Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-3277 (SFD)
'. • Z P.O. BOX 1504 78-495. CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 05-00003277 80753 VIA PESSARO 772-500-068- - DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 374714 Owner: NRI CCP"I 81100 AVE 53 LA QUINTA, CA 92253 ti VOICE (760) 777-7012 FAX (760) 777-7011 1 INSPECTIONS (760) 777-7153 25/06 Contractor: Applicant: Ar hitect or Engine MONARCH HOMES DESERT DIV, INC- '4 73290 EL PASEO, SUITE 44 • ? . (760)D568E3905CA - Q'726 0 J r LiC_ No. -.457228 ---- ---------- LICENSED CONTRACTOR'S DECLARATION - - WORKER'S COMPENSATION DECLARATION I.hereby affirm under penalty of per' that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the siness and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided .License Class: B License No.: 45-7228 for. by Section.3700 of the Labor Code, for the performance of the work for which this permit is `/(/ issued. ,\ D� L'J�pntracto - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the "performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND I Policy Number 0028122-2005 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to. - 1 certify that, in the pert ance of the work for which this permit is issued, I shall not employ any ' construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the, person in any mann r -so as to become subject to the workers" compensation laws of California, permit to file a signed statement that he or. she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I hould b me bject to the workers' -compensation provisions of Section k.5 License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or r - 3700 of the Labor o , sh fo co pl ith thoseyrovisions. " that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by c' - any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500): o(I App lica (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and. the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, - SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the - DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE_LABOR•CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). • APPLICANT ACKNOWLEDGEMENT - (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. _ property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed - 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. . Date: Owner: 2. Ahy permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that th above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to bu' ding u hereby authorize representatives of�ZjWature on the above-mentioned grope y r insp ion pur Lender's Name: (Applicant or Agentl• Lender's Address: • - LQPERMIT ' t Application Number . ... 05-00003277 Permit. ` . . . BUILDING -PERMIT Additional desc . Permit Fee . . ; 1602.00 Plan Check Fee 1041.30 - Issue Date . . . . Valuation 374714 Expiration Date 10/22/06 Qty Unit Charge Per Extension BASE FEE 639.50 275.00 3.5000,THOU BLDG 100,001-500,000 962.50, - Permit •. ELEC-NEW RESIDENTIAL Additional desc ... Permit Fee . . 191-.90 Plan Check Fee,. 47.98 Issue Date Valuation . • . 0 Expiration Date: 10/22/06 " Qty Unit Charge Per Extension BASE FEE 15.00 4377.00 .0350_ ELEC NEW RES - 1 OR -2 FAMILY, 153.20 1155.00 .0200, ELEC GARAGE OR NON-RESIDENTIAL 23.70 Permit GRADING PERMIT Additional desc . Permit Fee 15:00 Plan Check Fee .: 00 Issue Date . . Valuation . . . 0`- Expiration Date 10/22/06 Qty Unit Charge Per Extension' BASE FEE. '.. 15.00 Permit -MECHANICAL Additional desc . Permit Fee . . . . 132.50 Plan Check Fee 33.13. Issue Date Valuation 0 Expiration Date'. 10/22/06 Qty' Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000'EA MECH B/C <=3HP[100K.BTU 36.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . . . PLUMBING' g LQPERMTT Application Number 05700003277 Permit . . PLUMBING Additional desc . Permit Fee 201.00 Plan Check Fee 46.50 Issue Date . . . . Valuation . . 0 Expiration Date 10/22/06 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 6.0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT' 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 x1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 12.00 .7500 EA PLB GAS PIPE >=5 9.00 1.00 15.0000 EA PLB GAS METER 15.00 ---- ---- ---------------------------- Special Notes.and Comments SFD - 4377 SQ.FT. LIVING, R-3 OCCUPANCY, TYPE V -N CONSTRUCTION, 2001'' CODES. **PERMIT DOES NOT INCLUDE BLOCK WALLS, POOLS,SPA, "AND WATER.FEATURE.**. - - - - - -- --------------------------------- other Fees . . . . . . : . ART IN PUBLIC PLACES -RES' ---- ------ -- 436:78 DIF COMMUNITY CENTERS -RES 74.00.; DIF CIVIC CENTER - RES 480.00.° ENERGY REVIEW FEE 104.13 DIF FIRE PROTECTION -RES - 140.00, .DIF LIBRARIES - RES 355.00 - DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES, 892.00 STRONG'MOTION (SMI) - RES` .37.47 -DIF STREET MAINT FAC -RES 67.00 . DIF TRANSPORTATION - RES 1666.00 _. Fee summary _ :Charged Paid Credited Due •. ---------------_--------- ---------- ---------- Permit Fee Total 2142.40` .00 .00 2142.40 Plan Check Total 1168.91 500.00 .00 668.91' Other Fee Total' 4274'.38 .00 :00 4274.38 ' Grand Total 758569 500.00 .00 7085.69 - LQPERMIT .. - r; ► " ey. P.O. BOX 1504 APPLICATION ONLY Building®,?" ��1 �'9 78-495 CALLE TAMPICO Address O -3 Y'� .�1��wv LA OUINTA, CALIFORNIA 92253 Owner DAz.,1.10) �,L�.S �� S BUILDING: TYPE CONST. OCC. GRP. Mailing r1'7 ?1-1 Address � � � �.5�� A.P. Number C' !%���%JZip ���� Tel. Legal Description 4©%63�r� 2/ a f�'Z Cont��or i / Project Description�,'��� 6 4-1—g -,A cy Addres� s a �� &--7— n� Ci Zip j� Tel. T State Lic. City & Classif. A-7 72,0 Lic. # Arch., Engr., Designer Address � Tel. X ilo ,V` SrA �u .!,tyi A_ J g2Zs 5 I Lic. # LICENSEDCONTRACTOR'S DECLARATION affirm that I am licensed under provisions of Chapter 9 (commencing with Se( )'vision 3 of the Business and Professions Code, and my license is in full force OWNER -BUILDER DECLARATION I he by affirm that I am exempt from the Contractor's License Law for the to owing reason: ( c. 7031.5, Business and Professions Code: Any city or county which re uires a permit to co struct, alter, improve, demolish, or repair any structure, prior to its issu ce also requires the plicant /or such permit to file a signed statement that he is licensed rsuant to the provisions l the Contractor's License Law, Chapter 9 (commencing with Secti n 7000) of Division 3 0/ the usiness and Professions Code, or that he is exempt therefrom, a d the basis for the alleged a mption. Any violation of Section 7031.5 by any applicant for a p it subjects the applicant to a iwl penalty of more than five hundred dollars ($500). ❑ I, as owner of thV rty, or my employees with wages as their sole comp sation, will do the work, and the ste is not intended or offered for sale. (Sec. 7044, Busi ess and Profes- sions Code:The Cotor's License Law does not apply to an owner o/ pr party who builds or improves thereonwho does such work himself or through his awn a loyees, provided that such improvemare not intended or offered for sale. If, however, a building or im- provement is sold one year of completion, the owner -builder will ave the burden of proving that he did ' d or improve /or the purpose of sale). ❑ I, as owner of the , am exclusively contracting with licensed ntractors to construct the project. (Sec. 7u Ness and Professions Code: The Contra or's License Law does not apply to an ownro rty who builds or improves thereona who contracts for such projects with a cont(s) I ensed pursuant to the Contractor's ense Law)❑ I am exempt und. B. & P.C. for this reason WORKER'S OMPENSATION DEC(IARATION I hereby affirm that I have a certifi ate of consent to s f insure, or a certificate of Worker's Compensation Insurance, or a certifie opy thereof. (Se . 3800, Labor Code.) Policy No. Company 0 Copy is filed with the city. ❑ Cart i 'ed copy is ereby furnished. CERTIFICATE O� EXE TION FROM WORKERS' COMPEIJSA ON INSURANCE (This section need not be completed it the pe is for one hundred dollars ($100) valuation or less). I certify that in the performance of the w r for which this permit is issued, I shall not employ any person in any manner so as to be ome ubject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after makin this Certilic to of Exemption you should become subject to the Workers' Compensatio provisions of he Labor Code, you must forthwith comply with such provisions or this pe it shall be dee d revoked. CONS UCTION LENDING AG NCY I hereby affirm that there is construction lending age_ geor the performance of the work for which this permit is issued. ec. 3097, Civil Code.) Lender's Name Lender's Address This is a building per it when properly filled out, signed and v 'dated, and is subject to expiration if work the er is suspended for 180 days. I certify that I hav read this application and state that the above to is correct. I agree to comply w' all city and county ordinances and state laws elating to building construction, and h eby authorize representatives of this city to enter the bove-mentioned property for ins ion purposes. Signature of ap icant Dale Mailing Ad s City, State ip WHITE = BUILDING DEPARTMENT Sq. Ft. Size New No. No. Dw. Add ❑ Alter ❑ Repair ❑ Demolition ❑ cc? aJTl-r- 7-f Zee it [ L I e,git_ 7enoo - i5 -7I - V-07 9 Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing M TOTAL REMARKS DEPT. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School. District This Bax For District use only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760) 398-5909 — Fax (760) 398-1224 AREA: - - ' AMOUNT . LEVEL ONE AMOUNT: 'LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE' RFCFIPT- CHFCK N' INITIALS CERTIFICATE OF COMPLIANCE , (California Education Code 17620) Project Name:Resdt,engetitrth' a deaway i Date: April 25, 2006 Owner's Name: David & Jan Jacobsen Phone No. Project Address: 80-753 Via Pessaro ' Project Description: APN: 772-550-068 Tract #: Lot #'s:' 343 Type of Development: Residential %X Commercial Industrial Total Square Feet of Building Area: 4,248 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: ` April 25, 2006 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code - Project `.` Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 4,248 Amount per Sq.Ft. $2.63 Amount Collected $11,172.24 Building Permit Application Completed: Yes/No _ By: Carey M. Carlson, Asst. Supt., Business Services. Certificate issued by: Elvira Mattson, Office Technician Signature: ' NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997,"requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees" ), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the valid ity'thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code_. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of - Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. L':':c;t»suocside� 1eescertiiicaaL u('cainpli u�ie [,rm tabl�l'(3 IISI>.doc. 1/16/03 T -'DOC p 2005 0355487 `. 05/05/2005 08;00A Fee:13.00 RECORDING R�STED BY: - Page 1 of 3 Doc T Tax Paid . ' Recorded in Official Records Fidelity National Title Company _} County of Riverside Escrow No. 7117-MB4 Larry W: Ward Title Order No. /].1r�/yTr �JJ� �. Assessor; -County Clerk & Recorder and Tax Statement T Recorded o When Document',I IIIIII IIIIIII fIII IIII�� 1 1 II IIIIIII IIIII'III VIII IIII II II Jacobsen Development Group, LLC 73-290 EI Paseo, Ste. #4 Palm Desert, CA 92260 77ot'SDD-6> RANT DEED - - -- The undersigned grantor(s) declare(s) 7S3 vt J Documentary transfer tax is $825.00 !mea 0 ( X ..] computed on full value of property conveyed, or [ ] .computed on full value less value of liens orencumbrances remaining at time of sale, [ X ] City of La•Quinta , FOR A VALUABLE CONSIDERATION, receipt ofwhich is,hereby acknowledged, David K. Ward and Karen L. Ward, Husband and Wife as joint tenants k" 4 hereby GRANTS) .to Jacobsen Development Group,.LLC, a California. Limited Liability Company the following described real property in the City of La Quinta County of Riverside, State of California: SEE EXHIBIT ONE ATTACHED HERETO AND MADE A PART HEREOF � Gl-- 3 TZ-L�, ?�Fp` "0 - L°f 393 DATED: February 15, 2005r'" = STATE OF CALIFORNIAO COUNT OF ON before me, David K. War ' Gc perponally appeared Karen L. War p me (or proved .to me on the basis' of sati cto evidence) to be the 'persor-s whose ., name( s=uescribed to the within instrument and acknowledged to.D3q that he/she/ty cuted the same in his/hwh e e• uthorized capacity es and that L. L. HERNANDI by his/her/h ignatureo on the instrument the Cornmissbn 1514214 person or the entity upon behalf of which the i • �roN Public - Calltomla person(&ted, executed the instrument. RNersideCounry - MY Comm. Expires Sep 18, 2008 Witness my han ci al, Signature 9 2005 A L TAX STATEMENTS AS -DIRECTED ABOVE FD -213 (Rev'7 GRANT DEED �' ®N®�fG,®�!J®�1 ®N®11��i � 77ot'SDD-6> RANT DEED - - -- The undersigned grantor(s) declare(s) 7S3 vt J Documentary transfer tax is $825.00 !mea 0 ( X ..] computed on full value of property conveyed, or [ ] .computed on full value less value of liens orencumbrances remaining at time of sale, [ X ] City of La•Quinta , FOR A VALUABLE CONSIDERATION, receipt ofwhich is,hereby acknowledged, David K. Ward and Karen L. Ward, Husband and Wife as joint tenants k" 4 hereby GRANTS) .to Jacobsen Development Group,.LLC, a California. Limited Liability Company the following described real property in the City of La Quinta County of Riverside, State of California: SEE EXHIBIT ONE ATTACHED HERETO AND MADE A PART HEREOF � Gl-- 3 TZ-L�, ?�Fp` "0 - L°f 393 DATED: February 15, 2005r'" = STATE OF CALIFORNIAO COUNT OF ON before me, David K. War ' Gc perponally appeared Karen L. War p me (or proved .to me on the basis' of sati cto evidence) to be the 'persor-s whose ., name( s=uescribed to the within instrument and acknowledged to.D3q that he/she/ty cuted the same in his/hwh e e• uthorized capacity es and that L. L. HERNANDI by his/her/h ignatureo on the instrument the Cornmissbn 1514214 person or the entity upon behalf of which the i • �roN Public - Calltomla person(&ted, executed the instrument. RNersideCounry - MY Comm. Expires Sep 18, 2008 Witness my han ci al, Signature 9 2005 A L TAX STATEMENTS AS -DIRECTED ABOVE FD -213 (Rev'7 GRANT DEED �' P.O. Box 1504 •� LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENT 94� 78-495 CALLE TAMPICOf (760) 777-7012 OFTk� 'LA QUINTA,'CALIFORNIA 92253 " .wA FAX (760) 777-7011 April 25, 2006 Mr. LeRoy Meiner { Monarch Homes 73-290 EI Paseo, Suite #4 Palm Desert, CA 92260 - r Es5ARa RE: Plan Review Extension Request - 80-753 Via Seye4a Dear Mr. Meiner: j I have reviewed your letter dated 4/25/06,requesting a time extension for the Plan Review of the single family dwelling proposed to be built at the above address under Application #05-3277. f : Plan review status: Original application`date: 7/29/05 180 -day expiration date: 1/25/06 180 -day extension dater 7/24/06 Under the provisions of California-Building.Code Section ;107.4; your request is hereby granted. Because the Building Code specifies'that "no application .shall be extended more • than once," please be advised that unless-a'building:permit for this project is r issued on or before Monday, July.24, 2006, your application will expire - automatically. You truly, Greg Butler k; Building & Safety Manager JACORSF T rVGinPxICNT� � C� UP LLC iy City of La Quinta April 25, 2006 Building & Safety Department 78-495 Calle Tampico' La Quinta, CA 92253 Re: 80-753 Via Savona, Hideaway Gentlemen: Please consider this letter as our request to the City of La Quinta, Building Department, for an extension of time on our plan check review.. The project address is 80-753 Via Savona, Hideaway. We originally submitted on July'29, 2005, and have had an inordinate amount of delays in getting our structural corrections completed in a timely manner. We realize we have gone beyond the normal plan check time line and, as a result, would be willing to adhere to a penalty fee. We feel this would be to'both our advantage due to the amount of man hours expended by the City and ourselves. Thank you for.your cooperation in this matter. Sincerely, LeRoy A. Me7r, Project Mana 73-290 El Paseo; Suite #4.. Palm'Desert, CA 92260. (760)568-3905 fax: (760)568-3946 www.monarchhomesonline.com . CSL "#809688 QPM -it ?? z - Sao - o to S CITY OF LA QUINTA - PUBLIC WORKS/ENGINEERING DEPARTMENT GREEN SHEET (PUBLIC WORKS CLEARANCE) FOR BUILDING PERMITS Form updated & effective 8/25/2005 Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works/Engineering Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to Applicant. Green Sheet approvals will be forwarded to the Building Department directly.by Public Works. Date: Z. • 2.8 - o Co Developer: , I2e_/ 4�_r �zc . Dwrow7 Tract No.: 2_9_"9t – Z- Tract Ms-'sAM0 e: 3z.7/7S Lot No.(s): 3 Address(s): gQ•?S3 ✓id- L.c. The following are the requirements for Public Works C ear e o authorize issuance of a building permit from the Building/Safety Department. CUSTOM HOMES: PROVIDE ITEMS W,'#3, #4 AND #5 BELOW TRACT HOMES: PROVIDE ITEMS #1, #2,13,44 (AS APPLICABLE) AND #6 BELOW COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2, #3 AND #5 BELOW, 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet . submittal until. a Pad Elevation Certificate .can be provided. 3. Attach recorded final map showing proposed building locations are legal lots. r5t.oc, OcPT 4: Attach a completed <1 acre per lot or infill project Fugitive"Dust Control project information form, PM10 plan &agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy. plan. PM10 plans for commercial and residential developments (beyond 1 lot) are submitted separately with grading plans and are subject to additional requirements. 5—Attach an approved precise grading plan for the building location(s). AO flood zone developments will require an approved flood plain development plan.�i.l 6. Attach an approved rough grading plan for the- building location(s). I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently completefor construction of the proposed. buildings)/structure(s) on the subject lot(s). Pursuant to findings, the above project may be released for building permit issuance. Recommerided by: Dated: > -5 l c, Declined for approval for reason(s) as follow(s), please correct and resubmit: TAPWDEPT\STAFFrGoble\Gmn Shm PW Release\050824GREEN SHEET COVERdoc J. City of La Ouinta PM, 10 Project Information (<1 acre per Lot or Infill Proiect)* Page 1 of 3 Yea Form updated & effective 8/25/2005 9 Project.Information Project Contractor: 'Proje'ct Phase Dr ✓s i01.1 y Project Phase (Check One): Project Name: Ind. Project Tract. '.-Number: Z. --'r c) Construction ❑ Demolition Lot Number(s): 3�3 _ Anticipated Start Date: •.c) Project Street Address: � go • ?5 ✓[c SstZ.o Q Anticipated Completion: l Z • 31 Total acres in active construction•(<1 acre per Lot) t»0 T "' S 1•-1 cc C ' ►W L7_12E s (D Project Contact Please Note: Dust control is required 24 hours a day, 7 days a week, Information regardless of construction status. Person listed below is responsible for Aust control during business and non- business hours. Name:. G.. Ee< Title: QqjEcT ti( -,jA Company Name: t ..l c - Mailing Address: -2 3 •290 t=i. Ao. City: /0d- g! State: Zip Code: z?. C� o Primary , Telephone 7 C'. '- SZ.9 • 3 5 0 'Number: Fax: %tc o Sig 3� S�Co 24 Hour Access/Emergency 7 (o • S ? 9 1,407 9 Phone: Cell Phone: ? S-7 8 `/-079 PM 10 Certificate Number:. r i o Z <S , I * Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. o ' T:\PWDEPT\STAFF\Goble\Green Sheet PW Release\050824MIN1 PM 10 PACKET GREEN SHEET.doc - - 0 City of La Quinta Site Specific Construction Phase PM 10 Agreement Page 3 of 3 Agreement updated & effective 8/25/2005 The siQnature'of the property owner (or authorized representative),' Shall act as ,his/her acknowledgement of dust control requirements and their enforceability, pursuant to AQMD Rules -403 and 403.1; o Shall constitute and agreement to comply with .all project' conditions 'as identified in the approved dust control plan; The property_owner (or authorized representative): o o r• Acknowledges that dust control is .required 24, hours a' day,'7 days a week, throughout the period of project performance, regardless of project size or status; • .Shall ensure that each and every contractor/subcontractor and' all. other persons associated with the project shall. be in continuous compliance with all requirements, of the�approved dust control plan; r • Shall take all necessary precautions to"mmimize dust, even,if additional measures beyond . ` those listed in the dust control plan are necessary;' • Shall authorize representative of the City/County. to enter upon the above mentioned property for inspection. and/or abatement purposes; and • Shall hold harmless the City/County 'and its' representatives from liability for any actions' related to this dust control plan or any.City/County initiated abatement activities. ' ` Signature of Property Owner or. -Authorized Representative Printed Name ; Title Date Company ; (etho's . THE WOODARD GROUP 05/23/2006 07:09 7607757739 WOODARDGROUP PAGE 02 Page 1 of 1. Date: 5/22/Z006 9-_54:44 P.M. Pacific Standard Time From: bmarshall @dT2,InteMet.co.m. aol com TO embnarchhomes.net, davidpjacobsen_@a41�m, Wood rd rPS-- May 22, 2006 W. Stewart Woodard 80880 Vista Bonita La Quinta, CA, 92253 RE: Jacobsen. O/Revised Roof Plan (518/06) & Elevations (5/9/06) Lot 343 at 80753 Via Pessaro Dear Mr. Woodard: r The Hideaway Design Review Committee met to discuss the proposed changes sent via facsimile for Lot 343. Please review the comments listed below. isroved-as 1. The revised roof plan submitted, removing a portion of overhang ra pp submitted assuming it does riot have an affect on the amassing Calculations (we did not compare to the full plah set during out meeting so we offer this as a side note - there may be .no relataox�.slup between the massing and the proposed change). pp y proposing tnination of shutters at one 2. It also appeared that.you werethe ell window. Tlu-mss cliainge is approved as su�btted As there was not much infbrruation provided' with the facsimiles .we received, please contact the committee if there were items to be` -reviewed that we have not addressed above. Please contact Brook Marshall at. (760) 21.9-.8057 or by email at Brook do _zx.com with any questions or concerns. Sincerely, Hideaway Design Review Committee cc: 1ctTJacobmn t Nve Jaeobse» v' ' DRC Fite Tuesday, May 23; 2006 ,America Qzilzne: Woodardgrp 7 _ r a AWE - t tiric - o f . cAt�p gab& LWORPOMTED c ani oF�9�� -Building-A' Safety Department s. This Certificate is issued pursuant to the requirements of Section 109 of the California Building- Code, .certifying .that, at the -time of issuance, this structure was in 'compliance with the " provisions . of the Building Code and the .various ordinances of the City regulating building construction and/or use. " BUILDING ADDRESS: 80-753 VIA PESSARO Use classification: SFD Building.Permit No:: 05-3277 Occupancy Group:. R3 Type of Construction: VN - Land Use Zone: RL Owner of Building:` NRI CCP I Address: 81-100 AVE 53 o City, ST, ZIP: LA QUINT -A, CA 92253 By: EDDIE MUIR , . Date: JUNE 21, 2007 ' Building Official POST IN A CONSPICUOUS PLACE ' Bin # City of La Quinta Building u Safety Division Permit f12.p '} d 05 __3 P.O. Box 1504, 78-495 Calle Tampico - La Quinta, CA 92253 - (760) 777-7012- Building Permit Application and Tracking Sheet ' Project Address: 7 g' S✓ N �� Owner's Name: /11 —2 SP/t, A. P. Nufr4mber a ••r - Legal Description: r' Address: J ' City, ST, Zip: Contractor: k '�( 6A"e S Telephone: t Address: Project Description: •t .City, ST, Zip: Telephone: State Lic. # : City Lia #: Arch., Engr., Designer: d..,.� w Address: City,: ST, Zip: Telephone: Construction Type: Occupancy: P cy: State Lic. #: Project type{circle one): New Add, Alter Repair Demo Name of Contact Person: L Sq: Ft : # Stories: # Units: Telephone # of Contact Person: 3 7 6 �. Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE - .. # Submittal Plan Sets s+ 1 . Req'd. Reed TRACKING . Plan Check submitted %� PERMIT FEES Item Amount Structural Cities. Reviewed, ready for corrections �- Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy .Cxlcs. Plaits picked up_ U Construction Flood plain plan Plans resubmitted ll�% Mechanical Grading plan 2`' Review, ready for eorrecti . Fissue Electrical Subcontactor List Called Contact Person J L11 D Plumbing Grant Deed Plans picked up . S.M.I. H.O.A. Approval Pians resubmitted.. Grading INHOUSE:- "* Review, ready for correctionsliissue Developer Impact Fel:. ; Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue. School Fees ' ` ... Total.Permit Fees .• .. . _ _ aj., ' } -�i . w � i -TABLE OF CONTENTS ... ^ 4 ,. Cover Page Table of Contents 2 Form CF -1 R Certificate of Compliance y . ;- 3 Form MF -1 R Mandatory Measures Checklist _ '. - 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling, Loads -Summary • . ' ` 14 Room Load Summary ,' ' - r ` • 18 r, r EnergyPro 3.1 By EnergySoft . ► Job Number: « . User Number: 2655 4 ,. Certificate of Compliance: Residential (Part 1 of'2). CF -1 R Jacobsen Development.. 3/14/2006 Project Title • Date 80753 Via Pessaro La•Quinta •`� Project Address r �' ' Building Permit # Insu-Form Inc: (760) 324-0216 / Plan Check Date Documentation Author -� ' Telephone Computer Performance 15' Field check/ Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION '0.756 Total Conditioned Floor Area: �4,377fte '.: '; Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 4,377 ft2 - a ,1 Building Type: ► y -„ F +; �4.:. (check one or more) 0.028 ' t X❑ Single Family Detached '❑ Addition ❑ Single Family Attached ❑ Existing Building '; r' Multi -Family ❑ Existing Plus Addition 414.8 0:39 F' ' Front Orientation: (East) 90 deg Floor. Construction Type:Slab Floor Number of Dwelling Units: 1.00 , Number of Stories: 1 s� ;.} ❑ Raised Floor t (East) . 131.3 0.39 ---0.37 BUILDING SHELL INSULATION ` Orientation Const. Component Frame -Assembly Overhang Side Fins ` L Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a '0.756 • Exposed Slab MR -0.0 Perimeter Insulation R-19 Wall (W.19.2x6.16) Wood 0.065, Exterior Wall' R-38 Roof (R.38.2x14.16) Wood 0.028 ' Exterior Roof . Bug Screen a ❑ ❑. a Rear (West) 414.8 0:39 F' ' 0.37 - a Bug Screen X❑ ❑ ❑ X❑ Front (East) . 131.3 0.39 ---0.37 Bug Screen X❑ ❑ ❑ X❑ F FENESTRATION ' . 1. • Shadina Devices Type Orientation Area Fenestration Extefior Overhang Side Fins SF U -Factor .` SHGC Shading Yes / No Yes / No Right (North) 176.9 0.39 0.37 Bug Screen - X❑ ❑ ❑ X❑ Left (South) 237.0 0.39. 0.37 . Bug Screen a ❑ ❑. a Rear (West) 414.8 0:39 F' ' 0.37 - a Bug Screen X❑ ❑ ❑ X❑ Front (East) . 131.3 0.39 ---0.37 Bug Screen X❑ ❑ ❑ X❑ F El 1:1 ❑❑ 11 El El 1:1 ❑, ❑ ❑ ❑ El El ❑❑ �„. El El El El - _ ❑❑ El 1:1 ❑❑ 1-1 El %' El 1:1 1:1 El Run Initiation Time: 03/14/06 15:48:38 Ruh Code: 1142380118 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: ' Pa e:3 of 21 ' Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Jacobsen Development .A 3/14/2006 Project Title Date HVAC SYSTEMS Note: Input'Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution - Heating Equipment Minimum Type and i Duct or .- Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) . (AFUE/HSPF) (ducts, attic, etc.) R -Value Type - Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone 1 Central Furnace 80% AFUE Ducts in'Attic - 42. Setback Zone 2 - Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone 3 - `Centml Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone 4 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat • Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments ' Split Air Conditioner 12.0 SEER • Ducts in Attic 42. Sethack Zone 1 Split Air Conditioner '12 0 SEER Ducts in Attic 4 2 Sethack Znne 2 Split Air Conditioner. 12.0 SEER Ducts in Attic 4:2 Setback'- Zone 3 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 4 WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in • Input Cap.. or Recovery StandbyTank Insul. System Name Type Type Syst•Btu/hr (gal) Efficiency Loss (%) R -Value A.O SMITH FPS -75-230 Small Gas Standard ' ,l— " , 75,000 75 0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. ' RFMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the ti California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. , Designer or Owner (per Business & Professions Code) Documentation Author Name: "Slbr s%,%t ►'- C�rt/� ` Name:,' Joan D. Hacker ' Title/Firm: NiE `CoR-C)o® Title/Firm: ensu -Form Inc. _ Address: –M j Address: • 68255 Corta Road on Cai • - r Cathedral City, CA 92234 ' Tele (,D. i'7S-- 1(® Telephone: _(760) 324-0216 L' - v(� (signature) - (date) (sign ure (date) Enforcement Agency Name: Title/Firm: s ' Address: Telephone: ` (signature/stamp) (date) Code:Run Initiation Time: 03M4106 15:48:38 Run EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: PageA of 21 Certificate of Compliance: Residential (Addendum) CF -1 R Jacobsen Development 3/14/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to.be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building. or design that otherwise complies 'based on the adequacy of the special justification and documentation submitted.I Plan I Field The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 504 sqft Covered Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sqft Exposed Slab Floor, 3.50" thick at Zone 1 , The HVAC System "Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1024 sqft Covered Slab Floor, 3.50" thick at Zone 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sqft Exposed Slab Floor, 3.50" thick at Zone 2 The HVAC System "Zone 3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1224 sqft Covered Slab Floor, 3.50" thick at Zone 3 The HVAC System "Zone 4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1225 sqft Exposed Slab Floor, 3.50" thick at Zone 4 .f HERS Required Verification f These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan I Field The HVAC System "Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. t The HVAC System "Zone 4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide k verification of the TXV, or measure the Refrigerant Charge and Airflow. .' Kun Inniatlon lime: 03/14/06 15:48:38 ' Run Code: 1142380118 EnergyPro 3.1 By Energysoft User Number: 2655 - Job Number: Paae:5 of 21 0 i ' Mandatory Measures Checklist: Residential (Page 1, of 2) MF -1 R NOTE.. Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an - asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance., When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 2 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures . ❑X §150(.): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R -Value. *§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑X not apply to exterior mass walls). '§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. t ' §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ +' greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed e . §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. , § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ ' § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door s b. Outside air intake with damper and control c. Flue damper and control " 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. i §15o(j): Pipe and Tank Insulation. El 1. Storage gas water heaters rated with an Energy Factor.less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank: EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 21 • w Wndatory Measures Checklist: Residential' (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an f asterisk (') may be superseded by more stringent comp lance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ' I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system ' that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not , be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used.in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands., 4. Exhaust fan systems have back draft or automatic dampers. r 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. - F 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam. insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑§114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof, operating instructions, no electric resistance heating, and no pilot. ' 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. ' b. Cover for outdoor pools or outdoor spas.' 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no * ' continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specked criteria" s Lighting Measures j a§ 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for ' general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. Computer Method Summary (Part 1 of 3) C -2R -Jacobs-en-Development 1.93 1.89 —31-1-4.12-0-0-6— Project Title Space Cooling Date _8.0Z5.3_V__i a -Re s s aro—La_Qui nta —Setback_ 2 Domestic Hot Water Project Address -0.06 Building Permit # 1nS_u-Eorm Inr (760) 324-0216 1.54 Documentation Author Telephone Plan Check/Date _Computer-RerformIA 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone ❑ Source Energy Use Standard Proposed Compliance Floor Construction Type: ❑ (kBtu/sf-yr) Design Design Margin Single Fam Detached Space Heating 1.93 1.89 0.04 —Setback— _2 Space Cooling 32.45 30.90 1.56 —Setback_ 2 Domestic Hot Water 6.51 6.57 -0.06 Location / Comments Totals 40.89 39.35 1.54 ❑ Percent better than Standard: 3.8% BUILDING COMPLIES ❑ Total Conditioned Floor Area: 4,377 ft2 Floor Construction Type: ❑ Raised Floor Slab Floor Building Type: Single Fam Detached ❑ Building Front Orientation: (East) 90 deg Total Fenestration Area: 21.9% Number of Dwelling Units: 1.00 Total Conditioned Volume: 43,770 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 4,377 ft 2 BUILDING ZONE INFORMATION Zone Name Floor Area Volume Zone 1 7-one-2— OPAQUE one 2 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt X04 1_,224 1..225 Solar Gains Y/N 040 12,240 12,240 12,250 # of Units —01.6_ 028_ 0_28_ 028_ Form 3 Reference Zone Type Conditioned— Conditioned_ Conditioned_ Conditio aed_ Thermostat Vent Type Hgt. Area —Setback— _2 _n/a —Setback — 2 _n/a —Setback_ 2 —n/.a Setback_ 2 _n/a Location / Comments Wall— X03 Roof_ —204_ Wall_ 318_ Wall_ 303 Rooms 1496 Wall_ X1.9 Wall— —200 Root_ 1,224 Wall_ _29.0 Wall— x.8.5 Wall_ _2.82. Wall_ X20 _Roo. 1.225_ —0-065 0 —0-028_ 0_ —0_.0.6.5_ 1.80_ —0-065- _27-0- 0_028 _0__0 —0-065-90--9-0.. 0 065 _2ZQ —028-0 —0_0.6.5 90_ _0_0.6.5. 180_ 0 065 _270- —0-065 0- 0-028_ 0_ 90 0 9.0_ 90 90 0 90 _90 90 90 0 L& 1X IX X Iii X �� [)--Q A IN Q❑ LJ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ _Rd9_WalL(W_.19.2x616) R-38_Rooi(R_a8_ 1416a JR�t9_WaIL(W-.9.2x616.) -ELL9_WalL(W19 2x6]6) _R_38_Roo.L(R.38 2x14. JRt9_W..alL(W_19.2x616.) _R_1.9_WalL(W_ _9 2x616) .R_38BooUR.38 2x14._1.6) _R_1.9_WalL(W_19_2_x6_1_65)_ .EZ19_WalL(_W_19 2x616) _Rd9_Wall_(_W_J 9.2x616) _R19_WaIL(W19 2x616) R-38 R ooff (R.38.2x14.16) Zone 1 Zone 1 Zone 2 Zone 2 Zone 2 Zone_3 Zone_3 7-one_3 .Zone 4 Zone 4 Zone 4 Zone a Zone a ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ ❑❑ F1 F-1 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paoe:8 of 21 1 Computer Method Summary (Part 2 of 3) C -2R Jacobsen Development 3/14/2006 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1_ Window-Right-i(North) -25_0_ -0._390_ 0._37- 0_ _9.0. Sierra_eacif.c -Zone-1 2 Window Right (North) 12.6 0.390 0.37 0 90 Sierra Pacific Zone 1 3 Window Right (North) 11.3 0.390 0.37 0 90 Sierra Pacific Zone 1 4 Window Right (North) 48.0 0.390 0.37 0 90 Sierra Pacific Zone 1 5 Window Left South 54.0 0.390 0.37 180 90 Sierra Pacific Zone 2 6 Window Left (South) 48.0 0.390 0.37 180 90 Sierra Pacific Zone 2 7 Window Rear (West) 36.0 0.39Q 0.37 270 90 Sierra Pacific Zoe 2 8 Window Rear West_ 49.5 0.390 0.37 270 90 Sierra Pacific Zone 2 9 Win ow Rear (West). 11.3 0.390 0.37 270 90 Sierra Pacific Zone 2 _1.0 Window Front (East)_ 18.0 0.39.0 0.37 90 90 Sierra Pacific Zone 3 11 Window Front (East)_ 18.0 0.390 0.37 90 90 Sierra Pacific Zone 3 12 Window Front (East) 18.0 0.390 0.37 90 90 Sierra Pacific Zone 3 _1.3 Window Eront_(East 47,3 0-390 -0-37- 90_ 90 Sierra-P-adfiic _Zo3e_3 14 Window Rear (West) 200.0 0.390 0.37 270 90 Sierra Pacific Zone 3 15 Window Front (East) 30.0 0.390 0.37 90 90 Sierra Pacific Zone 4 16 Window Left (South) 5.0 0.390 0.37 180 90 Sierra Pacific Zone 4 17 Window Left (South) 25.0 0.390 0.37 180 90 Sierra Pacific Zone 4 18 Window Left (South) 20.0 0.390 0.37 180 90 Sierra Pacific Zone 4 1Q. Window Left (South) 22.0 -034 0.37 1$0_ 9Q Sierra Pacific Zone 4 20 Window Left (South) 9.0 0.390 0.37 180 90 Sierra Pacific Zone 4 21 Window Left (South) 25.0 0.390 0.37 180 90 Sierra Pacific Zone 4 .22 Window Left South 9.0 0.390 0.37 . 180 90 Sierra Pacific Zone 4 23 Window Left (South) 10.0 0.390 0.37 180 90 Sierra Pacific Zone 4 24 Window Left (South) 10.0 0.390 0.37 180 90 Sierra Pacific Zone 4 25 Window Rear (West) 24.0 0.390 0.37 270 90 Sierra Pacific Zone 4 26 Window Rear (West) 48.0 0.390 0.37 270 90 Sierra Pacific Zone 4 27 Window Rear (West) 24.0 0.390 0.37 270 90 Sierra Pacific Zone 4 28 Window Rear (West) 22.0 0.390 0.37 270 90 Sierra Pacific Zone 4 29 Window Right (North) 30.0 0.390 0.37 0 90 Sierra Pacific Zone 4 INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 3.0 1.0 0.1 1.0 1.0 2 Bug Screen 0.76 2.5 2.5 1.0 0.1 1.0 " 1.0 3 Bug Screen 0.76 8.0 2.5 6.0 0.1 6.0 6.0 4 Bug Screen 0.76 9.0 3.0 8.0 0.1 8.0 8.0 5 Bug Screen 0.76 9.0 4.0 1.0 0.1 1.0 1.0 6 Bug Screen 0.76 . -3-0 6.0 1.0 0.1 1.0 1.0 7 Bug Screen 0.76 9.0 2.0 10.0 0.1 10.0 10.0 8 Bug Screen 0.76 9.0 2.9 10.0 0.1 10.0 10.0 9 Bug Screen 0.76 4.5 2.5 1.0 0.1 1.0 1.0 10 Bug Screen 0.76 9.0 1.0 1.0 0.1 1.0 1.0 11B�cu Screen 0.76 9.0 2.0 1.0 0.1 1.0 1.0 12 Bug Screen 0.76 9.0 1.0 1.0 0.1 1.0 1.0 13 Bug Screen 0.76 9.0 2.5 1.0 0.1 1.0 _ 1.0 14 Bug Screen 0.76 10.0 20.0 14.0 -'0. 1 14.0 14.0 15 Bug Screen 0.76 6.0 3.0 1.0 0.1 1.0 1.0 16 Bug Screen 0.76 2.0 2.5 1.0 0.1 1.0 1.0 17 Bug Screen 0.76 5.0 5.0 1.0 0.1 1.0 _ 1.0 18 Bug Screen 0.76 5.0 2.0 1.0 0.1 1.0 1.0 19 Bug Screen 0.76 8.0 2.5 1.0 0.1 1.0 1.0 20B�cu Screen 0.76 4.0 2.5 1.0 0.1 1.0 1.0 21B�cu Screen 0.76 5.0 5.0 1.0 0.1 1.0 _ 1.0 22 Bug Screen 0.76 5.0 2.0 1.0 0.1 1.0 1.0 23 Bug Screen 0.76 4.0 2.0 1.0 0.1 1.0 1.0 24 Bug Screen 0.76 5.0 2.0 1.0 0.1 1.0 1.0 25 Bug Screen 0.76 8.0 1.5 1.0 0.1 1.0 1.0 26 Bug Screen 0.76 8.0 6.0 1.0 0.1 1.0 1.0 27 Bug Screen 0.76 4.0 1.6 1.0 0.1 1.0 1.0 28 Bug Screen 0.76 8.0 3.0 1.0 0.1 1.0 1.0 29 Bug Screen 0.76 5.0 3.0 1.0 0.1 1.0 1.0 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paoe:9 of 21 1 Computer Method Summary (Part 2 of 3) C -2R Jacobsen Development 3/14/2006 Project Title Date FENESTRATION SURFACES U- Act. , Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _3.0. W..indow_Etight (Lloith) —50_0_ — —0-390 "_0._37_ r 0_ _9.0. Sieua-Eacific -Zone-4 • INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 8.0 6.0 1.0 0.1 1.0 1.0 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paw 10 of 21 1 I EnergyPro 3,1 By Energysoft User Number: 2655- Job Number:. Page: 11 of 21 Computer Method Summary - (Part 3•of 3), C -2R Jacobsen Development ' .:. • .t 3/14/2006. Project Title f Date THERMAL MASS FOR HIGH MASS DESIGN • ' ' Area Thick. Heat Inside Location = , „ Type (so (in.) Cap. .Cond.. Form 3 Reference R -Val Comments ' Concrete Heavyweight -5.04 _3.50 =28. ' ._0.-R8. n/.a _ '_2. Zone_LLSlab-on Grade' Concrete—Heavyweight' 200 . 3_50 28 0.98 n/a 0 Zone 1 / Slab on Grade Concrete Heav)nn_/eight 1 024 3;50 28 0.98 n/a °_ 2 - Zone/ Slab on G-ar de Concrete. Heavyweight 200 3_50 28 0.98 n/a - " 0 _2 Zone 2 / Slab on Grade Coactete }ieavyweight 1 224 3.50 28 98 n/a 2 Zone 3 / Slab on Grade " i-• PERIMETER LOSSES f F2 Insulation i Type Length Factor ' R -Val. Depth ' Location / Commentsj. ' > Slab Perimeter 18 0�7 0.0 _0 Q. Zone 1 Stab-Bedmeter _1.5 _01-6 —0-0. ','_0 Zone -1 " Slab Perimeter • ° 18 -D-76 0, 0 Zone 2 S1ab_Be-rimeter. _1_S _01-6 _0_0 ; •_0 Zone -2 .Slab-Eeumeter 18 ` 0-7 0.0 0 -. Zone 3 , ~ `• .>+.: HVAC SYSTEMS , < y / Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat ` t Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.). R -Value Type- Comments i `Central furnace 803AF E Ducts in Attic 4.2 Setback Zone 1 ' Central Furnace - 80%AFUE Ducts in Attic 4.2 _ Setbacks y Zone 2 Central Furnace .80% AFLIE Ducts in Attic- 4.2 ' Setback Zone 3 Central Furnace 80% AFUE Ducts in Attic ` ' 4.2 '. Setback Zone 4 Hydronic Piping Pipe Pipe Insul. ' System Name Length' Diameter, Thick: Cooling Equipment Minimum 3Duct Type (air conditioner, "Efficiency . Location Duct Thermostat Location / heat pump, evap. cooling) • (SEER) , (attic, etc,)' R-Value*Type ' Comments - Split Air Conditioner 1ZQ SEER Ducts in Attic ' 4.2 Setback Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback - Zone 2 ' Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 1 Setback Zone 3 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 'Setback = Zone 4 `• WATER HEATING SYSTEMS ~ ' a Ratedl f Tank Energy Facts 1 Tank Insul. Water Heater, Water, Heater Distribution •• # in Input • Cap.. or Recovery Standby R -Value System Name ` ° Type . Type,,,. Syst. (Btu/hr)'; "; (gam - .Efficiency • Loss (%) Ext. A.O. SMITH FPS -75-230 . 'Small Gas ' * Standard` 11 75,000 75 0.52 n/a . 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. ,For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. ' For instantaneous gas water heaters, Iisf Rated Input, and Recovery Efficiency. REMARKS _ G..w Iw:.:...:.... T:....., A7/Al/AC AG.I O.•10 �..� l.�J�. AA IA•l�/.IA� ' , . I EnergyPro 3,1 By Energysoft User Number: 2655- Job Number:. Page: 11 of 21 Computer Method Summary ' r (Part 3 of 3) C -2R •Jacobsen Development 3/14/2006 Project Title F +^ t Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val Comments % _Concrete, Heavyweight _1.,225 _3..5.0 _28:. _0_98. n/.a _0. ZoneA/_Slab_on Grade PERIMETER LOSSES F2 _ Insulation Type Length . Factor R -Val Depth ` Location ! Comments Slab Perimeter 15-Q. —7Q �0 _0 Zone 4 HVAC SYSTEMS ` Heating Equipment Minimum ,Distribution Type Type (furnace; heat ,Efficiency and Location Duct y. -Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value -Type. •' Comments ` Hydronic Piping, Pipe ` ' Pipe. ; '.1 Insul.`' System Name Length Diameter Thick.... Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location' . Duct .,, .Thermostat Location ! r heat pump, evap. cooling) (SEER) (attic,'etc) R;Value' Type Comments .. , S • • 4 WATER HEATING SYSTEMS Rated/ Tank Energy Facts 1`Tank Insul. Water Heater Water Heater Distribution • #'In Input Cap. or RecoveryStandby R -Value System Name Type Type Syst: Btu/hr)gal) Efficiency Loss (%) Ext.. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and{heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and,Recovery Efficiency. REMARKS Run Initiation Time: 03/14/06 15:48:38 Run Code: 1142380118 EnergyPro 3.1- By EnergySoft '' User Number: 2655,Job Job Number: Page: 12 of 21 Computer Method Summary, (Addendum) C -2R Jacobsen Development 3/14/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I pia„ F;Pid The DHW System "A.O. SMITH FPS -75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 504 sqft Covered Slab Floor, 3.50" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 soft Exposed Slab Floor; 3.50" thick at Zone 1 The HVAC System "Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1024 sqft Covered Slab Floor, 3.50" thick at Zone 2 ' HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sqft Exposed Slab Floor, 3.50" thick at Zone 2 The HVAC System "Zone 3" includes credit fora Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1224 sqft Covered Slab Floor, 3.50" thick at Zone 3 The HVAC System "Zone 4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1225 sqft Exposed Slab Floor, 3.50" thick at Zone 4 HERS Required Verification r s These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan Field The HVAC System "Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A.certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. * ' The HVAC System "Zone 4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow: - i Run Initiation Time: 03/14/06 15:48:38 Run Code: 1142380118 :nergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 13 of 21 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jacobsen Development 3/14/2006 SYSTEM NAME FLOOR AREA Zone 1 704 Number of Systems 1 Heating System Output per System 70,000 Total Output (Btuh) 70,000 Output (Btuh/sgft) 99.4 Cooling System Output per System 22,600 Total Output (Btuh) 22,600 Total Output (Tons) 1.9 Total Output (Btuh/sgft) 32.1 Total Output (sgft/Ton) 373.8 Air System CFM per System 1,595 Airflow (cfm) 1,595 Airflow (cfm/sgft) 2.27 Airflow (cfm/Ton) 846.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions EATING S 26.0 of >--O Outside Air 0 cfm 69.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I.Sensiblel Latent CFM I Sensible 11744 10,949 1,673 267 11,526 0 78.3/69.0 OF 78.3/69.1 OF 71.8/66.7 OF 547 576 0 0 0 0 011 0 0 0 0 cfm 0 547 576 12,0441 1,6731 12 679 RHEEM RAMB-024J` 11,108 10,390 70,000 Total Adjusted System Output 11,1081 10,390 70,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am -earn Temperatures at Time of Heating Peak) 69.7 of 69.7 °F ® 1110.90F Supply Fan Heating Coil 1595 cfm Return Air Ducts Supply Air Ducts 110.6 OF ROOMS 70.0 OF I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 111.9/77.6 OF 78.3/69.0 OF 78.3/69.1 OF 71.8/66.7 OF Supply Air Ducts —W Outside Air 0 cfm Supply Fan Cooling Coil 72.1 / 66.8 of 1595 cfm ROOMS 63.8% R.H. of 78.0 / 68.9 of 78.3/69.0 Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 14 of 21 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jacobsen Development 3/14/2006 SYSTEM NAME FLOOR AREA Zone 2 1,224 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems III COIL COOLING PEAK COIL HTG. PEAK 1 Heating System Output per System 70,000 Total Output (Btuh) 70,000 Output (Btuh/sgft) 57.2 Cooling System Output per System 46,500 Total Output (Btuh) 46,500 Total Output (Tons) 3.9 Total Output (Btuh/sgft) 38.0 Total Output (sgft/Ton) 315.9 Air System CFM per System 1,595 Airflow (cfm) 1,595 Airflow (cfm/sgft) 1.30 Airflow (cfm/Ton) 411.6 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 19_T01X0111111:2J,I=U'll 1,122 19,557 CFM I Sensible Latent I CFM I Sensible 1,122 19,557 2,909 423 18,084 0 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling 978 904 0 0 0 0 0 0 0 0 4 Supply Air Ducts 0 978 904 21 513 2 909 19 892 RHEEM RAMB-048J' 29,764 12,615 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Total Adjusted System Output 29,76a (Adjusted for Peak Design Conditions) 12,615 70,000 70,000 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 1HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 26.0 of 69.5 of 69.5 of 110.70F O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 110.2 °F 1595 cfm ROOMS 69.5 of 70.0 of EnergyPro 3.1 By EnergySoft User Number: 2655. Job Number: Page: 15 of 21 Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.9 / 77.6 of 78.6 / 66.5 of 78.6 ! 66.5 of 61.0 60.1 of 310 4 Supply Air Ducts O Outside Air 0 cfm Supply Fan Cooling Coil 61.6 60.3 of 1595 cfm ROOMS 54.5% R.H. of 78.0 / 66.3 of 78.6/66.5 Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 2655. Job Number: Page: 15 of 21 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jacobsen Development 3/14/2006 SYSTEM NAME FLOOR AREA Zone 3 1,224 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensiblel Latent 1, CFM I Sensible 895 22,266 2,909 427 18,253 0 1,113 913 0 0 0 0 0 0 0 0 0 1,1131 1 913 24,492 2,909 RHEEM 12AJA6001 41,912 4,230 Total Adjusted System Output 41,912 4,230 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm F777;:078 70,000 70,000 Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temneratures at Time of Heating Peak) I 26.0 of 69.5 of 69.50F ® 110.70F Outside Air 0 cfm Supply Fan Heating Coil 1595 cfm 69.5 of Supply Air Ducts 110.2 of ROOMS 70.0 of Return Air Ducts I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 11.9/77.6OF 78.7/62.5OF 78.7/62.6OF ■ 54.0/52.7OF Outside Air 0 cfm 78.7/62.5 of Supply Fan Cooling Coil 1595 cfm Return Air Ducts Supply Air Ducts 54.6/52.9OF 41.4% R.H. ROOMS 78.0 / 62.3 of EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 16 of 21 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Jacobsen Development 3/14/2006 SYSTEM NAME FLOOR AREA Zone 4 1,225 SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,561 26,630 2,912 523 22,235 0 1,331 1,112 0 0 0 0 0 0 0 0 0 1,331 1,112 29,2931 2,9121 1 24 458 RHEEM RAMB-048J' 29,878 12,596 70,000 Total Adjusted System Output 29 878 12,596 70,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 1HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 26.0 OF 69.3 OF 69.3 OF 110.6 °F O Outside Air Supply Air Ducts 0 cfm 109.9 OF Supply Fan Heating Coil 1595 cfm ROOMS 70.0 OF 69.3 OF 1% Return Air Ducts `i (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 11.9/77.6°F 78.8/66.6°F 78.8/66.7°F . 61.2/60.2°F Outside Air 0 cfm 78.8/66.6 °F Supply Fan 1595 cfm Cooling Coil h Return Air Ducts `i Supply Air Ducts --- 62.0160.5 of 54.8% R.H. ROOMS 78.0 / 66.4 OF EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 17 of 21 � l3 ROOM LOAD SUMMARY PROJECT NAME Jacobsen Develo ment DATE 3/14/2006 SYSTEM NAME Zone1 FLOOR AREA 704 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE -Zone 1 Zone 1 1 1,744 10,949 1,673 1,744 10,949 1,673 267 11,526 K r r, ~ PAGE TOTAL 1 1,744 10,949 1,673 267 11,526 TOTAL 1,7441-10,949 1,673 267 11,526 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 18 of 21 ROOM LOAD SUMMARY ` 'h ' EnergyPro 3.1 By EnergySoft UserNumber: 2655 Job Number: Page: 19 of 21 ROOM LOAD SUMMARY R PROJECT NAME DATE Jacobsen Development 3/14/2006 SYSTEM NAME FLOOR AREA Zone 3 1,224 EnergyPro 3.1 By EnergySoft ' User Number: 2655 Job Number: Page:20 of 21 I ROOM LOAD SUMMARY- ` EnergyPro 3.1 By Energysoft User Number: 2655. Job Number: Page:21 of 21 r