06-0463 (SFD)4 P.O. BOX 1504 VOICE -(760) 777-7012 .
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS(760) 777-7153
BUILDING PERMIT
Date: 5/18/06
Application Number: 06-00000463 Owner:
Property Address: 80678 VIA PESSARO . JIM MURDOCK
APN: 772-500-009- - - 38315 ABERDEEN DRIVE
Application description: DWELLING - SINGLE FAMILY DETACHED MURRIETA, CA 92562
Property Zoning: LOW DENSITY "RESIDENTIAL
Application valuation: 372504 MAY 19 2006
Contractor: t�
INIA
Applicant: Architect or Engineer: OLSON CONSTRUCTION. INT)
CITU OF E D PT.
38315 ABERDEEN DRIVE FINANCE DEPT.
MURRIETA, CA,°2562
(909).721-9871
Lic. No.: OOR SQUARE FOOT Lic. No.: 386853
.. LICENSED CONTRACTOR'S DECLARATION - - - WORKER'S COMPENSATION DECLARATION -
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with - Ihereby affirm under penalty of perjury one of the fallowing declarations: - -
,. Section 7000) of Division 3 of the Business an rofessionals Code, and my License is in full. force. and effect. _ I have.and will maintain a certificate of'consent to self-insure for workers' compensation, as provided
License Class' B , License No.: 386853 for by Section 3700 of the Labor Code, for. the performance of the work for which this permit is.
�y`issued.
Date: S IQ�V `-Contractor.._ i �� _ auI-have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor -
_ Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER-BUILDER DECLARATION .. insurance carrier and policy number are:
• I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the _ - Carrier STATE FUND Policy Number 07114084
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ _ I certify that; in'the-perrformance of the work for. which this permit is issued, I shall not employ'any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California,
.. permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I qb ome subject to the workers' compensation provisions of Section
License. Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or - - - 3700 o a or Code, I with comply with those provisions. - -.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Datesnt
Applica,
as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND -
and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - - one year of completion, the owner-builder will have the burden of proving that he or she did not build or - - -
improve for the purpose of sale:). - - APPLICANT ACKNOWLEDGEMENT -
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.: IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
7044, Business and Professions Code:. The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application.
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for .
pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application,
1 _ 1 I am exempt under Sec: B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
_ Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
.. CONSTRUCTION LENDING AGENCY permit to cancellation.
hereby affirm under penalty of perjury that there,is a construction lending agency for the performance of the I certify that 1" have read this application and state that the above information is correct. I agree to comply with-'all "
work for which this permit is issued (Sec. 3097, Civ. C.1. - city and county ordinances and state laws rela ' struction, and hereby authorize representatives
of this county to enter upon the above-mentioBed property ins ction purposes. -
Lender's Name:-
_ r" DateJ���-0�-Signature-(Applicant or Agent): ~
• Lender's Address:
LQPERMIT - .
Application Number .
. . 06-00000463
Permit ..
BUILDING PERMIT
Additional desc .. .
Permit Fee
1595.00
Plan Check Fee..
1036.75
Issue Date-
Valuation
372504
Expiration Date
11/14/06
Qty Unit Charge
Per.
Extension
BASE
FEE
639.50
P 273.00 3.5000
--------------------------------------------------------------------------
THOU BLDG
100,001-500,000
955.50
Permit ..
MECHANICAL
Additional desc .
Permit Fee
114.50
Plan Check Fee :..6
28.63 .
Issue Date . .
Valuation . .
0
Expiration Date...
11/14/06
y
Qty Unit Charge
Per
Extension.
BASE
FEE
15.00.
3.00. 9.0000
EA MECH
FURNACE <=100K
27.00.
3.00 9.0000
EA MECH
B/C .<=3HP/100K BTU
27.00 '
6.00 6.5000
EA MECH
VENT FAN
39..00,
1.00 6.5000
EA MECH
EXHAUST HOOD
6:50, .
Permit :
ELEC-NEW-RESIDENTIAL
Additional desc .. .
Permit Fee
197.01
Plan Check Fee
49.25. .•
Issue .Date
•Valuation . . ._
0.,
Expiration.Date
Qty.. Unit Charge
Per
Extension
-BASE
FEE
15.00 ,.
4334.00 -:0350
ELEC
NEW RES - 1 OR 2 FAMILY
151.69.
766.00` 0200
ELEC
GARAGE OR NON-RESIDENTIAL
15.32
1.00_ 15.0000
EA ELEC
TEMPORARY POWER POLE
15:00
Permit.
PLUMBING
Additional desc'.
Permit Fee. .
212.25•
Plan Check Fee
``53.06
Issue Date . . . .
Valuation'
0
Expiration Date
11/14/06
Qty Unit Charge
Per
Extension .
BASE
FEE
15..00
22.00 6.0000
EA PLB.FIXTURE
132.00
LQPERMIT -
'
Application,Number 06-00000463
Permit. PLUMBING
Qty Unit Charge. Per
Extension
1.00 15.0000 EA PLB BUILDING SEWER
15.00
2.00 7..5000 EA PLB WATER HEATER/VENT
15.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3:00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
11.00 .7500 EA PLB GAS PIPE >=5
8.25
1.00 15.0000•EA PLB GAS METER
15.00
Permit . . GRADING PERMIT
Additional desc .
Permit Fee 15:00 Plan Check'Fee
.00
Issue -Date. Valuation
0.' /
Expiration Date 11/14/06
Qty ' Unit Charge Per.
Extension
BASE FEE
15:00 .
Special Notes and Comments
_
4334 .SQ FT. SFD PERMIT DOES NOT INCLUDE
BLOCK WALLS, POOL/SPA: May 18;x.2006: ,
3:04:05 PM SRUBIO .
Other Fees ART IN PUBLIC PLACES -RES
431.26'".
DIF -COMMUNITY CENTERS -RES.
74:00
DIF CIVIC.CENTER - RES
480•.00
. ENERGY REVIEW FEE
103.68
DIF FIRE PROTECTION -RES',
140.00 •'
GRADING PLAN CHECK FEE
00
DIF': LIBRARIES. = RES
355.00' .
DIF PARK�MAINT FAC -"RES
22.00
_... DIF PARKS/REC = RES
892:00
STRONG MOTION -(SMI) - RES
37.25
DIF STREET MAINT,FAC-RES
67.00 "
DIF TRANSPORTATION - RES
1666".00
Fee summary ChargedPaid Credited
Due
Permit Fee Total:" 2133.76 .00 00
2133.76.
Plan Check Total 1167.69 500.00 .00
667.69
Other' Total 4268.19 00." .00
4268.19 a
Grand Total 7569.64 500.00 .00
7069.64:
.. LQPERMIT. .. -
..
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.1 by EnergySoft Job Number. .- ` - User Number. 4496
L L
TABLE OF CONTENTS
Cover'Page
N _ �
Table of Contents -:
2
Form CF -1R Certificate of Compliance:, -
3
Form MF -1 R Mandatory Measures Summary
7
Form WS -5R Residential Kitchen- Lighting r`
9
HVAC System Heating and Cooling Loads'Summary,
10
EnergyPro 4.1 by EnergySoft " ; Job Number.
User Number. 4496
Certificate Of Compliance:
Residential
ft2
(Part 1 of 4) CF -1 R
Murd.0C ReSirlence
ft2
Raised Floor Area:
0
04/2912006
Project Title
4,334
ft2
Average Ceiling Height:
Date
80678 Ma Pessaro I a
Project Address
Dionta
1.00
Building Permit #
Thealc Mgn
(951) 679-3850
Documentation Author
Telephone
Plan Check/Date
�nero
15
Field Check/Date
CompliNdco Method
Climate Zone
TDV EnergyUse
Standard
Proposed Compliance
(kBtu/sf-yr
Design
Design
Margin
Space Heating
1.22
1.62
-0.40
Space Cooling
48.00
43.10
4.91
Fans
7.21
8.02
-0.81
Domestic Hot Water
5.92
6.93
-1.01
Pumps
0.00
0.00
0.00
Totals
62.35
59.67
2.68
Percent better than Standard:
4.3%
Building Type: Y Single Family ❑ Addition
❑ Multi Family ❑ Existing + Add/Alt
Building Front Orientation: (S)180 deg
Fuel Type: Natural Gas
Fenestration:
Area: 590 ft 2 Avg. U: 0.28
Ratio: 13.6% Avg. SHGC: 0.27
BUILDING ZONE INFORMATION
Zone Name Floor Area Volume
Total Conditioned Floor Area:
4,334
ft2
Existing Floor Area:
n/a
ft2
Raised Floor Area:
0
ft2
Slab on Grade Area:
4,334
ft2
Average Ceiling Height:
10.0
ft
Number of Dwelling Units:
1.00
Number of Stories:
1
# of
Units Zone Type
Res HVAC 4,334 43 3dn X00_ Conditioned
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Roof Wood 4 334 n 039 R-30 R--0 p_ p2
Wall Wood 760 0.074 R_19 R-0.0 180 go
Wall -Wood_ 717 0 074 R_19 —R-0, n 970 g0
Wall__ -Wood_ 424 _0_OZ4 R-19 R-0 0 0911
Wall -Wood— 749 0.074 R_19 R-0.0 gD- gn
Gains Condition
Y / N Status JA IV Reference
Thermostat Vent
Type Hgt. Area
Setback 2 —nla
Location / Comments
01-A7 Whole House 7nna
09-A5 Whog o ase Zone
_09-A5 Whole House Zone
09-A5 Whole House lone
09-A5 Whole Homse Zone
EnergyPro 4.1 by EnergySoft User Number. 4496 Job Number. Paae:3 of 10 1
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Murdock Residence 04/29/2006
Project Title Date
FENESTRATION SURFACES
True
Cond.
Location/
# Type
Area LI -Factor' SHGC2
Azm. Tilt
Stat. Glazing Type
Comments
A- -1(i!Sl
_5.0-0 -0 280 _NFRC -0.27 NERC 18n --qQ New-D_oub
r Low E
_ Whole HouseZoIIe
2 Window Left (W)
93.0 0.280 NFRC 0.27 NFRC
270 90 New
Double Non Metal Clear Low E
Whole House Zone
3 Window Rear (N)
130.0 0.280 NFRC 0.27 NFRC
0 90 New
Double Non Metal Clear Low E
Whole House Zone
4 Window Rear (N)
256.0 0.280 NFRC 0.27 NFRC
0 90 New
Double Non Metal Clear Low E
Whole House Zone
5 Window Right (E)
61.0 0.280 NFRC 0_27 NFRC
90 90 New
Double Non Metal Clear Low E
Whole House Zone
Run Inflation Time: 0412910611:53:02 Run Code: 1146336782
EnergyPro 4.1 by EnergySoft User Number: 4496 Job Number. Page:4 of 10
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613.
INTERIOR AND EXTERIOR SHADING Window Overhang
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt.
REA.
Left Fin Right Fin
Dist. Len. Hgt. Dist. Len. Hgt.
1 Bug Screen 0.76 5.0 4.0
2 Bug Screen 0.76 5.0 4.0
3 Bug Screen 0.76 5.0 4.0
4 Bug Screen 0.76 5.0 4.0
5 Bug Screen 0.76 5.0 4.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside
Type (sf) (in.) Cap. Cond. R -Val.
2.0 0.1 2.0 2.0
2.0 0.1 2.0 2.0
2.0 0.1 2.0 2.0
8.0 0.1 8.0 8.0
2.0 0.1 2.0 2.0
JA IV Reference
Condition Location/
Status Comments
PERIMETER LOSSES Insulation
Type Length R -Val. Location
JA IV Reference
Condition Location/
Status Comments
Slab Perimeter 288 None No Insulation
26 -Al
New Whole House Zone
Run Inflation Time: 0412910611:53:02 Run Code: 1146336782
EnergyPro 4.1 by EnergySoft User Number: 4496 Job Number. Page:4 of 10
Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R
Murdock Residence 04/29/2006
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
Res HVAC Central Furnace 93% AFUE Split Air Conditioner 14.0 SEER New Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
Res HVAC Ducted Ducted Attic 6.0 New No
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS , Ratedl
Tank
Energy
Standbyl Tank Insul.
Water Heater. # in Input
Cap.
Condition Factor
Loss R -Value
System Name Type Distribution ' Syst. (Btu/hr)
(gal)
Status or RE 1
(%) Ext.
RHEEM 44V50 or = Small Gas No Pipe Insulation 2 40,000
50
New .0.63
n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: Gary M. Garcia Planning -Design -Consulting ;
Address: 311 West Alvarado St.
Fallbrook, Ca 92028 ..
Telephone: -7')Q V2QA
Lic. #:
S-1 at —b 4
(signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Documentation Author
Name: James Fov
Title/Finn: The Calc Man
Address: 31160 Willowood Way
Menifee, CA 92584
Telephone: (951) 679-3850
(signature) (date)
Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R
Murdock Residence 04/29/2006
Project Title Date
` Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
aaencv determines the adeauacv of the justification. and may reiect a buildina or design that otherwise comolies based on the
A
HERS Required Verification`
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
__.
installation certificate. Pian Field
The Cooling System "Bryant556AN036/350MAV036060 or-" includes credit for a 12.1 EER Condenser. A certified HERS rater must
field verify the installation of the correct Condenser.
s
Mandatory Measures .Summary: Residential ` (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE -
applicable. N/A DESIGNER MENT
Building Envelope Measures
§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
Q
❑
§ 150(b): Loose fill insulation manufacturers labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not Y
❑
❑X
❑
apply to exterior mass walls). Y
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.. '
❑
1XI
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
r>
1. Masonry and factory -built fireplaces have: .,
a. losable metal or glass door covering the entire opening of the firebox 4
❑
Q
❑
b. outside air intake with damper and control, flue damper and control
❑
❑X
❑
2. No continuous burning gas pilot lights allowed.
❑
❑X
❑
§ 150(0: Air retarding wrap installed to comply witt§ 151 meets requirements specified in the ACM Residential Manual
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. •
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
' ❑
❑
permeance rate no greater than 2.0 pemtiinch.
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and
❑
El
CF -6R Form:
116-17:
§ 116-17: Fenestration Products, Exterior Doors, and InfiltratioNExfiltrabon Controls. -•,
' .
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑X
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
❑ '
Q
❑
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accorda11 nce with ASHRAE, SMACNA or ACCA.
❑
❑X
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
Q
El
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.`
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be extemallywrapped with
❑
❑X
❑ ,
insulation having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑X
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 1504B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non{ecirculating systems, and entire
❑
❑X
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source -
❑
❑
❑
and indirect hot water tank shall be insulated to Table 150-6 and Equation 150-A. -
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A:
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment
❑
❑
❑
maintenance, and wind.
6. Insulation for chilled water piping and refrigerant suction piping incudes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
.
7. Solar water -heating systemstcollectors are certified by the Solar Rating and Certification Corporation.
❑
❑ :
❑
EnergyPro4.1 by EnergySoft User Number. 4496 •Job Number.
Page:7 of 10
- y
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE -
applicable. NIA DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑
❑X
sealed sheet metal, dud board or flexible dud shall not be used for conveying conditioned air. Building cavities and
❑
❑
support platforms may contain duds. Duds installed in cavities and support platforms shall not be compressed to cause
❑
❑
reductions in the cross-sectional area of the duds.
❑
❑
S. Joints and seams of dud systems and their components shall not be sealed with cloth back rubber adhesive
❑
❑
dud tapes unless such tape is used in combination with mastic and draw bands.
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
4. Exhaust fan systems have back draft or automatic dampers.
❑
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shalt be high efficacy luminaires.
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑
❑
dampers.
❑ ❑X ❑
controlled by an occupant sensor that complies with Section 1219(d) that does not tum on automatically or have an
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑
❑ X❑ ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
retardant and provides shielding from solar radiation that can cause degradation of the material.
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article
7. Flexible duds cannot have porous inner cores.
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
i
2. System is installed with:
a. At least 36" of pipe between fitter and heater for future solar heating:
b. Cover for outdoor pools or outdoor spas:'
3. Pool system has directional inlets and a circulation pump time switch.
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
burning pilot light. (Exception: Nonelectrical cooking appliances with pilot < 150 Btu/hr)
11
El
§ 118 (i): Cool Roof material meets specified criteria :.
❑ ❑ ❑
Lighting Measures
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
®
❑
§ 118 (i): Cool Roof material meets specified criteria :.
❑ ❑ ❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-0, and do not contain a medium screw base socket (E241E26). Ballasts for lamps 13 Wafts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 15D -C,
❑ Q ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ X❑ ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shalt be high efficacy luminaires.
❑ a ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ ❑X ❑
controlled by an occupant sensor that complies with Section 1219(d) that does not tum on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ X❑ ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ X❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low{ise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro4.1 by EnergySoft User Number. 4496 Job Number.
Page:B of 10
'Residential Kitchen
Lighting Worksheet -
WS -5R
Murdock Residence
04/29/2006
Project Title r
R Date
At least 50% of the total rated wattage of
permanently installed luminaires in kitchens must be in luminaires.that are high efficacy luminaires
• as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide
the following, information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type
High Efficacy? Watts Quantity. Wafts
Other Watts
(1) 4 ft Fluorescent T8 Rapid Start
Yes X1 No n 22.0x, 4 =
88 or
(1) 32w Compact Fluorescent Triple 4 Pin
Yes X No 32.0 , x' ' 13 _
416 or
Chandelier Candle type Light bulbs
Yes No X 15.0, X 9
or
135 '
Yes No . { x =
or
'
.:Yes No X" "
or
Yes No X' _
or
Yes No -x =
or
Yes No X =
or
Yes : No _ x
or
Yes No x _
or
Yes No
or
Yes No x _
- .
or
Yes _ No x =
or
-
Yes No ` x =
or
Yes No c .. .X =
or
_ ..
Yes No X., =
_
Yes :
or
No j x,
or
•- =
Yes No x1-
+
or
Yes No_
x -
or
Yes No' x =
or
*
" Total' A:
B
135
COMPLIES IF A,—> B
YES ® NO ❑
Al
EnergyPro 4.1 by EnergySoft :-
User Number. 4496 Job Number.
Page:9 of 10
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Murdock Residence 04/29/2006
SYSTEM NAME FLOOR AREA
Res HVAC 4,334
Number of Systems
3
Heating System
Output per System
56,000
Total Output (Btuh)
168,000
Output (Btuh/sgft)
38.8
Cooling System
Output per System
36,000
Total Output (Btuh)
108,000
Total Output (Tons)
9.0
Total Output (Btuh/sgft)
24.9
Total Output (sgftfron)
481.6
Air System
CFM per System
1,200
Airflow (cfm)
3,600
Airflow (cfm/sgft)
0.83
Airflow (cfmfron)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
I Sensiblel
Latent
I I CFM
I Sensible
1,904
40,515
-604
1,296
48,276
0
6,653
5,640
0
0
0
0
0
0
0
0
0
6,653
5,640
53,821 -6 59,557
Bryant556AN036/350MAV036060 or- 79,501 12,682 168,000
Total Adjusted System Output 79 501 12,682 168,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am
EATING 5Y5TEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 68.5 of 68.5 of 105.0 of
O I Supply Air Ducts
Outside Air
0 cfm
Supply Fan Heating Coil 103.5 of
3600 cfm ROOMS
68.5 of 70.0 of
h Return Air Ducts 4
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
110.0/72.5OF 76.7/61.8OF 76.7/61.9OF 55.0/53.8oF
OSupply Air Ducts
Outside Air Is
0 cfm
Supply Fan Cooling Coil 56.7 / 54.5 of
3600 cfm 45.6% R.H. ROOMS
76.7/61.8 of 75.0/61.2OF
Return Air Ducts 4 I
EnergyPro 4.1 by EnergySoft User Number. 4496 Job Number. Paae:10 of 10 1