13-1592 (SFD)14
T4'yl 4 Q"
P.O. BOX 1504 VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 5/12/14
Application Number: 13-00001592 Owner:
Property Address: 80559 VIA PESSARO ELLIOTT STEVE & GERR1
APN: 777-160-039- - - 221 COLDWELL AVE
Application description: DWELLING - SINGLE FAMILY DETACHED LOS GATOS 95032 CALIF
Property Zoning: LOW DENSITY RESIDENTIAL LOS GATOS, CA 90532
Application valuation: 738132 (,
L___
Contractor:
Applicant: Architect or Engineer: v 2Q'11� 5JEHA 3408COSSTRRUCTTION, MICHAEL
VIA LA QUINTA, CA 92253
LLAA NTA (925)250-4038
Lic. No.: OOR SQUCEOEIaTLic. No.: 410408
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License CI s: B License No.: 410408
Date: Contractor:
WNER- ILDER DECLARATION
I hereby affirm under penalty of perjury tha am exempt rom the Contractor's State License Law for the
following reason (Sec. 7031.5, Business d Profession -6de: Any city or county that requires a permit to
construct, alter, improve, demolish, or rep In s re, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reawn _..
Date:
Owner:
CONSTRUCTION LENDING AGENCY
1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: [`.
Lender's Address: 1
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I hand will maintain a certificate of consent to self -insure for workers' compensation, as provided
I by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
have and will maintain workers'.compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier T Policy Number EXEMPT
I c rtify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I sh Id become subject tot rkers' compensation provisions of Section
37 0 of the Lab ode, o wit mply wi y those provisions.
Date: O Applicant:
WARNING: FAILURE TO SECURE WORKERS'0 NSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENA S AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose rggyeat and fnr
vftse. henf:fit wnrk it r-fgrmed uotda - puiauant to any pdfrriit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
certify that I have read this application and state that the above information is torr t. I agree to comply with all
city and county ordinances and state laws relating to building co ction, ereb authorize representatives
of this co my enter upon the above -mention roper r spect rposes.
Date: In 1 Signature (Applicant or Agent):
Application Number . . . . . 13-00001592
Permit
. . .
BUILDING 2013
Additional
desc . .
Permit Fee
. . . .
875.27
Plan Check Fee
00
Issue Date
. . . .
Valuation . . .
. 738132
Expiration
Date . .
11/08/14
Qty Unit Charge
Per
Extension
BASE
FEE
573.43
539.00
----------------------------------------------------------------------------
.5600
THOU BLDG
$200,001-$1M
301.84
Permit
. . .
ELECTRICAL 2013
Additional
desc . .
1
Permit Fee
. . . .
275.78
Plan Check Fee
.00
Issue Date
. . . .
Valuation . . . .
0
Expiration
Date
11/08/14
Qty Unit Charge
Per
Extension
.00
23.8300
LS ELEC
FIXTURES, FIRST 20
.00
1.00
23.8300
EA ELEC
SERVICES
23.83
1.00
23.8300
EA ELEC
TEMP POWER POLES
23.83
1.00
143.0000
LS ELEC
NEW RES, FIRST 1 KSF
143.00
7.00
----------------------------------------------------------------------------
12.1600
EA ELEC
NEW RES, ADD'L 1 KSF
85.12
Permit
. . . MECHANICAL 2013
Additional
desc . .
Permit Fee
. . . .
476.70
Plan Check Fee
.00
Issue Date
. . . .
Valuation . . . .
0
Expiration
Date . .
11/08/14
Qty Unit Charge
Per
Extension
5.00
35.7500
EA MECH
FURNACE
178.75
5.00
35.7500
EA MECH
CONDENSER/COMP
178.75
9.00
11.9200
EA MECH
VENT FAN
107.28
1.00
----------------------------------------------------------------------------
11.9200
EA MECH
EXHAUST HOOD
11.92
Permit
. . . PLUMBING 2013
Additional
desc . .
Permit Fee
. . . .
619.83
Plan Check Fee
.00
Issue Date
Valuation . . . .
0
Eupiration
Date
11/00/14
Qty Unit Charge
Per
Extension
40.00
11.9200
EA PLBG
FIXTURE/TRAP
476.80
1.00
11.9200
EA PLBG
BUILDING SEWER
11.92
LQPERMIT
Application Number . . . . . 13-00001592
Permit . . . . . . PLUMBING 2013
Qty Unit Charge Per
Extension
4.00 11.9200 EA PLBG ROOF DRAIN
47.68
3.00 11.9200 EA PLBG WATER HEATER/VENT
35.76
1.00 11.9200 EA PLBG WATER INST/ALT/REP
11.92
1.00 35.7500 LS PLBG GAS SYS, 5+ OUTLETS
35.75
-------------------------7--------------------------------------------------
Special Notes and Comments
NEW SFD @ 7893 SQ. FT. WITH 3433 SQ. FT.
PATIO AND 1939 SQ'. FT. GARAGE. HOME HAS
FIRE SPRINKLERS PER 2010 CRC CODES. THIS
PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK
WALLS,DREIVWAY APPROACH OR SOLOR PANELS
,BBQ, FIRE -PIT WATER FEATURES.
February 3, 2014 9:57:03 AM jjohnson.
--------------------------- ------------------------------------------------
Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES
1345.33
BLDG STDS ADMIN (SB1473)
30.00
DIF COMMUNITY CENTERS -RES
129.00
DIF CIVIC CENTER - RES
942.00
DIF FIRE PROTECTION -RES
433.00
DIF LIBRARIES - RES
344.00
PLAN CHECK, ELECTRICAL
104.63
DIF PARK MAINT FAC - RES
40.00
PLAN CHECK, MECHANICAL
286.00
PLAN CHECK, SFD GRADING
143.00
PLAN CHECK, PLUMBING
593.60
DIF PARKS/REC - RES
2048.00
BLDG PC 200K -1M
1898.93
STRONG MOTION (SMI) - RES
73.81
TUMF: RESIDENTIAL
1837.44
DIF STREET MAINT FAC -RES
116.00
DIF TRANSPORTATION - RES
2842.00
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 2247.58 .00 .00
2247.58
Plan Check Total .00 .00 .00
.00
Other Fee Total 13206.74 1200.00 .00
12006.74
Grand Total 15454.32 1200.00 .00
14254.32
LQPERA1IT
Building
LL/DTT- ST.
(&4444"
P.O. BOX 1504
78-495 CALLE TAMPICO
C'A/1n LA QUINTA, CALIFORNIA 92253
Address
City Zip Tel.
I n c /T 11T/f C 42 —n 3 2 1
Address
City Izip
State Lic. City I
& Classif. I Lic. #
Designer
Address Tel. ( 74 O) 77 3_ 4 6DS
Lic. #C'_a
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than rive hundred dollars ($500).
O I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars (5100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT. If, alter making this Certificate of Exemption you should become
subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
a�
APPLICATION ONLY
BUILDING: TYPE CONST. OCC. GRP.
A.P. Number (`
Legal Description L✓oT 30� �30.� r�'ACT�yyy-�
Project DescriptionI�(,��HU' U S
ZONE: BY:
Minimum Setback Distances:
Front Setback fron Center Line
Rear Setback from: Rear Prop. Line
Side Street Setback from Center Line
Side Setback fron Property Line
FINAL DATE INSPECTOR
Issued by:
Validated by:
Validation:
Date Permit
YELLOW = APPLICANT PINK = FINANCE
Sq. Ft.
Size
No.
Stories
No. DIN. /
Units
Newx Add ❑
Alter ❑
Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
AMOUNT
Plan Chk. Dep.
�p
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
M•`_ '.
Infrastructure
ITY OF LA QUINTA
PINAMCF:
TOTAL
Cep
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback fron Center Line
Rear Setback from: Rear Prop. Line
Side Street Setback from Center Line
Side Setback fron Property Line
FINAL DATE INSPECTOR
Issued by:
Validated by:
Validation:
Date Permit
YELLOW = APPLICANT PINK = FINANCE
CERTIFICATE OF COMPLIANCE 4��o
Desert Sands Unified School District
,-; ; 9! 7
47950 Dune Palms Road Q BERMUDA DUNES co
RANCHO MIRAGE 0
Date 12/12/14 La Quinta, CA 92253 INDIAN WELLS
P
No. 31654 (760) 771-8515 v> L INDIO A y
%QIN0 y�
0
Owner Elliott
APN # 777-163-039
Address
Jurisdiction La Quinta
City Zip
Permit #
Tract #
No. of Units 1
Type New Residential Addition
Lot # No. Street
S.F.
Lot # No. Street S.F.
Unit 1 80559 Via Pessaro
107 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/wa Ikways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating o: sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the fol owing reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.36 X 107 S.F. or $359.52 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed projec-_ may now be issued.
Fees Paid By CC/California Bank - Arlene Hinsley Check No. 438137
Bank Name/Recipient of Certificate Telephone 760-773-6605
Funding Residential
BY Dr. Gary Rutherford
Suoerintendent
Fee collected 4/exemptedby SIYar n it rey Payment Recd �t3.G0
$359.52 wer/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this wfrvetoy youthat the 90 -day approval period .n which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) beh alf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
Project Name: Hideaway
Owner's Name: Elliott, Steve & Gerri
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MTIGATION AMOUNT:
COMM/MD. AMOUNT:
DATE:
RECEIPT:
C13ECK k:
MITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Address: 80-559 Via Passaro, LaQuinta
Project Description: New Single Family Dwelling
APN: 772-500-056 1(Od^ Tract #:
Type of Development: Residential XX
Commercial
Total Square Feet of Building Area: 7,893
Date: May 5, 2014
Phone No.
Lot #'s:
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is corrmt and makes this statement under
penalty of perjury and further represents that he/she is authorized to sin on behalf of the owner/deveoper.
Dated: May 5, 2014
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCI
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code Project
65995 Approval
7893
$3.20
$25257.60
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
T HAVE BEEN OR WILL BE SATISFIED IN
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Note:
Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt frow- developer fees. Any mobile
homes being relocated within the same school district's
jurisdiction are exempt from developer fees.
Certificate issued by: Laurie Howard, Secretary Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payme-it of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days start; on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
M V:c/nrycloes/devfees/certificate of compliance form updated 3-2007 11/2010
i
t ,
Southland Title Corporation
RECORDING REQUESTED BY:
AOUTHLAND TITLE (Title)
AND WHEh•RECORDED MAIL. THIS DOCUMENT AND
TAX STATEMENTS TO:
Steven Elliott and Gem Elliott
20331 No. E 61st Court
Redmond, WA 98053
Order No.: 68621507
Escrow No.: PD13909-CY
A:P.N.: 777-160-021
jYZ cL. vZ c�- i coo
DOC # 2008-0527581
09/29/2008 08:00p Fee:15.00
Page 1 of 3 Doc T Tax Paid
Recorded in Official Records
County of Riverside
Larry W. card
Assessor, County Clerk 8 Recorder
1111111 IIIIIII 11111111111111111111111111111111111111111
S J R I U I PAGE I SIZE I UA I MISC
A I L 1 465 1 426 LPCOAG:)RI SM
GRANT DEED
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX IS $770.00
[ X ] computed on full value of property conveyed, or
[ - ] computed on full value less value of liens or encumbrances remaining at time of sale.
[ - ] unincorporated area [ X ] City of La Quinta
FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged,
Frederick D. Smith, Trustee of The Frederick D. Smith Living Trust, dated May 15, 2000
RFD I COPY
UNI
hereby GRANT(S) to Steven Elliott and Gerd Elliott husband and wife as joint tenants
the following described real property in the County of Riverside, State of California
See Exhibit "A" attached hereto and made a part hereof.
Dated: September 12, 2008
STATE OF CAj4FORNIA
COUNTY OF V—N WA5,1" } SS.
On 2k 1"1 &009 before me
ttoPublic, personally appea ed
_d-cr tCiL 0 • S; V% ttN
who proved to me on the basis of satisfactory evidence to be
the person(s) whose name(s) is/am subscribed to the within
instrument and acknowledged to me that he/sheAhey
executed the same in his/hedtheir authorized capacity(ies)
and that by his/he+Aheir signatures) on the instrument the
person(s), or the entity upon behalf of which the person(s),
acted, executed the instrument. tOLI 999 IIIA
RY under the laws of N01AR'/ PUB11C • ('J411FORNII
oing paragraph is true RIVERSIDE COUNTY
I
(This area for official notary seal)
MAIL TAX STATEMENTS AS DIRECTED ABOVE
The Frederick D. Smith Living Trust,
dated May 15, 2000
I --I �- ---
I - F�e
By: Frederick D. Smith, Trustee
I certify under PENALTY OF PERJU
the State of Californiaalifothat the foreg
and correct.
WITNESS my �rhanndl and official seal.
Signature C16U t,',' YVN
Signature of Notary
COMM. • 17717
� .
• �
Conrn. JW 28, 2011
R
Z
File No: 68621507
EXHIBIT "A"
All that certain real. property situated in the County of Riverside, State of California, described as
follows:
Lot 304 (the "Lot') of amended Tract No. 29894-2, in the City of La Quinta, County of Riverside,
State of California, as shown on a Subdivision Map (the "Map") recorded on December 12, 2002, in
Book 327, Pages 56 to 58, inclusive, of Maps, in the Office of the Riverside County Recorder.
EXCEPT therefrom all oil, gas, minerals, and other hydrocarbon substances lying bebw the surface
of said land, but with no right of surface entry, as provided in deeds of record.
ILLEGIBLE NOTARY SEAL DECLARATION
GOVERNMENT CODE 27361.7
I CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL ON THE
DOCUMENT WHICH THIS .STATEMENT IS ATTACHED. READS AS FOLLOW:
NAME OF NOT.
j-, -,(-n. oxo L -
COUNTY WHERE BOND IS FILED:0✓1 -L".
DATE COMMISSION EXPIRES: 7
PLACE OF EXECUTION
F THE DECLARATION: SAN BERNARDINO
Wa DATE: o U�
COMMISSION NUMBER:
SOUrORNELAS ITLE
LUCI
TITLE ASSISTANT
A.
DOC # 2009-0340850
WHEN RECORDED MAIL TO: 07/02/2009 08:00A Fee:21.00
Page 1 of 5
Recorded in Official Records
Steven Elliott and Gerri Elliott county of Riverside
20331 NE 61st Court Larry W. Ward
Assessor, County Clerk d Recorder
Redmond, WA 98053 111111111111111111111
11111111 III 1111111 III 11111 ILII 1111
S. r R I U I PAGE J SIZE I DA I MISC I LONGI RFD I COPY
M A I L 1 465 1 426 rCO NCORI SMF JNCHGJ ---
IT: CTY UNI 0- "
MAIL TAX STATEMENTS TO: SPACE ABOVE THIS LINE FOR RECORDER'S US
DOCUMENTARY TRANSFER TAX $ tJ 14 ccv'o17t.p-A3ION
SAME AS ABOVE [ I COMPUTED ON THE CONSIDERATION OR VALUE OF PROPERTY CONVEYED: O
[ I COMPUTED ON THE CONSIDERATION OR VALUE LESS LIENS OR
ENCUMBRANCES REf.9AINING AT TIME OF SALE.
APN: 777-160-021, 777-160-022
SIGNATURE OF DECLARANT OR AGENT DETERMINING TAX - FIRM NAME
GRANT DEED
FOR A VALUABLE CONSIDERATION, receipt of.which is hereby acknowledged,
Steven Elliott and Gerri Elliott, husband and wife as joint tenants.
hereby GRANT(S) to
Steven Elliott and Gerri Elliott, husband and wife as joint tenants.
the real property in the State of California. County of Riverside, City of La Quinta, described as
PARCEL "A"
Lots 304 and 305 of Amended Tract No. 29894-2, in the City of La Quinta, County of Riverside, State of
California, as shown by map on file in Book 327, page 56 to 88 records of Riverside County, California.
DEED REFLECTS PARCEL MERGER NO.: 2009-488 AS APPROVED BY THE CITY OF LA QUINTA.
Dated V ! v 'A -4v 'w�
-( " T&.Q'tr
TEOfC6 (�AS�trg<<Tl7N
)ss.
INTY OF l< i N Cj V
algloq before me
N1AL1a
proved to me cn the basis of satisfactory evidence) to be the person(s) whose name(s) istare s4
:rument and acknowledged to me that hetshei" executed the same in histher/their authorized
her/their signature(s) on the instrument the person(s) or the entity upon behalf of which the per:
my hand and official seal.
r
iai`i�ty(ies), avpliat'by
s�iaCtedrexeCut�d the :'Z
�% �eC f C
o�k
--/4SH NG'%Oii
(This area for official notary seal)
MAIL TAX STATEMENTS AS DIRECTED ABOVE
EXHIBIT "A"
CERTIFICATE OF PARCEL MERGER NO. 2009-488
RECORD OWNERS EXIS71NG PARCELS ASSESSORS PARCEL NUMBERS
Steven Elliott and Gerd Elliott 777-160-021
Steven Elliott and Gem Elliott 777-160-022
LEGAL DESCRIPTION OF MERGED PARCEL
PARCEL " A"
Lots 304 and 305 of Amended Tract No. 29894-2, in the City of La Quinta, County of Riverside,
State of California, as shown by map on file in Book 327, page 56 to 88 records of Riverside
County, California.
The above described Parcel "A" contains 44,400 square feet or 1.019 acres, more or less.
ti� cA
D
LS %5V1
N DW R£S °9/30/2010
F
DAQF�
APPROVED 8Y CITY OFaA'Q1INRA
PI ING DEPARTMENT
8Y DATE
Exhibl
ACKNOWLEDGMENT
State of California
County of Riverside
On 04/27/2009 before me,
(here insert name
personally appeared Yvonne Franco
n9.0,
J title of the
who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s)
is/are subscribed to the within instrument and acknowledged to me that he/she/they
executed the same in his/her/their authorized capacity(ies), and that by his/her/their
signature(s) on the instrument the person(s), or the entity upon behalf of which the
person(s) acted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State of Cal-.fornia that the
foregoing paragraph is true and correct.
WITNESS my hand and official seal.
1 �
Signaturet. a�. �.
(Seal)
5 MEtA S. WHO
CO MulM 11723211
f NO" Iubft, • CollfotNo
* RW*Mldt County
�M CDf tM1i 6�� fib 2.2011
EXHIBIT "C"
SITE PLAN
CERTIFICATE OF PARCEL MERGER NO. 2009-488
AMENDED TRACT 29894-2
MB 327/56-88
(Lot 303)
APN: 777-1 GO -020
Graded lot
No 5tructure5
ro \ �A
DR54, /,, aE� S 4g 32. PSS
(L s35.8 ��j 0 R� 0
a
(Lot 304) �, Pv�
APN: 777-160-021 N
Graded lot
No Structures
(28,888 sq.Ft.)r"N"
G.30`i \
O.G63 acres
OT LINE TO BE
.PARCEL BANDONED
ro 44,400 sq.ft. 1.019 Acres
0
(Lot 305) otic
63l
(Lot "U°)
\ r
APN: 777-1 60 022 u) (Lot 30G)
Graded Lot Z! `
No structures APN: 777-0 60-023 a)
Gradezi lot ^1
(15,512. sq.ft.) NoStru-tures M fl
0.356 acres
0
Utog3,
/i . (Lot 41AAR) 7
"Golf Course" (325. 6'
{ } Denotes Record Data per MB 327/56-88
Curve
Delta
Rachu5
Length
1
(53°31 X08)
(27.00)
(25.22)
2
{ 17° 1 0'00)
(1 16.00)
(34.76)
3
(17°43-271()
! 6.001
{35.889
4
1 (35"57-491
(1 16.00)
(72.81)
Record Owner. Steven Elliott and Gem Elliott
Address: 20331 NE 61 St. Court - Redmond, WA 98053
Map Prepared By: Andrew Y. Orosco
Address: PO Box 1249 Riverside, Ca 92502
Scale: 1"=601
Assessor's Parcel No: 777-160-021 & 022
Par�.el 1�er er
APPROYEDW G 7Y OFLAQ MA
PLANNING DEPARTMENT
BY VW DATE.
Exhibi
EXHIBIT B
CERTIFICATE OF PARCEL MERGER NO. 2009-488
3°54, gS, �S
(R 2 �• ,3
(L �B6
5• ¢7 R�
) � ti
9/So�2dio T
� �
c9
Radlu5
Length
CA"n
0z
`.D TRACT No. 29894-2
MB 327/56-88
J
(Lot 303)
o
E
ILI
vz 9 oa�, • 1 \
(Lot 304)
(28.888 eq. ft.)
0.663 acres
(10'
(Hgp°58 l O E)
LOT LINE TO BE
ABANDONED
P
�� to
%5\ N PARCEL "A"
44,400 sq. Ft. 1.0 19 Acres
N (Lot 305)
►� (15,512. sq.Ft.)
0.356 acres
to
u�J =/
Record Owner. Steven Elliott and Gerd Elliott
Address: 20331 NE 61 St. Court
Redmond, WA 98053
Map Prepared By: Andrew Y. Orosco
Address: PO Box 1249, Riv, 92502
Area/District
3l (87.3;
P�
(Lot "U°)
7"Un, (
(Lot 306
rL
(1 10.32
(N79°31 'r
(Lot 'AN-) - W
{ } Denotes Record Data per MB 327/56-88
Curve
Delta
Radlu5
Length
1
(53°31'089
(27.00)
(25.22)
2
(1701 0VG1
(i 16.00)
(34.76)
3
(17°43'271
(1 16.00)
(35.88)
4
(35°57'49
(1 16.00)
1 (72.81)
DEPARTMENT USE ONLY
This Certificate of Parcel Merger No.:
is hereby approved.
By:
Title: 5�.�WvWke /
Date: q -2'mco�
325. 67
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN -SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated & effective 9/25/2009
Green Sheet aoorovals are forwarded to the Buildina & Safety Department directly by Pudic Works. Please DO
NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works D#4;0 ent until ALL
requirements listed below are complete. Incomplete applications or applications which cannocessed will be
returned to applicant.
Date: _L/ / Developer: 916hdfP_ V�71
Tract No.:
`� `'1 Tract Name:
_8"_�' 1 14'
Lot No.(s): .��� 32 1?)' 21//V
I,
Phone Number: (
MFH
The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the
Building & Safety Department:
❑ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW
❑ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW
❑ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW
❑ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW
1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad
(maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6
months of current date). If a precise grading plan creates the pad for approval, plerse withhold green sheet
submittal until a Pad Elevation Certificate can be provided.
rQ Attach geotechnical certification of grading plan compliance including compaction reports from a licensed
Soils Engineer. Recently rough graded residential developments which have a previously approved
geotechnical certification are exempt from this requirement.
Attach recorded final map or title information/grant deed showing proposed building locations are legal lots.
Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10
plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy
plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with
grading plans & are -subject to additional requirements. A current PM10 certification number is required.
Attach a copy of the rough or precise grading plan to the Public Works Department showing building
location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain
development plan.
6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations.
QComplete and sign the attached water quality management plan (WQMP) exemptior form, if applicable. PW
approved building construction projects require either a WQMP or a completed V�QMP exemption form.
Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanC-ieck/m search.aspx
I have reviewed and confirmed the requirements listed above as presented and find the improvements to be
sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s).
Pursuant to my findings, the above project may be released for building permit issuance.
This section completed by City staff.
Recommended by: I _ Date: S / 9 / ' `7
Public Works Distribution: ( ) Green Sheet to Building & Safety
( ) Green Sheet to Planning Department
Declined for approval for reason(s) as follow(s), please correct and resubmit:
TAChecklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 10-02-12.doc
City of La Quinta - PM 10 Fugitive Dust Control Project Information
Construction Phase PM 10 Aareement (< 1 acre/lot or Infill Proiect)
Project Information
Project Contractor:
Project Phase
Project Name: 6�1( ( O [
(check one) .
Project Tract/Lot Numbers:
❑ Construction
.0 Demolition
Project Street Address:
Total Acres in Active
Anticipated Start Date: / 6 4
Anticipated Completion Date:
Construction (< 1 acre per
Lot):
PM10 Contact Information
Please note: Dust control is required
24 hours a day, 7 days a week, regardless of
construction status. ' Person listed
below is responsible for dust control during
business and non -business hours.
Name:
Title:
Company Name:
Mailing Address:
3%9—
City, State, ZIP Code:
Primary Phone #:
Fax #:
24 Hour Emergency
�S-� / Lu 1
Phone#:
7
Cell Phone #:
�j
aS0 I -T46), 315
Email Address:
coh r
G
PM 10 Certificate #:
�% V� Z -- b7
The above stated property owner (or authorized representative):
❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to
SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP;
Shall constitute an Agreement to comply with all project conditions as identified in the approved dust
control plan.
❖ Acknowledges that dust control is required twenty-four. (24) hours a day, seven (7) days a week,
throughout the period of project performance, regardless of project size or status;
❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project
shall be in continuous compliance with all requirements of the approved dust control plan;
❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the
dust control plan are necessary,;
❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement
purposes;
❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust
control plny City/Count�inniitia�teddabatement activities. ,
-- J.
Signature of Propert •Owne or uthorized Representative Da e
Building Permit Number:
Project Description: SFR
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Datel 5/8/14
Job Site Address
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E -Mail Address
Project Manager's Name
Project Manager's Phone Number
Project Manager's E-mail Address
Builder / Contractor
Number, Street or PO Box
City, State, Postal Code
Project Square Footage
City Approval By
Date of City Approval
Materials To Be Discarded:
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse*
*Describe Items
80559 Via Pessaro
Steve Elliott
80559 Via Pessaro
La Quinta, CA. 92253 *04
425-802-4290 A/lq` +
Mike Jeha
760-200-3756 Pp
iehaconstruction@aol.com 0Ai4
Mike Jeha Construction
3089 Sandstone Rd
Alamo, CA. 94507
approx. 8000 sq ft
Tons
22.00 Not recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
23.00 Recyclable
2.25 Recyclable
0.00 Recyclable
Totals: Recycle Trash
F--3-9-.-3-1 1 22.0
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
5.50 Recyclable
0.00 Recyclable
0.50 Recyclable
0.75 Recyclable
7.25 Recyclable
0.00 Recyclable
Projected Diversion:
64.08%
1 understand it is the property ownets responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris
Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from
landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from
the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the
property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent
of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner
retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor
shall be kept informed of the diversion progress through bi-mont eports. If self -hauling, all refuse material from this project site
must betaken to an approved recycler or t sfer tion.
�p
1
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Elliott Residence
Lots 304 & 305 Via Pessaro
La Quinta, CA
Project Designer:
Ochoa Design Associates
Palm Desert, Ca 92260
760-773-6605
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
Job Number:
REC7plVED
MAR 2.0 2014
C0M��°ZIVrA
'E OF ELOPINE
NT
Date:
UI D 2%25/20"�14U11� T
`G & SAI'FEl-y DCPA
A PPRr)\,/r-�,
The EnergyPro computer program has been used to perfoim the calculations•summar¢ed in this com liance report. This program has approval and is
authorized by the California Energy Commission for use with bothrthe ederi`tia�and�N� nnresiden al 2008 Building Energy Efficiency Standards.
This progrgm dovP-4a,
y ergyS , LLC–www.energyi oft.com.
EnergyPro 5.1 by EnergySoft User Number: 2655_ o : 20 - 25T_i6:26:46 I ID:
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Elliott Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2125/2014
Project Address
Lots 304 & 305 Via Pessaro
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,893
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 7,893 Perim = 112' New
Wall Wood Framed
R-19 3,032 New
Roof Wood Framed Attic
R-38 7,893 Radiant Barrier New
FENESTRATION
Orientation Area
U- Exterior
Factor SHGC Overhang Sidefins Shades Status
Front (N) 289.5
0.590 0.40 2.0 none Bug Screen New
Left (E) 173.0
0.590 0.40 10.0 none Bug Screen New
Left (E) 181.5
0.590 0.40 2.0 none Bug Screen New
Rear (S) 390.0
0.590 0.40 10.0 none Bug Screen New
Rear (S) 329.2
0.590 0.40 2.0 none Bug Screen New
Right (1) 209.3
0.590 0.40 10.0 none Bug Screen New
Rear (SM 30.0
0.590 0.40 2.0 none Bug Screen New
Right (Vo 48.0
0.590 0.40 2.0 none Bug Screen New
Rear (SIAL 48.0
0.590 0.40 10.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating
Min. Eff Cooling Min. Eff Thermostat Status
4 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
New
1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Whole House Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
Casita Ducted
Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING
. Type
t
Gallons, y Min. Eff',Di iiutionOOt Status
2 Small Gas
40 r , 0.62 'All Pipes Ins * J New
1 Small Gas
50 f 10.62C�� Pipe Insulation New
D,yfE
EnergyPro 5.1 by EnergySoft User Number. 2655 `- --RunCode: 201402-25716:26:46 -.ID: N
Page 3 of 15
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Elliott Residence I
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2125/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 3,602.0 ft2 Covered Slab Floor, 3.500° thick at Whole House
HIGH MASS Design - Verify Thermal Mass: 3, 000.0 ft2 Exposed Slab Floor, 3.500" thick at Whole House
HIGH MASS Design - Verify Thermal Mass: 1,291.0 ft2 Covered Slab Floor, 3.500° thick at Casita
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System BDP CO. 563AN048-A includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System Whole House includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfin.
The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System Whole House indudes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System.
The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria.
The Cooling System BDP CO. 563AN036-A includes credit for a 11.0 EER Condenser. A certified HERS rater must fieid verify the installation of the
correct Condenser.
The HVAC System Casita includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.
The HVAC System Casita incorporates HERS Verified Refrigerant Change or a Charge Indicator Display.
The HVAC System Casita includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System. r--_
The HVAC System Casita incorporates HERS verified Duct Leakage. HERS; field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria. + ;� ;— A
n�:-.a�yj-.
7-Y r)
v
EnemyPro 5. 1 bv EnemySoft User Number. 2655 Rundode:2014-0225716:26:46 ID: N Page 4 of 15
PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family O Addition Alone
Date
Elliott Residence
1 ❑ Multi Family E3 Existing+ Addition/Afteration
2/25/2014
ANNUAL ENERGY USE SUMMARY
Standard Amposed Margin
TDV kBtu/ftz_
Space Heating 2.23 3.77 -1.54
Space Cooling 45.36 42.60 2.76
Fans 8.88 9.37 -0.49
Domestic Hot Water 4.62 5.20 -0.56
Pumps 0.00 0.00 0.00
Totals 61.10 60.94 0.16
Percent Better Than Standard: 0.3%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
enestration
Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,020 290
Fuel Available at Site: Natural Gas (t7 1,150 355
Raised Floor Area: 0 (S) 1,650 797
Slab on Grade Area: 7.893 (W) 910 257
Average Ceiling Height: 10.8 Roof 7,893 0
Fenestration Average U -Factor: 0.59 TOTAL:. 1,699
Average SHGC: 0.40 Fenestration/CFA Ratio: 21.5
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the Califomia Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company lnsu-conn, inc.
2/152014
Address 77810 Los Montanas Road, Suite 201 Name Joan D. Hacker aA; 14 L4
C'/State/ZipCfty/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Sig Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)— _ -_
Com Ochoa Design Associates ". i , r C �—
Pant 1 r �
QU,f.t`� NG
Address �a & 13 F ��, t ec�.�� oa 1711y
City/Stateop Palm Desert, Ca 92260 hone 760-773=66051- 1= Signed License # Date
:3 fM
FG (`r.,,$-- ,
� ; Ju I ION
EnergyPip 51 by EnemySoft User Number. 2655 AunCade: 2014-02-25T18.26:46 1D: N Pace 5 of 15
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R
Project Name
Elliott Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1212512014
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavi Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
3,602
0.730 None
0 180 New 4.4.7-A1
Whole House
Slab
3,000
0.730 None
0 180 New 4.4.7-A1
Whole House
Wall
660
0.074 R-19
0 90 New 4.3.1-A5
Whole House
Wall
494
0.074R-19
90 90 New 4.3.1-A5
Whole House
Wall
29
0.074 R-19
180 90 New 4.3.1-A5
Whole House
Wall
341
0.074 R-19
270 90 New 4.3.1-A5
Whole House
Roof
6,602
0.025 R-38
0 0 New 4.2.1-A21
Whole House
Slab
1,291
0.730 None
0 180 New 4.4.7-A1
Casita
Wall
320
0.074 R-19
225 90 New 4.3.1-A5
Casita
Wall
71
0.074.R-19
0 90 New 4.3.1-A5
Casita
Wall
302
0.074 R-19
90 90 New 4.3.1-A5
Casita
Wall
352
0.074 R-19
180 90 New 4.3.1-A5
Casita
Wall
312
0.074 R-19
270 90 New 4.3.1-A5
Casita
Wall
152
0.074 R-19
225 90 New 4.3.1-A5
Casita
Roof
1,291
0.025 R-38
0 0 New 4.2.1-A21
Casita
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status Glazing Type
Location/Comments-
1
Window
22.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
2
Window
40.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alurnkow-E
Whole House
3
Window
39.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
4
Window
39.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
5
Window
48.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
6
Window
7.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
7
Window
4.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
8
Window
4.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
9
Window
9.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
10
Window
22.5 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E
Whole House
11
Window
6.0 0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low--E
Whole House
12
Window
48.0 0.590 NFRC
0.40 NFRC 90 New IWC 6200 Alum/Low-E
Whole House
13
Window
32.5 0.590 NFRC
0.40 NFRC 90 New IWC 6200 Alum/Low-E
Whole House
14
Window
48.0 0.590 NFRC
0.40 NFRC 90 New IWC 6200 Alum/Low--E
Whole House
15
Window
12.0 0.590 NFRC
0.40 NFRC 90 New IWC 6200 Alum/Low-E
Whole House
16
Window
32.5 0.590 1 NFRC
0.40 NFRC 90 New IWC 6200 Alum/Low-E
Whole House
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC T 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist I Len H t Dist Len H t
1
Bug Screen
0.76
5.5 4.0 2.0 0.1 2.0 2.0
2
Bug Screen
0.76
8.0 5.0 2.0 0.1 2.0 2.0
3
Bug Screen
0.76
8.0 4.5 2.0 0.1 2.0 2.0
4
Bug Screen
0.76
8.9 4.0 2.0 0.1 2.0 2.0
5
Bug Screen
0.76
8.0 6.0 2.0 0.1 2.0 2.0
6
Bug Screen
0.76
3.5 2.0 2.0 0.1 2.0 2.0
7
Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
8
Bug Screen
0.76
2.0 2.0 2.0 0.1 2.0 2.0
9
Bug Screen
0.76
3.0 3.0 2.0 0.1 2.0 2.0
10
Bug Screen
0.76
4.5 5.0 2.0 0.1 2.0 2.0
11
Bug Screen
0.76
3.0 2.0 2.0 -0.1 __ 2.0 2.0
12
Bug Screen
0.76
8.0 6.0 10.0 CO. +-;10.0 . -10.0
13
BU Screen
0.76
6.5 5.0 10.0 _-0.1 10.0 I f 10.0 l
14
Bu Screen
0.76
8.0 6.0 10.0 '� 0:1. _1_110.0 > 010.0 ` _ "� � r PV g
i
15
Bu Screen
0.76
2.0 6.0 10.0 0.1 , 10.0 `10.0 0-t_ 1 Y` F)C
16
Bug Screen
0.76
6.5 5.0 10.0 0. b J0.0 I-10,0 1 e r
' SUR CONSTRUCTION
EnergyPro
5.1 by EnergySoft User Number. 2655
RunCodes 2014-02-25716:26:46 ID:
Page 6 of 15
CERTIFICATE OF COMPLIANCE: Residential Part L of 5 CF-1 R
Project Name
Elliott Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1212512014
OPAQUE SURFACE DETAILS
Surface U- Insulation
Type Area Factor Cavi Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
LI-Factor'
SHGC2
Azm Status Glazing Type
Location/Comments
17
Window 9.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low--E
Whole House
18
Window 9.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alurnkow-E
Whole House
19
Window 54.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alurnkow-E
Whole House
20
Window 4.5
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low--E
Whole House
21
Window 3.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alurnkow-E
Whole House
22
Window 3.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
23
Window 3.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
24
Window 24.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
25
Window 24.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low--E
Whole House
26
Window 48.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alurnkow-E
Whole House
27
Window 6.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
28
Window 24.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alurnkow-E
Whole House
29
Window 48.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alurnkow-E
Whole House
30
Window 24.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
31
Window 23.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alurnkow-E
Whole House
32
Window 21.3
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
(1) Ll-Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade T
e SHGC
Window
H t Wd
Ove ang Left Fin
Len Hqt LExt RExt Dist Len Ht1t
Ri ht Fin
Dist Len H t
17
Bug Screen
0.76
4.0 5.0 2.0 0.1
2.0 2.0
18
Bug Screen
0.76
4.0 2.5 2.0 0.1
2.0 2.0
19
Bug Screen
0.76
9.0 6.0 2.0 0.1
2.0 2.0
20
Bug Screen
0.76
3.0 1.5 2.0 0.1
2.0 2.0
21
Bug Screen
0.76
3.0 1.5 2.0 0.1
2.0 2.0
22
Bug Screen
0.76
3.0 1.5 2.0 0.1
2.0 2.0
23
Bug Screen
0.76
3.0 1.0 2.0 0.1
2.0 2.0
24
Bug Screen
0.76
8.0 3.0 2.0 0.1
2.0 2.0
25
Bug Screen
0.76
8.0 3.0 2.0 0.1
2.0 2.0
26
Bug Screen
0.76
8.0 6.0 10.0 0.1
10.0 10.0
27
Bug Screen
0.76
3.0 2.0 10.0 0.1
10.0 10.0
28
Bug Screen
0.76
8.0 3.0 10.0 0.1
10.0 10.0
29
Bug Screen
0.76
8.0 6.0 10.0 0.1
10.0 10.0
30
Bug Screen
0.76
8.0 3.0 10.0 0.1
10.0 10.0
31
18ug Screen
0.76
8.0 2.9 2.0 0.1
2.0 2.0
32
JBug Screen
i 0.76
8.0 2.8 2.0 0.1
2.0 2.0--+-.-
EnergyPro
5. 1 by EnergySoft
User Number: 2655
RunCode: 201402-25716:26:46 -ID: J
I Pae 7 of 15
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Elliott Residence
Building Type ® Single Family O Addition Alone
❑ Multi Family O Existing+ Addition/Alteration
Date
9/9 014
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC
Azm Status Glazing Type
Location/Comments
33
Window 48.0
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low-E
Whole House
34
Window 21.3
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low-E
Whole House
35
Window 39.0
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low--E
Whole House
36
Window 66.0
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low-E
Whole House
37
Window 2.3
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low--E
Whole House
38
Window 39.0
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low•E
Whole House
39
Window 21.3
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alumkow-E
Whole House
40
Window 240.0
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alurnkow-E
Whole House
41
Window 48.0
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E
Whole House
42
Window 2.3
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E
Whole House
43
Window 30.0
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E
Whole House
44
Window 60.0
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E
Whole House
45
Window 30.0
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E
Whole House
46
Window 39.0
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E'
Whole House
47
IWndbw 22.0
0.590 NFRC
0.40 1 NFRC 225 New IWC 6200 Alurnkow-E
Casita
48
IiAAndow 8.0
0.590 NFRC
I 0.40 NFRC 1 225 New IWC 6200 Alum/Low-E
I Casita
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t TWd
Ove hanq Left Fin
Len Hgt LExt RExt Dist Len
Ri ht Fin
H t Dist Len H t
33
Bug Screen
0.76
8.0 6.0 2.0 0.1 2.0 2.0
34
Bug Screen
0.76
8.0 2.8 2.0 0.1 2.0 2.0
35
Bug Screen
0.76
8.0 4.5 2.0 0.1 2.0 2.0
36
Bug Screen
0.76
11.0 6.0 2.0 0.1 2.0 2.0
37
Bug Screen
0.76
1.5 1.5 2.0 0.1 2.0 2.0
38
Bug Screen
0.76
8.9 4.0 2.0 0.1 2.0 2.0
39
Bug Screen
0.76
8.01 2.3 2.0 0.1 2.0 2.0
40
Bug Screen
0.76
10.01 24.0 10.0 0.1 10.0 10.0
41
Bug Screen
0.76
8.01 6.0 10.0 0.1 10.0 10.0
42
Bug Screen
0.76
1.5 1.5 10.0 „0.1 10.0 10.0
43
Bug Screen
0.76
10.0 3.0 10.0 1 0.1 110.0 --10.0
44
Bug Screen
0.76
10.0 6.0 10.0 1 0..1 t 10.0 10.0
45
Bug Screen
0.76
10.0 3.0 10.0 0.1 : , 10.0 -10.0�-
46
Bug Screen
0.76
6.5 6.0 10.01 0.1-'-,10.0 k; 10.0
�1 1
47
JBug Screen
0.76
5.5 4.0 2.0 0.1 A1 2.0 .--. . 2.0
48
JBug Screen
0 76F--4OT
2.0 2.0; 0. f -,_ '2.0 : -r-2.0
EnergyPro,
5.1 by EnergySoft
User Number.- 2655
Run Cocfe'-461Q 02-25716:26:46 ID:
1 Page 8 of 15
� BY
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Elliott Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1212512014
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
Ll -Factor
SHGC
Azm Status Glazing Type Location/Comments
49
Window 8.0
0.590 1 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
50
Window 11.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
51
Window 11.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
52
Window 11.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
53
Mndow 8.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low--E Casita
54
Window 48.0
0.590 NFRC
0.40 NFRC 90 New IWC 6200 Alum/Low--E Casita
55
Window 48.0
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low-E Casita
56
Window 48.0
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E Casita
57
Window 48.0
0.590 NFRC
0.40 NFRC 225 New IWC 6200 Alum/Low-E Casita
(1) Ll -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
HqATWd
Ove anq Left Fin Ri ht Fin
Len I Hqt LExt RExt Dist I Len Hat I Dist Len H t
49
Bug Screen
0.76
4.01 2.0 2.0 0.1 2.0 2.0
50
Bug Screen
0.76
5.51 2.0 2.0 0.1 2.0 2.0
51
Bug Screen
0.76
5.5 2.0
2.0 0.1 2.0 2.0
52
Bug Screen
0.76
5.5 2.0
2.0 0.1 2.0 2.0
53
Bug Screen
0.76
4.0 2.0
2.0 0.1 2.0 2.0
54
Bug Screen
0.76
8.0 6.0
2.0 0.1 2.0 2.0
55
Bug Screen
0.76
6.8 6.0
2.0 0.1 2.0 2.0
56
Bug Screen
0.76
6.8 6.0
2.0 0.1 2.0 2.0
57
Bug Screen
0.76
8.01 6.0
10.0 0.1 10.0 10.0
L� 1 L1h,)T I
r�. t GUiVS I �'t�C1 ON
EnergyPro
5.1 by EnergySoft
User Number. 2655 RunCode:.2014-02-25716:26:46 ID: [ Page 9 of 15
CERTIFICATE OF COMPLIANCE: Residential Part E of 5)
CF -1 R
Project Name
Elliott Residence
Building Type ® Single Family ❑ Addition Alone:
❑ Multi Family ❑ Existing+ Addi-ion/Alteration
Date
V25/2014
BUILDING ZONE INFORMATION
System Name
Floor Area
Zone Name New Existing Altered Removed Volume Year Built
Whole House Whole House 6,602
72,622
Casita Casita 1,291
12,910
Totals 1 7,8931 0 0 0
HVAC SYSTEMS
System Name City.
Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Whole House
4 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setbad.(
New
Casita
1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setbact<
New
HVAC DISTRIBUTION
System Name
Duct
Heating Cooling Duct Location R -Valle
Ducts
Tested? Status
Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0
® New
Casita Ducted Ducted Attic, Ceiling Ins, vented 8.0
® New
WATER HEATING SYSTEMS
S stem Name
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy StF-ndby
Factor Lass or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
A. 0. SMITH FPS -40-224
2
Small Gas
All Pipes Ins
42,000
40
0.62 a/a
n/a
New
A. 0. SMITH FPS -50-224
1
Small Gas
No Pipe Insulation 1
43,0001
50
1 0.62 i/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
c
0
m
�o
a —
4
—S stem -Name-
Pipe
Length
Pipe
Diameter
Insul.
Thick.
QtYTHP
Plenum Outside Buried
0.
EnergyPro 5.1 by EnergySoft
User Number 2655 RunCode: 2014-02-25716:26:46 ID: N
Pae 10 of 15
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R
Project Name
Date
Elliott Residence
1212512014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage
§116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form.
§118(1): The thermal emittance and solar reflectance. values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is s ecified on the CF-1 R Form.
*§1 50a : Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
*§1 50c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor.
*§1 50d : Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight-fitting damper and or a combustion-air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are extemally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(50(WA: Insulation is protected from damage, including that due to sunli "ht' moisture–, —equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or enclosed-entirely in
conditioned space. l 0 UIL F)I Ir_, o ., „ `a` °� r V
150 ' 4: Solar water-heating systems and/or collectors are certified b' the Sola. Rating and &hification Goy ation.
FGRCC "STRUG
I
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2014-02-25T16:26:46 ID: jj Page 11 of 15
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Elliott Residence
12/25/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
§150(m)10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only durin off-peak electric demand periods.
150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet. - - -
r -
I r +
fj CC r
JI�
r
EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2014-02-25T16:26:46 ID: " 1 Page 12 of 15
1Jf11 ):
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Elliott Residence
1212512014
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with 150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
C,- LA QUINTA
FBULDING S,gFE7Y DEP T
-
IVE
CONSTRUCTION
EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2014-02-25T16:26:46 ID: Page 13 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Elliott Residence
Date
2/25/2014
System Name
Whole House
Floor Area
6,602
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
4
COIL
CFM
Total Room Loads 3,437
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent I CFM
Sensible
Output per S em
72,000
67,395
4,922 1,544
68,075
Total Output Btuh
288,000
0
Output Stuh/ ft
43.6
3,891
3,346
Cooling System
0
0
Output per S em
48,000
0
0 0
0
Total Output Btuh
192,000
0
3,891
1 75,176 4,922
0
Total Output ons
16.0
3,346
Total Output Btuh/s ft
29.1
Total Output s ftrron
412.6
1 74,766
Air System
CFM per System
1,595
HVAC EQUIPMENT SELECTION
Airflow(cfm)
6,380
BDP CO. 563AN048-A 132,875 37,575 288,000
Total Adjusted System Output 132,875 37,575 288,000
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Airflow cfm/s ft 0.97
Airflow cfmfron 398.8
Outside Air°/6)
0-0%
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 70 OF
Outside Air
0 cfm Supply Fan
6,380 cfm
70 OF
70 OF 112 OF
Heating Coil 111 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 79/65°F 79/65°F 59/58°F
0'
Outside Air
0 cfm Supply Fan Cooling Coil 60 / 58 OF
6,380 cfm
�-�.-49.2°� ROOM
L.il� LIN 79/65°F _iNG & -SAFETY pEPT, I
7CS,78/I65 OF
A
FOR CONSTRUCTION
EnergyPro 5.1 6y EnergySoff User Number. 2655 RunCode. 2014-02-25716.26.46 /D: I Page 14 of 15
I uHit�_(3Y I
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Elliott Residence
Date
2/25/2014
System Name
Casita
Floor Area
1,291
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 707
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 56,000
16,781
1,006 476
17,416
Total Output Btuh 56,000
0
Output Btuh/ ft 43.4
969
856
Cooling System
0
0
Output per System 35,000
0
0 0
0
Total Output Btuh 35,000
0
1,006
0
Total Output ons 2.9
969
856
Total Output Btuh/s ft 27.1
Total Output s ftrron 442.6
1 18,718
19,128
Air System
CFM per System
1,300
HVAC EQUIPMENT SELECTION
Airflow (cfm)
1,300
BDP CO. 563AN036-A 27,601 2,382 56,000
Total Adjusted System Output 27,601 2,382 56,000
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK Avg 3 PM Jan 1 AM
Airflow cfm/s ft 1.01
Airflow cfm/Ton 445.7
Outside Air % 0.0%
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 69 OF
Outside Air
0 cfm Supply Fan
1,300 cfm
69 OF
Sir -
69 OF 105 OF
-
Heating Coil 104 OF
ROOM
70 OF
4
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 79/63°F 79/63°F 55/54°F
—
Outside Air4 r
Yr GF LA C UUINTq0 cfm Su I Fan Cooling Coil 56 / 54 °F
PPY FFOR
1,300 �„ IL��DyING & SAFF `/Ai'"iPj� y�jV��007/F79 / 63 °F CONSTRUCTION $ 62 °
rn
DATE --�_ BY
EneigyPto 5.1 by EnergySoR User Number. 2655 RunCode: 2014-02-25T16:26:46 ID: j Page 15 of 15
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 2/27/2014
Electronically Signed at CalCERTS.com by Michael Jeha (Michael Jeha Construction) 3/5/2014
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Elliott Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2/27/2014
Project Address
Lots 304 & 305 Via Pessaro
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7, &
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity ( Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 7,893 Perim = 112' New
Wall Wood Framed
R-19 3,032 New
Roof Wood Framed Attic
R-38 7,893 Radiant Barrier New
FENESTRATION
Orientation Area(ft)
U- Exterior
Factor SHGC Overhang Sidefins Shades Status
Front (N) 289.5
0.590 0.40 2.0 none Bug Screen New
Left (E) 173.0
0.590 0.40 10.0 none Bug Screen New
Left (E) 181.5
0.590 0.40 2.0 none Bug Screen New
Rear (S) 390.0
0.590 0.40 10.0 none Bug Screen New
Rear (S) 329.2
0.590 0.40 2.0 none Bug Screen New
Right (W) 209.3
0.590 0.40 10.0 none Bug Screen New
Rear (SW) 30.0
0.590 0.40 2.0 none Bug Screen New
Right (W) 48.0
0.590 0.40 2.0 none Bug Screen New
Rear (SW) 48.0
0.590 0.40 10.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating
Min. Eff Cooling Min. Eff Thermostat Status
4 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback New
1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Whole House Ducted
Ducted Attic, -Ceiling Ins; vented ----_8.0 New
Casita Ducted
Ducted Attic; Ceiling Ins,', vented - L . At t')j 8:6 r -j" A I New
G .0% rF 7v nF:Az 1
WATER HEATING
Ot . Type
Gallons Min. Eff DistribiutionJS-T1 l; rr7 ;n,, Status
2 Small Gas
40 0.62 All Pipes InsNew
1 Small Gas
50 0.62 .= No'Pipe_ s i y� , New
;1
LEnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2014-02-27715:23:15 ID:
Pae 1 of 8
Reg: 214-N0014196A-000000000-0000 Registration Date/Time: 2014/02/27 18:26:54 HERS Provider: CalCERTS, Inc
Electronipally Fifled by Joan D. Hacker and Authenticated at CalCERTS.Com - 2/27/2014
Electronically Signed at CalCERTS.com by Michael Jeha (Michael Jeha Construction) 3/5/2014
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Elliott Residence
Building Type 0 Single Family 0 Addition Alone
0 Multi Family 0 Existing+ Add tion/Alteration
Date
2127/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complie3 based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 3,602.0 ft2 Covered Slab Floor, 3.500" thick at Whole House
HIGH MASS Design - Verify Thermal Mass: 3,000.0 ft2 Exposed Slab Floor, 3.500" thick at Whole House
HIGH MASS Design - Verify Thermal Mass: 1,291.0 ft2 Covered Slab Floor, 3.500" thick at Casita
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix R44.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System BDP CO. 563AN048-A includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the
correct Condenser.
The HVAC System Whole House includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.59 w/cfm.
The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System Whole House includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System.
The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that
duct leakage meets the specified criteria.
The Cooling System BDP CO. 563AN036-A includes credit for a 11.0 EER Condenser. A certified HERS rater must i+eld verify the installation of the
correct Condenser.
The HVAC System Casita includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm
The HVAC System Casita incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System Casita includes credit for verified adequate airflow. A certified HERS rater must diagnostically maasure airflow of the HVAC
System.
The HVAC System Casita incorporates HERS verified Duct Leakage. HERS field verification and diagnostic test; g'is requi�ed to verify that duct
leakage meets the specified criteria. - ,-1 , j 1�f
f F arc CONSTRUCTION
r
t
Ener Pro 5.1 by Ener Soft User Number. 2655 RunCode: 2014-02-27T15:23:15 ID: Page 2 of 8
Reg: 214-N0014196A-000000000-0000 Registration Date/Time: 2014/02/27 18:26:54 HERS Provider: Ca10ERTS, Inc
Electroni,:.ally Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 2/27/2019
Electronically Signed at Ca10ERTS.com by Michael Jeha (Michael Jeha Construction) 3/5/2014
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type 53 Single Family 0 Addition Alore
Date
Elliott Residence
1 0 Multi Family O Existing+ Addition/Alteration
1212712014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 2.23 3.77 -1.54
Space Cooling 45.36 42.60 2.76
Fans 8.88 9.37 -0.49
Domestic Hot Water 4.62 5.20 -0.58
Pumps 0.00 0.00 0.00
Totals 61.10 60.94 0.16
Percent Better Than Standard: 0.3
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,020 290
Fuel Available at Site: Natural Gas (E) 1,150 355
Raised Floor Area: 0 (S) 1,650 797
Slab on Grade Area: 7,893 (149 910 257
Average Ceiling Height: 10.8 Roof 7,893 0
Fenestration Average U -Factor: 0.59 TOTAL: 1,699
Average SHGC: 0.40 Fenestration/CFA Ratio: 21.5%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
2/27/2014
Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signed Date
The individual with overall design responsibility hereby certifies_that the.proposed building design -represented in this set
of construction documents is consistent with the other compliance forms,and worksheets; with, the specifications, and
with any other calculations submitted with this permit application; and recognizes.that compliance+using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality,'and building "en� pe(sealing require
installer testing and certification and field verification by an approved HERS rater. ( y ', ' 17-
_Designer
Designeror Owner (per Business & Professions Code) f u, t COiNST RUCTIGN
Company Ochoa Design Associates
Address Name DA I E - -BY----
City/State/Zip Palm Desert, Ca 92260 Phone 760-773-6605 Signed License # Date
Ene Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2014-02-27715:23:15 ID: Page 3 of 8
Reg: 219-N0014196A-000000000-0000 Registration Date/Time: 2019/02/27 18:26:59 HERS Provider: CalCERTS, Inc
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 2/27/2014
Electronically Signed at CalCERTS.com by Michael Jeha (Michael Jeha Construction) 3/5/2014
CERTIFICATE OF COMPLIANCE: Residential (Part,4 of 5 CF -1 R
Project Name
Elliott Residence
Building Type m Single Family ❑ Addition Alore
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2127/2014
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation
CavitO Exterior Frame Interior Frame Azm
Joint Appe idix
Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC4
Azm Status Glazing Type
Location/Comments
17
Window 9.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
18
Window 9.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
19
Window 54.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
20
Window 4.5
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
21
Window 3.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
22
Window 3.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
23
Window 3.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
24
Window 24.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
25
Window 24.0
0.590 NFRC
0.40 NFRC 90 New
IWC 6200 Alum/Low-E
Whole House
26
Window 48.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
27
Window 6.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
28
Window 24.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
29
Window 48.0
0.590 NFRC
0.40 NFRC 180 New
IWC 6200 Alum/Low-E
Whole House
30
Window 24.0
0.590 NFRC
0.40 FRC 180 New
IWC 6200 Alum/Low-E
Whole House
31
Window 23.0
0.590 NFRC
0.40 FRC 180 New
!NFRC
IWC 6200 Alum/Low-E
Whole House
32
Window 21.3
0.590 NFRC
0.40 180 New
IWC 6200 Alum/Low-E
Whole House
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Wit I Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
17
Bug Screen
0.76
4.0 5.0 2.0 0.1
2.0 2.0
18
Bug Screen
0.76
4.0 2.5 2.0 0.1
2.0 2.0
19
Bug Screen
0.76
9.0 6.0 2.0 0.1
2.0 2.0
20
Bug Screen
0.76
3.0 1.5 2.0 0.1
2.0 2.0
21
Bug Screen
0.76
3.0 1.5 2.01 0.1
2.01 2.0
22
Bug Screen
0.76
3.01 1.5 2.0 0.1
2.0 2.0
23
Bug Screen
0.76
3.0 1.0 2.0 0.1
2.0 2.0
24
Bug Screen
0.76
8.0 3.0 2.0 0.1
2.0 2.0
25
Bug Screen
0.76
8.0 3.0 2.0 0.1
2.0 2.0
26
Bug Screen
0.76
8.0 6.0 10.0 0.1
10.0 10.0
27
Bug Screen
0.76
3.0 2.0 10.0p 0.1
10.0 10.0
28
Bug Screen
0.76
8.0 3.0 10.0 0.1
10.0 10.0 ,
29
Bug Screen
0.76
8.0 6.0 10.0 0.1
10.0 10.0
30
Bu Screen
0.76
8.0 3.0 10.0 0.1
10.0 .10.0 . ; �; , , U •\'
31
18ug Screen
1 0.76
8.0 2.9 2.0 0.1
2.0 2.0
32
IBug Screen
0.76
8.0 2.8 2.0 0.1
2.0 2.0
BY
�
Ener
Pro 5.1 by EnergySoft
User Number: 2655
RunCode: 2014-02-27T15:23:15 ID:
Page 5 of 8
Reg: 214-N0014196A-000000000-0000 Registration Date/Time: 2014/02/27 18:26:54 HERS Provider: CalCERTS, Inc
Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 2/27/2014
Electronically Signed at CalCERTS.com by Michael Jeha (Michael Jeha Construction) 3/5/2014
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Elliott Residence
Building Type 0 Single Family 0 Addition Alone
0 Multi Family 0 Existing+ Addition/Alteration
Date
1212712014
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGC
Azm Status Glazing Type Location/Comments
49
Window 8.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
50
Window 11.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alurnkow-E Casita
51
Window 11.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
52
Window 11.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
53
Window 8.0
0.590 NFRC
0.40 NFRC 0 New IWC 6200 Alum/Low-E Casita
54
Window 48.0
0.590 NFRC
0.40 NFRC 90 New IWC 6200 Alum/Low-E Casita
55
Window 48.0
0.590 NFRC
0.40 NFRC 180 New IWC 6200 Alum/Low-E Casita
56
Window 48.0
0.590 NFRC
0.40 NFRC 270 New IWC 6200 Alum/Low-E Casita
57
Window 48.0
0.590 NFRC
0.40 NFRC 225 New IWC 6200 Alum/Low-E Casita
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
-HqA 7Wd
Ove hang Left Fin Right Fin
Len H t I -Ext RExt Dist Len H t Dist Len H t
49
Bug Screen
0.76
4.0 2.0 2.0 0.1 2.0 2.0
50
Bug Screen
0.76
5.5 2.0 2.0 0.1 2.0 2.0
51
Bug Screen
0.76
5.5 2.0 2.0 0.1 2.0 2.0
52
Bug Screen
0.76
5.5 2.0 2.0 0.1 2.0 2.0
53
Bug Screen
0.76
4.0 2.0 2.0 0.1 2.0 2.0
54
Bug Screen
0.76
8.0 6.0 2.0 0.1 2.01 2.0
55
Bug Screen
0.76
6.8 6.0 2.0 0.1 2.0 2.0
56
Bug Screen
0.76
6.8 6.0 2.0 0.1 2.0 2.0
57
Bug Screen
0.76
8.0 6.0 10.0 0.1 10.0 10.0
i
' w
Ener
Pro 5.1 by EnerqySoft
User Number. 2655
RunCode: 2014-02=277'15:23:15 ID: Page 7 of 8
Reg: 214-N0014196A-000000000-0000 Registration Date/Time: 2014/02/27 18:26:54 HERS Provider: CalCERTS, Inc
Electronically Filed by Joan D. Hacker and Authenticated at Ca10ERTS.com - 2/27/2014
Electronically Signed at CalCERTS.com by Michael Jeha (Michael Jeha Construction) 3/5/2014
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Elliott Residence
Building Type ® Single Family ❑ Addition Aloie
❑ Multi Family ❑ Existing+ Acdition/Alteration
Date
1212712014
BUILDING ZONE INFORMATION
System Name
Floor Area ft
Zone Name New Existinq Altered Remcved Volume
Year Built
Whole House Whole House 6,602
72,622
Casita Casita 1,291
12, 910
Totals 7,893 r-01 0
HVAC SYSTEMS
-o
System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type
Status
Whole House
4 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback
New
Casita
1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
System Name
Duct
Heating Cooling Duct Location R -Value
Ducts
Tested?
Status
Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0
0
New
Casita Ducted Ducted Attic, Ceiling Ins, vented 8.0
0
New
13
WATER HEATING SYSTEMS
S stem Name
aty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
_oss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
A. 0. SMITH FPS -40-224
2
Small Gas All
Pipes Ins
42,000
40
0.62
n/a
n/a
New
A. 0. SMITH FPS -50-224
1
Small Gas I
No Pipe Insulation 1
43,0001
50
0.62 1
n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
ft
=
0
c
.
- " i 't-
S stem Name
'Pi
L'en th
Pip Pipe
Diameter
Insul.
Thick.
O HP
Plenum
Outside Buried
❑
av
I ,-
EnergyPro 5.1 by Ener Soft
User Number. 2655 RunCode: 2014-02-27T15i23 15 ID:
Page 8 of 8
Reg: 214-N0014196A-000000000-0000 Registration Date/Time: 2014/02/27 18:26:54 HERS PrDvider: CalCERTS, Inc
Sladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0841
6782 Stanton Avenue, Suite A, Buena Pari-, CA 90621 (714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778
March 20, 2014 Project No. 544-13081
14-03-109
Ochoa Design Associates
73-626 Highway 111
Palm Desert, California 92260
Project: Proposed Elliott Residence
80,559 Via Pessaro
The Hideaway
La Quinta, California
Subject: Foundation and Grading Plan Review
Ref: Geotechnical Update prepared by Sladden Engineering dated April 11, 2313; Project
No. 544-13081, Report No. 13-04-130
As requested, we have reviewed the Precise Grading Plans prepared by McGee Surveying, Inc.
along with the Foundation Plans and Details prepared by Satish Shah & Associated Inc. The
plans reviewed were prepared for the custom residence to be constructed at 80-559 via Pessaro
located within the Hideaway development in the City of La Quinta, California. Based on our
review, it is our opinion that the recommendations provided in the above referenced
Geotechnical Update as well as the previous geotechnical reports have beer properly
incorporated into these plans.
..-If-you have,quiesti'Ons'-'regarding tthis -memo br the above referenced'report; plei�se,'cohtact''the
undersigned.
Respectfully submitted,
SLADDEN ENGINE G
`,
R
�w0
BRETT L. D R30N
v✓��,'�
Brett L. Anderson , No. 5389
Principal Engineer w Exp. 9130114
S
ENGINEERING.,
Letter/gvm
0 C
Copies: 2 / Ochoa Design Associates
CM ®V LA gUINTA
,fWMWY DEVELO"4ENT
is
SATISH SHAH & ASSOCIATES, Inc.
CONSULTING ENGINEERS
3920 E. Coronado Street, Ste. # 203 Anaheim, CA 92807
PHONE: (714)632-1865 FAX: (714) 632-1314
E -Mail: sshahinc@sbcglobal.net
March 19, 2014
City of La Quinta
California
Building and Safety Department
Subject: Truss Layout and Calculations
BY: Foxworth Galbraith Lumber
Date 3-11-14
Project: Elliot Residence
80-559 via Passaro
Dear Plan Examiner:
Our office reviewed the Roof Truss Layout and Calculations prepared by Armour. Engineering,
and the layout and calculations are in substantial compliance with structural design.
Do not hesitate to call our office, for questions regarding this.
Thank You,
Satish Shah P.E.
�'�y�W STA
FOR CON'B--`UGT,'G V
BY\
1
DATE
Sladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863.0713 Fax (760) 863084
6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523.0952 Fax (714) 523-1365,
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845.8863
800 E. Florida Avenue, Hemet, CA 92543 (951) 766.8777 Fax (951) 766.8778
June 12, 2013
Ochoa Design Associates
73-626 Highway 111
Palm Desert, California 92260
Project: Proposed Custom Residence
80-559 Via Pessaro — Lots 304 & 305
The Hideaway
La Quinta, California
Subject: Soluble Sulfate Content
Project No. 544-13081
13-06-201
Ref: Geotechnical Update prepared by Sladden Engineering dated April 11, 2:713; Project
No. 544-13081, Report No. 13-04-130
As requested, we have sampled the surface soil on the subject lot to determine the soluble sulfate
content as it relates to selecting appropriate concrete mix designs. Testing indicates :hat the site
soil is generally considered non -corrosive with respect to concrete. The testing indicated a
soluble sulfate content of 800 ppm (0.080 percent) that corresponds with "negligible" exposure
category in accordance with Table 3 of ACI 318-08 Chapter 9. In accordance with ACI 318-08,
special sulfate resistant concrete mix designs should not be required.
If you have questions regarding this letter or the referenced reports, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEERING
BRUT L. `
ANDERSON
Brett L. Anderson ��
Principal Engineer w E CIVIL
ENGINEERING
SER/gvm
Copies: 4/Ochoa Design Associates
,may 'I P
v
MAR 242014
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Sudden Engineering
8782 Stanton Ave., Sufte A, Buena Park, CA 90821 (714) 5230952 Fax(714)523-1369
45090 Golf Center Pkwy, Sufte F, Indio, CA 92201 (760) 863-0713 Fax (760) 883.0847
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8x63
Date: June 12, 2013
Account No.: 544-13081
Customer. Ochoa Design Associates
Location: The Hideaway, 80559 Via Pessaro, Lots 304 & 305, La Quinta
Sulfate Series
Analytical Report
Soluble Sulfates
per CA 417
PPM
Soluble Chloride
per CA 422
PPM
800 250
DATE BY--
TABLE 19=A-2—REQUIREMENTS FOR SPECIAL EXPOSURE CO.NDRIONS
__ — .. -.
��.. ..-.... iia VVL•1.,
IIV lRJ
MINIMUId l�,
MAXIMUM
NOR94AL-WEIGHT Aim .
LIGHTWEIGHT
AGGREGATE
CONCRETE
1,taximum2Water.
CamentllloUs
6t6tariala•: Ratio; by'.
Wd' ht.
Noimal WefpFit
Aggregate
Concrete
f" Normal.
Aight and
. L10twalght
Aggregate
Concrete, pstt
WATMCEMEf(tMOU5
LIGKI)YEIGHT. -
SULFATE (SO4)IN
WATER. pprK
0-150
CEMPJ{TTYPE
z D.t10889*for MFa
MATERIALS',RATIO;'eY::
AGGREGATECONCRETE,
O.IO 0.20
150.1,500
EXPOSURE CONDMONAGGREGATE
WEIGNT,'NORMAL-WEIGHT
CONCRETE
4,000
x 0.00889 for MPo
0.20-2.00
Over 200
materiais
Concrete intended to have low permeability whs;n
,
0.45
0.45
4,500
exposed to water
Concrete exposed 10 freezing and thawing in a moist
0.50
4,000
condition or to deicing chemicals
For corrosion pro(ection for reinforced concrete
0.45
4,500.
exposed to chlorides from deicing rhemicals, salts or
'water,
brackish Orspray•fram these sources
0.40
51000
TABLE 19-A-3—REQUIREMENTS;FOR,CONCRETE
EXPOSED TO SHI FGTPJ1rVJTAIUIKIr1.prN1.1 „-,,,.
against cortosion'of embtddcd items or heczi "'b"— and th4 wiimaY =required for low permcibilityor forprotect on
Zseawater g (Table 19=A-2).
3Pozzolan that has been determined by test or swice record to improve sulfate rrsistanee when used in concrete con.
tsiriing iypc V cement. _
2-264
Fc.'i ca,s RUC V iON
DATE BY.
__ — .. -.
��.. ..-.... iia VVL•1.,
IIV lRJ
NORMAL -WEIGHT
AGGREGATE
LIGHTWEIGHT
AGGREGATE
CONCRETE
1,taximum2Water.
CamentllloUs
6t6tariala•: Ratio; by'.
Wd' ht.
Noimal WefpFit
Aggregate
Concrete
f" Normal.
Aight and
. L10twalght
Aggregate
Concrete, pstt
SULFATE
EXPOSURE
Negligible
WATER- SOLUELE
SULFATE
ISO�I1.INSOIL,
PERCEHTAGEBY
WEIGHT
0.00-0.10
SULFATE (SO4)IN
WATER. pprK
0-150
CEMPJ{TTYPE
z D.t10889*for MFa
ModerateZ
O.IO 0.20
150.1,500
II, IP(MS). IS
(MS)
'0.50•
4,000
Severe
Very scvctt
IA lowerwatcr-eerncndtious
0.20-2.00
Over 200
materiais
1.500.1'0,000
Over 10,000
rartn nr
V
pouolus
0.45
0.45
4,500
4,500
against cortosion'of embtddcd items or heczi "'b"— and th4 wiimaY =required for low permcibilityor forprotect on
Zseawater g (Table 19=A-2).
3Pozzolan that has been determined by test or swice record to improve sulfate rrsistanee when used in concrete con.
tsiriing iypc V cement. _
2-264
Fc.'i ca,s RUC V iON
DATE BY.
Sladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 525-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778
April 11, 2013
Ochoa Design Associates
73-626 Highway 111
Palm Desert, California 92260
Project: Proposed Custom Residence
80-559 Via Pessaro — Lots 304 & 305
The Hideaway
La Quinta, California
Subject: Geotechnical Update
Project No. 544-13081
13-04-130
Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated
September 22, 2000; File No. 07117-10, Report No. 00-09-772
Report of Testing and Observation During Rough Grading prepared by ESS dated
August 28, 2002; File No. 07117-11, Report No. 01-07-718
Report of Testing and Observation During Rough Grading preparad by Sladden
Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647
As requested, we have reviewed the above referenced geotechnical reports as they relate to the
design and construction of the proposed custom residence. The project site is lccated at 80-559
Via Pessaro (identified as Lots 304 & 305) within the Hideaway Golf Club development in the
City of La Quinta, California. It is our understanding that the proposed residence will be a
relatively lightweight wood -frame structure supported by conventional shallow spread footings
and concrete slabs on grade.
The subject lot was previously graded during the rough grading of the Hideaway project site and
was subsequently regraded. The rough grading included over -excavation of the native surface
soil along with the placement of engineered fill soil to construct the building pads.. The regrading
included processing the surface soil along with minor cuts and fills to construct the individual
building pads to the current configurations. Some additional over -excavation was performed in
areas where the building envelopes were reconfigured. The most recent ,;:ite grading is
summarized in the referenced Report
prepared by Sladden Engineering along
The referenced reports include recom:
structure foundations. Based upon our
structural values included in the refer
remain applicable for the design ar
foundations.
'ing—and_Qbservations During rough Grading
Ncompac�►ton te- st results.
LD"� dt;� �.
ns y ertaining to the construction of residential
f the4 efere'n6�repoxDt , it is our cpinion that the
aqi ng eport pieparedPpy Sladden Engineering
_ f the roposed restdm "
YIT BY Romm-COVED
MAR 2'0 2014
CIYY OF LA QUIINYA
~%amamewrry nWFLf9PMEhjT
April 12, 2013
-2-
Project No. 544-13081
13-04-130
Because the lot has been previously rough graded, the remedial grading required at this time
should be minimal provided that the building falls within the previously established building
envelope. The building area should be cleared of surface vegetation, scarified and moisture
conditioned prior to precise grading. The exposed surface should be compacted to a minimum of
90 percent relative compaction is attained prior to fill placement. Any fill material should be
placed in thin lifts at near optimum moisture content and compacted to at least 90 percent
relative compaction.
The allowable bearing pressures recommended in the referenced grading repot prepared by
Sladden Engineering remain applicable. Conventional shallow spread footings should be
bottomed into properly compacted fill material a minimum of 12 inches below -owest adjacent
grade. Continuous footings should be at least 12 inches wide and isolated pad foctings should be
at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing
allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf
for each additional 1 foot of width and 300 psf for each additional 6 inches ofi depth may be
utilized if desired. The maximum allowable bearing pressure should be :000 psf. The
recommended allowable bearing pressures may be increased by one-third for wind and seismic
loading.
Lateral forces may be resisted by friction along the base of the foundations and passive resistance
along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is
recommended for use in design. Passive resistance may be estimated using an equivalent fluid
weight of 300 pcf. If used in combination with the passive resistance, the frict=oval resistance
should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is non -expansive and falls within the "very low" expansion category in
accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and
reinforcement should be determined by the structural engineer. We recommend a minimum
floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs
to ensure that reinforcement is placed at slab mid -height.
Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder
consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equi-alent. All laps
within the membrane should be sealed and at least 2 inches of clean sand should be placed over
the membrane to promote uniform curing of the concrete. To reduce the potentia_ for punctures,
the membrane should be placed on a pad surface that has been graded smooth without any sharp
protrusions. If a smooth surface can not be achieved by grading, consideration should be given to
placing. a 1 -inch thick leveling course of sand across the pad surface prior to placement of the
membrane.
Based on our field observations and understanding of .local,,geol0gic conditions? the soil profile
type judged applicable to this site is SD, generally, describ6d1as stiff -soil The�foll swing presents
additional coefficients and factors relevant to seismic mitigation, for newt onstruct-on based upon
the 2010 California Building Code (CBC).
BX
.__
April 12, 2013 -3- Project No. 544-13081
13-04-130
The seismic design category for a structure may be determined in accordance w:th Section 1613
of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate
design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are
summarized below.
Occupancy Category (Table 1604.5): II
Site Class (Table 1613.5.2): D
Ss (Figure 1613.5.1):1.50g
S1 (Figure 1613.5.1): 0.60g
Fa (Table 1613.5.3(1)):1.0
Fv (Table 1613.5.3(2)):1.5
Sms (Equation 16-36 (Fa X Ss)): 1.508
Sm1 (Equation 16-37 (Fv X Si)): 0.90g
SDS (Equation 16-38 (2/3 X Sms)):1.00g
SW (Equation 16-39 (2/3 X Sm1)): 0.60g
Seismic Design Category: D
If you have questions regarding this letter or the referenced reports, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEEI
BRETT L.
r. DERSON
Brett L. Anderso y No.
Principal Engineer U-3 Exp. 9130114
CIVIL
ENGINEERING
SER/gvm `rlgl Q
F FC �F
Copies: 4/Ochoa Design Associates
C1
rvq
QUA LQr Cd.1SAo 21-1y CEPT
Fps-? CC STRUC for i�.
DATE
LA QUINTA
Please verify that soils reports contain all of the above information. in addition, to assure
continuity between the investigation/reporting' stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then can we be assured that the construction
documents address all of the site soil conditions.
La Quinta Geotechnical Report Checklist
Does the "Conclusions and Recommendations" section of the reporl address each of the
following criteria?
"Address" means:
(a) the criterion is considered significant and mitigation measure(s) noted, or;
(b) the criterion is considered insignificant and explicitly so stated.
Yes No Criterion
. ❑ Foundation criteria based upon bearing capacity of natural or compacted soil.
❑ Foundation criteria to mitigate the effects of expansive soils.
❑ Foundation criteria based upon bearing capacity. of natural or compacted soil.
0 Foundation criteria to mitigate the effects of liquefaction.
❑ Foundation criteria. to mitigate the effgcts of seismically induced differential
settlement.
❑ Foundation criteria to mitigate the effects of long-term differential settlement.
❑ Foundation criteria to mitigate the effects of varying soil strength.
❑ Foundation criteria to mitigate expected total and differential settlement.
Any "No" answers to the above checklist should be noted as specific required
corrections._
# # #��r��uaZ'�
DATE-` BY