Loading...
BWFE2015-023378-495 CALLE TAMPICO Twit D -` Qumr(v LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BWFE2015-0233 Owner: Property Address: 80559 VIA PESSARO STEVEN ELLIOTT APN: 777160039 221 CALDWELL AVE Application Description: HIDEAWAY / ELLIOTT / 230LF OF 6' BLOCK WALL (5) SECTIONS LOS GATOS, CA 0 Property Zoning: Application Valuation: $16,000.00 Applicant: MICHAEL JEHA CONSTRUCTION 41479 RESORTER BLVD UIT 27-12 PALM DESERT, CA 92211 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class : B icense No.: 410408 Date: -.2' contractor: U, OWNER -BUILDER DECLARATIO I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State license Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Contractor: MICHAEL JEHA CONSTRU 41479 RESORTER BLVD U PALM DESERT, CA 91211 (925)250-4038 Llc. No.: 410408 Date: 6/30/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have a 11 maintain a certificate cf consent to self -insure for workers' tio s provided for by Section 3700 a the Labor Code, for the performance cc)rr�pensa e or r which this permit is issued. I h ve and will maintain workers' compensation insurance, as required by Sect n 700 the Labor Code, for the performance of the work for which this permit is issueM orkers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ _ I certify that in the performance of th � work for which this permit is issued, I shall not employ any person in any manner so as -to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor C e-rSR8lTforth+ei'th comply witp those pr visions. Date Applicaht: WARNING: FAILURE TO SECURE WORKERS' COM?ENSA VERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINA, PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,0001 IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IV SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOW! EDGEMENT IMPORTANT: Application is hereby made to the 3uilding Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and stare that the above information is correct. I agree to comply with all city and county ordin antes and state laws relating to building construction, and hereby authorize representat.vesi?to enter upon the above: mentioned perty fl inspectio rposes. Date: ature (Applicant or Agent►: DESCRIPTION FINANCIAL .• ACCOUNT 1• QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE WALL/FENCE - EA ADDITIONAL 50 LF 101-0000-42404 0 $58.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $60.91 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forFENCE OR FREESTANDING WALL- TOTALS:00 $166.77 $0.00 Description: HIDEAWAY/ ELLIOTT / 230LF OF 6' BLOCK WALL (5) SECTIONS Type: WALL/FENCE Subtype: Status: UNDER REVIEW Applied: 6/30/2015 SKH Approved: Parcel No: 777160039 Site Address: 80559 VIA PESSARO LA QUINTA,CA 92253 Subdivision: TR 29894-2 Block: Lot: 305 Issued: Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $16,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories' 0 No. Unites: 0 Details: 230LF OF 6' GARDEN WALL AT (4) LOCATIONS UTILITY ENCLSURES AND (13) PILASTERS [ANGELUS SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES. ADDITIONAL SITES CHRONOLOGY FINANCIAL INFORMATION Printed: Tuesday, June 30, 2015 1:36:43 PM 1 of 2 NAAF CRUff SYSTEMS ON SEQID ;'INSP,ECTIOMTYPE'.-` INSPECTOR SCHEDULED COMPLETED RESULT .REMARKS . NOTES DATE DATE BOND BEAM BLD FINAL" BLD FOOTINGS I BLD PARENT PROJECTS REVIEWS REVIEW TYPE . ' REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS DATE NOTES BOND INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID . PAID DATE RECEIPT# CHECK# METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: WALL/FENCE - EA 101-0000-42404 0 $58.00 $0.00 ADDITIONAL 50 LF WALL/FENCE - FIRST 101-0000-42404 0 $47.86 $0.00 100 LF WALL/FENCE - FIRST 101-0000-42600 0 I $60.91$0.00 T 100 LF PC I Total Paid forFENCE OR FREESTANDING WALL* $166.77 $0.00 TOTALS:00 SEQID ;'INSP,ECTIOMTYPE'.-` INSPECTOR SCHEDULED COMPLETED RESULT .REMARKS . NOTES DATE DATE BOND BEAM BLD FINAL" BLD FOOTINGS I BLD PARENT PROJECTS REVIEWS REVIEW TYPE . ' REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS DATE NOTES Printed: Tuesday, June 30, 2015 1:36:43 PM 2 of 2 CRWYSTEMS BOND INFORMATION ATTACI IMCNTS Printed: Tuesday, June 30, 2015 1:36:43 PM 2 of 2 CRWYSTEMS Bin # City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # &W10, / Project Address: Ub P Owner's Name: A. P. Number: 7 Address: 6A,),, Legal Description: City, ST, Zip: Contractor:fP Tele hone: Address: y' Project Description: l i, t 1 City, ST, Zip: 3 Telephone: — i 2 State Lic. # : U D City Lic. #; Arch., Engr., Designer: Address: City, ST, Zip: Telephone: hone: Con tr s uction Type: Occupancy: Y P .anc Y: a i State Lic. #: Project hPa (circle one):.: New Add'n Alter Repairair Demo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: P Estimated Value of Project: �. (�(�u APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING P RMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2". Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 3" Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees ' Q aoq on •�o m `5 T Z m � , Z n EZ 7 4 DSITE REFS �a 9' CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED _ FOR CONSTRUCTION DATEO �� -4BY �v 9 r 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS 6' to 8' High Site Wall Trench Footing -CPT? ,90�pFE{PTA B*vmc Risk l ategOM'v J. St'FETY DEPT. ANGELUS BLOCK MASONRY FENCE WALL SYSTEM 6 ide POM -PROVED WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR FOR CONSTRUCTION DESIGN CRITERIA: / 1. DESIGN CRITERIA PER 2013 CBC 2. ALLOWABLE SOIL BEARING PRESSURE - 1500psf OPTIONAL WALL CAP DATE 3. ALLOWABLE SOIL PASSIVE PRESSURE - 150pcf = 4. COEFFICIENT OF FRICTION 0.25, COHESION Opsf 'X' BARS PER 5. CANTILEVER ACTIVE = 30pcf vvi 6. MASONRY COMPRESSIVE STRENGTH, f*m - 150OPe1. SPECIAL INSPECTION SCHEDULE 0 NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE CTR. OF WAIL PROJECT SPECIFIC SITE. 6 STD. LADDER TYPE. NOTES:p5 STD FOR $LUMPSTONE), JOINT REINF. AT TOP COURSE, 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 AT FIRST COURSE, AND 24"o.c. - GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 3'-0" 2'-4" INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD -DRAWN STEEL WARE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 6" WIDE (NOM.) CMU 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, GROUT CELLS 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500pel 0 28 DAYS, UNLESS w/ REINF. OTHERWISE REQUIRED BY SOILS REPORT. Tti 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS MASONRY FENCE WALL SCHEDULE BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR H' MAX. X BARS REINF.WALL STEM Y BARS 18' LONG CMU 18" LONG CMU TYPE PER S-2.0 16' LONG CMU 18' LONG CMU WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR D' MIN. 6'-0" o ANGELUS BLOCK SLUMPSTONE SHALL BE USED. ;A; B' loa = 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS 'X' BARS PER = vvi MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPORTIONS AND SCHEDULE 0 REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS CTR. OF WAIL lo W CL MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPERTY A' B' SETBACK 4018"o.c. 4054"o.c. REQUIREMENTS OF ASTM C270. 3'-0" 2'-4" PER 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, SCHEO. #4048"o.c. AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 'A' B 4016'o.c. 4048"o.c. 4018"o.c: 045"o.c. 'OOpsl. x 0,00 3'-2n 2'-5 QS 1 Y BARS PER 7. , iRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE SCHEDULE LAP 10 /4040"o.c. IS PLASTIC. PER 'L' 408"o.c. 4040"o.c. 409"o.c. 4036'o.c. 1 3'-4"3'-5" 2'-O" 2'-7- '-7' Z w 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. F.C. 00 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF w o. 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR WET -SET FIRST MORTAR WASHED COURSE 2. 10. GROUT ALL CELLS WITH REINFORCEMENT.1 D 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL 2-{#4 CONT. REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK-OUT DETAILS w SEE DETAIL SHEET S-5.1. CL MINIMUM DEPTH '0 0 SLOPE M SLOPESETBACK 01- 0' 1 -0 2 :1 2'-6" 2'-0 CONT. CONC. FTG. 8" ! 5'-0" MIN.'[ 3 :1 2'-O" CONT. TO DAYLIGHT 940'W MASONRY FENCE WALL SCHEDULE H' MAX. X BARS REINF.WALL STEM Y BARS 18' LONG CMU 18" LONG CMU TYPE PER S-2.0 16' LONG CMU 18' LONG CMU L' STEM D' MIN. 6'-0" x/4048"o.c. (14054"o.c. ;A; B' 4024ox. 4048"o.c. 4027"o.c. 4054"o.c. V-0 2'-0" 2 -10 6'-8" #4048"o.c. b4045"o.c. A' B' 4016"o. c. 4048"c.c. 4018"o.c. 4054"o.c. 2'-0" 2'-0" 3'-0" 2'-4" 7'-4" #4048"o.c. X4045"o.c. 'A' B 4016'o.c. 4048"o.c. 4018"o.c: 045"o.c. 3'-0" 2'-0 3'-2n 2'-5 /4040"o.c. #4036"o.c. A' 'B' 408"o.c. 4040"o.c. 409"o.c. 4036'o.c. 1 3'-4"3'-5" 2'-O" 2'-7- '-7' 9 0'W ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East Badilld Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 en91—&np exC 11-6. .Ince 2957" OF DATE SIGNED 6-25-14 S-1.2LQ #6255 8' High Max. Site Wall C o 100 mph 0*5L,Risk Category I ince Im ANGELUS BLOCK MASONRY FENC WALL SYSTEM 6' Wide CMIJ END OF WALL x O 5 x HF 5 [ �- •� ..f �i ti B 0.. • t A r '.-,i,h'. 0 x LLLor.g� x RVURN TYP.. 5 x HF 5 x HFA � ) 5.x HF TYPICAL REINFORCED WALL STEM TYPES PLAN WALL TYPES & TOTAL WALL LENGTH TYPICAL REINFORCED WALL STEM TYPES ELEVATION WALL TYPES l A 1 & t tS .I tl ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East Badillo Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 '•ena[n—fna excellence since 1957- _z-Ana-x�u.l-wv 5 x HF MIN, AT4491C 5-21-14 S-2.OLQ #6255 4SLOCKC�,IHC. shn I ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2013 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE - 150pcf (W/ INCREASE PER 1806.3.4) 4. COEFFICIENT OF FRICTION - 0.25, COHESION = Opsf 5. DESIGN CRITERIA MUST BE VERIFIED BY USER PRIOR TO USING THIS DETAIL, 6. MASONRY COMPRESSIVE STRENGTH, I'm - 1500psi. SPECIAL INSPECTION. NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE! PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60, PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. NOT USED 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR •SHOTBLAST, OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS' MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7 IST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE PLASTIC. 8. NOT USED 9. PROVIDE EXPANSION / CONTROL JOINT ON EACH SIDE OF PILASTER WHERE INTERSECTING BLOCK WALLS OCCUR. 10. NOT USED. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. OPTIONAL ADHERED VENEER (MAX WEIGHT-10psf) MAY BE APPLIED TO EACH FACE OF PILASTER. INSTALLATION BY OTHERS. MECHANICALLY -ANCHORED VENEER IS NOT PERMITTED. 13. 00 NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE LOADING 1. SEISMIC, 57. DAMPING 0 1 SECOND ACCELERATION Cs=0.33Wt. 2. SEISMIC LOADING EXCEEDS ALL WIND LOADING FOR EXPOSURE C, 120mph AND LESS. I 16816 OR 16616 CMU PILASTER, SOLID GROUT 1 1 0 6'-8" to 8'-8* High Pilaster Pole Footing - Seismic, 5% olsec - 16' or, 24" CMU Pilaster OPTIONAL WALL CAP — r CMU PILASTER, SOLID GROUT (16" SHOWN) 3j"OUTSIDE-FACE-- OF BLOCK TO — t OF VERT 2-#4 VERT. 2-#4 U-DWLS. - LAP 24" MIN, TYP. F.G. WET -SET FIRST !- COURSE 3-#3 TIES 0 TOP 5' OF FTG. & _ #3 TIES O 12"o.c. MAX. THROUGHOUT r^ 2-#4 U-DWLS. $- WIDE (NOM.) CMU PILASTER, SOLID GROUT ALL CELLS CENTER VOID OPEN OR SOLID -GROUT 'W =24" SO. A PILASTER SECTION ANDERSON DESIGN GROUP Structural Engineering Building Design 228 East 8adlllo Street • Covina • CA • 91723-2115 (626) 938-1595 • Facsimile (626) 938-0485 "s g1M r g excellence since 1957' 31" OUTSIDE FACE - OF BLOCK TO G. OF VERT FTG. SECTION B - — 3" CLR. TYP, 3-#3 TIES TOP 5" OF FTG. & #3 TIES O 12"o.c. MAX. THROUGHOUT 2-#4 U-DWLS. DATE SIGNED 6-25-14 S-1.10LQ #6255