06-0876 (SFD)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description
Property Zoning:
Application valuation:
Applicant:
[06-=00-0-0087-6�
80486 VIA PESSARO
777-180-009- - -
DWELLING - SINGLE FAMILY
LOW DENSITY RESIDENTIAL
44bU55
I hereby affirm under penalty of perjury that I
Section 7000) of Division 3 oL jE BeeiapCC
License Class: 13
Date: S'.L� Y�Contra on
Tit!t 4 4& Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
WAYNE & LAURA BELLOWS
60 HARBOR COVE WY
DETACHED MILL VALLEY, CA 94941
Architect or Engineer:
W /1-0`
IT
i
is DECLARATION
visions of -Chapter 9 (commencing with
, and my License is in full force and effect.
No.: 518713
%WNER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Contractor:
JONES DESIGN/CNST INC, STEPHEN
P.O. BOX 4656
PALM DESERT, CA 92261
(760)346-3366
Lic. No.: 518713
'0
_J
Date: 5/25/06
MAY 2 6 2006
CITY OF 15i
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
�f issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy nu bar are:
Carrier ST TE FUND licy Number 769293-2006
i certify that, in the performance o t work for whi h this permit iS iSSued, I Shall not employ any
person in any manner so as to b come subj t workers' compensation laws of California,
and agree that, if I should ject th kers' compensation provisions of Section
3700 of the e, I hwith omp h those provisions.
nnli—v c
WARNING: FAILURE TO SECURE WORKERS' COMAPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application become II and void if w rk is not commenced
within 180 days from date of issuance of such permit, r essation of wo for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above in�ect
ation�scorrect. I agree to comply with all
city and county ordinances and to laws relating to building conson, ltd hereby thorize representatives
of this county to enter upo a above-mentione rLpu os s.
(Applicant or Agent):
Application Number . . . . . 06-00000876
Permit
. . .
BUILDING PERMIT
Additional
desc .
Permit Fee
1854.00
Plan Check Fee
1205.10
Issue Date
. . . .
Valuation . . . .
446055
Expiration
Date . .
11/21/06
Qty Unit Charge
Per
Extension
BASE
FEE
639.50
347.00
3.5000
THOU BLDG
100,001-500,000
1214.50
Permit
. . .
MECHANICAL
Additional
desc .
Permit Fee
. . . .
186.00
Plan Check Fee
46.50
Issue Date
. . . .
Valuation
0
Expiration
Date . .
11/21/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
5.00
9.0000
EA MECH
FURNACE <=100K
45.00
2.00
9.0000
EA MECH
B/C <=3HP/100K BTU
18.00
3.00
16.5000
EA MECH
B/C >3-15HP/>100K-500KBTU
49.50
8.00
6.5000
EA MECH
VENT FAN
52.00
1.00
----------7-----------------------------------------------------------------
6.5000
EA MECH
EXHAUST HOOD
6.50
Permit
. . .
ELEC-NEW RESIDENTIAL
Additional
desc . .
Permit Fee
. . . .
233.48
Plan Check Fee
58.37
Issue Date
Valuation . . . .
0
Expiration
Date
11/21/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
4748.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
166.18
1865.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
37.30
1.00
----------------------------------------------------------------------------
15.0000
EA ELEC
TEMPORARY POWER POLE
15.00
Permit . . . PLUMBING
Additional desc . .
Permit Fee . . . . 234.00
Issue Date
Expiration Date 11/21/06
Qty Unit Charge Per
BASE FEE
LQPERMIT
Plan Check Fee . . 58.50
Valuation . . . . 0
Extension
15.00
Application Number . . . . . 06-00000876
Permit . . . . PLUMBING
Qty Unit Charge
Per
Extension
25.00 6.0000
EA PLB FIXTURE
150.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
2.00 7.5000
EA PLB WATER HEATER/VENT
15.00
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
16.00 .7500
EA PLB GAS PIPE >=5
12.00
1.00 15.0000
----------------------------------------------------------------------------
EA PLB GAS METER
15.00
Permit . . .
GRADING PERMIT
Additional desc . .
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . .
. 0
Expiration Date . .
11/21/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
--------------------------- ------------------------------------------------
Special Notes and Comments
4748 SQ FT. SFD PERMIT DOES NOT INCLUDE
BLOCK WALLS OR POOL/SPA
May 12, 2006
1:42:52 PM SRUBIO
----=-----------------------------------------------------------------------
Other Fees . . . . .
. . . . ART IN PUBLIC PLACES -RES
615.13
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
480.00
ENERGY REVIEW FEE
120.51
DIF FIRE PROTECTION -RES
140.00
DIF LIBRARIES - RES
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC - RES
892.00
STRONG MOTION (SMI) - RES
44.60
DIF STREET MAINT FAC -RES
67.00
DIF TRANSPORTATION - RES
1666.00
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total
2522.48 .00 .00
2522.48
Plan Check Total
1368.47 1000.00 .00
368.47
Other Fee Total
4476.24 .00 .00
4476.24
Grand Total
8367.19 1000.00 .00
7367.19
LQPERMIT
P.O. BOX 1504 APPLICATION ONLY Q�
Building ` U I/ 78-495 CALLE TAMPICO
Address ( J LA QUINTA, CALIFORNIA 92253
OwnU]W)
L d ` �� BUILDING: TYPE CONST., OCC. GRP.
Mailing � . S i j
Address O �% W� A.P. Number
•
I y j Zip/ C�{+ Legal Descriptionlzf l i
CoMriic, r ,- _ C ,_T„r ,�A A_ ..-4 _ Project Description
Zi
estate LIC. L Ity
& Classif. SI I Lic. #
L'ITY Lip Mate
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penally of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractors) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, Slate, Zip
WHITE = BUILDING DEPARTMENT
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE
Issued by:
Validated by:_
Validation:
YELLOW = APPLICANT
Ir1SPECTO
Date Permit
PINK = FINANCE
Sq. �Oylv
Size
(10 No. Dw.
`-_es Units
New Add
Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
AMOUNT
Plan Chk. Dep.
Q 00, UO
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
Ilu
LUUU
CITY OF
FINANCE DEPT
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE
Issued by:
Validated by:_
Validation:
YELLOW = APPLICANT
Ir1SPECTO
Date Permit
PINK = FINANCE
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MTIGATION AMOUNT:
COMM/IND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: WW e/ Laura Bellows _(Residence _@ Hideaway) Date: 05/09/06
Owner's Name: Wayne/ Laura Bellows Phone No. (714) 632-6680
Project Address: 80-486 Via Pessaro, La Quinta, CA 92253
Project Description: 1 Single Family Dwelling
ATN: 772-520-049
Tract #:
Type of Development: Residential XX Commercial
Total Square Feet of Building Area: 4,748 sq. Ft.
Certification of Applicant/Owners: The person signing certifies that the a�ove info
penalty of perjury and further represents that he/she is authorized to sign on bphalf of
Dated: 05/09/06
Signature:
Lot #'s:
Industrial
correct and makes this statement under
*************************************************\J******:****************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Number of Sq.Ft. 4,748 sq. ft.
Amount per Sq.Ft. $ 2.63
Amount Collected $ 12,487.24
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., Business Services
Certificate issued by: Leticia C. Torres, Facilities Analyst
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other a.3plicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as terein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts oa the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
I_T:c/mydocs'devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T
RECORDING REQtIM90 BY:
New Century Title Company - Riverside Title
ORDER NO.: 2350303
ESCROW NO.: 33041526 -SP
AND WHEN RECORDED MAIL TO:
Wayne H. Bellows
Laura F. Bellows
60 Harbor Cove Way
MITI Valley, CA 94941
DOC ss Z00S-0006823
01/04/2005 08:00A Fee:7.00
Page 1 of 1 Doc T Tax Paid
Recorded 1n Official Records
County of Riverside
Assessor, County Clerk 8 Recorder
111111111111111111111111111111111111011111111111111111
M
S
U
PAGE SIZE
OA
aCOR
NOCOR
SMF MBC.
A
R
L
COPY I
LONG
REFUND • NCHO
GRANT Veeu
THE UNDERSIGNED GRANTOR(S) DECLARE(S) that documentary transfer tax Is $687.50 (County) $.00 (City)
( X) computed on full value of property conveyed, or
( ) computed on full value less liens or encumbrances remaining at time of sale
( X) City of La Quinta
FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, Dan R. Anderson and Patricia
Ann Anderson, Trustees of the Dan R. -Anderson Family Trust dated June 19, 2002, who erroneously acquired title as:
Don R. Anderson and Patricia Ann Anderson, Trustees of the Don R. Anderson Family Trust dated June 19, 2002,
hereby GRANT(S) to Wayne H. Bellows and Laura Fly Bellows, husband and wife as community
property
the following described real property in the City of La Quinta, County of Riverside, State of California:
PARCEL 1:
LOT 184 OF AMENDED TRACT NO. 29094-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA,
AS PER MAP RECORDED IN BOOK 327, PAGES 56 THROUGH 86, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY
RECORDER OF SAID COUNTY.
EXCEPTING THEREFROM TO GRANTOR, AND ITS SUCCESSORS AND ASSIGNS, INTEREST IN ALL WATER, MINERALS,
OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR
UNDER SAID LAND OR WHICH MAY BE PRODUCED FROM SAID LAND.
PARCEL 2:
NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER
PURPOSES, ALL AS DESCRIBED IN THE DECLARATION.
Dated: November 8, 2004
STATE OF CALIFORNIA
COUNTY PF
On l VB r?kn 9. 2tlt
Personally
before me hney, an R. Anderson, Trustee
0-r7
Personally known to me (or proved to me on the basis of satisfactory
evidence) to be the person(s) whose name(s) is/are subscribed to the
within Instrument and acknowledged to me that hQhpP-/they executed the
same In hWhw/their authorized capacity(ies), and that by hisfMeytheir
signature(s) on the instrument the person(s) or the entity upon behalf of
which the person(s) acted, executed the instrument.
WITNESS my har1d and official seal.
4 1 � " - d" I /" . " /' / -
Patricia Ann Anderson, Trustee
JUDITH A. KENNEY
o COMM. #1416627
NOTARY PUBUC -CALIFORNIA O
SAN JOAOUIN COUNTY
My Cortmdssion Eyoife$ May B, 2007
(This area for aRkial notary seal)
— Individual (290) 10-04 MAIL TAX STATfIMENTS AS DIRECTED ABOVE
,- Certificate of Occupancy
�� -�
INca�osnrtnG4�
G� OF'TBuildin & Safet Department
9► Y p
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 80486 VIA PESSARO
Use classification: SFD Building Permit No.: 06-0876
Occupancy Group: R3U1 Type of Construction: VN Land Use Zone: RL
Owner of Building: WAYNE & LAURA BELLOWS Address: 80486 VIA PESSARO
City, ST, ZIP: LA QUINTA CA 92253
By: EDDIE MUIR
Date: 08-22-07
Building Official
POST IN A CONSPICUOUS PLACE
I TITLE 24 REPORT I
Title 24 Report for:
The Bellows Residence
80-486 Via pessaro
La Quinta, CA 92253
Project Designer:
Stephen Jones
Po Drawer 4656
Palm Desert, CA 92261
(760) 346-3366
Report Prepared By:
Brad Stone
BREEZE AIR CONDITIONING
75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
(760) 346-0855
Job Number:
Date:
5/3/2006
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA 4/i O BY .s
o�CG� ea^.PY
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.1 by EnergySoft Job Number: User Number: 3665
,-�
TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
Form WS -5R Residential Kitchen Lighting
HVAC System Heating and Cooling Loads Summary
Lighting Specifications
Glazing Performance Ratings
HVAC Specifications
HVAC ARI Ratings
1
2
3
12
14
15
20
22
25
37
I EnergyPro 4.1 by EnergySoft Job Number: User Number: 3665 1
Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R
The Bellows Residence
Building Type: [j] Single Family
❑ Addition
5/3/2006
Project Title
ft2
❑ Multi Family
❑ Existing + Add/Alt
Date
130-486 Via nessaro
La Gluinta
Building Front Orientation:
(SE) 135 deg
Raised Floor Area:
Project Address `
ft2
Fuel Type:
Natural Gas
Building permit #
AIR CONDITIONING
ft2
Fenestration:
(760) 346-0855
Average Ceiling Height:
_BREEZE
Documentation Author
ft
Area: 1,486 ft 2
Telephone
Plan Che-.k/Date
EvPro
Compliance Method
Ratio: 31.3% Avg. SHGC: 0.29
15
Climate Zone
2
Field Check/Date
BUILDING ZONE INFORMATION
TDV EnergyUse
Standard
Proposed
Compliance
Floor Area Volume
(kBtulsf-yr
Design
Design
Margin
HVAC #1
HVAC #2
Space Heating
5.80
6.26
-0.46
HVAC #3
Space Cooling
64.65
62.10
2.55
HVAC #4
Fans
9.60
9.36
0.24
OPA UE SURFACES
Domestic Hot Water
5.09
7.29
-2.20
Pumps
0.00
0.00
0.00
Totals
85.14
85.01
0.13
r than Standard:
0.2%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Building Type: [j] Single Family
❑ Addition
Total Conditioned Floor Area:
4,748
ft2
❑ Multi Family
❑ Existing + Add/Alt
Existing Floor Area:
n/a
ft2
Building Front Orientation:
(SE) 135 deg
Raised Floor Area:
816
ft2
Fuel Type:
Natural Gas
Slab on Grade Area:
3,932
ft2
Fenestration:
Average Ceiling Height:
10.6
ft
Area: 1,486 ft 2
Avg. U: 0.40
Number of Dwelling Units:
1.00
Ratio: 31.3% Avg. SHGC: 0.29
Number of Stories:
2
BUILDING ZONE INFORMATION
# of Thermostat
Vent
Zone Name
Floor Area Volume
Units Zone Type Type
Hgt.
Area
HVAC #1
HVAC #2
1 276 17 760
1,513 19,669
n 27 Cnndifinned Selhark
032 Conditioned Setback
$
8
n/a
n/a
HVAC #3
1.143 11.5
0.24 Conditioned Setback
8
n/a
HVAC #4
387 3-096
0.08 Conditioned Setback
8
n/a
OPA UE SURFACES
Q Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Roof Wood 1 260 _ 0 025 R_38 R-0 0 55_�
Wall Wood 129 0.069 R_21 R-0.0 115 9
Wall Wood 494 0.069 R_21 R-0.0 205 go
Wall Wood 22 0 069 X71 R-0 0 295 9
Wall Wood 542 0.069 R_21 R-0.0 95_ go
Roof Wood 1.S13 0.025 R_38 R-0.0 -55 0
Wall Wood 138 0 069 R_21 R-0 0 115 9Q
Wall Wood 338 0 069 R_21 R_0 0 905 A
Wall Wood 60 0.069 R_21 R-0.0 250 9
Wall Wood 368 0069 R_21 R-0.0 295 90
Wall Wood 58 0 069 R-21 R_0 0 340 9
Wall Wand 338 0 069 R_21 R-0 n 25 gn
Roof Wood 1,143 0.025 R_38 R-0.0 55 0
Wall Wood 538 0.069 R_21 R-0.0 70 90
Wall Wood 176 0069 R_21 R-0.0 160 90
Door None 24 0.500 None R-0.0 160 90
Wall Wood 670 0069 R_91 R-0.0 9 S 0 9
Wall Wond 87 0 069 _$_21 R-0 0 340 _0
Roof Wood 387 n 025 R_38 R-0 0 S5 Q
Wall Wood 110 0069 R_21 R-0.0 70 9
Wall Wood 144 0"069 R_21 R-0.0 160 90
Wall Wood 144 0.069 R_21 R-0.0 250 _90
Wall Wood 124 0.069 R_21 R-0.0 340 90
Floor Wood 387 0 Q97 R_38 R_0 0 n is()
Roof Wood 429 n 025 R_38 R_0 0 Sri 0
Gains Condition
Y / N Status JA IV Reference Location / Comments
Run Initiation Time: 05/03/06 07:23:18 Run Code: 1146666198
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:3 of 39
Certificate Of Compliance :
Residential
Building Type: Y Single Family
(Part 1 of 4) CF -1 R
The Rpllows Residence
Project Title
4,748
ft2
❑ Multi Family
5/3/2006
Date
Via nessaro
La Qtjinta
ft2
Building Front Orientation:
(SE) 135 deg
_80-486
Project Address
816
ft2
Fuel Type:
Building Permit #
RRFFZF AIR CONDITIONING
3,932
ft2
(760) 346-0855
Documentation Author
10.6
ft
Telephone
Plan Check/Date
_FnergyPra
Compliance Method
1.00
15
Climate Zone
Field Check/Date
TDV EnergyUse
Standard
Proposed Compliance
(kBtu/sf-yr
Design
Design
Margin
Units Zone Type Type
n na Cnnditipned_ 15,zthank
Space Heating
5.80
6.26
-0.46
Space Cooling
64.65
62.10
2.55
Fans
9.60
9.36
0.24
Domestic Hot Water
5.09
7.29
-2.20
Pumps
0.00
0.00
0.00
Totals
85.14
85.01
0.13
Percent better than Standard: 0.2%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Building Type: Y Single Family
❑ Addition
Total Conditioned Floor Area:
4,748
ft2
❑ Multi Family
❑ Existing + Add/Alt
Existing Floor Area:
n/a
ft2
Building Front Orientation:
(SE) 135 deg
Raised Floor Area:
816
ft2
Fuel Type:
Natural Gas
Slab on Grade Area:
3,932
ft2
Fenestration:
Average Ceiling Height:
10.6
ft
Area: 1,486 ft2
Avg. U: 0.40
Number of Dwelling Units:
1.00
Ratio: 31.3% Avg. SHGC: 0.29
Number of Stories:
2
BUILDING ZONE INFORMATION
# of Thermostat
Vent
Zone Name
HVAC: #S
Floor Area Volume
429 141
Units Zone Type Type
n na Cnnditipned_ 15,zthank
Hgt.
$
Area
n/a
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Wall Wood 110 0 069 R_21 R-0 0 7n gn
Wall Wood 128 0.069 R-21 R-0.0 160 gn
Wall Wood 110 0-069 R-21 R-0.0 250 90
Wall Mod 10A 0 069 �$21 R-0 0 34n gn
Floor Wood 429 0.027 R_38 Ran n 180
Run
Gains Condition
Y / N Status JA IV Reference Location / Comments
®
11 New 09-A6 70WF #5
El New 09-A6 ZONE #5
® El New 09-A6 ZONE #5
IX 1:1 New 09-A6 ZONF #5
❑ ®New 21-A16 ZONE #5
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:4 of 39 1
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
The Bellows Residence 5/3/2006
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
1
dight
Right
(NE)
_1EQ 0.80 NFRC 0 43 NFRC 55_ 0 New Bristnlite Skylight
ZONE #1
2
Window
Front
(SE)
24.0 0.720 116-A 0.70 116-B
115
90 New
Double Metal Lo/E Door
ZONE #1
3
Window
Left
(SW)
15.5 0.340 NFRC 0_28 NFRC
205
90 New
Loewen CA2
ZONE #1
4
Window
Left
(SW)
150.0 0.720 116-A 0.70 116-B
205
90 New
Double Metal WE Door
ZONE #1
5
Window
Left
(SW)
40.0 0.350 NFRC 0.20 NFRC
205
90 New
Loewen French Door
ZONE #1
6
Window
Left
(SW)
10.7 0.350 NFRC 0_36 NFRC
205
90 New
Loewen Transom
ZONE #1
7
Window
Left
(SW)
40.0 0.350 NFRC 0_20 NFRC
205
90 New
Loewen French Door
ZONE #1
8
Window
Left
(SW)
10.7 0.350 NFRC 0.36 NFRC
205
90 New
Loewen Transom
ZONE #1
9
Window
Left
(SW)
4.0 0.340 NFRC0 28 NFRC
205
90 New
Loewen CA1
ZONE #1
1Q
Window
Right
(NE)
8.3 0_340 NFRC 0_28 NFRC
25
90 New
Loewen CA1
ZONE #1
11
Window
Right
(NE)
24.0 0.350 NFRC 0_20 NFRC
25
90 New
Loewen French Door
ZONE #1
12
Window
Right
(NE)
5.0 0.340 NFRC 0_28 NFRC
25
90 New
Loewen CAI
ZONE #1
-Q
Window
Right
(N E)
13.1 0.340 NFRC 0_28 NFRC 25_ 90 New Loewen CA1
ZONE #1
14
Window
Right
(NE)
5.0 0.340 NFRC 0.28 NFRC
25
90 New
Loewen CA1
ZONE #1
15
Window
Right
(NE)
13.1 0.340 NFRC 0.28 NFRC
25
90 New
Loewen CA1
ZONE #1
16
Window
Right
(NE)
15.0 0.340 NFRC 0_28 NFRC
25
90 New
Loewen CA1
ZONE #1
17
Window
Right
(NE)
31.5 0.330 NFRC 0_36 NFgc,
25
90 New
Loewen Picture
ZONE #1
18
Window
Right
(NE)
15.0 0.340 NFRC 0.28 NFRC
25
90 New
Loewen CA1
ZONE #1
19
Window
Right
(NE)
5.0 0.34 NFRC 0_28 NFRC 25
90 New
Loewen CA1
ZONE #1
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
19
INTERIOR AND EXTERIOR SHADING
Insulation
None No Insulation
26-A1
New
Condition
Slab Perimeter
45
None No Insulation
Window
Location/
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt. LEA
REA Dist. Len. Hgt. Dist. Len. Hgt.
1
None
1.00
2
Bug Screen
0.76
8.0
3.0
4.0
0.1 4.0
4.0
3
Bug Screen
0.76
4.6
3.3
12.0
0.1 12.0
12.0
4
Bug Screen
0.76
10.0
15.0
12.0
0.1 _ 12.0
12.0
5
Bug Screen
0.76
8.0
5.0
12.0
0.1 12.0
12.0
6
Bug Screen
0.76
2.0
5.3
12.0
0.1 12.0
12.0
7
Bug Screen
0.76
8.0
5.0
12.0
0.1 12.0
12.0
8
Bug Screen
0.76
2.0
5.3
12.0
0.1 12.0
12.0
9
Bug Screen
0.76
2.0
2.0
12.0
0.1 12.0
_
12.0
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
Slab Perimeter
Insulation
None No Insulation
26-A1
New
Condition
Slab Perimeter
45
None No Insulation
PERIMETER LOSSES
Location/
Type Length R -Val.
Location
JA IV Reference Status
Gomments
Slab Perimeter
105
None No Insulation
26-A1
New
ZONE #1
Slab Perimeter
45
None No Insulation
26-A1
New
ZONE #1
Slab Perimeter
91
None No Insulation
26-A1
New
ZONE #2
Slab Perimeter
39
None No Insulation
26-A1
New
ZONE #2
Slab Perimeter 112 None No Insulation 26-A1 New ZONE #3
Run Initiation Time: 05/03/06 07:23:18 Run Code: 1146666198
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: S of 39
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Bellows Residence 5/3/2006
Project Title Date
FENESTRATION SURFACES
# Type Area U-Factorl SHGC2
True
Azm. Tilt
Cond.
Stat. Glazing Type
Location/
Comments
2-Q
Window
Right
(NE)
10.5 0.330NFRC _-o_3.6 NFRC 25
-90_ New Loewen Picture
ZONE #1
21
Window
Right
(NE)
5.0 0.340 NFRC 0.28 NFRC
25
90 New
Loewen CA1
ZONE #1
22
Window
Front
(SE)
54.0 0.350 NFRC 0.20 NFRC
115
90 New
Loewen French Door
ZONE #2
23
Window
Front
(SE)
12.7 0.350 NFRC 0636 NFRC
115
90 New
Loewen Transom
ZONE #2
24
Window
Front
(SE)
54.0 0.350 NFRC 0.20 NFRC
115
90 New
Loewen French Door
ZONE #2
25
Window
Front
(SE)
12.7 0.350 NFRC 0_36 NFRC
115
90 New
Loewen Transom
ZONE #2
26
Window
Front
(SE)
54.0 0.350 NFRC 0_20 NFRC
115
90 New
Loewen French Door
ZONE #2
27
Window
Front
(SE)
12.7 0.350 NFRC 0.36 NFRC
115
90 New
Loewen Transom
ZONE #2
28
Window
Left
OM
24.0 0.340 NFRC 0.28 NFRC
250
90 New
Loewen CA2
ZONE #2
29-
Window
Left
(W)
7.5 0.350 NFRC 036 NFRC
250
90 New
Loewen Arched Transom
ZONE #2
30
Window
Rear
(NW)
24.0 0.340 NFRC 0_28 NFRC
295
90 New
Loewen CA2
ZONE #2
31
Window
Rear
(NW)
7.5 0.350 NFRC 0_36 NFRC
295
90 New
Loewen Arched Transom
ZONE #2
� U
Window
Rear
(NW)
12.7 0.350 NFRC 0_36 NFRC 295
90 New Loewen Transom
ZONE #2
33
Window
Rear
(NW)
12.7 0.350 NFRC 0_36 NFRC
295
90 New
Loewen Transom
ZONE #2
34
Window
Rear
(NW)
54.0 0.350 NFRC 0.20 NFRC
295
90 New
Loewen French Door
ZONE #2
35
Window
Rear
(NW)
54.0 0.350 NFRC 0_20 NFRC
295
90 New
Loewen French Door
ZONE #2
36
Window
Rear
(N)
7.5 0.350 NFRC 0636 NFRC:
340
90 New
Loewen Arched Transom
ZONE #2
37
Window
Rear
(N)
26.0 0.340 NFRC 0.28 NFRC
340
90 New
Loewen CA2
ZONE #2
38
Window
Right
U
48.0 0.350 NFRC 0.20 NFRC
70
90 New
Loewen French Door
ZONE #3
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin Right Fin
# _ Exterior Shade Type SHGC
Hgt. Wd.
Len.
Hgt. LExt.
REA
Dist. Len. Hgt. Dist. Len. Hgt.
20 Bug Screen 0.76
21 Bug Screen 0.76
22 Bug Screen 0.76
23 Bug Screen 0.76
2.0 6.3
8.0
0.1 8.0
8.0
24 Bug Screen 0.76
25 Bug Screen 0.76
2.0 6.3
8.0
0.1 8.0
8.0
26 Bug Screen 0.76
27 Bug Screen 0.76
2.0 6.3
8.0
0.1 8.0
8.0
28 Bug Screen 0.76
29 Bug Screen 0.76
30 Bug Screen 0.76
31 Bug Screen 0.76
32 Bug Screen 0.76
33 Bug Screen 0.76
34 Bug Screen 0.76
35 Bug Screen 0.76
36 Bug Screen 0.76
37 Bug Screen 0.76
38 Bug Screen 0.76
8.0 6.0
9.0
0.1 9.0
9.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat
Inside
Condition Location/
Type (sf) (in.) Cap.
Cond. R -Val.
JA IV Reference
Status Comments
Insulation
Condition Location/
PERIMETER LOSSES
Type Length R -Val.
Location
JA IV Reference
Status Comments
Slab Perimeter 48 None No Insulation
26-A1
New ZDNE #3
Run Initiation Time: 05/03/06 07:23:18 Run Code: 1146666198
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:6 of 39
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
The Bellows Residence 5/3/2006
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments
_3,Q
Window
Right
(E)
30.0 O-3AO NFRC 0_28 NFRC _70 _90_New Loewen CA2
ZONE #3
40
Window
Right
(E)
24.0 0.350 NFRC 0_20 NFRC
70
90 New
Loewen French Door
ZONE #3
41
Window
Right
(E)
24.0 0.350 NFRC 0_20 NFRC
70
90 New
Loewen French Door
ZONE #3
42
Window
Right
(E)
30.0 0.340 NFRC 0.28 NFRC
70
90 New
Loewen CA2
ZONE #3
43
Window
Right
(E)
48.0 0.350 NFRC 0_20 NFRC
70
90 New
Loewen French Door
ZONE #3
- 44
Window
Left
(W)
3.3 0.340 NFRC 0_28 NFRC
250
90 New
Loewen CA1
ZONE #3
A 45
Window
Left
(VV)
3.3 0.340 NFRC 0_28 NFRC
250
90 New
Loewen CA1
ZONE #3
46
Window
Left
()M
3.3 0.340 NFRC 0.28 NFRC
250
90 New
Loewen CA1
ZONE #3
47
Window
Left
(VV)
5.3 0.340 NFRC 0.28 NFRC
250
90 New
Loewen CA1
ZONE #3
A$
Window
Left
(VV)
5.3 0_340 NFRC0 28 NFRC
250
90 New
Loewen CA1
ZONE #3
49
Window
Left
(VV)
3.3 0.340 NFRC 0_28 NFRC
250
90 New
Loewen CA1
ZONE #3
50
Window
Left
tV1r7
3.3 0.340 NFRC 0_28 NFRC
250
90 New
Loewen CA1
ZONE #3
J1
Window
Left
=
3.3 0.340 NFRC 0.28 NFRC 250 90 New Loewen CA1
_ZONE #3
52
Window
Left
(tM
21.8 0.340 NFRC 0_28 NFRC
250
90 New
Loewen CA2
ZONE #3
- 53
Window
Rear
(N)
3.3 0.340 NFRC 0.28 NFRC
340
90 New
Loewen CA1
ZONE #3
54
Window
Right
(E)
41.0 0.350 NFRC 0_20 NFRC
70
90 New
Loewen French Door
ZONE #4
55
Window
Right
(E)
41.0 0.350 NFRC 0_20 NFRC
70
90 New
Loewen French Door
ZONE #4
56
Window
Left
(VV)
7.1 0.340 NFRC 0.28 NFRC
250
90 New
Loewen CA1
ZONE #4
57
Window
Left
(VV)
41.0 0.350 NFRC 0_20 NFRC
250
90 New
Loewen French Door
ZONE #4
1. Indicate source either from
NFRC
or Table 116A. 2. Indicate source either from
NFRC or Table 1168.
0.76
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt.
LExt.
REA Dist. Len. Hgt. Dist. Len. Hgt.
39
Bug Screen
0.76
5.0
6.0
9.0
0.1
9.0
9.0
40
Bug Screen
0.76
8.0
3.0
9.0
0.1
9.0
9.0
41
Bug Screen
0.76
8.0
3.0
9.0
0.1
9.0
9.0
42
Bug Screen
0.76
5.0
6.0
9.0
0.1
9.0
9.0
43
Bug Screen
0.76
8.0
6.0
9.0
0.1
9.0
9.0
44
Bug Screen
0.76
45
Bug Screen
0.76
46
Bug Screen
0.76
47
Bug Screen
0.76
48
Bug Screen
0.76
49
Bug Screen
0.76
50
Bug Screen
0.76
51
Bug Screen
0.76
52
Bug Screen
0.76
53
Bug Screen
0.76
54
Bug Screen
0.76
7.0
6.0
4.0
0.1
4.0
4.0
55
Bug Screen
0.76
7.0
6.0
4.0
0.1
4.0
4.0
56
Bug Screen
0.76
57
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation
Lenath R -Val. Location
JA IV Reference
Condition Location/
Status Comments
Run Initiation Time: 05/03/06 07:23:18 Run Code: 1146666198
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:7 of 39
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
The Bellows Residence
Project Title
5/3/2006
Date
FENESTRATION SURFACES
# Type Area
U-Factorl SHGC2
True
Azm. Tilt
Cond.
Stat. Glazing Type
Location/
Comments
-5$
Window
Rear
(N) 20.5 0.350 NERC 0_20 NERC 340 _$0_ New Loewen French Door
ZONE #4
59
Window
Right
(E) 41.0
0.350 NFRC 0.20 NFRC
70 90 New
Loewen French Door
ZONE #5
60
Window
Right
(E) 41.0
0.350 NFRC 0_20 NFRC
70 90 New
Loewen French Door
ZONE #5
61
Window
Left
(1M 41.0
0.350 NFRC 0.20 NFRC
250 90 New
Loewen French Door
ZONE #5
62
Window
Left
(W) 41.0
0.350 NFRC 0_20 NFRC
250 90 New
Loewen French Door
ZONE #5
63
Window
Rear
(N) 20.5
0.350 NFRC 0_20 NFRC
340 90 New
Loewen French Door
ZONE #5
1. Indicate source either from NFRC or Table 116A.
2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt.
58 Bug Screen 0.76
59 Bug Screen 0.76
60 Bug Screen 0.76
61 Bug Screen 0.76
62 Bug Screen 0.76
63 Bug Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition L)cation/
Type Length R -Val. Location JA IV Reference Status Comments
Run Initiation Time: 05/03/06 07:23:18 Run Code: 1146666198
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:8 of 39
Certificate Of Comaliance : Residential (Part 3 of 4) CF -1 R
The Bellows Residence
Tank
Energy
Duct
Duct Condition
5/3/2006
Location
Project Title
Cooling
Location
R -Value Status
Date
HVAC #1
Ducted
HVAC SYSTEMS
Attic
6.0 New
Yes
HVAC #2
Ducted
Ducted
Attic
Heating
Minimum
Cooling
Minimum
CDndition
Thermostat
Location
Type
Eff
Type
Eff
S-.atus
Type
HVAC #1
Split Heat Pump
8.40 HSPF
Split Heat Pump
14.0 SEER
New
Setback
HVAC #2
Split Heat Pump
8.40 HSPF
Split Heat Pump
14.0 SEER
New
Setback
HVAC #3
Split Heat Pump
8.50 HSPF
Split Heat Pump
15.0 SEER
N Bw
Setback
HVAC DISTRIBUTION
WATER HEATING SYSTEMS Rated l
Tank
Energy
Duct
Duct Condition
Ducts
Location
Heating
Cooling
Location
R -Value Status
Tested?
HVAC #1
Ducted
Ducted
Attic
6.0 New
Yes
HVAC #2
Ducted
Ducted
Attic
6.0 New
Yes
HVAC #3
Ducted
Ducted
Attic
6.0 New
Yes
Hydronic Piping
Pipe Pipe
Insul.
System Name
Length Diameter
Thick.
WATER HEATING SYSTEMS Rated l
Tank
Energy
Standbyl Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Loss R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE 1
(%) Ext.
AWH G62-100T77-4NOV Large Gas No Pipe Insulation 2 77,000
97
New 0.83
2.05% 0.0
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of fie California Code of
Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: Brad Stone
Title/Firm: Stephen Jones Title/Firm: BREEZE AIR CONDITIONING
Address: Po Drawer 4656 Address: 75-145 ST. CHARLES PLACE
Palm De rt CA 9226 PALM DESERT, CA 92211
Telephone: 760 346 66 Telephone: (760) 346-0855
Lic. #: ..
5
(signature)(date) (signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature/stamp) (date)
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Paae:9 of 39 1
Certificate Of CornMiance : Residential (Part 3 of 4) CF -1 R
The Bellows Residence 5/3/2006
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location TvDe Eff TvDe Eff S-:atus TVDe
HVAC #4 Split Heat Pump 8.20 HSPF Split Heat Pump 15.2 SEER New Setback
HVAC #5 Split Heat Pump 8.20 HSPF Split Heat Pump 15.2 SEER N -�w Setback
HVAC DISTRIBUTION
Location
1
HVAC #4 Ducted
HVAC #5 Ducted
Coolin
Ducted
Ducted
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Duct
Location
Attic
Attic
Duct Condition
Ducts
R -Value Status
Tested?
6.0 New
Yes
6.0 New
Yes
WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul.
Water Heater # in Input Cap. Condition Factor Loss • R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or, RE 1 (%) Ext.
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP TvDe In Plenum Outside Buried Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of t -le California Code of
Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, irsulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: Stephen Jones
Address: Po Drawer 456
Teleph
Lic. #:
.-r-
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Documentation Author
Name: . Brad Stone
Title/Firm: BREEZE AIR CONDITIONING
Address: 75-145 ST. CHARLES PLACE
PALM DESERT, CA 92211
Telephone: (760) 346-0855 J/
(signature) (date)
(signature/stamp) (date)
1 EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Paae:10 of 39 1
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
The Bellows Residence 5/3/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The loca. enforcement
agency determines the adequacy of the justification, and may reject a building or design that otherwise complies basad on the
3aequacy or ine special /usimcauon ana aocumentation suomittea.
The Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
Plan I Field
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision cf a CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -ZR Plan Field
installation certificate.
The HVAC System "HVAC #1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documentec on the CF -4R.
The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
The HVAC System "HVAC #2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
The HVAC System "HVAC #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
The HVAC System "HVAC #3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
The HVAC System "HVAC #3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
The HVAC System "HVAC #4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
The HVAC System "HVAC #4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
The HVAC System "HVAC #5" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R.
The HVAC System "HVAC #5" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic =xpansion
Valve.
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Paoe:11 of 39 1
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approacl• used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance speci9cations for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
Instructions: Check or initial applicable boxes when completed or check N/A if not
ENFORCE
DESCRIPTION
DESCRIPTION
N/A
DESIGNER
MENT
Building Envelope Measures
§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
Q
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
❑
Q
❑
b. outside air intake with damper and control, flue damper and control
❑
❑X
❑
2. No continuous burning gas pilot lights allowed.
❑
❑X
❑
§ 150(0: Air retarding wrap installed to comply wit@ 151 meets requirements specified in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and
El
El
11include
CF -6R Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
Q
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
❑
Q
❑
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑x
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑X
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.56 must be externally wrapped with
❑
❑X
❑
insulation having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
Q
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑X
❑
length of recirculating sections of hot water pipes shall be insulated to Table 1508.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source
❑
0
❑
and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment
❑
❑X
❑
maintenance, and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑X
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number:
Page: 12 of 39
Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. Wher this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, E04, ❑ ❑X ❑
605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirement,-
of
equirementsof UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑x ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to causa
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑
❑x
❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑X ❑
4. Exhaust fan systems have back draft or automatic dampers.
❑
❑X
❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operatirg
❑
❑x
❑
dampers.
electric and have an output frequency no less than 20 kHz.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑
❑X
❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
❑ ❑X ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
retardant and provides shielding from solar radiation that can cause degradation of the material.
§ -150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaire.:.
❑ 0 ❑
7. Flexible ducts cannot have porous inner cores.
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
0
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑X ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Tabla
❑ X❑ ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ Q ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑X ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires
§ -150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaire.:.
❑ 0 ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility roomE
shall be high efficacy luminaires (except closets less than 70 ft) OR by dimmer OR
❑ ❑X ❑
are controlled a switch are
controlled by an occupant sensor that complies with Section 919(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑X ❑
certified to ASTM E283 and labeled as airtight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑X ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Artic e
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 115(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Secion
119 (d).
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number:
Page: 13 of 39
Residential Kitchen Lighting Worksheet WS -5R
The Bellows Residence 5/3/2006
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
Luminaire Type
High Efficacy? Watts
Quantity
High Efficacy
Watts Other Watts
60w Incandescent
Yes No X 60.0
x
3 =
or 180
Halo H800E CFL
Yes X1 No 1 34.0
x
10 =
340 or
Low Voltage Strip Lighting 15W/ft
Yes No X 15.0
x
10 =
or 150
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Yes No
x
=
or
Total A:
340 B: 330
COMPLIES IF A,?- B YES ® NO ❑
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 14 of 39 1
[HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Bellows Residence 5/3/2006
SYSTEM NAME FLOOR AREA
HVAC #1 1,276
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
1,263
24,709
3,01
1,857
25,624
0
1,985
1,483
0
0
96
3,875
2,174
96
4,410
0
0
1,985
1,483
32,5755F777;:;85 1 33,00
MAYTAG PSH4BF / PAH4VM (5 Ton) 46,969 0 34,976
Total Adjusted System Output 46,969 0 3x,976
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 67.2 of 83.7 of 83.7 of
O Supply Air Ducts
Outside Air
96 cfm 83.0 of
Heating Coil Supply Fan
2000 cfm ROOMS
70.0 of
69.3 of
111.0 / 77.6 of
Outside Air
96 cfm
72.9 / 60.0 of
f% Return Air Ducts `{
74.8/61.10F 0 52.7/51.60F
Cooling Coil
Supply Fan
2000 cfm
52.7 / 51.6 of
Supply Air Ducts
53.6 / 52.0 of
48.7% R.H. ROOMS
72.0 / 59.7 of
K Return Air Ducts `S
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Paae:15 of 39 1
[HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Bellows Residence 5/3/2006
SYSTEM NAME FLOOR AREA
HVAC #2 1,513
126.0 of
Outside Air
113 cfm
69.4 of
66.9 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
Sensible
LatYnt
I I CFM
I Sensible
1,152
22,448
1496
1104
23,064
0
1,804
1,335
0
0
113
4,605
2,522
113
5,238
0
0
1,804
1,335
30,660 6,018 1 30,972
HVAC EQUIPMENT SELECTION
MAYTAG PSH4BF / PAH4VM (5 Ton) 47,195 0 34,976
Total Adjusted System Output x7,195 0l 3x,976
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Heating Coil
83.3 of
83.3 of
O Supply Air Ducts
Supply Fan 82.7 of
2000 cfm ROOMS
70.0 of
Return Air Ducts I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.6OF 75.0/61.4OF 52.8/51.8OF 52.8/51.8OF
O Supply Air Ducts
Outside Air
113 cfm Cooling Coil Supply Fan 53.7 / 52.1 of
2000 cfm 45.3% R.H. ROOMS
72.8/60.1 of 72.0 159.8 of
h Return Air Ducts '�
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page: 16 of 39 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Bellows Residence 5/3/2006
SYSTEM NAME FLOOR AREA
HVAC #3 1,143
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
I CFM
I Sensible
87
17,694
3,339
1,416
20,389
0
1,422
1,180
0
0
86
3,480
1,957
86
3,95
0
0
1,422
1,180
24,018 5,296 26,700
HVAC EQUIPMENT SELECTION
MAYTAG PSH4BF / PAH4VM (4 Ton) 38,613 0 29,355
Total Adjusted System Output 38,613 0 29,355
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aig 2 pm Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 OF 67.0 OF 84.2 OF 84.2 OF
OSupply Air Ducts
Outside Air
86 cfm o
Heating Coil Supply Fan 83.5 F
1600 cfm ROOMS
70.0 OF
69.3 OF
>% Return Air Ducts `S
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temneratures at Time of Coolina Peak) I
111.0 / 77.6 OF
Outside Air
86 cfm
72.8/59.9 °F
74.9/61.1°F 52.2/51.1°F 52.2/51.1°F
S I A' D
Cooling Coil
O upp y Ir ucts
Supply Fan 53.0 / 51.5 OF
1600 cfm 43.6% R.H. ROOMS
72.0 59.6 OF
Return Air Ducts I
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Paoe:17 of 39 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Bellows Residence 5/3/2006
SYSTEM NAME FLOOR AREA
HVAC #4 387
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
25,000
Total Output (Btuh)
25,000
Output (Btuh/sqft)
64.6
Cooling System
Output per System
24,000
Total Output (Btuh)
24,000
Total Output (Tons)
2.0
Total Output (Btuh/sqft)
62.0
Total Output (sgft/Ton)
193.5
Air System
CFM per System
800
Airflow (cfm)
800
Airflow (cfm/sgft)
2.07
Airflow (cfm/Ton)
400.0
Outside Air (%)
3.6
Outside Air (cfm/sqft)
0.07
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS
26.0 of 68.0 of
Outside Air
29 cfm
69.6 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
I CFM
I Sensible
403
8,662
1,192
384
6,496
0
696
376
0
0
29
1,179
734
29
1,345
0
0
696
376
11,233 1,926 8,593
MAYTAG PSH46F / PAH4VM (2 Ton) 19,786 0 15,614
Total Adjusted System Output 19 786 0 15,614
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK At g 2 pm Jan 12 am
Heating Coil
3m Tem
86.3 of
at Time of
86.3 of
O Supply Air Ducts
Supply Fan 85.9 of
800 cfm ROOMS
70.0 of
Return Air Ducts '
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I
111.0/77.6OF 74.2/60.OoF . 51.0/49.80F 51.0/49.8OF
Outside Air
29 cfm
Cooling Coil
72.8/59.1 of
O Suoply Air Ducts
Supply Fan 51.8 / 50.2 of
800 cfm 45.6% R.H. ROOMS
72.0 / 58.8 of
Return Air Ducts
EnergyPro 4.1 by EnergySoft User Number: 3665 Job Number: Page:18 of 39 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Bellows Residence 5/3/2006
SYSTEM NAME FLOOR AREA
HVAC #5 429
NEERIN
Number of Systems
1
Heating System
Output per System
25,000
Total Output (Btuh)
25,000
Output (Btuh/sqft)
58.3
Cooling System
Output per System
24,000
Total Output (Btuh)
24,000
Total Output (Tons)
2.0
Total Output (Btuh/sgft)
1 55.9
Total Output (sgft/Ton)
214.5
Air System
CFM per System
800
Airflow (cfm)
800
Airflow (cfm/sgft)
1.86
Airflow (cfm/Ton)
400.0
Outside Air (%)
4.0
Outside Air (cfm/sgft)
0.07
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
1, CFM
I Sensible
459
9,753
1,278
427
7,103
0
784
41
0
0
32
1,303
803
32
1,490
0
0
784
411
12,623 2,08
HVAC EQUIPMENT SELECTION
MAYTAG PSH413F / PAH4VM (2 Ton) 19,857 0
Total Adjusted System Output 19 857 0
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm
EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak)
26.0 of
Outside Air
32 cfm
69.5 of
67.8 OF ■ 86.1 OF
Heating Coil
�1
Supply Fan
800 cfm
9,415
15,614
15,614
Jan 12 am
86.1 of
Sup01y Air Ducts
85.6 of
ROOMS
70.0 of
1% Return Air Ducts 11
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I
11.0/77.6 of 74.5/60.2 of
Outside Air
32 cfm
72.9/59.3 of
51.1 / 50.0 of 51.1 / 50.0 of
O Supply Air Ducts
Supply Fan 52.0 / 50.4 of
800 cfm 46.C -7o R.H. ROOMS
72.0 ! 58.9 of
Return Air Ducts I
Cooling Coil