12-0023 (SOL)P.O. BOXf 1504'
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description:
Property Zoning:
Application valuation:
Applicant:
LOA 104C Mr
12-00000023
80325 VIA PESSARO '
777-180-012- - -
SOLAR
LOW DENSITY RESIDENTIAL
52000
t
4
ul�cv
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT ,
Owner: ,
VILLANUEVA FAMILY
3807 42ND AVE NE
' SEATTLE, WA 98105
Architect or Engineer:
'
Contractor:
VINTAGE ELECTRIC
48587 MARIN COURT
INDIO, CA 92201
(760)775-0135
Lia_ No.: 481352
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/03/12
- - - - - - - - - - - - - - - - - - - - - - - - - -'- - - - - - - - - - - - - - - _ - _- -- -
- - - - - - - - - -'- - - - - - - - - - - --- - - _ - - - - - - - - - - - - - - - - - - - ,
- LICENSED CONTRACTOR'S DECLARATION;
--
- - WORKER'S COMPENSATION. DECLARATION -
I hereby affirm underpenalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License Clas : 10 C46 License No.: 481352 ,
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
Date: f IContractor: V I ` c�'`�� �t �- _
issued.
-_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
• - -
Code, for the performance of the work for which this permit is issued.. My workers' compensation
OWNER -BUILDER DECLARATION-
insurance carrier and policy number are:
rCarrier
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
STATE FUND - - - Policy Number 90059i4-12
following reason (Sec. 7031.5, Business and Professions Code: 'Any city or county that requires a permit to
-- _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
person in any manner so as to become subject to the workers' compensation laws of California, -
- permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State-
and agree that, if 1 should become subject to the workers' compensation provisionsof Section ,
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
3700 of the Labor Cyde, I shall forthwith c mply ith•those provisions.
/ ,•V/'I ..(L�`Lt,� F wl
- any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500) -
_
Date: l Z Applicant: - - o — �•' 0""' J
(_) I, as owner of the property, or my employees with wages as their sole compensation,' will do the work, and
'
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
- Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES•UP TO ONE HUNDRED THOUSAND
and who does the work himself or herself through his or her own employees, provided that the
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. -,..+..
' - one year of completion, the owner -builder will have the burden of proving that he or she did not build or
- -
.. improve for the purpose of sale.).
APPLICANT ACKNOWLEDGEMENT •'
(_) I, as owner of the property, am exclusively contracting withlicensed contractors to construct the project (Sec.
IMPORTANT Application is,hereby made to the Director of Building and Safety for a permit subject to the
• 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
conditions and restrictions set forth on this application.
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
1. Each person upon whose behalf this application is made, each person at whose request and for
pursuant to the Contractors' State License Law.)•
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
(_) I. am exempt under Sec. , BAP.C. for this reason
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
-
of La Quinta, its officers, agents and employees for any, act or omission related to the work being
- -
performed under or following issuance of this permit.
-. Date: Owner:
2. Any permit issued as a result of this application becomes null and void if work is not commenced
-
within 180 days from date of issuance of such permit, or cessationof work for 180 days will subject '.
• CONSTRUCTION LENDING AGENCY
permit to cancellation.
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the -
I certify that I have read this application and state that the above information is correct. I agree to comply with' all,
work for which this permit is issued (Sec. 3097, Civ. C.)•
city and county ordinances and state laws relating to building construction, and hereby authorize representatives -
of this co my to enter upon the above-mentioned property for'nb o -
spection pu.ti
• Lender's Name: -
-
�' I
s
-
DateSignature (Applicant or Agent): -
Lender's Address:.
-
LQPERMIT
Application Number .. . . . . 12-00000023
'
i Permit SOLAR PERMIT
Additional desc
'
Permit Fee- 22.50 Plan Check - Fee
5.63
Issue Date. Valuation
52000
Expiration Date 10/30/12
' 'Qty Unit Charge Per
Extension
BASE FEE
a 15.00 - r
1.00 4.5000 EA SOLAR COLLECTOR.< 1000
4.50
1.00. 3.000O+EA SOLAR EQUIP MISCELLANEOUS-
3.00
-------_-------------------------------------------------------------------
,
Permit .. ELEC-MISCELLANEOUS
•.
r. Additional desc
..• ,
r . •`Permit Fee . . . 22.50 .Plan Check Fee
5.63 -
Issue Date Valuation
0
k.
_ Expiration Date 10/30/12
'
fQty Unit Charge" Per
_.Extension `•"
BASE FEE ,.,
15.00 t'"•
- 1.00 -7.5000 EA' ELEC PWR APP >1 TO '<=10 '
L
.-7.50 �: a
___ _______4
-.-____ __ t _a_ �- j__77
Special Notes and COmmentS•
_ � ___
10.4kW SOLAR ARRAY - (42)..248W HYUNDAI `
PANELS W/ (1) 8,000W SMA AMERICA
"t '
INVERTER (.714SFj 2010• CALIFORNIA
ELECTRICAL CODE.,
May 2,-2012 9:58:38 AM AORTEGA
-----------------`----------------------------------t--------
- j Other Fees BLDG S.TDS:ADMIN (SB1473)
-- ---- -r-- --
3.00'
+ •` - Fee. summary Charged r;. Paid Credtedf:
Due �, f
------------ -`------------ - ---- _-- _, -----"F'
__---------
----
-Permit
Permit Fee Total � 45.00• '. 00 '00
45 00 , y
.
' Plan Check Total 11 26` .00 .•00
' 11.26 _
' Other Fee Total' 3..00 .00 00•
3.00
.. _ Grand Total 59.26 .00 .00
59,26
LQPERMIT
Bin #
Gey of, la Quinta
Building 8t Safety Division
P.O. Box 1504,78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
BuildingPermit
Application and Tracking Sheet
Permit #
Z�
` /� p
Project Address: 3 2S �1 l A
Owner's Name:
A. P. Number:
Address: �o32•S �/�o. IPtSSo rCry
Legal Description:
City; ST, Zip: tA q 2253
i
Contractor, �1��0�9� �lt�tl✓► � 'o.r'
`4 �
Telephone: .�, : " ''.Z^'"• :s.::��'�,..s
Address:t`��r\;',
Project Description: 2, Sp�� IPV
City, ST, Zip: 1 v\ A i O VT Z O \
��v1s-E-a��
a ergs t ca'+ Z-V-% V' Ooh SSC
Telephone: "1 too 'O 13 S
State Lie. City Lie. #; ...h
Arch., Engr., Designer:
�L� V
�N/v
�� J .. I .sp�
Address:
City, ST, Zip:
Telephone:
P
�, r n>c .'
� • .,,, ,,. ;.:z<:� •�::,.,,,
W ),. RL::S::�:�r..fo.'•:>:a ••y
.sProJect
Construction Type: Occupancy: .
an
State Lie. #:
type (circle one): d-ID Add'n Alter Repair Demo
Name of Contact Person: .J A VV\ V l 1�) Y•
U ,
Sq. Ft.:
# Stories: #Units:
Telephone # of Contact Person: 'I Iwo \0 0 9 .Sq 3
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACIUNG
PERMIT FEES
Plan Sets
p�
Plan Check submitted IN
Item Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit �—
Truss Cales.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked upop Ity
Construction S. 1-vv�2.
Flood plain plan
Plans resubmitted ,ZDn
Mechanical .-.
Grading plan
2'" Review, ready foco rectio issue
ElectricalO Ime
Subcontactor List
Called Contact Person
Plumbing �.
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Q
Plans resubmitted 0
Grading ' ..._
IN HOUSE:-
m'd Review, ready for iorrectio meso N
Developer Impact Fee
Planning Approval
Called Contact Person S
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
S� V
School Fees
Total Permit Fees
k 11 4� tion • �Q. 1KL.
5 ti .�ti� tom.
ISD fey. 4Wc Z►J'
P.O. Box 1504
LA QUINTA,. CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT .
(760)777-7012
FAX (760) 777-7011
r
.RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR)
[DATE: JANUARY 19, 2012'
STATUS: FIRSTTREVIEW-&
(PLAN CHECKED BY: AJ ORTEGA ,&
TELEPHONE NUMBER: (760) 777=7018
ADDRESS: 80-325 VIA PESSARO
DESCRIPTION: PV SOLAR SYSTEM
APPLICANT: JOE VILLANUEVA
PLAN CHECK #: 12-0023
This submittal has been checked for compliance with the 2010 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT: < �. BUI U �, G � FA>�2TMEN,T .TA F:
The following items are being returned to you for O'NOT accept any resubmittal unless ALL.df the
correction: following items are included:
1- SOLAR (REDLINED) PLAN 1- SOLAR (REDLINED) PLAN
2- UNMARKED PLAN SET 1- CORRECTION LIST w/responses
1- CORRECTION LIST ✓ 2- REVISED PLAN SETS
I/ 1- ASSESSORS SITENLOOR PLAN
REC
MAR 2 0 2012
Bl.
INSTRUCTIONS TO APPLICANT:
I ) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compl ancQWith a,4ggde "requirement�is �achie�ed 'Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check'.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and, -
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List (SOLAR) Page 1 of 3
!'- - :Z—
SECTION A - GENERAL
1) Provide.a Vicini Ma (Identifying the location of the projec ,Assessor's Parcel Num er (APN) anda'
7 e a Descri ion 'the first sheet of Plans.
2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code'5536. Resubmittals will not be accepted with signatures missing.
P3)Note on Plans: "All construction shall comply with the 2010 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes and the La Quinta Municipal Code." Remove notes
referencing other Codes. �` Y
SECTION B — SOLAR
I. General
1) Reconcile noted information shown on single line diagram. See V review redlined plan. Please provide a
response for each item, either on returned redlined plan or in letter.
7' Provide on Roof Plan the proposed location of each array/string. (CRC §R106.1.1) The roof plan provided
does not match approved construction drawings on file with the building department, revise.
H. Circuit Requirements
Ina do photovoltaic source circuit or output circuit, the maximum photovoltaic system voltage for that circuit
shall be calculated as the sum of the rated open -circuit voltage of the series -connected photovoltaic modules
corrected for the lowest expected ambient temperature. (CEC §690.7) The size of conductor specified on
plan is not being shown as corrected per factors in Table 690.7. (31 to 23 Degrees —1.12) Please provide
conductor sizing schedule showing all NEC adjustment factors. w .
2T e Circuit conductors and Overcurrent devices shall be sized to carry not less than 125% of the maximum
currents as calculated in 690.8(A). (CEC §690.8(B)1) Please'see above correction for required information
to be shown on plan.
III. Disconnecting Means
:disco
eans shall be provided to disconnect all current -carrying conductors of a photovoltaic power source from all
er conductors in a building or other structure. (CEC §690.13) Please provide utility accessible
necting means.
IV. Wiring Methods
/AAll PV system wiring must be made using one of the specific instal lation/materials methods included in the
(CEC §690.31, Chapter 3) Run locations not specified on single line diagram, please show locations on
site plan or specify on single line diagram and revise drawings accordingly. See 1" review redlines.
Where direct current photovoltaic source or output circuits of a utility -interactive inverter from a building -
integrated system are run inside a building, they shall be contained in metallic raceways or enclosures. (CEC
§690.31 (E)). Identify location of proposed conduits and revise drawings accordingly.
Residential Plan Check Correction List (SOLAR) Page 2 of 3
City,of La Quinta.: .
3). Where the number of current-carrying conductors in a raceway exceed three.(3) the allowable ampacity of
each conductor shall be reduced�as shown in Table 310.15(B)(2)(a). (CEC §310.15(B)(2)) Adjust
acc rdingly, and show calculations in conductor sizing schedule..
Conduits exposed to sunlight on rooftops, where conductors or cables are installed, the adjustments shown in
Table 310.15(B)(2)(c) shall be added to the outdoor temperature to determine the.applicable ambient
temperature for application of the correction factors in Table 310.16. (CEC §310.15(B)(2)(c)) Adjust
conductor sizes accordingly, and show calculations in conductor sizing schedule.
V. Grounding
o corrections apply.
VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts
(OProvide schedule with.the location of all required markings and labels for the proposed photovoltaic system.
(CEC §690) Please update signage sheet per 2010 California Electrical Code requirements.
SECTION C - STRUCTURAL
1) No corrections apply.
SECTION D - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
2) Provide one copy each .of the Site Plan and Floor Plan for the County Assessor's office. While not required
for resubmittal, this administrative item. must be addressed prior to issuance of building permit.
END CORRECTION LIST
As further information is provided and reviewed; additional corrections may be required.
Residential Plan Check Correction List Page 3 of 3
`F
- City of La Qu i nta '
RESIDENTIAL PLAN CHECKCORRECTIONLIST
SECTION A - GENERAL
1. Vicinity Map & APN can be found on PV -01 "Vicinity Map
2. Please see revised set of plans...
3. Note can be found on PV -01 "GENERAL NOTES" '
SECTION B —SOLAR'
.,
I. GENERAL
1. Please see revised set of plans.
2. Please see PV -02 "Plot Plan".
H. • Circuit Requirements -
1. Please see PV -03 Note 2.
2. Please see PV -03 Note 2 & 7.
III. Disconnecting Means -
` 1. Please see PV -02 Note 3. r
N. Wiring Methods
1. Please see PV -02 Note 5 & 6.
2. Please see PV -02 Note 6.
3. No raceway shall exceed three (3) current carrying conductors, PV -02 & PV -03. '
- 4. Please see PV -03 Note 2. `
V. Grounding
1. No Corrections apply."
V1. Marking; Connection to Other Sources, Storage Batteries and Systems Over 600 Volts
1. Please see PV -01 "Labels
James Tourje
Vintage Electric & Solar j
(760)609-3431 .• '
MAR 2 0 2012
} s BY.______
Tdf 4 - 44�rw
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENT
`3
78-495 CALLS TAMPICO (760) 777-7012
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) "
DATE: APRIL2, 2012
,STATUS: SECOND REVIEW
''PLAN CHECKED BY:.AJ ORTEGA �i
(TELEPHONE NUMBER: ('7Wff7W!018�
ADDRESS: 80-325 VIA PESSARO
.DESCRIPTION: PV SOLAR SYSTEM .�w}
APPLICANT: JOE VILLANUEVA
PLAN CHECK #: 12-0023
This submittal has been checked for compliance with the 2010 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT:
The following items are being returned to you for
correction:• '? '
2- SOLAR (REDLINED) PLAN
1- UNMARKED PLAN SET
2- STRUCTURAL CALCULATIONS
1- CORRECTION LIST
BUILDING DEPARTMENT STAFF:
DO NOT accept any resubmittal unless ALL of the
"•1 llowing items are included: ,
2- SOLAR (REDLINED) PLAN
1- CORRECTION LIST w/responses
2- REVISED PLAN SETS '
2- STRUCTURAL CALCULATIONS
1- ASSESSORS SITE/FLOOR PLAN — ztLQ�,
V
APR 1.8 201E
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or.
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business arid!
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List (SOLAR) Page.1 of 3
SECTION A - GENERAL
Provide a Vieinity Map (Identifying the location of the project), Assessor's Parcel Number (APN) and a
Complete Legal Description on the first sheet of Plans. Please include all required information.
Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a. licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code'5536. Resubmittals will not be accepted with signatures missing.
6L Note on Plans: "All construction shall comply with the 2010 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes and the La Qiinta Municipal Code." Remove notes
referencing other Codes.
SECTION B — SOLAR
I. General
Reconcile noted information shown on single line diagram. See P review redlined plan. Please provide a
response for each item, either on returned redlined plan or in letter. See 1" and 2"d review plans — Array
watts a xcee allowed inverter input power, revise proposed array or inverter.
H. Circuit Requirements
The Circuit conductors and Overcurrent devices shall be sized to carry not less than 125% of the maximum
currents as calculated in 690.8(A). (CEC §690.8(B)1) Please see above correction for required information to
be shown on plan. See 1St and 2nd review plans — Calculations are required to demonstrate compliance
with Electrical Code derating factors for temperature, amount of conductors, etc.
M. Disconnecting Means
Means shall be provided to disconnect all current -carrying conddctbrs of a photovoltaic power source from all
other conductors in a building or other structure. (CEC §690.13)�Please provideptility, accessible
disconnecting means. Single line diagram not revised to show readily, accessible disconnect.
IV. Wiring Methods `
1) Where direct current photovoltaic source or output circuits of a utility -interactive inverter from.a building -
integrated system are run inside a building, they shall be contained in metallic raceways or enclosures. (CEC
§690.31 (E)). Idents location ofproposed conduits and revise drawings accordingly. Conduit type not
specified o plans.
�*MW wit v} G�•�,t;
Where the number of current -carrying conductors in a raceway exceed three (3) the allowable ampacity of
each conductor shall be reduced as shown in Table 310.15(B)(2)(a). (CEC §310.15(B)(2)) Adjust accordingly,
and show calculations in conductor sizing schedule. Compliance not fully demonstrated on plans.
V. Grounding
*t No corrections apply.
Residential Plan Check Correction List (SOLAR) Page 2 of 3
- ~ City of La Quinta
VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts
Provide schedule with the location of all required markings and labels for the proposed photovoltaic system.'_
(CEC §690) Please update signage sheet per 2010.California'Electrical Code requirements. Signage text not
revised per specific requirements of the Electrical Code.,
SECTION C - STRUCTURAL .
1) Calculations'have been submitted for review and approval: At this time.we are awaiting completion of this
review by our structural consultant. Applicant will notified once complete. " '
SECTION D - MISCELLANEOUS COMMENTS ^ . '
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
-
2) Provide one -copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required
for resubmittal, this administrative item must be addressed prior to issuance of building permit. r
END CORRECTION LIST '
As further information is provided and reviewed, additional corrections may be required..
� s
Residential Plan Check Correction List Page 3 of 3
City of La Qu i nta
SOLAR
PANEL WIND LOADING DESIGN:
BSAE ON ASCE7-05
EXPOSURE CATEGORY:
C
IMPORTANCE FACTOR:
1=
1:0
BASIC WIND SPEED:
V=
85 MPH
TOPOGRAGHIC FACTOR:
Kzt=
1.0 (FLAT AREA)
ROOF SLOPE:
v=0°
MEAN ROOF HEIGHT:
H=
11 FEET
%= 1.21
COMPONET & CLADDING
WIND PRESSURE
(PER ASCE7-05 SECTION 6.4.2.2)
NET DESIGN WIND PRESSURE P30=
-19.5 PSF
(FIGURE 6-3 ZONE 2)
P=
-23.6 PSF
SOLAR PANEL SIZE:
W=
38.7 IN =
3.2 FEET
L=
64.8 IN =
5.4 FEET
SOLAR PANEL AREA:
A=
(W)(L)/144 =
17.4 SF
CONNECTOR SAPCE
D=--
4 FEET
UPLIFT F=
(P)(L)(D)/2 =
-255 LBS
5/16 LEG SCREWS LOAD CAPACITY:
266 LBS/IN
2 1/2" EMBEDMENT
Fs= 266X2 1/2
665 LBS >.
255 LBS
USING (1) LEG BOLTS OK!
SOLAR PANEL LOADING DESIGN:
SOLAR PANEL WEIGHT 41.9 LBS _
SOLAR PANEL AREA 17.4 SF
UNIT WEIGHT 2.4 PSF
LIVE LOAD: 20 PSF > 2.4 PSF
WHEN SOLAR PANEL INSTALLED NOT LIVE LOAD IN THE AREA
EXISTING ROOF ADEQUATED WITH SOLAR PANEL LOADING
D
1JRI,I1�9
.r
rAJP
WwT rim J\ uto"
Uewtl
£SZZ6 Va `V,LKlflb VZ lozz6 VD `OI PO
Zo
`OHVSS:l,La �
d VIA SZ£08 'NIHV L8S817 g z w $a
IaN:4Qls:4x Vn:InNVrlrlln D1111D311:l9VLtQA o
z --m!E 0_
F)
W
W
J
J
m
V J
w
� Lu
0
Z_ N
U
N
�—
W�0-j�m
zo
LLJ
C)
W
C)�
Q
(J -)
EL
LC)
N
�
Q
U
�
r
}
r
Q
LLJ
Q
>z
Q
O
z
QCLI
C\J
�°-
J
O
0
Q
c�cLO:�i
:�i
E
7
Y
� Lu
0
Z_ N
ZZ
O w
N
a�
W�0-j�m
z
LLJ Lu
<:°
U
Lo
� co z
%o
j
-Nm Tnul�-
0000000
D -(L a- n n n
U
0
E
ZZ
O w
4�
a�
ZZ p
O
z
QW
1
U
OU
%o
10
z
�LLJ
V
O
cn"`
NQ��
o o
o
> >
c�cLO:�i
:�i
E
-Nm Tnul�-
0000000
D -(L a- n n n
C
o
o60 a �O.,n , wp 0000
L rL p 2Ow�jjU zN�' NU Zww w
F W OU p 3_ 0 O O O d W Q
00�="'
�ZL zw OLOQ QNB K� z�wQ
OU
"n
OzOz ;=<,< OO wp z71
z
_ � QQwt�wz�m a� �-z'
L J L
zo 'nQ=NNZN0 UOL N=oYc ZzrOO
z Z K �wKN
�oNw[za Qozw U<8c � 9zo 00
OZt�� aOCo0�u0,?WaNZ O'�Z til<L�
03 �K~zuQ
I
L9
Ow
— cf
W
D— Q
OL>
U0>
O
Q
Ugo
W
O�
lnl'_ Z
co
N
Ln
m_
03
,
17
W
U
m O °
LO m U
'og
CO
w�°
U
Z
z
z � O o
N r
Z, O
z w O o p
O Q m
= U m z
a o o o =.� O
o°C`a>U W'U
a = w
ED w y w z m z 0
Oamw0
rOmz_ -= g
z o Cv�
cn
Q<W�<w ��
� � O
oa¢wa a
z — N ch V Ln Q
U
U L
L 4�
� c U yuj
d Z p W
w u —
—
U
U
uO
W
m
5
<
ZZ
O w
ZZ
O Z
ZZ
O z
ZZ p
O
z
QW
1
Q
OU
%o
10
z
�LLJ
V
O
cn"`
NQ��
C
o
o60 a �O.,n , wp 0000
L rL p 2Ow�jjU zN�' NU Zww w
F W OU p 3_ 0 O O O d W Q
00�="'
�ZL zw OLOQ QNB K� z�wQ
OU
"n
OzOz ;=<,< OO wp z71
z
_ � QQwt�wz�m a� �-z'
L J L
zo 'nQ=NNZN0 UOL N=oYc ZzrOO
z Z K �wKN
�oNw[za Qozw U<8c � 9zo 00
OZt�� aOCo0�u0,?WaNZ O'�Z til<L�
03 �K~zuQ
I
L9
Ow
— cf
W
D— Q
OL>
U0>
O
Q
Ugo
W
O�
lnl'_ Z
co
N
Ln
m_
03
,
17
W
U
m O °
LO m U
'og
CO
w�°
U
Z
z
z � O o
N r
Z, O
z w O o p
O Q m
= U m z
a o o o =.� O
o°C`a>U W'U
a = w
ED w y w z m z 0
Oamw0
rOmz_ -= g
z o Cv�
cn
Q<W�<w ��
� � O
oa¢wa a
z — N ch V Ln Q
U
U L
L 4�
� c U yuj
d Z p W
w u —
—
a
m a
z
wz
L
u D
uO
W
m
5
<
S
N w
W p
j
I
Y
_C
.Y
i
I
t
cn
Li
C
o
o
o
r
D
ins
m
m
m
cp
1 ..,
(
�. • .. co
t
Modules Ipecifications
�
Global
www,hyundaisolar.COM Goel Meador Electrical Characteristics
Mechanical Characteristics -
- - 903 mm (38,71(W) x 1545 mm (64.76') (L) X 35mm (1.38') (H)
a
Approx- 19.0 kg (41.911
60 ceps in series (6 X 10 matri4i
4 mm' (12AWG) cables with polarized weatherproof connectors,
4 IEC certified (UL listed), Length 1.0 m (39.4°)
IP65, weatherproof, IEC certified (UL listed)
• • • • 3 bypass diodes to prevent power decrease by partial shade
Front: High transmission low4ron tempered glass, 3.2 mm (0.126')
Encapsularl EVA Back Sheet: Weatherproof fiim
Clear anodized aluminum alloy type 6063
High Quality
• IEC 61215(Ed.2) and IEC 61730 by TUV Rheinland
• UL listed (UL 1703), Class C Fire Rating
• Output power tolerance +3/-0%
• 150 9001:2000 and 150 14001:2004 Certified
• Advanced Mechanical Test (5,400 Pa) Passed (IEC)
/Mechanical Load Test (40 lbs fta Passed (UL)
Limited Warranty
• 5 years for product defect
• 10 years for 90% of warranted min. power
• 25 years for 80% of warranted min, power
"to.". '"' us * ..�.. r
Fast and Inexpensive Mounting
• Delivered ready for connection
• Pre-confectioned cables
• IEC (UL) certified and weatherproof connectors
•integrated bypass diodes
la important Notice on Warranty
The warranties apply only to the PV modules with Myundai Henry Industries
Ca, Ltd's logo (shown bellows and product serial numher on It.
4&HYU N DAI
HEAVY INDUSTRIES CO.,LTD.
I Multi -crystalline Type I
Nom8lal output(PmpO)
w
723
225
228
230
233
235
238
voltage at Priax(Vmpp)
V
30.0
30,0
30.0
30.1
30.3
30.3
30.4
Current at Pmax(impp)
A
7.4
7,5
7.6
7.7
7.7
7.8
7.8
Open circuit voltage (Vac)
V
36.8
37.1
37.1
37.1
37.3
37-4
37.4
Shrvt cirr-ult current (Isc)
A
0.0
0,2
8.2
8.2
8.2
8.3
83
Outputtolerance
%
a31-0
No. of cells & conrsectlons
pa
50 in series
Celf type
-
6• Multi -crystalline
silicon
Module effi(wrrcy
%
13.8
13.9
14.1
14,2
14.4
14.5
14.7
Temperature coeff tient of Pmpp
%X-0.43
443
-0-43
-0.43
-0.43
-0.43
-0.43
Temperature coeHklent of Vo,:
%/K
-032
-032
-0.32
-0.32
-0.32
-0.32
-0.32
Tempersturemeffidentofssc
%IK
0.056
0.056
0.056
0.056
0,056
0.056
0.056
x All dal. STC (RaMerd Tet Cmdtiano. Ab -dam may be dantled Ad-p1m, mdse.
I Mono -crystalline Type I
Nominal output(Pmpp)
23
238
_140
243
ag
250
w
235
238
240
243
-XI
J®
248
250
Voltage at Pmax (Vmpp)
V
29.8
29.8
30.1
30.1
30.3
30.3
30.5
(urrent at Pmax (Impp)
A
7.9
8.0
8.0
8.1
8.1
8.2
8.2
Open droit voltage (voc)
V
37.0
37.0
37.3
37.3
37.4
37.5
37.5
Short cauit current (Isc)
A
8A
&5
8.5
8,6
8.6
8.7
8.7
Outputtolerance
%
♦31-0
Noof cells &connections
pis
60 in series
C4atype
-
P Mono
-crystalline
silicon
Module efficiency
%
14.5
14.7
14.8
15.0
15.2
15.3
15.3
Temperaaae coefficient of Pmpp
WK
-0.44
-0.44
-0.44
-0.44
-0.44
-0.44
-0.44
Temperaturc coefficient of V.
141K
-0.34
-0.34
-0.34
-u.34
-u.34
-0.34
-O.34
Temperature coefficient of Isc
%8C
0,052
0.052
0,052
0.052
0.052
0.052
0,052
:•. All delict STC (SmMmd Ten Co^®Jim At -data
mq br°
n,io, Mur PI^r
I Module Diagram I
Yun4rmm'xh)
I I-V Curves I
P
11
s
�.tl0alw)fY
r,OertmA� 4
arrw%w
(4M'Etler
f!YlKida
raaaawac
1+e•h
mp ler
T
i%al
aaao int
Pi
9P'%9n
g C 'rI W139'I
tq
trLngan%•x2A1NOEf
R
c
coon
1tn
srcraecc
.arca xan -o
I Installation Safety Guide I
Only qualified personnel should install or perform maintenance.
Be aware of dangerous high DC voltage.
Do not damage or scratch the rear surface of the module,
Do not handle or install modules when they are wet.
+r,n IA7
ad Miss-4roae,r
ppwaP[arwp.PY
gnprA lep.aK
M•eehlrwq.NK
^ -�ea1p CAMq.NK
anwµl wwrM
_.1aa ssae
Ca M•-aK
46'C t 2
-40 85 C
DC 1,000 V (IEC)
DC 600 V (UL)
15 A
cr- or,
Roject Number:
Dem: 03/09/12
NTS
Sane, TOm:
Module
Drawbp Number.
PV -05
Inverter Specifications
SUNNY BOY 500OUS / 6000US / 700OUS / 8000US Pi ethnical Data
• HigWv CEC eflioimcy is ds class • S"".l•clmmcs.-k-nt d +_ Ideal for residerrkal or commercial
• tw gmt d loodbreri rated Opkcool. Pplic.6-
lockable DC disconmtet sw8ch • Comiambensiv. SMA • Sunny Tovror compaibi•
• Integrated fused sones skiing comtrrunicotons and data 10 year standard warranty n ��
combin.r cdl.chon oprions • UL 1741/IEEE-1547 compliant V
SUNNY BOY 5000US/6000US/7000US / 8000US
The best in their class
Our US series inverters utilize our proven technology and are designed specifically to meet IEEE -1547 requirements.
Sunny Boy 6000US, Sunny Boy 7000US and Sunny Boy 6000US ore also compatible with the Sunny Tower. Increased
efficiency means better performance and shorter payback periods. pJl four models are held -configurable for positive
ground systems making them more versatile than ever. Throughout the world, Sunny Boy is the benchmark for PV inverter
performance and reliability.
Recomm.nd.d Morimum PV Poway fModuls STC)
DC Mauna. Vokage
Peak Power TrockkV Vokoge
OC M..imum input Current
Number of Fused Skmg Inpws
PV Start V.1toge
AC Nominal Power
AC Mo..- Oviput Power
AC M.A- Ougwt Cvrrml (0 208, 240, 277 Vl
AC Nominal Valmge Range
AC h" --y; --I / rang.
Power Factor (Nominal(
Peak Ir..W EBidency
CEC Weighed Effidency
Dimenswm. W . H . D in inches
Weight / Shipping Weight
Ambi -t Temperotur. Range
P. -* ---.p'- Wight
Topology
Goofing Conc.pt
M-wmg tocol- i -d- / oureoor (NEMA 3Rf
LCD Display
Corne+miconon RSA83/...4n
Wwrar.y'. l0 years / 15 years / 20 yaaa
Complh- IEEE -929, IEEE -1517, 11L 1741,
UL 1998, ECC Pan 15 A& 8
5pacifk06ens In nn,o,v,l mr Al
1,101 E. US in -t- drip w8h gray lids.
Efficiency Curves
SSSOOOW
SO 60DOUS
S87000US
so SODOM
6250 W
7500W
8750 W
10000 W
600 V
600V
600 V
600 V
750-ABOV
250-480V
250-480V
300-4804
21 A
25 A
30 A
30A
30",wf, dx 20A
3(1-wx), A. 20A
3(imerbr), A. 20 A
3ffineneri, Ax 20A
(DC disconnect)
IDC dbcamaA
(DCd7scomwc1)
(DC discomectl
300V
300V
300 V
365 V
5000 W
6000 W
7000 W
8000 W
5000 W
6000 W
7000 W
6000W
24 A, 21 A, 18A
29 A. 25 A, 22 A
34A, 29 A. 25 A
N/A, 32 A, 29 A
183-229 V0208Y
183-229 V0208V
483-229VO208V
N/A 0208V
211 - 264 V 0 24O V
211 - 264 V 0 2AO V
211. 264 V 0 240 V
211 _ 264 Y 0 240 V
2"-305V277V241-305
V277V
244-305VO 277Y
24-305VO277V
60H./59.3 - 60.5 Hs
60 Hz / 59.3 - 60.5 Hz
60 H. / 593 - 60.5 Ha
60 H. / 59.3 - 60.5 Ha
099
0.99
099
099
96.8%
970%
971'1
96.5%
95.5%6208V
95.5%0208V
95.5%02084
N/A 0200V
95.5%0?AD V
95-5%02AOY
96.0%0240V
96.0%0240V
95.5%0277V
96.0%0277V
96.0%4277V
96.0%0277V
18.4 x24.1.9.5
18.4 x24.1 x9.5
18.4 .24.1x9.5
ICA .24.1 .9.5.
141 lbs/ IAS lb,
14116,,/14B W.
14116,,/ 14816.
14887,,/ 1521sn
-13 to 113'F
-13ta113'F
-137E+113'F
-13 to 113-F
0.1 W
0.1 W
0.1 W
0.1 W
Lowfregencytransformer,
Lawheq... cykmrdormer,
low frequency nandornrer,
low Freguenry Imnsfarmer,
In* tlnawow
rruo 34no wo
kw ilnowave
Iruo sinowoso
OptiCoopv,
OpticoolTM,
Optic -11-!
Optic -11.
forced actio. -.69
forced act - -.line
forced alive cooling
for -d acl- coolmg
./.
0/0
0/6
0/6
•
•
•
•
•
•
•
. Inclvdod
O Opticnal
Tel. +1 916 625 0870
Toll Free +1 888 4 SMA USA
www.SMA-America.com
SMA America, LLC
W
Z �kn
ASN
f�W�V
tr
zNa
OM
aW
V
I�
Eli*
W � V
WHO
4 �
Dr by Frank Alonso
aw x te:
Pralsa Nu~
oae: 03/09/12
S .N: NTS
sne.7 nue:
Inverter
D..., Num.•r'
PV -06
,,,e
x•a sma
P- NA swro eon ran
Tel. +1 916 625 0870
Toll Free +1 888 4 SMA USA
www.SMA-America.com
SMA America, LLC
W
Z �kn
ASN
f�W�V
tr
zNa
OM
aW
V
I�
Eli*
W � V
WHO
4 �
Dr by Frank Alonso
aw x te:
Pralsa Nu~
oae: 03/09/12
S .N: NTS
sne.7 nue:
Inverter
D..., Num.•r'
PV -06
Villanueva Residence . La Ouinta • 80325 Via Pessam
Inverter String Sizing Configuration
Evaluation of design
Vintage Electric
48587 Marin Ct. Project name: Villanueva Residence
Project number:
Indio, CA 92201
Project file:
Tel.: (760) 834-2204 Part project 1
Location: United States of America / La Quinta
Ambient temperature:
Record Low Temperature: 13.00 *r
Average High Temperature: 107.00 IF
Record High Temperature: 123.40 IF
Fax:
E -Mail: james@vintageelectric.us 1 x SS BOODUS — 240VAC
Intemet: www.vintageelectric.us
PV peak power: 10.42 kWp
Total number of PV modules: 42
Project name: Villanueva Residence Location: United States of America / La Number of Inverters: 1
Project number. Max. DC power: 8.60 kW
Projekt file: Grid voltage: 1240 V Max. AC power: 7.68 kW
Grid voltage: 240 V
6"6a"_ Nominal power ratio: 83% Q
SB 8000US - 240VAC
42 x Hyundai HiS-S248MG (US) (PV -array 1)
Azimuth angle: 01, Inclination: 01, Mounting type: Roof, PV peak power: 10.42 kWp
111 x SB 8000US - 240VAC
Total number of PV modules:
42
Energy usability factor: 99.6%
PV peak power:
10.42 kWp
Performance ratio (approx.)'! 83.2 %
Number of Inverters:
1
Spec. energy yield (approx.)*: 1432 kWh/kWp
Nominal AC power:
7.68 kW
Line losses (in % of PV energy): ---
AC active power:
7.68 kW
Unbalanced load: 7.68 kVA
Active power, ratio:
73.7%
Self -consumption: ---
Annual energy yield (approx.)*:
14912.60 kWh
Seff-consumption quota: ---
Max. PV voltage:
589 V
Signature
*Important: The yield values displayed are estimates. They are determined
mathematically. SMA solar Technology AG accepts no responsibility for the real
yield value which can deviate from the yield values displayed dere. Reasons
for deviations are various outside conditions, such as soling of the PV Modules or
fluctuations to the efficiency of the PV modules.
O
Max. DC current:
Input A: PV -array 1
42 x Hyundai HiS-5248MG (US), Azimuth angle: 01, Inclination: 01, Mounting type: Roof
PV/Inverter compatible
Input A:
Number of strings:
3
PV modules per string:
14
Peak power (input):
10.42 kWp
Typical PV voltage:
352 V
0
Min. PV voltage:
325 V
0
Min. DC voltage (Grid voltage 240 V):
300 V
Max. PV voltage:
589 V
0
Max. DC voltage (PV):
600 V
Max. current of PV array:
24.6 A
O
Max. DC current:
30.0 A
PV/Inverter compatible
i�
�
U
N
Draw^ w
Frank Alonso
cn� ey:
P,oixt N...,:
D..
03/09/12
s^,m
NTS
s1e T 1
Inverter
Config
Dewing Number'.
PV -07