Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-6382 (SFD)
il -J� 7 Inn; ul�cv I BUILDING & SAFETY DEPARTMENT CI7"," O°' LC °"� Roy S - �I�,v r P O.> B°OX 1504 FINARCE Dv?W'T. (760).777-7012 'OF9 78-495 CALLS TA PICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . . . . . X04=0000-6382 Date 1/27/05 Property Address . . . . . . 80550 VIA PESSARO APN: 772-500-017- - - Application description DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . LOW DENSITY RESIDENTIAL Application valuation 384775 Owner Contractor ------------------------ MR TIM WHITE ------------------------ RAM DEVELOPMENT P 0 BOX 6045 75161 SEGO LANE, SUITE F-3 OXNARD CA 93030 PALM DESERT CA 92261 WCC: STATE FUND WC: 0460009059 01/01/OE CSLB: 529976 05/31/OE CCC: B ------ Structure Information 4423 SQ. FT SFD ----- Construction.Type . . . TYPE V - NON RATED Occupancy -Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1049.00 PATIO SQ FTG 514.00 NUMBER OF UNITS .1.00 IST FLOOR SQUARE FOOTAGE 3850.00 2ND FLOOR SQUARE FOOTAGE 573.00 ---------------------------------------------------------------------------- Permit . . . BUILDING PERMIT Additional desc Permit Fee . . . . 1637.00 Plan Check Fee 1064.05 Issue Date . . . . Valuation 384775 Expiration Date 7/27/05 Qty Unit Charge Per • Extension BASE FEE 639.50 285.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 997.50 Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 205.79 Plan Check Fee 51.45 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/27/05 Qty Unit Charge Per Extension BASE FEE 15.00 f P.O. Box 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: t' �—(63 0 Applicant: Applicant's Mailing Address: Date: t ^ e % Architect or Engineer: Architect or Engineer's Address: Lic. No.: t3UILVING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed ynder provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals /Code, and myLicense�is in full force and effect. License Class_ 41cense No. S— ZQ z/ Date 1-277—os— ✓ Contractor ✓:= . OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owne WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My Corkers' c ensation insurance cartiepand policy number are: CarrieSi�Y� `t= J N Policy Numbert_/ 64 (o 0 O O el"1 C) —(* _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ✓ Date �'2� —OS' " Applicant_ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date (�2� �� Signature (Applicant or Agent)J Page 2 Application Number . . . . . 04-00006382 Date 1/27/05 Qty Unit Charge Per Extension 4423.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 154.81 1049.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 20.98 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 ---------------------------------------------------------------------------- Permit GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/27/05 Qty Unit Charge Per Extension BASE FEE 15.00 ----------------------------------------------------------------------------- Permit MECHANICAL Additional desc . . Permit Fee . . . . 145.50 Plan Check Fee 36.38 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/27/05 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 8.00 6.5000 EA MECH VENT FAN 52.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit PLUMBING Additional desc Permit Fee . . . . 297.00 Plan Check Fee 74.25 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/27/05 Qty Unit Charge Per Extension BASE FEE 15.00 30.00 6.0000 EA PLB FIXTURE 180.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 6.00 6.0000 EA PLB ROOF DRAIN 36.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 12.00 .7500 EA PLB GAS PIPE >=5 9.00 1.00 ------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Special Notes --------------------------- and Comments 4423 SQ. FT. SFD THIS PERMIT DOES NOT Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 2300.29 Page 3 Application Number . . . . . 04-00006382 Date 1/27/05 -----------------------------------7---------------------------------------- Special Notes and Comments INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH. 10/22/04 8:58:46 AM jjohnson ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 461.93 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 106.41 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 38.47 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 2300.29 .00 1226.13 500.00 3011.81 .00 6538.23 500.00 Credited Due .00 2300.29 .00 726.13 .00 3011.81 .00 6038.23 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 7) CF4R Firm: Street Address: 41r— Copies 1 —Copies to: Builder, HERS Provider Plan Number Sample Group Number Sample House I` -um er HERS Provider: City/State/Zip: HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested ❑ Approved aspart of sample testing, but was not tester. As the HERS rater providing diagnostic testing and field verification? I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used;in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ' ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Duct Pressurization Test Results (CFM @ 25 Pa) Test Leakage Flow in CFM If fan flow is calculated as 400cfin/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Measured values Qhe_Gk Box for- Pass or Fail (Pass=656 v, less) 13 [3 Pass Fail 1 THERMOSTATIC EXPANSION VALVE (TXV) Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ Yes is a pass Tals Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1. ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -1R and design on plan. 2. ❑ Yes ❑ No TXV is installed or.Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. i } Measured Fan Flow = ❑ ❑ Yes for both -.1 and 2 is a Pass Pass Fail Compliance Forms August 2001 , A-16 Project Title Date Project dress Builder Name Firm: Street Address: 41r— Copies 1 —Copies to: Builder, HERS Provider Plan Number Sample Group Number Sample House I` -um er HERS Provider: City/State/Zip: HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested ❑ Approved aspart of sample testing, but was not tester. As the HERS rater providing diagnostic testing and field verification? I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used;in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ' ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Duct Pressurization Test Results (CFM @ 25 Pa) Test Leakage Flow in CFM If fan flow is calculated as 400cfin/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Measured values Qhe_Gk Box for- Pass or Fail (Pass=656 v, less) 13 [3 Pass Fail 1 THERMOSTATIC EXPANSION VALVE (TXV) Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ Yes is a pass Tals Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1. ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -1R and design on plan. 2. ❑ Yes ❑ No TXV is installed or.Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. i } Measured Fan Flow = ❑ ❑ Yes for both -.1 and 2 is a Pass Pass Fail Compliance Forms August 2001 , A-16 Building Address 55—d Mailing 1 G ` 4P5 Address .�. 6�0 �Cr/ LSJC.� P.O. BOX 1504 78-495 CALLE TAMPICO OUINTA. CALIFORNIA 92253 ty Z'� !/ Te� & Classif. (p '� `�(p t) Lic. #(,2 Arch., Engr., ct ^ --� Designer �J F1191611i ��<tA 1. , i a LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds ori mproves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. It, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT T c�>D Lr2'- 3 g Z APPLICATION ONLY BUILDING: TYPE CONST \/ ^ 74 OCC. P. .GGR�' .. A.P. Number 7171c5boy l - Legal Description Project Description ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback fron Rear Prop. Line Side Street Setback from Center Line Side Setback fron Property Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit YELLOW = APPLICANT PINK = FINNNCE Sq. Ft. 3g�5No. �^ Size Stories No. Dw. l Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. 0 Plan Chk. Bal. ZO Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure 1 TOTAL ` — �- REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback fron Rear Prop. Line Side Street Setback from Center Line Side Setback fron Property Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit YELLOW = APPLICANT PINK = FINNNCE Date 1/27/05 No. 26824 Owner Address City Tract # Type White Zip Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units BERMUDA DUNES r U= RANCHO MIRAGE r INDIAN WELLS PALM DESERT y LA QUINTA 11�1OINDIO yr 772-500-0017 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 80550 Via Pessaro 4423 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 4,423 S.F. or $9,907.52 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Provident - Sue Codekas Name on the check By Dr. Doris Wilson Superintendent Fee collected McGilvr6y Check No. 135132 Telephone 568-9335 Funding Residential Payment Recd $9,907.52 Over/Under Signature i NOTICE: Pursuant to Government a Section (d)(1), this 'll to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from a date on � the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity a to collect them on the District(s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy - Accounting , , Certificate of Occupancy0 o - T •MaAt ot Lrwtrow7En4�� OF g Y p Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-550 VIA PESSARO Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-6382 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: TIM WHITE Address: P.O. BOX 6045 City, ST, ZIP: OXNARD CA 93030 By: STEVE WILLETT !�ZA� Date: APRIL 24, 2006 Building Official POST IN A CONSPICUOUS PLACE k o 0 • • 0 • 0 • • I TITLE 24 REPORT ' I -Title 24 Report for: W H I T E Guest House 80-6�IOVia Pessaro La Quinta, C Project Designer: McFadden/McIntosh Architects 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 Report Prepared By: Micah Combs C.M. Energy Consulting 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 Job Number:., 0316.00 i Date: i a 8/10/04 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 0316.00 User Number. 1086 W556h*416 of(tt& torr �� Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. Wher this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures t whether they are shown elsewhere in the documents or on this checklist only. • 0 U C] 0 0 0 DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ® '§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value. ®§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ®§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. a§ 150(e): Installation Fireplaces, of Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures [?q § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. E] §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE. SMACNA or ACCA. ®§150(i): Setback thennostat on all applicable heating and/or cooling systems. ® §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 PageA of 2 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into (� the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures 1 1 whether they are shown elsewhere in the documents or on this checklist only. ul 0 0 46 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ®'§ 150(m): Ducts and Fans I 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirety in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36' of pipe between fitter and heater for future solar, cover for outdoor pools or spas. i a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ® §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for §150(k)l: 9 9 9� P c1/ i i general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ® §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:2 of2 11 0 IN d od �J • Certificate of Compliance: Residential p (Part 1 of 2) CF -1 R W H I T E Guest House 8/10/04 j Project Title Date 80-5, Vla Pessaro La Qulnta •TFr-o—je-cTAddress C.M. Energy Consulting (760) 346-8014 Documentation AUthor a ep one Computer Performance 15 C I' 0 0 0 0 • Building ermi Plan Check Date Held GhEckDate omp lance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 618 ft2 Total Conditioned Slab Area: 618f? Average Ceiling Height: 9.6 ft Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Southwest) 225 deg Floor Construction Type: 0 Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Component Type Frame Type Assembly U -Value Location/CommentE (attic, garage, typical, etc.) C/11-2 (R.38.2x_.16) Wood 0.026 Exterior Roof W-1 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall W-2 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Slab On Grade n1a 0.756 Exposed Slab w/11-0.0 Perimeter Insulation Slab On Grade Na 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Ahnrlinn llav?raa Type Orientation Area Fenestration Exterior v Cverhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Left (Northwest) 18.0 0.72 0.77 Bug ScreenX❑ ❑ ❑ a Left (Northwest) 24.0 0.51 0.40 Bug Screen o ❑ ❑ a Rear (Northeast) 4.5 0.51 0.53 Bug Screen X❑ ❑ ❑ Q Rear (Northeast) 4.5 0.67 0.60 Bug ScreenX❑ ❑ ❑ IN Rear (Northeast) 64.0 0.49 0.44 Bug ScreenX❑ ❑ ❑ 0 Front (Southwest) 18.0 0.72 0.77 Bug Screen X❑ 1:1 El Front (Southwest) 64.0 0.49 0.44 Bug Screen K ❑ ❑ 0 ❑❑ El F] 10 1:1 El 1:1 El ❑❑ 11 1:1 El 1:1 El El El El Run Initiation Time: 08/10/04 16:24:05 Run Code: 1092180245 EnergyPro 3.1 By EnergySoft . User Number. 1086 Job Number. 0316.00 Page:1 of 3 0 0 • 1 This certificate of compliance lists the building features and performance specifications needed to comply with Tile 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Micah Combs Title/Firm: McFadden/McIntosh Architects Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Address: 72-925 Fred Waring Drive Suite 204 Palm Desert, CA 92260 Palm Desert, CA 92260 Telephone: (760) 346-8014 Ti Lic. #: (signatu a (date) Enforce a Agency Name: Title/Firm: Address: Telephone: signature stamp ate Run Initiation Time: 08/10/0416:24:05 Run Code: 1092180245 EnergyPro 3.1 By EnergySoft ' User Number. 1086 Job Number. 0316.00 Page:2 of 3 k Certificate of Compliance: Residential p (Part 2 of 2) CF -1R W H I T E Guest House i-rojeCt Title 8/10/04 Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat LocEtion / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 1 (Guest House) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Locc-lion / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE •1 (Guest House) WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery- Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value CONTINUUM RINNAI Instant Gas Point of Use 1 199,000 0 0.82 0 n/a } 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS 0 0 • 1 This certificate of compliance lists the building features and performance specifications needed to comply with Tile 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Micah Combs Title/Firm: McFadden/McIntosh Architects Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Address: 72-925 Fred Waring Drive Suite 204 Palm Desert, CA 92260 Palm Desert, CA 92260 Telephone: (760) 346-8014 Ti Lic. #: (signatu a (date) Enforce a Agency Name: Title/Firm: Address: Telephone: signature stamp ate Run Initiation Time: 08/10/0416:24:05 Run Code: 1092180245 EnergyPro 3.1 By EnergySoft ' User Number. 1086 Job Number. 0316.00 Page:2 of 3 k 41 0 0 r 11 0 Certificate of Compliance: Residential (Addendum) CF -1 R H I T E Guest House 8/10/04 Date zpeclal i-eatures and Modeling ASSumptions The local enforcement agency should pay special attention to the items specified in this checklist. These item s require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies haaarl nn fha edan..�r•...f fha ..1 1...6.41....6:.......-J d......- ------....._ ......-1 i v. -..e .a 11 - 4u.vaa.v.. a.— uV•.Y...vii auull SU rilitteu. Plan Field The HVAC System "ZONE 1 (Guest House)" includes credit for a Radiant Barrier installed per Section 8.13 of t -ie Residential Manual HIGH MASS Design(see C-211) - Verify Thermal Mass: 204 sgft Tile in Mortar Interior Mass, 0.75" thick at Guest House HIGH MASS Design(see C-211) - Verify Thermal Mass: 204 sgft Exposed Slab Floor, 4.00" thick at Guest House HIGH MASS Design(see C-211) - Verify Thermal Mass: 414 sgft Covered Slab Floor, 4.00" thick at Guest House - HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document tha field varifie-atinn nn.t Ainnnnafin f-6;— .•f fhe� . r--_ n, — • - - - ----- ---------------- ---- •--•- --. ... �.. _......v .....a..vv..v .estina of u.vae ... easum VII a IVI111 Vr'VR • an eld e ys em (Guest House)- nc u es a lgeran Charge an l ow rel ora ce rie rater rovide verification of the TXV, or measure the Refrigerant Charge and Airflow. mus I Run Initiation Time: un Code: 1092180245 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:3 of 3 0 C � o0 c • C 0 Computer Method Summary (Part 1 of 3) C -2R W H I T E Guest House 8/10/04 ro e e -Date -30-566 Via Pessaro La Quinta Source Energy Use Standard Proposed Compliance Project Address "JuildinEPer—mW;; • C.M. Energy Consulting (760) 346-8014 -Documentation • u or Te ep one P an 3c a e Computer Performance 15 Compliance Method (Package or Computer) Cute ons Fieldec a e 0 Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin • Space Heating 2.76 2.95 -0.19 Space Cooling 50.02 65.50 -15.48 Domestic Hot Water 31.34 13.43 17.91 Totals 84.12— 81.88 --2—.24— Percent better than Standard: 2.7% • Total Conditioned Floor Area: 618 ft2 Floor Construction Type: ❑ Raised Floor ® Slab Floor Building Type: Single Fam Detached Building Front Orientation: (Southwest) 225 deg Total Fenestration Area: 31.9% Number of Dwelling Units: 1.00 Total Conditioned Volume: 5,933 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 618 ft 2 • BUILDING ZONE INFORMATION Zone Name # of Thermostat Floor Area Volume Units Zone Type Type Vent Hgt. Area ZONE 1 (Guest House) 618 5.933 1.00 Conditioned Setback 2 Na moa OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Locaion / Comments Roof 643 0.026 0 0 ❑ C/11-2 (R.38.2x_.16) ZONE 1 ONLY Wall 170 0.057 330 90 ❑ W-1 Wall (W.21.2x6.16) ZONE 1 ONLY Wall 116 0.057 60 90 W-1 Wall (W.21.2x6.16) ZONE 1 ONLY Wall 36 0.057 60 90 ❑ W-2 Wall (W.21.2x6.16) ZONE 1 ONLY Wall 179 0.057 150 90 W-2 Wall (W.21.2x6.16) ZONE 1 ONLY Wall 136 0.057 240 90 ❑ W-1 Wall (W.21.2x6.16) ZONE 1 ONLY ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ F ❑ ❑❑ ❑❑ F-1 F-1 F-1 F1 1-1 F-1 • ❑❑❑❑ ❑❑ F-1 F-1 ❑a Run Initiation Time: 08/10/0416:24:05 Run Code: 1092180245 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number: 0316.00 Page:1 of 4 0 40 Computer Method Summary (earl 2 of 3) C -2R W H I T E Guest House 8/10/04 ( •roe i e Date 1� U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window Left (Northwest) 18.0 0.720 0.77 330 90 Glass Block Default (R) ZONE 1 ONLY 2 Window Left (Northwest) 24.0 0.510 0.40 330 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 3 Window Rear (Northeast) 4.5 0.510 0.53 60 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 4 Window Rear (Northeast) 4.5 0.670 0.60 60 90 Double Tinted Default (NW) ZONE 1 ONLY 6 Window Rear (Northeast) 64.0 0.490 0.44 60 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY • 6 Window Front (Southwest) 18.0 0.720 0.77 240 90 Glass Block Default (R) ZONE 1 ONLY 7 Window Front (Southwest) 64.0 0.490 0.44 240 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY INTERIOR AND EXTERIOR SHADING # Window Overhang Left Fin Right Fin Exterior Shade Type SHGCg�Wa Len. Hgt. xt. xt. Dist. Len. R gt. Dist. Len. gt. Bug Screen 0.76 0. 0.0 0.0 0.0 2 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 5 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 7 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Run Initiation Time: 08/10/0416:24:05 Run Code: 1092180245 EnergyPro 3.1 By EnergySoft User Number: 1086 Job Number. 0316.00 Pagel of 4 40 Run Initiation Time: 08/10/04 16:24:05 Run Code: 1092180245 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number: 0316.00 Page:3 of 4 • Computer Method Summary (Part 3 of 3) C-2R W H I T E Guest House 8/10/04 ro ec e a e THERMAL MASS FOR HIGH MASS DESIGN • Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R-Val. Comments Tile in Mortar 204 0_75 24 0_67 n/a 0 ZONE 1 ONLY / Interior Mass Concrete, Heavyweight 204 4.00 28 0.98 n/a 0 ZONE 1 ONLY / Slab on Grade Concrete, Heavyweight 414 4.00 28 0.98 n/a 2 ZONE 1 ONLY / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R-Val. Depth Location / Comments Slab Perimeter 5 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 71 0.76 0.0 0 ZONE 1 ONLY HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat LocaLon / • pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R-Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 1 (Guest House) 4( Jiydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat LocaWn / • heat pump, evap. cooling) (SEER) (attic, etc,) R-Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 1 (Guest House) • WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R-Value System Name Type Type Syst. (Btu/hr). (gal) Efficiency Loss (%) Ext. CONTINUUM RINNAI V2532W Instant Gas Point of Use 1 199,000 0 0.82 0 n/a • 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy actor. For large gas storage water heaters (rated Input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS � r Run Initiation Time: 08/10/04 16:24:05 Run Code: 1092180245 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number: 0316.00 Page:3 of 4 • 0 0 0 0 0 F, Computer Method Summary (Addendum) C -2R H I T E Guest House 8/10/04 Date The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies k nA r.n 4k .sae. wi 61.w wl 1 ...:Cw .J J_ •• • , • • •• .•. ..... ya ....Y . FUu— juaaulleaa—ii anu u0cuulenlauvu suuanueu. Plan Field The HVAC System 'ZONE 1 (Guest House)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual HIGH MASS Design(see C-211) - Verify Thermal Mass: 204 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest House HIGH MASS Design(see C-211) - Verify Thermal Mass: 204 sgft Exposed Slab Floor, 4.00" thick at Guest House HIGH MASS Design(see C-211) - Verify Thermal Mass: 414 sgft Covered Slab Floor, 4.00" thick at Guest House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must rincument thn fialA vari£rntinn —A ri-n—fiia rn��:.... s K.w�., ... _ c_ -w. n1 — ..........v......v .....a..v.aa.v ay.aa...to v. a.ese imasules VII a 1-1111 \rr-WR. an le ld e HVAG System(Guest ouse includes Keffigerant Charge and AirHow Cred ra ce i e ra rovide verification of the TXV, or measure the Refrigerant Charge and Airflow. r mus I -- un InitiationTime: un Code: 1092180245 1 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:4 of 4 i , s • no _d . d O • 0 C 17, 0 0 • 0 • Ll PROPOSED CONSTRUCTION ASSEMBLY ENV -3 W H I T E Guest House 1 8/10/04 SUBTOTAI R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 ASSEMBLY NAME C/R-2 (R.38.2x_.16) Air Space 5 ASSEMBLY Floor Gypsum or Plaster Board 7 TYPE (check one) Wall MIS G W Ceiling / Roof INSIDE SURFACE AIR FILM H a FRAMING MATERIAL yy Z FRAMING % 10 %o Framing /o 15% (16" o.c. Wall) 1 4,3 TOTAL HC 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 0.39 E98 MIS 1.39 2.60 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ ❑ ® ❑ El El El 0.170 0.250 0.010 0.625 2.000 1.500 0.625 0.800 11.880 38.000 11.385 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.210 0.210 0.060 0.060 0.775 0.775 0.800 11.880 38.000 11.385 0.562 0.562 0.39 1.36 MIS 0.36 1.39 2.60 0.610 0.610 41.19 25.65 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 2M 0.24 0.60 O.C6 0.35 0.02 1.77 0.29 0.51 3.491 0.39 1.36 MIS 0.36 1.39 2.60 0.26 0.68 1 4,3 TOTAL HC 4.6 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0243 X 0.90] + [ 0.0390 X 0.10 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number: 0316.00 Page:1 of 3 0 • rm 41 0 is 0 Fj 0 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 W H I T E Guest House 8/10/04 SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 ASSEMBLY NAME W-1 Wall (W.21.2x6.16) Insulation, Mineral Fiber, R-21 5 ASSEMBLY Floor 0.31 7 TYPE (check one) Wall 2.60 LU a W Ceiling / Roof INSIDE SURFACE AIR FILM H 13 FRAMING MATERIAL yy p z FRAMING % 15 %a Framing /o 15% (16" o.c. Wall) 14.8 TOTAL HC 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 6 2.60 9 0.68 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ ❑ ❑ El El 0.170 0.875 0.010 0.375 5.500 0.625 0.465 21.000 5.445 0.5621 0.562 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.5621 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.680 0.680 23.11 7.56 *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 1 / Rc 1 - (Fr% /100) 8.461 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.8 TOTAL HC 3.7 .\4r fel 'NOTE: Weight and Specific Heat values for materials penetrated by wood framina include the effects of the framinn momhom [ 0.0433 X 0.85 ] + L 0.1323 X L0.15 1 / Rc 1 - (Fr% /100) 1 / Rf Fr° /0 / 100 ASSEMBLY U VALUE EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Pagel of 3 0 0 EM 0 0 0 0 • 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 W H I T E Guest House I 8/10/04 J SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 3 ASSEMBLY NAME W-2 Wall (W.21.2x6.16) 0.37 5 ASSEMBLY Floor 0.68 7 TYPE (check one) Wall LU G W Ceiling / Roof INSIDE SURFACE AIR FILM H FRAMING MATERIAL yy p FRAMING % 15 %o Framing /o 15% (16" o.c. Wall) TOTAL HC 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.37 5 2.60 6 0.68 7 8 9 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) FRAMING ❑ [XJ ❑ El El El El 0.170 0.625 5.500 0.625 5.445 0.562 0.562 0.37 0.98 2.60 0.26 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.562 0.562 21.000 5.445 0.562 0.562 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 L. 22.98 7.42 *HEAT CAPACITY (Optional) WALL WEIGH- (Ibs/sQ SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) = 0.057 1 / Rc 1 - (Fr% / 100) 2.60 0.26 0.68 2.63 0.37 0.98 2.60 0.26 0.68 TOTAL HC 2.3 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing mpmhprc [ 0.0435 X 0.85 +[ 0.1348 X 0.15 ] = 0.057 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr*'-/ 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0316.00 Page:3 of 3 uh( I TITLE 24 REPORT VI Title 24 Report for: W H I T E Main House 80-5(ED Via Pessaro La Quinta, CA 92253 Project Designer: McFadden/McIntosh Architects 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 Report Prepared By: Micah Combs C.M. Energy Consulting 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 (760) 346-8014 Job Number: 0418.00 LF09 � ;= I r% .Y. -�Date:8/10/04 )The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. 0418.00 User Number. 1086 �o-sso ,O ,tet- ' 1 DIA WIM ,O ,tet- ' 1 A .0 .. d � b 4� lel .0 • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R G 0 0 0 .r 0 0 0 NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approEch used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable DESIGNER ENFORCEMENT Building Envelope Measures ® '§150(.): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. ®'§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). E] ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no ❑§ greater than 2.0 perm/inch. ®§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. © 150(e): Installation Fireplaces, § of Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ®§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ® §150(j): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:1 of 2 w Mandatory Measures Checklist: Residential (Page 2 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated Into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 40 40 0 0 00 0 0 0 0 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ®'§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely In conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive duct tapes unless such tape is used In combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed In cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. [X] U § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36' of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ®§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ® §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 1086 Job Number: 0418.00 Page: 2 of 2 0 0 0 49W 0 0 0 0 Ll 0 n v 0 • F, 0 0 0 Certificate of Compliance: Residential (Part 1 Of 2) CF -1 R W H I T E Main House 8/10/04 rojec e -D-aTe- Building mlermit Plan e• -.k I Da e Field ec a e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION 80-51 , via Pessaro La Quetta rF o�ect Address C.M. Energy Consulting (760) 346-8014 ocumen a ion Author a ep one Computer Performance 15 Total Conditioned Floor Area: 3,805 ft2 Average Ceiling Height: 10.2 ft Total Conditioned Slab Area: 3,232 ft2 Building Type: (check one or more) ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 2 ❑ Raised Floor BUILDING SHELL INSULATION Component Type Frame Type Assembly U -Value Location/Comments (attic, garage, typical, etc.) C/11-2 (R.38.2x .16) Wood 0.026 Exterior Roof C/11-3 (R.38.2x_.16) Wood 0.030 Exterior Roof W-1 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall W-2 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door Slab On Grade Na 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade Na 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shadina Deices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Skylight 3.7 0.68 0.55 None❑ X❑ ❑ X❑ Rear (Northwest) 138.0 0.51 0.53 Bug Screen X❑ ❑ ❑ x❑ Rear (Northwest) 260.0 0.51 0.40 Bug Screen x❑ ❑ ❑ a Right (Northeast) 101.0 0.51 0.53 Bug Screen X❑ ❑ ❑ X❑ Front (Southeast) 45.0 0.96 0.53 Bug Screen ❑X ❑ ❑ X❑ Front (Southeast) 76.0 0.51 0.53 Bug Screen ❑X ❑ ❑X❑ Left (Southwest) 86.7 0.51 0.53 Bug Screen X❑ ❑ ❑ X❑ Left (Southwest) 20.0 0.51 0.40 Bug Screen ] El 1:1 NFront (Southeast) 48.0 0.51 0.40 Bug Screen ® ❑ ❑ Right (Northeast) 12.5 0.77 0.59 Bug Screen ❑X 1:1 El ❑X Right (Northeast) 12.5 0.49 0.46 Bug Screen ❑X ❑ ❑ x❑ ❑❑ ❑❑ Run Initiation Time: 08/10/04 16:24:57 Run Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0418.00 Page:1 of 3 0 9 0 l This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: McFadden/McIntosh Architects Address:. 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 Telephone: (760) 346-8014 Lic. (sig aur r (date) Enfo a nt Agen Name: Title/Firm: Address: Telephone: Name: Micah Combs Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 Telephone: (760)4.46-89W .0 Q-() j (signatur) (date) dat �) (signature/stamp) date Run Initiation Time: 08/10/04 16:24:57 Run Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:2 of 3 Certificate of Compliance: Residential p (Part 2 of 2) CF -1 R W H I T E Main House 8/10/04 rojec me -Dare- a eHVAC HVACSYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 1 (Kitchen/Living) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE:2 (Living/Guest Loft) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 3 (Master Bed) - Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Locction / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 1 (Kitchen/Livina) Split Air Conditioner 12.0 SEER Ducts In Attic 4.2 Setback ZONE 2 (Living/Guest Loft) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 3 (Master Bed) WATER HEATING SYSTEMS Rated 1 Tank Energy F . ac -1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value RHEEM HE 80-130 Large Gas Recirc/Time+Temp 1 130,000 80 0.95 0.0129 0.0 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr); electric resistance and heat pump water heaters, listenergy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS 0 9 0 l This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: McFadden/McIntosh Architects Address:. 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 Telephone: (760) 346-8014 Lic. (sig aur r (date) Enfo a nt Agen Name: Title/Firm: Address: Telephone: Name: Micah Combs Title/Firm: C.M. Energy Consulting Address: 72-925 Fred Waring Drive, Suite 204 Palm Desert, CA 92260 Telephone: (760)4.46-89W .0 Q-() j (signatur) (date) dat �) (signature/stamp) date Run Initiation Time: 08/10/04 16:24:57 Run Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:2 of 3 Certificate of Compliance: Residential p (Addendum) CF -1 R r -V H I T E Main House 8/10/04 ro/ect Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field E 0 0 0 0 •(- The HVAC System "ZONE 1 (Kitchen/Living)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residenti 11 Manu I. HIGH MASS Design(see C-211) - Verify Thermal Mass: 1535 sgft Tile in Mortar Interior Mass, 0.75" thick at Kitchen/Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1535 sgft Exposed Slab Floor, 4.00" thick at Kitchen/Living HIGH MASS Design(see C-211) - Verify Thermal Mass: 182 sgft Covered Slab Floor, 4.00" thick at Kitchen/Living The HVAC System "ZONE 2 (Living/Guest Loft)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C -2R) - Verify Thermal Mass: 593 sgft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 593 sgft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 54 sgft Covered Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C-211) - Verify Thermal Mass: 72 sgft Tile in Mortar Interior Mass, 0.75" thick at Guest Loft The HVAC System "ZONE 3 (Master Bed)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential A lanual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 313 sgft Tile in Mortar Interior Mass, 0.75" thick at Master Bed HIGH MASS Design(see C -2R) - Verify Thermal Mass: 313 sgft Exposed Slab Floor, 4.00" thick at Master Bed HIGH MASS Design(see C-211) - Verify Thermal Mass: 555 sgft Covered Slab Floor, 4.00" thick at Master Bed HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS prTho NERC rafar meal dn.-. —# #.e s:..1.I....�:a,...u.......-� �:--___.:_.__.:__ _�.�--- -----_ E - _— R _v.ub...a — ...— ..waJY1Ci1 Wei a IV1111 ai ie la e HVAG 5ystem ice rvmg includes Ketrigerant Charge and Airtlow uredit (ora ce i ie r rovide verification of the TXV, or measure the Refrigerant Charge and Airflow. ter mus The HVAC System "ZONE 2 (Living/Guest Loft)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HER must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. rater TheHV—ACystem "ZONE 3 aster Be) inc u es Refrigerant Charge and Airflow Credit or a T certified R rater provide verification of the TXV, or measure the Refrigerant Charge and Airflow. must Run InitiationTime: un Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number: 1086 Job Number: 0418.00 Page:3 of 3 0 Computer Method Summary ry (Par. 1 of 3) C -2R W H I T E Main House 8/10/04 ro ec e a e 10-566 Via Pessaro La Quinta Project Address C.M. Energy Consulting (760) 346-8014 ocumen a on Author Te ep one Computer Performance 15 Compliance Method (Package or ompu er Climateons Source Energy Use Standard Proposed (kBtu/sf-yr) Design Design • Space Heating 3.19 3.25 Space Cooling 32.45 32.20 Domestic Hot Water 7.49 5.62 Totals -4112 Wall 41.08 Percent better than Standard: 330 90 Wall 64 BUILDIRM• 60 Total Conditioned Floor Area: 3,805 ft2 Building Type: Single Fam Detached. Building Front Orientation: (South) 180 deg Number of Dwelling Units: 1.00 90 Number of Stories: 2 0.387 • 90 Wall BUILDING ZONE INFORMATION 0.057 Zone Name Floor Area Volume ZONE 1 (Kitchen/Living) ZONE 2 (Living/Guest Loft) •(` 'TONE ONE 3 (Master Bed) 0 • • OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Roof 918 0.026 0 0 Roof 365 0.030 0 0 Wall 233 0.057 330 90 Wall 26 0.057 330 90 Wall 64 0.057 60 90 Wall 152 0.057 150 90 Wall 179 0.057 150 90 Door 24 0.387 150 90 Wall 392 0.057 240 90 Roof 540 0.030 0 0 Wall 134 0.057 330 90 Roof 573 0.026 0 0 Wall 283 0.057 330 90 Wall 141 0.057 60 90 Wall 238 0.057 150 90 Wall 177 0.057 240 90 Roof 867 0.026 0 0 Wall 96 0.057 330 90 Wall 352 0.057 60 90 Wall 160 0.057 150 90 Wall 30 0.057 240 90 0 compliance Margin -0.06 0.25 1.86 4.7% BuIldInC venTilt Plan Ch3cklUate Field ec a e Floor Construction Type: [—] Raised Floor ® Slab Floor Total Fenestration Area: 21.1 % Total Conditioned Volume: 38,860 ft 3 Total Conditioned Slab Area: 3,232 ft 2 # of Units 1,717 17,359 0.45 1,220 12,995 0.32 868 8,506 0.23 Gains Y/N Form 3 Reference Thermostat Vent Zone Type Type Hgt. Area Conditioned Setback 8 n1a Conditioned Setback 8 n1a Conditioned Setback 8 n1a C/R-2 (R.38.2x .16) C/R-3 (R.38.2x .16) W-1 Wall (W.21.2x6.16) W-2 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-2 Wall (W.21.2x6.16) Solid Wood Door W-1 Wall (W.21.2x6.16) C/R-3 (R.38.2x .16) W-1 Wall (W.21.2x6.16) C/R-2 (R.38.2x .16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) C/R-2 (R.38.2x .16) 1 !x6.16) W-1 Wall (W.21.2x6.16) W-1 Wall (W.21.2x6.16) W-2 Wall (W.21.2x6.16) Location / Comments ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY ZONE 1 ONLY Living Area Living Area Guest Loft Guest Loft Guest Loft Guest Loft Guest Loft ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY ZONE 3 ONLY Run Initiation Time: 08/10/0416:24:57 Run Code: 1092180297 EnergyPm 3.1 By EnergySoft User Number. 1088 Job Number. 0418.00 Page:1 of 6 0 Computer Method Summary rY (Pari 2 of 3) C -2R H I T E Main House 0 # Type 8/10/04 -Date U- Act. Glazing Type Location/ Area Factor SHGC Azm. Tilt Comments 0.680 1 Skylight Rear (North) 2.5 0.53 2 Window Rear (Northwest) 48.0 330 3 Window Rear (Northwest) 12.0 90 Sierra Pacific Mtl. Clad 4 Window Rear (Northwest) 144.0 ZONE 1 ONLY 5 Window Right (Northeast) 30.0 0.510 6 Window Front (Southeast) 45.0 0.53 7 Window Front Southeast) 20.0 240 8 window Front (Southeast) 20.0 90 Sierra Pacific Md. Clad 9 Window Left (Southwest) 48.0 ZONE 1 ONLY 10 Window Left (Southwest) 26.7 0.510 11 Window Left (Southwest) 12.0 0.53 12 Window Left (Southwest) 20.0 330 13 Window Rear (Northwest) 12.0 90 Sierra Pacific Mtl. Clad 14 Window Rear (Northwest) 12.0 Guest Loft 15 Window Rear (Northwest) 48.0 0.510 16 Window Rear (Northwest) 48.0 0.53 17 Window Rear (Northwest) 1.0 X30 18 Window Rear (Northwest) -To- .019 90 Sierra Pacific Mtl. Clad T9 Window Rear (Northwest) 1.0 Guest Loft 20 Window Rear (Northwest) 1.0 0.510 21 Window Rear (Northwest) ----f.-0 0.53 22 Window Rear (Northwest) 1.0 -9D 23 Window Right (Northeast) 16.0 SolaTube(Defa-uffTSVy-rjfe- 24 Window Front (Southeast) 10.0 ZONE 3 25 Window Front (Southeast) 16.0 en. Hgt. 26 Window Front (Southeast) 10.0 37 Window ron ou east) --48:6 6198 .Tit Bug Screen Skylightear -0 o �2 �- Window Rear (Northwest) Bug Screen INTERIOR AND EXTERIOR SHADING --Ta # Exterior Shade Type SHGC 0.680 0.55 0 0 SolaTube (Default) Skylite ZONE 1 ONLY 0.510 0.53 330 408e Pacific Mtl. Clad ZONE 1 ONLY 0.510 0.53 330 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 0.510 0.40 330 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 0.510 0.53 60 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 0.960 0.53 150 90 Double Tinted Default (NM) ZONE 1 ONLY 0.510 0.53 150 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 0.0 0.53 150 90 Sierra Pacific Mtl. Clad 0.0 0.510 0.53 240 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 0.510 0.53 240 90 Sierra Pacific Md. Clad ZONE 1 ONLY 0.510 0.53 240 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 0.510 0.40 240 90 Sierra Pacific Mtl. Clad ZONE 1 ONLY 0.510 0.53 330 90 Sierra Pacific Mtl. Clad Living Area 0.510 0.53 330 90 Sierra Pacific Mtl. Clad Living Area 0.510 0.40 330 90 Sierra Pacific Mtl. Clad Living Area 0.510 0.40 330 90 Sierra Pacific Mtl. Clad Living Area 0.510 0.53 330 90 Sierra Pacific Mtl. Clad Guest Loft 0.510 0.53 330 90 Sierra Pacific Mtl. Clad Guest Loft 0.510 0.53 330 90 Sierra Pacific Mtl. Clad Guest Loft 0.510 0.53 330 90 Sierra Pacific Mtl. Clad Guest Loft 0.5 0.53 X30 90 terra Pacific Mtl. aGuest Loft 0.510 0.53 330 90 Sierra Pacific Mtl. Clad Guest Loft 0.510 0.53 60 90 Sierra Pacific Mtl. Clad Guest Loft 0.510 0.53 150 90 Sierra Pacific Mtl. Clad Guest Loft 0.510 0.53 150 90 Sierra Pacific Mtl. Clad Guest Loft 0.510 -U-5W 0.53 150 90 Sierra Pacific Mtl. Clad Guest Loft _UXW 15 -9D Sierra Pacific a uesLoft -0 55 �- ----U SolaTube(Defa-uffTSVy-rjfe- ZONE 3 ONLY 0.53 330 90 Sierra Pacific Mtl. Clad ZONE 3 Window 7.0 Overhang Left Fin Right Fin st en. Hgt. I -Ext. RExt. Dist. Len. Hgt. ist. Len. Hgt. Run Initiation Time: 08/10/0416:24:57 Run Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:2 of 6 0 2 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4 Bug Screen 0.76 8.0 12.0 7.0 0.1 7.0 7.0 6 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 8.0 12.0 7.0 0.1 7.0 7.0 T Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 V- Bug Screen ---TT6- --n --" �0 --n -0 -" 9 Bug Screen 0.76 0.0 --10-0 0.0 0.0 0.0 0.0 10 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 T1 ug creen -M --V0 --n --n --n --n --" T2 Bug Screen ---076 8.0 -1-20 7.0 0.1 7.0 T1 Bug Screen 0.0 0.0 0.0 0.0 0.0 0.0 T4 Bug Screen 0.0 0.0 0.0 0.0 0.0 0.0 15 Bug Screen ---"6- --" --M --n -yl -'T.0 -T0 % Bug Screen -0'! 8.0 12.0 7.0 0.1 7.0 7.0 17 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 .Tit Bug Screen -0 --" -:0 --n 0 % Bug Screen --Ta --n pro �0 ''0 Bug Screen --n -0-0 --0-0 W B ug creen --V76- 0.0 0.0 0.0 ---0-0 0.0 0.0 22 Bug Screen 0.76 0.0 0.0 0.0 --yo- 0.0 0.0 23 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 24 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 25 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 26 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 '*(j2 27 ug Screen 0.76 8.0 2 0 7.0 0.1 7.0 7.0 �8 one 29 ug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Run Initiation Time: 08/10/0416:24:57 Run Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:2 of 6 0 0 Computer Method Summary ry (Parti 2 of 3) C -2R W H I T E Main House 8/10/04 roe a ae � U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 30 Window Rear (Northwest) 24.0 0.510 0.53 330 90 Sierra Pacific Mtl. Clad ZONE 3 ONLY 31 Window Rear (Northwest) 20.0 0.510 0.40 330 90 Sierra Pacific Mtl. Clad ZONE 3 ONLY 32 Window Right (Northeast) 12.5 0.770 0.59 60 90 Double Tinted Default (NW) ZONE 3 ONLY 33 Window Right (Northeast) 35.0 0.510 0.53 60 90 Sierra Pacific Mtl. Clad ZONE 3 ONLY 34 Window Right (Northeast) 12.5 0.490 0.46 60 90 Sierra Pacific Mtl. Clad ZONE 3 ONLY • 35 Window Right (Northeast) 10.0 0.510 0.53 60 90 Sierra Pacific Mtl. Clad ZONE 3 ONLY 36 Window Right (Northeast) 10.0 0.510 0.53 60 90 Sierra Pacific Mtl. Clad ZONE 3 ONLY OU INTERIOR AND EXTERIOR SHADING # Window Overhang Left Fin Right Fin Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 ug Green 31 Bug Screen 0.76 8.0 12.0 7.0 0.1 7.0 7.0 32 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 33 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 34 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 Run Initiation Time: 08/10/04 16:24:57 Run Code: 1092180297 EnergyPro 3.1 By Ener Soft User Number. 1088 Job Number. 0418.00 Page:3 of 8 0 Computer Method Summary (Part 3 of 3) C -2R ,W H I T E Main House 8/10/04 THERMAL MASS FOR HIGH MASS DESIGN Ratedl F2 Insulation Water Heater Water Heater Distribution Area Thick. Heat R -Val. Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar 1,535 0.75 24 0_67 n/a 0 ZONE 1 ONLY / Interior Mass Concrete, Heavyweight 1,535 4.00 28 0.98 n/a 0 ZONE 1 ONLY / Slab on Grade Concrete, Heavyweight 182 4.00 28 0.98 n/a 2 ZONE 1 ONLY / Slab on Grade Tile in Mortar 593 0.75 24 0.67 n/a 0 Living Area / Interior Mass Concrete, Heavyweight 593 4.00 28 0.98 n/a 0 Living Area / Slab on Grade PERIMETER LOSSES HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 1 (Kitchen/Living) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 2 (Living/Guest Loft) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 3 (Master Bed) ,( )ydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 1 (Kitchen/Living) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 2 (Living/Guest Loft) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 3 (Master Bed) WATER HEATING SYSTEMS Ratedl F2 Insulation Water Heater Water Heater Distribution Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 59 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 80 0.76 0.0 0 ZONE 1 ONLY Slab Perimeter 15 0.76 0.0 0 Living Area Slab Perimeter 2 0.76 0.0 0 Living Area Slab Perimeter 84 0.76 0.0 0 ZONE 3 ONLY HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 1 (Kitchen/Living) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback ZONE 2 (Living/Guest Loft) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback ZONE 3 (Master Bed) ,( )ydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 1 (Kitchen/Living) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 2 (Living/Guest Loft) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback ZONE 3 (Master Bed) WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type . Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. RHEEM HE 80-130 Large Gas Recirc/Time+Temp 1 130,000 80 0.95 0.0129 0.0 1 For small gas storage (rated input <= 75000 BMW), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 08/10/0416:24:57 Run Code: 1092180297 1 EnergyPro 3.1 By Energysoft User Number. 1086 Job Number. 0418.00 Page:4 of 6 1 0 0 HVAC SYSTEMS Heating Equipment Type (furnace, heat 40 pump, etc.) Minimum Distribution Type Efficiency and Location Duct Thermostat Loca7on / (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments A()Iydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater .Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input> 75000 Btu/hr), list Rated Input, Recovery Efficiency and Stancby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 08/10/0416:24:57 Run Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:5 of 6 Computer Method Summary ry (Part 3 of 3) C -2R W H I T E Main House 8/10/04 (jr—co ee Date THERMAL MASS FOR HIGH MASS DESIGN • Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 54 4.00 28 0_98 n/a 2 Living 4rea / Slab on Grade Tile in Mortar 72 0.75 24 0.67 n/a 0 Guest Loft / Interior Mass Tile in Mortar 313 0.75 24 0.67 n/a 0 ZONE 3 ONLY / Interior Mass Concrete, Heavyweight 313 4.00 28 0.98 n/a 0 ZONE 3 ONLY / Slab on Grade Concrete, Heavyweight 555 4.00 28 0.98 n/a 2 ZONE 3 ONLY / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments 0 HVAC SYSTEMS Heating Equipment Type (furnace, heat 40 pump, etc.) Minimum Distribution Type Efficiency and Location Duct Thermostat Loca7on / (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments A()Iydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater .Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated Input> 75000 Btu/hr), list Rated Input, Recovery Efficiency and Stancby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 08/10/0416:24:57 Run Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:5 of 6 0 Computer Method Summary (Addendum) C -2R H I T E Main House 8/10/04 Date • Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field r, u 0 0 0 The HVAC System "ZONE 1 (Kitchen/Living)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residenti 31 Manu I. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1535 sqft Tile in Mortar Interior Mass, 0.75" thick at Kitchen/Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1535 sqft Exposed Slab Floor, 4.00" thick at Kitchen/Living HIGH MASS Design(see C-211) - Verify Thermal Mass: 182 sqft Covered Slab Floor, 4.00" thick at Kitchen/Living The HVAC System "ZONE 2 (Living/Guest Loft)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manu 1. HIGH MASS Design(see C-211) - Verify Thermal Mass: 593 sqft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C-211) - Verify Thermal Mass: 593 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 54 sqft Covered Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 72 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Loft The HVAC System "ZONE 3 (Master Bed)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential'11 lanual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 313 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Bed HIGH MASS Design(see C-211) - Verify Thermal Mass: 313 sqft Exposed Slab Floor, 4.00" thick at Master Bed HIGH MASS Design(see C-211) - Verify Thermal Mass: 555 sqft Covered Slab Floor, 4.00" thick at Master Bed HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS nrevidP_r_ Tho MFRS rafnr mimt rinrrumran4 fho Feiri —ifi— in., enA dim.. m^ 6:.. *e 6; ....t ar..,....... ., c_— nV — ------- ---- ---•-- •---....---................_.....,...................a ... ava....a w anvav ii—SUMS on a nrnn ..rvrc. an le la e HVAC tsystem --Z0Nh 1 (Kitchen/Living)-' includes Refrigerant Charge andWffloTWW recit ora certified KLKb r. rovide verification of the TXV, or measure the Refrigerant Charge and Airflow. ter mus The HVAC System "ZONE 2 (Living/Guest Loft)" includes Refrigerant Charge and Airflow Credit (or a TXV). Acer tified HERS must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. rater The HVAC System "ZONE 3 Master Bed)" includes Refrigerant Charge and Airflow Credit ora V). A certi a rater provide verification of the TXV, or measure the Refrigerant Charge and Airflow. must Run InitiationTime: un Code: 1092180297 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0418.00 Page:e of 8 0 lu 0 00 IF, 0 E 0 • • 0 0 U • C' PROPOSED CONSTRUCTION ASSEMBLY ENV -3 W H I T E Main House 8/10/04 SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 ASSEMBLY NAME C/R-2 (R.38.2x_.16) Air Space 5 ASSEMBLY Floor Gypsum or Plaster Board 7 TYPE (check one) Wall 3.86 9 1.39 Ceiling / Roof INSIDE SURFACE AIR FILM 0.610 W 25.65 FRAMING MATERIAL yy� Z FRAMING % 10 %o Framing /o 14.3 TOTAL HC 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 0.39 8 3.86 9 1.39 2.50 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ ❑ (3� ® ❑ El El El 0.170 0.250 0.010 0.625 2.000 1.500 0.625 0.800 11.880 38.000 11.385 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.210 0.210 0.060 0.060 0.775 0.775 0.800 11.880 38.000 11.385 0.562 0.562 0.39 1.36 3.86 0.36 1.39 2.50 0.6101 0.610 41.19 25.65 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) 1 / Rc 1 - (Fr% / 100) 2.50 0.24 0.60 0.06 0.35 0.02 1.77 0.29 0.51 3.491 0.39 1.36 3.86 0.36 1.39 2.50 0.26 0.68 14.3 TOTAL HC 4.6 RV rc' *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framino members [ 0.0243 X 0.90 ] + L 0.0390 X 0.10 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySok User Number. 1086 Job Number. 0418.00 Page:1 of 5 0 0 0 17, 11 A 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 l W H I T E Main House 8/10/04 FRAMING SUBTOTA R -VALUE DESCRIPTION WOOD FRAME R VALUE OUTSIDE SURFACE AIR FILM ASSEMBLY NAME C/R-3 (R.38.2x_.16) Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor Plywood 4 TYPE Wall (check one) 5 � IL Ceiling / Roof 0.51 H 93 FRAMING MATERIAL yy� 8 0 Z FRAMING % 10 %o Framing /o 0.68 15% (16" o.c. Wall) 0.610 40.39 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) FRAMING SUBTOTA R -VALUE DESCRIPTION WOOD FRAME R VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-38 5 Gypsum or Plaster Board 6 0.51 7 0.36 8 2.60 9 0.68 INSIDE SURFACE AIR FILM FRAMING SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R VALUE 0.170 0.170 0.210 0..210 0.060 0.060 0.775 0.775 38.0001 11.385 0.562 0.562 0.51 3.86 0.36 1.39 2.60 0.26 0.68 0.6101 0.610 40.39 13.77 *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) 1 / Rc 1 (Fr -/o/ 100) 2.50 0.24 0.60 0.06 0.35 0.02 1.77 0.29 0.51 3.86 0.36 1.39 2.60 0.26 0.68 1 Q,$ TOTAL HC 3.2 R4 RI *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framina members [ 0.0248 X0.90 ] + [ 0.0726 X 0.10 1 / Rc 1 (Fr -/o/ 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0418.00 Pagel of 5 .0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 W H I T E Main House 8/10/04 DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ 0- El E Q INSIDE SURFACE AIR FILM Weight and Specific Heat values for materials penetrated IN I!fl R -VALUE *HEAT CAPACITY (Optional) ASSEMBLY NAME linterior Air Wall CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) ASSEMBLY Floor — — — TYPE (check one) Wall C Ceiling / Roof IL 3 NFRAMING MATERIAL None 4 ? FRAMING % �% o Framing /o 5 15% (16" o.c. Wall). 6 12% (24" o.c. Wall) 7 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 8 7% (24" o.c. Floor/Cell.) DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ 0- El E Q INSIDE SURFACE AIR FILM Weight and Specific Heat values for materials penetrated IN I!fl R -VALUE *HEAT CAPACITY (Optional) THICK- NESS (in.) CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) — 0.170 — — — 1 2 3 4 5 6 7 8 9 'NOTE: — 0.680 — — — SUBTOTA by 0.85 0.0 TOTAL HC members. 0.0 wood framing include the effects of the framing [� X �] + [ X 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:3 of 5 0 • 0 0 0 • 0 0 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 W H I T E Main House 8/10/04 SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ASSEMBLY NAME W-1 Wall (W.21.2x6.16) Stucco 2 Membrane, Vapor -Permeable Felt ASSEMBLY Floor Plywood 4 TYPE Wall (check one) 5 0 Ceiling / Rocf 0.31 W 0.37 8 aFRAMING MATERIAL yy� 0.68 z FRAMING % 15 Framing /o o.sso 23.11 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) FRAMING ❑ ❑ ❑ pq ❑ El D a 0.170 0.875 0.010 0.375 5.500 0.625 0.465 21.000 5.445 0.562 0.562 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.562 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 r0,6801 o.sso 23.11 7.56 *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 1 / Rc 1 - (Fr% / 100) 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.8 TOTAL HC 3.7 RG Rr 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the foaming members. [ 0.0433 X 0.85 + 0.1323 X 0.15 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:4 of 5 1 • 1PROPOSED CONSTRUCTION ASSEMBLY ENV -3 1 0 • PROJECT NAME DATE W H I T E Main House 8/10/04 L=1 0 `-r ANI DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ASSEMBLY NAME W-2 Wall (W.21.2x6.16) Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 ASSEMBLY Floor Gypsum or Plaster Board 4 TYPE Wall (check one) 5 LU Ceiling / Roof 0.68 W 8 o. FRAMING MATERIAL yy� n Z 0 FRAMING % 15 % Framing % 0.680 22.981 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) L=1 0 `-r ANI SUBTOTA R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Insulation, Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.37 5 2.60 6 0.68 7 8 9 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) FRAMING ❑ [3q ❑ El El El 0.170 0.625 5.500 0.625 5.445 0.562 0.562 0.37 0.98 2.60 0.26 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 21.000 5.445 0.562 0.562 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 22.981 7.42 *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Stu/F-Ib) HC (A X 8) (Btu/F-sf) X 0.15 I 2.60 0.26 0.68 2.53 0.37 0.98 2.60 0.26 0.68 $ TOTAL HC 2.3 TE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the taming members. 0.0435 X0.85 ] + [ 0.1348 X 0.15 I 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U-VALI EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number: 0418.00 Page:5 of 5 0 0 0 LJ 00 U n 0 0 • Architecture Planning Interiors Engineering • s A JOINT VENTURE ' • Christopher McFadden Architect C 17837 • s James G. McIntosh Architect C 24267 s ' Tel: (760) 346-8014 Fax (760) 568-0963 s s 72-925 Fred Waring Dr. /204 Palm Desert, Co. 92260 • 7�Jla`I`. Square Footage "� R -Value: Attic Area Walls Total Perimeter - ` Ceiling GLASS AREAS I See Accompanying Glazing Takeoffs Total Glazing Area =-I�®or '20.b% Floor Tile = 1(_,A2 Carpet Area = b2 Tile Edge = Carpet Edge = Weighted Average Ceding Height CTION A SS E M BLI ES W-1 (Ext) W-2 (Garage) v- W-3 (Veneer) _ S.C. Doors _ \-Iu `141C)A cam@ �►'-3°- 55� 1`�� CEILING CS .,a. CA_= 5 "2� IU tD' -p' — 161 ® \ \� -2= 1 11.e0 -Z.ot-1 .q6i. 'E405 rs� = S -IA (E CON STRU CTION A SS E M BLI ES W-1 (Ext) W-2 (Garage) v- W-3 (Veneer) _ S.C. Doors _ C/R-1 (Flat) si C/R-2 (Vent) a q. C/R-3 (Vault) = 3 Skylights WALLS CEILING P, • 0 90 • 00 0 • Architecture Planning Interiors Engineering ' • A JOINT V E N TURE ' • Christopher McFadden Architect C 17837 • • James G. McIntosh Architect C 24267 • ' Tel: (760) 346-8014 Fax (760) 568-0963 « 72-925 Fred Waring Dr. /204 Palm Desert, Co. 92260 G L A Z I N G A R E A S • SUBSTANTIALLY SHADED—OVERHANG LENGTH HAS BEEN SET TO GLASS HEIGHT AS OVERHANG EXCEEDS C.E.C. RESTRICTIONS North East symbols size sq. ft. overhang symbols size sq. ft. overhang Ab F F f,0NEt— AA -2-6A W-1— W-1?ice-2S W-2 - W-2 — ..._ 6 • 00 • 0 • 0 Architecture Planning Interiors Engineering • A JOINT VENTURE • • Christopher McFadden Architect C 17837 • James G. McIntosh Architect C 24267 ' Tel: (760) 346-8014 Fax (760) 568-0963 • s 72-925 Fred Waring Dr. /204 Palm Desert, Co. 92260 G L A Z I N G A R E A S • SUBSTANTIALLY SHADED—OVERHANG LENGTH HAS BEEN SET TO GLASS HEIGHT AS OVERHANG EXCEEDS C.E.C. RESTRICTIONS SouthI F West symbols size sq. ft. overhang symbols size sq. ft. overhang Ca X,v = �v fFCL M -2- A 'AP = 2�,C w-1 W-2 ezo \o(0.cOG W-1 - W-2 — t J •• Architecture Planning Interiors Engineering • A J 0 IN T VE N T U RE ' • Christopher McFadden Architect C 17837 • James G. McIntosh Architect C 24267 + ' Tel: (760) 346-8014 Fax (760) 568-0963 + • 72-925 Fred Waring Dr. 1204 Palm Desert, Ca. 92260 + so 'C J Square Footage �)���5 � R–Value- Attic Area Walls Zt� Total Perimeter \U0 `^ 1Ceiling GLASS AREAS See Accompanying Glazing Takeoffs Total Glazing Area=-22(oor Ifj.-j % Floor Tile = Af-00(0 Carpet Area = SA Tile Edge � ,_ Carpet Edge = 1 _ 1 Weighted Average Ceiling HeigFt -;.5o@ t9j ro = 2AO Ze 3 z� Ido' cs-rs 0 - CON STRUCTION ASSEMBLIES W-1 (Ext) = W-2 (Garage) – W-3 (Veneer) = S.C. Doors – --- C/R-1 (Flat) _ C/R-2 (Vent) _ C/R-3 (Vault) = p0(/ kM R--- _ j7– SkylightsIF — WALLS CEILING Architecture Planning Interiors Engineering « A JOINT VENTURE • Christopher McFadden Architect C 17837 « « James G. McIntosh Architect C 24267 • • Tel: (760) 346-8014 Fax (760) 568-0963 « « 72-925 Fred Waring Dr. J204 Palm Desert, Co. 92260 « GLAZI NG AREAS « SUBSTANTIALLY SHADED–OVERHANG LENGTH HAS BEEN SET TO GLASS HEIGHT AS OVERHANG EXCEEDS C.E.C. RESTRICTIONS NorthI East symbols size sq. ft. overhang 2 C;42, 12 F • � a �2 Y •0 0 W-1 W-2 -4 symbols size sq. ft. overhang W-1– \ -.�A 1 W-2 – — 0 • Architecture Planning Interiors Engineering « { 1 A J O I N T V E N T U R E « • Christopher McFadden Architect C 17837 « James G. McIntosh Architect C 24267 « ' Tel: (760) 346-8014 Fax (760) 568-0963 « 72-925 Fred Waring Dr. /204 Palm Desert, Co. 92260 « • C i .O 0 0 •c � 0 GLAZI NG AREAS • SUBSTANTIALLY SHADED—OVERHANG LENGTH HAS BEEN SET TO GLASS HEIGHT AS OVERHANG EXCEEDS C.E.C. RESTRICTIONS Sou th West symbols size sq. ft. overhang symbols size sq. ft. overhang 2 X 4' f co F GCS E , _ `J - b o W-1 — W-1 - W-2 — W-2 s '_ • Architecture Planning Interiors Engineering • • A J O I N T V E N T U R E ' • Christopher McFadden Architect C 17837 • • • James G. McIntosh Architect C 24267 ' Tel: (760) 346-8014 Fax (760) 568-0963 • • 72-925 Fred Waring Dr. #204 Palm Desert. Co. 92260 • • • .O 0 • a 6C I 0 Square Footage .(.0y Attic Area Total Perimeter M 13 R— Value: Walls ` Ceiling GLASS AREAS See Accompanying Glazing Takeoffs Total Glazing Area = k1% or k-1. X Floor Tile= '1 �� Carpet Area t I Tile Edge = .. — Carpet Edge = D ��� It Weighted Average Ceiling Height W-1 (Ext) = W-2 (Garage) _ W-3 (Veneer) = — S.C. Doors — C/R-1 (Flat) _ — C/R-2 (Vent) _ C,V C/R-3 (Vault) SkylightsIF- . WALLS 3tv.)-(Z- 257-e � v 257- e -- --C --0- -N --C--O--N STRU CTION ASSEMBLIES W-1 (Ext) = W-2 (Garage) _ W-3 (Veneer) = — S.C. Doors — C/R-1 (Flat) _ — C/R-2 (Vent) _ C,V C/R-3 (Vault) SkylightsIF- . WALLS .CEILING 0 • Architecture Planning Interiors Engineering ' • A JOINT VENTURE • Christopher McFadden Architect C 17837 0 . James G. McIntosh Architect C 24267 • Tel: (760) 346-8014 Fax (760) 568-0963 • • 72-925 Fred Waring Dr. 1204 Palm Desert, Ca. 92260 G L A Z I N G A R E A S 0 ' SUBSTANTIALLY SHADED—OVERHANG LENGTH HAS BEEN SET TO GLASS HEIGHT AS OVERHANG EXCEEDS C.E.C. RESTRICTIONS 0 0 • 0 0 • • L] North East symbols size sq. ft. overhang symbols size sq. ft. overhang t Fur+ X L � 3° �v° e F O 2�12•CS F w-1 - 1(0 A G ( W-1 — ^1-.012 06 T�2. W-2 — W-2 — .�— 0 • ( Architecture Planning Interiors Engineering • (� A JOINT VENTURE • ' Christopher McFadden Architect C 17837 • • James G. McIntosh Architect C 24267 • ' Tel: (760) 346-8014 Fax (760) 568-0963 • • 72-925 Fred Waring Dr. /204 Palm Desert, Ca. 92260 G L A Z I N G A R E A S • SUBSTANTIALLY SHADED -OVERHANG LENGTH HAS BEEN SET TO GLASS HEIGHT AS OVERHANG EXCEEDS C.E.C. RESTRICTIONS • 41 so a 0 0 0 V 0 SouthI F7 West symbols size sq. ft. overhang symbols size sq. ft. overhang 1yp �'C�F-C�-k�R• Cil-AcZlN.fo� .s W-1 - COO W-2 W-1 a Wi-2 - 0 0 Table 1-D Default Fenestration Product U -Factors • I • • • • •0 Metal includes any field -fabricated product with metal cladding. Non-metal framed fenestration products with metal cladding must add 0.04 to the listed U -factor. Non -Metal frame types can incluce metal fasteners, hardware, and door thresholds. Thermal break product design characteristics are: a. The material used as the thermal break must have a thermal conductivity of not more than 3.6 Btuf nch/hr/ft2/`F, b. The thermal break must produce a gap of not less than 0.210", and c. All metal members of the fenestration product exposed to interior and exterior air must incorporate a thermal break meeting the criteria in (a) and (b) above. In addition, the fenestration product must be clearly labeled by the manufacturer that it qualifies as a hermally broken product in accordance with this standard. 2 For all dual glazed fenest%UQn products, adjust the listed U -factors as follows: a. Subtract 0.05 for spacers of 7/16" or wider. b. Subtract 0.05 for products certified by the manufacturer as low -E glazing. c. Add 0.05 for products with dividers between panes if spacer is less than 7/16" wide. d. Add 0.05 to any product with true divided lite jdividers through the panes). 1 INI71 �A�[ES �EATUI�) llrILIZFD WITNI�I'f1ts LoM If<j�jG GALGIJLATION ung a ane "U-Fa Frame Type' Product Type U -Factor Metal Operable 1.28 0.87 Metal Fixed 1.19 0.72 Metal Greenhouse/Garden window 2.26 1.40 Metal Doors 1.25 0.85 Metal Skylight 1.72 0.941 e a , "ermal breaKOperable 0.11 Metal, Thermal*Break Fixed 0.60 Metal, Thermal Break Greenhouse/Garden window 1.12 Metal, Thermal Break Doors 0.64 Metal, Thermal Break Skylight 0.81 Non -Metal Operable 0.99 Non -Metal Fixed 1.04 0.57 Non -Metal Greenhouse/Garden window 0.99 0.5E Non -Metal Doors 1.94 1.0E Non -Metal Skylight 1.47 1 0.6E Metal includes any field -fabricated product with metal cladding. Non-metal framed fenestration products with metal cladding must add 0.04 to the listed U -factor. Non -Metal frame types can incluce metal fasteners, hardware, and door thresholds. Thermal break product design characteristics are: a. The material used as the thermal break must have a thermal conductivity of not more than 3.6 Btuf nch/hr/ft2/`F, b. The thermal break must produce a gap of not less than 0.210", and c. All metal members of the fenestration product exposed to interior and exterior air must incorporate a thermal break meeting the criteria in (a) and (b) above. In addition, the fenestration product must be clearly labeled by the manufacturer that it qualifies as a hermally broken product in accordance with this standard. 2 For all dual glazed fenest%UQn products, adjust the listed U -factors as follows: a. Subtract 0.05 for spacers of 7/16" or wider. b. Subtract 0.05 for products certified by the manufacturer as low -E glazing. c. Add 0.05 for products with dividers between panes if spacer is less than 7/16" wide. d. Add 0.05 to any product with true divided lite jdividers through the panes). 1 INI71 �A�[ES �EATUI�) llrILIZFD WITNI�I'f1ts LoM If<j�jG GALGIJLATION • 0 Table 1-E Default Solar Heat Gain Coefficient Metal Operable Clear 0.80 0.70 Metal Fixed Clear 0.83 0.73 Metal Operable Tinted 0.67 0.59 Metal Fixed Tinted 0.68 0.60 e a , ermal breakOperable Clear 0.12 0.63 Metal, Thermal Break Fixed Clear 0.78 0.69 Metal, Thermal Break Operable Tinted 0.60 0.53 Metal, Thermal Break Fixed Tinted 0.65 0.57 on- e a Operable "e Mar 0.74 0.65 Non -Metal Fixed Clear 0.76 0.67 Non -Metal Operable Tinted 0.60 0.53 Non -Metal Fixed Tinted 0.63 0.55 ons%. _ aoiar neat amain 1.oemcient ,so I • • ► INICa s��Tu�Cs� uTiL1z�p wIPHI�t This GOI"1j�Ll� GE GALS-ULNTIoN 00 LIM P • • • 0 {j • • • 9 0 Thermal Performance Data PRODUCT LINE DESCRIPTION & Glazing Variations THERMAL PERFORMANCE QVVINTER AHTIM%IZED UNITS SHGC Vt "U" Co U tot. Res U tot. I NRes Res NRes Res NRes CLAD CASEMENT UNITS AA (Res)- 24 x 48 BB (NRes) - 30 x Single Glaze, Simulite Clear, 1.5" width grid 1.12 1.00 1.02 0.55 0.53 0.54 0.54 Single Glaze, Simulite, Clear, .75" width grid 1.12 1.00 1.02 0.60 0.59 0.60 0.61 Single Glaze, One Lite, Clear 1.12 1.00 1.02 0.65 0.65 0.66 0.69 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.52 0.51 0.49 0.45 0.49 0.48 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.52 0.51 0.53 0.51 0.54 0.54 3/4" IG, One Lite, Clear 0.49 0.52 0.51 0.58 0.96 0.59 0.61 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.38 0.36 0.28 0.27 0.43 0.43 3/4 IG, Simulite, Low E' .75" width grid 0.30 0.38 0.36 0.30 0.30 0.48 0.48 3/4" IG, One Lite, Low E' 0.30 0.38 0.36 0.32 033 0.52 0.54 CLAD AWNING UNITS AA (Res)- 48 x 24 BB (NRes) -,d0 x 40 Single Glaze, Simulite Clear, 1.5" width grid 1.12 1.00 1.02 0.54 0.55 0.54 0.58 Single Glaze Simulite, Clear, .75" width grid 1.12 1.00 1.02 0.59 0.30 0.59 0.63 Single Glaze, One Lite, Clear 1.12 1.00 1.02 0.64 0a5 0.65 0.69 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.52 0.51 0.48 0.48 0.48 0.51 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.52 0.51 0.53 052 0.53 0.56 3/4" IG, One Lite, Clear 0.49 0.52 0.51 0.57 056 1 0.59 0.61 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.38 0.36 0.27 0.28 0.43 0.45 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.38 0.36 0.30 030 1 0.47 0.49 3/4" ISG, One Lite, Low E' 0.30 0.38 0.36 0.32 0.33 0.52 0.54 CLAD FIXED UNITS AA (Res) - 48 x 48 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 1.04 1.05 0.59 0.57 0.59 0.60 Single Glaze, Simulite, Clear, .75" width grid 1.12 1.04 1.05 0.65 0 r64 0.66 0.67 Single Glaze, One Lite, Clear 1.12 1.04 1.05 0.72 030 0.74 0.75 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.51 0.51 0.53 049 0.54 0.53 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.51 0.51 0.58 0-55 0.60 0.60 3/4" IG, One Lite, Clear 0.49 0.51 0.51 1 0.64 1 061 1 0.67 0.67 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.35 0.34 0.29 029 0.47 0.47 3/4 IG, Simulite, Low E', .75" width rid 0.30 0.35 0.34 0.32 --16-3-2-1-10.53 0-53 3/4" IG, One Lite, Low E' 0.30 0.35 0.34 0.35 OL35 1 0.59 0.59 CLAD DIRECT GLAZE UNITS AA (Res) - 48 x 48 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 1.12 1.12 0.64 0.61 0.65 0.65 Single Glaze, Simulite, Clear, .75" width grid 1.11 1.12 1.12 0.71 C68 0.73 0.72 Single Glaze, One Lite, Clear 1.11 1.12 1.12 0.78 C.75 0.80 0.80 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.52 0.51 0.57 C-53 0.59 0.57 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.52 0.51 0.63 C.58 0.66 0.64 3/4" IG, One Lite, Clear 0.49 0.52 0.51 1 0.69 C.64 1 0.73 0.71 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.35 0.34 0.31 C.31 0.52 0.51 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.35 0.34 0.34 1 C.34 1 0.58 0.57 3/4" IG, One Lite, Low E' 0.30 0.35 0.34 0.38 0.37 0.64 0.63 CLAD DIRECT GLAZE SASH SET UNITS AA (Res)- 48 x 48 BB (NRes) --48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 1.02 1.04 0.58 0.57 0.59 0.60 Single Glaze, Simulite, Clear, .75" width grid 1.11 1.02 1.04 0.65 0.63 0.66 0.67 Single Glaze, One Lite, Clear 1.11 1.02 1.04 0.72 6.70 0.74 0.75 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.49 0.49 0.64 6.60 0.67 0.67 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.49 0.49 0.64 0.60 0.67 0.67 11 0 0 0 0 60 0 W 0 0 10 3/4" IG, One Lite, Clear 0.49 1 0.49 0.49 0.64 0.60 0.67 0.67 3/4 IG, Simulite, Low E", 1.5" width grid 0.30 0.33 0.32 0.29 0.28 0.47 0.47 3/4 IG, Simulite, Low E•, .75" width grid 0.30 0.33 0.32 0.32 0.31 0.53 0.53 3/4" IG, One Lite Low E' 0.30 0.33 0.32 0.35 0.34 0.59 0.59 CLAD HORIZONAL SLIDER UNITS AA (Res) - 60 x 36 BB (NRes) - 72 x 48 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 0.97 1.00 0.51 0.53 0.51 0.55 Single Glaze, Simulite, Clear, .75" width grid 1.12 0.97 1.00 0.57 0.58 0.57 0.61 Single Glaze, One Lite, Clear 1.12 0.97 1.00 0.63 0.64 0.64 0.68 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.51 0.51 0.46 0.46 0.46 0.49 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.51 0.51 0.51 0.50 0.52 0.54 3/4" IG, One Lite, Clear 0.49 1 0.51 0.51 0.56 0.55 0.58 0.60 3/4 IG, Simulite, Low E", 1.5" width grid 0.30 0.37 0.36 0.26 0.27 0.40 0.43 3/4 IG, Simulite, Low E', .75' width grid 0.30 0.37 0.36 0.29 0.29 0.46 0.48 3/4" IG, One Lite, Low E' 0.30 0.37 0.36 0.31 0.32 0.51 0.53 CLAD DOUBLE HUNG UNITS AA (Res) - 36 x 60 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 0.95 0.98 0.51 0.53 0.51 0.55 Single Glaze, Simulite, Clear, .75" width grid 1.12 0.95 0.98 0.57 0.58 0.57 0.61 Single Glaze, One Lite, Clear 1.12 0.95 0.98 0.63 0.64 0.64 0.68 3/4 IG Simulite, Clear, 1.5" width grid 0.49 0.49 0.50 0.46 0.46 0.46 0.48 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.49 0.50 0.51 0.50 0.52 0.54 3/4" IG, One Lite, Clear 0.49 0.49 0.50 0.56 1 0.55 1 0.58 0.60 3/4 IG, Simulite, Low E', 1.5' width grid 0.30 0.36 0.35 0.26 0.27 0.40 0.43 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.36 0.35 0.29 0.29 1 0.45 0.48 3/4" IG, One Lite, Low E' 0.30 0.36 0.35 0.31 0.32 1 0.51 0.53 CLAD DOUBLE HUNG PICTURE UNITS AA (Res) - 48 x 48 BB (NRes) - 48 x 72 Single Glaze, Simulite, Clear, 1.5" width grid 1.12 0.95 0.98 0.59 0.57 0.59 0.60 Single Glaze, Simulite, Clear, .75" width rid 1.12 0.95 0.98 0.65 0.64 0.66 0.67 Sin le Glaze, One Lite, Clear 1.12 0.95 0.98 0.72 0.70 0.74 0.75 3/4 IG, Simulite, Clear, 1.5' width grid 0.49 0.49 0.49 0.53 0.49 0.54 0.53 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.49 0.49 0.58 0.55 0.60 0.60 3/4" IG, One Lite, Clear 0.49 0.49 0.49 0.64 0.61 0.67 0.67 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.36 0.35 0.29 0.29 0.47 0.47 3/4 IG, Simulite, Low E", .75" width grid 0.30 0.36 0.35 0.32 0.32 0.53 0.53 3/4" IG, One Lite Low E' 0.30 0.36 0.35 0.35 0.35 0.59 0.59 CLAD SLIDING PATIO DOOR UNITS AA (Res)- 72 x 82 BB (NRes) - 72 x 96 Single Glaze, Simulite Clear, 1.5' width grid 1.11 0.91 0.92 0.49 0.48 0.48 0.48 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.91 0.92 0.53 0.52 0.52 0.53 Single Glaze, One Lite, Clear 'W 1.11 0.91 0.92 0.57 0.56 0.57 0.57 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.49 0.50 0.44 0.42 0.43 0.43 3/4 IG, Simulite, Clear, .75' width grid 0.49 0.49 0.50 0.48 0.45 0.47 0.47 3/4" IG, One Lite, Clear 0.49 0.49 0.50 0.51 0.48 0.51 0.51 3/4 IG, Simulite, Low E", 1.5" width grid 0.30 0.37 1 0.37 0.25 0.25 0.38 0.38 3/4 IG, Simulite, Low E", .75" width grid 0.30 0.37 0.37 0.27 0.27 0.42 0.41 3/4" IG, One Lite, Low E' 0.30 0.37 0.37 0.29 0.28 0.45 0.45 CLAD DOOR TRAMSOM UNITS AA (Res) 16 x 82 BB (NRes) -16 x 82 Single Glaze, Simulite, Clear, 1.5' width grid 1.11 0.82 0.87 0.26 0.15 0.20 0.09 Single Glaze, Simulite, Clear, .75" width rid 1.11 0.82 0.87 0.32 0.29 0.28 0.25 Single Glaze, One Lite, Clear 1.11 0.82 0.87 0.39 0.43 0.35 0.42 3/4 IG, Simulite, Clear, 1.5" width rid 0.49 0.53 0.53 0.24 0.14 0.18 0.08 3/4 IG, Simulite, Clear, .75" width rid 0.49 0.53 0.53 0.29 0.26 0.25 0.22 3/4" IG, One Lite, Clear 0.49 0.53 0.53 0.35 0.38 0.32 0.37 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.46 0.46 0.16 0.1-1-1 0.16 0.07 3/4 IG, Simulite, Low E", .75" width grid 0.30 0.46 0.46 0.18 0.17 0.22 0.20 3/4" IG, One Lite, Low E' 0.30 0.46 0.46 0.22 0.23 1 0.28 0.33 CLAD DOOR SIDELITE UNITS AA (Res) -16 x 82 BB (NRes) -16 x 82 0 0 F, a L L 0 Single Glaze, Simulite Clear, 1.5" width grid 1.11 0.70 0.21 0.20 0.15 0.15 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.70 0.25 0.24 0.19 0.19 Single Glaze, One Lite, Clear 1.11 0.70 0.29 0.28 0.24 0.24 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.50 0.19 0.18 0.14 0.13 3/4 IG, Simulite Clear, .75" width grid 0.49 0.50 0.23 0.21 0.18 0.17 3/4" IG, One Lite, Clear 0.49 0.50 0.26 0.25 0.22 0.21 3/4 IG, Simulite, Low E', 1.5" width grid 0.30 0.45 0.13 0.13 0.12 0.12 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.45 0.15 0.15 0.16 0.15 3/4" IG, One Lite Low E' 0.30 0.45 0.17 0.17 0.19 0.19 DOOR CLAD INSWING AND RADIUS TOP INSWING AA (Res)- 38 x 82 BB (NRes) - 38 x 82 Sin le Glaze, Simulite, Clear, 1.5" width grid 1.11 0.85 0.44 0.42 0.42 0.42 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.85 0.49 0.46 0.48 0.47 Single Glaze, One Lite, Clear 1.11 0.85 0.54 0.51 0.54 0.53 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.46 0.39 0.36 0.38 0.37 3/4 IG, Simulite, Clear, .75' width grid 0.49 0.46 0.43 0.40 0.43 0.42 3/4" IG, One Lite, Clear 0.49 0.46 0.48 0.44 0.48 0.47 3/4 16, Simulite, Low E', 1.5" width grid 0.30 0.35 0.23 0.22 0.34 0.33 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.35 0.25 0.24 0.38 0.37 3/4" IG, One Lite, Low E' 0.30 0.35 0.27 0.26 0.43 0.41 CLAD INSWING SIDELITE UNITS AA (Res) -16 x 82 BB (NRes) -16 x 82 Sin le Glaze, Simulite, Clear, 1.5" width grid 1.11 0.64 0.20 0.19 0.15 0.15 Single' Glaze, Simulite, Clear, .75" width grid 1.11 0.64 0.24 0.23 0.19 0.19 Single Glaze, One Lite, Clear 1.11 0.64 0.28 0.27 0.24 0.23 3/4 IG, Simulite, Clear, 1.5 width grid 0.49 0.43 0.18 0.17 0.14 0.13 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.43 0.21 0.20 0.17 0.17 3/4" IG, One Lite, Clear 0.49 0.43 0.25 0.23 0.22 0.21 3/4 IG, Simulite, Low E`, 1.5 width grid 0.30 0.38 0.12 0.12 0.12 0.12 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.38 0.14 0.14 0.15 0.15 3/4" I,lG, One Lite, Low E' 0.30 0.38 0.16 0.15 0.19 0.18 CLAD OUTSWING DOOR UNITS AA (Res)- 38 x 82 BB (NRes) - 38 x 82 Single Glaze, Simulite, Clear, 1.5" width gdd 1.11 0.90 0.45 0.43 0.43 0.42 Single Glaze, Simulite, Clear, .75" width gdd 1.11 0.90 0.50 0.48 0.48 0.47 Single Glaze, One Lite, Clear 1.11 0.90 0.55 0.52 0.54 0.53 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.51 0.40 0.37 0.39 0.37 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.51 0.45 0.41 0.44 0.42 3/4" IG, One Lite, Clear 0.49 0.51 0.49 0.46 0.49 0.47 3/4 IG, Simulite, Low E', 1.5" width gdd 0.30 0.40 0.24 0.23 0.34 0.33 3/4 IG, Simulite, Low E', .75" width gid 0.30 0.40 0.26 0.25 0.39 0.37 3/4" IG, One Lite, Low E' 0.30 0.40 0.28 0.27 0.43 0.42 CLAD OUTSWING SIDELITE UNITS AA (Res) -16 x 82 BB (NRes) -16 x 82 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 0.73 0.22 0.21 0.16 0.16 Single Glaze, Simulite, Clear, .75" width gdd 1.11 0.73 0.26 0.25 0.20 0.20 Single Glaze, One Lite, Clear 1.11 0.73 0.30 0.29 0.25 0.25 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.52 0.20 0.19 0.14 0.14 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.52 0.24 0.22 0.18 0.18 3/4" IG, One Lite, Clear 0.49 0.52 0.27 0.26 0.23 0.22 3/4 IG, Simulite, Low E', 1.5 width grid 0.30 0.47 0.14 0.14 0.13 0.12 3/4 IG, Simulite, Low E', .75" width grid 0.30 0.47 0.16 0.15 0.16 0.16 3/4" IG, One Lite, Low E' 0.30 0.47 0.18 0.17 0.20 0.19 CLAD SWING DOOR TRANSOM AA (Res)- 38 x 14 BB (NRes) -74 x 14 Single Glaze, Simulite, Clear, 1.5" width grid 1.11 0.84 0.89 0.36 0.40 0.31 0.37 Single Glaze, Simulite, Clear, .75" width grid 1.11 0.84 0.89 0.38 0.42 0.33 0.39 Single Glaze, One Lite, Clear 1.11 0.84 0.89 0.40 0.43 0.35 0.41 3/4 IG, Simulite, Clear, 1.5" width grid 0.49 0.56 0.56 0.33 0.35 0.28 0.33 3/4 IG, Simulite, Clear, .75" width grid 0.49 0.56 0.56 0.34 0.37 0.30 0.35 3/4" 1G One Lite, Clear 1 0.49 0.56 0.56 0.36 0.38 0.32 0.37 0 . . - AW . 60 . . loo 0 s 9 0 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE W H I T E Main House 8/10/04 YSTEM NAME FLOOR AREA ZONE 1 (Kitchen/Living) 1,717 Number of Systems 1Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 51.8 Cooling System Output per System 57,800 Total Output (Btuh) 57,800 Total Output (Tons)Total 0 Output (Btuh/sgft)Total Output (sgft/Ton) 356.5 Air System CFM per System 2,250 Airflow (cfm) 2,250 Airflow (cfm/sgft) 1.31 Airflow (cfm/Ton) 467.1 Outside Air (%)0.0 side Air (cfm/sgft) 0.00 Ealues above given at ARI conditions 24.0 °F 69.3 °F 69.3 °F Outside Air0 cfr 69.3 OF 114.1 /80.3OF Outside t 0 cfm 78.8 / 63.4 OF COIL COOLING PEAK COIL HTG. PEAK CFM Sensible I ---ent CFM Sensible Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD -IVAC EQUIPMENT SELEC 44,433 7,222 BDP 597CN060-F / CK5A (2250 cfm) 45,382 4,116 89,000 Total Adjusted System Output 45,382 4,116(Adjusted for Peak Design Conditions)TIME OF SYSTEM PEAK Aug 2 pm Jan 12 amDam emDera ures a ime O ea Ing ea 105.0 of Supply Fan Heating Coil 2250 cfm S. Return Air Ducts V 78.8/63.4 OF 78.8/63.4 OF = 55.0/53.6 OF EnergyPro 3.1 By EnergySoft Supply Fan 2250 cfm User Number. 1086 Cooling Coil Return Air Ducts Job Number. 0418.00 Supply Air Ducts 104.3 of ROOMS 70.0 of I Supply Air Ducts 55.8 / 53.9 of 437% R.H. ROOMS 78.0 / 63.1 OF Page:t of 3 40,394 7,222 964 36,423 0 2,020 1,820 0 0 0 00 0 0 2,020 1,821 44,433 7,222 BDP 597CN060-F / CK5A (2250 cfm) 45,382 4,116 89,000 Total Adjusted System Output 45,382 4,116(Adjusted for Peak Design Conditions)TIME OF SYSTEM PEAK Aug 2 pm Jan 12 amDam emDera ures a ime O ea Ing ea 105.0 of Supply Fan Heating Coil 2250 cfm S. Return Air Ducts V 78.8/63.4 OF 78.8/63.4 OF = 55.0/53.6 OF EnergyPro 3.1 By EnergySoft Supply Fan 2250 cfm User Number. 1086 Cooling Coil Return Air Ducts Job Number. 0418.00 Supply Air Ducts 104.3 of ROOMS 70.0 of I Supply Air Ducts 55.8 / 53.9 of 437% R.H. ROOMS 78.0 / 63.1 OF Page:t of 3 0 ROOM LOAD SUMMARY PROJECT NAME DATE WHITE Main House 8/10/04 OYSTEM NAME FLOOR AREA ZONE 1 (Kitchen/Living) 1,717 • 0 0 0 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE '-ATENT CFM SENSIBLE ZONE 1 ONLY ice v ng 1 1,627 40,394 7,222 1,627 40,394 7,222 964 36,423 PAGE TOTAL 1,627 40,394 7,222 964 36,423 \ TOTAL 1,627 40,394 7,222 964 36,423 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:1 of 3 • ROOM HEATING PEAK LOADS Project Title Date H I T E Main House 8/10/04 Room Information Design Conditions Room Name IGtcheNLiving Time of Peak Jan 12 am Floor Area 1,717 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Arpa It_Vahro Ar OC Rfu/hr • C/11-2 (R.38.2x_.16) 917.5 X 0.0257 x 46.0 = 1,087 SolaTube (Default) Skylite 2.5 X 0.6800 x 46.0 = 77 C/R-3 (R.38.2x .16 365.0 x 0.0295 X 46.0 = 496 'R-0 Floor (F.0.2x .16) 456.0 x 0.2535 x 0.0 = 0 Interior Air Wall 83.0 x 1.1765 x 0.0 = 0 W-1 Wall .21.2x6.16) 841.3 x 0.0566 x 46.0 = 2,191 Sierra Pacific Mtl. Clad 380.7 x 0.5100 x 46.0 = 8,930 W-2 Wall (W.21.2x6.16) 205.0 x 0.0572 x 46.0 = 540 Double Tinted Default NM 45.0 x 0.9600 X 46.0 = 1,987 Solid Wood Door 24.0 x 0.3872 x = 427 Slab -0n -Grade perimeter =138.9 X x 45.5 = 6,320 x x = • x x = x x = x x = x x = x x = x x = • x x - x x = x x = x x = x x = x x = • x x = x x = x x = x x = x x = x x = • xx x x - - x x = x x = x x = x x = x x = • x x = x x = Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: 22,055 Infiltration:x 1.080 x 1,717 x LUIY. 10.1 x 1.00 / 60] x ® = 14,367 r nsi a Area a ng Height AT Fraction •� TOTAL HOURLY HEAT LOSS FOR ROOM 36,423 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number: 0418.00 Page:1 of 4 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY W H I T E Main House 8/10/04 Protect Title Date • Room Name Kitchen/Living Design Indoor Dry Bulb Temperature: 78°F Design Outdoor Dry Bulb Temperature: 115°F Design Temperature Difference: 37°F • Conduction /R-2 (R.38.2x_ 16) olaTube (Default) Skylite /R-3 (R.38.2x_.16) R-0 Floor (F.0.2x .16) Interior Air Wall 1-1 Wall (W.21.2x6.16) ierra Pacific Mtl. Clad -2 Wall (W.21.2x6.16) 10-1 Tinted Default NM Area 917 841 X X X X X X X x X U -Value 0.0 o.E OA 0.2 1.1 0.0 0.5 0.0 nu X X X X X X X x x DETD 1 = = = = = = = = = Btu/hr 56.0 1,323 37.0 62 56.0 604 0.0 0 0.0 0 35.6 1,696 37.0 7,183 35.6 418 37.0 1,598 1. Design Equivalent Temperature Difference (DETD) Page Total 12,884 Items shown with an asterisk (') denote conduction through an Interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 00 Skylight (Skylight) FxdMtlCld K (Northwest) FxdMtlCld (BB) (Northwest) FrDr (6) (Northwest) FxdMtlCld (A) (Northeast) FrontDr (1) (Southeast) FxdMtlCld (B) (Southeast) FxdMtlCld (C) (Southeast) FxdMtlCld (L) (Southwest) FxdMtlCld (M) (Southwest) ( 0.0 x x x x X X x x X x 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 2.5 X x X X x x X x x X X X X 0.632 = = = = = = = = _ = 235 (-0.0 48.0 -152)X 48) 0.609 1,404 ( 0.0 12.0 -48)x -48)X 0.609 351 ( 0.0 144.0 0.460 3,178 ( 0.0 30.0 48)X 0.609 877 (-45.0 0.0 62) 0.609 411 ( 0.0 20.0 -62)X 0.609 755 20.0 62)X 0.609 755 F0.00.0 48.0 6)X0.609 1,813 26.7 62) 0.609 1,007 • Sched. Pzge Total 10,767 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,717 x 0.500 Watts/sgft x 3.41 Btuh/Watt = 2,930 Occupants 1.00 X 1,717 x 255 Btuh/occ. / 333 sgf0focc. = 1,315 Receptacle 1.00 X 1,717 X O.000 Watts/sqft x 3.413 Btu iMatt = 0 Process 1.00 x 1,717 x 0.000 Watts/sqft x 3.413 Btu VWatt = 0 • Infiltration: 1.00 x 1.080 x 1,717 x 10.11 x 1.00 / 60] 37 = 11 556 c u eAir Sensitite, Area Ceiling Heignt Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40,394 Sched. ` Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,717 X 225 Btuh/ocC. / 333 sgft/occ. Receptacle 1.00 X 1,717 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 1,717 x 0.000 Wafts/sgft x 3.41 Btuh/VVatt = o Infiltration: 1.00 x g401 x 1,71 x 10.1 x 1.00 / 60] 1 O.Om433 --bcneauie Air Latent Ceiling Reignt�yyl Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7,222 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:1 of 6 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY W H I T E Main House 8/10/04 Project Title Date 0 Room Name 40 0 Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Kitchen/Living 780F 1150F Conduction Area U -Value C ETD' �o id Wood Door 1 0.38721 370F Btu/hr 331 1. Design Equivalent Temperature Difference (DETD) PE ge Total 331 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdMtlCld (CC) (Southwest) ( 0.0 x 1 + 12.0 X 62)x 0.609 = 453 FrDr 8 (Southwest) ( 20.0 X 1 + 0.0 x 62)x 0.460 = 138 ( x + x )x = ( x + x )} ( X + X )x ( x + x ) }. ( x + X )}. ( x + X )x ( x + ( x + x )}: Sched. Page Total 591 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,717 x 0.500 Watts/sgft x 3.41 Btuh/Waft = 2,930 Occupants 1.00 X 1,717 X 255 Btuh/occ. / 333 sgft/occ. = 1,315 Receptacle 1.00 x 1,717 x 0.000 Watts/sqft X 3.413 Btuh/VVatt = 0 Process 1.00 x 1,717 x 0.000 Watts/sgft x 3.41 BtuhfWatt = 0 • Infiltration: 1.00 x E1.080 x 1,717 x10.11 x 1.00 60] 37 = 11,556 ceue v ns a rea a inHeightp Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40,394 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1,717 x 225 Btuh/occ. /F 333 sgfJocc. Receptacle 1.00 x 1,717 x 0.000 Watts/sgft x 1 3.411 Btutt/Watt = 0 Process 1.00 x 1,717 x 0.000 Watts/sqft x 1 3.41 Btdh/Watt = 0 Infiltration:1.00 x 4,840 x 1,71 x 10.1 x 1.00 / 60] L.eue,062 it en rea a ng e g Qyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7,222 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number: 0418.00 Page:2 of 8 • 0 IN 0 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE W H I T E Main House 8/10/04 YSTEM NAME FLOOR AREA ZONE 2 (Living/Guest Loft) 1,220 NGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sqft) 29.5 Cooling System Output per System 35,300 Total Output (Btuh) 35,300 Total Output (Tons) 2.9 Total Output (Btuh/sqft) 28.9 Total Output (sgft/Ton) 414.7 Air System CFM per System 1,350 Airflow (cfm) 1,350 Airflow (cfm/sgft) 1.11 Airflow (cfmrTon) 458.9 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 1COILHTG.PEAK CFM Sensible Latent CFM Sensible 997 24,768 5,362 550 20,778 0 1,238 1,039 0 0 0 0 0 0 0 0 0 1,238 1,039 27,244 5,362 22,856 BDP 597CN036-F / CK5A (1350 cfm) 28,072 2,287 36,000 Total Adjusted System Output 28,072 2,267 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am earn I empera ures —at Time of Heating ea 24.0 OF 69.3 of 69.3 OF 105.0 OF Outside Air 0 cfm 69.3 OF 114.1 / 80.3 of Outside Ai 0 cfm •(( 1178.8/63.7 of 0 Supply Fan Heating Coil 1350 cfm i,, Return Air Ducts V 78.8163.7 of 78.8/63.70F m 55.0 / 53.6 of Supply Air Ducts 104.3 of ROOMS 70.0 of I 11f Supply Air Ducts Supply Fan Cooling Coil 55.8 / 53.9 of 1350 cfm 4416% R.H. ROOMS 78.0 / 63.4 OF EnergyPro 3.1 By EnergySoft User Number. 1086 Return Air Ducts Job Number. 0418.00 Page:2 of 3 0 40 • 0 6_ 4 ROOM LOAD SUMMARY W H I T E Main House 8/10/04 ZONE 2 (Living/Guest Loft) 1 1,220 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Area iving rea 1 542 13,447 3,374 542 13,447 3,374 308 11,633 Guest Loft GuestLoft 1 456 11,320 1,988 456 11,320 1,988 242 9,145 PAGE TOTAL 997 24,768 5,362 550 20,778 TOTAL 997 24,768 5,362 550 20,778 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Pagel of 3 0 ROOM HEATING PEAK LOADS Project Title Date N H I T E Main House 8/10/04 oom Information Design Conditions Room Name living Area Time of Peak Jan 12 am Floor Area 647 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr • C/11-3 (R.38.2x_A6) surface 540.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0295 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 734 W-1 Wall (W.21.2x6.16) 134.0 0.0566 46.0 349 Sierra Pacific Mtl. Clad 120.0 0.5100 46.0 2,815 Slab -0n -Grade pedmeter=17.0 45.5 774 r _ i Items shown with an asterisk (') denote conduction through an interior Infiltration:1.00 x 1.080 x c e u e r ens a Fraction to another room. 647 x 13.00 rea Ceiling Height —1.00 1601 Page Total: pT 4,672 1 .TOTAL HOURLY HEAT LOSS FOR ROOM 11,633 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0418.00 Page:2 of 4 L • I ROOM HEATING PEAK. LOADS Project Title H I T E Main House 0/04 Room Information Design Conditions Room Name Guest Ldt Time of Peak Jan 12 am Floor Area 573 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70 OF Conduction Area 573.0 839.0 106.0 o1 0.0257 x 46.0 0.0566 x 46.0 0.5100 X 46.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Btu/hr 679 2,185 2,487 xx X X = Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 5,351 Infiltration: 1.00 x 1.080 x 573 x 8.00 x c e u Air Sensible Area 1.00 /60 x i ng e g t Fraction AT' �( TOTAL HOURLY HEAT LOSS FOR ROOM 9,145 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number: 0418.00 Page:3 of 4 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY 0 0 .O W H I T E Main House 8/10/04 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 780F 115°F 370E Conduction Area U -Value DETD 1 Btu/hr X 56.0 = 893 X 35.6 = 270 X 37.0 = 2,264 X = X = X = X = X - X = 1. Design Equivalent Temperature Difference (DETD) hace9 Page Total 3 428 Items shown with an asterisk (*) denote conduction thrQt� tided interior surfacled other room. ' Su Uns Solar Gain Orientation Area ( 0.0 ( 0.0 ( 0.0 ( 0.0 ( ( ( ( ( ( x1 x x x x x x x X X SGF + + + + + + + + + + Area x x x x x X X X X x SGF )x )x )x )X )X )X SC = = = = = = = = = = Btu/hr FxdMtlCld (Z) ' (Northwest) 12.0 48)x - 0.609 351 FxdMtlCld AA (Northwest) 1 12.0 48)x 0.609 351 FrDr (5) (Northwest) 1 48.0 48)x 0.460 1,059 FrDr (4) (Northwest) 1 48.0 48)x 0.460 1,059 Sched. Page Total 2,s2o Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 647 X 0.500 Watts/sgft x 3.411 BtuhfWatt — 1,104 Occupants 1.00 X 647 X 255 Btuh/occ. / 333 sgftrocc. = 495 Receptacle 1.00 X 647 X 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 647 x 0.000 Watts/sgft x 3.413 BtuhNVatt = 0 • Infiltration: 1.00 x 1.080 x 647 x 13.00 x 1.00 60] 37 = 5,599 eeueAir Sensitile Area Ceiling Relgrif Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,47 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 647 x 225 Btuh/occ. / 333 sgfUocc. = 437 Receptacle ::: 1.00 x 647 x 0.000 Watts/sqft x 3.41 Btu -t/Watt = 0 Process 1.00 x 647 x 0.000 Watts/sgft x 3.41 Btu !/Watt = 0 Infiltration: 1.00 x 4,840 x x 813.00 x 1.00 X 60] Q00)433 = 2,937 eeue e �J Fraction ita enrea Ceiling � TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,374 EnergyPro 3.1 By Ener Soft User Number. 1088 Job Number. 0418.00 Page:3 of 6 41 11 RESIDENTIAL ROOM COOLING LOAD SUMMARY W H I T E Main House 8/10/04 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction /R-2 (R.38.2x_.16) -1 Wall (W.21.2x6.16) Terra Pacific MI. Clad Area U -Value Guest Loft 78°F 1150F 370F X X X X X X X X X DETD 1 = = = = = = - = = Btu/hr 56.0 826 35.6 1,691 37.0 2,000 FxdMtlCld (FF) (Northwest) FxdMtlCld (V) (Northeast) FxdMtlCld (T) (Southeast) FxdMtlCld (U) (Southeast) FxdMtlCld (GG) I (Southeast) ( 0.0 1.0 1. Design Equivalent Temperature Difference (DETD) hh Page Total 4,518 Items shown with an asterisk (*) denote conduction thr��t acted interior st�rfnsh t: another room. . Solar Gain Orientation Area SGF Area SGF SC Btu/hr 40 0 FxdMtlCld (W) (Northwest) FxdMtlCld (Northwest) FxdMtlCld (1/) (Northwest) FxdMtlCld (DD) (Northwest) FxdMtlCld (EE) (Northwest) FxdMtlCld (FF) (Northwest) FxdMtlCld (V) (Northeast) FxdMtlCld (T) (Southeast) FxdMtlCld (U) (Southeast) FxdMtlCld (GG) I (Southeast) Internal Gain ( 0.0 x1 X x x X x x x x x + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1.0 X x X x X X x X x X 48) X X X X ) X 0.609 = = = = = = = = = 29 ( 0.0 1.0 48) 0.609 29 ( 0.0 1.0 -48)X 0.609 29 ( 0.0 1.0 -48)X 0.609 29 ( 0.0 1.0 -48)x 0.609 29 ( 0.0 1.0 -48)X 0.609 29 ( 0.0 16.0 48) 0.609 468 ( 0.0 10.0 62)X 0.609 378 ( 0.0 16.0 6) 0.609 (1-0.0 10.01 62 0.609 378 Sched. Page Total Frac. Area Heat Gain Lights. 1.00 X 573 X 0.500 Wafts/sgft x 3.41 3BtuhMatt Occupants 1.00 X 573 x 255 Btuh/occ. I 333 sgft'occ. Receptacle 1.00 X 573 X 0.00o Wafts/sgft x 3.41 Btuh/Waft Process 1.00 x 573 x 0.000 Wafts/sgft x 3.41 BtuhMatt x 1 1.080 x 573 x x 1.00 /601 �e;iirtgeightle it ensible rea o Infi 2,003 Btu/hr 978 439 = 0 0 3 052 ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11 320 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 573 x 225 Btuh/occ./ 33 sgfllocc. = 387 Receptacle 1.00 x 573 X 0.000 Wafts/sgft x 3.41 Btu!/Waft = o Process 1.00 x 573 X 0.000 Wafts/sgft x 3.41 Btu /Waft = 0 Infiltration: 1.00 x 4,840 x 57 x 8.00 x 1.00 /60 0.0)433 c u e Air Latent Area tening neignt AUH &W .� Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,988 EnergyPro 3.1 By Ener Soft User Number. 1086 Job Number. 0418.00 Page:4 of 8 41 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY S 0 16 00 W H I T E Main House 8/10/04 Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X Date 7m Guest Loft 780F 115°F 37°F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total 0 Items shown with an asterisk (*) denote conduction thrg�tahedn interior dd st�rfnshacped other room. Solar Gain Orientation Area SGF Area SGF SC. Btu/hr FrDr (40) (Southeast) ( 48.0 x 1 + 0.0 X 62)x 0.460 = 331 ( x + x )x ( x + X )X ( x + X )X ( x + X )X ( x + x )X. ( x + x )x = ( x + x )x; _ ( x + x )x = ( x + x )x = Sched. Page Total 331 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 573 X 0.500 Watts/sqft x 3.411 BtuhMaft = 978 Occupants 1.00 X 573 X 255 Btuh/OCC. / 333 sgft;occ. = 439 Receptacle 1.00 x 573 X 0.000 Watts/sgft x 3.413 Btuh/Waft = 0 Process 1.00 x 573 x 0.000 Wafts/sgft x 3.412 Btui/Watt = 0 • Infiltration: 1.00 x 1.080 x 573 x 8.00 x 1.00 / 60] 37 = 3,052 L. r Sensme, rea Celling e g p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,320 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants1.00 x 573 x 225 Btuh/occ. / 333 sgft'occ. = 387 Receptacle 1.00 x 573 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Process 1.00 x 573 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = 0 Infiltration: 1.00 x 4,Wj X 57 x 8.00 x 1.00 / 60] 0.08433 ceue Air Latent Area ceiiing neigntpyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,988 EnergyPro 3.1 By Ener Soft User Number. 1086 Job Number. 0418.00 Page:5 of 6 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE W H I T E Main House 8/10/04 STEM NAME FLOOR AREA ZONE 3 (Master Bed) 868 Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sgft) 41.5 Cooling System Output per System 29,000 Total Output (Btuh) 29,000 Total Output (Tons) 2.4 Total Output (Btuh/sgft) 33.4 Total Output (sqftrron) 359.2 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 1.15 Airflow (cfmrron) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 24.0 of 69.2 of 69.2 of Outside Air Q 0 cfm 69.2 OF 14.1 / 80.3 of Outside Ai 0 cfm 78.8163.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Laent CFM Sensible Total Adjusted System Output (Adjusted for Peak Design Conditions) 21,70 3,179 708 17,578 3,557 455 17,178 0 879 859 0 0 0 0 0 0 0 0 0 879 859 19,336 3,557 18,896 BDP 597CN030-F / CK5A (1000 cfm) 21,701 3,179 Total Adjusted System Output (Adjusted for Peak Design Conditions) 21,70 3,179 36,000 36,000 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am naera ures at I ime ot Heatina Peaki 105.0 OF Supply Fan Heating Coil 1000 cfm k Return Air Ducts 14 78.8/63.5 OF 78.8/63.50F = 55.0/53.60F Supply Fan Cooling Coil 1000 cfm EnergyPro 3.1 By EnergySoft User Number. 1086 Return Air Ducts Job Number. 0418.00 Supply Air Ducts 104.2 of ROOMS 70.0 of I Supply Air Ducts 55.8 / 53.9 of 44.1% R.H. ROOMS 78.0 63.2 of I Page:3 of 3 0 46 a a 0 6 ROOM LOAD SUMMARY PROJECT NAME W H I T E Main House DATE 8/10/04 /JYSTEM NAME ZONE 3 (Master Bed) FLOOR AREA 868 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING TEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE -1TENT CFM SENSIBLE ZONE 3 ONLY Master Esed 1 708 17,578 3,557 708 17,578 3,557 455 17,178 PAGE TOTAL 17081 17,5781 3,557 455 17,178 l TOTAL 708 17,578 3,557 455 17,178 EnergyPro 3.1 By EnergySoft User Number. 1088 Job Number. 0418.00 Page:3 of 3 F, ROOM HEATING PEAK LOADS Project Title Date H I T E Main House 8/10/04 71 ` Room Information Design Conditions Room Name Master Bed Time of Pea17 Jan 12 am Floor Area 868 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70 OF Conduction surface Area Area X x X x X x x x x x x x x x x x x x x x x x x x xx x x x x x x x x x x x x x x 9.80 x e g t U -Value X x x X x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x AT of = = = = = = = = = = = = = = = = = = = = = = = = — — = = = = = = = = = = = = = Btu/hr C/R-2 (R.38.2x_.16) 866.8 0.0257 46.0 1,027 SolaTube (Default) Skylite 1.2 0.6800 46.0 39 W-1 Wall .21.2x6.16 608.0 0.0566 46.0 1,584 Sierra Pacific Mtl. Clad 123.0 0.5100 46.0 2,886 Double Tinted Default N 12.5 0.7700 46.0 443 Sierra Pacific Mtl. Clad 12.5 0.4900 46.0 282 • W-2 Wall .21.2x6.16 30.0 0.0572 46.0 79 Slab -0n -Grade perlineter=83.5 45.5 3,799 ' Items shown with an asterisk (') denote conduction through an interior Infiltration: 1.00 x 1.080 x e u e r Sensible Fraction to another room. 868 x E a ing 1.00 /6] J Page Total: ® pT 10,138 TOTAL HOURLY HEAT LOSS FOR ROOM 17,178HOURLY HEAT LOSS FOR ROOM 17,178 EnergyPro 3.1 By EnergySoft User Number. 1086 Job Number. 0418.00 Page:4 of 4 0 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY W H I T E Main House 8/10/04 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value DETD 1 lC R-2 (R.38.2x.16) laTube (Default) Skylite -1 Wall (W.21.2x6.16) erra Pacific W. Clad uble Tinted Default (NW) Terra Pacific MI. Clad -2 Wall (W.21.2x6.16) 0.0257 0.6800 0.0566 0.5100 0.7700 0.4900 X 56.0 X 37.0 X 35.6 X 37.0 X 37.0 X 37.0 X 35.6 X X Master Bed 78°F 115°F 370E Btu/hr 1,250 31 1,226 2,321 356 227 61 1. Design Equivalent Temperature Difference (DETD) Page Total 5,472 Items shown with an asterisk (") denote conduction thruahd adn interior surface ac� another room. 41 Solar Gain Orientation Area SGF Area SGF SC Btu/hr .0 Skylight (Skylight) FxdMtlCld I (Northwest) FxdMtlCld (J) (Northwest) FrDr (3) (Northwest) DbMngAlum (D) (Northeast) FxdMtlCld (E) (Northeast) DbIHng1V1t1C1d (F) (Northeast) FxdMtlCld (G) (Northeast) FxdMtlCld (H) (Northeast) ( 0.0 x x x x X X x X x X 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + + 1.2 X x x x X x x x x x 152) x X x x x ) x )}_ 0.63 = = = = = = = = __ _ 120 (-0.0 24.0 48) 0.609 702 ( 0.0 24.0 48) 0.609 702 ( 0.0 20.0 48) 0.460 441 (-0.0 12.5 48) 0.678 407 ( 0.0 35.0 48)X 0.609 1,023 ( 0.0 12.5 48) 0.529 317 ( 0.0 10.0 48)) 0.609 292 ( 0.0 10.0 0.609 292 ( 1 Sched. Page Total 4,297 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 868 X 0.500 Watts/sqft x 3.41 Btuh/Watt = 1,481 Occupants 1.00 X 868 x 255 Btuh/occ. / 333 sgft/occ. = 665 Receptade 1.00 .X 868 X 0.000 Watts/sqft x 3.413 Btutt/Waft = 0 Process 1.00 x 868 X 0.000 Watts/sqft x 3.412 Btuft/Watt = 0 • Infiltration: 1 1.00 x1.080 x 868 x 9.80 x 1.00 / 60] 37 = 5,663 ceue Air sensitile rea a mg e g Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17,578 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 868 X 225 Btuh/ocC. / 333 sgf`locc. = 586 Receptacle 1.0 0 x 868 x 0.000 Watts/sqft x 3.41 BtulhfWatt = 0 Process 1.00 X 868 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0 Infiltration: 1.00 x 4,840 x 86 x 9.80 x 1.00 / 60] Q0.00433 ceue r Latent i mg rea ee ! Fraction 9(� J`{ TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,557 EnergyPro 3.1 By Ener Soft User Number. 1086 Job Number. 0418.00 Page:6 of 8 0 0 11 qr •0 r GF *0 0