Loading...
04-4979 (SFD)TA* hf 4 44" � r� Y BUILDING & SAFETY DEPARTMENT - `P.`0. B�OX'1304„ (760).777-7012 �T8-49-5yC-A LLE°j MPICo z FAX (760) 777-7011 LA Q�UtNT,a, CIA T��IFORNIA 92253 INSPECTION_.-R•EQUES-TS(760) 777-7153. ate, I I BUILDING PERMIT Application Number (04-00004979? Date 8/06/04 Property Address 8 -0300 -VIA PESSARO APN: 772-550-003- - - Application description .. DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . LOW DENSITY RESIDENTIAL Application valuation . . . . 412748 Owner Contractor BEN NANCE ------------------------- NANCE ENTERPRISES,INC., BEN P 0 BOX 2589 P.O.-BOX 2589 LA QUINTA CA 92253 PALM DESERT CA 92261 (760) 345=2030 WCC: STATE FUND WC: 0460013266 06/01/05 CSLB: 814971 11/30/04 CCC: B r ------- Structure Information 4653 SQ. FT. SFD ----- Construction Type . . . . . TYPE V- NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . . . :NON -AO FLOOD ZONE Other struct info. . . . CODE EDITION 2001 CBC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 982.00 PATI.O SQ FTG 1428.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 4653.00 ---------------------------------------------=------------------------------ Permit . . . . . . BUILDING PERMIT Additional desc'. Permit Fee 1735.00 Plan Check Fee 1127.75 Issue Date . . . . Valuation . . . . 412748 Qty Unit Charge Per Extension BASE FEE 639.50 313.00 3.5000 THOU BLDG 100,001-.500;000 1095.50 ------------------------------------------------------------ Permit . . . . . ELEC-NEW RESIDENTIAL ---------------- Additional desc Permit Fee 212.50 Plan Check Fee 53.13 Issue Date . . . . Valuation . . . . 0 Qty • Unit Charge Per Extension P.O. BOX 1504• :���/; , w VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA92253INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Of ^ -f - q 7 9 I Date: Applicant: G 0 I r t211c OJT Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's"Address: r'L'ic: No.: --67;z: tsUILUING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my Lic: is in WIforce and effect. L / License Class 1 (►> 6� C C. License No. -S/ 7 7 Dat - O I/ coon OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): (--) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale.' If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is — issued. My workers' compensation insurance carrier and policy number are: arri Cer rr s7ev-/-ft. )S- -- -0 I Policy. Number A) O !�L o D4 7 Z G L _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. -L -O -iant l WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date/2-1J - C `'' S gnature (Applicant or Page 2 Application Number 04-0000.4.979 Date 8/06/04 Qty. Unit Charge PerExtension, BASE FEE; 15.00 4653.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 162.86 982.00 0200 ELEC.GARAGE OR NON-RESIDENTIAL 19.64 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 - Permit . . GRADING PERMIT-* .Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 Permit . . . . MECHANICAL Additional desc'_. Permit Fee 157.00 Plan Check Fee 39.25 Issue Date . . Valuation .0 Qty Unit -'Charge Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE -<=100K 45.00 5.00 '9.0000 EA' MECH B/C <=3HP/100K BTU 45.00 .7.00 6.5000'EA MECH .VENT FAN - 45.50 1.00 6.5000 EA MECH EXHAUST,HOOD 6.50 Permit . .. . PLUMBING Additional desc Permit Fee 215.2.5 Plan Check Fee 53.81 Issue Date Valuation . . . . 0 Qty Unit Charge Per, Extension BASE FEE 15.00 21.00 6.0000 EA PLB FIXTURE 126.00 5.00 6.00.00 EA PLB ROOF DRAIN 30.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00' 3.0000 EA PLB WATER INST/ALT/REP 3.00,`'` 1.00 9.0000 EA, PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500' EA' PLB GAS PIPE >=5 9.75 1.00 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments 4653 SQ. FT. SFD ,. THIUS PERMIT DOES NOT Page 3 Application Number 04-00004979 Date 8/06/04 ---------------------------------------------------------------------------- Special Notes and Comments INCLUDE POOL & SPA, BLOCK WALLS OR DRIVEWAY APPROACH*. Other Fees ART.IN PUBLIC PLACES -RES 531.87 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 112.78 DIF FIRE.PROTECTION-RES 97.00 GRADING.PLAN CHECK FEE .,00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC. -RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 41.27 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due Permit Fee Total .2334.75_ ..00 .00 2334.75 Plan Check Total 1273:94 250.00 :00 1023.94 Other Fee Total 3090.92 .00 .00 3090.92 Grand Total 6699.61 250.00 .00 6449.61 r P.O. BOX 1504 BuildingJ90 � t pV 78-495 CALLE TAMPICO Address V 11 LA QUINTA, CALIFORNIA 92253 APPLICATION ONLY Owr)g� ,� tt OCC. GRP. v I BUILDING: TYPE CONST y-� A.P. Number—7 Z � D —� �t G� Legal Description UT r Project Description Mailing Address City City Zip Tel. Contractor i Address 0 Bo City C M o& Zip s i 4. - Tel 6 L6 Sq. Ft. s`� No. No. Dw. Size J Stories Units State Lic. & Classif. 2 City Lic. # Arch., Engr., , i ^, C� Designer � W New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address �r Tel. �i `� r��X60 7Tl% . > Its ��- ZrZ21.IState G26 (� r _ LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway En . Infrastructurill I Intl TOTAL REMARKS ZONE: BY:_ Minimum Setback Distances: FINAL DATE Issued by: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line INSPECTOR Date Permit I Validated by: Validation: 0 Z4 12, YELLOW = APPLICANT PINK =FIN NCE x T CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES RANCHO MIRAGE d Date 12/6O/04 La Quinta,.CA 9225.3 INDIAN WELLS No. 26680B(760) 771-8515 JPALM oT L QUINTA, INDIO .y7ti� a Owner Ben Nance APN # 772-550-003 Address Jurisdiction La Quinta City Zip " ` Permit Tract # .: �.. Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot .# No. Street S.F. Unit 1 80300 Via Pessaro 4653 Unit 6 Unit 2 , Unit 7 Unit 3Unit 8` Unit 4 ';;, Unit 9 - Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq:" w in the amount of $2.24X 4,653 S.F. or $10,422.72 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage• in this proposed project may now be issued. Fees Paid By CC/Pacific Western Bank - Ben Nance 'Check No. 243034 Name on the check - Telephone 333-6666 Funding Residential By Dr. Doris Wilson -� Superintendent Fee collected /exem ed by Sh on Mc ilvrey Payment Recd $10,422.72 over/Under .Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant :Copy - Applicant/Receipt Copy - Accounting- ICE ; .O IA 002/003 OQ' - CITY OF LA QUINTA BUILDING & SAFETY DEPARTMENT Of 771'-7012 i INSPECTION REQUEST LINE 777-7153 Owner k� f .0. Dxy--- Contr4otorNANCE EXTYMPMES INC. Permit Nwmt1 ' OL� " �iq �.S POST`O�V JOB I ' PICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES.;' JOB ADDRESS 89 -306 -VIA PESSARO 4653 SQ., FT. SFD THIS PERMIT DOS$ NibT. INCLUDE POOL & SPA, BLOCK WALL'S OR DRWKWAY APPROACH. TYPE OF INSPECTION DATE isimp, TEMPORARY POWER SETBACKS U/G ELECTRICAL/ GROUNDING{ - FOOTINGS / STEEL CONCRETE SLAB DO NOT POUR CONCRETE UNTIL ABOVE SIGNED ROOF NAIL/ PRE -ROOF 41 —1 OKAY TO WRAP FRAMING COMBINATION ROUGH ELECTRIC ROUGH PLUMBING ,•' ROUGH MECHANICAL INSULATION - c COVER NO WORK UNTIL ABOVE SIGNED INTERIOR GYP, BD. DRYWALL -- EXTERIOR LATH - - 5 GAS TEST ,�'> ,2; ? - ' SEPTIC ABANDONMENT SEWER CONNECTION .. .. •j = SEPTIC/ GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS LUX U/G ELECTRICAL P_ RE -PLASTER (ALARMS/ BARRIERS) FINAL INSPECTIONS TEMP. USE OF PERMANENT POWER -06 -O ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL/ JOB COMPLETED ABOVE APPRJI7 O DO NOT INCLUDE RIGHT TO " TURN ON LIT FLITIES OR OCCUPY BUILDING .. � V.._ J � } .tf� r .. ,,,y �. ` ,) J;'� .'' R1 •, /4 - .. n ,.. rte- it / :+ ^� . - ert�fica a of O.ccu an. 10 j XDWORAhv a • ] G OF. � a ; Buildin AS afet + ,o artmen# f _ 1 This Certificate .is issued pursuant -to the r'equirements'of,Secdo 109�of fhejCalifornia-'Building Code certifyingthat at ; the Y une of 'issuance; this,�sfructuce," wash in compliance r with ;= . ,the provisions ,of the -Building Coale and -the'various ordinances of *the, -. .City regulating building -,� -., �- ..,.'; 5 r -cons tr`uction.and/or_use f y 4 "BUILDING ADDRESS 80-300`�VIA PESSARO..` � Use�classification: S.F.D. Building Permit No.: 4=4979 s ,_ Group R-3,-%;, Type Construction: `J> '`.' .Occupancy w of •V -N :f ; - LandrUse Zone R=L' 07 j Owner of Building: BEN'NANCE - - Address: B.O. BOX 2589= City,: ST; ZIP: LA QUINTA CA 92253 - TG By SHOWALTER` �.•�t„L ;." `, ;~Date: M/15/06 . - h Building -Official : POST. INA CONSPICUOUS PLACE , TIT,LE.24 REPORT "~ Title 24 Report for6,'�d� ®� e The Ben Nance Residence�\�/ "�10 S /1 Lot #189 Via Chante @ "The Hidea�y`" ybs�Q/J6'O fib° La Quinta, CA 92253 42 Project Designer: Andrzej W. Weber A.I.A. 74-133 EI Paseo, Suite A 'Palm Desert, CA 92260 4 (760) 340-3002 Report Prepared By: CJ Mcfadderi BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211— (760) (760) 346-0855 Job Number: Date: 7/29/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is •� authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. - -Uw Number.. -3665 V�i�Qb 6tIC� Zeal rite 'Certificate of Compliance: Residential (Part 1 of 2) CF -1 R The Ben Nance Residence Fenestration 7/29/2004 • Project Title Date Lot #189 Via Chante @ "The Hideaway" La Quinta Assembly_ Project Address Type Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan check/ Date Documentation Author Telephone Wood Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION W-2 Wall (W.21.2x6.16) Wood. Total Conditioned Floor Area: 4,653 ft2 Average Ceiling Height: 11.4 ft Total Conditioned Slab Area: 4,653 ft2 0.756 Building Type: Slab On Grade n/a (check one or more) Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door X❑ Single Family Detached ❑ Addition Exterior Door ❑ Single Family Attached ❑ Existing Building ❑ ❑ Multi -Family ❑ Existing Plus Addition Rear Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 ScreenX❑ Number of Stories: 1 ❑ Raised Floor E BUILDING SHELL INSULATION Orientation Area Fenestration Exterior Const. Component Frame Assembly_ Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 `Exterior Roof W-1 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall W-2 Wall (W.21.2x6.16) Wood. 0.057 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door Wood 0.387 Exterior Door FFNFSTROTInN Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (North) 54.0 0.35 0.33 Bug Screen X❑ ❑ ❑x❑ Left (North) 96.0 0.35 0.27 Bug Screen ❑ X❑ ❑ Q Left (North) 50.3 0.40 0.38 Bug Screen ❑ X❑ ❑X❑ Rear (East) 35.0 0.40 0.38 Bug ScreenX❑ ❑ ❑ X❑ Right (South) 8.0 0.35 0.33 Bug Screen ❑ X❑ ❑ x❑ Right (South) 40.0 0.35 0.27 Bug Screen ❑ x❑ ❑X❑ Right (South) 46.3 0.40 0.38. Bug Screen ❑ X❑ ❑ x❑ Front (West) 54.0 0.35 0.33 Bug Screen X❑ ❑ ❑ X❑ Front' (West) 60.3 . 0.40 0.38 Bug Screen ❑ x❑ ❑X❑ Rear (East) 126.0 0.55 ' 0.52 Bug Screen x❑ ❑ El X❑ Rear (East) 43.6 0.40 0.38 Bug Screen ❑ X❑ ❑X❑ Front (West) 126.0 0.55 0.52 Bug Screen ❑ x❑ ❑ X❑ Run Initiation Time: 07129/0410:42:10 Run Code: 1091122930 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:3 of 42 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Ben Nance Residence Fenestration 7/29/2004 •The Project Title Date Lot #189 Via Chante "The Hideaway" La Quinta SHGC Project Address Yes/ No Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/Date Documentation Author Telephone 0.80 Computer Performance 15 Field Check 1 Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION (Northeast) 38.0 Total Conditioned Floor Area: 4,653 ft2 Average Ceiling Height: 11.4 ft Total Conditioned Slab Area: 4,653 ft2 [1 Building Type: Rear (East) (check one or more) 0.35 0.33 X❑ Single Family Detached 0 Addition C3 ❑ Single Family Attached ❑ Existing Building (Southeast) ❑ Multi -Family ❑ Existing Plus Addition 0.38 Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 (South) Number of Stories: 1 - ❑ Raised Floor C BUILDING SHELL INSULATION Const. Component Frame Assembly _ Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shad ing, Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes/ No Yes / No Skylight 7.0 0.80 0.43 None ❑ [i ❑ x❑ Left (Northeast) 38.0 0.35 0.33 Bug Screen ❑ [1 ❑X❑ Rear (East) 20.0 0.35 0.33 Bug Screen ❑ C3 ❑ x❑ Rear (Southeast) 12.0 0.40 0.38 Bug Screen x❑ ❑ ❑ x❑ Right (South) 60.0 0.40 0.38 Bug Screen x❑ ❑ ❑ x❑ Right (Southwest) 48.0 0.35 0.27 Bug ScreenX❑ ❑ ❑ Q Front (West) 48.0 0.35 0.27 - Bug Screen x❑ ❑ ❑ x❑ Left (Northeast) 43.3 0.40 0.38 Bug Screen ❑ K ❑ x❑ Rear (East) 48.0 0.35 6.27 Bug Screen x❑ ❑ ❑ x❑ Left (Northeast) 48.0 0.35 0.27. Bug Screen ❑ x❑ ❑ x❑ Right (South) 72.0 0.35 0.27 Bug Screen x❑ ❑ ❑x❑ El El El Run Initiation Time: 07129/04 10:42:10 Run Code: 1091122930 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:4 of 42 lu E • • 'Certificate of Compliance: Residential (Part 2 of 2) CF -1 R The Ben Nance Residence 7/29/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments (ventral Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 (Master Suite) Central Furnare 80% AFUE Ducts in Attir. 42 Setback HVA Great Room) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 (Kitch/Nook/Dinning) Central Furnnre 80% AFUE Ducts in Attic 4.2 Setback HVAC -4 (Bedroom #2) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -5 (Bedroom #3 & 4) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Sethack HVnr_1 (Master Shite) Split Air Conditioner 14 0 SFFR Ducts in Attic 42 Sethack HVAC -2 (rraat Rnnm) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC-. (Kitch/Nook/Dinning) Split Air Conditioner 14.0 SEER Ducts in Attic - 4.2 Setback HVAC -4 (Bedroom #2) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -5 (Bedroom #3 & 4) WATER HEATING SYSTEMS 1 1 1 Rated Tank Energy Fact. External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O.Smith FSG -100 Large Gas Recirc/Time+Temp 1 78 000 100 0.82 0.0000 0-0 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Andrzej W. Weber A.I.A. Address: 74-133 EI Paseo, Suite A Palm Desert, CA 92260 Telephone: 760 340-3002 Lic. #: I1 2 �o a . (sign Ore) (date) Enfor gement Agency Name: Title/Firm: Address: Telephone: Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 tia (signature) (date) (signature/stamp) (date) Run Initiation Time: 07/29/04 10.42.10 Run Code* 1091122930 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:5 of 42 Certificate of Compliance: Residential (Addendum) CF -1 R Title 7/29/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field • The HVAC System "HVAC -1 (Master Suite)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 122 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 122 sqft Exposed Slab Floor, 3.50" thick at HVAC -1 HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1019 sqft Covered Slab Floor, 3.50" thick at HVAC -1 The HVAC System "HVAC -2 (Great Room)' must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 823 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 823 sqft Exposed Slab Floor, 3.50" thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 92 sqft Covered Slab Floor, 3.50" thick at HVAC -2 The HVAC System "HVAC -3 (Kitch/Nook/Dinning)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Area;. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1196 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1196 sqft Exposed Slab Floor, 3.50" thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 142 sqft Covered Slab Floor, 3.50" thick at HVAC -3 The HVAC System "HVAC -4 (Bedroom #2)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC -1 (Master Suite)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 (Great Room)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3 (Kitch/Nook/Dinning)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rate must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -4 (Bedroom #2)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -5 (Bedroom #3 & 4)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: Page:6 of 42 1 Certificate of Compliance: Residential (Addendum) CF-1 R The Ben Nance Residence 7/29/2004 roject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local PnfA.PPmPnt nnPnry r1PrPrminPc the adeauacv of the iustification. and may refect a building or desiqn that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 42 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 42 sqft Exposed Slab Floor, 3.50" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 382 sqft Covered Slab Floor, 3:50" thick at HVAC -4 The HVAC System "HVAC -5 (Bedroom #3 & 4)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Area;. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Tile in Mortar Interior Mass,0.75" thick at HVAC -5 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Exposed Slab Floor, 3.50" thick at HVAC -5 HIGH MASS Desiqn(see C -2R) - Verify Thermal Mass: 751 sqft Covered Slab Floor, 3.50" thick at HVAC -5 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:7 of 42 A7/"1n/AA An.A-1.4A 0— I—A-- 4no4,I77C EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:7 of 42 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into . the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X I150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. ❑' § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X not apply to exterior mass walls). ❑'§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ❑X § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. . 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e):. Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. El§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. El§ 150(i): Setback thermostat on all applicable heating and/or cooling systems. FX§1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:8 of 42 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into • the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: 'Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) a1150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, ort-11-118113. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam _ insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. - - i b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. o§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Cj§118 (f): Cool Roof material meet specified criteria. Lighting Measures - ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. FV §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement 4 allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 3665 Job Number. Page:9 of 42 Computer Method Summary (Part 1 of 3) C -2R The_B-ec>_N.aace-Beside.nce 7/29/2004 Project Title • L.ot- #18-9_Vja_Chaate-@ The H .away"La-Qu.inta Date Project Address Building Permit # _BREE7 AI SOlVD1TLONIN-G (760) 346-0855 Plan Check/Date Documentation Author Telephone Computer-Ple-rformance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.05 4.35 -0.29 Space Cooling 37.05 33.67 3.38 Domestic Hot Water 6.12 3.93 2.20 Totals 47.23 41.94 5.29 Percent better than Standard: 11.2% BUILDING COMPLIES Total Conditioned Floor Area: 4,653 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 25.4% Number of Dwelling Units: 1.00 Total Conditioned Volume: 53,146 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 4,653 ft 2 BUILDING ZONE INFORMATION Zone Name Floor Area Volume JiVAC_1 (M.asier_Suite) .IiVAC2(Gre. t Roomi -H- -3 (-3 (Butch/Nook/DinoiIIg) HVAC -4 (Bedroom #2) OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Ro.O.f— 1 141 ---D-0.2,8- 345 —0 _Wall 345 0 057 _0 90 Wall_ 109 0 057 _90_ go Wall 54 0.057 90_ _9-0 Wall— 713. 0"057 180 _ 90 Wall— 158 0 057 270 90 Root— 915 02$ X45 0 V\(all 113 0.057 90 90 Wall_ 113 0 057 270 90 Roof— 1,331 0.028 345 0_ Wall_ 152 0,057 0-90_ WaIL_ ---JAB 0.057 45 90 Wall— 43 0 057 _ go 90 Wall— 5o 0.057 90 _90 Wall— 6$ 0.9.52 g.0_ Wall_ 208 0_055 _18.0 go Wall_ 68 —0-057 225_ —00 Wall_ 60 0.057 270 _90 Wall_ 30 0.057 315 90 .Door— 24 0.-.85 315 go RQQo.— 424 0.02$ 345 0 Wall— 85 0-057 0 go Vj(all 54 0.057 _0_ 90_ -W.;4 11 105 0.057 g0_ go Wall— 106 0.057 180 90 _wall _ 31 - 0.055 270 90 Roof— ---M5 0"028 345 0 Wall_ 75 0.057 0 90 1 141 91 5 1338 424 Solar Gains Y/N # of Units Zone Type () ?-C; _0.20 Living 0-29 Living 0.09 Sino Form 3 Reference HVAC -1 HVAr-1 HVAC -1 Thermostat Vent Type Hgt. Area SIP -Pp _2 n/a _LivJngStat nLa Living tat _�/a. S`leeoina tat _2 n/a Location / Comments EnergvPro 3.1 By EnergvSoft User Number: 3665 Job Number: Page: 10 of 42 Computer Method Summary (Part 1 of 3) C -2R Jhe_B_e.n_Nan-ce- eside.nce 7 L 2912Qn ANILProject Title Date Project Address Buildin Permit # 9 BBEE7F AIR C-ONDITIONING (760) 346-0855 Documentation Author Telephone Plan Check/Date C�m.Izuter�erform.aace 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed' Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.05 4.35 -0.29 Space Cooling 37.05 33.67 3.38 Domestic Hot Water 6.12 3.93 2.20 Totals 47.23 41.94 5.29 Percent better than Standard: 11.2% - Total Conditioned Floor Area: 4,653 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 25.4% Number of Dwelling Units: 1.00 Total Conditioned Volume: 53,146 ft' Number of Stories: 1 Total Conditioned Slab Area: 4,653 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area 1iVAC5 _(.B.e&oom #3 X 4) Al a 350 )18_ Sleeping— SleEpingStat_ —n/n • Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N/ N Form 3 Reference Location / Comments Wall 207 0.057 455 9Q _D9_0_ I_I W-1 Wall 6N212x6.16) HVAr-5 Wall 45 _0.057 45 _9A_ [I ❑ W-2 Wall (W 21 2x6 16) HVAC -5 Wall_ 30_ 0 057 90_ _90_ ® ❑ WL-2Wall (W212x6 16) HVAC -5 Wall 111 0.057 180 90 [K ❑ 2x6.16) HVAC -5 Wall 180 0.057 270 90 X ❑ W-2 Wall (W 21 M-16) HVAC -5 \Nall_ _259 0.057 315 _90 X❑ ❑❑ W-2 Wall (W212x6.16) HVAC: -5 ❑ ❑ - - - ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1:1 El Run Initiation Time: 07/2910410:42:10 Run Code: 1091122930 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 11 of 42 ` Computer Method Summary (Part 2 of 3) C -2R The Ben Nance Residence 7/29/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments A- Window_Le$ (NortW 54-0 -)..35.0_ -__c 33 0 _90 S9uth West Doois_(LoLE) HVAC, -1 2 Window Left (North) 48.0 0.350 0.27 0 90 South West Doors (Lo/E) HVAC -1 3 Window Left (North) 15.0 0.400 0.38 0 90 South West Doors (Lo/E) HVAC -1 4 Window Rear (East) 35.0 0.400 0.38 90 90 South West Doors (Lo/E) HVAC -1 5 Window Right (South) 8.0 0.350 0.33 180 90 South West Doors (Lo/E) HVAC -1 6 Window Right South 40.0 0.350 0.27 180 90 South West Doors (Lo/E) HVAC -1 7 Window Right (South) 6.0 _ 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -1 8 Window Right (South) 6.0 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -1 6 Window Right ---(South 2.3 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -1 10 Window Right (South) 6.0 0.4000 38 18_0 90 South West Doors (Lo/E) HVAC -1 11 Window Front (West) 54.0 0.350 0.33 270 90 South West Doors (Lo/E) HVAC -1 12 Window Front (West) 22.0 0.400 0.38 270 90 South West Doors (Lo/E) HVAC -1 ,0 Mid Qyy Rear (East)_ 126.0 '-O-50Q 0.52 90 90 South West Doors (Lo/E) HVAC -2 14 Window Rear (East) 12.0 0.400 0.38 90 90 South West Doors (Lo/E) HVAC -2 15 Window Rear (East) 12.0 0.400 0.38 90 90 South West Doors (Lo/E) HVAC -2 16 Window Rear (East) 2.3 0.400 0.38 90 90 South West Doors (Lo/E) HVAC -2 17 Window Front (West) 126.0 0.550 0.52 270 90 South West Doors (Lo/E) HVAC -2 18 Window Front (West) 12.0 0.400 0.38 270 90 South West Doors (Lo/E) HVAC -2 Window Front (Wes) 12.0 0.400 0.38 270 90 South West Doors (Lo/E) HVAC -2 -1 20 Window Front (West) 2.3 0.400 0.38 270 90 South West Doors (Lo/E) HVAC -2 21 dight Left (North) 7.0 0.800 0.43 345 0 Bristolite Skylite HVAC -3 .22 Window Left (North) 48.0 0.350 0.27 0 90 South West Doors (Lo/E) HVAC -3 23 Window Left (North) 18.0 0.400 0.38 0 90 South West Doors (Lo/E) HVAC -3 24 Window Left (North) 6.0 0.400 0.38 0 90 South West Doors (Lo/E) HVAC -3 25 Window Left (North) 6.0 0.400 0.38 0 90 South West Doors (Lo/E) HVAC -3 26 Window Left (Northeast) 20.0 0.350 0.33 45 90 South West Doors (Lo/E) HVAC -3 27 Window Rear (East) 20.0 0.350 0.33 90 90 South West Doors (Lo/E) HVAC -3 28 Window Rear (East) 6.0 0.400 0.38 90 90 South West Doors (Lo/E) HVAC -3 29 Window Rear (East) 6.0 0.400 0.38 90 90 South West Doors (Lo/E) HVAC -3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.0 9.0 6.0 1.0 6.0 6.0 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5.0 7.5 6.0 1.0 6.0 6.0 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 dug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 _ 6.0 9.0-- 6.0 1.0 6.0 6.0 12 Bug Screen 0.76 13 Bug Screen 0.76 9.0 14.0 10.0 0.1 10.0 10.0 14 Bug Screen 0.76 15 Bug Screen 0.76 _ 16 Bug Screen 0.76 _ 17 Bug Screen 0.76 18 Bug Screen 0.76 _ 19 Bug Screen 0.76 20 Bug Screen 0.76 _ 21 None _1 00 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 Bug Screen 0.76 _ •28 29 Bug Screen 0.76 EnergyPro 3.1 By EnemySoft User Number: 3665 Job Number. Page: 12 of 42 Computer Method Summary (Part 2 Of 3) C -2R The Ben Nance Residence 7/29/2004 ,Project Title Date - FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments _3D. Window -Re -a (Soutbaast) 19 _0AQ0 _0-3_8_ _]35_ _ 90 Snutb�8Le.st Doors (Lo/E) HVAC -3 31 Window Right (South) 6.0 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -3 32 Window Right (South) 24.0 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -3 33 Window Right (South) 12.0 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -3 34 Window Right (Southwest) 48.0 0.350 0.27 225 90 South West Doors (Lo/E) HVAC -3 35 Window Front (West) 6.0 0.400 0.38 270 90 South West Doors (Lo/E) HVAC -3 3E Window Front (West) 6.0 0.400 0.3$ 270 90 South West Doors (Lo/E) HVAC -3 37 Window Front (West) 48.0 0.350 0.27 270 90 South West Doors (Lo/E) HVAC -3 38 Window Left (North) 5.3 _0,400 0.3$ 90 South West Doors (Lo/E) HVAC -4 39 Window Left (Northeast) 8.0 0.350 0.33 45 . 90 South West Doors (Lo/E) HVAC -4 40 Window Left (Northeast) 5.3 0.400 0.38 45 90 South West Doors (Lo/E) HVAC -4 41 Window Rear (East) . 5.3 0.400 0.38 90 90 South West Doors (Lo/E) HVAC -4 A2 WiDdow Rear (Fa__ s_tl X8.0 0,350 0-27 --99_ 90 South West Doors ( o�/F) HVAC -4 _ 43 Window Right (South) 20.0 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -4 44 Window Left (Northeast) 10.0 0.400 0.38 45 90 South West Doors (Lo/E) HVAC -5 45 Window Left (Northeast) 48.0 0.350 0.27 45 90 South West Doors (Lo/E) HVAC -5 46 Window Left (Northeast) 18.0 0.400 0.38 45 90 South West Doors (Lo/E) HVAC -5 47 Window Left (Northeast) 10.0 0.400 0.38 45 90 South West Doors (Lo/E) HVAC -5 48 Window Left (Northeast) 10.0 0.350 0.33 45 90_ South West Doors (�Lo/E) HVAC -5 49 Window Right (South) 24.0 0.350 0.27 180 90 South West Doors (Lo/ )-- , - - -- HVACz5 -- 50 Window Right (South) 24.0 0.400 0.38 180 90 South West Doors (Lo/E) HVAC -5 51 Window Right (South) 48.0 0.350 0.27 180 90 South West Doors (Lo/E) HVAC -5 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 4.0 3.0 4.0 0.1 4.0 4.0 31 Bug Screen 0.76 _ 32 Bug Screen 0.76 6.0 4.0 6.0 0.1 6.0 6.0 33 Bug Screen 0.76 4.0 3.0 4.0 0.1 4.0 4.0 34 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen - 0.76 - 42 Bug Screen 0.76 8.0 6.0 9.0 0.1 9.0 9.0 43 Bug Screen 0.76 44 Bug Screen 0.76 - 45 Bug Screen 0.76 46 Bug Screen 0.76 _ 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 _ 8.0 3.0 6.0 1.0 6.0 6.0 50 Bug Screen 0.76 8.0 3.0 6.0 1.0 6.0 6.0 51 Bug Screen 0.76 8.0 6.0 6.0 1.0 6.0 6.0 EneravPro 3.1 By EneravSoft User Number: 3665 Job Number. Page: 13 of 42 1 Computer Method Summary (Part 3 of 3) C -2R 7/29/2004 uate THERMAL MASS FOR HIGH MASS DESIGN F2 Length Factor Insulation R -Val. Depth Location / Comments Sib Perimeter Area Thick. Heat .Slab-Relimeter Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar 122 0.75 24 -Oa n/a 0 HVAC -1 / Interior Mass Concrete. Heavyweight 122 3_50 28 0_98 n/a 0 HVAC -1 / Slab on Grade Concrete, Heavyweight 1,019 3.5 �2 0_98 n/a _2 HVAC -1 / Slab on Grade Tile in Mortar 823 0.75 24 0.67 n/a 0 HVAC -2 / Interior Mass Conctele_Hr,a_cyyveigh.t 823 3.50 28 098 n/a 0 HVAC -2 / Slab on Grade PERIMETER LOSSES Type F2 Length Factor Insulation R -Val. Depth Location / Comments Sib Perimeter 18 0_76 0.0 0 HVAC -1 .Slab-Relimeter 1640_76 0.0 __0 HVAC -1 Slab Perimeter 30 0.76 • 2Q 0 HVAC -2 ,Slab-etimeter 3 -0-M 0.0 0 HVAC -2 .Stab-P-erimeter 80 0.76 0.0 0 HVAC -3' HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 (Master Suite) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -2 (Great Room) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -3 (Kitch/Nook/Dinning) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -4 (Bedroom #2) *Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. • Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct. Thermostat " Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -1 (Master Suite) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -2 (Great Room) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -3 (Kitch/Nook/Dinning) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -4 (Bedroom #2) WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O.Smith FSG -100 Large Gas Recirc/Time+Temp _1_ 78,000 100 0.82 0.0000 0.0 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous. gas water heaters, list Rated Input, and Recovery Efficiency. - t 2EMARKS t Computer Method Summary (Part 3 of 3) C -2R ien Title Residence THERMAL MASS FOR HIGH MASS DESIGN F2 Area Thick. Heat Type (sf) (in.) Cap. Concrete. Heavyweight _92 -3-5D 98. Tile in Mortar 1.196 0_75 24 Concrete, Heavyweight 1,196 3.50 ---Z@ Concrete. Heavyweight 142 3_50 28 file inAx ar 42 0.75 24 PERIMETER LOSSES 7/29/2004 Date Inside ' Location Cond. Form 3 Reference R -Val. Comments _0.9$. n/a _2 HVAC=2LSlab_on Grade 0_67 n/a 0 HVAC -3 / Interior Mass 0.98 n/a 0 HVAC -3 / Slab on Grade 0.98 n/a 2 HVAC -3 / Slab on Grade 0_67 n/a 0 HVAC -4 / Interior Mass HVAC SYSTEMS Heating Equipment F2 Insulation Type Length Factor R -Val. Depth Location / Comments _Slab Perimeter 9 0.76' 0.0 0 HVAC -3 -SI.ab-Eerlmeter _ 7 S026 —U _Q HVAC -4 Slab Perimeter 60 0_76 0.0 0 HVAC -4 .SlabJ'_e[imeter 1 -0-76 --U 0 HVAC -5 -Slab Perimeter 99 0.76 0 0 0 HVAC -5 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic _4 2 _ Setback HVVAQ-5 (Bedroom #3 & 4) 10-lydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct — .Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Air Conditioner 14.O SEER Ducts in Attic 4.2 Setback HVAC -5 (Bedroom #3 & 4) -$plit WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Part 3 of 3) C -2R 7/29/2004 Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Cooling Equipment Minimum Duct Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. Heavyweight— 42 3.5Q _28_ x..98. nLa 0. ±iVAC--4LS1ab on G ade Concrete. Heavyweight 382 3_50 28 0_98 n/a 2 HVAC -4 / Slab on Grade Tile in ortar 84 0.75 4 0.67 n/a 0 HVAC -5 / Interior Mass Concrete, Heavyweight 84 3_50 28 0_98 n/a 0 HVAC -5 / Slab on Grade Coac[ele—Heav". eight 751 3.50 _28 498 n/a _2 HVAC -5 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments -------. ----- -- -- - *Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl ' Tank Energy Facts Tank Insul. Water Heater Water Heater Distribution y# in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. . Computer Method Summary (Addendum) C -2R Title 7/29/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design thatotherwise-complies based on the adequacy of the special justification and documentation submitted. I Plan Field L The HVAC System "HVAC -1 (Master Suite)' must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 122 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 122 sqft Exposed Slab Floor, 3.50" thick at HVAC -1 HIGH MASS Design(see C-213) -Verify Thermal Mass: 1019 sqft Covered Slab Floor, 3.50" thick at HVAC -1 The HVAC System "HVAC -2 (Great Room)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 823 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 823 sqft Exposed Slab Floor, 3.50" thick at HVAC -2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 92 sqft Covered Slab Floor, 3.50" thick at HVAC -2 The HVAC System "HVAC -3 (Kitch/Nook/Dinning)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Area;. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1196 sqft Tile in Mortar Interior Mass, 0.75' thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1196 sqft Exposed Slab Floor, 3.50" thick at HVAC -3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 142 sqft Covered Slab Floor, 3.50" thick at HVAC -3 The HVAC System "HVAC -4 (Bedroom #2)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS peovider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan IField The HVAC System "HVAC -1 (Master Suite)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge.and Airflow. .... _ .. __.. _. _..__._....... .. The HVAC System "HVAC -2 (Great Room)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3 (Kitch/Nook/Dinning)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rate must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -4 (Bedroom #2)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -5 (Bedroom #3 & 4)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EneravPro 3.1 By EnemvSoft User Number: 3665 Job Number: Page: 17 of 42 1 Computer Method Summary (Addendum) C-2R The Ben Nance Residence 7/29/2004 roject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local anfnrramant nnanr_v riPtermines the adanuar_v of the iustification. and may reiect a buildina or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 42 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 42 sqft Exposed Slab Floor, 3.50" thick at HVAC -4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 382 sqft Covered Slab Floor, 3.50" thick at HVAC -4 The HVAC System "HVAC -5 (Bedroom #3 & 4)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Tile in Mortar Interior Mass, 0.75" thick at HVAC -5 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 84 sqft Exposed Slab Floor, 3.50" thick at HVAC -5 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 751 sqft Covered Slab Floor, 3.50" thick at HVAC -5 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field Run Initiation Time: 07/29/04 10:42:10 Run Code: 1091122930 EnergyPro 3.1 By EnergySoft User Number: 3665 - Job Number: Page: 18 of 42 1PROPOSED CONSTRUCTION ASSEMBLY PROJECT NAME The Ben Nance Residence COMPONEN ENV -3 DATE 7/29/2004 PONENTS OUTSIDE SURFACE AIR FILM El D. El ASSEMBLY NAME ASSEMBLY W-1 Wall W.21.2x6.16 Floor 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 TYPE (check one) X Wall Gypsum or Plaster Board 6 0.562 7 1.06 Ceiling / Roof 0.31 9 0.37 W INSIDE SURFACE AIR FILM 0.6801 0.680 23.11 7.56 FRAMING MATERIAL z FRAMING % 15 % Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) PONENTS THICK- NESS (in.) 0.875 0.010 0.375 5.500 0.625 SUBTOTA R -VALUE OUTSIDE SURFACE AIR FILM El D. El 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.562 7 1.06 8 0.31 9 0.37 0.98 INSIDE SURFACE AIR FILM THICK- NESS (in.) 0.875 0.010 0.375 5.500 0.625 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.5621 0.562 0.02 1.06 0.29 0.31 2.63 0.37 0.98 '2.60 0.6801 0.680 23.11 7.56 -HEAT CAPACITY (Optional) include the effects of the framing members. WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) + [ 0.1323 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 '2.60 0.26 0.68 14.8 TOTAL HC 3.7 Rc R "NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 X 1 0.85 ] + [ 0.1323 X L 0.15 ] = 0.057 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 19 of 42 1PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME The Ben Nance Residence DATE 7/29/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM - 1 2' Gypsum or Plaster Board Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.562 5 0.37 6 ASSEMBLY NAME W-2 Wall W.21.24.16 0.68 8 ASSEMBLY U -VALUE 9 ASSEMBLY Floor 0.6801 0.680 22.98 TYPE (check one) Wall W LL Ceiling Ceiling I Roof 0 FRAMING MATERIAL Wow p Z FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) THICK- NESS (in.) 0.625 5.500 0.625 R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM - 1 2' Gypsum or Plaster Board Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.562 5 0.37 6 2.60 7 0.68 8 ASSEMBLY U -VALUE 9 INSIDE SURFACE AIR FILM THICK- NESS (in.) 0.625 5.500 0.625 R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.562 0.562 21.000 5.445 0.562 0.562 0.37 0.98 2.60 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE 0.6801 0.680 22.98 7.42 Rc Rf 0��u *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0435 X 0.85 2.60 0.26 0.68 2.63 0.37 0.98 2.60 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE 7 8 TOTAL HC 2 3 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0435 X 0.85 + 0.1348 1 X L 0.15 11= 0.057 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 20 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Ben Nance Residence 7/29/2004 �YSTEM NAME FLOOR AREA HVAC -1 Master Suite 1 141 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 89,400 Total Output (Btuh) 89,400 Output (Btuh/sqft) 78.4 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 51.3 Total Output (sgft/Ton) 234.1 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.75 Airflow (cfm/Ton) 410.3 Outside Air (%) 4.3 OutsLde Air (cfm/sqft) 0.07 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 1,218 24,780 3,133 556 23,048 24.0 OF 67.5 OF 0 108.9 OF = 1,239 1,152 0 0 86 3,282 1,952 86 4,200 86 cfm 0 .. _ ..._... _ 0 1,239. 1,152 30,540 1 5,085 HS26-060/G40UH60C-110 (5) 46,463 5,309 Peak 24.0 OF 67.5 OF 108.9 OF 108.9 OF = Supply Air Ducts Total Adjusted System Output 46,463 5,309 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm . 29 553 89,400 89,400 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 67.5 OF 108.9 OF 108.9 OF = Supply Air Ducts O Outside Air 86 cfm 108.4 OF Heating Coil Supply Fan 2000 cfm ROOMS 70.0 OF 69.5 OF Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 OF 80.1 / 65.4 OF 58.6 / 57.2 OF 58.6 / 57.2 OF Supply Air Ducts 0' Outside Air _ 86 cfm Cooling Coil SuppFan OF 59.1 / 57.4 ° 2000 cfm ROOMS 48.2% R.H. °F 78.0/64.5 OF 78.6/64.6 3.1 User Number: 3665 Return Air Ducts Job Number. 1 of 42 JHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Ben Nance Residence 7/29/2004 SYSTEM NAME FLOOR AREA HVAC -2 Great Room 915 24.0 of 67.6 of 11 ✓ . %� Outside Air 69 cfm 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 1,383 28,619 3,47 398 16,669 0 1,431 833 0 0 69 2,613 1,596 69 3,372 0 0 1,4311 833 34,0941 5,0671 21 708 HS26-048/G40UH48B-090X (4) 38,583 3,865 Total Adjusted System Output38,583 3,865 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Temperatures at Time 109.3 of Heating Coil 72,100 72,100 Jan 12 am 109.3 of Supply Air Ducts O � Supply Fan 108.8 of 1600 cfm ROOMS 70.0 of Return Air Ducts I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 114.1 / 80.3 of Outside Air 69 cfm 78.8/64.6 of 80.3 / 65.4 of 58.0 / 56.6 of V. Cooling Coil Supply Fa 1600 cfm 58.0 / 56.6 of Supply Air Ducts Fan 58.8 / 56.9 of 47.7% R.H. ROOMS 78.0 / 64.3 of k Return Air Ducts "I I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:22 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Ben Nance Residence 7/29/2004 WYSTEM NAME FLOOR AREA HVAC -3 Kitch/Nook/Dinning) 1,338 ENGINEERING CHECKS SYSTEM LOAD EATING S' 24.0 of Outside Air 100 cfm 69.5 of METRICS Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG. PEAK CFM I Sensiblel Laten I CFM I Sensible 34,1341 6,052 26 544 HS26-060/G40U H60C-1 10 (5) 45,962 6,280 89,400 Total Adjusted System Output 45,962 6,280 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am eam Temperatures at Time of Heating Peak) I 108.7 of 108.7 of Ic Heating Coil OSUPP Y it Ucts Supply Fan 108.2 OF 2000 cfm ROOMS 70.0 of i Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 of Outside —�–� 100 cfm 78.6/65.1 of 3.1 80.4 / 66.0 of M 59.1 / 57.7 of 59.1 / 57.7 of User Number: 3665 Cooling Coil : ............... Supply Air ucts Supply Fan 59.8 / 58.0 of 2000 cfm 49.6% R.H. ROOMS 78.0 ! 64.9 of E3 A,. n..-# 4 I Job Number: of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Ben Nance Residence 7/29/2004 �YSTEM NAME FLOOR AREA HVAC -4 (Bedroom #2) 424 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sgft) 84.9 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 56.6 Total Output (sgft/ron) 212.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.89 Airflow (cfm/Ton) 400.0 Outside Air (%) 4.0 Outside Air (cfm/sqft) 0.07 Note: values above given at ARI conditions :ATING S' 24.0 of >---o Outside Air 32 cfm 69.5 of 14.1 / 80.3 of Outside �'y 32 cfm 78.5/63.8 of 67.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 10,796 1,9401 HVAC E UIPMENT SELEGTION HS26-024/G40UH24A-045X (2) 19,646 1,299 36,000 Total Adjusted System Output 646 1,299 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 217M Jan 12 am tream Temperatures at Time of Heating Peak 109.4 of 109.4 of Supply Air Ducts 0 iP Heating Coil Supply Fan 108.9 of 800 cfm ROOMS 70.0 of Return Air Ducts I 79.9 / 64.6 of 11111111 . 57.2 / 55.7 of Cooling Coil Supply Fa 800 cfm 57.2 / 55.7 of =� Supply Air Ducts Fan 57.7 / 55.9 of 45.4% R.H. ROOMS 78.0 / 63.6 of I h Return Air Ducts `i EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:24 of 42 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Ben Nance Residence 7/29/2004 �YSTEM NAME FLOOR AREA HVAC -5 (Bedroom #3 & 4) 835 Outside Air (cfm/sgft) I U.Utsl L Note: values above given at ARI conditions 24.0 OF Outside 63 cfm 69.4 OF 67.0 of M Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK IICOILHTG.PEAK CFM Sensiblel Latent 11CFM1 Sensible 838 17,391 2,293 367 15,148 0 870 757 0 0 63 2,395 1,462 63 3,070 0 0 870 757 21,526T77773 755 19,734 JVAC EQUIPMENT SELECTION HS26-036/G40UH36A-70X (3) 29,031 2,852 54,100 Total Adjusted System Output 29,031 2,852 54,100 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 108:8 OF Heating Coil at Time of Supply Fan 1200 cfm 108.8 of _ ... ...-. _. —� Supply Air Ducts 108.2 OF ROOM 70.0 OF �% Return Air Ducts `S DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 °F 80.5 / 65.5 OF 58.1 / 56.7 OF 58.1 / 56.7 OF eW Supply Air Ducts Outside Air 63 ° 63 cfm F Cooling Coil Supply Fan 58.8 / 56.9 1200 cfm 47.6% R.H. ROOMS 78.7/64.5 °F 78.0/ 64.3 OF Return Air Ducts EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:25 of 42 DOOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:26 of 42 PROJECT NAME The Ben Nance Residence DATE 7/29/2004 YSTEM NAME HVAC -1 Master Suite FLOOR AREA 1,141 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLEHVAC-1 LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -1 1 1,218 24,780 3,133 1,218 24,780 3,133 556 23,048 PAGE TOTAL 1 1,218 24,780 3,133 556 23,048 TOTAL 1 1,2181 24,780 3,133 556 23,048 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:26 of 42 'ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:27 of 42 PROJECT NAME The Ben Nance Residence DATE 7/29/2004 91SYSTEM NAME HVAC -2 Great Room FLOOR AREA 915 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -2 HVAC -2 1 1,383 28,619 3,471 1,383 28,619 3,471 398 16,669 PAGE TOTAL 1,383 28,619 3,471 398 16,669 TOTAL 1 1,383 28,619 3,471 398 16,669 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:27 of 42 ' IROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:28 of 42 PROJECT NAME The Ben Nance Residence DATE 7/29/2004 YSTEM NAME HVAC -3 Kitch/Nook/Dinnin FLOOR AREA 1-338 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -3 HVAC -3 1 1,399 27,539 3,908 1,399 27,539 3,908 476 19,645 PAGE TOTAL 1,399 27,539 3,908 476 197645 TOTAL 1,399 27,539 1 3,908 476 19,645 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:28 of 42 ]ROOM LOAD SUMMARY . = EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:29 of 42 PROJECT NAME The Ben Nance Residence DATE 7/29/2004 YSTEM NAME HVAC -4 Bedroom #2 FLOOR AREA 424 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -4 HVAC -4 1 397 8,703 1,127 397 8,703 1,127 193 8,101 PAGE TOTAL 1 397 8,703 1,127 193 8,101 TOTAL 1 397 8,703 1,127 193 8,101 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:29 of 42 ROOM LOAD SUMMARY PROJECT NAME The Ben Nance Residence DATE 7/29/2004 YSTEM NAME HVAC -5 Bedroom #3 & 4 FLOOR AREA 835 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -5 HVAC -5 1 838 17,391 2,293 838 17,391 2,293 367 15,148 PAGE TOTAL 838 17,391 2,293 367 15,148 TOTAL 1 838 17,391 2,2931 367 15,148 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:30 of 42 ROOM HEATING PEAK LOADS Alh!Project Title Date Thp Ben Nance Residence 7/29/2004 Room Information Design Conditions Room Name HVAC -1 Time of Peak Jan 12 am Floor Area 1,141 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70 OF 0 Conduction ISouth West Doors (Lo/E) I Area 1,141.0 1,324.7 204.0 92.3 54.0 perimeter = 182.0 U -Value AT OF Items shown with an asterisk (f') denote conduction through an interior surface to another room. Infiltration: 1.00 x 1.080 x 1 141 x Heigh x 6] x chedule Air Sensible Area Ceiling Height ACH Fraction Page Total: 46 OT Btu/hr 1,470 3,450 3,284 1,698 142 8,281 18 326 = 4 722 *I TOTAL HOURLY HEAT LOSS FOR ROOM 23,048 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 31 of 42 I ROOM HEATING PEAK LOADS Project Title Date AlwiThe Ben Nance Residence 7/29/2004 Room Information Design Conditions Room Name HVAC -2 Time of Peak Jan 12 am Floor Area 915 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10 611 Infiltration: [ 1.00 x 1.080 x 915 x 16.00 x 0.50 / 6] x 46 = 6 059 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,669 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:32 of 42 915.0 X x x X x x x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ 1,179 225.4 0.0566 46.0 587 252.0 0.5500 46.0 6,376 52.6 0.4000 46.0 968 perimeter = 33.0 45.5 1,502 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10 611 Infiltration: [ 1.00 x 1.080 x 915 x 16.00 x 0.50 / 6] x 46 = 6 059 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,669 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:32 of 42 ROOM HEATING PEAK LOADS Project Title Date The Ben Nance Residence 7/29/2004 Room Information Design Conditions Room Name HVAC -3 Time of Peak Jan 12 am Floor Area 1,338 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70°F Conduction Area U -Value OT of Btu/hr R-38 Roof R.38.2x14.16 surface Area338 1,331.0 X X x X x X X. x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X 46.0 = = = = = = = = = = = = = = = = = = = = = = = = _ = = = = = = = = = = _ = = = 1,715 Bristolite Sk lite 7.0 0.8000 46.0 258 -aL(yy�� 777.0 0.0566 46.0 2,024 South West Doors Lo/E) 184.0 0.3500 46.0 2,962 0utb_We5LDoots (L 108.0 0.4000 46.0 1,987 W-2 Wall W.21.2x6.16 50.0 0.0572 46:0 132 Solid Wood Door 24.0 0.3872 46.0 427 Slab -On -Grade perimeter = 89.0 45.5 4,050 Items shown with an asterisk (•) denote conduction through an interior Infiltration: 1chedul001 e x Air Sensible x Fraction to another room. X Ceiling Height ACH.50 / 60] Page Total: OT 46 13 554 6 091 TOTAL HOURLY HEAT LOSS FOR ROOM 19,645 EnergyPro 3.1 ' By EnergySoft User Number: 3665 Job Number. Page:33 of 42 ROOM HEATING PEAK LOADS Project Title Date The Ben Nance Residence 17/29/2004 ` Room Information Design Conditions Room Name HVAC -4 Time of Peak Jan 12 am Floor Area 424 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 0 IW -2 Wall (W.21.2x6.16) I 424.0 x x x x x x x x x x x x x X x x x x X x X x x x x X x x X x x x x x x X X x x 0.0280 x x x x x x x x x X x x x X x x x x x x X x x x x X x X x x x x x x x x x x X 46.0 = = = = = = = = = = = 546 404.0 0.0566 46.0 1,052 36.0 0.4000 46.0 662 85.0 0.0572 46.0 224 56.0 0.3500 46.0 902 perimeter = 67.0 45.5 3,048 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 6,434J Infiltration: 1 1.001 x 1.080 x 424 x 9.50 x 0.50 160] x 46 = 1 667 chedule Ir Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 34 of 42 101 1200M HEATING PEAK LOADS Project Title JDate The Ben Nance Residence 17/29/2004 Room Information Design Conditions Room Name HVAC -5 Time of Peak Jan 12 am Floor'Area 835 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Cl OT OF Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11 693 Infiltration: [ 1.00 1 x 1.080 x 835 x 10.00 x 6] x 46 = 3456 Schedule Air Sensible Area Ceiling Height ACH OT Fraction • TOTAL HOURLY HEAT LOSS FOR ROOM 15,148 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:35 of 42 835.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x 0.0280 x x x x x x x x x x x x x x x x x x x x x x x. x x x x x x x x x x x x x x x x 589.0 0.0572 318.0. 0.0566 62.0 0.4000 130.0 0.3500 perimeter =110.0 I OT OF Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11 693 Infiltration: [ 1.00 1 x 1.080 x 835 x 10.00 x 6] x 46 = 3456 Schedule Air Sensible Area Ceiling Height ACH OT Fraction • TOTAL HOURLY HEAT LOSS FOR ROOM 15,148 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:35 of 42 ` 'RESIDENTIAL ROOM COOLING LOAD SUMMARY • l J The Ben Nance Residence 7/29/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: HVAC -1 780F 115DF 370E Conduction Area U -Value DETD' Btu/hr X North 56.0 = 1,789 X FxdGlsWdw 4 35.6 = 2,670 X (South) 37.0 = 2,642 X FxdGlsWdw 10 37.0 = 1,366 X .... --35.6--=- ( 26.6 ------ 110 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 8 578 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Horiz.Sldr 1 North FrnchDr (2) (North) FxdGlsWdw 3 (North) FxdGlsWdw 4 (East) Horiz.Sldr (5) FrnchDr 6 (South) (South)' FxdGlsWdw 7 (South) FxdGlsWdw 8 (South) FxdGlsWdw 9 (South) FxdGlsWdw 10 South ( 0.0 x1 X X X x x1 x x x + + + + + + + + + + 54.0 X x x X x x x X x 15 ) X )X x x x 0.36 = = = = = = = = = = 298 ( 0.0 1 48.0 15 0.30 216 ( 0.0x 1 15.0x 15)X 0.42 95 ( 26.6 1 8.4 73)x 0.423 428 ( 0.0 1 8.0 32) 0.367 94 ( 0.0 1 40.0 32)X 0.301 385 ( 0.0 6.0 32) 0.423 81 ( 0.0 1 6.0 32)X 0.423 81 ( 0.0 1 2.3 32)x 0.423 31 ( 0.0 1 1 6.0 32) 0.423 81 Sched. Page Total 1 791 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,141.X. 0.500 Watts/sgft x. 3.41 BtuhMlatt.- _.._ _ _.. 1,947 Occupants 1.00 x 1 141 x 250 Btuh/occ. / 200 sgft/occ. = 1,426 Receptacle 1.00x 1141x 1.500 Watts/sgft x 3.413 Btuh[Waft = 5,841 Process 1.00 x 1,141 x 0.000 Watts/sgft x 3.412 BtuhlWatt = 00 Infiltration: x� x 1,141 x x / 60] = 3.798 chedule Air Sensible Area Ceiling Height ACH T n Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,780 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 141 x 2001 Btuh/occ. / 200 sgft/occ. = 1 141 Receptacle 1.00 x 1 141 x 0.000 Watts/$gft X 3.41 BtuhlWaft = 0 Process 1.00 x 1 141 x 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: 1.00 x 4 840 x 1 14 x Heigh x 60] 0.00433 = 1 992 -Schedule Air Latent Area Ceiling Height .ACH ��W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3.133 EnergyPro 31 By EnergySoft User Number. 3665 Job Number. Page: 36 of 42 ` 'RESIDENTIAL ROOM COOLING LOAD SUMMARY The Ben Nance Residence 7/29/2004 • Project Title Date Room Name HVAC -1 Design Indoor Dry Bulb Temperature: 780E Design Outdoor Dry Bulb Temperature: 1 15oF Design Temperature Difference: 370F 9 is Conduction Area U -Value Btu/hr 1. Design Equivalent Temperature Difference (DETD) - Page -Total - - --o Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Horiz.Sldr 11 (West) ( 34.2 X 1 + 19.8 x 73 )X 0.36 = 719 6tdr,IcWdw (12) (West) ( 0.0 x 1 + 22.0 x 73 ) x 0.423 = 679 ( x + x )x = ( x + x )x = ( x + x )x = ( x + X )x = ( x + x )x = ( x + x )x = ( x + x )X ( x + x )x = Sched. Page Total 13ss Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,141 x 0.500 Watts/sqft x 3.413 Btuh/Watt = 1.947 Occupants 1.00 X 1,141 X 250 Btuh/occ. / 200 sqft/occ. = 1,426 Receptacle 1.00 x 1,14 X 1.500 Wafts/sqft X 3.413 Btuh/Watt = 5,841 Process r 1.00 x.. 1,141 x .. 0.000 Watts/sgft x 1 3.41 Btuh/Watt = o Infiltration: I 1.00 x x 1,141 x�Oo x / 60] � = a Air Sensible Area Ceiling Height ACH Frractioactio n TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24 780 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 141 x 2001 Btuh/OCC. / 200 sgft/occ. = 1 141 Receptacle 1.00 x 1 141 x 0.000 Wafts/sqft X 3.41 BtuhNVatt = o Process r 1.00 x 1 141 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = o Infiltration: I 1.00 x 4 840 x 1 14 x 10.00 X 0.50 / 60] 0.00433 = 1 992 `schedule Air Latent Area Ceiling Height ACH \W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,133 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 37 of 42 • • • 'RESIDENTIAL ROOM COOLING LOAD SUMMARY The Ben Nance Residence 7/29/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value 915. X DETD1 X 56.0 X 35.6 X 37.0 X 37.0 X X X X X HVAC -2 780F 115°F 370F Btu/hr 1,435 454 5,128 778 1. Design Equivalent Temperature Difference (DETD) Page Total 7 796 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Sld GlsDr 13 X1 x x x x x x x x x (East) + + + + + + + + + + 15.4 (East) FxdGlsWdw Abv. 15 (East) FXdGISWdw Abv. 16 (East) SldgGIsDr (17) 73) (West) FXdGISWdw Abv. 18 (West) FxdGlsWdw Abv. 19 West FxdGlsWdw Abv. 20 (West) 73) 71 ( 0.0 ( 110.6 X1 x x x x x x x x x + + + + + + + + + + 15.4 x x x X x x x X x X 73) X x X x x X )x )X 0.579 = 0.423 = 0.423 = 0.423 = 0.579. = 0.423' = 0.423; = 0.423 = = = 1,611 ( 0.0 1 12.0 73) 371 ( 0.0 1 12.0 73) 371 ( 0.0 1 2.3 73) 71 ( 0.0 1 126.0 73)x 5,324 ( 0.0 1 12.0 73)X 371 ( 0.0 1 12.0 73) 371 ( 0.0 1 2.3 73) 71 ( ( Sched. Page Total 6 560 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 915 x 0-50C Watts/sgft x 3.41 BtuhMatt = 1,561 Occupants 1.00 x 915 x 250 Btuh/OCC. / 200 sgft/occ. = 1,144 Receptacle 1.00 x 915 x 1.500 Wafts/sqft x 3.413 Btuh[Watt = 4,684 Process 1.00 x 915 x 0.000 Watts/sqft xc 3.41 BtuhlWatt = 001 Infiltration: �on d 0o x Air Sensible x x Ceiling x / 60] E=Area Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,619 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 x 915 x 2001 Btuh/occ. / 200 sgft/occ. = 915 Receptacle 1.00 x 915 x 0.000 Watts/sgft x 3 41 BtuhMatt o Process 1.00 x 915 x 0.000 Watts/sqft x 3.41 Btuh/Watt = o Infiltration: C 1.00 x 4 840 x 915 x Heigh X 60] 0.00433 = 2 556 Schedule Air Latent Area Ceiling Height ACH _'�W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,471 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 38 of 42 'RESIDENTIAL ROOM COOLING LOAD SUMMARY The Ben Nance Residence Project Title 7/29/2004 Date Room Name HVAC -3 Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 370F E Conduction Area X X X X X X X x X U -Value X X X X X X X X 1,331.0 0.0280 TC 0.8000 777.0 0.0566 184.0 0.3500 108.0 0.4000 50.0 0.0572 24.0 0.3872 18.0 15)x 0.423 DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total 8 275 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Skylight (3620)_(21) (Skylight) hnr (22) (North) FxdGlsWdw Abv. 23 (North) FxdGlsWdw Abv. 24 North FxdGlsWdw Abv. (25) (North) Horiz.Sldr 26 (Northeast) Horiz.Sldr 27 (East) FXdGISWdW Abv. 28 (East) FXdGISWdw Abv. (29) FxdGlsWdw 30 (East) Southeast ( 0.0 XAll, X x x1 X X x x X XL + + + + + + + + + + 7.0 X X x X X X X . x X x 152) X ) X x X X x 0.494 = = = = = = = = __ c 526 ( 0.0 48.0 15 0.30 216 ( 0.0 18.0 15)x 0.423 114 ( 0.0 6.0 15)x 0.423 38 ( 0.0 1 6.0 15) 0.423 38 ( 0.0 1 20.0 48) 0.367 353 ( 0.0 1 20.0 73)x 0.367 536 ( 0.0 1 6.0 73) 0.423 185 ( 0.0 1 6.0 73)X 0.423 185 (I 12.0 1 0.0 62) 0.423 76 Sched. Page Total 2,268 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,338 X 0.500 Wafts/sgft x 3.41 Btuh/Watt = 2,283 Occupants 1.00 X 1,338 X 250 Btuh/occ. / 200 sgft/occ. = 1,672 Receptacle 1.00 x 1,338 x 1.500 Watts/sgft x 3.413 Btuh/Watt = 6,850 Process 1.00 X 1,338 x - 0.000 Watts/sgft x 3.412 gtuh/Watt = 0 Infiltration: �cn ,.00 x Air Sensible � x A 1,338) x Ceiling x ACH / 60] f�,T 37 = 4899 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,5391 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 X 1 338 X 200 Btuh/occ. / 200 Sgft/occ. = 1 338 Receptacle 1.00 X 1 338 X 0.000 Watts/sqft X 3.41 Btuh/Watt = 0 Process 1.00 X 1 338 X 0.000 Wafts/sqft X 3.41 Btuh[Watt = 0 Infiltration: .1.00 X 4840 X 1 33 X Heigh X 60] 0.00433 = 2 570 chedule Air Latent Area Ceiling Height ACH /-\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,908 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 39 of 42 • • 'RESIDENTIAL ROOM COOLING LOAD SUMMARY The Ben Nance Residence 7/29/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: HVAC -3 78°F 115DF 37°F Conduction Area U -Value DETD' Btu/hr X X X X X X X x X 1. Design Equivalent Temperature Difference (DETD) Page Total L� 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FxdGlsWdw Abv. 31 (South) Fxr1r,I%Wrlw (32) (South) FXdGIsWdW 33 (South) FrnchDr 34 (Southwest) FxdGISWdw Abv. (35) (West) FXdGISWdw Abv. 36 (West) FrnchEnt Dr 37 (West) 32 0.423 152 ( 12.0 1 0.0 ( 0.0 X1 X X X x x X x X x + + + + + + + + + + 6.0 X X x x x x x x x x 32) X ) x ) X x x x )x )x )X 0.423 = = = = = = = = = = 81 ( 24.0 1 0.0 32 0.423 152 ( 12.0 1 0.0 32 0.423 76 ( 48.0 1 0.0 62) 0.30 216 ( 0.0 1 6.0 73) 0.423 185 ( 0.0 1 6.0 73)X 0.423 185 ( 37.8 1 10.2 73) 0.301 394 ( ( ( Page Total 1,291 Sched. Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,338 X 0.500 Wattslsgft x 3.412 Btuh/Watt = 2.283 Occupants 1.00 x 1,338 X 250 Btuh/OCC. / 200 sgft/occ. = 1,672 Receptacle 1.00 x 1,338 x 1.500 Watts/sqft X 3.413 BtuhlWatt = 6,850 Process 1.00 x 1,338 x 0.000 Watts/sgft x 3-412 BtuhlWatt = 0 Infiltration: 1.0o x � x i 33 x �1. x � / 60� T Schedule Air Sensible Area Ceiling Height ACH Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,5391 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 338 x 200 Btuh/occ. / 200 sgft/occ. = 1 338 Receptacle 1.00 x 1 338 x 0.000i Watts/sgft X 3.41 Btuh/Watt = o Process 1.00 x 1 338 x 0.000 Watts/sgft x 3.41 BtuhlWatt = 0 Infiltration: chedule x Air Latent x Are 33 x Ceiling Height x ACH 50 / 60] 010N0433 = 2 570 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,908 EnergyPro 3.1 By EnergySoft User Number- 3665 Job Number.. Page: 40 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Ben Nance Residence 7/29/2004 Project Title Date • 0 i Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof R.38.2x14.16 -1 Wall (W.21.2x6.16) Area U -Value DETD1 56.0 35.6 37.0 35.6 37.0 HVAC -4 78°F 115°F 37°F Btu/hr 665 814 532 173 725 1. Design Equivalent Temperature Difference (DETD) Page Total 1 2,9101 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FxdGlsWdw 38 North (Northeast) FxdGlsWdw 40 (Northeast) FxdGIsWdW 41 FrnchDr (42) (East) (East) FxdGlsWdw 43 (South) .._ ... 34 ( 0.0 1 8.0 48 0.367 ( 0.0 x.1 X X x x X x x X X + + + + + + + + +x + .5.3 X X X X x x x X X .15)x ) x )X x )x )x )X )x . _.0.423_= = = = = = = = = = .._ ... 34 ( 0.0 1 8.0 48 0.367 141 ( 0.0 1 5.3 48 0.423 108 ( 0.0 1 5.3 73)x 0.423 164 ( 42.6 1 5:4 73) 0.301 311 ( 0.0 1 20.0 32)X 0.423 271 ( ( ( ( Sched. Page Total 1.0281 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 424 x 0.500 Watts/sqft xA3.413 Btuh/Watt = 724 Occupants 1.00 x 424 X 250 Btuh/occ. / sgft/occ. = 530 Receptacle 1.00 x 424 X 1.500 Watts/sgft x Btuh/Watt = 2,171 Process 1.00 x 424 x 0.000 Watts/sgft XBtuh[Watt = 00 Infiltration: I 1.00 x Air Sensible nsible Area x � x x .L-0.5QACH 1 / 60] 0 = L��3411 `Schedule Ceiling Height -/�,T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,703 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 424 x 2001 Btuh/occ. / 200 sqft/occ. = 424 Receptacle 1.00 X 424 x 0.000 Watts/sgft X 3.41 Btuh[Waft = o Process r 1.00 x ata x 0.000 Watts/sqft X 3.41 Btuh/Watt = 0 Infiltration: I 1.00 x 4840 x 424 x Height x 60] 0.00433 = 703 "`--- chedule Air Latent Area Ceiling Height ACH Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,127 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 41 of 42 ' "RESIDENTIAL ROOM COOLING LOAD SUMMARY The Ben Nance Residence 7/29/2004 is Project Title Date Room Name HVAC -5 Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 370E Conduction Area U -Value DETD' Btu/hr • 9 X (Northeast) 56.0 = 1,309 X FxdGlsWdw 47 35.6 = 1,200 X (South) 35.6 = 641 X 693 37.0 c 918 X 0.423 37.0 = 1,684 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 5 751 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw 44 (Northeast) FrnrhDr (45) (Northeast) FXdGISWdw Abv. 46 (Northeast) FxdGlsWdw 47 (Northeast) Horiz.Sldr (48) FrnchDr 49 (Northeast) (South) FxdGlsWdw 50 (South) Frnchbr 51 (South) 48 0.30 693 ( 0.0 ( 0:0 x1 x X x x x X X x X + + + + + + + + + + 10.0 x X X X x x x x x X 48 ) X ) x )X X x )X )X 0.423 = = = = = = = = = = 203 ( 0.0 1 48.0 48 0.30 693 ( 0.0 1 18.0 48 0.423 365 ( 0.0 1 10.0 48)x 0.423 203 ( 0.0 1 10.0 48)x 0.367 176 ( 24.0 1 0.0 32) 0.30 108 ( 24.0 1 0.0 32)X 0.423 152 ( 48.0 1 0.0 32) 0.30 216 ( . ( Sched. Page Total 2117 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 835 X 0.500 Watts/sgft x 3.4d Btuh/Watt = 1,425 Occupants 1.00 X 835 X 250 Btuh/occ. / 200 sqft/occ. = 1,044 Receptacle 1.00 x 835 x 1.500 Watts/sgft X 3.413 Btuh/Watt = 4,275 Process 1.00 X 835 X 0.000 Watts/sgft x 3.41 BtuhNVatt = 0 Infiltration: �c� x Air Sensible � X Area x Ceiling eight 1.00 x ACH / 60] 37� Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,3911 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 835 x 200 Btuh/occ. / 200 sgft/occ. = 835 Receptacle 1.00 x 835 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 835 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0 Infiltration: �ched,;oo XAirLatent� X Area 83 X Ceiling Height x ACH50 / 60] 0`00433 = 1 458 Fraction ---...- TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,293 EnergyPro 3.1 By EnergySoR User Number: 3665 Job Number. Page: 42 of 42