARTMENT c F` OF T19 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, "CALIFORNIA 92253 FAX (760) 777-7011 September 18, 2012. COPY US Post Office : 79-125 Corporate Center Drive La Quinta, Ca 92253 Postmaster: - Please be advised of an address change for the following structure. The structure formerly addressed as 53-263 Via Strada, APN: 777-180-012, is now addressed as: 80-325 Via Pessaro. The orientation of the single family residence located at this site requires it to have a Via'Pessaro address Please note this change and contact me,directly at (760) 777-7012 if I may be of further assistance. Sincerely, ,.., Kay Hensel Counter Technician 4 Coachella Valle Unified School District Valley This Box For District Use Only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760) 398-5909 — Fax (760) 398-1224 AREA: AMOUNT LEVELONEAMOUNT: LEVELTWOAMOUNT: MITIGATION AMOUNT: COMWIND. AMOUNT: DATE: - ' - RECEIPT: CHECK N: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: !Hid eT a— Date: June 2, 2011 Owner's Name: Villanueva Family Trust, Phone No. 760-668-3961 Project Address: 80-325 Via Pessaro, LaQuinta, CA Project Description: Single Family Dwelling APN: 777-180-012. Tract #: Lot #'s: Type of Development: Residential : XX Commercial Industrial Total Square Feet of Building Area: 7340 sq. ft. Certification of Applicant/Owners- The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of th er/de eloper. Dated: June 2, 2011 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project: Agreement Existing .. , Not Subject to Fee 17620 65995' Approval Prior: to 1/1/87 Requirement • Note: .. , Number of Sq:Ft. 7340 Amount per Sq.Ft. $2.97 Amount Collected $21799.80 Building Permit Application Completed: Yes/N6 By: Jamie T. Brown, Asst. Supt., Business Services c . 140tCertificate issued by: Laurie Howard, Secretary Signature: _, NOTICE OF 96 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1;.1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof; commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. .As in. the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. i%1 V:c/mydoes/dev lecs, certi l icatc o f compliance 11/2010 HID-EAWAY Owners Associ, i0i, June 1, 2011 _ Mr. and Mrs. Bob Villanueva 3807 42nd Avenue N.E. Seattle, WA 981.05 RF: Villanueva Preliininary/ Final Design Review Lot 246 at 8a-�5 VIA PdS5140 Dear Mr. and Mrs. Villanueva: The Hideaway Design Review Committee received your ' eat Lot Final Working on Via P sawing submittal package from. Gordon Stein for'your proposed residence s The project is apptvved to start construction subject to the following comments being addressed prior to your request for review of forms, and must, be. approved prior to pouring any concrete forms. 1. Construction of the pool may not begirt until the revised plan is submitted and approved by the committee. The raised planters at the infinity edge and. the pool are shown a high which is tion permitted.. Eighteen inches is the allowable maximum. Please revise the plan accordingly, (including the grading plan). Once this item has been approved the pool construction may begin as well. 2. The window/sliding glass .door material 'and finish is called out on the elevations; however, the window/door Schedule notes that the builder will furnish samples of. window materials and finish when the manufacturer is selected. Material and finishes must be submitted for approval. 3. The side yard wall lights are shown. above the height of the adjacent yard wall, however, the guidelines require the lights to be at the same height as the wall. Please modify appropriately. 4. There were no specifications provided for the wall mounted lights. Please.provide prior to installation. 5. The material se balcony over the entry pecifications and details were not provided for th doors. This information is required. 6. There are several. chimneys that are shown exceeding the maximum. height of 28' allowed per the guidelines. However, the 28' line is called out from the finished slab rather than approved pad, as required. A change in .this note should bring, the chimneys into compliaiice. 7. The gable end wall detail is not supplied as'far as -recesses, material in. the center, Etc. Please provide detail and clarify on the plans.' 8. _ The quantity of exterior lights across the golf course` elevation is in excess of the `spirit.' of the guidelines. T]iere are a total of 3? Own 1 ghb and 12 Wall 5GOnCC-S (JJ 10lail proposed at the rear elevation. Even ata low wattage, the committee is not in favor of . approving the proposal as submitted. Please reduce the nunaberbof f oemIrutte may also submit an actual sample of the. fixture for further consideration y. Q. LED lighting requirements are currently be.i ng reviewed by the Board. of Directors. Light color. and intensity must match the current lighting requirements listed in the guidelines. And any additional information. or changes to the guidelines that may come. from. the Board with regard to LED lighting while this home is under construction, will be sent to your contractor for compliance in the field. 10. Gerry Tarsitano after thhas reviewed the proposed grading at the rear property lin Since this was approved, once .com.pleted, the area must be restored to its prior condition e completion of construction: The Hideaway Golf Club will invoice you separately for the, $1500 .Encroachment Fee • and their cost to change the . irrigation from their system to yours. for 11. It is the understanding of the coxnm.ittee that the. Vaxiance� ddit nal°nform,atioasa. informational purposes only. If this is not correct, please su 12. We have received: your -$1500 Construction Deposit. 13. The Pre -construction meetiztg was held May 18", however, we have not received a copy of the Building Permit as of the date of this letter. The association requests a copy of this prior to the start o any work on the lot. In addition, at the .request of Glenn Engstrom, the irrigation was changed to, allow the hedge to remain in tack across the front of Via Pessaro during construction. The cost to.lower the irrigation line below the driveway was $190.88 and will be deducted from your deposit unless you would like be invoiced separately for this item. , As a standard note, any deviation from the Design Guidelines crust be submitted with a request for Variance. If a design element is not pxescCE3dit will bVariance the design team's ae responsthe ibility to inadvertently overlooks it during the review pro make modifications at a later date if requested by the Design Review Committee. We look forward to receiving your revised Final drawings, .building permit and to working with you through the construction phase, Please contact Roxi. Bardwell at rbardwel a�drminternet.con� stions or .requests, or 760-393-5211 with any que Sincerely,, Hideaway Design Review Committee Bin # �c City of La uin l G Building h' u Safe Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Wing Permit Application and Tracking Sheet Permit #n o `li( f'4 Project Address: — - Owner's Name: 1 A. P. Number: Address: Legal Descriptio : City, ST, Zip: Contractor:T{, ;.:.�,s.::>,:«w �� : �>,•..�::,,,.: 6 i � elephone: Address: _PF9jeElpescription: City, ST,'Zip: Telephone: ?>`?u: 3;> State Lic. # : City Lie. #.: Arch., Engr., Designer: Address: 1%&4D = ell' QOl( City, ST, Zip: denet Telephone:w\C: ;s,<'\r• Construction Type: Occupancy: ;. State Lic. #: ti: r: , % x. i... �' Project type (circle one): New Add'n Alter Repair Demo ii:'... .ci�v�i... Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted + 2� Item Amount Structural Cities. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance • ' Tide 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2'' Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person �►; (Q )umbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for correction ue Developer Impact Fee Planning Approval Called Contact Person a 0 A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees ��ZZ tust. -2 ;0A0x:. aAt-L- 7 - al! - 7 � Dr,e✓ Is z f Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon Stein (Design Mind Studio) 5/18/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011 Project Address Lot 246 Hideaway Via Pessaro La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,777 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5•of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 7,189 Radiant Barrier ew ., Wall Wood Framed R-21 6,738 LA New ' Slab Unheated Slab -on -Grade None 6,820 Pe 'm = 65 'PIN" SAFETYew Door Opaque Door None 24 1hUILLJ New Floor Wood Framed w/Crawl Space R-19 289 j New STFtU o Y FENESTRATION U_ DAII Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Skylight 24:0 0.550 0.67 none none None New Left (SE). 461 9 0 360 0 26„y none.: none Bug Sereen New . ; : 150.0 0.360 0 26 4 0 no -Bug Screen New Rear(SM.a. r :% .. Right N 3,fi7 1 1. ; ff 0.360 0 26 ,, n .' . none f Bug Scree": ­•r ; New Right (N ' X76 8 b ` . 0:960. :0(26'` 6 0 ..� ;rione Bug Screen Ne`w (NM, Front (NE), 462 61N , 0 36Q 0 26� none_ enone .9 :New 4', ,, fi'IVew Front (NE) 21.3 = ? 0 360 0 26 •, '10 0 `none Bug Screen New Rear (SlM ._ k -_ 102.7 0.360 0.26 none none Bug Screen New Rear (S(M 63.0 0.360 0.26 8.0 none Bug Screen New Rear (SM 479.8 0.360 0.26 10.0 none Bug Screen New Left (SE) 85.3..:, . _ 0.360 0.26 10.0 none Bug Screen New HVAC SYSTEMS . Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.80 All Pipes Ins New EnergyPro 5.1 by Energ Soft User Number: 6712 Run Code: 2011-05-16717:26:21 ID: Page 1 of 11 Reg: 211-N0020129B-000000000-0000 Registration Date/Time: 2011/04/25 13:59:27 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/16/2011 Electronicallv Sioned at CalCERTS.com by Gordon Stein (Design Mind Studio) 5/18/2011 I PERFORMANCE CERTIFICATE: Residential - Part 1 of 5 CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011 Project Address Lot 246 Hideaway Via Pessaro La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7, 777 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION , . U- Exterior Orientation , : Area(ft2) `Factor SHGC' Overhang Sidefins Shades Status µi. t s 0:360 0.26 1 D.0 none Bu Screen . New Reay 30 0;. ,. g Real (SWJ 91 0D 360: 0 26,6 0„y r,none Bug;Sereen New J,,((,,,eeeyyyrrw✓✓.xn � < z v �y* P •... N, ..<.. •�,'sF tt•.hiX.F�!iF-•7.Yx°`ys��-3."''�.7%�� .�, r ,r4, '•FY .�q��y. Y :Ae x� ' .a, : i ANOR UjZ3OR"R F �y "`S`* d`• a .f"T7' k''y 'r .� , �.'y-:.'"^Cv�"` z.. aiT'S*e t. x .�,`',t'.FM!yr�yw�w` 'g+*s.,t,�"'i +Fs—'r"' +T^ {xntcQ,..E:`.s:' HVAC SYSTEMS .. ' Ot . Heating A Min. Eff ' Cooling Min. Eff Thermostat Status 1 Central Furnace 80%'AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location ,. R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ducted Ducted Attic, Ceiling Ins: vented 8.0 New s WATER HEATING ' Ot . Type Gallons Mina Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 ID: Pae 2 of 11 Reg:,211-N0020129B-000000000-0000 Registration Date/Time: 2011/04/25 13:59:27 HERS Provider: Ca10ERTS, Inc ' r Electronically`Filed by:Tim Scott and Authenticated at CalCERTS.com : 5/16/2011 Electronically Signed at CalCERTS.com by Gordon•,Stein (Design Mind Studio) 5/18/2011 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Villanueva Residence - ❑ Multi Family ❑Existing+ Addition/Alteration 5/16/2011 SPECIAL FEATURES INSPECTION CHECKLIST - _ The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I ' - ' The DHW System Bradford -White M-I-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 897.0 ftr Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 272.0 ft Exposed Slab Floor, 3.500" thick at Master Suite HIGH MASS Design -Verify Thermal Mass:, 291.0 ftr Covered Slab Floor, 3.500" thick at Bedroom 2 . HIGH MASS Design - Verify Thermal Mass: ,169.0 ftr Exposed Slab Floor, 3.500" thick at Bedroom 2 « The HVAC System HVAC 2 & 3 must serve only Living Areas.' The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow require ents an'd fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS Design - Verify Thermal -Mass: 225.0 ft Covered Slab Floor, 3.500" thick at Greatroom & Gameroom HIGH MASS Design - Verify Thermal Mass: 1,912.0 ftr Exposed Slab Floor, 3.500" thick at Greatroom & Gameroom The HVAC System HVAC 4 must serveonly Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate`thermostat. `In add�hon the ai t7owreuirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS..Design.,-::Venfy Thermal Mass.,:294.0 ftz Covered Slab Floor, 3.500" thick at Morning & Kitchen HIGH MASSrDesi4fi Venfy Thermal Mass 972'0;ftZ Exposed Sl bi Floo 3:500 thick at Morning & Kdchen k- x..sS"��4w. 3 c HIGH MASS Design -:Verily Thermal'Mass3 930:0 ftz Exposed Slab F/oyor 3;500 a thick at Dmmg & Stairwayxb , a x �2� Xr HERSaREQUIREDVERIFICATION 4` �� f Items m this section require field-testing and/or verification by a certified HERS Rater The inspector rriust receive a t _ �.. coin Ieted.CF=4R fo[m:for: haof the n'ieasuees listed:be.low for_.fin i to.be even: The Cooling* :System Camer24ACA460158CVXO90 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the co rr ect Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. ' The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified cntena; � The Cooling System Carrier 24ACA446158CVX090 includes credit fora 12.0 EER Condenser. A certified HERS rater must field verify the installation f of the correct Condenser. '` - The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. ; The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. `' The Cooling System Carrier 24ACA448158CVX090 includes credit fora 12'0 EER Condenser., A certified HERS rater must field verify the installation of the correct Condenser. i The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria: ' •' - The Cooling System Carrier 24ACA460158C VX090 includes credit fora 12.0 EER Condenser. , A certified HERS rater must field verify the installation- nstallation-of ofthe correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. ,« Ene Pro 5.1 by EnergySoft User Number: 6712, Run Code: 2011-05-16717:26:21 ID: Page 3 of 11 Reg: 211-N0020129B-000000000-0000 Registration Date/Time: 2011/04/25 13:59:27 HERS Provider: CalCERTS, Inc, r V«, Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon Stein (Design Mind Studio) 5/18/2011 PERFORMANCE CERTIFICATE: Residential - (Part 2 of 5) CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 538.0 ftz Covered Slab Floor, 3.500" thick at Beroom 3, & Guest Casita 1 & 2 HIGH MASS Design - Verify Thermal Mass: 320.0 ftz Exposed Slab Floor, 3.500" thick at Beroom 3, & Guest Casita 1 & 2 The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. 77777. Y. y]j?f jryJ HERS REQUIRED VERIFICATIONS 71 J. rM, Items in tf is section, require field testirig and/o ven ication by a certified HERSRater^The inspector, must receive a completed CF -4R form:for each of the measures listed below for final to be given. The Cooling: System Carrier 24ACA460158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation ofthe correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnemyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16717:26:21 ID: Page 4 of 11 Reg: 211-N0020129B-000000000-0000 Registration Date/Time: 2011/04/25 13:59:27 HERS Provider: CalCERTS, Inc Electronically Filed,by Tim Scott and Authenticated at CalCERTS.com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon Stein (Design Mind Studio) 5/18/2011 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Villanueva Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1511612011 ANNUAL ENERGY USE SUMMARY Standard , Proposed - Margin TDV kBtu/ft2- r Space Heating 2.82, 5.24 -2.42 , Space Cooling . 71.97. 52.71 19.25 Fans 14.40 15.33 0.93 Domestic Hot Water 4.42 2.90 1.51 Pumps 0.00 0.00 0.00 Totals 93.60 76.18 17.41 Percent Better Than Standard: 18.6 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 51 deg • Ext. Walls/Roof Wall Area Area Number of Dwelling Units: K 1.00 (NE) 1,959 484 Fuel Available at Site: Natural Gas , (SE) 2,622 547 Raised Floor Area: 289 (SM 2,230 917 Slab on Grade Area:6,820 (Nw) 2,285 387 Average Ceiling Height., V.- 4�. 12.7 '. Roof 7,213 24 3 Fenestration Average U Factor '0.36 TOTAL: 2,359- _Avera e:SHGCw 7::;= 0.26 Fenestration/CFA Ratio: 30.3 REMARKS: y"C 1 4~ �' p! V* i '+�'r.0 r� #� •'.^^`;, -§ '.'I;t, � 1'''''`^'�'...... :"" _ . .«..x«w-� r?'�`'Y'.? � re,.. > ":�i5 t.as: '^�:' `• STATEMENT�'OF COMPLIANCE - • Fists THis certificate ofcomplance the building features and specifications needed to comply with Title 24�,0arts�1`th,e Administrative Regulations and Part 6 the Efficiency Standards of'the�California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author = Company' . Scott Design and Title 24, Inc, - 5/162011 Address 77-085 Michigan Drive Name Tim Scott - +s City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code), Company • Design Mind Studios Address 75175 Merie Drive, Suite 200 • Name Gordon Stein City/State/Zip Palm Desert, Ca 92211 Phone (760)•773-4488 Signed License # Date EnergyPro 5.1 by EnerqySoft User Number: 6712 Run Code: 2011-05-16717:26:21 ID: Page 5 of 11 Reg: 211-N0020129B-000000000-0000 Registration Date/Time: 2011/04/25 13:59:27 HERS Provider: CalCERTS, Inc Electronically.Filed by Tim Scott and Authenticated at CalCERTS.com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon, Stein (Design Mind Studio) 5/18/2011 CERTIFICATE OF COMPLIANCE: Residential ' • ' (Part 4 of 5) CF -1 R Project Name V1118nUeVa Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family . ❑ Existing+ Addition/Alteration Date 5/16/2011 OPAQUE SURFACE DETAILS Surface U- I Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,145 0.026 R-38 0 20 New 4.2.1-A9 Master Suite Wall 459 0.069 R-21 141 90 New 4.3.1-A6 Master Suite Wall 128 0.069 R-21 231 90 New 4.3.1-A6 Master Suite Wall 131 0.069.R-21 321 90 New 4.3.1-A6 Master Suite Slab 897 0.730 None 0 180 New 4.4.7-A1 Master Suite Slab 272 0.730 None 0 180 New 4.4.7-A1 Master Suite Roof 460 0.026 R-38 0 20 New 4.2.1-A9 Bedroom 2 Wall 78 0.069 R-21 321 90 New 4.3.1-A6 Bedroom 2 Wall 146 0.069 R-21 51 + 90 New 4.3.1-A6 Bedroom 2 Wall 206 0.069 R-21 141 90 New 4.3.1-A6 Bedroom 2 Slab 291 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Slab 169 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 2,137 0.026 R-38 0 20 New 4.2.1-A9 Greatroom & Gameroom Wall 318 0.069 R-21 321 90 New • 4.3.1=A6 Greatroom & Gameroom Wall 400 0.069 R-21 '51 90 New 4.3.1-A6 Greatroom & Gameroom Wall 317 0.069 R-21 141 90 New 4.3.1-A6 Greatroom &Gameroom FENESTRATION SURFACE.DETAILS ID Type Area ./'U -Factor: SHGC Azm Status Glazing Type.. Location/Comments 1 Skylight - 24.0 . 0.5W _Default .0.67 Default 0 New - Double Non Metal Clear Master Suite 2.:.. Window...... '20 0 "0 360 `NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. r Master Suite '3 ' Window' 42 7 :0 360 NFRC:. 0.26 NFRC 141 New Dual Non -Metal Tinted. Master Suite 4, Window, 8.0 : • 0.360 NFRC'-- 0.26 NFRC 141 New Dual Non -Metal Tinted. Master Suite 5 Window 20:0 0.360 NERC s ..,_„0 26.. NFRC 141. New Dua/ Non-Metal,Tinted. Master Suite - _. 6 Window, X150.0 0.360 rNFRCY'°„0.26'NFRC,�,",1231 New,; Dual Non IVletal.Tinted;?,+tt�ym Master Suite 7 , Window -•i ` '`155:0 0.360 ,NFRC�S�" ,r`�0.26 'NFRC`„; ;"Y'nY321 New; Dual Non-'Metal:Tmted _ Master Suite.-- ::.c.. . 8 f Window 21.3 740 360• NFRC, ! , 0.26 NFRC:° '32f :New- ? `Dua/NontMetal,Tinted. ' Bedroom 2'""- r - e,, .._ •_ 9 endow;'.: 42?7, 0.360: NFRC ;. 0.26 NFRC,,. >? '321 New,,i`�?r, Dual Non -Metal Tinted._:; �;.�,:;:. Bedioom 2Y„ 10 Window -,0',J 12 8 =;0,360¢.NFRC - "0.26', NFRC x,,321;: New,Dual Non Metal:Tmted., aid Bedroomi2 11 :' Windo*06t C 14,i,,;New, r DuahNon=Metal Torted: 12 Window I. , t':;.'421 7 •'0.360' NFRC,--i. 'r�r P.'26 NFRC i ' 14,1: New;, "t Dual Non -Metal Tinted.=' _tee.' ` Bedroom 2 13 Window 12 0 ,:.0.360 NFRC 0.26` NFRC*" ` 141 New Dual Non -Metal Tinted. "' Bedroom 2 14 Window � 2.8 ?<0.360 :NFRC:::- 6.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 2 15 Window +63:0 :;0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Greatroom & Gameroom 16 Window J 7147 ;°,0.360 NFRC 0.26 NFRC 321 New I Dual Non -Metal Tinted. Greatroom & Gameroom (1) . LI -Factor Type 's 116 A'= Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: - ] 16-13 Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAIL'S - Window Ove hang Left Fin Right Fin ID . Exterior Shade Type SHGC H t _ Wd- Len H t LExt RExt Dist Len Hat Dist Len H t 1 None 1.00 2 Bug Screen 0.76. •' r , 3 Bug Screen 0.76 4 Bug Screen 0.76 5 1Bug Screen 0.76 6 Bug Screen 0.76 10.0 15.0 4.0 0.1 4.0 4.0 7 Bug Screen .0.76 . 8 Bug Screen 0.76 8.0 1.8 6.0 '- "0.1 6.0 6.0 . 9 Bug Screen 0.76 8.0 '5.3 6.0 0.1 6.0 6.0 10 Bug Screen 0.76 8.0 •. 1.8 6.0 0.1 6.0 6.0 11 IBua Screen 0.76 12 Bug Screen 0.76. 13 Bug Screen 0.76 14 Bug Screen 0.76 . 15 Bug Screen 6.76 16. Bug Screen 1 0.761 a EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 ID: Page 6 of 11 Reg: 211-N0020129B-000000000-0000 Registration•Date/Time:,2011/04/25 13:59:27 HERS Provider: Ca10ERTS, Inc .Electronically Filed by Tim Scott and Authenticated at CalCERTS.COm - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon Stein (Design Mind Studio) 5/18/2011 CERTIFICATE OF COMPLIANCE: -Residential (Part 4 of.5) CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑Multi Family ❑Existing+ Addition/Alteration Date 5/16/2011 OPAQUE SURFACE DETAILS Surface U Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status4 Location/Comments Wall 281 0.069 R-21 231 90 New 4.3.1-A6 Greatroom & Gameroom Slab 225 0.730 None 0 180 New 4.4.7-A1 Greatroom & Gameroom Slab 1,912 0.730 None 0 180 New 4.4.7-A1 Greatroom & Gameroom Roof 1,266 0.026 R-38 0 20 New 4.2.1-A9 Morning & Kitchen Wall 4781 0.069 R-21 321 90 New 4.3.1-A6 Morning & Kitchen ' Wall 120 0.069 R-21 51 90 New 4.3.1-A6 Morning & Kitchen Wall 59 0.069 R-21 141 - 90 New 4.3.1-A6 Morning & Kitchen Wall 320 0.069 R-21 231 90 New • ` 4.3.1-A6 Morning & Kitchen Slab 294. 0.730 None 0 180 New 4.4.7-A1 Moming & Kitchen Slab 972 0.730 None 0 180 New' 4.4.7-A 1 Morning & Kitchen Roof 492 0.026 R-38 0 20 New , 4.2.1-A9 Dining & Stairway Wall 440 0.069 R-21 321 90 New 4.3.1-A6 Dining & Stairway Door 24 0.500 None 321 90 New 4.5.1-A4 Dining & Stairway Wall 179. 0.069 R-21 51 90 New 4.3.1-A6 Dining & Stairway Wall 348 0.069 R-21 141 90 New 14.3.1-A6 Dining & Stairway Slab 930 0.730 None -T 0 180 New 4.4.7-A1 Dining & Stairway FENESTRATION SURFACE:DETAILS ID Type Area !XW-Factor.: SHGC Azm Status GlazingType. Location/Comments 17 Window 14.7 ! 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 18_;_ Window 36.0 ;: °0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. • Greatroom & Gameroom 19 . Wlndow :9r 20.0 ' 0.360' NFRC' 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 20 Window .:150:0 • :0.360. NFRC: ;: 0.26 NFRC - 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 21,:.ndow x::14:7 ' 0 360; NFRC �r ;:. 0; 26 NFRC , , ;51 New . , . Dual Non-Metal,Tinted.. Greatroom & Gameroom 22 Wind6w;;�,,t ;- 21 3 0.360 =NFRC �;r' 0,26` ;NFRC' 51 New Dual;Non IVletal;Tmted...'XI `Greatroom & Gameroom 23 Window!°. `1:10.0 0:.360 .NFRCrl i 0.26'NFRC st"-231'1Vew '„ DualNon;Metal;Tinted.'- tr_.,0 Greatroom & Gameroom 24 ;Window._ ] "42.7 ' 0.360, NFRCZ,',,:. 0.26 NFRC :; 231 Newer "Dual-Non,--!Metil•Tintedl; ,al Greatroom & Gameroom., 25' Window f' 12?0 ,x.0:360, NFRC;* ;,. .0:26: NFRC° g -4f,:231 New Dual Non=Metal;Tfnted ' ,gog. Grpatroom-l-& Gameroom 26 Window , ej63.0, 0 36,0,• NFRC 0.2,6,' NFRC ' 23h rNew`„ Dual:Non-Metal,:Tmted.k ;Greatroom"& Gameroom-. 27. Wtndoiw, f„p6l:0•03,6b'NFRC 6.;`6''NFRC 23,11*twiDuak*ho Metal;Tinted ',Gr&5fr6om&'Gameroom 28' Window [T;4;,:3.8 10;360 NFRC *� ' 0.26: NFRC�,� a<" 321 `Dual;Non-Metal. Morning & Kitchen 29 _' Window -_: 21.3 ; ` 0.360 NFRC .' !f'0.26 NFRC" ' ' 321 New Dual Non -Metal Tinted. Morning & Kitchen .130,- Window e :4.7 :-,;0.360 NFRC 0.26 NFRC 321 New ' Dual Non -Metal Tinted. Morning & Kitchen ,:31*;� Window,j --- 21 3 '4"x0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Morning & Kitchen "32 : Window - " 42.7. yi 0 360 MFRC 0.26 NFRC ' 141 New Dual Non -Metal Tinted. Morning & Kitchen (1) LI -Factor Type ,; Default Table from Standards, NFRC =Labeled Value 2 SHGC T e:116 -f3'= Default Table from Standards, NFRC = Labeled Value . EXTERIOR SHADING DETAILS ID Window' Ove hang Left Fin Right Fin Exterior Shade Type SHGC t H t. Wd 'Len H t LExt RExt Dist Len Hat Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen , 0.76. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 8.0 . _. 2:7 10.0 .0.1 10.0 .10.0 23 Bug Screen 0.76 - - r 24 Bug Screen 0.76 " 25 Bug Screen 0.76 26 Bug Screen 0.76 a 10.0 9.0 8.0 0.1 8.0 8.0 27 Bug Screen 0.76 10.0 20.0 .10.0 .0.1 10.0 10.0 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 k 31 JBug Screen 0.76 8.0 2.7. 10.0 0.1 10.0 10.0 . 32 JBug Screen 0.76 8.0 2.7 10.0 0.1 10.01 10.0 EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-05-16T17:26:21 ID.' Pae 7 of 11 Reg: 211-N0020129B-000000000-0000 Registration Date/Time: 2011/04/25.13:59:27 HERS Provider: Ca10ERTS, Inc f- ;' r� til - •.' - � r• - „- � r' - � �- . w F• r Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon Stein (Design Mind Studio) 5/18/2011 N CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status ' 4 Location/Comments Roof 497 0.026 R-38 0 20 New 4.2.1-A9 Bedroom 4 Wall 161 0.069 R-21- 321 90 New 4.3.1-A6 Bedroom 4 Wall 29 0.069 R-21 51 90 New 14.3.1-A6 Bedroom 4 Wall 163 0.069 R-21 141 90 New 4.3.1-A6 Bedroom 4 Wall 241 . 0.069 R-21. 231 90 New 4.3.1-A6 Bedroom 4 Roof 1,192 '0.026 R-38 0 20 New 4.2.1-A9 Bedroom 3, Guest Casita Wall 267 0.069 R-21 321 90 New 4.3.1-A6 Bedroom 3, Guest Casita Wall 601 0.069 R-21 51 ': 90 New 4.3.1-A6 Bedroom 3, Guest Casita Wall 523 0.069 R-21 141 90 New, 4.3.1-A6 Bedroom 3, Guest Casita Wall 343 0.069 R-21 231 90 New 4.3.1-A6 - Bedroom 3, Guest Casita Slab 538 0.730 None 0 180 New 4.4.7-A1 Bedroom 3, Guest Casita Slab 320 0.730 None 0 180 New 4.4.7-A1 Bedroom 3, Guest Casita Floor 289 0.037 R-19 0 180 New 4.4.1-A4 Bedroom 3, Guest Casita FENESTRATION SURFACE DETAILS ID Type Area "`U=Factor:: SHGC2 Azm Status Glazing Type Location/Comments 33 Window 21:3 ' 10:3601 NFRC ' 0.26 NFRC 141 New Dual Non -Metal Tinted. Morning & Kitchen 34 _ Window .: :;, 8.0 ' 0..360 NFRC,, 0.26 NFRC 231 New Dual Non -Metal Tinted. Morning & Kitchen -35 : Wlndow «; n"42.7 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Morning & Kitchen 36 Window-,..'' " .":3010 .-0.360 NFRC:i w 0.26 NFRC -231 New Dual Non -Metal Tinted. Morning & Kitchen 37K Window : _5 0 ti 0.360 NERCO %';_. 0,,26 'NERC x 231 New , Dual Non -Metal Tinted. Morning & Kitchen 38 , WindoW, .� ;;<;11:42.7 0.360 NFRC rrK 0 26'NERC, ` 23.1. `New ^? Dual'Non Metal , tedi r Morning & Kitchen 39 lNindow •'130:0 0.360 NERC <: 0.26 !NFRC�ti; "231Newi Dual'Non;Metal,Tinted4t "f Morning& Kitchen 40 '.lNindow.:: 14..71 `0.360, N RC '?'`:0.26 NFRC� X231 'New ^ ', Dual.NogEMeitaF,Tinted..V, -', Mor 41 Window • 30X0 t,,0:360 NFRC ... 0.26' NFRC° . 321. 'N, eWU Dual. Non-Metah,Tinted 41 Dining &:Stairw_a- # 42 Window r 1 300,:N. RCtt_' %.0.26, NERC., ° '" ,321 PNewl„ g, ,Dual Non-Metal.;Tinted. =` Dining -,&?Stairway 43::,? V1%indowu i1 30 0' „0360 "NFRC1a X0:2`6'`NERC; 5.1 :New Duaf-Non-Metal,Tinied. ' t' 'Qrnrng &:?Stainvay3; 44" Window ;, 430 0 <0;360 NFRC* - X0.26 NFRC i,^ " ,..r?51 New,, w Dual Non -Metal Tinted.' ., �:. Dining & Stairway ` .: ,. 0.26 NFRC ; `' " 141 New Dual Non -Metal Tinted. "45 Window . .,; 21 3 .0.360 NERC - Dining & Stairway Y 46.,. Wiridow fi21:3 1 0.360 NFRG : 0.26 NFRC : 141 New Dual Non -Metal Tinted. Dining & Stairway 47. Window :-" x"14::7 :r0:360 'NFRC 0.26 NFRC 141 New_ • Dual Non -Metal Tinted. Dining & Stairway 48,• Window ;: -10.01k Q.360.NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway (1) Ll -Factor Type " :116 A =: Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: -116-B'= Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS I I I' Window ID Exterior Shade TylSe SHGC H t . Wd - Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 8.0 `2.7 ' 10.0 0.1 '110.0 1 10.0 34 Bug Screen - 0.76 8.0 2.2 10.0 0.1 10.0 40.0 35 Bug Screen ` 0.76 8.0 2.7 10.0 0.1 10.0 10.0 - 36 '.Bug Screen 0.76 8.0 2.2 10.0 0.1 10.0 10.0 37 Bug Screen 0.76 8.0 3.3 10.0 0.1 .10.0 ••.10.0 38 Bug Screen 0.76 8.0 2.7 10.0 0.1 10.0 10.0 39 Bug Screen 0.76 8.0 3.3 10.0 0.1 10.0 10.0 40 Bug Screen 0.76 6.0 -4.0 10.0 0.1 10.0 10.0 41 Bug Screen 0.76 42 Bug Screen 0.76 ' 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 JBug Screen 0.76 EnergyPro 5.1 by Ene Soft User Number: 6712. Run Code: 2011-05-16717:26:21 ID: Page 8 of 11 A Reg: 211-N0020129B-000000000-0000' Registration Date/Time:,2011/04/25 13:59:27 HERS•Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon Stein (Design Mind +Studio) 5/18/2011 I CERTIFICATE OF COMPLIANCE: Residential(Part 4 of 5) CF -1 R Project Name R Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011. OPAQUE SURFACE DETAILS Surface. • U- Insulation Joint Appendix Type Area Factor Cavit . Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments + FENESTRATION SURFACEDETAILS • . ID Type Area SHGC2 Azm Status . Glazing Type Location/Comments 49 Window 42.7 0 360 ;NERC 0.26 NFRC 141 New Dual Non-Metal.Tinted. Dining & Stairway 5,0-,:: Window • :' 10.5. :0 360.:NFRC. 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 51 Window" --+_721.3 0.360 NERC.:' `. 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 52 _ Window ';,21:3. 0:360 NERC: 0.26 NFRC- 141 New Dual Non -Metal Tinted. Dining & Stairway 53;x. Windows :; 21:3. 0.360. NFRC .. 0 2¢ NFRC 141, New Dual N_on-Metal,Tinted., Dining & Stairway . . 54 . Window» ' ;;' 21;3; ' 0.360 °NFRC, * 0 26' 1VFRC, #' z +� 51 ;New „� , t Dug1,W&h Meta"'liTmted '':Bedroom 4 55 r ` 42.`/ 0..360 NFRC x:0.26! NFRC „� 141 New = ":,. Dual Non,M&tahTmted�kUl..:! Bedroom 4 _. Window., '. 56 Window'.;; 8 0 'Q 360 NFRC a' ` 0.26 NFRC , 231. ;New,- � `Dual Non"MetaUiinted.. ; "a;`, Bedroom 4'" 57 Gl!indow,; : 30'0 ; '0 360; NFRC, `i'-. '0:26,. NFRC:A i f J231;: New e . Dua1Non M6tal',Tmted. rsir"',; Bedroom 4 rev 58 Window,:' f60:0; ;03.fiQ. NFRC' t 0.2,6,' NFRC,7 >"'x,321 r'New,;'- ��•-Dual,Non-Metal;Tmted Y"-:; o�V:Bedroom'3,.GuestCasita 1 & 2 59.,,t Window t'r 21 3 . 0,360, NFRC New Dual Non Me`al;T"ted ° a:'Bedroo'm;3,�GuestPCasita l & 2 X0.26" ;NFRC , 32,1x ,, 60'! fridow ,; „ 21 3 1 0:360 NFRC i =0:26, •NFRC _.: ; 32:1 New _ s Dual..:Non=Nletal:Tmted u . e ?ri `Bedroom 3, Guest Casita 1 & 2 61 Window 30 0. ' 0.360 NFRC < ` 0:26' NFRC':' 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 62-,,.. t4findow1-30.0 0.360 'NFRC. 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 63 Ii.. Window ; {*30:0 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 64:, Window-' 17'3 , 0.36P. NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 (1) LI -Factor Type I:16 -A, ='` Default Table from Standards, NFRC = Labeled Value 2 SHGC T e ] 16 B=Default Table from Standards, NFRC = Labeled Value . EXTERIOR SHADING DETAILS' Window .Ove rhang, Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t:. LExt RExt Dist Len H t Dist Len H t • 49 Bug Screen 0.76 50 Bug Screen 0.76 - 51 Bug Screen 0.76 - 52 Bug Screen 0.76 53 Bug Screen 0.76 ' 54 Bug Screen 0.76 55 Bug Screen 0.76 - 56 Bug Screen 0.76 F 57 Bug Screen 0.76 10.0 20.0 10.0 0.1 10.0. 10.0 58 Bug Screen : ` 0.76 59 Bug Screen 0.76 ' • - ` 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 ' 63 Bug Screen 0.76 64 JBug Screen 0.76 ' EnergyPro 5.1 9-Y EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 ID: • Page 9 of 11 1 _ Reg: 211-N0020129B-000000000-0000 :Registration Date/Time:'2011/04/25,13:59:27',. HERS Provider: CalCERTS, Inc 0 r E12ctronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon .'Stein (Design Mind Studio) 5/18/2011 CERTIFICATE OF COMPLIANCE: Residential : , (Part 4 of 5) CF -1 R Project Name • • - Villanueva Residence - Building Type 0 Single Family 0 Addition Alone 0 Multi Family ' 0 Existing+ Addition/Alteration Date 1511612011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments i FENESTRATION SURFACE.DETAILS ID Type Area ./U -Factor.' SHGC2 Azm Status < Glazing Type Location/Comments 65 Window 17.3 _0:360 'NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 66-, Window.., .-;21.3 • 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. - Bedroom 3, Guest Casita 1 & 2 67 Window `Z 30 0 0.360. NFRC: 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 68 Window ;.1'7.3. % 0.360 NFRC... 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 69:'s. Window x::1.7.3 0.360 NFRC ,0 26 NFRC 141 New .m Dual Non -Meta/ Tinted. Bedroom 3, Guest Casita 1 & 2 __ _ _ .x;231. New "Dual Non Metal.Tmted ,; ':Bedroom 3, Guest Casita 1 & 2 70. ,Window, x.300; 0.360 ,NFRC 0 26 ;NFRC„k ° , , 71 Window�� ••' 20;0' 0.360 NFRC �V0.26sNFRC� z ."231 New „,Dua/Non-Metal;Tmted. t ,'Bedroom 3, Guest Casita 1 & 2 72 'Window ;t 42.70360, NFRC? E 0.26 NFRC, :231 New 9 a�`dDuaLNon-.Metal;Tinted. '" Bedroom 3,'GuestCasita ,i & 2 73 Window :: ,50 x:0360 NFRC `s 0.26,NFRC„ ' Rv 231 ;,New !V*>t Dua/Non-Metal Tinted' _ Bedroom 3,.Guest,Casita 1„& 2 74 Window:. ,,,�' /23 3 0 360: NFRC; .:,t 0.26,' NFRC � ,231,Wew"' �Dua1 Non'Metal Tmted.';> �� �}x Bedroom 3, Guest Casita 1-& 2 _ .x 75 s Wndow�+b4 f 42 7 aa0 360. NFRC` X0.26 ,NFRC W" 23L New `. ". Dual Non,Metal:Tinted. ° :i Bedroom,3,,Guest"Casita 1 & 2 76" lMndow ,, m': 213 :,0.360 NFRC <'0.26 NFRC; = ` X231 New iy Dual: Non-Metal:Tmted. ' `= Bedroom 3, Guest Casita 1 & 2 77 Window _ '_ 42 7: 0.360 ` 0:26 NFRC • 231 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 $NaFRC (1) Ll -Factor Type x,116 A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: .116,13'=' Default Table from Standards, NFRC = Labeled Value _ EXTERIOR SHADING DETAILS' Window . Ove hanq Left Fin Ri ht Fin ID Exterior Shade T e SHGC• H t Wd • Len H t LExt RExt Dist Len H t Dist Len H t 65 Bug Screen • 0.76 66 Bug Screen 0.76 ' 67 Bug Screen 0.76 68 Bug Screen 0.76 0 69 Bug Screen .0.76 70 Bug Screen 0.76 71 Bug Screen 0.76 _ 8.0 1.8 6.0 0.1 6.0 6.0 72 Bug Screen 0.76 8.0 .5.3 6.0 0.1 6.0 6.0 ' 73 Bug Screen 0.76 8.0 1.8 6.0 __.0.1 6.0 6.0 74 Bug Screen 0.76 8.01 1.8 6.01 0.1 6.0 6.0 75 Bug Screen 0.76 8.01 5.3 10.0 0.1 10.0 10.0 76 Bug Screen 0.76 8.01 1.8 10.0 0.1 10.0 10.0 77 Bug Screen 0.76 8.0 4.3 10.0: 0.1 10.0 10.0 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-16717:26:21 ID: Pae 10 of 11 Reg: 211-N0020129B-000000000-0000 Registration Date/Time:-2011/.04/25 13:59:27 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/16/2011 Electronically Signed at CalCERTS.com by Gordon Stein (Design Mind'Studio) 5/18/2011 CERTIFICATE OF COMPLIANCE: Residential r (Part 5 of 5) -C -1 R Project Name Villanueva Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family, ❑ Existing+ Addition/Alteration Date 1511612011 BUILDING ZONE INFORMATION Floor Area S stem Name Zone Name' New Existing Altered Removed . Volume Year Built HVAC 1 Master Suite 1,169 14,028 Bedroom 2 460 5,520 HVAC 2 & 3 Greatroom & Gameroom 2,137 27,781 HVAC 4 Morning & Kitchen 1,266 15,192 HVAC 5 Dining & Stairway 930 11,160 Bedroom 4 497 4,970 HVAC 6 Beroom 3, & Guest Casita 1 & 2 1,318 19,770 1 x i Totals 7,777 0 01 0 HVAC SYSTEMS;*= S stem.Name , ° Qt : -. Heatin Type Min. Eff. • CoolingType. Min: Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80 %AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2'&. 3 ` .2 `'. 'Central,Fumace 80% AFUE Split Air Conditioner 14.0 SEER Setback. New HVAC 4 ,;A , 1 Central,;Furnace p 8,0,% AFUE; Split Air, Conditioner ,!-#7,0. SEER, Setback' ::. New Central�Furnace 80%AFUE..S Id, Arr;ConditionerJi .14:0 SEER Setback s New ,. - , c } '*d HVAC 6 ,,:: '" z1, 'Central,Furnace _, ,80/AFUE Splrt Av Conddioner; 19 O SEER SetbackF ''*°wF.� ';_: New . HVAC DISTRIBUTIONW��;rt.:;`°,�'�` DuctAV, U Ducts + :�* �k.-•`.P. K *':'+m.°� ^4 '�u•' rr�.'.aa& kg+' '.•-°Y '•3Y ':- -Vfv� :: Y;' ., - .. S stem NarverHeatm '�>7„ Coolm �' Duct Losationr�' a,'R-Value Tested? . Status HVAC 1 Ducted; ' . Ducted " Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New 'Ducted , Ducted Attic, Ceiling Ins, vented 8.0 ❑ New HVAC 5 " Ducted 8-5'" _ Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 6 Ducted Ducted Attic, Ceiling Ins, vented 8.01 IZI New WATER HEATING SYSTEMS'; r S stem Name - Qty. - Type Distribution Rated Input ` (13t h) r Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White M -1-100T6 2 Large Gas- ` All Pipes Ins ' = 85,000 • 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length .N ¢ T System Name Pipe Length Pipe Diameter Insul. Thick. 7QtyHP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-05-16717:26:21 ID: Pae 11 of 11 ,Reg: 21.1-N0020129B-000000000.0000 Registration Date/Time: 2011/04/25 13:59:27 . - "tib r r y.. *.�' r-�' Y` ,�,,•'•,� -^'' . HERS Provider: CalCERTS, Inc '•. •y, - ' .-.-�. �• ^L �- .. �- ..Fly • . BUILDING, ENERGY ANALYSIS REPORT . PROJECT: .Villanueva Residence Lot 246 Hideaway Via Pessaro La Quinta; CA 92253 Project Designer: Design Mind Studios 75175 Merle Drive, Suite 200 ,Palm -Desert,, Ca 92211 -4760).773-4488 Report 'Prepared by: Tim Scott Scott Design and Title 24, Inc; 77-085 Michigan Drive �. • Palm, Desert, Ca 92211 (760) 200-4780 , �__...._.._.�,.... CITY OF LA QUINTA BUILDING & SAFETY DEPT. I j APPROVED , i FOR CONSTRUCTION Job•Number: it DATE of 20,18— -• o Date: • 5/16/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by'EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16717:26:21 /D: 4,,, .. �� n .. � � • PJ PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1511612011 Date Project Address Lot 246 Hideaway Via Pessaro La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,777 Addition n/a . # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 7,189 Radiant Barrier New Wall Wood Framed R-21 6,738 New Slab Unheated Slab -on -Grade None 6,820 Perim = 652' New Door Opaque Door None 24 New Floor Wood Framed w/Crawl Space R-19 289 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Skylight 24.0 0.550 0.67 none none None New Left (SE) 461.9 0.360 0.26 none none Bug Screen New Rear (SIM 150.0 0.360 0.26 4.0 none Bug Screen New Right (NIM 310.1 0.360 0.26 none none Bug Screen New Right (NlM 76.8 0.360 0.26 6.0 none Bug Screen New Front (NE) 462.6 0.360 0.26 none none Bug Screen New Front (NE) 21.3 0.360 0.26 10.0 none Bug Screen New Rear (SIM 102.7 0.360 0.26 none none Bug Screen New Rear (SlM 63.0 0.360 0.26 8.0 none Bug Screen New Rear (SIM 479.8 0.360 0.26 10.0 none Bug Screen New Left (SE) 85.3 0.360 0.26 10.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.80 All Pipes Ins New EnergyPry 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 /D: Pa e3 of 45 • �J • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone . ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011 Project Address Lot 246 Hideaway Via Pessaro La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,777 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ftp Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (SK9 30.0 0.360 0.26 10.0 none Bug Screen New Rear (SWJ 91.0 0.360 0.26 6.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 ID: Page 4 of 45 • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White M-I-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass: 897.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 272.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 29 1. 0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 169.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 The HVAC System,HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 225.0 ft2 Covered Slab Floor, 3.500" thick at Greatroom & Gameroom HIGH MASS Design - Verify Thermal Mass: 1, 912.0 ft2 Exposed Slab Floor, 3.500" thick at Greatroom & Gameroom The HVAC System HVAC 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 294.0 ft2 Covered Slab Floor, 3.500" thick at Morning & Kitchen HIGH MASS Design - Verify Thermal Mass: 972.0 ft2 Exposed Slab Floor, 3.500" thick at Morning & Kitchen HIGH MASS Design - Verify Thermal Mass: 930.0 ft2 Exposed Slab Floor, 3.500" thick at Dining & Stairway HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ACA460158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24A CA448158C VX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA448158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24ACA460158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro, 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16717:26:21 ID: Page 5 of 45 0 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511612011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA -6 must be met. HIGH MASS Design - Verify Thermal Mass. 538.0 ftZ Covered Slab Floor, 3.500" thick at Beroom 3, & Guest Casita 1 & 2 HIGH MASS Design - Verify Thermal Mass: 320.0 ft' Exposed Slab Floor, 3.500" thick at Beroom 3, & Guest Casita 1 & 2 The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. i HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24ACA460158CVX090 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. i EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-05-16717:26:21 ID: Pae 6 of 45 • . 0 PERFORMANCE CERTIFICATE: Residential' (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Villanueva Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 1511612011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/V- r Space Heating 2.82 5.24 -2.42 Space Cooling 71.97 52.71 19.25 Fans 14.40 15.33 -0.93 Domestic Hot Water 4.42 2.90 1.51 Pumps 0.00 o.00 0.00 Totals 93.60 76.18 17.41 Percent Better Than Standard: 18.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 51 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 1,959 484 Fuel Available at Site: Natural Gas (SE) 2,622 547 Raised Floor Area: 289 (Std 2,230 917 Slab on Grade Area: 6,820 (N K9 2,285 387 Average Ceiling Height: 12.7 Roof 7,213 24 Fenestration Average U -Factor: 0.36 TOTAL: 2,359 Average SHGC: 0.26 Fenestration/CFA Ratio: 30.3 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and comple Documentation Author Company Scott Design and Title 24, Inc, 5/162011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Design Mind Studios • Address 75175 Merle Drive, Suite 200 Name Gordon Stein 441FA 4Signed City/State/Zip Palm Desert, Ca 92211 Phone (760) 773-4488 License # Date EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-05-16717:26:21 ID: Pae 7 of 45 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511612011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavit Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,145 0.026 R-38 0 20 New 4.2.1-A9 Master Suite Wall 459 0.069 R-21 141 90 New 4.3.1-A6 Master Suite Wall 128 0.069 R-21 231 90 New 4.3.1-A6 Master Suite Wall 131 0.069 R-21 321 90 New 4.3.1-A6 Master Suite Slab 897 0.730 None 0 180 New .4.4.7-A 1 Master Suite Slab 2721 0.730 None 0 180 New 4.4.7-A1 Master Suite Roof 4601 0.026 R-38 0 20 New 4.2.1-A9 Bedroom 2 Wall 781 0.069 R-21 321 90 New 4.3.1-A6 Bedroom 2 Wall 146 0.069 R-21 51 90 New 4.3.1-A6 Bedroom 2 Wall 206 0.069 R-21 141 90 New 4.3.1-A6 Bedroom 2 Slab 291 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Slab 169 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 2,137 0.026 R-38 0 20 New 4.2.1-A9 Greatroom & Gameroom Wall 318 0.069 R-21 321 90 New 4.3.1-A6 Greatroom & Gameroom Wall 400 r 0.069 R-21 51 90 New 4.3.1-A6 Greatroom & Gameroom Wall 3171 0.069 R-21 1411 90 New 4.3.1-A6 Greatroom & Gameroom FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Skylight 24.0 0.550 Default 0.67 Default 0 New Double Non Metal Clear Master Suite 2 Window 20.0 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Master Suite 3 Window 42.7 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Master Suite 4 Window 8.0 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Master Suite 5 Window 20.0 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Master Suite 6 Window 150.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Master Suite 7 Window 55.0 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Master Suite 8 Window 21.3 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Bedroom 2 9 Window 42.7 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Bedroom 2 10 Window 12.8 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Bedroom 2 11 Window 12.0 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 2 12 Window 42.7 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 2 13 Window 12.0 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 2 14 Window 12.8 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 2 15 Window 63.0 0.360 NFRC 0.26 NFRC 321 New 1 Dual Non -Metal Tinted. Greatroom & Gameroom 16 Window 14.7 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Greatroom & Gameroom (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt REA Dist Len Right Fin H t Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 10.0 15.0 4.0 0.1 4.0 4.0 7 Bug Screen 0.76 8 Bug Screen 0.76 8.0 1.8 6.0 0.1 6.0 6.0 9 Bua Screen 0.76 8.0 5.3 6.0 0.1 6.0 6.0 10 Bug Screen 0.76 8.0 1.8 6.0 0.1 6.0 6.0 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 IBug Screen 1 0.761 1 EnergyPro, 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16717:26:21 ID: Page 8 of 45 • • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Villanueva Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511612011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 281 0.069 R-21 231 90 New 4.3.1-A6 Greatroom & Gameroom Slab 225 0.730 None 0 180 New 4.4.7-A1 Greatroom & Gameroom Slab 1,912 0.730 None 0 180 New 4.4.7-A1 Greatroom & Gameroom Roof 1,266 0.026 R-38 0 20 New 4.2.1-A9 Morning & Kitchen Wall 478 0.069 R-21 321 90 New 4.3.1-A6 Morning & Kitchen Wall 120 0.069 R-21 51 90 New 4.3.1-A6 Morning & Kitchen Wall 59 0.069 R-21 141 90 New 4.3.1-A6 Morning & Kitchen Wall 320 0.069 R-21 231 90 New 4.3.1-A6 Morning & Kitchen Slab 294 0.730 None 0 180 New 4.4.7-A1 Morning & Kitchen Slab 972 0.730 None 0 180 New 4.4.7-A 1 Morning & Kitchen Roof 492 0.026 R-38 0 20 New 4.2.1-A9 Dining & Stairway Wall 440 0.069 R-21 321 90 New 4.3.1-A6 Dining & Stairway Door 24 0.500 None 321 90 New 4.5.1-A4 Dining & Stairway Wall 179 0.069 R-21 51 90 New 4.3.1-A6 Dining & Stairway Wall 348 0.069 R-21 141 90 New 4.3.1-A6 Dining & Stairway Slab 930 0.730 None 0 180 New 4.4.7-A1 -Dining & Stairway FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 14.7 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 18 Window 36.0 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 19 Window 20.0 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 20 Window 150.0 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 21 Window 14.7 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 22 Window 21.3 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Greatroom & Gameroom 23 Window 10.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Greatroom & Gameroom 24 Window 42.7 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Greatroom & Gameroom 25 Window 12.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Greatroom & Gameroom 26 Window 63.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Greatroom & Gameroom 27 Window 200.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Greatroom & Gameroom 28 Window 3.8 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Morning & Kitchen 29 Window 21.3 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Morning & Kitchen 30 Window 14.7 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Morning & Kitchen 31 Window 21.3 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Morning & Kitchen 32 Window 42.7 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Morning & Kitchen (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len Hat Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 8.0 2.7 10.0 0.1 10.0 10.0 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 10.0 9.0 8.0 0.1 8.0 8.0 27 Bug Screen 0.76 10.0 20.0 10.0 0.1 10.0 10.0 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 8.0 2.7 10.0 0.1 10.0 10.0 32 Bug Screen 0.76 8.0 2.7 10.0 0.1 10.01 10.0 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-16717:26:21 ID: Page 9 of 45 • ML : CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Villanueva Residence v �`. Building Type m Single Family 0 Addition Alone 0 Multi Family ❑ Existing+ Addition/Alteration Date 1511612011 OPAQUE SURFACE DETAILS Surface Type Area U-• ' Insulation Joint Appendix. Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 497 0.026 R-38 - 0 20 New 4.2.1-A9 Bedroom 4 Wall 161 0.069 R-21 ti 321 90 New 4.3.1-A6 Bedroom 4 Wall 29 0.069 R-21 51 90 New 4.3.1-A6 Bedroom 4 Wall 163 0.069 R-21 141 90 New 4.3.1-A6 Bedroom 4 Wall 241 0.069 R-21 231 "90 New 4.3.1-A6 Bedroom 4 Roof 1,192 0.026 R-38 0 20 New 4.2.1-A9 Bedroom 3, Guest Casita Wall 267 0.069 R-21 321 90 New 4.3.1-A6 Bedroom 3, Guest Casita Wall 601 0.069 R-21 51 90 New . 4.3.1-A6 Bedroom 3, Guest Casita Wall 523 0.069 R-21 141 •90 New 4.3.1-A6 Bedroom 3, Guest Casita Wall 343 0.069 R-21 231 90 New 4.3.1-A6 Bedroom 3, Guest Casita Slab 538 . 0.730 None 01- .180 New 4.4.7-A1 • Bedroom 3, Guest Casita Slab 320 0.730 None 0 180 New 4.4.7-A1 Bedroom 3, Guest Casita Floor 289 0.037 R-19 0 180 New 4.4.1-A4 Bedroom 3, Guest Casita FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status- Glazing Type Location/Comments 33 Window 21.3 0.360 NFRC 0.26 NFRC • 141 New ' Dual Non -Metal Tinted. Morning & Kitchen 34 Window 8.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Morning & Kitchen 35 Window 42.7 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Morning & Kitchen 36 Window 30.0 0.360 NFRC 0.26 NFRC 231 New, Dual Non -Metal Tinted. Moming & Kitchen 37 Window 5.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Morning & Kitchen 38 Window 42.7 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Morning & Kitchen 39 Window 30.0 0.360 NFRC 0.26 NFRC . 231 New Dual Non -Metal Tinted. Morning & Kitchen 40 Window 14.7 0.360 NFRC 0.26 NFRC '231 New Dual Non -Metal Tinted. Moming & Kitchen 41 Window 30.0 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Dining & Stairway 42 Window 5.0 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Dining & Stairway 43 Window 30.0 0.360 NFRC 0.26 NFRC 51 New, Dual Non -Metal Tinted. - Dining & Stairway 44 JWndow 30.0 0.360 NFRC 0.26 NFRC" • 51 New Dual Non -Metal Tinted. Dining & Stairway 45 Window 21.3 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 46 . Window. 21.3 0.360 NFRC 0.26 NFRC x.141 New Dual Non -Metal Tinted. Dining & Stairway 47 Window 14.7 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 48 Window 10.0 0.360 NFRC 0.26 NFRC -.141 New' Dual Non -Metal Tinted. `• Dining & Stairway (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type:, 116-B = Default Table from Standards, NFRC = Labeled Value i EXTERIOR SHADING DETAILS ID Exterior Shade. Type SHGC Window H t Wd -. Ove hang Left Fin Len H t. LExt RExt Dist Len-. Right Fin H t. Dist Len H t 33 Bug Screen 0.76 8.0 '2.7 10.0 0.1 10.0 10.0 34 Bug Screen 0.76 8.0 2.2 10.0 0.1 10.0 10.0 35 Bug Screen 0.76 8.0 2.7 10.0 0.1 10.0 10.0 36 Bug Screen 0.76 8.0 2.2 10.0 0.1 10.0 10.0 37 Bug Screen . 0.76 8.0 -3.3 10.0 0.1 10.0 10.0 38 Bug Screen .0.76 8.0 2.7 10.0 0.1 10.0 10.0 39 Bug Screen , 0.76 .-8.0 . *. 3.3 10.0 0.1 10.0 10.0 . 40 Bug Screen 0.76 6.0 4.0 10.0 0.1 10.0 10.0 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen + 0.76 48 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712. RunCode: 2011-05-16T17:26:21 ID: Pae 10 of 45 C C� J L� CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Villanueva Residence Building Type o Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1511612011 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments ------------- FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 42.7 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 50 Window 10.5 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 51 Window 21.3 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 52 Window 21.3 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 53 Window 21.3 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Dining & Stairway 54 Window 21.3 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 4 55 Window 42.7 0.360 NFRC 0.26 1 NFRC 141 New Dual Non -Metal Tinted. Bedroom 4 56 Window 8.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 4 57 Window 30.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 4 58 Window 60.0 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 59 Window 21.3 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 60 Window 21.3 0.360 NFRC 0.26 NFRC 321 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 61 Window 30.0 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 62 Window 30.01 0.360 1 NFRC 1 0.26 1 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 63 Window 30.01 0.360 1 NFRC 1 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 64Window 17.31 0.360 1 NFRC 1 0.26 NFRC 1 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len Hat Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 10.0 20.0 10.0 0.1 10.0 10.0 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16717:26:21 ID: Pae 11 of 45 • 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Villanueva Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 5/16/2011 OPAQUE SURFACE DETAILS Surface U Insulation Joint Appendix Tvoe I Area I Factor I Cavitv I Exterior Frame -Interiorl Frame I Azm I Tilt I Status 1 4 1 Location/Comments FENESTRATION SURFACE DETAILS Bug Screen 0.76 ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 65 Window 17.3 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 66 Window 21.3 0.360 NFRC 0.26 NFRC 51 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 67 Window 30.0 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 68 Window 17.3 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 69 Window 17.3 0.360 NFRC 0.26 NFRC 141 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 70 Window 30.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 71 Window 20.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 72 Window 42.7 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 73 Window 5.0 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 74 Window 23.3 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 75 Window 42.7 0.360 NFRC 0.26 NFRC 231 New Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 76 Window 21.31 0.360 NFRC 0.26 NFRC 231 New I Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 77 Window 1 42.71 0.360 NFRC 0.26 1 NFRC 2311 New I Dual Non -Metal Tinted. Bedroom 3, Guest Casita 1 & 2 (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade TVDe SHGC Hat I Wd Len Hat LExt REA Dist Len I H t Dist Len Hat 65 Bug Screen 0.76 66 Bug Screen 0.76 67 Bug Screen 0.76 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 71 Bug Screen 0.76 8.0 1.8 6.0 0.1 6.0 6.0 72 Bug Screen 0.76 8.0 5.3 6.0 0.1 6.0 6.0 73 Bug Screen 0.76 8.0 1.8 6.0 0.1 6.0 6.0 74 Buo Screen 0.76 8.0 1.8 6.0 0.1 6.0 6.0 75 Bug Screen 0.76 8.0 5.3 10.0 0.1 10.0 10.0 76 IBug, Screen 0.761 8.01 1.81 10.01 0.11 10.01 10.0 77 Bug Screen 0.761 8.01 4.31 10.01 0.11 10.01 10.0 I EnergyPro 5.1 by EnergySoft User Number: 6712 Runcode: 2011-05-16T17:26:21 /D: Page 12 of 45 1 AdL • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Villanueva Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/16/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Master Suite 1,169 14,028 Bedroom 2 460 5,520 HVAC 2 & 3 Greatroom & Gameroom 2,137 27,781 HVAC 4 Moming & Kitchen 1,266 15,192 HVAC 5 Dining & Stairway 930 11,160 Bedroom 4 497 4,970 HVAC 6 Beroom 3, & Guest Casita 1 & 2 1,318 19,770 Totals 7,777 01 01 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 4 1 Central Furnace 80% AFUE S lit Air Conditioner 14.0 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 6 1 Central Furnace 80% AFUE I Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.01 New HVAC 6 Ducted Ducted I Attic, Ceiling Ins, vented 1 8.01 New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White M -1-100T6 2 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c 0 .6 V) a — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. FHP Plenum Outside Buried EnergyPro 5. 1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 ID: Pae 13 of 45 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Villanueva Residence Date 1 5/16/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui ped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 (j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 2011-05-16717:26:21 ID: Page 14 of 45 1� MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Villanueva Residence 5/1 _Oil §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ftz may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 ID: Page 15 of 45 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date AS Villanueva Residence 1511612011 Wit §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off-switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with•Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130 d . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 /D: Page 16 of 45 r HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Villanueva Residence Date 5/16/2011 System Name HVAC 1 Floor Area 1,629 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,747 27,890 Return Vented Lighting 0 Return Air Ducts 1,314 Return Fan 01 Ventilation F 0 0 Supply Fan 2,978 Supply Air Ducts 1,314 TOTAL SYSTEM LOAD 1 33,496 COIL HTG. Latent CFM 4,417 541 0 0 4,417 PEAK Heating System Sensible Output perSystem 89,000 24,393 Total Output Btuh 89,000 Output Btuh/s ft 54.6 931 Cooling System 0 Output perS stem 57,500 0 Total Output Btuh 57,500 -2,978 Total Output Tons 4.8 931 Total Output Btuh/s ft 35.3 Total Output s ft/Ton 340.0 23,278 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACA460/58CVX090 37,539 9,544 89,000 Airflow cfm/s ft 1.23 1 89,000 I Jan 1 AM Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 37,539 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 9,544 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 113 OF 115 OF nk < G Supply Fan Heating Coil 114 OF 2,000 cfm "T ROOM 72 OF COOLING SYSTEM PSYCHROMETICS(Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air A. 0 cfm 71 / 60 OF 71/60°F 53/52°F 54/53°F Cooling Coil Supply Fan 2,000 cfm 54.5% 55 / 53 OF ;--- _--- .---- ...--............ .... I ROOM 70 / 60 OF EnergyPro 5.1 by EnergySoff User Number: 6712 Run Code: 2011-05-16T17:26:21 /D: Page 17 of 45 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Villanueva Residence Date 5/16/2011 System Name HVAC 2 & 3 Floor Area 2,137 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING CFM Sensible Total Room Loads 1,549 29,561 Return Vented Lighting 0 Return Air Ducts 1,393 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1,393 TOTAL SYSTEM LOAD 32,347 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 89,000 4,496 565 30,998 Total Output Btuh 178,000 Output Btuh/s ft 83.3 1,183 Cooling System 0 Output perSystem 46,500 0 0 0 Total Output Btuh 93,000 4,496 0 Total Output Tons 7.8 1,183 Total Output Btuhls ft 43.5 Total Output (sq-ft/Ton 275.7 33,365 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Carrier 24ACA448/58CVX090 63,868 11,030 178,000 Airflow cfm/s ft 1.50 Airflow cfm/Ton 412.9 Outside Air °i° 0.0% Total Adjusted System Output 63,868 11,030 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 178,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 124 OF 124 OF x Outside Air • 0 cfm Heating Coil Supply Fan ° 124 F 3,200 cfm ROOM 72 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 70/59°F 52/51 OF 52/51 OF hLJ Outside Air 0 cfm Cooling Coil Supply Fan 52 / 51 OF 3,200 cfmp_..._._ ................._._........... 50.7% '.ROOM 70 / 59 OF 70 ! 59 OF EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2011=05-16717:26:21 /D: Page 18 of 45 C� J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Villanueva Residence Date 5/16/2011 System Name HVAC 4 Floor Area 1,266 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 839 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts, TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 15,682 2,989 324 17,770 Total Output Btuh 89,000 0 Output Btuh/s ft 70.3 739 678 Cooling System 0 0 Output per System 46,500 0 0 0 0 Total Output Btuh 46,500 0 2,989 0 Total Output Tons 3.9 1 7391 678 Total Output Btuh/s ft 36.7 Total Output s ftfTon 326.7 1 17,159 19,127 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ACA448/58CVX090 31,367 6,298 89,000 Airflow cfm/s ft 1.26 Airflow cfmfTon 412.9 Outside Air % 0.0 % Total Adjusted System Output 31,367 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 6,298 Aug 3M 89,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 124 OF 124 OF t„ Heating Coil Supply Fan 1,600 cfm 123 ° F • ROOM 72 OF 0.. 1': 1 , J COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/59°F 70/59°F 52/51 OF 52/51 OF Cooling Coil Supply Fan 52 / 51 OF 1,600 cfm........................................................ 52.1 ROOM 70/59°F EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16717:26:21 /D: Page 19 of 45 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Villanueva Residence 5/16/2011 System Name Floor Area HVAC 5 1,427 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total' Room Loads 1,424 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 23,211 4,068 447 20,210 Total Output Btuh 89,000 0 Output Btuh/s ft 62.4 1,094 771 Cooling System 0 0 Output per System 57,500 0 0 0 0 Total Output Btuh 57,500 2,978 4,068 -2,978 Total Output Tons 4.8 1,094 771 Total Output Btuh/s ft 40.3 Total Output s ft/Ton 297.8 1 28,376 1 18,775 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACA460/58CVX090 37,754 9,178 89,000 Alrflow cfm/s ft 1.40 Airflow cfm/Ton 417.4 89,000 Jan 1 AM Outside Alr % 0.0 % Total Adjusted System Output 1 37,7541 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 9,178 Aug 3 PM Outside Air cfm/s ft 0.00 above given at ARI conditions Hvalues ING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 113 OF 115 °F f 72 Outside Air 0 cfm Heating Coil Supply Fan o 114 F 2,000 cfm ROOM 72 OF L. LA. 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71 /60°F 53/52°F 54!53°F c %pn�-� Outside Air 0 cfm Cooling Coil Supply Fan 55153 OF 2,000 cfm ............... .......... _....... ._........... .1 � 53.9% ROOM 71 / 60 OF 70159 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16717:26:21 /D: Page 20 of 45 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Villanueva Residence Date 5/16/2011 System Name HVAC 6 Floor Area 1,318 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,442 Return Vented Lighting Return Air Ducts Return Fan Ventilation E 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 24,000 3,079 582 26,191 Total Output Btuh 89,000 0 Output Btuh/s ft 67.5 1,131 1,000 Cooling System 0 0 Output per System 57,5001 0 0 0 0 Total Output Btuh 57,500 2,978 3,079 -2,978 Total Output Tons 4.8 1 1,131 1,000 Total Output Btuh/s ft 43.6 Total Output s ft/Ton 275.1 1 29,240 25,213 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACA460/58CVX090 38,518 8,149 89,000 Airflow cfm/s ft 1.52 1 89,000 Jan 1 AM Airflow cfm/Ton 417.4 Outside Air % 0.0% Total Adjusted System Output 1 38,518 8,149 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 113 OF 115 OF — Outside Air Supply Fan 0 cfm Heating Coil 114 OF 2,000 cfm _ -ROOM'l_ 72 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71/59°F 52/52°F' 54/52°F Outside Air 0 cfm Cooling Coil Supply Fan 54 / 52 OF 2,000 cfm.................................................... 52.4% ROOM' I 71!59°F 70/59°F EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 /D: Page 21 of 45 • • • ROOM LOAD SUMMARY 4,417 541 24,393 Project Name Villanueva Residence 4,417 541 Date 5/16/2011 System Name HVAC 1 Floor Area 1,629 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite Master Suite 1 1,171 18,699 2,822 1,171 18,699 2,822 362 16,290 Bedroom 2 Bedroom 2 1 1 576 9,191 1,596 576 9,191 1,596 180 8,103 PAGE TOTAL TOTAL* 1,747 27,890 4,417 541 24,393 1,747 27,890 4,417 541 24,393 * Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-05-16T17:26:21 ID: Page 22 of 45 F--7 ROOM LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 System Name Floor Area HVAC 2&3 2,137 ROOM LOAD SUMMARY ROOM COOLING PEAK 'COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Greatroom & Gameroom Greatroom & Gameroom 1 1,549 29,561 4,496 1,549 29,561 4,496 565 30,998 i PAGE TOTAL TOTAL. Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnemySoft User Number 6712 RunCode: 2011-05-16T17:26 1,549 29,561 4,496 565 30,998 1,549 29,5611 4,4961 565 30,998 e 23 of 45 C] • 0 ROOM LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 System Name Floor Area HVAC 4 1,266 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM Sensible Latent I CFM Sensible Moming & Kitchen Morning & Kitchen 1 8361 15,6821 2,989 839 15,6821 2,9891 3241 17,770 Total includes ventilation load for zonal EnergyPro 5.1 by EnemySoR User N PAGE TOTAL TOTAL 839 15,682 2,989 324 17,770 8391 15,682 2,989 324 17,770 - PAGE TOTAL TOTAL " ' Total includes ventilation load for zonal systems. Ene Pro 5.1 b Ene Soft User Number. 6712 Run Code: 2011-05-16T17:26:21 /D: 1,424 23,211 4,068 447 20,210 1,424 ROOM LOAD SUMMARY 4,068 447 20,210 •Villanueva Project Name Residence Date 5/16/2011 System Name HVAC 5 Floor Area 1,427 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Dining & Stairway Dining & Stairway 1 920 14,988 2,408 920 14,988 2,408 316 14,292 Bedroom 4 Bedroom 4 1 505 8,222 1,660 505 8,222 1,660 131 5,918 4 - PAGE TOTAL TOTAL " ' Total includes ventilation load for zonal systems. Ene Pro 5.1 b Ene Soft User Number. 6712 Run Code: 2011-05-16T17:26:21 /D: 1,424 23,211 4,068 447 20,210 1,424 23,211 4,068 447 20,210 LJ C ROOM HEATING PEAK LOADS Project Name Villanueva Residence Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 1,169.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT OF X 46 X 46 X 46 X 46 X 46 X X X X X X X X X X X X X X X X X X X X X X X X X X Page Total /60] X AT Btu/hr = 1,369 = 607 = 2,280 = 4,897 = 3,022 = = = = = = = = = = = = = = = = = = = = _ = = = 1 12,175 46 = 4,115 R-38 Roof(R.38.2x14.16) 1,145.0 0.0260 Double Non Metal Clear 24.0 0.5500 R-21 Wall (W.19.2x6.16) 718.3 0.0690 Dual Non -Metal Tinted. 295.7 0.3600 Slab -On -Grade perim = 90.0 0.7300 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,169 X Area another room 12.00 X 0.360 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 16,290 Energ Pro 5.1 by EnergySoR User Number: 6712 Run Code: 2011-05-16T17:26:21 ID: Page 27 of 45 • ROOM HEATING PEAK LOADS Project Name Villanueva Residence Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Floor Area 460.0 ftz Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area - X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = — = = = = = = = = — = _ = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 460.0 0.0260 46 550 R-21 Wall (W.19.2x6.16) 429.7 0.0690 46 1,364 Dual Non -Metal Tinted. 156.3 0.3600 46 2,588 Slab -On -Grade perim = 59.0 0.7300 46 1,981 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 460 X Area another room 12.00 X 0.360 Height ACH Page Total /60] X AT 6,484 = 1,619 TOTAL HOURLY HEAT LOSS FOR ROOM 8,103 EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2011-05-16717:26:21 /D: Page 28 of 45 r� LJ ROOM HEATING PEAK LOADS Project Name Villanueva Residence Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Greatroom & Gameroom Floor Area 2,137.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = _ = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 2,137.0 0.0260 46 2,556 R-21 Wall (W.19.2x6.16) 1,316.9 0.0690 46 4,180 Dual Non -Metal Tinted. 662.1 0.3600 46 10,964 Slab -On -Grade perim = 172.0 0.7300 46 5,776 L Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,137 X Area another room 13.00 X 0.332 Height ACH Page Total /60] X AT 23,476 = 7,522 TOTAL HOURLY HEAT LOSS FOR ROOM 30,9 EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-05-16T17:26:21 /D: Page 29 of 45 • • • ROOM HEATING PEAK LOADS Project Name Villanueva Residence Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Morning & Kitchen Floor Area 1,266.0 ftZ Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X. X X X to Ceiling U -Value AT *F X 46 X 46 X 46 X 46 X X X X X X X X X X X X X X X X X X X X X X X X X X X Page Total /60] X AT Btu/hr c 1,514 c 3,100 c 4,938 c 3,761 = = = = _ = = _ = = _ = _ _ _ _ = = = _ _ _ 13,314 46 = 4,456 R-38 Roof(R.38.2x14.16) 1,266.0 0.0260 R-21 Wall (W.19.2x6.16) 976.8 0.0690 Dual Non -Metal Tinted. 298.2 0.3600 Slab -On -Grade perm = 112.0 0.7300 ^ Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,266 X Area another room 12.00 j( 0.360 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 17,770 EnergyPro 5.1 by Energ Soft User Number. 6712 Run Code: 2011-05-16717:26:21 /D: Page 30 of 45 • C ROOM HEATING PEAK LOADS Project Name Villanueva Residence Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining & Stairway Floor Area 930.0 ftZ Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 492.0 X 966.6 X 24.0 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = _ = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 0.0260 46 588 R-21 Wall (W.19.2x6.16) 0.0690 46 3,068 Wood Door 0.5000 46 552 Dual Non -Metal Tinted. 279.4 X X 0.3600 46 4,627 Slab -On -Grade perm = 65.0 0.7300 46 2,183 X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 930 X Area Ceiling another room 12.00 X 0.360 Height ACH Page Total /60] X AT 11,018 = 3,274 TOTAL HOURLY HEAT LOSS FOR ROOM 14,292 EnergyPro 5.1 by EnergySoft User Number.' 6712 Run Code: 2011-05-16717:26:21 ID: Page 31 of 45 • 0 ROOM HEATING PEAK LOADS Project Name Villanueva Residence Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Floor Area 497.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = _ = = = = = = - = = 46 Btu/hr R-38 Roof(R.38.2x14.16) 497.0 X 0.0260 46 594 R-21 Wall (W.19.2x6.16) •594.0 X 0.0690 46 1,885 Dual Non -Metal Tinted. 102.0 X 0.3600 46 1,689 X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 497 X Area to another room 10.00 X 0.431 Ceiling Height ACH Page Total /60] X AT 4,169 = 1,749 TOTAL HOURLY HEAT LOSS FOR ROOM 5,918 Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-16T17:26:21 ID: Page 32 of 45 • C] W ROOM HEATING PEAK LOADS Project Name Villanueva Residence Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS. Room Name Beroom 3, & Guest Casita 1 & 2 Floor Area 1,318.0 ftz Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr R-38 Roof(R.38.2x14.16) 1,192.0 X X 0.0260 46 = = = 1,426 R-21 Wall (W.19.2x6.16) 1,735.2 0.0690 46 5,508 Dual Non -Metal Tinted. 540.8 X 0.3600 - 46 8,956 Slab -On -Grade peri. 154.0 X X 0.7300 46 = 5,171 R-19 Floor (F. 19.2x8.16) 289.0 0.0370 46 = 492 X = = X X = = = X X X X = X = = X X = = X X = X = X X = = X - X _ = - X X X X X = - = X = X = X = = Page Total /60] X 46 AT X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,318 X Area to another room 15:00 X 0.288 Ceiling Height ACH 21,552 = 4,639 TOTAL HOURLY HEAT LOSS FOR ROOM 26,191 Energ Pro 5.1 by Energ Soft User Number: 6712 Run Code: 2011-05-16717:26:21 /D: Page 33 of 45 • C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,169.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 1,145.0 X 0.0260 X 56.0 = 1,667 R-21 Wall (W.19.2x6.16) (SE) 459.3 X 0.0690 X 30.3 = 961 R-21 Wall (W. 19.2x6.16) (S 149 128.0 X 0.0690 X 31.3 = 276 R-21 Wall (W.19.2x6.16) (NW) 131.0 X 0.0690 X 29.9 = 270 X X = X X = X X = X X = X X I I= Page Total 3,175 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr skl -1 (N) 0.0 X 36.7 + 24.0 X 127.4 = 3,057 V2-2 (SE) 0.0 X 16.8 + 20.0 X 22.0 = 441 13-3 (SE) 0.0 X 16.8 + 42.7 X 22.0 = 941 E2-4 (SE) 0.0 X • 16.8 + 8.0 X 22.0 = 176 V1-5 (SE) X 16.8 + 20.0 X 22.0 = 441 16-6 (SW) X 16.8 + 66.6 X 23.1 = 2,943 17-7 d83.4 (NW) X 16.8 + 55.0 X 25.2 = 1,387 X + X = X +1 X = Page Total 6,386 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 63.97. X 42 = 3,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,699 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 1 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 63.97 X 0.00523 = 2,022 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,822 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2011-05-16717:26:21 /D: Page 34 of 45 • r: RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 460.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 460.0 X 0.0260 X 56.0 = 670 R-21 Wall (W 19.2x6.16) ,(NM 78.2 X 0.0690 X 29.9 = 161 R-21 Wall (W.19.2x6.16) (NE) 146.0 X 0.0690 X 29.5 = 298 R-21 Wall (W.19.2x6.16) (SE) 205.5 X 0.0690 X 30.3 = 430 X X = X X = X X = X X = X X = Page Total 1,559 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr B2-8 (NW) 0.0 X 16.8 + 21.3 X 25.2 = 537 7-9 (NIM 0.0 X 16.8 + 42.7 X 25.2 = 1,076 A2-10 (NK9 0.0 X 16.8 + 12.8 X 25.2 .= 323 U1-11 (SE) •0.0 X 16.8 + 12.0 X 22.0 = 265 12-12 (SE) 0.0 X 16.8 + 42.7 X 22.0 = 941 U1-13 (SE) 0.0 X 16.8 + 12.0 X 22.0 = 265 Al -14 (SE) 0.0 X 16.8 + 12.8 X 22.0 = 282 X + X = X +1 X = Page Total 3,688 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 25.17 X 42 = 1,424 Air Sensible CFM ELA AT, TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,191 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 25.17. X 0.00523 = 796 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,596 EnerqvPro 5.1 by EnemySoft User Number: 6712 Runcode: 2011-05-16717:26:21 /D: Page 35 of 45 0 0 I RESIDENTIAL ROOM COOLING LOAD SUMMARY I 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Greatroom & Gameroom Outdoor Dry Bulb Temperature 112 OF Floor Area 2,137.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W..19.2x6.16) Orientation I (NW)1 Area X X X X X X X XX X U -Factor X X X X X X X X CLTD' = = = = = = = = = 2,137.0 0.0260 56.0 318.3 0.0690 29.9 400.3 0.0690 29.5 317.0 0.0690 30.3 281.3 0.0690 31.3 26.2 = 0.0 150.0 X 26.2 = X 26.2 = X 26.2 = X 1 23.1 = Page Total 0.0 14.7 2.6 18.7 0.0 10.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 19-15 N1-16 J2-17 1-18 M2-19 9-20 N2-21 8-22 H2-23 . Orientatinn (Nutt (NVI0 (NE) (NE) (NE) (NE) (NE) (NE) (SK9 . Btu/hr 3,111 656 816 663 607 I , 5,8531 Shaded Area X X X X X X X X X1, GLF 16:8 + 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + , 16.8 +1 Unshaded Area GLF X 25.2 = 0.0 63.0 0.0 14.7 X X X 25.2 = = = 0.0 14.7 26.2 0.0 36.0 26.2 0.0 20.01 X 26.2 = 0.0 150.0 X 26.2 = X 26.2 = X 26.2 = X 1 23.1 = Page Total 0.0 14.7 2.6 18.7 0.0 10.0 Btu/hr 1,588 371 384 941 523 3,923 384 533 231 8,879 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 Air Sensible X 1.27 CFM X 116.94 ELA X 42 = 6,614 AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,561 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 1 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 116.94 X 0.00523 = 3,696 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4.4961 • r: • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Villanueva Residence 1 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room.Name Greatroom & Gameroom Outdoor Dry Bulb Temperature 112 OF Floor Area 2,137.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 13-24 IS K9 0.0 X 16.8 + 42.7 X 23.1 = 986 U2-25 (SIM 0.0 X 16.8 + 12.0 X 23.1 = 277 18-26 (SK9 63.0 X 16.8 + 0.0 X 23.1 = 1,061 20-27 (S KO 200.0 X 16.8 + 0.0 X 23.1 = 3,370 X + X = X + X - X + X = X + X = X + X = Page Total 5,694 Internal Gain Btu/hr— tu/hrOccu Occupants ants 4.0 Occupants X 230 Btuh/occ. =920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 116.94 X 42 = 6,614 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,561 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 116.94 X 0.00523 = . 3,696 Air Sensible CFM ELA AW v TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,496 EnemyPro 5.1 6 Y EnemySoft User Number: 6712 Run Code: 2011-05-16717:26:21 /D: Page 37 of 45 0 0 RESIDENTIAL ROOM COOLING Project Name Villanueva Residence SUMMARY Date 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Morning & Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,266.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor, CLTD' R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) --�:J - 1,266.0 X X X X X X X X X 0.0260 X X X X X X X X X 56.0 = = = = = = = = 478.2 0.0690 29.9 120.0 0.0690 29.5 58.7 0.0690 30.3 319.9 0.0690 31.3 0.0 0.0 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,682 Latent Gain Btu/hr Occupants J I= Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration R1-28 24-29 Dl -30 Q4-31 22-32 Q3-33 E1-34 21-35 K1-36 Orientation (NtM (NIM (NIM (SE) (SE) (SE) (SIM (StM (SIM Shaded Area X X X X X X X X X GLF 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + 16.8 + Unshaded Area GLF X 25.2 X 25.2 X 25.2 X 22.0 X 22.0 X 22.0 X 23.1 X 23.1 X 23.1 Page Total = = = = = = = = = 0.0 0.0 3.8 21.3 0.0 14.7 21.3 0.0 42.7 0.0 21.3 8.0 42.7 30.0 0.0 0.0 0.0 0.0 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Btu/hr 1,843 985 245 123 690 Btu/hr 96 537 371 359 719 359 135 719 505 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 69.28 X 42 _ 3,919 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,682 Latent Gain Btu/hr Occupants 4.0 Occupants. X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 69.28 X 0.00523 = 2,189 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Morning & Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,266.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr G1-37 (S119 5.0 X 16.8 + 0.0 X 23.1 = 84 23-38 (s K9 42.7 X 16.8 + 0.0 X 23.1 = 719 D3-39 (Std 30.0 X 16.8 + 0.0 X 23.1 = 505 D2-40 (S K9 14.7 X 16.8 + 0.0 X 23.1 = 248 X + X = X + X - X + X - X + X = X +1 X = Page Total 1,557 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 69.28 X 42 = 3,919 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,682 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 69.28 X 0.00523 = 2,189 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR. ROOM 2,989 EnergyPro, 5.1 bV Ene Soft User Number. 6712 RunCode: 2011-05-16717:26:21 /D: Page 39 of 45 � KI I0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Villanueva Residence ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temoer,, Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) Wood Door R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Dining & Stairway Outdoor Dry Bulb Temperature 930.0 ft2 Outdoor Wet Bulb Temperature 70 OF Outdoor Daily Range: Orientation (N) 5/16/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 492.0 0.0260 56.0 440.0 0.0690 29.9 24.0 0.5000 29.9 179.0 0.0690 29.5 347.6 0.0690 30.3 16.8 21.3 22.0 0.0 16.8 21.3 22.0 0.0 16.8 14.7 22.0 0.0 Page Total L Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF D4-41 G 1-42 F4-43 F3-44 3-45 81-46 J1-47 H1-48 2-49 (NI/10 (NKq (NE) (NE) (SE) (SE) (SE) (SE) (SE) 0.0 X X X X X X X X X 16.8 + + + + + + + + + 30.0 X X X X X X X X X 25.2 = = = = = = = = = 0.0 16.8 5.0 25.2 0.0 16.8 30.0 26.2 0.0 16.8 30.0 26.2 0.01 16.8 21.3 22.0 0.0 16.8 21.3 22.0 0.0 16.8 14.7 22.0 0.0 16.8 10.0 22.0 0.0 16.8 42.7 22.01 Internal Gain Occupants 4.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.27 X 50.89 X Air Sensible CFM ELA AT Page Total 112 OF 78 OF 34 OF Btu/hr 71s 358 365 728 3,0741 Btu/hr 756 126 785 785 470 470 324 220 941 4,876 Btu/hr 920 = 1,600 2,879 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14.9861 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ: = 800 Infiltration: 4,771 X 1.27 X 50.89 X 0.00523 = 1,608 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.408 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Dining & Stairway Outdoor Dry Bulb Temperature 112 OF Floor Area 930.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr N3-50 (SE) 0.0 X 16.8 + 10.5 X 22.0 = 231 66-51 (SE) 0.0 X 16.8 + 21.3 X 22.0 = 470 Q1-52 (SE) 0.0 X 16.8 + 21.3 X 22.0 = 470 Q3-53 (SE) 0.0 X 16.8 + 21.3 X 22.0 = 470 X + X - X + X - X + X - X + X - X 1 +1 X = Page Total 1,640 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 50.89 X 42 = 2,879 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,988 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 50.89 X 0.00523 =* 1,608 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,408 Ene Pro 5. 1 by Ene Soft User Number. 6712 Run Code:2011-05-16717:26:21 /D: Page 41 of 45 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 497.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (N) 497.0 X 0.0260 X 56.0 = 724 R-21 Wall (W.19.2x6.16) (NlAq 161.0 X 0.0690 X 29.9 = 332 R-21 Wall (W.19.2x6.16) (NE) 28.7 X 0.0690 X 29.5 = 58 R-21 Wall (W.19.2x6.16) (SE) 163.3 X 0.0690 X 30.3 = 342 R-21 Wall (W.19.2x6.16) (Sly 241.0 X 0.0690 X 31.3 = 520 X X = X X = X X = X X = Page Total 1,976 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Q2-54 (NE) 0.0 X 16.8 + 21.3 X 26.2 = 557 61-55 (SE) 0.0 X 16.8 + 42.7 X 22.0 = 941 E1-56 (SK9 0.0 X 16.8 + 8.0 X 23.1 = 185 K1-57 (Sim 30.0 X 16.8 + 0.0 X 23.1 = 505 X + X = X + X - X + X - X + X = X +1 X = Page Total 2,188 Internal Gain Btu/hr- tu/hrOccu Occupants ants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 27.20 X 42 = 1,538 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,222 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. _ - 800 Infiltration: 4,771 X 1.27 X 27.20 X 0.00523 = 860 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,660 EnemyPro 5. 1 by EnemySoft User Number: 6712 Run Code: 2011-05-16T17:26:21 /D: Pa a 42 of 45 a _0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Villanueva Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Beroom 3, & Guest Casita 1 & 2 Outdoor Dry Bulb Temperature Floor Area 1,318.0 ft2 Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: Opaaue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-19 Floor (F. 19.2x8.16) Orientation (NE) (SE) (SIM Date 5/16/2011 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,192.0 0.0260 56.0 267.4 0.0690 29.9 601.1 0.0690 29.5 523.4 0.0690 30.3 343.3 0.0690 31.3 289.0 0.0370 19.0 0.0 X 16.8 + 30.0 26.2 0.0 X 16.8 + 30.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration S1-58 67-59 Q4-60 K2-61 F4-62 F5-63 P1-64' P2-65 71-66 Orientation (NIM (NW) (NKK (NE) (NE) (NE) (NE) (NE) (NE) 112 OF 78 OF 34 OF Btu/hr 1,736 551 1,225 1,095 741 203 1 5,5511 Shaded Area GLF Unshaded Area X X X X X X X X XI GLF = = = = = = = = = 0.0 X 16.8 + 60.0 25.2 0.0 X 16.8 + 21.3 25.2 0.0.X 16.8 + 21.3 25.2 0.0 X 16.8 + 30.0 26.2 0.0 X 16.8 + 30.0 26.2 0.0 X 16.8 + 30.0 26.2 0.0 X 0.0 X 0.01 X 16.8 + 17.3 26.2 16.8 + 17.3 26.2 1 16.8 +1 21.3 26.2 Page Total Btu/hr 1,513 537 537 785 785 452 452 557 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. ` Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.27 X 72.12 X 42 = C Air Sensible CFM ELA , AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,000 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 72.12 X 0.00523 = 2,279 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3.0791 ve .0 RESIDENTIAL ROOM COOLING LOAD SUMMARY 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Beroom 3, & Guest Casita 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,318.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF ue Surfaces Orientation Area X X -X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = _ GLF = = = = = = = = = 0.0 16.8 30.0 22.0 0.0 16.8 17.3 22.0 0.0 16.8 17.3 22.0 0.0 16.8 30.0 23.1 20.0 16.8 0.01 23.1 42.7 16.8 0.0 23.1 5.0 16.8 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestratinn D3-67 P2-68 P1-69 D4-70 M1-71 5-72 C1-73 Q1-74 4-75 Orientation (SE) (SE) (SE) (SIA9 (SIAL (SVIO (SV19 (SV19 (SV19 Area X X X X X X X X X GLF + +. + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 16.8 30.0 22.0 0.0 16.8 17.3 22.0 0.0 16.8 17.3 22.0 0.0 16.8 30.0 23.1 20.0 16.8 0.01 23.1 42.7 16.8 0.0 23.1 5.0 16.8 0.0 23.1 23.3 16.8 0.0 23.1 42.7 16.8 0.0 23.1 Page Total Btu/hr 01 Btu/hr 661 A93 337 719 84 393 719 4,369 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.27 X 72.12 X 42 = 4,079 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,0001 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X • 72.12 X 1 2,279 Air Sensible CFM ELA AW 0 i TOTAL HOURLY LATENT HEAT GAIN FOR ROOM .0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Villanueva Residence 5/16/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Beroom 3, & Guest Casita 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,318.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X. X = X X = X X = Page Total 1 0 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Q1-76 (StM 21.3 X 16.8 + 0.0 X 23.1 = 359 68-77 (S K9 42.7 X 16.8 + 0.0 X 23.1 = 719 t X + X = X + X = X + X - X + X = X' + X = X + X - X +1 X - Page Total 1,078 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 72.12 X 42 = 4,079 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,000 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 72.12 X 0.00523 = 2,279 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,079 Ener.gyPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2011-05-16T17:26:21 /D: Page 45 of 45