Loading...
0308-190 (SFD)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 799449 B Dated "�'/1'� Signature of Contractor OWNER -BUILDER DECLARATION ' I hereby affirm, under penalty, of perjury that 1.6m exempt from the Contractor's License Law for the following -reason: ( ) I, as owner.of;the. property, or my. employees with -wages as their sole compensation, will do-'the'work, and the structure'is not interided or offered for sale (Sec. 7044, Business & Professionals Code).' ( ) I, as owner of the property; am exclusively contracting with licensed contractors -to construct the project (Sec. 7044, Business & Professionals Code). i () I am exempt under Section B&P.C.'for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: O I have and will maintain a certificate of consent to self-insure.for.workers' compensation, as ,provided for -by Section 3700 of the Labor Code, for- the performance of the work for,which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance 'of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are; Carrier Policy No. P f• (This section need not be completed if the. permit valuation is for•$100.00 or less): () I certify that in the performance of the work for which this,permit is issued, I shallnot employ any person in any manner so as.to,become subject t6 the workers' compensation laws of California --'and agree that if .1. should become subject to the workers' compensation'pjovislons of Section3700 of the`Labor Code, I shall forthwith comply with thoseprovls ons! Date: Applicant"��•-% > U Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer:to criminal penalties and civil fines up'to $100 000; in' addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions ,set forth -on his application. 1. Each person upon whose behalf this application is made & each person at whose•request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless theCity of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not'commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 -certify that I have read this application and state that the above information, is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorizelrepresentatives of this City to enter upon the above-mentioned property for'insp ctionn_puurrrpposes. Signature (Owner/Agent)�ix. - sl r Date' / PERDd1T # ' BUILDING PERMIT DATE r VALUATION '' q♦ LOT tti�p ii TRACT !� -�t � •. �{/ -��o'f:�fvaYWe.6V ra.. �' V� '+ ..' 'I' �N:✓a7'E ,J \\ JOB SITE SITE ADDRESS u. �aDA APN i 7° �l✓ OWNER CONTRACTOR / DESIGNER / EN INFER ON PEM L� 3.ACOT33 Y•1���IAAJ3V/1.+�tu�iFTd. 3'�a �.rd'+ 9 .G0.77UX692 LA QTM4 A (:.,,A 02253 � Y.,A Q1 13 t T ,' -!A 92253 ('7000117.997.] C..B.14 6613 1 USE OF PERMIT N.7.eb�.uf�;�'ii•�nr1.QJJl. •✓��?�.+s.�au�'i�' � j/ .4193 S- 11'Ta VflhTTA.C1'1ELI CASI'E'AA, 2001 12113C CUSTOM CONSIRUC`rION 4J,93,.09,S .. PORCHIPATAO . •,IL'n dkke•,�s0uy:.E 1i 10N, &JS.NJ 6+6.iL'l9 3,53,094. S0 " _ PIUMMVEE SUMMARY CONSTRUCTION E'ER R0'1 -000.418.000.,s -Io a;S,ss PLAIR CHECK ft1v.; 101. •€10C�3� 318.. ' ,�;t:�g0.'i+I .: , ' 1����c�s��' •�v1.00c��,���a�1'�:hl,Qact.�a. ;. h4I;CHANICt. L FrE 1.�1,-0f3(I.4:?.t•Ot2f2 i 2 U0 �;Ir.EC:�'t'i IdAl Imo' 4 t 01-006-420-00.0 UU 68 ;r PId;IR3 fSTf3i3 3. Q 1-0f9.ti•. 19. 000. 1'i3. Y5 S'.PttONQMt1V014 ' RESID 1091.000-'741-000. W.,cf CJR-r'aDllo O ,4r.1 E' DR. DOVELOPER IMPACT FFR '�7�44S.zt4:t ART IM PUBLIC FL;A.CES-- RF.9lr. 70•006-dct� +G041 `:' �:f�7,'Yk 7j7 RUB -70Th:, COA'r3'TRXIC`.71101;PX $67,pp14{8C�.�69 ��}?p����Fakbt����p.t�••��El!CK� tt ,. ,.. Lfi%.87N'. PRE-PA,11111 Ar�. �lT+7.,' 00,00 DAL:r��'E.1.7�..F�.�t .a17L�.7:rS��VE ��O NOV 0 6.2003 RECEIPT Qq�E D� % } BY DATE FINALED INSPECTO 1 :.. J V /es INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings A Ducts Slab Grade Return Air Steel Roof Deck �O + Combustion Air Exhaust Fans O.K. to Wrap F.A.U. Framing Insulation 1/ Compressor Vents Fireplace P.L. Grills Fireplace T.O. Fans 8 Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final G/ - Final — v'— BLOCKWALL APPROVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING A P 'ROVALS Gas Test Electric Final Waste Lines ter Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Slower Pans O.K. for Finish Plaster Sewer Lateral ..Pool Cover Sewer Connection Encapsulation Gas Piping - - Gas Test Appliances Final Final Utility Notice (Gas) -� ELECTRICAL APPROVALS Temp. Power Pole -Underground Conduit Rough Wiring ' Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) OMMENTS: 's ��� � • / 00'(0(05 �A �o P.O. BOX 1504 Building � ��� '/ � 78-495 CALLE TAMPICO APPLICATION ONLY Address t!. /D Gere/.. LA QUINTA, CALIFORNIA 92253 Owner Mailing Address City Contractor Address City 1ok State Lic.? 4� & Classif. / Zip % 22ATel. 'l f, , Zip eAd ITel. 2 f 4. Lic. If Arcn., tngr., Designer Address Tel. CityI Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I herebyffi arm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (Commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I-] I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) 11 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of properly who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) . 17 I am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company fl Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work. for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., U. after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives sof this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date - Mailing Address City, State, Zip BUILDING: TYPE'CONST._000. GRP. A.P. Number 7/72 eget Description / u Z ZV� .,/ 21 � y l - G.. Project Description /�a�.� s c 44 _ Sq. Ft. No. No. Dw. Size `�� Stories Units New JO Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT of AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing d S.M.I. Grading Driveway Enc. Infrastructure OF CE i TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified. School District This Box For District use only 83=733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760) 398-5909 = Fax (760) 398-1224 - AREA: AMOUNT . LEVEL ONE AMOUNT: LEVEL TWOAMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Date: 11/5/03 Owner's Name: Wayne and Jan Anderson Phone No. 760 777-9921 Project Address: 80-663 Via Pessaro; La. Quinta, CA 92253 Project Description: New Single Family -Home �APN: 772 500 025 Tract #: Lot #'s: Type of Development: Reside 1 r" Commercial Industrial Total Square Feet of Building Area: 4193 _ .. . Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that -he/she is.authorized to son behalf of the owner/developer. Dated: 1 �~j, V ` )�. Signature: ` SCHOOL DISTRICT'S REQUIREMENTS. FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) `Education Code Gov. Code Project M—eementExisting Not Subject to Fee 17620. 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 4193 Amount per Sq.Ft. $2.19 Amount Collected $9182.67 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Marcela Valdez, Facilities Clerk Signature: IPA, dUC16', NOTICE OF 90. DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly. Bill 3081, effective January 1, 1997, requires that this District provide (1) a wri n notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imp sition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notic shall serve to advise you that the'90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or perf nce of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. k1V:c;'inpdoc idevi:ee ieertiticate o.fcompliance roma WilesTO USIi.doc 1/16/03 T N ` J5/19/03 11:31 V17606748577 Z002 r em NAT1ONALTITLE COMPANY ®OC €0. ELI'M + + SUBUiW1SION DEPAWMENT m 02/0!1/20!3 WON Fee:30.N Page t if 4;0" 7 tax Paid Recorded In Official Records . WHEN RECORDED MAIL TO .. C°"'0&ry L. Riverside Mr. &Mrs, Wayne Anderson ' Assessor, County Clerk 6 Recorder TreasureDrive _ Allyn, WA 8524sland MAIL TAX STATEMENT TO: SAME AS ABOVE Inoemmoo em v�■ CiOiP/-�� �see�—�eeeae� DOCUMENT TRANSFER TAX xx Computed on the considetation.or value of property'conveyed; OR iew Computed on the consideration or value less liens or encumbrances-, . C%o remaining at the time of We. , a- a Signature of Declarant or Agent determining tax -Firm Nam GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is heieby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liabili_ty,company ("Grantor."), hereby GRANT(S) to Wayne E. Anderson and Janice E. Anderson, husband and wife ("Grantee'), the real property located_ in the City of La Quinta, County of Riverside, State of California, described as; **as Community Property -. See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of tecoid including, without limitation, the covenants and agmments described in Exhibit "A" attached hereto. Dated: ND LA QUINTA PARTNERS, •LLC, . ` a Delaware, limited liability company By F `Nationwide Realty Investors, Ltd., . + an Ohio limited .liability company r its ma nagingQ/I�I�1fi-mbar BY: • ��-�•-�l�i�-so�ph Z • r�'rer�sn ,• y ::i ' Preeiderr"rt i-- r. I-LM27969. t Description: Riverside, CA. Document- Year. DoclD 2003:55449 Pade 9 of 4 order 00-05-19-2003 11-12-39 AM Comment:,PETER 5/19/03 11:32 1DI7606748577 Z004 Parcel No. 1: Lot 308 (the "Lot") of Amended Tract No. 29894-2 as shown on a`Subdivision Map (the "Map") recorded on 12 7007 . in Book 327; Pages 56 to 88, inclusive, of Maps, in the Office of the Riverside County Recorder. ' EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors; assigns, invitees, licensees and employees, together.with the right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1, The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on 2002, as Instrument No: 2002-7459138 , of Official Records of Riverside County, California (the "Official Records"); J EURTBER RESERVING TIEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shell be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce this right of entry in a court of law, Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel No. 2: NonexchWve easements for access, ingress, egress, drainage, -maintenance, repairs and for other purposes, all as described in the Declaration. SUBJECT TO: 1. Nondelinquent general,, special and supplemental real property taxes and assessments. .. �3-gg5449� Description: Riverside, CA Document -Year. Doc/D 2003.85449 Page: 3 oft t Order: 00-05-19-200311-12-39 AM Comment: PETER M•} 05/19/03 11:33 e17606748577 ZOOS 2, All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without limitation, the Declaration and the Map for Tract No. 29694-2. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration ,and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Sectionl5-1;5 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The. restrictions on use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway owners Association such such and rights which are,set forth in the Declaration defined above, on r ! D STATE OF COUNTY OF ZVY4, 3 public in and Ono►rw t1a_-ate= 2 before rrte, the`unders' notary p ( . for said State, personally appeared 1 •� W f- * ►u- 6 -- or proved to me on the basis of satisfactory evidence) to be the persons) whose executea Warere subscribed to the within instrument and acknowledged to me that �/Ithey execud the same in h%/hear/their authorized capacity(ies), and that by }i AW/their signatures) on the instrument the person(s), or the entity upon behalf of which the persons) aged, executed the instrument. J - WITNESS MY HAND AND OFFICiAL'SEAL. - KATHRYN L HUNTER signature,[SEAL] _ Commissbn f 138 M Notory Pubk - Catlbmlo _ RNewde County •` + , My Cornu E�iree Nov 1.2004 u� I IS iNl 11111 �N �� � ISI i I "6/W3549, Description: Riverside$CA Document-Y ear.Doc1D2003.85449 Page, 4 ot,4 Order. oo-05-19-200311-12-39 AM Comment: PETER M JOB ADDRESSPERMIT NUMBER OWNER FeY\i�Zs'O� \\' BUILDER - ,e\7-k}uAK.tZS This form shall be posted on the job with the. Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be. approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. ... .. Classrf�caUon .::: . .... Contractor ...::.. _. ... _._ ............ ...... ,..: ::: State.:Contractor: s,lacense..: _..........__.. .._ ...... >:;: Workers..Com ensation.lnsurance...::.:..... ... Ctty Bus Hess. .. Company Name Classification (e.g. A, B, C 8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier NamePolicy (e.g. State Fund, CalComp) Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK::. 121.:.... .. �\ . t'i0�� \Z b\ CONCRETE (C 8) 2 C�Yv���\ l �� �`�ol 3 S\ Wr `�� W \l= O`�ic 2 CJ`��o- ��\� \ \ O \ 3\ O ��JS(o ZS .FRAMING .(C 51 .. : " \Wt�OE V��. \�7c�t. ��� 2�� y\3 STRUC.TSTEEC::(C;- .... 1).>.. <>; -Cs MASONRY (C=291 e- OFA PLUMBING (C=36) �, v���A1-- C- 2:>6 \qRck�� �j� V� Oyb' 00\.2.5 13 \ \ v LATH.LAS.TER`: C=35 ,::> .;.;...;<;...:< ; �;:;>::::.:>,I:.:..: DRYWALL (C,9) .... `E t woo wwu., c 5� "� \ �t C��`ML'�\�n�� sCk� ooS - \oye \ o c��l�-x.`12 2 �6 Hvac Ic 20� �cE='��� 2 G 2c-> y\b3� \ "� \ \Y\5�►��rc`. w�.s� ELECTRICAL (C 1Q)C\�C`� _- C \� b►-�i�-moo\�\ �� \\�\�4 C:) C) $ /o .. � Ic3ROQF.(C SHEET:METAL >,,; �.;:. �: �.;::: �.:::.►...:.::::....::.::.. � p � S\o� t� aZaL, G ��{ (o'3��g5 ,�\3\ — s� w � � \-\ o s ��-t5 �o\z� `may e 3 \ � 8 � G GLAZING:3r1\ Na 00 0710 :.;SU�AT��"P" 'Pd .,w' -k L7 (2-2 22 \S \-1 � � \2wL.2�Q5 \c- `.22."Jo SEWAG:E;DISP ,(C 421;::<`::>>: PAINTING'IC. 3 1 `M� LL Yv��orQ� C �3 3���\ 3\ b5 S� �A �� C7�b - 00 \ \oy ooy2� CERAMIC TILE IC 5 1 _ _ AGO �\ S�Oh�cw04� G� �vv -�y�{� $�?.�\lbw}\iL>: V-AS uAL►IO4i C�'bl�$ 0 jt'o bIf CAIN>::;;S::L;;;;;61;:.;;>;;:.;:..:::.;;:: -=bP�L\ C C&I 4E:;\ \fN 06l -'C)000 a $3 �::.;: ;:.:::::::.::.::: 27: ':?< [ ANDS ..A. Gt .: I.;::;.;:.>:.: C�Pc �O 1� (o \Z 1 31 - \ 1 CJ o � 130 CSO �s � s :0Wj Certificate of. Occupancy.0_, , i r + 17E2 OF at y. 'Building &.,Safety Department T1�ti t r • This' Certificate is issued pursuant to the. requirements 10.9 of the California Building , } ,of'Section Code, certifying that,' at the time: of'' issuance,' this structure- was., in ':compliance with the _ provisions ' of the Building Code and the various ordinances -of • the City • regulating building, ° F _�. construction. and/or_use: G I _ �� ' •q '. 7 . �j `tea '.T „.BUILDING ADDRESS: 80-663.VIA PESSARO) u4t.,' •d.♦ • }• .. Y i .{..; t , t ;+• ` �j ny 4 .• I • ', j” !j'• .. J , `• 1 I AA fo € Use'classification: SFD x• F 1 ° � Building Permit No.: 0308-190'' ,'st" Occupancy Group R-3 Type of Construction: V -N LandUse Zone: R -L' Owner of Building: MIM ANDERSON Address: PO BOX 356 '. r City, ST, ZIP: LA QUINTA CA 92253 ' By:..G.SHOWALTER ' Date: 04/20/05 • POST IN A CONSPICUOUS PLACE wtll- 'Date:,, -16/10/2003, The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program hais a'prdval and is p authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LILC (415) 883-5900. EnergyPro 3.1 By EnergySoft 'Job Number. User Number. 3665 TABLE OF CONTENTS Coveir Page", Table of Contents� 2 Form CF -1 RCertificate of Compliance" - 3. Form MF -1 R Mandatory Measures Checklist 6 Form'C-2k Computer Method Summary 8 Form ENV -3 Proposed- Construction -Assembly. 14 HVAC System Heating an,d_Coolirig Loads Summary 15 Room Load Summary. .17 Room Heating Peak Loads 19 Room Cooling Peak Loads, 21 EnlergyPro 3.1 By Energ'y-soft Job Number. User Number. 3665 Certificate of Compliance: Residential (Part 1 of 2) CFAR. The Anderson Residence 10/10/2.003 Project Title Date The Hideaway, Lot 308 La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760)'346-0855 Plan Check Date Documentation Author Telephone Type Computer Performance 15 Field Check Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Wood Total Conditioned Floor Area: 3,615 f? Average Ceiling Height: -11.6 ft Total Conditioned Slab Area: 3-615f? R-21 Wall (W.21.2x6.16) Building Type: 0.057 (check one or more) Slab On Grade Single Family D�ta'ched Addition - 0.756' F-1 Single Family Attached Existing Building Slab On Grade El Multi-Famify Existing Plus Addition 0.756 Front Orientation: (North) dM Floor Construction Type: Slab Floor Number of Dwelling Units: 1.00 0.387 Number of Stories: 1 Raised Floor 0 bUILIJINU 5HELL lNbULATIUN Orientation Area Fenestration 'Exterior Const. Component Frame . Assembly Location/Comments Type Type . U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.057 ExteriorWall. Slab On Grade n/a - 0.756' Exposed Slab w/R-0.0 Perimeter Insulation: Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door Wood 0.387 Exterior Door FENESTRATION -Rharlinn navir-pc Type Orientation Area Fenestration 'Exterior Overhang Side Fins (SF) U-Fa6tor SHGC Shading Yes / No Yes / No Front (North) 20.5 0.60 0.40 Bug Screen nX 1:1 191 Left (East) 90.5 0.60 -0.40- Bug Screen a] El EI [91 Rear (South) 144.0 0.40 0.35 Bug Screen nX E-] 0' FX1 Right (West) '208.5 0.60 0.40 Bug Screen El 11 1-1 191 Front (North) 96.0 0.40 0.35 Bug Screen El F-1 0 [g] Rear (South) 105.5 0.60 0.40 Bug Screen Right (West) 48.0 0.40 0.35 Bucl Screen E] 1:1 0 1:1 1:1 El 0 1:1 El 1:1 1:1 1:1 Q� 0 El El 1:1 0 EJ D Run Initiation Time: 10/10/0308:51:23 Run Code: 1065801083 Energy�ro 3.1 By EnerqySoft User Number. 3665 Job Numbe I r. Page:3 of 25 Certificate of Compliance: Residential (PaIi 2 of 2) CF -1 R The Anderson Residence 10/10/2003 Project Title. Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating'Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or .Type (furnace, heat LEfficiency , Location Piping Thermostat' Location pump, etc:) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments rpntr;;l Figrinni, 80% AFUE — Ducts Attac 4-2 Setback ZONE 1 (Mast r Suite) Central Eurn:;Ce 80% AFUE — Ducts Aftan 4�2 Spthank ZONE 2 (Guest #11LOy'no) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Thermostat Location Type Comments Split Air Conditioner 14.0 SEER Ducts Affic' 42 Spl*i Air Conditioner 14 0 SEER Ducts Affl, n 42 Spthark ZONE 1 (MantprRijite) Setback ZONE 2 (Gup-qt 91 LI WATER HEATING SYSTEMS Rated 1 Tank Energy Fact' 1 Extemal Water Heater Water Heater Distribution #in Input Cap. or Recovery' Standby TankInsul. System Name Type Type Syst. Btu/hr (gal) .-Efficiency Loss R -Value A -0 -Smith FSG -75-230 Small G2S Standard 1 75000 74 0-48 n/2 12 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of.greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.. For instantaneous gas water heaters, list Rated Input and Recovery. Efficiency. Address: 13 Corporate Plaza, Suite #210 REMARKS Newport Beach, CA 92660 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: CJ Mcfadden Title/Firm: South Coast Architect Title/Firm: BREEZE AIR CONDITIONING Address: 13 Corporate Plaza, Suite #210 Address: 75-145 ST. CHARLES PLACE Newport Beach, CA 92660 PALM DESERT, CA 92211 Telephor)V: (949)7 -7022 Telephone: (760) 346-0855 Lic. #: 4Age 10 bolos (signatufe)— ' NJ (date) (sign#re) (dat6) Enforcement a CV cy Name: Title/Firm: Address: Telephone: (sign ature/stamp) (date) — - Run Initiation T*mee 10110103 08@51 .,Run Code* 1065801083- 1 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:4 of 25 Certificate of COM211ance: Residential (Addendum) CF -1 R The Anderson Residence .10/10/2003 ANIL Proiect Title Date "qvSpecial Features a nd Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this ch.eck.list....These items require special written justification and documentation, and special verification to be used with�the performance'approach.. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that other r wise complies is Jdbeu V" Me auequacy or ine 5peciai ju5irrication ano oocumentation sutiminea. Plan Field The DHW System "A.O.Smith FSG -75-230" Energy Factor = 0.480. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "ZONE 1 (Master Suite)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping -Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 280 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 280 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 520 sqft Covered Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify T hermal Mass: 2633 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suite #1/Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2633 sqft Exposed Slab Floor, 4.00" thick at Guest Suite #1/Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 182 sqft Covered Slab Floor, 4.00" thick at Guest Suite #1/Living HERS Required Verification These features, must be confirmed and/or tested bv a certified HERS rater uhder the s6oei-Wsion of a CEC. aooroved HERS proviaer. i ne Mr-11to rater must aocument tne neia vernication ana cliagnostic testing of th se measures on a form CF -BR. Plan Field The HVAC System "ZONE 1 (Master Suite)" includes Refrigerant Charge and Airflow Credit (or a7XV).- A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "ZONE 2 (Guest #1/Living)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EnergyPro 3.1 By EnergySoft User Number. 3665 1 Job Number: - Paqe: 5 of 25 1 0 G Mandatory Measures Checklist: Residential (Pagie 1 of 2) M F A R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an 'asterisk (*) may be supers�ded by more stringent compliance requirements listed on the Certificate of Compliance. When.this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are sho�m elsewhere in the documents or on this che�klist only. DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures [X] -§150(.): MinimumR-19 6iling'insulatic'n. E] § 150(b): Loose fill insulation m anufacturer's labeled R -Value. §150(c): MinimumR-13wal I I insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). []*§150(d): Minimum R-11iraised floor insulation in framed floors orequivilent. E] §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 1XI§118: Insulation specified or installed meets insulation quality standards. Indicatety I pe and form. Fenestration Products, ExteriorDooirs and lnfiltratioh/Exfiltratibn Controls 1. Doors and windows between conditioned and unconditi6ned spaces designed to limit aii leakage. 2. Fenestration products (except field fabricated) have'label with certified U -Factor, , certified:Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked,�nd sealed.' I 50(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door 7 b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gaspilots allowed. Space Conditioning, Water Heating and Plumbing System Measures [X] §110-13: HVAC equipment, water heaters,'showerheads and faucets certified by the Commissi om, I 50(h): Heating and/or 66oling loads calculated in� accordanc6 with ASHRAE, SMACNA or ACCA. 150(i): Setback thermostat on all applicable heating and/or cooling systems. -] F §1500): Pipe and Tank Insulation: X 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be extemally'wrapped with 'ins6lation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-1 6 combined internattexternal insulabon: 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number 3666 Job Number. Page:6 of 25 0 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these. measures regardless o*f the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated Into the permit documents, the. features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION in;tructions: Check or Initial applicable lb�xes or enter NIA linot applicable. DESIGNER ENFORCEMENT $pace -Conditioning, Water Heating and Plumbing System MeaSures: (continued) FX1 I 150(m): Ducts and Fans,4 1. AM ducts and plenums installed, sealed and insulated to meet the re�uirements of the- 1996 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely In conditioned space. Openings shall be sealed with mastic, tape,� aerosol sealant, or other dUct-closuna system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openinbs greater than 114 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and.plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic �a'mpers. 5. Gravity ventilation systems serving conditioned space have eftherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weath4r shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover.. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provi*d;s shielding from solar radiation that can cause degradation of the material. F-1 §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, Weatherproof operating instructions; no electric resistance heating, and no pilot'., 2. System is installed with at least 36" of pip . e between filter and heater for future -solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heat�r for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. FX_1 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118(0: Coal Roof material meet . specified criteria Lighting Measures §150(k)l: Luminaires for general lighting�in kitchens shall have lamps with an efficacy 40 lu'menstwaft or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily,accessible lighting control panel at an enirance to the kitchen. FRI§150(k)2: Rooms with a shower or'bathtub must have either at least one luminaire with lamps �vith an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and -recessed ceiling 6tures a�e IC (insulation cover) approved... Computer Method Summary 1111111061.2; M- ffl;*Gl*-W4%Effi[-1i (P a rt 1 of 3) C -2R Thp Anderson Re-sidenrp Project Title 1111111;&ARTATPIRTO 10/10/2003 Date dbThp Hideawav I ht 308 1 a Quinta __ MARTATP111ir Project Address M;&h RTATFI 1 FiTAT&I WIRMN I. 4 Building Permit # RRFFZF AIR CONDITIONINO fWnE,1613 (760) 346-0855 Documentation Author Telephone Plan Check/Date Comptitpr Perform;anre Compliance Method (Package or Computer) 15 — Climate Zone -Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.96 3.30 0.66 Space Cooling 37.87 36.74 1.13 Domestic Hot Water 7.88 -0.69 Totals 49.71 �,48.62 1.10 0 than Standard: Total Conditioned Floor Area: - Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name I 3,615 ft2 Single Farn De ' tabhed (North) 0 deg 1.00 Floor Area Volume OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt' Ronf 800 n 02R 345 0 WAII 7SR Q 057 0 qn Wall 9F;3 n 0,157 §0 90 Wall 217 0,057 180 90 WMI 444 0.0,57 27n 90 Roof 2815 a_028 345 0 Wall 419 0-057 a 90 Dnnr 32 n 387 0 90 Door 2n n_iA7 0 go Wall 890 0-057 90 gn WAII 386 n,07 ISO go Wall 492 0-057 970 90 2.2 Floor Construction Type: F� Raised Floor FX� Slab Floor Total Fenestration Area: 19.7% - Total Conditioned Volume: 42,084 ft 3 Total Conditioned Slab Area: 3,615 ft 2 # of Units boiar Gains Y/N Form 3 Reference Zone Type rondifinnPri Thermostat Vent Type Hgt. Area .qlpppwnq.qt;it 9 n/a SMhnk n Location / Comments EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paae:8 of 25 1 1111111061.2; M- ffl;*Gl*-W4%Effi[-1i 1111111;&ARTATPIRTO - - M&ARTATI --- __ MARTATP111ir M;&h RTATFI 1 FiTAT&I WIRMN I. 4 fWnE,1613 M&A RYM I KFO&A WZ.-% W Thermostat Vent Type Hgt. Area .qlpppwnq.qt;it 9 n/a SMhnk n Location / Comments EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paae:8 of 25 1 Computer.Method Sunimary *(Part 2 of 3) C -2R The Anderson- R6SIdence 10/10/2003 roject Title 6ate MWFENESTRATION SURFACES U_ Act." Glazin�g Type Location/ # Type.1 Area Factor SHGC Azm. ',Tilt Comm'ents -1- Wlndnw Front (North) 11.5 0 . 600 0-40, f, __m Fleetwood Glazi6a (Lo/F) (1) ZONE 1 2 Window Left (East) 10.0 0.600 0.40 90 _90 Fleetwood Glazing (Lo/E) (1) ZONE I 3 Window Left (East) - -10.0 0.600 0.40 90 90 Fleetwood Glazing (Lo/E) (1) ZONE 1 4 Window Left (East) -4.0 0.600 0.40.' 90 90 Fleetwood Glazinq (Lo/E) (1) ZONE 1 5 Window Rear (South 48.0 0.400 0.35 f 180 '90, Pozzi Clad (Lo/E) ZONE 1 6 Window Right - fflest) 12.5 0.600 0.40 270 90 Fleetwood Glazing (Lo/E) (1Y ZONE 1 _L_ Wbndow Roght Mest) 12.5 0,600 0.40 270 90 Fleetwood Glazing (Lo/E) (1) ZONE 1 8 ' Window Right (West) 12.5 0.600 0.404 270 90,, Fleetwood Glazing (Lo/E) (1) ZONE 1 9- )Window Reght West) 4.5 0,600 0.40 270 90 Fleetwood Glazing (Lo/E) (1) ZONE 1 _1Q Window Right West) 4.0 0,600 0.40 270 '90 Fleetwood Glazing (LoLE) (1) ZONE 1 Window Right (LNest) 4.0 -0.600 0.40 270 90 Fleetwood Glazing (Lo/E) (1) ZONE 1 12 Window Front -(North) 4.5'. 0.600. 0.40 0 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 -ta Window Front (North) .4.5 10-600 0-40 .0., 90, Fleetwood Glazingi (LoLE) (1) ZONE 2 14 Window Front (North) 48.0� 0.400 0.35 0 90 Pozzi Clad (Lo/E) ZONE 2 15 Window Front (North) 7 48.0 0.400 0.35 0 90 Pozzi Clad (Lo/E) ZONE 2 16 Window Left (East) 16.0 0.600 0.40 90 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 17 Window Left (East) 1.5 0.600 0.40 90 90 -Fleetwood Glazing (Lo/E) (1) ZONE 2 18 Window Left (East) 1.5 0.600 0.40 90' 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 19 Window Left (East) 1.5 0,600 --0.40 90 90 Fleetwood Glazing (Lo[E) (1) ZONE 2 20 Window Left (East) 36.0 0.600, 0.40 90 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 2-1 Wi7ndow Left 7 (East) 10.0 0.600-, 0.40' -90 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 22, Window Rear � (South) -4.5 0.600 0.40 180 90'Fleetwood Glazing (WE) (1) ZONE 2 23 Window Rear -(South) 4.5 0.600 180 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 24 Window Rear (South) 20.0 0.600 0.40 180 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 25 Window. Rear (South 4.5 0.600 - 0.40 -,180, -,90 Fleetwood Glazing (LotE) (1) ZONE 2 26 )Window- Rear (South) 36.0 0.600 0.40 .180 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 27 Window Rear - (Souffi) 1-2.0 -6.-6-00 0.40 180 90 Fleetwood Glking (Lo/E) (1) 'ZONE 2 28: Wi�ndow Rear -(South) 1-2.0 0.600 0.40 180 90. Fleetwood Glazing (Lo/E) (1) ZONE 2 1 W 9 Window Rear (South 12.0 0.600 0.40 180 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 INTERIOR AND EXTERIOR SHADING Left Exterior Shade Type SHGC Window Hgt.,;' Wd., Overhang Fin Len. Hgt. LEA i�_E_xt. Dist. Len. Right Fin �Hgt. Dist., Len. H 6t-. 1 Bug Screen 0.76 .0.0 .0.0, 0.0 0.0 0.0, ;,0.0 2 gug Screen 0.76 0.0 0.0 0.0 0.0., '0.0 3 Bug Screen 0.76 0.0 0.01 0.0 0.0, 0.0 0.0 _4 dug screen 0.76 010'_ 0.0 - 0.0 0.0 - 0.0 0.0 5 Bug Screen -0.76 �`0.0' _L� 1. -0. 0 0.0 d.o� 0.0" - Jdug Sdeen 0.76 U . -, 0.0 -Lu 0-0 0.0, 0.0 Bug Screen -.0.76 0.0 0.0- 0.0 0.0 -0.0 0.0 Bug Screen 0.76 1 '0.0 0.0.j 0.0.r. - 0.0 0.0 0.0 9 Bug Screen 0.76 0.0 -,0.0 ;__0_.0 -0.0 . -0. 0 _0.0 10 Bug Screen 0.76 0.0 '0.0 0.0 0.0 0.0 0.0. T1 -i-2 --dug Screen _ffug 0.76", 0.0 0.0 0.0 .0.0 0.0 0.0 Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 �_3 -dug Screen _6ug -0.76 -0.0 _,0.0 0.0 -_0.0 -0. 0 -0.0 T4 Screen 0.76 - 0.0 - 0.0 0.0 0.0 - 0.0 -.0.0- '�5 -i-6 gug Screen _ffug -67-6 -.0.76 _00 -0.0 -00 -__00,_00 -0.0 _00,_00 Screen -0.0 - -0.0 _.o.0 -0.0 17- dug screen 0.76, 0.0 0.0 0.0 0.0 0.0 0.0, 18 Bug Screen _ffug 0.76 0-0 0-0 _70-5 0-0 0-0 0-0 -0 T9 Screen 0.76 0.0 0.6 0.0 0.0 0.0 � 0.0 TO B g Screen 0.76 0.0 0.0 0.01 -0.0, 0.0- 0.0 21. Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0. 0.0 22 Bug Screen -dug 0.76 0.0 0.0 0.0-, 0.0 0.0;�, 23 screen 0.76 1-0.0. 0.0 0.0 0.0 0.0 24 . Bug Screen 0.76 0.0 10.01, _0 0.0 0.0 .0,� 25 Bug Screen -gug 0.76 0.0 0.0. -0.0 0.0 0.0 0.0 0.0 -T6 Screen -,0.76 U 0.0 0.0: 0.0 0.0 .0.0 27 Bug Screen 0.76. 0.0 0.01 -0.0 0.0 0.0 7,0.0 28 Bug Screen 0.76 - 0.0 - '0.0 - 0.0 0.0 0.0 �.,O.O 01,09: Bug Screen -0.76 '0.0 0.0- 0.0, 0.0 0.0 O.OT Run Initiation Time: 1011010308@51@23 Run Coilee- 1065801083 By Energ ySoft User Number. 3665 Job Numb;r. Page: 9 of 25 Computer Method Summary (Part 2 of C -2R The Anderson Residence 10/10/2003 gl�roject Title Date - VWFENESTRATION SURFACES Act. Glazing Type Location/ # Type Area Factor SHGC Azrn. Tilt Comments _M Window Rear -(South) 480 0-400 0 149; 180 90 pn=i Mad (Lo/E) 70NF 2 31 Window Rear (South 48.0 0.400 0.35 180 90 Pozzi Clad (Lo/E) ZONE 2 32 Window Right (West) 10.0 0.600 0.40 270 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 33 Window Right (West) 144.0 0.600 0.40 270 90 Fleetwood Glazing (Lo/E) (1) ZONE 2 34 Window Right .(West) 48.0 0.400 0.35 270 90 Pozzi Clad (Lo/E) ZONE 2 35 Window Right (West) 4.5 0.600 0.40 270 _90 Fleetwood Glazing (Lo/E) (1) ZONE 2 INTERIOR AND- EXTERIOR SHADING Window Overhanq Left Fin �Right Fin, # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. L&t. f�E_xt. Dist. Len. Hgt. Dist. Len. 'Hgt. 30 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 31 Bug Screen 0.76 0.0 0.0 0.0 -0.0 0.0 0.0 , 0.0 32 Bug Screen 0.76 0.0, 0.0 0.0 0.0 0.0 0.0 33 Bug Screen 0.76 0,0 0.0 0.0 0.0 0.0 0.0 3-4 dug Screen 0.76 0.0 0.0 0.0 0.0 - 0.0 0.0 35 Bug Screen 0.76 _U _U 00 00 __u _U Run Inetiateon Time* 10110/0 . 3 08e51 %23 Run Cadir 1065801083 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 10 of 25 Run Initiation Time: 10110/0308:51:23 Run Code: 10658010i3 EnergyPro 3.1 By EnergySoft User Number. - 365 Job Number. Page: 11 of 25 4 Computer Method Summary (Part 3 of 3) Q -2R The Anderson Residence 10/10/2003 Proiact itle Date - WTHERMAL MASS FOR AIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comm e*nts Tole in Mortar 7AQ _Q25 74 -Q�6z /a ZONE 1 / Interior Mass Concrete, HeamMeight — 280 4.00 28 0.98 n/a 0 ZONE 1 / Slab on Grade Concret . HeayMight — 520 4-00', 28 0.98 n/a 2 ZONE 1 / Slab on Grade Tile in Mortar 2,633 0.75 24 0.67 n/a 0 ZONE 2 /Interior Mass Concrete- lrleay)n� 2,633 4.00 28 0.98 n/a 0 ZONE 2 Slab�on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val- Depth Location I Comments Slab Perimeter 49 0.76 00 0 ZONE 1 Slab Perimeter 87 ALM --U 0 ZONE 1 Slab Perimeter 209 -02-6 0.0 0 ZONE 2 Slab Perimeter 21 _O_M __U Q 7QNE 9 HVAC SYSTEMS Heating Equipment Min'imum Distribution Type Type (furnace,'heat Efficiency - and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/aftic, etc.) R -Value Type Comments Central Furnace MxAEuE� bucts in Attic 4.2 Setback, ZONE 1 (Master Suwte� Central Furnace 80% AFUE Ducts in Attic' 4.2 Setback ZONE 2 (Guest #1 /Living) Hydronic Piping Pipe Pipe lhsul� System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (affic, etcj R -Value Type Comments S�fit Air Conditioner 14.0 SEE Ducts in Attic 4.2 Setback ZONE 1 (Master Suite) Split Air Conditioner 14.0 SEER Ducts in-Affic 4.2 Setback ZONE 2 (Guest.#1 /Living) WATER HEATING SYSTEMS lRatedl - Tank Energy Fact! Tank Insul. Water Heater Water Heater Distrib ution #in Input Cap. or Recovery Standby R -Value System Name Type Type' Syst; (Btu/hr) (gal) Efficiency Loss Ext. A.O.Smith FSG -75-230 Small Gas Standard 1 75M0 74 0.48 n/a 12 1 For small gas storage (rated input 75000 Btu/hr), electric resistance �nd heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btuthr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 10110/0308:51:23 Run Code: 10658010i3 EnergyPro 3.1 By EnergySoft User Number. - 365 Job Number. Page: 11 of 25 4 Computer Method Summary (Part 3 of 3) C -2R, The Anderson Residence 10/10/2003 Prolect itie Date, WTHERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heayj8y-eight 182 -AM 98 -a-qa n/a 2 70NF 9 /Rinh nn rrnrlp PERIMETER LOSSES F2 Insulation Type Length Factor R -Val- Depth Location Comments HVAC SYSTEMS,. Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/aftic, etc.) R -Value Type Comments Hydronic Piping' -P. ipe Pipe insul. System Name Length, Diameter Thick. Cooling Equipment Minimum', Duct' Type (air conditioner, Efficiency- - Location Duct Thermostat. Location .heat pump, evap. cooling) (SEER) (aftici etc,)" R -Value Type Comments WATER HEATING SYSTEMS Ratedl,.' Tank Energy Facti 1 Tank Iniul. Water Heater Water Heater, Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type, Syst. tu/hr) (gal) Efficiency Loss (%) Ext. 7 1 For small gas storage (rated input <'= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input,'Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 10/10/0308:51:23 -Run Code: 1065801083 EnergyPro 3.1 By EnerqySoft User -Number 3665 Job Number. Page: 12 of 25 Computer Method Summary (Addendum) C -2R The Anderson' Residence 10/10/2003 ,01,Project Title Date 41 'Special Features and Modeling Assumptions The local enforcemeAt agency should pay special attention to the items specified in this checklist. These items require special written*justification and documentation, and special verification to be used with the performance approach. . The local, ., -' ` enforcement agency determines the adequacy of the justification. and may reject a buildina or desli6n-that otherwise comolies based on the adequacy of the special justification and documentation submitted. 'Plan Field The DHW System "A.O.Smith FSG-75-230"'Energy Factor = 0.4W An EF below 0.58 requires an R-1 2 External Blanket. The HVAC System "ZONE 1 (Master Suite)� must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping.Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 280 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 280 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R),- Verify Thermal Mass: -520 sqft Covered Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(se C -2R).- Verify Thermal Mass: 2633 sqft Tile in Mortar Interior Mass, 6.75" thick at Guest Suite #1/Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2633 sqft Exposed Slab'Floor, 4.00" thick at Guest Suite #1/Living HIGH MASS Design(see C -2R) - Verify -Thermal Mass: 182 sqft Covered Slab Floor, 4.00" thick at Guest Suite #1/Living HERS Required Verification These features must be confirmed and/or tested bv a certified HERS. rater under -the suriervision of a CEC aooroved HERS provider. i ne 11t:Ks rater Must document the field veritication.and_.cliagnostic testing of these measures on a form GF -61R. Field The HVAC System "ZONE 1 (Master Suite)" includes Refrigerant Charge and Airflow Credit (or a TXV). -A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow., 7PIan The HVAC System "ZONE 2 (Guest #1 -/Living)" includes -Refrigerant Charge and Airflow Credit (or a TXV)., A certified HERS. rater must provide verification of the TXV, or measure the Refrigerant Charge and AirfioiW. Run Initiation Time: 10/10103 08:51:23 'Run Code: 1065801083 nergyPm 3.1 By EnergySoft User Number. 3665 Job Number Page: 13 of 25 1PROPOSED CONSTRUCTION ASSEMBLY EN R -VALUE DESCRIPTION E OUTSIDE SURFACE AIR FILM The Anderson Residence, 10/10/20031 2 Membrane, Vaporm Permeable Felt 3 COMPONENT DESCRIPTION 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 ASSEMBLY NAME JR -21 Wall (W.21.24.16) 7 0..37 8 2.60 ASSEMBLY Floor 0.68 INSIDE SURFACE AIR FILM TYPE (check one) Wall uj uj Ceiling Roof FRAMING MATERIAL F Wood z FRAMING % % Framing % TOTAL HC 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM I stucco 2 Membrane, Vaporm Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31, 7 0..37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM R -VALUE THICK- NESS (in.) FRAMING El El 'E1 A El El El 1:1 El 0.170 0.875 0.010 .0.375 5.500 0.625 0.465 21.000 5.445 0.5621 0.562 R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME - R -VALUE 0.170 0.170 0.1751 Or. 175 0.060 0.060 0.466 0.465 21.000 5.445 0.5621 0.562 0.31, 2.63 0..37 0.98 2.60 0.26 0.68 0.680� 0.680 SUBTOITA 23.111 Rc *HEAT CAPACITY (Optional) WALL WEIGHT (lbslsf) SPECIFIC HEAT (Btu/F-lb) HC (A X B) (Btu/F-so x 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29- 0.31, 2.63 0..37 0.98 2.60 0.26 0.68 TOTAL HC NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. x + 0.1323 x. 0.15 I I Rc I - (Fr% /100) 1 Rf Fr0/6 100 ASSEMBLY U -VALUE 3.1 By EnergySoft User Number. 3665 Job Number. I . of 25 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Anderson Residence 10/10/2003 ,or YSTEM NAME FLOOR AREA ZONE 1 (Master Suite) 800 IENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 16,365 Heating System Output per System 72,100 Total Output (Btuh) 72,100 Output (Btuh1sqft) 90.1 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 60.0 Total Output (sqftrron) 200.0 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfmlsqft) 2.001 Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions :ATING SYSTEM PSYC 24.0 OF 0 U ts7id e A �ir 0 cfm 69.4 OF :OOLING SYSTEM 114.1 / 80.3 OF 311, vll� — Outside Air 0 cfm T 78.5/62.9 0 F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COILCOOLINGPEAK 11COILHTG.PEAK CFM I Sensiblel Latent I I CFM FSensible 1 118,001�� F77�� HS26-048/G40UH48B-09OX (4) 39,899 866 72,100 Total Adjusted System Output (Adjusted for Peak Design Conditions) 39,8991 8661 [:::jjA TIME OF SYSTEM PEAK Aug 2 Jan 12 arni 69.4 OF E 1105.00F Heating Coil Supply Fan 1600 cfm 105.0 OF Supply Air Ducts 104.4 OF ROOMS 70.0 OF �% Return Air Ducts 4 78.5 / 62.9 OF M 55.0 / 53.5 OF Cooling Coil Supply Fan 1600 cfm 55.0 / 53.5 OF �o � Supply Air Ducts 55.5 / 53.7 OF 42.5% R.H. ROOM 78.0 / 62.7 OF h Return Air Ducts 4 I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number Paae: 15 of 25 1 16,365 3,195 525 19,832 0 818 992 0 0 0 0 0 0 0 0 1 818 9921 1 118,001�� F77�� HS26-048/G40UH48B-09OX (4) 39,899 866 72,100 Total Adjusted System Output (Adjusted for Peak Design Conditions) 39,8991 8661 [:::jjA TIME OF SYSTEM PEAK Aug 2 Jan 12 arni 69.4 OF E 1105.00F Heating Coil Supply Fan 1600 cfm 105.0 OF Supply Air Ducts 104.4 OF ROOMS 70.0 OF �% Return Air Ducts 4 78.5 / 62.9 OF M 55.0 / 53.5 OF Cooling Coil Supply Fan 1600 cfm 55.0 / 53.5 OF �o � Supply Air Ducts 55.5 / 53.7 OF 42.5% R.H. ROOM 78.0 / 62.7 OF h Return Air Ducts 4 I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number Paae: 15 of 25 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY a EPROJEMT NAME DATE OJ T The Anderson Residence 10/10/2003 S Sy YSTEM NAME FLOOR AREA ZONE 2 (Guest #1/Living) 2,815 lNumber of Systems 21 Heating System Output per System 89,400 Total Output (Btuh) 178,800 Output (Btuh/sqft) 63.5 Cooling System Output per System 58,500 Total Output (13tuh) 117,000 Total Output (Tons) Total Output (Btuh/sqft) 41.6 Tot�l Output (sqft[Ton) 288.7 Air System CFM per System 2,000 Alrflow (cfm) 4,000 Airflow (cfn-dsqft) 1.421 Airflow (cfm/Ton) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above qlven at ARI conditions 24.0 OF 310 Outside Air 0 cfm 69.3 OF :OOLING S 14.1 / 80.3 OF ilo Outside Air 0 cfm 78.7/63.5 0 F 0 111 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD —COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent td CFM I Sensible 1 68,7 1 69,3441 HS26-060/G40UH60C-1 10 (5) 95,679 4,620 178,800 Total Adjusted System Output (Adjusted for Peak Design Conditions) 95,6791 4,6201 E�� TIME OF SYSTEM PEAK Aug 2 Jan 127a]m ream Temoeratures at Time of Heatina Peak) 69.3 OF 0 105.00F Heating Coil Supply Fan 4000 cfm 105.0 OF Supply Air Ducts 104.3 OF ROOMS] 70.0 OF �% Retum Air Ducts "i 78.7/63.50F M 55.0/53.60F 55.0 / 53.6 OF 3.1 By EnergySoft User Number. 3665 Cooling Coil Supply Air Ducts -1, Supply Fan 55.7 / 53.9 OF 4000 cfm 44.1 % R . H. ROOMS 1 78.0 63.2 OF Return Air Ducts Job Number Paae: 16 of 25 62,545 63,040 0 3,127 3,152 0 0 0 0 0 0 0 1 3,1271 1 3,1521 1 68,7 1 69,3441 HS26-060/G40UH60C-1 10 (5) 95,679 4,620 178,800 Total Adjusted System Output (Adjusted for Peak Design Conditions) 95,6791 4,6201 E�� TIME OF SYSTEM PEAK Aug 2 Jan 127a]m ream Temoeratures at Time of Heatina Peak) 69.3 OF 0 105.00F Heating Coil Supply Fan 4000 cfm 105.0 OF Supply Air Ducts 104.3 OF ROOMS] 70.0 OF �% Retum Air Ducts "i 78.7/63.50F M 55.0/53.60F 55.0 / 53.6 OF 3.1 By EnergySoft User Number. 3665 Cooling Coil Supply Air Ducts -1, Supply Fan 55.7 / 53.9 OF 4000 cfm 44.1 % R . H. ROOMS 1 78.0 63.2 OF Return Air Ducts Job Number Paae: 16 of 25 4 E IROOM LOAD SUMMARY PROJECT NAME The Anderson Residence* DATE 10/10/2003 YSTEM NAME 'ZONE 1 (Master Suite) FLOOR AREA 800 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK :.COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM ISENSIBLE LATENT CFM : -SENS-IB I LE ZONE 1 Master Suite, 1 659 16,365 3,195 659 - 1 16 365 3,195 525 19,832 PAGE TOTAL 1 6591 16,3651 3,19511 5251 19,832 TOTAL 1 6591 16,3651 3,1951 525:1 19,8191 EnergyPro 3.1 By EnergySoft User Numb�r. 3665 Job Number. Page: 17 of 25 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 18 of 25 PROJECT NAME T T he Anderson Residence c DATE 10/10/2003 Y y STEM NAMEE ZONE 2 (Guest #llivino) Zo FLOOR AREA 2,815 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK' COILHTG.PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM ISENSIBLE LATENT CFM SENSIBLE, ZONE 2 Guest Suite #1 . /Living 1 2,51 9 62,545 -13,945 2,519.1- 62,545 13,945 1,668 63,040 PAGE TOTAL TOTAL 1 2,5191 62,5451- 13,9455,6681 63,0401 1 2,5191 62,5451 13,945 1 1,6681 63; 01 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 18 of 25 M HEATING PEAK LOADS e Date 10/10/2003 P' ' c� �T �en rson Residence room -information Design Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 800 Outd6or Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF, R-38 Roof (R.38.2xl4.16) - surface Area 800.0 x X x x x X, x x x x x x X x x X x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x X, x x x x x x x x x 46.0 1,031 R-21 Wall (W.21.2x6.16) 1,182.5 0.0566 46.0 3,080 Fleetwood Glazing (Lo/E) (1) 85.5 0.6000 46.0 2,360 Pozzi Clad (Lo/E) 48.0 0.4000 46.0 883 Slah -On-r�radp perimeter 136.0 45.5 6,188 Items shown with an asterisk denote conduction through an interior Infiltration: 1.00 x Sensible x Fraction to another mom. x Coiling Height ACH 160] Page Total: AT TOTAL HOURLY' HEAT LOSS FOR ROOM 19 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 19 of 25 ROOM HEATING PEAK LOADS I ec Date Tit% Pte �n rson 10/10/2003 T , Residellce 11koom Information Desicin Conditions Room Name Guest Suite #1/Living Time of Peak Jan 12 am Floor Area 2,815 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb,Temperature 70OF Conduction surface Area Area x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x x U --Value X x x x x x x x x x x x x x x x x x x X x x x X x x x x x x x x x x x x x x x X' AT OF Btu/hr R-38 Roof (R.38.2xl4.16) 2,815.0 0.0280 46.0 3,626 R-21 Wall (W.21.2x6.16) 2,186.5 . 0.0566 46.0 5,695 Fleetwood Glazing (Lo/E) (1) 339.5 0.6000 46.0 9,370 Solid Wood Door . 52.0 0.3872 46.0 926 Pozzi Clad (Lo/F) 240.0 0.4000 46.0 .4,416 Slab -On -Grade perimeter 230.0 45.5 10,465 Items shown with an asterisk denote conduction through an interior Infiltration: 1.00 x Sensible x Fraction to another room. x Ceiling Height ACH 60] Page Total: AT 34.4991 TOTAL HOURLY HEAT LOSS FOR ROOM 63,040 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number Page: 20 of 25 LA E RESIDENTIAL ROOM COOLING LOAD SUMMARY The Anderson Residence 10/10/2003 Project Title Date Room Name Master Suite Design Indoor Dry Bulb Temperature: 780F 0 Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 370F Conduction Area U -Value DETD'. Btu/hr x x x x x x x x x 56.0 = = = = 1,255 35.6 2,384 - 37.0 1,898 37.0 710 FxdGisWdw (21) (West) FxdGIsWdw (22) (West) FxdGIsWdw (23) (West) Vert.Sldr (24) (West) FxdGIsWdw (25) (West) 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGIF Area SGIF SC Btu/hr FxdGisWdw (27) (North) Vert Sldr (28) (East) Vert.Sldr j29j (East) FxdGisWdw (30) (East) FmchDr (20) (South) FxdGisWdw (21) (West) FxdGIsWdw (22) (West) FxdGIsWdw (23) (West) Vert.Sldr (24) (West) FxdGIsWdw (25) (West) 0.0 x x x x x x x x x x I + 1 + 1 + 1 + 1, + 1� + 1 + 1 + 1 + A, + ' 11.5 x x x x X X x x X x 15)X )x )x 0.44 = = = = = = = = 77 0.0 10.0 7 0.445 325 0.0 10.0 73)x 0.445 325 0.0 4.0 73)x 0.445 130 0.0 48.0 32)x 0.390 598 0.0 12.5 73)X 0.445 406 0.0 12.5 73)x 0.445 406 0.0 12.5 73)X' 0.445 406 0.0 4.5 -4.0 7 0.445- 146 0.0 73)x 0.445 130 Sched. Page Total 2.9511 Internal Gain Frac. Area Heat Gain I Btu/hr- Liqhts 1.00 800 0.50� Watts/sqft x 3.41 Btuh[Waft 1,365 Occupants 1.00 X 800 X _125� Btuh/occ. sqft/occ. 613 Receptacle 1.00 x 800 x _g.00 Watts/sqft x BtuhfWaft 0 Process 1.00 x 800 x 0.000 Watts/sqft x BtuhfWatt 0 Infiltration: x x x I x 60] Air Sensible Area Ceiling Height ACH �T Fraction FoTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 1 36�5] Sched. Latent Gain Frac. Area Heat Gain Btu/hr OccuDants 1.0 X 800 X 225 Btuh/occ. sqft/occ. Receptacle 1.00 x 800 x 0.000 Wafts/sqft x BtuhfWaft = Process 1.00 X 800 X 0,000 Wafts/sqft x Btuh/Waft = Infiltration: F- -1,001 x x x x 60] Schedule Air Latent Area Ceiling Height ACH Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,1951 lEnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paqe: 21 of 25 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Anderson Residence 10/10/2003 Project Title Date Room Name Master Suite Design Indoor Dry Bulb Temperature: 780F 0 Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: :V0F Conduction Area U -Value DETD Blu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk denote conduction through an interior surface to another room. Shaded Uns'haded Solar Gain Orientation Area ' SGIF Area SGF' Sc Btu/hr FxdGIsWdw (iQ) (LA/est) .0,0 x 15 + 4.0 x 7 )X 0.445 136 x x )x x x -)x x + x X, )x x + x X. x .)x x + x -J )x x + x )x x + X -X x .)x Sched. Page Total Internal Gain Frac. Area, Heat Gain Btu/hr Lights 1.06 800 x 0.500 Watts/sqft, x 3.41d'Btuh/Waft 1,365 Occupants 1.00 X 800 X 255 Btuh/occ. sqft/occ. 613 Receptacle 1.00 X 80 X 0.000 Wafts/sqft x BtuhMaft 0 Process 1.00 x 800 x 0.000 Watts/sqft x Btuh/Waft 0 Infiltration: x Air Sensible x Area x Ceiling Height x ACH /601 Fraction [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,3651 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x X, 125 l3tuh/occ. I sqft/occ. Receptacle 1.00 x x 0.000 Watts/sqft x BtuhMaft = Process 1.00 x 0-000 Wafts/sqft x Btuh/Waft = Infiltration: chedule x Air Latent x Area Ceiling Height x ACH 601 4�'W Fraction FTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,195 EnergyPro 3.1 By EnirgySoft User Number. 3665 Job Number.. Page: 22 of 25 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Anderson Residence 10/10/2003 Project Title Date Room Name Guest Suite #1/Living Design Indoor Dry Bulb Temperature: 780F 0 Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 370F Conduction Area U -Value DETD 1 - Btu/hr x (North) 56.0 = 4,415 x FrnchDr (32) 35.6 = 4,408 x (East) 37.0 = 7,537 x CsmntWdw (8) 35.6 FxdGIsWdw (9) 717 x 48.0 37.0 0.390 3,5521 x x x x 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. I Shaded 'Unshaded Solar Gain Orientation Area SGF Area SGF' Sc Btu/hr FxdGIsWdw (35) (North) FxdC,IqWdw (16) (North) FrnchDr (31) (North) FrnchDr (32) (N orth) CsmntWdw (4) (East) FxdGIsWdw (5) (East) FxdGIsWdw (6) (East) FxdGIsWdw (7) (East) CsmntWdw (8) ast) FxdGIsWdw (9) 281 0.0 x x x X x x X x x X 1 + 1 .+ 1 + 1 1, + 1 + . 1 + 1 + 1 + 11 + 4.5 x X x X X x X X X x 1 )X )X 0.445 = = = = = 30 0.0 4.5 1 0.445 30 0.0 48.0 15)X 0.39 281 0.0 48.0 15)x 0.390 281 0.0 16.0 73)x 0.445 520 0.0 1.5 73)X 0.445 49 0.0 1.5 73)X 0.445 49 0.0 1.5 73)X 0.445 49 0 36.0 73)x 0.445- 1,170 10.0 73)x 0.445 325 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Liqhts 1.00 2,815 0.500 Watts/sqft x 3.41 Btuh/Watt 4,804 Occupants 1.00 X 2,815 X 255 Btuh/occ. / sqft/occ. 2,156 Receptacle 1.00 x 2,815 X 0.000 Wafts/sqft x BtuhMaft 0 Process 1.00 x 2,815 x 0.000 Wafts/sqft x BtuhMatt 0 Infiltration: x X 1 28151 X x 60] Air Sensible Area Ceiling Height ACH Z\ T Fraction [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,54J Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.0 x x 225 Btuh/occ. sqft/occ.' Receptacle 1.00 x x 0.000 Watts/sqft x BtuhMaft = Process 1.00 x x 0,000 Watts/sqft x Btuh/Waft = Infiltration: XE 4,8401 X x x /601 1 o.004 Air Latent Area Ceiling Height ACH Fraction FTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 13,9451 lEnergyPro 3.1 By EnergySoft User Number. 3665 Job Number Page: 273.f 25 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Anderson Residence 10/10/2003 Project Title Date Room Name Guest Suite #1/Living Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 780F 115 0 F 370F Conduction Area U -Value DETD Btu/hr x x x x x x x x x 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior sufface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SIC Btu/hr FxdGIsWdw (33) (South) FxdGisWdw (34) (South) CsmntWdw (10) (South) FxdGIsWdw (11) (South) CsmntWdw (13) (South) FxdGIsWdw (15) (South) FxdGisWdw (16) (South) FxdGisWdw (17) (South) FrnchDr (18) (South) FrnchDr (19) (South) 0.0 x X x x x x x x X x 1 + 1 + 1 + 1 + 1, + 1 + 1 + 1 + 1 + + 4.5 x' x X x X x x X X x 32)X )x )x )X 0.44 = = = = = = = = —' = 64 0.0 4.5 3 0.445 64 0.0 20.0 3 0.445 285 0.0 4.5 32)x 0.445 64 0.0 36.0 32)x 0.445 513 0.0 12.0 32)X 0.445 171 0.0 12.0 32)X - 0.445 171 0.0 12.0 32)X 0.445 171 0.0 48.0 32)X 0.390 598 1 0.0 1 0.390 1 598 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Liqhts 1.00 2.815 : x 0.500 Wafts/sqft x 3.41� Btuh/Watt 4,804 Occupants 1.00 X 2,815 X 255 Btuh/occ. I scift/occ. 2,156 Receptacle 1.00 x 2,815 X 0.00 Watts/sqft x BtuhfWatt 0 Process 1100 x 2,815 x 0.000 Watts/sqft x BtuhfWaft 0 Infiltration: x Air Sensible x Area x Ceiling Height x ACH 60] nJ Fraction F_ TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62,545� Sched. Latent Gain Frac. Area Heat Gain Btuffir Occupants x x 225 Btuh/occ. sqft/occ. Receptacle 1.00 x x 0.0001 Watts/sqft. x BtuhMatt = Process 1.00 x x 0.00 , Watts/sqft x BtuhfWaft = Infiltration: chedule x Air Latent x Area x Ceiling Height x ACH 60] 1n1W Fraction ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 13,945] lEnergyPro 3.1 By EnergySoft User Number 3665 Job Number. Page: 24 of 25 0 9 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Anderson Residence 10/10/2003 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Suite #1 /Living 780F 115 0 F 370F Conduction Area U -Value DETD Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF' Sc Btulhr FxdGIsWdw (12) Mest) 0.0 x 1 + 10.0 x 7 ) X 0.44 = 325 SIrIqC,IqDr (14) (West) 0.0 x I + 144.0 X 7 )x 0.445 = 4,681 FrnchDr (1) (West) 0.0 x I + 48.0 x 7 ) X 0.390 = 1,365 Vert.Sldr (2) (West) 0.0 x 1 + 4.5 x 73)x 0.445 = 146 x + X )x x + x -)x x + x -)x x + x -)x x + x )X x xE--1)x,-I=I Sched. - Page Total 6.5171 Internal Gain Frac. Area Heat Gain Btulhr Liqhts 1.00 2,815 0.500 Watts/sqft' x 3.41 BtuhMaft 4,804 Occupants 1.00 X 2,815 X 255 l3tuh/occ. / sqft/occ. 2,156 Receptacle 1.00 x 2,815 X 0.000 Watts/sqft x BtuhMaft 0 Process 1.00 x 2,815 x 0-000 Wafts/sqft - x BtuhMaft 0 Infifltration: x Air Sensible x I Area x Ceiling Height x ACH 60] ��T Fraction FTOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 62.5451 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1 0 x x .225 Btuh/occ. sqft/occ. Receptacle 1.00 X x 0.0001 Watts/sqft x BtuhMatt Process 1.00 x x 0.000 Watts/sqft x BtuhMaft Infiltration: 1.0 x ent x Area x Ceiling Height x ACH 60]. &W Fraction 170TAL HOURLY LATENT HEAT GAIN FOR ROOM 13,945.1 lEnergyPro 3.1 By EnergySoft User Number. 3865 Job Number Page:25of25 TITLE 24 REPORT. Title 24' Report for:,-. ",The Anddrson'Residence (Guest.House) The, -,H i-de'away, -Lot 368 La Quinta,; CA 92253 -,rqj6ct Designer:--;,,' oast.Architect� ,.South C 13 Corporate Plaza, Suite.#210 'Newport Beach, CA 92660 (949) 720-702Z,,� Re'ort Pre0ared By:' P Gi6a Roge, BREEZE'AIR CONDITIONING 75-145 ST.CHARLES PLACE PALM DESERT, CA 92211. e _'(760) 346-08551— Job Number: 1�1 11 1:J" -.Date:' 10/9/2003. The EnergyPro computer program has been , used to perform the callculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both'the Residential and Nonresidential 2001 Building Energy Efficiency Standards.. -This program devel6'ped by EnergySoft, LLC,(415) 883-5900. EnergyPro 3.1 By Ener6ysoft Job Num-ber: User Number. 3665 TABLE OF CONTENTS 4 - Cover Page 1 Table of Content s 2 Form CF -1 R Certificate of Compliance 3 Form MF-IR'Mandatory Measures Checklist' 6 Form C -2R Computer Method Sum"mar' 8 Form ENV -3 Proposed Construction Assembly 12 HVAC System Heating and, Cooling, Loads Summ' 13 Pry Room Load Summary" 14 Room Heat' g Peak Loads, 15. in 'Room Cooling Peak Loads., 16. J E;�.rgyPro 3.1 By EnergySoff Job Number. User Number: 3665 t I Certificate of Compliance: Residdintial (Part 1 of 2) CF -1 R The Anderson Residefte (Guest HoOse) 10/9/2003 Project Title Date The Hideaway, Lot 308 La Quinta Project Address Building Permit# .BREEZE AIR COND)TIONING 346-0855 Plan Check Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone 'Enforcement Agency Use Only GENERAL INFORMATION Wood Total Conditioned Floor Area: 578 f? �'_Averageteiling Height: 8.5 ft Total Conditionea Slab Area: 2 1 1 578ft 01 Building Type. Exterior Wall (check one or more) Wood FRI single Family Detached [J'Addition El Single Family Attached 'E'xisting Building El Multi -Family Existing Plus Ad-ditic'n" Front Orientation: (North) 0 deg Floor Construction Type: Slab Floor Number of Dwelling Units: 1.00 Number of �tories: _]�Raised Floor F_ L-1 0 tSUILUINU 5HELL IN51LILATION Orientation Area A Fenestrati n 0 Exterior Const' Component Frame. Assembly, Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6:16) Wood 0.057 Exterior Wall Solid Wood Door Wood 0.3V Exterior Door Slab On Grade n/a 0756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.156 Covered Slab w/R-O'.0 Perimeter Insulati on Bug Screen [91 - El 1:1 0 ETEI 1:1 1:1 7. FENESTRATION 11 - Ahnelinn nowit-acm - Type Orientation Area A Fenestrati n 0 Exterior Overhang Side Fins (SF) U -Factor SHGG Shading Yes / No Yes / No Front (North)— 20.0 0.60 0.46 Bug Screen a] El 1:1 0 Rear (South) 48.0 0 .40 0.35 Bug Screen Right (West) 30.0 0.60 0.40 Bug Screen [91 - El 1:1 0 ETEI 1:1 1:1 7. El El 1-1 1:1 El El' F] El F _1 El El El 1:1 El 1:1 1:1 EY 1:1 El El 1:1 1:1 El 1:1 4 El 1:1 D El Run Initiation Time: 10/09/63 11:28:35 - Run Code:' 1065724115 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number- Page:3 of 16 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R The Anderson Residence (Guest House) 10/9/2003. Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping. Thermostat Location pump, etc.) (AFUE/HSPF) (ducts, attic, etc.).. R -Value Type' Comments ('Pntrnl Furnnm- 80% AFUE Ducts Attic 4-2 Spthack Guest Suite #2 Cooling Equipment Minimum - 'Duct Type (air Conditioner,- Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type. Comments Split Air Conditioner 14.0 SEER Ducts Attic 42 Spthnrk Rated 1 WATER HEATING SYSTEMS Tank Energy FacO External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type' Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A-0-Smqth FSG -5171-924 Small Gas Recircrrime+Temp— I 4n nnn 50 0-55 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btuthr), electric resis . tance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS UVW1rLIANUr_ b I A I r_MIZN I This certificate of compliance lists the building features and performance specificatidris ne6ded to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: -Gina Rose Title/Firm: South Coast Architect Title/Firm: BREEZE AIR CONDITIONING Address: 13 Corporate Plaza, Suite #210 Address: 75-145 ST. CHARLES PLACE Newport Beach, CA 92660 -PALM DESERT, CA 92211 Telephone: (949) 720-7022 Telephone: (760) 346-0855 Lic. #: (0/a (signature) (date) (signatuXr da Pe) Enforcement Agency Name: Title/Firm: Address: Telephone: (sianature/starrID) (date) JEnergyPro3.1 By EnergySoft User Number: 3665 Job Number: Page:4 of 16 Ceddicate of Compliance: Residential (�ddendum) CF -1 R The Anderson Residence (Guest House) 10/9/2003 ift project Title Date Special Features and Modeling Assumption's The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the perforriia'nce approach. The local . enforcement agency determines the adequacy of the justification, and may reject a building or design that,otherwise complies )asea on ine aaequPcy or tne speciai JUSUTIcation ana aocumentation submittea. Plan Field The DHW System "A.O.Smith FSG -50-224" Energy Factor 0.550. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the s ion.of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing=e measures on a form CF -6R. —Fia—n-7 Field The HVAC System "Guest Suite #2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge,and Airflow. Run Initiation Time: 10/09/03 11:28:35 Run Code: 1065724115 EnergyPro 3.1 By EnergySoft - User Number. 3665 Job Nu'mber: -Page:5 of 16 0 Mandatory Measures Checklist: Residential (Page 1 of 2) M F-1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be cor�sidered by all parties as minimum component performance specifications for the mandatory measures -whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or initial applicable boxes or''enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures [X] *§ f50(a): Minimum R-1'9 ceiling insulation.' §150(b): Loose fill insulation manufacturers label�d R -Value. FV -1 I 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame, walls (does 1^1 not apply to exterior mass walls). E]*§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, 'water vapor tra nsmission rate no E] greater than 2.0 pern-dinch. [XI §118: Insulation specified or installed meets insulation quality standards. Indicate type a6d form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification' 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate.,Zone's 14 and 16 only. §150(f): Special infiltration barrier installed tocomplywith Section 151 meets Commission qualitystand airds. 'Appliances §150(e): Installation of Fireplaces,Decorative,Gas and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed'. Space Conditioning, Water Heating and Plumbing System Measures [X] § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 1 50(h): Heating and/or cooling loads calculated in accordance with ASH RAE, S MACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems., FXJ §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energ� Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 o1r greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-1 2 external insulation or R-1 6 combined intemal/extemal insulation. 4. All buried or exposed piping insulated irf recirculating sections of hot water syste�ns. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. iEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:6 of i�6� I MandatorwMeasures Checklist: Residential (Page 2 of 2) , MF -1 R NOTE: Lowrise residential buildings subject to the Star�dards must contain these measures regardless of the compliance approach used. Items marked with an - asterisk (-) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or Initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing Sygteirn,Meas6res: (6ontinu,ed) IFV_1 I 150(m): Ducts'and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape,'aerosol sealant,.or other duct-closu.re system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or,tape is L�sed to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavitiei shall not be used for conveying conditioned air. joints and seams of duct systems and.their components shall not , be sealed with cloth back rubber adhesive duct tapes unless.such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional aiea of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape Is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers., 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or paint;d with a.coating that is water retardant and provides shielding from solar radiation that can cause degradation of.the material. F—] §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools �r outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. V F X11 §115: Gas fired central f6mac'es, I pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btuthr) §118 (f): Cool Roof material meet specified criteria Lighting Measures RX §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lu I menstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. - IX -1, §150(k)2: Rooms with a shower or bathtub must have either at least one luminairei with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement' allowed in Section 150(k)2.; and recessed 6eiling fixtures are IC (insulation cover) approved., Computer Method Summary (Part 1 of 3) C -2R Ihp-.Ande son Residence (Gipst House) i 1 o/gigno, AM Project Title Date W-The-ffid lot 308 La Quinta Project Ad Building Permit # BREE7F AIR CONDITIONING (760) 346-0855 Documentation Author Telephone Plan Check/Date ()M erformance 15 1 Field Check/Date C mpliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.90 3.68 0.22 Space Cooling 56.42 58.84 -2.42 Domestic Hot Water 33.17 30.49 2.68 Totals 93.49 93.01 0.48 better than Standard: Total Conditioned Floor Area: 578 ft 2 Floor Construction Type: [-I Raised Floor FRI Slab Floor Building Type: Single Farn Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 17.0% 3 Number of Dwelling Units: 1.00 Total Conditioned Volume: 4,913 Number of Stories: - 1' . . Total Conditioned Slab Area: 578 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area 'Volume Units —Zone Type Type — Hgt. Area -Gues - SM 491 1 00 CrinfiffinnPri --Setback n a 0 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Roof 578 —0-02.8- — 345 0 V-Vall 184 0 057 n 90 Wall__ 1 z 0 057 go 90 -Wall 132 —O -Q57- 180 90 DjaQL— 24 0,387 180 -Wall— _4654 n 057 270 90 0 ooiar Gains Y/N Form 3 Refere I nce Location/ Comments X El R-38 Roof (R_38_2x14_16) Guest Suite #9 X E 1 R-21 wan ON 21 2x6.16) Guest quit 2 El R-21.Wall (W -21-2x6.1.6) r.11P tRid 9 El _2x6_16 A3ues El soiad wood poor L a X 1:1 R-21 Wall (W.21 -2x616) jG, lest S, 9 Run Initiation Time: 10/09103 11:28:35 RunCode: 1065724115 �.l By EnergySoft User Number: 3665 Job Number. Page:8 of 16 Computer Method Summary (Part 2 of 3) C -2R The Anderson Residence (Guest House) 10/9/2003 Adilk Prolect Title Date FENESTRATION SURFACES u- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt -I- Window Front ----(Rojift) 10.0 0600 040 a AQ Fleatmod Gla7ffinq (Ln/F) (1) ----Comments -G-ueqf Suite A19 2 Window Front (North) 10.0 0.600 0.40 0 90 Fleetwood Glazing (Lo/E) (1) Guest Suite #2 3 Window Rear (South 48.0 0.400 0.35 180 90 Pozzi Clad (Lo/E) Guest Suite #2 4 Window Right (West) 30.0 0.600 0.40 270 90 Fleetwood Glazing (Lo/E) Guest Suite #2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 0.0 0.0 0.0 0.0 -0.0 0.0 T gug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Bug Screen -4 -dug 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 7 - Run Initiation Time: 10/09103 11:28:35 Run Code: 1065724115 EnergyPro 3.1 By EnergySoft User Number: 3665, Job Number: Page:9 of 16 0 ItEMARKS Run Initiation Time: 10/09/03 11:28:35 Run Code: 1065724115 En -r yPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 10 of 16 Computer Method Summary (Part 3 of 3) C -2R The Anderson Residence (Guest House) 10/9/2003 Adik Prnlact Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form -3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation, Type Length Factor R -Val- Depth Location Comments -alal� kr. 3 a76 0.0 0 Guest Suite #2 .S1ab-EefjrrLeteL- 60 —0-M --QD 0 Guest Suite #2 HVAC SYSTEMS Heating Equipment Minimurn Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location pump, etc.) (AFUE/HSPF)(ducts/aftic, etc.) R -Value Type Comments -Central Furnace 80% XFUE Ducts Attic 4.2 Setback Gu I est Suite #2 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location buct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.0 SEE Ducts in Attic 4.2 Setback Guest Suite 2 WATER HEATING SYSTEMS. Ratedl Tank Energy Fact! 1 Tankinsul. Water Heater. Water Heater. Distribution #in Input Cap. or Recovery Standby R -Value System Name -Type Type Syst. (Btu/hr) (gal) Efficiency Loss Ext. A.O.Smith FSG -50-224- Small Gas Recirc/Time+Temp-- 1 40,000 50 0.55 n/a 12 For small gas storage (rated input 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. 0 ItEMARKS Run Initiation Time: 10/09/03 11:28:35 Run Code: 1065724115 En -r yPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 10 of 16 Computer Method Summary (Addendum) 9-2R The Anderson Residence (Guest House)- 10/9/2003 MkProject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies aasea on tne a0equacy of tne special justification and clocumentation Submitted. Plan Field The DHW System "A.C.Smith FSG -50-224" Energy.Factor 0.550. An EF below 0.58 requires an R-12 E�ternal B lanket. HERS Required Verification These features must be confirmed and/or tested b . y a certified HERS rater under the s sion of a CEC approved HERS provider. The HERS rater Must document,the field verification and diagnostic testing=se measures on a form CF -6R. --ptan The HVAC System "Guest Suite #2" includes Refrigerant Charge and Airflow Credit (or a TXV).'A.certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 10/09/03 11:28:35 Run Code: 1065724115 EnergyPro 3.1 By EnergySoft User Number: 366.5 Job Number: Page: 11 of 16 )ROPOSED CONSTRUCTION ASSEMBLY ROJECT NAME The Anderson Residence (Guest House) ENV -3 DATE 10/9/2003 COMPONENT DESCRIPTION DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 ASSEMBLY NAME IR -21 Wall (W.21.2x6.16) 0.31 7 0.37 8 2.60 ASSEMBLY Floor UNSIDE SURFACE AIR FILM 0.680 23.111 TYPE (check one) Wall W. Ceiling Roof 14.81 FRAMING MATERIAL Wood 0 z FRAMI NG- % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) I 0000010111MI-D DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 L 0.68 UNSIDE SURFACE AIR FILM I 0000010111MI-D -THICK- NESS (in.) FRAMING El El El TX Q E] 0:170 0.875, 0.010 0.375 5.500. 0.625. 0.060 1.69 0.465 21.000 5.445 0.562 -SUBTOTA I 0000010111MI-D R -VALUE Rc Rf *HEAT CAP ACITY (Optional) CAVITY. R-VALLIE (Rc). WOOD FRAME R -VALUE A.170 0:170 -0.175 0.175 0.060 0.060 1.69 0.465 21.000 5.445 0.562 0.562 0.31 2.63 0.37 .0.98 2.60 0.26 0.68 0.680 0.680 23.111 7:56'1 R -VALUE Rc Rf *HEAT CAP ACITY (Optional) WALL WEIGHT (lbsisf) SPECIFIC - HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf) 0.0433 x 8.461 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 .0.98 2.60 0.26 0.68 14.81 TOTAL HC NOTE: Weight and Specific Heat values for materials penetrate� by wood framing inclyde the effects of the framing members. 0.0433 x '0. 1323'-] x F o.15 1 / Rc 1 (Fr0/6 100) 1 / Rf 'Fr0/6 / 100 ASSEMBLY U -VALUE 'age: 12 of 16 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Anderson Residence (Guest House) 10/9/2003 SYSTEM NAME FLOOR AREA Guest Suite #2 578 EATING SYSTEM 24.0 OF *7 Outside Air 0 Cfrn 69.2 OF 69.2 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I 'Sensible 1 12,50�O� F777;;;� HS26-024/G40UH24A-045X (2) 19,863 608 36,000 Total Adjusted System O�.tput (Adjusted for Peak Design Conditions) 1 19,8631 608] TIME OF SYSTEM PEAK F Aug 2 prn] Jan 12 arni 105.0 OF Heating Coil Supply Fan 800 Cfm 105.0 OF 310� Supply Air Ducts 7� 104.2 OF ROOMS 70.0 OF h Return Air Ducts 'I 1COOLING SYSTEM PSYCHROMETRICS (Airstream TemDeratures at Time of Coolina Peak) I 14.1 / 80.3 OF Outside Air 0 Cfm 78.7/63.1 0 F 78.7/63.10F M 55.0/53.60F Cooling Coil Supply Fan 800 cfm 55.0 / 53.6 OF 4 Supply Air Ducts Is 55.7/53 . 8 OF 43.1% R.H. ROOMS] 78.0162.9 OF *1( ;0 1 � Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Pane: 13 of 16 1 11,364 14,096 0 -3A 568 705 0 0 0 01 0 0 0 0 5681 705, 1 12,50�O� F777;;;� HS26-024/G40UH24A-045X (2) 19,863 608 36,000 Total Adjusted System O�.tput (Adjusted for Peak Design Conditions) 1 19,8631 608] TIME OF SYSTEM PEAK F Aug 2 prn] Jan 12 arni 105.0 OF Heating Coil Supply Fan 800 Cfm 105.0 OF 310� Supply Air Ducts 7� 104.2 OF ROOMS 70.0 OF h Return Air Ducts 'I 1COOLING SYSTEM PSYCHROMETRICS (Airstream TemDeratures at Time of Coolina Peak) I 14.1 / 80.3 OF Outside Air 0 Cfm 78.7/63.1 0 F 78.7/63.10F M 55.0/53.60F Cooling Coil Supply Fan 800 cfm 55.0 / 53.6 OF 4 Supply Air Ducts Is 55.7/53 . 8 OF 43.1% R.H. ROOMS] 78.0162.9 OF *1( ;0 1 � Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Pane: 13 of 16 1 IROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 14 o PROJECT NAME The Anderson Residence (Guest House) DATE 10/9/2003 SYSTEM NAME Guest Suite #2 FLOOR AREA 578 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM . SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest Suite #2 Guest Suite #2 1 458 11,364 2,106 458 11,364 2,106 373 14,096 PAGE TOTAL.- 1 -4581 11,3641 2,10611 .3731 14709�6] TOTAL 1 .4581 11, F 3731 14,0961 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 14 o ROOM HEATING PEAK LOADS Project Title ]Date The Anderson Residence (GiLiest House) 110/9/2003 Room Information Desiqn Conditions R6om Name 'Guest Suite #2 Time of Peak Jan 12 am Floor Area 578 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: Infiltration: x x x x /'60] x ch dule AirSensible Area CollingHeight ACH 01 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,096 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 15 of 16 578.0 x x x x x x x x x x x x x x x x x x x x x x X. x x x x x x x x x x x x X x X x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 745 942.0 0.0566 46.0 2,454 0.6000 46.0 1,380 24.0 0.3872 46.0 427 48.0 0.4000 46.0 883 perimeter 91.0 45.5 4,140 Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: Infiltration: x x x x /'60] x ch dule AirSensible Area CollingHeight ACH 01 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,096 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 15 of 16 0 RtSIDENTIAL ROOM -COOLING LOAD -SUMMARY The Anderson Residence (Guest House) 10/9/2003 Project Title Date Room Name Guest Suite #2 Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 0 F Design Temperature Diffdrence: 370F Conduction Area U -Value DETD Btulhr x 56.0 = 906 x Items shown with an asterisk denote conduction through an Interior surface to another room. 35.6 = 1,899 x 37.0 = 1,110 x 35.6 = 331 x Area 37.0 = 710 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk denote conduction through an Interior surface to another room. Shaded Unshided Solar Gain Orientation Area SGIF Area SGIF SC Btu/hr Vert.Sldr (1) (North) 0.0 x 15 + 10.0 x 1 )X 0.445 = 67 P 2) (North) 0.0 x 15 + 10.0 )( 1 )X 0.445 = 67 FrnchDr 0) (South) 0.0 x 15.+ 48.0 x 32)X 0.390 = 598 FxdGIsWdw (5) (West) 0.0 X 15 + 30.0 X 73)x 0.44 = 975 x + x -)x x + x )x x x )x x + x )x x + x )X x + x F--]) x Sched. Page Total 1,7071 Internal Gain Frac. Area Heat Gain Btu/hr Liqhts 1.00 578 0.500 Wafts/sqft x 3.41 BtuhfWaft 986 Occupants 1.00 X 578 X 255 Btuh/occ. 333 sqft/occ. 443 Receptacle 1.00 x 578 x 0.000 Wafts/sqft x 3.413 BtuhfWaft 0 Process 1.00 X, 578 x 0.000 Wafts/sqft x 3.413 BtuhfWaft 0 Infiltration: x x x x 60] 3 2Z� Air Sensible Area Ceiling Height ACH Fraction FOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,3641 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 225 Btuh/occ. sqft/occ. Receptacle 1.00 x x 0.000 Wafts/sqft x BtuhfWaft = Process 1.00 x x 0.000 Wafts/sqft x BtuhfWaft = Infiltration: .001 x ant x Area x Ceiling Height x ACH 60] InN Fraction FTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,1061 JEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 16