Loading...
12-0023 (SOL)P.O. BOXf 1504' 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: LOA 104C Mr 12-00000023 80325 VIA PESSARO ' 777-180-012- - - SOLAR LOW DENSITY RESIDENTIAL 52000 t 4 ul�cv BUILDING & SAFETY DEPARTMENT BUILDING PERMIT , Owner: , VILLANUEVA FAMILY 3807 42ND AVE NE ' SEATTLE, WA 98105 Architect or Engineer: ' Contractor: VINTAGE ELECTRIC 48587 MARIN COURT INDIO, CA 92201 (760)775-0135 Lia_ No.: 481352 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/03/12 - - - - - - - - - - - - - - - - - - - - - - - - - -'- - - - - - - - - - - - - - - _ - _- -- - - - - - - - - - - -'- - - - - - - - - - - --- - - _ - - - - - - - - - - - - - - - - - - - , - LICENSED CONTRACTOR'S DECLARATION; -- - - WORKER'S COMPENSATION. DECLARATION - I hereby affirm underpenalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Clas : 10 C46 License No.: 481352 , for by Section 3700 of the Labor Code, for the performance of the work for which this permit is Date: f IContractor: V I ` c�'`�� �t �- _ issued. -_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor • - - Code, for the performance of the work for which this permit is issued.. My workers' compensation OWNER -BUILDER DECLARATION- insurance carrier and policy number are: rCarrier I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the STATE FUND - - - Policy Number 90059i4-12 following reason (Sec. 7031.5, Business and Professions Code: 'Any city or county that requires a permit to -- _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, - - permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State- and agree that, if 1 should become subject to the workers' compensation provisionsof Section , License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 3700 of the Labor Cyde, I shall forthwith c mply ith•those provisions. / ,•V/'I ..(L�`Lt,� F wl - any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500) - _ Date: l Z Applicant: - - o — �•' 0""' J (_) I, as owner of the property, or my employees with wages as their sole compensation,' will do the work, and ' the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL - Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES•UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. -,..+.. ' - one year of completion, the owner -builder will have the burden of proving that he or she did not build or - - .. improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT •' (_) I, as owner of the property, am exclusively contracting withlicensed contractors to construct the project (Sec. IMPORTANT Application is,hereby made to the Director of Building and Safety for a permit subject to the • 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.)• whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_) I. am exempt under Sec. , BAP.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City - of La Quinta, its officers, agents and employees for any, act or omission related to the work being - - performed under or following issuance of this permit. -. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced - within 180 days from date of issuance of such permit, or cessationof work for 180 days will subject '. • CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the - I certify that I have read this application and state that the above information is correct. I agree to comply with' all, work for which this permit is issued (Sec. 3097, Civ. C.)• city and county ordinances and state laws relating to building construction, and hereby authorize representatives - of this co my to enter upon the above-mentioned property for'nb o - spection pu.ti • Lender's Name: - - �' I s - DateSignature (Applicant or Agent): - Lender's Address:. - LQPERMIT Application Number .. . . . . 12-00000023 ' i Permit SOLAR PERMIT Additional desc ' Permit Fee- 22.50 Plan Check - Fee 5.63 Issue Date. Valuation 52000 Expiration Date 10/30/12 ' 'Qty Unit Charge Per Extension BASE FEE a 15.00 - r 1.00 4.5000 EA SOLAR COLLECTOR.< 1000 4.50 1.00. 3.000O+EA SOLAR EQUIP MISCELLANEOUS- 3.00 -------_------------------------------------------------------------------- , Permit .. ELEC-MISCELLANEOUS •. r. Additional desc ..• , r . •`Permit Fee . . . 22.50 .Plan Check Fee 5.63 - Issue Date Valuation 0 k. _ Expiration Date 10/30/12 ' fQty Unit Charge" Per _.Extension `•" BASE FEE ,., 15.00 t'"• - 1.00 -7.5000 EA' ELEC PWR APP >1 TO '<=10 ' L .-7.50 �: a ___ _______4 -.-____ __ t _a_ �- j__77 Special Notes and COmmentS• _ � ___ 10.4kW SOLAR ARRAY - (42)..248W HYUNDAI ` PANELS W/ (1) 8,000W SMA AMERICA "t ' INVERTER (.714SFj 2010• CALIFORNIA ELECTRICAL CODE., May 2,-2012 9:58:38 AM AORTEGA -----------------`----------------------------------t-------- - j Other Fees BLDG S.TDS:ADMIN (SB1473) -- ---- -r-- -- 3.00' + •` - Fee. summary Charged r;. Paid Credtedf: Due �, f ------------ -`------------ - ---- _-- _, -----"F' __--------- ---- -Permit Permit Fee Total � 45.00• '. 00 '00 45 00 , y . ' Plan Check Total 11 26` .00 .•00 ' 11.26 _ ' Other Fee Total' 3..00 .00 00• 3.00 .. _ Grand Total 59.26 .00 .00 59,26 LQPERMIT Bin # Gey of, la Quinta Building 8t Safety Division P.O. Box 1504,78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 BuildingPermit Application and Tracking Sheet Permit # Z� ` /� p Project Address: 3 2S �1 l A Owner's Name: A. P. Number: Address: �o32•S �/�o. IPtSSo rCry Legal Description: City; ST, Zip: tA q 2253 i Contractor, �1��0�9� �lt�tl✓► � 'o.r' `4 � Telephone: .�, : " ''.Z^'"• :s.::��'�,..s Address:t`��r\;', Project Description: 2, Sp�� IPV City, ST, Zip: 1 v\ A i O VT Z O \ ��v1s-E-a�� a ergs t ca'+ Z-V-% V' Ooh SSC Telephone: "1 too 'O 13 S State Lie. City Lie. #; ...h Arch., Engr., Designer: �L� V �N/v �� J .. I .sp� Address: City, ST, Zip: Telephone: P �, r n>c .' � • .,,, ,,. ;.:z<:� •�::,.,,, W ),. RL::S::�:�r..fo.'•:>:a ••y .sProJect Construction Type: Occupancy: . an State Lie. #: type (circle one): d-ID Add'n Alter Repair Demo Name of Contact Person: .J A VV\ V l 1�) Y• U , Sq. Ft.: # Stories: #Units: Telephone # of Contact Person: 'I Iwo \0 0 9 .Sq 3 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACIUNG PERMIT FEES Plan Sets p� Plan Check submitted IN Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit �— Truss Cales. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked upop Ity Construction S. 1-vv�2. Flood plain plan Plans resubmitted ,ZDn Mechanical .-. Grading plan 2'" Review, ready foco rectio issue ElectricalO Ime Subcontactor List Called Contact Person Plumbing �. Grant Deed Plans picked up S.M.I. H.O.A. Approval Q Plans resubmitted 0 Grading ' ..._ IN HOUSE:- m'd Review, ready for iorrectio meso N Developer Impact Fee Planning Approval Called Contact Person S A.I.P.P. Pub. Wks. Appr Date of permit issue S� V School Fees Total Permit Fees k 11 4� tion • �Q. 1KL. 5 ti .�ti� tom. ISD fey. 4Wc Z►J' P.O. Box 1504 LA QUINTA,. CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT . (760)777-7012 FAX (760) 777-7011 r .RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) [DATE: JANUARY 19, 2012' STATUS: FIRSTTREVIEW-& (PLAN CHECKED BY: AJ ORTEGA ,& TELEPHONE NUMBER: (760) 777=7018 ADDRESS: 80-325 VIA PESSARO DESCRIPTION: PV SOLAR SYSTEM APPLICANT: JOE VILLANUEVA PLAN CHECK #: 12-0023 This submittal has been checked for compliance with the 2010 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: < �. BUI U �, G � FA>�2TMEN,T .TA F: The following items are being returned to you for O'NOT accept any resubmittal unless ALL.df the correction: following items are included: 1- SOLAR (REDLINED) PLAN 1- SOLAR (REDLINED) PLAN 2- UNMARKED PLAN SET 1- CORRECTION LIST w/responses 1- CORRECTION LIST ✓ 2- REVISED PLAN SETS I/ 1- ASSESSORS SITENLOOR PLAN REC MAR 2 0 2012 Bl. INSTRUCTIONS TO APPLICANT: I ) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compl ancQWith a,4ggde "requirement�is �achie�ed 'Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check'. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and, - Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page 1 of 3 !'- - :Z— SECTION A - GENERAL 1) Provide.a Vicini Ma (Identifying the location of the projec ,Assessor's Parcel Num er (APN) anda' 7 e a Descri ion 'the first sheet of Plans. 2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code'5536. Resubmittals will not be accepted with signatures missing. P3)Note on Plans: "All construction shall comply with the 2010 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes and the La Quinta Municipal Code." Remove notes referencing other Codes. �` Y SECTION B — SOLAR I. General 1) Reconcile noted information shown on single line diagram. See V review redlined plan. Please provide a response for each item, either on returned redlined plan or in letter. 7' Provide on Roof Plan the proposed location of each array/string. (CRC §R106.1.1) The roof plan provided does not match approved construction drawings on file with the building department, revise. H. Circuit Requirements Ina do photovoltaic source circuit or output circuit, the maximum photovoltaic system voltage for that circuit shall be calculated as the sum of the rated open -circuit voltage of the series -connected photovoltaic modules corrected for the lowest expected ambient temperature. (CEC §690.7) The size of conductor specified on plan is not being shown as corrected per factors in Table 690.7. (31 to 23 Degrees —1.12) Please provide conductor sizing schedule showing all NEC adjustment factors. w . 2T e Circuit conductors and Overcurrent devices shall be sized to carry not less than 125% of the maximum currents as calculated in 690.8(A). (CEC §690.8(B)1) Please'see above correction for required information to be shown on plan. III. Disconnecting Means :disco eans shall be provided to disconnect all current -carrying conductors of a photovoltaic power source from all er conductors in a building or other structure. (CEC §690.13) Please provide utility accessible necting means. IV. Wiring Methods /AAll PV system wiring must be made using one of the specific instal lation/materials methods included in the (CEC §690.31, Chapter 3) Run locations not specified on single line diagram, please show locations on site plan or specify on single line diagram and revise drawings accordingly. See 1" review redlines. Where direct current photovoltaic source or output circuits of a utility -interactive inverter from a building - integrated system are run inside a building, they shall be contained in metallic raceways or enclosures. (CEC §690.31 (E)). Identify location of proposed conduits and revise drawings accordingly. Residential Plan Check Correction List (SOLAR) Page 2 of 3 City,of La Quinta.: . 3). Where the number of current-carrying conductors in a raceway exceed three.(3) the allowable ampacity of each conductor shall be reduced�as shown in Table 310.15(B)(2)(a). (CEC §310.15(B)(2)) Adjust acc rdingly, and show calculations in conductor sizing schedule.. Conduits exposed to sunlight on rooftops, where conductors or cables are installed, the adjustments shown in Table 310.15(B)(2)(c) shall be added to the outdoor temperature to determine the.applicable ambient temperature for application of the correction factors in Table 310.16. (CEC §310.15(B)(2)(c)) Adjust conductor sizes accordingly, and show calculations in conductor sizing schedule. V. Grounding o corrections apply. VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts (OProvide schedule with.the location of all required markings and labels for the proposed photovoltaic system. (CEC §690) Please update signage sheet per 2010 California Electrical Code requirements. SECTION C - STRUCTURAL 1) No corrections apply. SECTION D - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each .of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item. must be addressed prior to issuance of building permit. END CORRECTION LIST As further information is provided and reviewed; additional corrections may be required. Residential Plan Check Correction List Page 3 of 3 `F - City of La Qu i nta ' RESIDENTIAL PLAN CHECKCORRECTIONLIST SECTION A - GENERAL 1. Vicinity Map & APN can be found on PV -01 "Vicinity Map 2. Please see revised set of plans... 3. Note can be found on PV -01 "GENERAL NOTES" ' SECTION B —SOLAR' ., I. GENERAL 1. Please see revised set of plans. 2. Please see PV -02 "Plot Plan". H. • Circuit Requirements - 1. Please see PV -03 Note 2. 2. Please see PV -03 Note 2 & 7. III. Disconnecting Means - ` 1. Please see PV -02 Note 3. r N. Wiring Methods 1. Please see PV -02 Note 5 & 6. 2. Please see PV -02 Note 6. 3. No raceway shall exceed three (3) current carrying conductors, PV -02 & PV -03. ' - 4. Please see PV -03 Note 2. ` V. Grounding 1. No Corrections apply." V1. Marking; Connection to Other Sources, Storage Batteries and Systems Over 600 Volts 1. Please see PV -01 "Labels James Tourje Vintage Electric & Solar j (760)609-3431 .• ' MAR 2 0 2012 } s BY.______ Tdf 4 - 44�rw P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENT `3 78-495 CALLS TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) " DATE: APRIL2, 2012 ,STATUS: SECOND REVIEW ''PLAN CHECKED BY:.AJ ORTEGA �i (TELEPHONE NUMBER: ('7Wff7W!018� ADDRESS: 80-325 VIA PESSARO .DESCRIPTION: PV SOLAR SYSTEM .�w} APPLICANT: JOE VILLANUEVA PLAN CHECK #: 12-0023 This submittal has been checked for compliance with the 2010 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction:• '? ' 2- SOLAR (REDLINED) PLAN 1- UNMARKED PLAN SET 2- STRUCTURAL CALCULATIONS 1- CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the "•1 llowing items are included: , 2- SOLAR (REDLINED) PLAN 1- CORRECTION LIST w/responses 2- REVISED PLAN SETS ' 2- STRUCTURAL CALCULATIONS 1- ASSESSORS SITE/FLOOR PLAN — ztLQ�, V APR 1.8 201E INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or. Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business arid! Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page.1 of 3 SECTION A - GENERAL Provide a Vieinity Map (Identifying the location of the project), Assessor's Parcel Number (APN) and a Complete Legal Description on the first sheet of Plans. Please include all required information. Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a. licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code'5536. Resubmittals will not be accepted with signatures missing. 6L Note on Plans: "All construction shall comply with the 2010 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes and the La Qiinta Municipal Code." Remove notes referencing other Codes. SECTION B — SOLAR I. General Reconcile noted information shown on single line diagram. See P review redlined plan. Please provide a response for each item, either on returned redlined plan or in letter. See 1" and 2"d review plans — Array watts a xcee allowed inverter input power, revise proposed array or inverter. H. Circuit Requirements The Circuit conductors and Overcurrent devices shall be sized to carry not less than 125% of the maximum currents as calculated in 690.8(A). (CEC §690.8(B)1) Please see above correction for required information to be shown on plan. See 1St and 2nd review plans — Calculations are required to demonstrate compliance with Electrical Code derating factors for temperature, amount of conductors, etc. M. Disconnecting Means Means shall be provided to disconnect all current -carrying conddctbrs of a photovoltaic power source from all other conductors in a building or other structure. (CEC §690.13)�Please provideptility, accessible disconnecting means. Single line diagram not revised to show readily, accessible disconnect. IV. Wiring Methods ` 1) Where direct current photovoltaic source or output circuits of a utility -interactive inverter from.a building - integrated system are run inside a building, they shall be contained in metallic raceways or enclosures. (CEC §690.31 (E)). Idents location ofproposed conduits and revise drawings accordingly. Conduit type not specified o plans. �*MW wit v} G�•�,t; Where the number of current -carrying conductors in a raceway exceed three (3) the allowable ampacity of each conductor shall be reduced as shown in Table 310.15(B)(2)(a). (CEC §310.15(B)(2)) Adjust accordingly, and show calculations in conductor sizing schedule. Compliance not fully demonstrated on plans. V. Grounding *t No corrections apply. Residential Plan Check Correction List (SOLAR) Page 2 of 3 - ~ City of La Quinta VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts Provide schedule with the location of all required markings and labels for the proposed photovoltaic system.'_ (CEC §690) Please update signage sheet per 2010.California'Electrical Code requirements. Signage text not revised per specific requirements of the Electrical Code., SECTION C - STRUCTURAL . 1) Calculations'have been submitted for review and approval: At this time.we are awaiting completion of this review by our structural consultant. Applicant will notified once complete. " ' SECTION D - MISCELLANEOUS COMMENTS ^ . ' 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. - 2) Provide one -copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. r END CORRECTION LIST ' As further information is provided and reviewed, additional corrections may be required.. � s Residential Plan Check Correction List Page 3 of 3 City of La Qu i nta SOLAR PANEL WIND LOADING DESIGN: BSAE ON ASCE7-05 EXPOSURE CATEGORY: C IMPORTANCE FACTOR: 1= 1:0 BASIC WIND SPEED: V= 85 MPH TOPOGRAGHIC FACTOR: Kzt= 1.0 (FLAT AREA) ROOF SLOPE: v=0° MEAN ROOF HEIGHT: H= 11 FEET %= 1.21 COMPONET & CLADDING WIND PRESSURE (PER ASCE7-05 SECTION 6.4.2.2) NET DESIGN WIND PRESSURE P30= -19.5 PSF (FIGURE 6-3 ZONE 2) P= -23.6 PSF SOLAR PANEL SIZE: W= 38.7 IN = 3.2 FEET L= 64.8 IN = 5.4 FEET SOLAR PANEL AREA: A= (W)(L)/144 = 17.4 SF CONNECTOR SAPCE D=-- 4 FEET UPLIFT F= (P)(L)(D)/2 = -255 LBS 5/16 LEG SCREWS LOAD CAPACITY: 266 LBS/IN 2 1/2" EMBEDMENT Fs= 266X2 1/2 665 LBS >. 255 LBS USING (1) LEG BOLTS OK! SOLAR PANEL LOADING DESIGN: SOLAR PANEL WEIGHT 41.9 LBS _ SOLAR PANEL AREA 17.4 SF UNIT WEIGHT 2.4 PSF LIVE LOAD: 20 PSF > 2.4 PSF WHEN SOLAR PANEL INSTALLED NOT LIVE LOAD IN THE AREA EXISTING ROOF ADEQUATED WITH SOLAR PANEL LOADING D 1JRI,I1�9 .r rAJP WwT rim J\ uto" Uewtl £SZZ6 Va `V,LKlflb VZ lozz6 VD `OI PO Zo `OHVSS:l,La � d VIA SZ£08 'NIHV L8S817 g z w $a IaN:4Qls:4x Vn:InNVrlrlln D1111D311:l9VLtQA o z --m!E 0_ F) W W J J m V J w � Lu 0 Z_ N U N �— W�0-j�m zo LLJ C) W C)� Q (J -) EL LC) N � Q U � r } r Q LLJ Q >z Q O z QCLI C\J �°- J O 0 Q c�cLO:�i :�i E 7 Y � Lu 0 Z_ N ZZ O w N a� W�0-j�m z LLJ Lu <:° U Lo � co z %o j -Nm Tnul�- 0000000 D -(L a- n n n U 0 E ZZ O w 4� a� ZZ p O z QW 1 U OU %o 10 z �LLJ V O cn"` NQ�� o o o > > c�cLO:�i :�i E -Nm Tnul�- 0000000 D -(L a- n n n C o o60 a �O.,n , wp 0000 L rL p 2Ow�jjU zN�' NU Zww w F W OU p 3_ 0 O O O d W Q 00�="' �ZL zw OLOQ QNB K� z�wQ OU "n OzOz ;=<,< OO wp z71 z _ � QQwt�wz�m a� �-z' L J L zo 'nQ=NNZN0 UOL N=oYc ZzrOO z Z K �wKN �oNw[za Qozw U<8c � 9zo 00 OZt�� aOCo0�u0,?WaNZ O'�Z til<L� 03 �K~zuQ I L9 Ow — cf W D— Q OL> U0> O Q Ugo W O� lnl'_ Z co N Ln m_ 03 , 17 W U m O ° LO m U 'og CO w�° U Z z z � O o N r Z, O z w O o p O Q m = U m z a o o o =.� O o°C`a>U W'U a = w ED w y w z m z 0 Oamw0 rOmz_ -= g z o Cv� cn Q<W�<w �� � � O oa¢wa a z — N ch V Ln Q U U L L 4� � c U yuj d Z p W w u — — U U uO W m 5 < ZZ O w ZZ O Z ZZ O z ZZ p O z QW 1 Q OU %o 10 z �LLJ V O cn"` NQ�� C o o60 a �O.,n , wp 0000 L rL p 2Ow�jjU zN�' NU Zww w F W OU p 3_ 0 O O O d W Q 00�="' �ZL zw OLOQ QNB K� z�wQ OU "n OzOz ;=<,< OO wp z71 z _ � QQwt�wz�m a� �-z' L J L zo 'nQ=NNZN0 UOL N=oYc ZzrOO z Z K �wKN �oNw[za Qozw U<8c � 9zo 00 OZt�� aOCo0�u0,?WaNZ O'�Z til<L� 03 �K~zuQ I L9 Ow — cf W D— Q OL> U0> O Q Ugo W O� lnl'_ Z co N Ln m_ 03 , 17 W U m O ° LO m U 'og CO w�° U Z z z � O o N r Z, O z w O o p O Q m = U m z a o o o =.� O o°C`a>U W'U a = w ED w y w z m z 0 Oamw0 rOmz_ -= g z o Cv� cn Q<W�<w �� � � O oa¢wa a z — N ch V Ln Q U U L L 4� � c U yuj d Z p W w u — — a m a z wz L u D uO W m 5 < S N w W p j I Y _C .Y i I t cn Li C o o o r D ins m m m cp 1 .., ( �. • .. co t Modules Ipecifications � Global www,hyundaisolar.COM Goel Meador Electrical Characteristics Mechanical Characteristics - - - 903 mm (38,71(W) x 1545 mm (64.76') (L) X 35mm (1.38') (H) a Approx- 19.0 kg (41.911 60 ceps in series (6 X 10 matri4i 4 mm' (12AWG) cables with polarized weatherproof connectors, 4 IEC certified (UL listed), Length 1.0 m (39.4°) IP65, weatherproof, IEC certified (UL listed) • • • • 3 bypass diodes to prevent power decrease by partial shade Front: High transmission low4ron tempered glass, 3.2 mm (0.126') Encapsularl EVA Back Sheet: Weatherproof fiim Clear anodized aluminum alloy type 6063 High Quality • IEC 61215(Ed.2) and IEC 61730 by TUV Rheinland • UL listed (UL 1703), Class C Fire Rating • Output power tolerance +3/-0% • 150 9001:2000 and 150 14001:2004 Certified • Advanced Mechanical Test (5,400 Pa) Passed (IEC) /Mechanical Load Test (40 lbs fta Passed (UL) Limited Warranty • 5 years for product defect • 10 years for 90% of warranted min. power • 25 years for 80% of warranted min, power "to.". '"' us * ..�.. r Fast and Inexpensive Mounting • Delivered ready for connection • Pre-confectioned cables • IEC (UL) certified and weatherproof connectors •integrated bypass diodes la important Notice on Warranty The warranties apply only to the PV modules with Myundai Henry Industries Ca, Ltd's logo (shown bellows and product serial numher on It. 4&HYU N DAI HEAVY INDUSTRIES CO.,LTD. I Multi -crystalline Type I Nom8lal output(PmpO) w 723 225 228 230 233 235 238 voltage at Priax(Vmpp) V 30.0 30,0 30.0 30.1 30.3 30.3 30.4 Current at Pmax(impp) A 7.4 7,5 7.6 7.7 7.7 7.8 7.8 Open circuit voltage (Vac) V 36.8 37.1 37.1 37.1 37.3 37-4 37.4 Shrvt cirr-ult current (Isc) A 0.0 0,2 8.2 8.2 8.2 8.3 83 Outputtolerance % a31-0 No. of cells & conrsectlons pa 50 in series Celf type - 6• Multi -crystalline silicon Module effi(wrrcy % 13.8 13.9 14.1 14,2 14.4 14.5 14.7 Temperature coeff tient of Pmpp %X-0.43 443 -0-43 -0.43 -0.43 -0.43 -0.43 Temperature coeHklent of Vo,: %/K -032 -032 -0.32 -0.32 -0.32 -0.32 -0.32 Tempersturemeffidentofssc %IK 0.056 0.056 0.056 0.056 0,056 0.056 0.056 x All dal. STC (RaMerd Tet Cmdtiano. Ab -dam may be dantled Ad-p1m, mdse. I Mono -crystalline Type I Nominal output(Pmpp) 23 238 _140 243 ag 250 w 235 238 240 243 -XI J® 248 250 Voltage at Pmax (Vmpp) V 29.8 29.8 30.1 30.1 30.3 30.3 30.5 (urrent at Pmax (Impp) A 7.9 8.0 8.0 8.1 8.1 8.2 8.2 Open droit voltage (voc) V 37.0 37.0 37.3 37.3 37.4 37.5 37.5 Short cauit current (Isc) A 8A &5 8.5 8,6 8.6 8.7 8.7 Outputtolerance % ♦31-0 Noof cells &connections pis 60 in series C4atype - P Mono -crystalline silicon Module efficiency % 14.5 14.7 14.8 15.0 15.2 15.3 15.3 Temperaaae coefficient of Pmpp WK -0.44 -0.44 -0.44 -0.44 -0.44 -0.44 -0.44 Temperaturc coefficient of V. 141K -0.34 -0.34 -0.34 -u.34 -u.34 -0.34 -O.34 Temperature coefficient of Isc %8C 0,052 0.052 0,052 0.052 0.052 0.052 0,052 :•. All delict STC (SmMmd Ten Co^®Jim At -data mq br° n,io, Mur PI^r I Module Diagram I Yun4rmm'xh) I I-V Curves I P 11 s �.tl0alw)fY r,OertmA� 4 arrw%w (4M'Etler f!YlKida raaaawac 1+e•h mp ler T i%al aaao int Pi 9P'%9n g C 'rI W139'I tq trLngan%•x2A1NOEf R c coon 1tn srcraecc .arca xan -o I Installation Safety Guide I Only qualified personnel should install or perform maintenance. Be aware of dangerous high DC voltage. Do not damage or scratch the rear surface of the module, Do not handle or install modules when they are wet. +r,n IA7 ad Miss-4roae,r ppwaP[arwp.PY gnprA lep.aK M•eehlrwq.NK ^ -�ea1p CAMq.NK anwµl wwrM _.1aa ssae Ca M•-aK 46'C t 2 -40 85 C DC 1,000 V (IEC) DC 600 V (UL) 15 A cr- or, Roject Number: Dem: 03/09/12 NTS Sane, TOm: Module Drawbp Number. PV -05 Inverter Specifications SUNNY BOY 500OUS / 6000US / 700OUS / 8000US Pi ethnical Data • HigWv CEC eflioimcy is ds class • S"".l•clmmcs.-k-nt d +_ Ideal for residerrkal or commercial • tw gmt d loodbreri rated Opkcool. Pplic.6- lockable DC disconmtet sw8ch • Comiambensiv. SMA • Sunny Tovror compaibi• • Integrated fused sones skiing comtrrunicotons and data 10 year standard warranty n �� combin.r cdl.chon oprions • UL 1741/IEEE-1547 compliant V SUNNY BOY 5000US/6000US/7000US / 8000US The best in their class Our US series inverters utilize our proven technology and are designed specifically to meet IEEE -1547 requirements. Sunny Boy 6000US, Sunny Boy 7000US and Sunny Boy 6000US ore also compatible with the Sunny Tower. Increased efficiency means better performance and shorter payback periods. pJl four models are held -configurable for positive ground systems making them more versatile than ever. Throughout the world, Sunny Boy is the benchmark for PV inverter performance and reliability. Recomm.nd.d Morimum PV Poway fModuls STC) DC Mauna. Vokage Peak Power TrockkV Vokoge OC M..imum input Current Number of Fused Skmg Inpws PV Start V.1toge AC Nominal Power AC Mo..- Oviput Power AC M.A- Ougwt Cvrrml (0 208, 240, 277 Vl AC Nominal Valmge Range AC h" --y; --I / rang. Power Factor (Nominal( Peak Ir..W EBidency CEC Weighed Effidency Dimenswm. W . H . D in inches Weight / Shipping Weight Ambi -t Temperotur. Range P. -* ---.p'- Wight Topology Goofing Conc.pt M-wmg tocol- i -d- / oureoor (NEMA 3Rf LCD Display Corne+miconon RSA83/...4n Wwrar.y'. l0 years / 15 years / 20 yaaa Complh- IEEE -929, IEEE -1517, 11L 1741, UL 1998, ECC Pan 15 A& 8 5pacifk06ens In nn,o,v,l mr Al 1,101 E. US in -t- drip w8h gray lids. Efficiency Curves SSSOOOW SO 60DOUS S87000US so SODOM 6250 W 7500W 8750 W 10000 W 600 V 600V 600 V 600 V 750-ABOV 250-480V 250-480V 300-4804 21 A 25 A 30 A 30A 30",wf, dx 20A 3(1-wx), A. 20A 3(imerbr), A. 20 A 3ffineneri, Ax 20A (DC disconnect) IDC dbcamaA (DCd7scomwc1) (DC discomectl 300V 300V 300 V 365 V 5000 W 6000 W 7000 W 8000 W 5000 W 6000 W 7000 W 6000W 24 A, 21 A, 18A 29 A. 25 A, 22 A 34A, 29 A. 25 A N/A, 32 A, 29 A 183-229 V0208Y 183-229 V0208V 483-229VO208V N/A 0208V 211 - 264 V 0 24O V 211 - 264 V 0 2AO V 211. 264 V 0 240 V 211 _ 264 Y 0 240 V 2"-305V277V241-305 V277V 244-305VO 277Y 24-305VO277V 60H./59.3 - 60.5 Hs 60 Hz / 59.3 - 60.5 Hz 60 H. / 593 - 60.5 Ha 60 H. / 59.3 - 60.5 Ha 099 0.99 099 099 96.8% 970% 971'1 96.5% 95.5%6208V 95.5%0208V 95.5%02084 N/A 0200V 95.5%0?AD V 95-5%02AOY 96.0%0240V 96.0%0240V 95.5%0277V 96.0%0277V 96.0%4277V 96.0%0277V 18.4 x24.1.9.5 18.4 x24.1 x9.5 18.4 .24.1x9.5 ICA .24.1 .9.5. 141 lbs/ IAS lb, 14116,,/14B W. 14116,,/ 14816. 14887,,/ 1521sn -13 to 113'F -13ta113'F -137E+113'F -13 to 113-F 0.1 W 0.1 W 0.1 W 0.1 W Lowfregencytransformer, Lawheq... cykmrdormer, low frequency nandornrer, low Freguenry Imnsfarmer, In* tlnawow rruo 34no wo kw ilnowave Iruo sinowoso OptiCoopv, OpticoolTM, Optic -11-! Optic -11. forced actio. -.69 forced act - -.line forced alive cooling for -d acl- coolmg ./. 0/0 0/6 0/6 • • • • • • • . Inclvdod O Opticnal Tel. +1 916 625 0870 Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC W Z �kn ASN f�W�V tr zNa OM aW V I� Eli* W � V WHO 4 � Dr by Frank Alonso aw x te: Pralsa Nu~ oae: 03/09/12 S .N: NTS sne.7 nue: Inverter D..., Num.•r' PV -06 ,,,e x•a sma P- NA swro eon ran Tel. +1 916 625 0870 Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC W Z �kn ASN f�W�V tr zNa OM aW V I� Eli* W � V WHO 4 � Dr by Frank Alonso aw x te: Pralsa Nu~ oae: 03/09/12 S .N: NTS sne.7 nue: Inverter D..., Num.•r' PV -06 Villanueva Residence . La Ouinta • 80325 Via Pessam Inverter String Sizing Configuration Evaluation of design Vintage Electric 48587 Marin Ct. Project name: Villanueva Residence Project number: Indio, CA 92201 Project file: Tel.: (760) 834-2204 Part project 1 Location: United States of America / La Quinta Ambient temperature: Record Low Temperature: 13.00 *r Average High Temperature: 107.00 IF Record High Temperature: 123.40 IF Fax: E -Mail: james@vintageelectric.us 1 x SS BOODUS — 240VAC Intemet: www.vintageelectric.us PV peak power: 10.42 kWp Total number of PV modules: 42 Project name: Villanueva Residence Location: United States of America / La Number of Inverters: 1 Project number. Max. DC power: 8.60 kW Projekt file: Grid voltage: 1240 V Max. AC power: 7.68 kW Grid voltage: 240 V 6"6a"_ Nominal power ratio: 83% Q SB 8000US - 240VAC 42 x Hyundai HiS-S248MG (US) (PV -array 1) Azimuth angle: 01, Inclination: 01, Mounting type: Roof, PV peak power: 10.42 kWp 111 x SB 8000US - 240VAC Total number of PV modules: 42 Energy usability factor: 99.6% PV peak power: 10.42 kWp Performance ratio (approx.)'! 83.2 % Number of Inverters: 1 Spec. energy yield (approx.)*: 1432 kWh/kWp Nominal AC power: 7.68 kW Line losses (in % of PV energy): --- AC active power: 7.68 kW Unbalanced load: 7.68 kVA Active power, ratio: 73.7% Self -consumption: --- Annual energy yield (approx.)*: 14912.60 kWh Seff-consumption quota: --- Max. PV voltage: 589 V Signature *Important: The yield values displayed are estimates. They are determined mathematically. SMA solar Technology AG accepts no responsibility for the real yield value which can deviate from the yield values displayed dere. Reasons for deviations are various outside conditions, such as soling of the PV Modules or fluctuations to the efficiency of the PV modules. O Max. DC current: Input A: PV -array 1 42 x Hyundai HiS-5248MG (US), Azimuth angle: 01, Inclination: 01, Mounting type: Roof PV/Inverter compatible Input A: Number of strings: 3 PV modules per string: 14 Peak power (input): 10.42 kWp Typical PV voltage: 352 V 0 Min. PV voltage: 325 V 0 Min. DC voltage (Grid voltage 240 V): 300 V Max. PV voltage: 589 V 0 Max. DC voltage (PV): 600 V Max. current of PV array: 24.6 A O Max. DC current: 30.0 A PV/Inverter compatible i� � U N Draw^ w Frank Alonso cn� ey: P,oixt N...,: D.. 03/09/12 s^,m NTS s1e T 1 Inverter Config Dewing Number'. PV -07