Loading...
06-2588 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4ht 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: .06-00002588. Property Address: 80614 VIA PESSARO APN: 772-500-013- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 498367 Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under rovisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profes 'onals o e, and my License is in full force and effect. License Class: B L e e No.: 838041 ate: - ZO Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perj y hat I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Busi ss and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will.do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: BARBRO TAPER 81-205 KINGSTON LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/15/06 Contractor: D SOUTHERN HILLS DEVELOPMEN C 78150 CALLE TAMPICO STE 1 NOV 2 0 20106]1 LA QUINTA, CA 92253 (760)771-3497 Lic. No.: 838041 CITY OF LA QUINTA WORKER'S COMPENSATION DECLARATION I hereby, affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers'compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT _%0(_J certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subj 99t tot workers' compensation provisions of Section 3700 of the Labor Code, I sh rth 'Rt co pl with those provisions. a� ,ate k;cant: WARNING: FAILURE TO SECURE WO ERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMIN PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITIO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and ounty ordinances and state laws relating to building cons uction d hereby authorize representatives of th' ounty to enter upon thea ve-mentioned property for in on rpos ate: Sig ure (Applicant or Agent): Application Number . . . . . 06-00002588 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 2036.00 Plan Check Fee 1323.40 .Issue Date . . . . Valuation . . . . 498367 Expiration Date 5/14/07 Qty Unit Charge Per Extension BASE FEE 639.50 399.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,00i-SUU,000 1396.50 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 178.00 Plan Check Fee 44.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/14/07; Qty Unit Charge Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE <=100K 45.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1:00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 4.00 9..0000 EA MECH B/C <=3HP/100K BTU 36.00 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 219.16 Plan Check Fee 54.79 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/14/07 Qty Unit Charge Per Extension BASE FEE 15.00 5630.00 .0300 ELEC NEW RES -.MULTI FAMILY 168.90 1013.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 20.26 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 245.25 Plan Check Fee 61.31 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/14/07 Qty Unit Charge Per Extension LQPERMIT Application Number . . . . . 06-00002588 Permit . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 27.00 6.0000 EA PLB FIXTURE 162.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 4.00 3.0000 EA PL13 UA6 PIPE 1-4 OUTLETS 12.00 9.00 .7500 EA PLB GAS PIPE >=5 6.75 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00' Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 5/14/07 Qty Unit Charge, Per Extension BASE FEE 15.00 ---------------------------- ------------------------------------------------- Special Notes and Comments. 5,630SF DWELLING/V-NR/RES-3. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS, POOL AND SPA, OR DRIVEWAY APPROACH. November 6, 20062:40:55 PM AORTEGA ----------------------------------------------------7----------------------- Other Fees . . . . . . . ART IN PUBLIC. PLACES -RES 745.91 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 132.34 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 49.83 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged --------------------'------- Paid Credited ------------------------------ Due Permit Fee Total 2693.41 .00 .00 2693.41 Plan Check Total 1484..00 1000.00 .00 484.00 Other Fee Total 4639.08 .00 .00 4639.08 Grand Total 8816.49 1000.00 .00 7816.49 LQPERMIT ~� C&4 P.O. BOX 1504 Building 78-495 CALLE TAMPICO Address !� (i7�4' Y 17� Y IC�'i LA OUINTA, CALIFORNIA 92253 MailinAddress(?[ City zt7 Tel. Cgntractor "� � 1 b ro for f , Address ^^ y T" Ci " �Zi Tel. � �ZZ�3 State Lic. ; City & Classif. �� Q ?)� Lic. # Arch., } (, J �P Designerer b �_ �_�s °vV— 114e135 � bz/d'� Tel S01'T� C�IY Zip State L afJ�, �2Z.0 Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuantto the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct - the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not empoy any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit whenproperly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip o* - 2 68 6 APPLICATION ONLY BUILDING: TYPE CONST `� f� OCC. GRP. A.P. Number —112- 1] 2- 540 "— 6) Legal Description A (7 0 Tit� -4 e-9 4 Z Project Description �� l�n.f t� fI>IC�Y Sq. Ft. // No. _ _ No_Dw. Size �(O Stori Units New L Add ❑ P epair olition ❑ (i2006 11 FINANCE DEPT Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. 40 OF I V Infrastructure LA I OWE TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback `rom Center Line Side Setback from P`operty Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE NOV-07-2006—TUE 12:10 PM ORANGE COAST TITLE FAX No.7605685184 P•002 WHEN RECORDED MAIL T0: Wells Fargo Bank 1350 Fashion Valley Road, 3rd Floor San Diego, CA 92109 MAIL TAX STATENIENT TO: SAME AS ABOVE -tF.R'. 0W DOCUMENT TRANSFER TAX S 577.50 XX Computed on the consideration or value of property conveyed; OR DOC ti= 20D3-99020 i2/1612o a 011:060 FRe a6.se Pape t of 9 Dee T Tau'Pald' Recorded In Official, Records county of Rlveraide Gary L. Orac kneasor, County Clark 8 Recorder' 11121�1I R111�111151112II Computed on the consideration or value less Bens or encumbrances rettlaining at the time of sale. LdJ Signature of Declarant or Agent determining tax — FitmlVame GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company C%rantor'0; hereby GRANT(S) to Barbro Taper and tells Fargo Bank, /CO -Trustees 'of TRY' BARRY •8. TAPIR TRUST #3 N.A. as C'Grantee'), the real property located in the City of La Quint&, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A": SUBJECT TO all matters of record including; without limitation, the covenants and agreements descn'bed in Exhibit "A"' attached hereto. Dated: 12/9/03 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited liability comp y its managing er - osep L. Amson Authorized Representative Description: Riverside, CA Document-Year.DoclD 2003.989020 Page.- 1 of 5 Order., ED -11-07-200611-26-49 AM Comment.` - "man H,-.t' i coot .aie eaWo : uaa Computed on the consideration or value less Bens or encumbrances rettlaining at the time of sale. LdJ Signature of Declarant or Agent determining tax — FitmlVame GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company C%rantor'0; hereby GRANT(S) to Barbro Taper and tells Fargo Bank, /CO -Trustees 'of TRY' BARRY •8. TAPIR TRUST #3 N.A. as C'Grantee'), the real property located in the City of La Quint&, County of Riverside, State of California, described as: See Legal Description attached hereto and incorporated herein as Exhibit "A": SUBJECT TO all matters of record including; without limitation, the covenants and agreements descn'bed in Exhibit "A"' attached hereto. Dated: 12/9/03 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited liability comp y its managing er - osep L. Amson Authorized Representative Description: Riverside, CA Document-Year.DoclD 2003.989020 Page.- 1 of 5 Order., ED -11-07-200611-26-49 AM Comment.` - NOV-07-2006—TUE 12:10 PM ORANGE COAST TITLE FAX No.7605685184 P.003 STATE OF Calif rnis COUNTY OF _Riverside On December 9. 2003 before me, K. Larbv. Notary Public (Name, Title of Officer) personally appeared Jose_ hg L. Arenjgn personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(sl whose name(s) is/are subscribed to the within instrument and acknowledged to me that he:she/they executed the same in his/heritheir authorized capecity(ies), and that by his/her/their signatureks) on the Instrument the person(s), at the entity upon behalf of which the person(s) acted, executed the instrument. WITN7S7dfficial seal. . (Sign lure o o y Pu ic) ooee oMUL Smi. K. LMMY 0 com"Krzss y o wIUNNE is 2oos�' (This area for notarial sea)) Description: Riverside, CA Document-Year.DocID 2003.989020 Page: 2 of 5 Oiler. ED -11-07-200611-26.49 AM Comment: NOV-07-2006—TUE 12:10 PM ORANGE COAST TITLE FAX No,7605685184 P.004 i ! Leg_alDmaWtion EffLel S2, 1: Lot 171 (the "Lot') of Amended Tract No. 29894-2 as shown on Subdivision Map (the "Map") . recorded on December 12, 2002, in Book 327, Pages 56 to 88, inclusive, *of Maps, in the Office of the Riverside County Recorder. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer all Or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the fallowing instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrument No. 2002- 745939, of Official Records ofRiverside County, California (the "Official Records'); 2. The Supplementary Declaration of Annexation of Property, recorded on March 21, 2003, as Instrument No. 2003-201647, of Official Records of Riverside Country, Cali-:bmia. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirememts for the recordation of the Final Tract Mau, the grading of said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preoeded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied with by Grantee, Grantor may emfocce. this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. kURTkMR RESERVING THEREFROM, an easement for landscaping pwWses over the Southerly 11.5' feet thereof. , Parcel No. Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as.described in, the Declaration. DesWptbn: Riverside, CA Document Year.DoclD 2003.989020 Page: 3 of 5 Omer. ED -11-07-200611-26-49 AM Comment: I NOV-07-2006—TUE 12:10 PM ORANGE COAST TITLE FAX No.7605685184 P.005 SUBJECT TO: Non delinquent general, special and supplemental real property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-2. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway - Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable prorWons and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be perfowed by Grantee under the Declaration. The restrictions an use and occupancy of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING. granting unto Grantor and The Hideaway Owners Association such powers and rights which are set forth in the Declaration defined above, on 12 - Q = 0 3 - , 2003. as Barbro Taper adn Hells Fargo Bank` Co -Trustees of THE BARRY H. TAPER TRUST 83 well For o Bank Barbro Taper, Co -Trustee /g. STATE OF AA z2i) COUNTY OF,4 6 'ok I // ) On 2 mho Z_ 2003, before me, the undersigned, a notary public in and for said State, personally appesz+ed.SL 1h 9W51ftY known to me (or proved to me on the basis of satisfactory eviderw4to be the persons whose names are subscribed to the within instrument aid acknowledged to me that they executed the same in their authorized capacities, and that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. [SEAL] .t.,,.,�., ....c.e Signature Comm�ssbn� 1775+ Notary ftbrx - CaNamis Los Maoist Cosnty My commission expires. �rcornzn r�,rre6Notzr, sacs i Dewlpfon: Riverside, CA Document-Year.Doc1D 2003.989020 Page: 4 of 8 i Order. ED -11-07-200611-26-49 AM Comment- NOV-07-2006—TUE 12:10 PM ORANGE COAST TITLE FAX No,7605685184 SUBJECT TO: 1. Non delinquent general, special and supplemental real property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, easements, rights and rights-of-way of record including, without imitation, the Declaration and the Map for Tract No. 29894-2. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as arc set forth in. the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provit:ions and requirements set forth in the Declaration, inchtding Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set for -.h in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, gtanting :unto Grantor and The Hideaway Own e sociatiotn such powers and tights which are set forth in the Declaration defined above, on 2003, L arbro Taper, Trustee Wells Fargo Bank, Trustee STATE OF (7A L-1 QM cW ) • ) ss. COUNTY OF 1S tv4&s ilDe ) On nDe.J.�, - ,It.-&/ , 2003, before me, the undersigned, a notary public in and for said State, personally appeared Bsrrbro •Taper, personally known to we (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and acknowledged to rue that they executed the same in their authorized capacities, and that by their signature on the instrument the persons, or the entity upon behalf of v0hich the persons acted, executed the instrument. WITNESS MY HAND AND OFFICIAL SEAL. [SEAL] ignature , Description: Riverside, CA Document-Year.Doc/D 2003.989020 Page: 5 of 5 Order. ED -11-0T-2006 91-2649 AM Comment: P. 006 ConMe Concetto COMM. 01217229 N010V Pukoc ']t1Ui YA v, 08/03/2007 08:45 7603999785 FRANCO CONSTRUCTION PAGE 02/02 FROM SLADDEN PALM DESERT (FRO JUL 27_2007 12:03/ST.12:02/N;.6802770051 P 1 JCM Inspections =0725 Ganlnd Lane Suite F I N S r a C T t o N S Pglm Oestlrt, CA 92211 Phone: 760.346.6664 - Fss: 780-77241896 MINSP tr c :Ton s EPDXY INSPECTION REPORT Dow: oroJsse No: ProlM Address: 'N algam gala '1V.— t CI 1 CNsnt; aI b�p�• Su b Cata� E'mw StwN Ubt: Moo Clssnlno wthoWs). of wo t Inapetetr* iff 0 tt ❑rias 24 umnsotvied himc pmbft ❑ass Bstsw work CmPllstr with wrtftn spproasl born Strur hwM MWUW and ICC Eval wtlon FOopon; 0 honbY gory tM t Is",F nr a ria •Oow woAti unbq ogle wm nosed, and to the Met of my abity I aM tbund #0 Watt, to COM* wit dna e00w.ed 1332- 0Bn5, 1peCtbettelN jwP&m" bwL Ano toow&a" at Wvwdeemplift . InsPrrct0r. ` \ C. glllln I� O t No: 084221848 I cmeeletoes Rrpwwssnf vw: cow t JmpMrepfsona copy 2 pmkd Sup M*ndm C" C WMftAwnty Pvm.--•,Cr�— Certificate of Occupancy �w G� OFBuilding Y p & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-614 VIA PESSARO Use classification: SINGLE FAMILY DWELLING Building Permit No.: 06-2588 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: BARBRO TAPER Address: 81-205 KINGSTON HEATH City, ST, ZIP: LA QUINTA, CA 92253 By: STEVE TRAXEL �!b�t Date: FEBRUARY 28, 2008 Building Official POST IN A CONSPICUOUS PLACE TITLE 24 REPORT Title 24 Report for: Taper Residence 80 614 Via Pessaro La Quinta, CA 92253 Project Designer: Andrzej W. Weber Architect AIA 74 133 EI Paseo, Suite A Pala Desert, CA 92260 (760) 340-3002 I Report Prepared By: Wayne Seward, CEA R05-04-5184 Bear Technologys 7774 Calle Mejor Carlsbad, CA 92009 (760) 635-2327 Job Number: 6Q4051 Date: 11/6/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This p -ogram has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 604051 User Number: 5956 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary 1 2 3 10 12 13 EnergyPro 4.3 by EnergySoft Job Number: 6Q4051 _ __ User Number: 5956 Certificate Of Compliance : Residential ❑ Addition (Part 1 of 4) CF -1 R 1�pQr f3PsidPnre MasteLriedrooalZone ❑ Multi Family ❑ Existing + Add/Alt 1116,/ 006 Protect Title _80 14 Via Pessarn La Qiiinta--__ (S) 180 deg Raised Floor Area: Date Project Address _ - sLEloazZme Natural Gas Slab on Grade Area: Building Permit # Bear Teehrloloply$, Nea 01-A7 (760) 635-2327 Average Ceiling Height: plan Check'Date Documentation AuthoT- 1,413 ft' Avg. U: 0.33 Telephone 1.00 app -'15 25.4% Avg. SHGC: 0.25 Number of Stories: 2 Field Checl�/Date Compliance Method Climate Zone TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space. Heating 3.47 3.54 -0.07 Space Cooling 67.39 65.36 2.03 Fans 9.55 9.23 0.33 Domestic Hot Water 4.35 4.89 -0.54 Pumps _ 0.00 0.00 0.00 Totals 84.77 83.03 1.74 Percent better than Standard: 2.1% Building Type: W Single Family ❑ Addition Total Conditioned Floor Area: 5,556 ft' MasteLriedrooalZone ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft' Building Front Orientation: (S) 180 deg Raised Floor Area: 1,154 ft'Fuel Type: _ - sLEloazZme Natural Gas Slab on Grade Area: 4,402 ft' Fenestration: Nea 01-A7 2ndfloo-7one Average Ceiling Height: 11.6 ft Area: 1,413 ft' Avg. U: 0.33 Number of Dwelling Units:. 1.00 Ratio: 25.4% Avg. SHGC: 0.25 Number of Stories: 2 BUILDING ZONE INFORMATION # of Thermcstat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area JAeat Pimp _37 11 244 017 _--Conditioned--Sethark $ n/a JiYAC _ _ 4.619 53-M 0.83 Conditioned Setback OPAQUE SURFACES Insulation Act. Type _Frame_ Area U -Fac. Cay. Cont. Azm. Tilt RQaf__ Wood -_.q3Z- 0 036_ R_SQ_ _R-0 0_ 0 3 Wall_Wood- 276 -100 _R-219.0 a 90 Wall- .Wo9d-_ 3a -069 _R-21 _B _0_Q -90_90. Wall- WQnd _ 407 _0.069 X21 R-0 0 -270 90 Root- Wood 1.839 _ 0036. _1-30_ R -0A 0_ 32 Raaf- Wood- -1 62.6 _0..032 R -30X0..0_---0- 2Z Wa1L- Wood- 65D_ -Q 069 R_21 R-0-0 _0_x.0 Wail-_ WOQd__ --a5-0-A.069 _B21 0 A Wall_ Wood 5BB- -0 069_ -R2.1 _ R-0-0 -9.0_-90 Wall- Wood- 462 _0_062 R_21 -P-Q.0---J8D__90 Wall- Wond-- 6= 006 _ X21 _-R-Q.D_ _2Z0__9 Roof - Wood__ 1 -94- _0.019 -R-30 R-0 0_ -0__22 \Nall Waod_ _3.3.8_ -0.069 R_21 R-0.0 0-9.0 Wall.-- Wood- --505_ _0.069 -R-21-R-Gk _-20 90 Wall- Wand- 2J9- -0..Q69 R-2 - -R-(LO- _SBD 90 Wall_ WaQd_ 494 0.069 R-21 -R--(LO- 270 90 f_IooL- Wood 1 154 _Q -Q48_ 13_1,9--R--Da �_ 180 Gains Condition Y / N Status JA IV Reference Location / Comments New 02-A9 Mqster_[iedroom Zone New 09-A6 Master Bedroom Zone New 99-A6 MasteLriedrooalZone New - 09-A6 Mast .r SRAkoQn2 Zone New 02_A9 1c_t FlocrZone_._ Rew 01-A7 1st Floe Zone New 09-A6 lct FIQQ Zone New 99-A6 _ - sLEloazZme New 99-A6 1st -Boca one__ New 99-A6 Pleas-- -Q9--A6.-- 1st FIoQZap-e-_ 1st FIocLZone - Nea 01-A7 2ndfloo-7one New _ 09-A6 2nd -Floor Zone _ New 09-A6 2nd A Zone New 09-A6 NBA -99-A6 New 21-A4 _ 2nd-Elo27one 2nd Flo¢ZQne 2nd FIocrZone _ Run Initiation Time: 11/06/06 19:25:16 Run Code: 1162869916 EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 604051 Page:3 of 14 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Taper Residence _ 11/6/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazinq Tvpe Comments J- W.Iridow Bear (b)_ 14 J. -0-330 NEK- .4.25 _NEBC 0 -9Q New NonMtll Air Filled i as eLBp-drzomZoIle__ 2 Window Rear (N) 30.0 0.330 NFRC 0.25 NFRC 0 90 New NonMtll Air Filled Master Bedroom Zone 3 . Window Rear (NL 10.0 0.330 NFRC 0_25 NFRC _ 0 90 New NonMtll Air Filled Master Bedroom Zone 4 Window Rear (N) 14.1 0.330 NFRC 0.25 NFRC 0 90 New NonMtll Air Filled Master Bedroom Zone 5 Window Rear (N) 48.0 0.330 NFRC 0.25 NFRC 0 90 New NonMtll Air Filled _ Master Bedroom Zone 6 Window Right (E) 48.0 0.330 NFRC 0`25 NFRC 90 90 New NonMtll Air Filled Bedroom Zone _ 7 Window Left (W)_ 10.0. 0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled _Master Master Bedroom Zone 8 Window Left (W) 9.8 0.330 NFRC 0.25 NFRC 270 90 New NonMtll Air Filled Master Bedroom Zone 9 _Window Left (W)_ 12.9 0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled Master Bedroom Zone _ -10 Window Rear (N) _ 20 6 0,330FRFRQ 0.25 NFRC 0 -3 New NonMtll Air Filled 1st Floor Zone 11 _Window Rear (N) 48.0 0.330 NFRC _0.25 NFRC 0 90 New NonMtll Air Filled 1st Floor Zone 12 Window Rear (N) 47.5 0.330 NFRC 0.2_5 NFRC 0 90 New NonMtll Air Filled 1st Floor Zone 13. -MLdQ Rear - -29-6 0.33 NFRQ QM NFRC 0_ 90 New NonMtll Air Filled _]StFloor Zone 14 Window Rear (N) 25.0 0.330 NFRC 0_25 NFRC 0 90 New NonMtll Air Filled 1st Floor Zone _ 15 _Window Rear (N)_ 25.1 0.330 NFRC 0_25 NFRC 0 90 New NonMtll Air Filled 1st Floor Zone 16 _Window Rear (N) 126.0 0.330 NFRC 0.25 NFRC 0_ 90 New NonMtll Air Filled 1st Floor Zone 17 Window Right E 7.8 0.330 NFRC 0_25 NFR • 90 90 New NonMtll Air Filled 1st Floor Zone 18 _Window Right (E) 7.8 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 1st Floor Zone 19 Window Right (E) 7.8 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled _ 1st Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type _ SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen _ 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 S Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen__ 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 _ 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen _ 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type Length R -Val. Location JA IV Reference Slab Perimeter 79 Slab Perimeter 260 Condition Location/ Status Comments Insulation 26-A1 New _ Ma; Insulation 26-A1 New 1st L EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 604051 Paae:4 of 14 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Taper Residence 11/6/2006 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 2Q ..JNind-aw Right (F) 7-8_ --0_33911EBC -0.25 NFRC _-90 21 _ 90 New NonMtll Air Fjued -J.stFloor Zone 21 Window Right (E) 4.0 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 1st Floor Zone 22. Window Right (E) 4.0 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 1st Floor Zone 23 Window Right (E) 18.5 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 1st Floor Zone 24 Window Rihg t (E_ 18.5 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 1st Floor Zone 25 Window Right (E) 48.0 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 1st Floor Zone 26 Window Front (S)_ 20.6 0.330 NFRC 0.25 NFRC 180 90 New NonMtll Air Filled 1st Floor Zone 27 Window Front (S) _ 48.0 0.330 NFRC 0.25 NFRC _ 180 90 New NonMtll Air Filled 1st Floor Zone 28, Window Front (S) 47.5 0.330 NFRC 0_25 NFRC 180 90 New NonMtll Air Filled 1st Floor Zone ,29 Window Front (S) _20.6 0.330 NFRC 0.25 NFRC 180 90 New NonMtll Air Filled 1st Floor Zone 30 Window Front S 6.3 0.330 NFRC 0_25 NFRC 180 90 New NonMtll Air Filled 1st Floor Zone 31 Window Front (S) 32.0 0.330 NFRC 0.25 NFRC 180 90 New NonMtll Air Filled 1st Floor Zone Wjndow Front (S) 27.1, 0.33 NFRC 0,25 NFRC 180 90 New NonMtll Air Filled 1st Floor Zone 33 Front (S) 27.1 0.330 NFRC 0.25 NFRC 180 90 New NonMtll Air Filled 1st Floor Zone 34 _Window Window Left (W) 6.0 _0.330 NFRC 0.25 NFRC 270 90 New NonMtll Air Filled 1st Floor Zone 35 Window Left (W) 6.0 0.330 NFRC 0.25 NFRC 270 90 New NonMtll Air Filled 1st Floor Zone 36 Window Left (W) 48.0 0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled 1st Floor Zone 37 Window Left (W), 20.6 _0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled _ 1st Floor Zone 38 Window Left JWL 31.8 0.330 NFRC 0_25 NFRC 27090 New NonMtll Air Filled 1st Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # _Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hg'_ Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen _ 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen _ _0.76 26 Bug Screen _ 0.76 27 Bug Screen 0.76 28 Bug Screen___ _ 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen _ 0.76 33 Bug Screen _ 0.76 34 _ Bug.Screen 0.76 35 Bug Screen 0.76 36 Bug Screen _ 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Tvoe Insulation Condition Locati)n/ R -Val. Location JA IV Reference Status Comments I EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 6040511 Paoe:5 of 14 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R mer Residence 11/6/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 3R -Window Left (W) 48.0 0.330 NFRC Q.25 -RHE C 270 _9R Ne.w -doaMM Air Filled _-1sLElooLZone 40 Window Left (W) 20.6 0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled 1st Floor Zone 41 Window Left (W) 25.0 0.330 NFRC 0.25 NFRC 270 90 New NonMtll Air Filled 1st Floor Zone 42 Window Left (W) 81.0 0.330 NFRC 0.25 NFRC 270 90 New NonMtll Air Filled 1st Floor Zone 43 Window Rear (N) 3.0 0.330 NFRC 0_25 NFRC 0 90 New NonMtll Air Filled 2nd Floor Zone 44 Window Rear (N) 3.8 0.330 NFRC 0.25 NFRC 0 90 New NonMtll Air Filled 2nd Floor Zone 45 Window Right E 3.8 _ 0.33 NFRC 0025 NFRC 90 90 New NonMtll Air Filled 2nd Floor Zone _ 46 Window Right E 40.0 0.330 NFRC 0.25 NFRC 90 90 New NonMtll Air Filled _ '2nd Floor Zone 47 Window Right (E) 8.0 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 2nd Floor Zone 4$ Window Right (E� 4.0 0.339 NFRC 0.25 NFRC 90�9 New NonMtll Air Filled _ 2nd Floor Zone 49 Window Right (E) 4.0 0.330 NFRC 0_25 NFRC 90 90 New NonMtll Air Filled 2nd Floor Zone 50 Window Front (S) 48.0 0.330 NFRC 0.25 NFRC 180 90 New NonMtll Air Filled 2nd Floor Zone 51 Window Front (S) 24.0 0.330 NFRC 0.25 NFRC _180 90 New NonMtll Air Filled _ 2nd Floor Zone 52 Window Front (S) 6.3 0.330 NFRC NFRC 180 90 New NonMtll Air Filled 2nd Floor Zone 53 Front (S) 40.0 _0.25 0.330 NFRC 0.25 NFRC 180 90 New NonMtll Air Filled _ 2nd Floor Zone 54 _Window Window Front (S) 3.8 NFRC 0.25 NFRC 180 90 New NonMtll Air Filled 2nd Floor Zone 55 Window Front (S)_ 3.8 _0.330 0.330 NFRC 0_25 NFRC 180 90 New NonMtll Air Filled 2nd Floor Zone 56 Window Left (W) 48.0 0.330 NFRC _0.2_5 NFRC 270 90 New NonMtll Air Filled 2nd Floor Zone 57 Window Left (W) 4.0 0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled 2nd Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin _# Exterior Shade T SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. HT. Dist. Len. Hgt. 39 Bug Screen _ 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen _ 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 B�uc Screen 0.76 53 Bug Screen_ 0.76 54 Bug Screen _ 0.76 55 Bug Screen 0.76 56 Bug Screen_ 0.76 57 Bug Screen _ 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type _ Length R -Val. Location JA IV Reference Condition LocatiDn/ Status Comments EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 6Q4051 Paae:6 of 14 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Taper Residence 11/6/2006 Project Title Date FENESTRATION SURFACES INTERIOR AND EXTERIOR SHADING Window # Exterior Shade Type SHGC Hgt. Wd. Overhang Len. Hgt. LExt. RExt. True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments -5a–W..indow—Left (yam_3.D 0.330 NERC 0.25 -NFRC 270 —91L New NonMtll Air Filled _2n Floor Zone 59 Window Left (W) 3.0 0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled 2nd Floor Zone 60 _Window Left (W) 9.0 0.330 NFRC 0.25 NFRC 270 90 New NonMtll Air Filled 2nd Floor Zone 61 Window Left (W) 3.8 0.330 NFRC 0_25 NFRC 270 90 New NonMtll Air Filled 2nd Floor Zone Area Thick. Heat Inside Condition Location/ 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window # Exterior Shade Type SHGC Hgt. Wd. Overhang Len. Hgt. LExt. RExt. Left Fin Right Fin Dist. Len. Hg,- Dist. Len. Hgt. 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 6Q4051 Page:7 of 14 1 Certificate Of Compliance: Residential (Part 22 of 4) CF -1 R Taper Residence Duct Condit on Ducts _ R -Value Status 11/6/2006 _ Project Title 4.2 New No HVAC Ducted Ducted Attic Date Yes HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Sta-1_us Type Heat Pump Packaged Heat Pump 7.20 HSPF Packaged Heat Pump 13.0 SEER New Setback HVAC Central Furnace 90% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condit on Ducts Location _Heating Cooling Location R -Value Status Tested? Heat Pump Ducted Ducted Attic 4.2 New No HVAC Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard 100 gal Gas System Large Gas All Pipes Ins 1 199,999 100 New 0.T3 2.21% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ML Add 1/2' Control # HP Type In Plenum Outside Buried Insulation REMARKS Attached Heating & Cooling load summary as well as the WS -5R are submitted as part of the calculations required by the cuwent regulations. DO NOT US E FOR ACTUAL HEATING & AC or LIGHTING DESIGN Imo_ COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the CE lifornia Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulaton installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Wayne Seward, CEA R05-04-518- Title/Firm: Andrzej W. Weber Architect AIA Title/Firm: Bear Technologys Address: 74 133 EI Paseo Suite A Address: 7774 Calle Melor Palm esert A 92260 Carlsbad, CA 92009 Telephone: 760 40-30 Lic. #: Telephone: 760) 635-2327 � �G. � � 11/06/2006 (signature (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: _ STAMP P Telephone: (signature) - (date) nergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 6Q4051 Page:8 of 14 Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Taper Residence 11/6/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the rdequacy of the special justification and documentation submitted. Plan I Field IThe DHW Svstem "Standard 100 aal Gas Svstem" is a Larae Gas water heater with Pilot Loss = 0 btuh. I I I HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- .,.,.....�....�.. ,,..,..,.�. ,.�...y ..", arr..,.�...��....y a..,.,....�......a..,,.....�,...,,.� a,.,......�..,� .��.,..a,..,.....Q ... �.. I nstallation certificate. Plan The HVAC System "HVAC" incorporates HERS verified Duct Leakage. Target leakaqe is calculated and documented on theCF-4R. The HVAC System "HVAC" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansicn Valve. EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 6Q4051 Page:9 of 14 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - ENFORCE - permit application documentation. NIA DESIGNER MENT Building Envelope Measures .§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value:_ __ ❑ ❑ ❑ M§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). •§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. t ❑ ❑x ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ��II _I ❑ ❑ b: outside air intake with damper and control, flue damper and control ❑ ❑ 2. No continuous burning gas pilot lights allowed. ID ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include t—t I_I El E]CF-6R Form: _ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient ❑ ❑X ❑ (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ u ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ®R ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft _ _ User Number: 5956 Job Number: 6Q4051 Page: 10 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. ENFORCE - N/A DESIGNER MENT Space Conditioning, Water Pleating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604L ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ X❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ [I ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ 0 ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑X ❑ buming pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btulhr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table❑ X❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 6Q4051 Page: 11 of 14 Residential Kitchen Lighting Worksheet WS -SR Taper Residence 11/6/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts Quantity High Efficacy Watts Other Watts (1) 2 ft Fluorescent T8 Elec Yes X No 7 22.0 x _ 4 = 8B or (1) 26w Compact Fluorescent Quad 2 Pin Yes X1 No 1 37.0 x 3 = 1-1 or (1126w Compact Fluorescent Triple 4 Pin Yes X No 28.0 x 14 = 392 or Surface Mount Incandescent Yes No X 60.0_ x 4 = or 240 Yes No x = or Yes No x = or _ Yes No x = or Yes No x = or _ Yes I No x = or _— Yes No _ x = or _ Yes No x = __ or _ Yes No _ x = or Yes No x = or _ Yes No _ x = or _ Yes No x = _ or Yes No I I_ x _ = or _ Yes x = — or Yestv x = or _ Yes x = or Yes x = or Total A: 541 B: 240 COMPLIES IF A _> B YES ® No ❑ L_ EnergyPro 4.3 by EnergySoft User Number: 5956 _ Job Number: 6Q4051 Page: 12 of 14 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE _ Taper Residence 11/6/2006 SYSTEM NAME FLOOR AREA Heat Pump 937 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sqft) 0.0 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 51.2 Total Output (sgft/Ton) 234,2 Air System CFM per System 855 Airflow (cfm) 855 Airflow (cfm/sgft) 0.91 Airflow (cfm/Ton) 213.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 ote: values above given at ARI conditions ;ATING SYSTEM PSYCHROMETRICS 26.0 of 68.4 of Outside Air 0 cfm 68.4 of 111.0 / 72.5 of 1 Outside 0 cfm 80.5/56.3 of EnergyPro 4.3 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 369 14,147 4 348 14,222 0 2,318 1,466 0 0 0 0 0 0 0 0 0 2,318 1,466 18,783 4 17,154 Heat Pump 37,443 0 0 Total Adjusted System Output 37,aa3 01 L� (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2Qm Jan 12 am earn Temoeratures at Time of Heating Peak) 110.0 of Heating Coil 110.0 OF `""``'P Supply. Air Ducts Supply Fan 108.4 of 855 cfm ROOMS 70.0 of Return Air Ducts I 80.5 / 56.3 of 39.4 / 37.4 of 39.4 / 37.4 of y Supply, Air Ducts Cooling Coil Supply Fan 41.9 / 38.8 of 855 cfm 20.9% R.H. ROOMS 78.0155.4 of Return Air Ducts User Number: 5956 Job Number: 604051 PanA.11 of 1, 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Taper Residence 11/6/2006 SYSTEM NAME FLOOR AREA HVAC 4,619 ENGINEERING CHECKS SYSTEM LOAD Number of Systems a Heating System Output per System 90,000 Total Output (Btuh) 360,000 Output (Btuh/sqft) 77.9 Cooling System Output per System 37,800 Total Output (Btuh) 151,200 Total Output (Tons) 12.6 Total Output (Btuh/sgft) 32.7 Total Output (sqf rron) 366.6 Air System CFM per System 2,000 Airflow (cfm) 8,000 Airflow (cfm/sqft) 1.73 Airflow (cfm/Ton) 634.9 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 LNat., values above given at ARI conditions _ I Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD ICOIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latest CFM I Sensible 2,607 63,801 -1926 LIn 67,361 0 Supply Air Ducts 5,412 4,115 0 0 0 0 0 0 0 Supply Fan Heating Coil 8000 cfm 0 ROOMS 0 5,412 4,115 74,625 1,926 75,592 is Furnace 113,887 15;537 360,000 Total Adjusted System Output113,887 1E.,537 360,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 69.5°F 69.5°F 105.0°F Supply Air Ducts Outside Air 0 cfm 104.5 °F Supply Fan Heating Coil 8000 cfm ROOMS 70.0 OF 69.5 OF Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 72.5 OF 78.6 / 62.3 OF 78.6 ! 62.4 OF 55.0 / 53.7 OF Supply Air Ducts Outside Air 4t. . 0 cfm Supply Fan Cooling Coil 55.6 / 53.9 OF 8000 cfm ROOMS 40.8vo R.H. 78.6/62.3 °F 78.0 ! 62.1 OF Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 5956 Job Number: 6Q4051 Paae:14 of 1-4-