Loading...
07-1962 (SFD).­ I ''N c&ht 4 ' P.O. BOX 1504 78-495 CALLE TAM-PICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 07-00001962 Owner: Property Address: 80880 VIA PORTOFINO RUSTON HAFIF APN: 772-480-031- - - 4742 LIVE OAK CANYON ROAD Application description: DWELLING - SINGLE FAMILY DETACHED LA VERNE, CA 91750 '�- Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 426751 JU Applic t: Architect or Engineer: Lic. No.: OOR SQUARE FOOT ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 fcommencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 595212 Date-% 'ti Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply. to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property whobuilds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/05/08 u Contractor: MAR RH DEVELOPMENT " 05 20og 4742 LIVE OAK CANYON R AD 1!U LA VERNE, CA 91750 C1 F (909) 593-7378FINgNCE Q�1 . Lic. No.: 595212 ` SEPT. ----------------------------------------------- WORKER'S COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date.:S��Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessationof work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date: 1 7'0 Signature (Applicant or Agent): f Permit . . PLUMBING Additional desc . . LQPEINiIT Application Number . . . . . 07-00001962 Permit . . . . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 1784.00 Plan Check Fee 1159.60 Issue Date . . Valuation 426751 Expiration Date 8/18/08 Qty Unit Charge Per Extension - BASE FEE 639.50 327.00 3.5000 -----------------=----------------- THOU BLDG -------------------------- 100,001-500,000 --------------- 1144.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 15.00 Plan Check Fee 3:75 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/18/08 Qty Unit Charge Per Extension ----------------------- ------------------------------------------- BASE FEE 15.00 . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 8/18/08 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . . Permit Fee 150.50 Plan Check Fee 37.63 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/18/08 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 9.0000 EA MECH FURNACE <=100K 45.00 5.00 9.0000 EA MECH B/C <=3HP/100K BTU 45.00 .6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 ---------------------------------------------------------------------------- EA . MECH EXHAUST HOOD 6.50 Permit . . PLUMBING Additional desc . . LQPEINiIT 1�1:_.- li Application Number . . . . . 07-00001962 Permit . . . . PLUMBING Permit Fee 260.25 Plan Check Fee 65.06 Issue Date Valuation . . . 0 Expiration Date 8/18/08 Qty Unit Charge Per Extension BASE FEE 15.00 28.00 6.0000 EA PLB FIXTURE 168.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 3.00 7.5000 EA PLB WATER HEATER/VENT 22.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 17.00 .7500 EA PLB GAS PIPE >=5 12.75 1.00 15.0.000 EA PLB GAS METER 15.00 ----------------------------------------------- ---------------------------- Special.Notes and Comments 4816 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK OR DRIVEWAY APPROACH.October 25, 2007 2:04:39 PM JJOHNSON ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 566.87 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 115.96 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 42.67 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged --------------------------- Paid Credited ---------- Due Permit Fee Total -------------------- 2224.75 .00 .00 2224.75 Plan Check Total 1266.04 750.00 .00 516.04 Other Fee Total 5215.50 .00 .00 5215.50 Grand Total 8706.29 750.00 .00 7956.29 LQPERMiT o', - tot LcT T -a Z ar C-H(Dr=AWAY P.O. BOX 1504 APPLICATION ONLY Building pT� 78-495 CALLE TAMPICO Addre 80060 .> I OIZN tiJ OUINTA, CALIFORNIA 92253 Own g Z vOV ,�� A3 't- b' BUILDING: TYPE CONST. RE OCC. GRP. Mailing J Address L.I,� Z �,� ✓E OAIC Cy-► -PID A.P. Number rf' "4"�' " �"17Z 1 "OiP -031'0 City Zip Contractor Project Description �i N� t� r�>'4M i R Eslrl� EN GG S d r `� S i n�G I E STaCZ-i/ L4 . 9 1 6 5 Cf -F r Haaress 4-7gz I�I✓6 0144 CVV Y N �.-al ✓F2 rvE �liSc� qoq 5q 3-73 & Classif.(a G6/t% f KIc' # 5qs ' Z 1 Arch., Engr. '- DesignerA_F1 'CA1-, 5T0IJ7� AAAA , Address Tel. �5® wtr�t f�dMa �a vE qoq 5q3 _ q8 o I City Zi State L'i+4"Mo� 9p1—t l( Lic. #& I I Z( S LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or, im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company 0 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS'COMPENSATIONINSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employany person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit whenproperly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT _V0 ^n ti o n11 e Sp,aN►s ►-1 - Ml�sio./V sryIG' Sq. Ft.; 6 Fi No. Size �,� Sq . Stories ( No. Dw. Units New)K Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation 1�CIC) `o�O coM ETEo PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure FINAN E DEPT. TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by:— Validated by: 1 Validation: YELLOW = APPLICANT Date PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Owner's Name: Ruston Hafif Ruston Hafif This Box For District Use Only DEVELOPER FEES PAID AREA AMOUNT LEVELONEAMOUNr: LEVELTWO AMOUNT: MITIGATION AMOUNT: COMMnND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Address: 80-880 Via Portofino, La Quinta, CA Project Description: 1 Single Family Dwelling APN: 772-180-031-04 Tract #: Date: 2/08/08 Phone No. (909) 6184744 Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 4,816 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 2/08/08 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. Amount per Sq.Ft. Amount Collected 4,816 sq. ft. $ 3.48 $ 16,759.68 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/mvdocs/devfees/certificate of compliance form tables]'O USG.doc 1/16/03 T 4-16-281 4:59AM FROM s'.ItEco"IN�.;REOUESTED BY Lawyers Title Co WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: Ruston Hafif 4742 Live Oak Canyon La Verne, CA 91750 APN: 772-480--031-4 Escrow No: 07602395 -706 -PB Title No: 07602395-19 P. 2 DOC N 2®MS-0852244 10/19/2005 08:00A Fea:10.00 Page 1 of 2 Dee T Tax Paid Recorded in Official Records County of Riverside Larry U. Ward Assessor, County Clerk & Recorder I Illlli !illi!! 111 Illllil IN !11111 Illl� iii illi! Ili! Ill! M S U PAGE SIZC OA 'CAR NOGOP. SKJ= tA= L OOPY NOVGTEXAM t�3 A R LONG REFUND Ow y W space a00Ve"tn1s TME Tor' Recorder•s'use GRANT (DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $742.50, CITY TAX $ 0.90 computed on full value or property conveyed, (`itvsc o•, a '.a'. FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Fred Segal, Trustee, Trustee of THE FRED SEGAL LIVING TRUST dated August 30, 1994 hereby GRANT(S) to Ruston Hafiif, an unmarried man the following described real property in the ftpog AkamW , County of Riverside, State of California: All that certain real property situated in the County of Riverside, State of California, described as follows: See Exhibit "A" attached hereto Commonly known as: Lot 125 Via Portofino, La Quinta, CA Dated: July 19, 2005. . Fred Segal Trustee of THE FRED SEGAL LIVING T UST dated Aug st 30, 1 94 Fred Segal, Truster �.. STATE OF CALIFORNIA COUNTY OF .J (s j,o _ ,��� S5. On before me, Notary Public, personally appeared T Z 7,-4 �-- _ personally known to me (or proved to me 0'n -tie basis of -satisfactory evidence) to be the person(s) whose name(s) is/a-e subscribed to the within instrument and acknowledged. to me that he/she/they executed the same in his/her/the;r auiho'izcd capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the Instrument. WITNESS my hand and official seal. 7 CARO. FRIEDMHS ). COMM. # 132B 146' NOTARY PU8LC_CAUFORAtW Q Signature VnMgTA BARBARA COUNTY 0 COMM. EXP_ NOV. 2. 2MS,' FOR NOTARY SEAL OR STAMP MAIL TAX STATEMENTS AS DIRECTED ABOVE 4-18-201 11.40PM FROM P_2 r �a Exhibit A All that certain real property situated in the County of Riverside, State of California, described as follows: ParCel 1: Lot 125 of amended Tract No. 29894-2, in the.City of La Quinta, County of Riverside, State of California., as per Map recorded in Book 327, Pages 56 through 88 inclusive of Maps, in the Office of the County Recorder of said County. Excepting therefrom to grantor, and its successors and assigns, interest in all water, minerals, oil, gas, petroleum, other hydrocarbon substances and all geothermal energy sources in or under said land or which may be produced from said land. Pa LggL-L Non-exclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. 0j- Certificate of Occupancy 04 OFTiBuildin & Safet Department 9► Y p This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-880 VIA PORTOFINO Use classification: SINGLE FAMILY DWELLING Building Permit No.: 07-1962 Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RL Owner of Building: RUSTON HAFIF Address: 4742 LIVE OAK CANYON ROAD City, ST, ZIP: LA VERNE, CA 91750 �.� By: STEVE TRAXEL Date: MARCH 04, 2009 Building Official POST IN A CONSPICUOUS PLACE i ,,I TITLE 24 REPORT I Title 24 Report fo Hafif Residence Main H Lot #125 Via Portofir La Quinta, CA 9224 Project Designer: Patrick L. Stout 3850 Williams Ave. Claremont, CA 91711 909-593-4801 CITY OF LA QUINTA BUILDING & SAFETY DEPT. s' APPROVED FOR CONSTRUCTION DATE 11113A2 BY Report Prepared By: Ted Manuel Manuel's Design 679 E. Marshall Ct. Claremont, CA 91711 (909) 621-6760 Job Number: 100107 Date: 12/4/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building E This program developed by EnergySoft, LLC - www.energysoft.com. ram has approval and is iciencv Standards. EnergyPro 4.4 by EnergySoft Job Number. 100107 User Number. 5374 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary 1 2 3 7 9 10 EnergyPro 4.4 by EnergySoft Job Number. 100107 User Number. 5374 ' Certificate Of Compliance: Residential 50 Single Family (Part 1 of 4) CF -1 R H,gfifResidence Main Project Title House ❑ Mufti Family 12/4/2007 Date I of #12.5 Via Portofino Project Address Lq Quenta Building Front Orientation: (S)180 deg Building Permit # Manuel's f)Pcinn Fuel Type: (909) 621-6760 Slab on Grade Area: Documentation Auth r Fenestration: Telephone Plan Check/Date EnaravPro Complifi ce Method Area: CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance Number of Stories: (kBtu/sf-yr) Design Design Margin # of Thermostat Space Heating 1.39 2.66 -1.28 Units Zone Type Type mon Cnnditinned Setback Space Cooling 59.57 54.59 4.98 Fans 8.45 7.74 0.71 Domestic Hot Water 5.86 6.48 -0.63 Pumps 0.00 0.00 0.00 Totals 75.26 71.48 3.79 Percent better than Standard: 5.0% Building Type: 50 Single Family ❑ Addition Total Conditioned Floor Area: 4,384 ft2 ❑ Mufti Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (S)180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 4,384 ft2 Fenestration: Average Ceiling Height: 9.0 ft Area: 937 ft2 Avg. U: 0.35 Number of Dwelling Units: 1.00 Ratio: 21.4% Avg. SHGC: 0.30 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Znnes # 1,2 34,5 Floor Area Volume a 3843 39 a +� Units Zone Type Type mon Cnnditinned Setback Hgt. Area 2 -n/ OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wend Ago n_o74 R-19 R-0.0 180 q0 Wall Wood 40 0.074 R_19 R-0-0 135 9.Q Wall Wood 44 _0,074 R_19 -0.0 _995_ go Wall Wond 358 n 074 R_19 R-0 0 270 g0 Wall Wood 538 _0_074 -R-19 R-0 0_ Q_ go Wall Wood 23 0.074 R_19 R -0.0_-31`z 90 Wall Wood 9 0 074 R_19 R-0 fl 45 Wall Wood 653 0.074 R-19 R-0.0 _90 A Roof Woad__ 4,384 _0_025 -38 R-0.0 _0 0 Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.4 by EnergySoft User Number. 5374 Job Number. 100107 Page:3 of 10 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Hafif Residence Main House 12/4/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCz Azm. Tilt Stat. Glazing Type Comments 2 Window Window Front Right (S)_ (SE) X45.0_ 035 NF$CQ30 NFRC 180 —9n New Marvin Clad Casernaster Low E 10.0 0.350 NFRC 0_30 NFRC 135 90 New Marvin Clad Casemaster Low E 1st Floor Main House 1st Floor Main House 3 Window Front (SW) 28.0 0.350 NFRC 0_30 NFRC 225 90 New Marvin Clad Casemaster Low E 1st Floor Main House 4 Window Left (W) 110.0 0.350 NFRC 0_30 NFRC 270 90 New Marvin Clad Casemaster Low E 1st Floor Main House 5 Window Rear (N) 264.0 0.350 NFRC 0_30 NFRC 0 90 New Marvin Clad Casemaster Low E 1st Floor Main House 6 Window Left (NW) 76.0 0.350 NFRC 0_30 NFRC 315 90 New Marvin Clad Casemaster Low E 1st Floor Main House 7 Window Rear (NE) 67.0 0.350 NFRC -0-30 NFRC 45_ 90 New Marvin Clad Casemaster Low E 1st Floor Main House 8 Window Right (E) 237.0 0.350 NFRC 0_30 NFRC 90 90 New Marvin Clad Casemaster Low E 1st Floor Main House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. Len. Hgt. Dist. Len. Hgt. 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Roll -down Blind or Slats 0.13 4 Roll -down Blind or Slats 0.13 5 Roll -down Blind or Slats 0.13 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 12/04/07 09:46:12 Run Code: 1196790372 EnergyPro 4.4 by EnewSoft User Number. 5374 Job Number. 100107 Page:4 of 10 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Hafif Residence Main House 12/4/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Zones # 1,2,3,4,5 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Zones# 1,2,3,4,5 Ducted Ducted Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Attic 4.2 New No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard 75 gal or less Large Gas All Pipes Ins 3 80,000 75 New 0.78 1.91% 4.3 Mufti -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Tvoe In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Tide 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) -cMc Name: F , � . (;Tw'r Tide/Firm: Patrick L. Stoutj�� Address: 3850 Williams Ave. Claremont CA 91711 Te7Z;9099��� Lic. #: t✓' /� A c (si ature) (date) Enforcement Agency Name: Tide/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Ted Manuel Title/Firm: Manuel's Design Address: 679 E. Marshall Ct. Claremont, CA 91711 Tele 909 621-6760 Y (s natu ) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Hafif Residence Main House 12/4/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the iustification, and may resect a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof Attic" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The DHW System "Standard 75 gal or less" is a Large Gas water heater with Pilot Loss = 0 btuh. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan FFleId I EnergYPro 4.4 by EnerpvSoft User Number. 5374 Job Number. 100107 Paae:6 of 10 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -IR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supenxde the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. WA DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ 1150(.): Minimum R-19 in wood ceiling insulation or equivalent U -fader in metal frame ceiling. ❑ 191 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ Q ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ perrneance rate no greater than 2.0 perm/inch. ❑ ❑X ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Extiiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ Q ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ Q ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ Q ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is endosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPno 4.4 by EnergySoft User Number. 5374 Job Number. 100107 Page:7 of 10 Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supenoede the items marked with an asterisk (") below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes when completed or check NIA If not ENFORCE. aoolicable_ NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supply -air and retumair ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be seated with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. ❑X 0 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑X ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between fitter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑X ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 l)cations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number. 5374 Job Number. 100107 Page:8 of 10 Residential Kitchen Lighting Worksheet WS -5R Hafif Residence Main House 12/4/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be In luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following Information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts Quantity High Efficacy Watts Other Watts (1) 13w Compact Fluorescent Twin 4 Pin Elec Yes X No 13.0 x 3 = 39 or 1 26w Compact Fluorescent Triple 4 Pin Yes X1 No 1 26.0 x 2 = 52 or NMw Compact Fluorescent Triple 4 Pin Yes X No 1 32.0 x 26 = 832 or nded Rail Lighting Yes No X 300.0 x 2 = or 600 Yes No x = or Yes No x = or Yes No x = or Yes I No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 923 B: 600 COMPLIES IF A;-)- B YES ® NO ❑ I EnergyPro 4.4 by Energysoft User Number. 5374 Job Number. 100107 Page:9 of 10 1 *HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hafif Residence Main House 12/4/2007 SYSTEM NAME FLOOR AREA Zones # 1,2,3,4,5 4,384 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 2,149 34,769 4,163 976 40,608 0 5,406 5,210 0 0 0 0 0 0 0 0 0 5,406 5,210 45,58 4,163 Maytag W,731 67,199 Total Adjusted System Output 1x6,731 x7,199 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 26.0 of 69.4 of 69.4 of n 109.7 of Outside Air 0 cfm Supply Fan Heating Coil 8400 cfm 69.4 of h Retum Air Ducts 'I 11.0/77.6OF 78.6/66.8OF 78.6/66.8OF ® 62.2/61.2OF Outside Air 0 cfrn 78.6/66.8 of Supply Fan Cooling Coil 8400 cfm 51,028 360,000 36Q Jan 12 am Supply Air Ducts 109.1 of ROOMS 70.0 of Supply Air Ducts 62.8 / 61.4 of 55.5% R.H. ROOMS 78.0 / 66.6 of Return Air Ducts EnergyPro 4.4 by EnergySoft User Number. 5374 Job Number. 100107 Page: 10 of 10 I TITLE 24 REPORT Title 24 Report for: Hafif Residence Casita Lot #125 Via Portofino La Quinta, CA 92247 Project Designer: Patrick L. Stout 3850 Williams Ave. Claremont, CA 91711 909-593-4801 Report Prepared By: Ted Manu 679 E. l_ Clare�� 62'Y-6,;7 jd SAPE Y //V 7,,q FpR CCN ®V� DFpT 04 TRUCT� uel Job Number: 100107 Date: 11/9/2007 � DEC 10 2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. I EnergyPro 4.4 by EnergySoft Job Number. 100107 User Number. 5374 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 Form WS -5R Residential Kitchen Lighting 9 HVAC System Heating and Cooling Loads Summary 10 EnergyPro 4.4 by EnergySoft Job Number. 100107 User Number. 5374 1 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R Nafif Residence Casita 1119/2007 Project Title Date lot #125 Via Portof no La_Owinta __— Project Address Building Permit; ManueN. n -an (909)__Q21 -67L60 Plan Check/Date Documentation Auth r Telephone Fntm-W vPro __— CA-GlimateZorne_1.5 Field Check/Date Complf Tice Method Climate Zone - TDV Standard Proposed Compliance _(Btu/sf-yA Design Design_ ___Ma_Min__ Space Heating 2.17 2.49 -0.32 Space Cooling 97.55 105.17 -7.62 Fans 14.02 14.94 -0.92 Domestic Hot Water 35.79 25.70 10.09 Pumps — _ 0.00 0.00 _ _ 0.00 Totals 149.53 148.31 1.23 Building Type: Y Single Family ❑ Addition Total Conditioned Floor Area: 432 ft2 ❑ Multi Family [] Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (S)180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 432 ft Fenestration: Average Ceiling Height: 9.0 ft Area: 142 ft2 Avg. U: 0.35 Number of Dwelling Units: 1.00 Ratio: 32.9% Avg. SHGC: 0.30 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area 7nnec # 1 — 432 —3,M __1.00_ ronditinned—._ Sethack— --2 _ n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Weed —1,42 . n X74 .R-19 _B=OA —]80 —90 Wall Wood 50 0.074 R_19 R-0.0 135 9 Wall Wood 126 _0.074 X19 R-0.. 970----90 Wall Wnnd 225 -DMZ4 R_19 R -0 _a ---d —q0 Wall Wond _243 0.074 R_19 _RAO 9090 Bont— Wood 432 0025 R_38 R -Q O_ --n _O Gains Condition Y / N Status JA IV Reference Location / Comments New _ 9-A5 1st Floor Casita New 09.951st Eloor Casita New 09-A5 _ 1stFloor Casita NamL- J19-95_. __— act Flnnr Casita New _ n9 -A5 _ 1st Floor Casita _ Ngy- 01-A18 1st Flor Casita I EnemvPro 4.4 by EnemvSoft User Number. 5374 Job Number. 100107 Page:3 of 10 1 Certificate Of Compliance : Residential _ (Part 2 of 4) CF -1 R Hafif Residence Casita _ _11/9/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' _ SHGC2 Azm. Tilt Stat. Glazing Type Comments -1— Window Front (S) 250 0.350 NFRC 030 _NFRC 180 ___SD_ New Marvin Clad Casemaster Low -F-- 1sLFloor Casi s 2 Window Left (W) 117.0 0.350 NFRC 0.30 NFRC _ 270 90 New Marvin Clad Casemaster Low E _ 1st Floor Casita 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Toe SHGC Hg;__ Wd. Len. Hcgt.LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference _ Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments EnergyPro 4.4 by EnergySoft User Number. 5374 Job Number. 100107 Page:4 of 10 Certificate Of Compliance : Residential (Part 3 of 4), CF -1 R Hafif Residence Casita _ _.__ __ 11/9/2007____ Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Zones # 1 Central Furnace 84% AFUE ._- Split Air Conditioner14.0 SEER New Setback — HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location _ R Value Status Tested? Zones # 1 Ducted Ducted Attic 4.2 New _ No Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution_ Syst. (Btu/hr) ((gal) _ Status or RE Loss (%) Ext. Standard 75 gal or less Large Gas _ All Pipes Ins _ 1 80,000 75 New 0.78 1.91% _ 4.3 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner l (per Business & Professions Code) Name: B�rMCIf—I L. Titte/Finn: Patrick L Stout AAC*h1'E4r — Address: 3850 Williams Ave. _ Documentation Author Name: Ted Manuel Title/Firm: Manuel's Design Address: 679 E. Marshall Ct. Claremont CA 91711 Claremont, CA 91711 Telephone: 2%593-4801 Lic. #: (i' 1 Id4 S Telephone: -(909) 621-6760 —� I►loo --- —:7(signatu (ate) (sighat re) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date] Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Hafif Residence Casita 11/9/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the iustification, and may resect a building or design that otherwise complies used on the adequacy of the special justification and documentation submitted. Plan Field The Roof "R-38 Roof Attic" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The DHW Svstem "Standard 75 gal or less" is a Large Gas water heater with Pilot Loss = 0 btuh. HERS Required Verification Items In this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. —70ia—n7 Field I EnernvPro 4.4 by EnemySoft User Number. 5374 Job Number. 100107 Page:6 of 10 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -IR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the penult documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or Initial applicable boxes or check NA if not applicable and Included with the ENFORCE - permit application documentation. _ WA DESIGNER MENT Building Envelope Measures *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ u ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ appy to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. F]El § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox 0 ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ U ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements speed in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 1500): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ perrneance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ LI t-1 I_I CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/ExriiVabon Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. El ff�� ox ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain 1 CJ tt�� ❑ Coefficient (SHGC), and infiltration certification. U 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ Eil ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ § 150(h): Heating and/or coding bads calculated in accordance with ASHRAE. SMACNA or ACCA. ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ t❑l l ^� ❑ § 150(j): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ 41 ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ 0 ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ CI ❑ Length of recirculating sections of hot water pipes shall be insulated to Table 150B. ❑ ❑ ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ------- ❑ u -- ------- EnergyPro 4.4 by EnergySoft User Number. 5374 Job Number. 100107 Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent oompilance requirements from the Certificate of Compliance supersede the items marked with an asterisk (") below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere In the documents or on this checklist only. DESCRIPTION Instructions: Check or Initial applicable boxes when completed or check NIA H not ENFORCE- anolicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Duds and Fans 1. All duds and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supplyair and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shag be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shag be used. (tel 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed �.� 1 n I ❑ sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Duds installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the duds. 1 3. Joints and seams of duct systems and their components shall not be sealed with doth back rubber adhesive El I. ❑ dud tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shag be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible duds cannot have porous inner cores. ❑ 1bl ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36" of pipe between fitter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ITKI ❑ burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (1): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ O ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. t § 150(k)2: Permanently installed luminaires in kitchens shag be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ I n 1 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ LJ ❑ OR are controlled by an occupant sensors) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, gerag b. l dhmmerooms, d are rooms ❑ ❑X ❑ shag be high efficacy luminaires (except closets less than 70 ft) OR arecon y by an occupant sensor that complies with Section 119(d) that daes not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shag be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking kits for 8 or more vehicles shag have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ r-1 r_1 ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro4.4 by EnergySoft User Number. 5374.--.----- v -- _ Job Number. 100107 Page:8 of 10 Residential Kitchen Lighting Worksheet WS -SR Hafif Residence Casita _ —_—! 11/9/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires In kitchens must be In luminaires that are high efficacy luminaires as defined In Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following Information for all luminaires to be installed In kitchens. High Efficacy Luminaire Type — High Efficacy? _Watts Quantity Watts _--_ Other Watts (1) 16w Compact Fluorescent Twin 4 Pin Elec Yes X No 13.0 x — 3 = _ 39 or (1 32w Corn ct Fluorescent Triple 4 Pin Yes X No 32.0 x 2 = 64_ or --- ----•- ETec6—- Yes No- x =or Yes No x —.-- _ --- or - - Yes No — --_— x -- - _ ---- -- or - _ Yes No - — -- -- x ------ _ ----- - or - - Yes No _ __---- x — _ —_ or Yes No - x --- -- --- -- --- --- . or -- -- Yes No_ -- x = — _ or Yes No __-- x --_-- _ _-. or — _ Yes No x = or - - Yes No_ x _ _- or Yes No _ __—_--__- x = or — Yes No x - -- _ --------- or Yes No — x = or Yes No — x _ _ or Yes No— x _-- _ --------...-.___ or -- -- _ Yes No x or — — _ --- Yes No x = ,-- or _ _ Yes No_ x -- _ _-• or ---- Total A: 103 B: 0 COMPLIES IF A Z B YES XI NO ❑ EnemyPro 4.4 by EnergYSoft User Number. 5374 Job Number. 100107 Page:9 of 10 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Hafif Residence Casita _ _ 11/9/2007 SYSTEM NAME FLOOR AREA Zones # 1 _ 432 Number of Systems Heating System _— Output per System Total Output (Btuh) Output (Btuh/sgft) 72,000 72,000 166.7 Cooling System 1,680 Output per System 3.89 46,500 Total Output (Stuh) Outside Air (%) — 46,500 Total Output (Tons) 0.o0 3.9 Total Output (Btuh/sgft) ` 1,13 107.6 Total Output (sgft/Ton) 111.5 Air 5vstem CFM per System 1,680 Airflow (cfm) 1,680 Airflow (cfm/sgft) 3.89 Airflow (cfm/Ton)— 433.5 Outside Air (%) — 0.0 Outside Air (cfm/sgft) 0.o0 Note: values above given at ARI conditions 26.0 OF 69.5 OF Outside Air 0 cfm Supply Fan 1680 cfm 69.5 of 111.0 / 77.6 of Outside �.� 0 cfm 78.7/66.9 of 4.4 69.5 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HT_G. PEAK _COIL CFM Sensible Latent CFM I Sensible L498 ` 1,13 l 157 — 6,580 --7,93 --- 0 1,233 0 844 0 ---- 0 --- o o 0 0 1,2331 0 844 -_._. 10 39@[1,113 8268 Maytag 29,222 13,688 72,000 Total Adjusted System Output 2s 222 13,su 72,000 (Adjusted for Peak Design Conditions)----__ TIME OF SYSTEM PEAK _Aug 2 pm Jan 12 am 109.8 OF Heating Coil �% Return Air Ducts y 78.7/66.9OF 78.7/67.0OF 62.3/61.4OF 0 Supply Fan Cooling Coil 1680 cfm User Number. 5374 of Return Air Ducts Job Number. 100107 Supply Air Ducts 109.3 of ROOMS 70.0 of Supply Air Ducts 63.0 / 61.6 of 56.0% R.H. ROOMS 78.0 / 66.7 of 10 of 10