08-1954 (SFD)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description:
Property Zoning:
Application valuation:
Applicant:
6*4 0G
08-00001954'
80815 VIA PORTOFINO
777-150-022- - -
DWELLING - SINGLE FAMILY
LOW DENSITY RESIDENTIAL
618834
T4-tyl 4 44ulk&
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
JAMES & ROBERTA WEYM
1445 EVERGREEN POINT
DETACHED MEDINA, WA 98039
Arcl itect or En ineer:
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class:
�- 'c seNo.: 769229
Date: b 'Contractor:
OWNER- UILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERNUT
Contractor:
ALBERS CONSTRUCTION
78060 CALLE ESTADO,.
LA QUINTA, CA 92253
(760)771-9954
Lic. No.: 769229
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/17/09
d �d
SUITE 1.` :` 'e f
WORKER'S COMPENSATION DECLARATION -
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the. work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0004885-2008
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become sub' c to the workers' compensation provisions of Section
3700 of Labor Code all f/y h it comply with those provisions.
Date: : 2 v4 Applicant: L p
WARNING: FAILURE TO SECURE WORKERS' C011FENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above 'nformation is correct. I agree to comply with all
city and county ordinances and state laws r�eellaatttiii to building co struction, and hereby authorize representatives
of this county to enter upon the abov -me)r "S prop2rty f r' spection purposes.
Date: Signature (Applicant ent).
Application Number . . . . . 08-00001954
------ Structure Information 7216 SF SFD
-----
Other struct info . .
. . . CODE EDITION 2007
# BEDROOMS
5.00
FIRE SPRINKLERS NO
GARAGE SQ FTG
1145.00
PATIO SQ FTG
1003.00
NUMBER OF UNITS
1.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
7216.00
Permit
. . . BUILDING PERMIT
Additional
desc . . 7216 SF SFD
Permit Fee
. . . .
2396.50 Plan Check Fee
1557.73
Issue Date
. . . .
Valuation . . . .
618834
Expiration
Date . .
8/16/09
Qty Unit Charge
Per
Extension
BASE FEE
2039.50
119.00
----------------------------------------------------------------------------
3.0000
THOU BLDG 500,001-1,000,000
357.00
Permit
. . ELEC-NEW RESIDENTIAL
Additional
desc .
Permit Fee
. . . .
325.52 Plan Check Fee
81.38
Issue Date
. . . .
Valuation . . . .
0
Expiration
Date . .
8/16/09
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
7216.00
.0350
ELEC NEW RES - 1 OR 2 FAMILY
252.56
2148.00
.0200
ELEC GARAGE OR NON-RESIDENTIAL
42.96
1.00
----------------------------------------------------------------------------
15.0000
EA ELEC TEMPORARY POWER POLE
15.00
Permit
. . .. MECHANICAL
Additional
desc . .
Permit Fee
. . . .
243.50 Plan Check Fee
60.88
Issue Date
. . . .
Valuation . . . .
0
Expiration
Date . .
1 8/16/09
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
2.00
9.0000
EA MECH FURNACE <=100K
18.00
3.00
11.0000
EA MECH FURNACE >100K
33.00
5.00
22.5000
EA MC B/C >15 <=30HP/500K-lM BTU
112.50
9.00
6.5000
EA MECH VENT FAN
58.50
1.00
6.5000
'EA MECH EXHAUST HOOD
6.50
LQPERMIT -
Application Number . . . 08-00001954
Permit . . .
PLUMBING
Additional desc . .
Permit Fee . . . .
225.00 Plan Check Fee
56.25
Issue Date . . . .
Valuation . .
0
Expiration Date . .
8/16/09
Qty Unit Charge
Per
Extension
BASE FEE
15.00
22.00 6.0000
EA PLB FIXTURE
132.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
3.00 6.0000
EA PLB ROOF DRAIN
18.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
14.00 .7500
EA PLB GAS PIPE >=5
10.50
1.00 15.0000
----------------------------------------------------------------------------
EA PLB GAS METER
15.00
Permit . . .
GRADING PERMIT
Additional desc . .
Permit Fee . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date . .
8/16/09
Qty Unit Charge
Per
Extension
BASE FEE
15.00
--------------------------------------------------
Special Notes and Comments
7,216 SF SINGLE FAMILY DWELLING.1145 SF
GARAGE, 1003 SF COV.
PATIO. 2007 CODES.
2G06 D.I.F. **PERMIT
DOES NOT INCLUDE
BLOCK WALLS, FENCES,
SWIMMING POOLS,
SPA, WATER FEATURES and
-----------=----------------------------------------------------------------
BBQ'S**
Other Fees . . . . .
. . . . ART IN PUBLIC PLACES-RES
1047.08
DIF COMMUNITY CENTERS-RES
74.00
DIF CIVIC CENTER - RES
995.00
ENERGY REVIEW FEE
155.77
DIF FIRE PROTECTION-RES
140.00
DIF LIBRARIES - RES
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC - RES
892.00
STRONG MOTION (SMI) - RES
61.88
DIF STREET MAINT FAC-RES
67.00
DIF TRANSPORTATION - RES
1930.00
Fee summary Charged
Paid Credited Due
LQPERMIT
Application Number
-----------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
. . 08-00001954
3205.52
.00
.00
1756.24
1400.00
.00
5739.73
.00
.00
10701.49
1400.00
.00
3205.52
356.24
5739.73
9301.49
LQPERMIT
o��-a-'"'�� Certificate of Occupancy.
G OFTiBuilding & Safety Department
This Certificate is issued pursuant to the requirements of Appendix Chapter 1 Section 110 of the
2007 California Building Code, certifying that, at the time of issuance, this structure was in
compliance with the provisions of the Building Code and the various ordinances of the City
regulating building construction and/or use.
BUILDING ADDRESS: 80-815 VIA PORTOFINO
Use classification: SINGLE FAMILY DWELLING
Occupancy Group: R=3 Type of Construction: VN
Sprinklers Installed: NO Sprinklers Required: NO
Building Official
Building Permit No.: 08-1954
Land Use Zone: RL
Occupant Load: 36
Owner of Building: JAMES & ROBERTA WEYMOUTH
Address: 1445 EVERGREEN POINT RD
City, ST, ZIP: MEDINA, WA 98039
By: STEVE TRAXEL
Date: APRIL 13, 2010
RECORDING REQUESTED BY:
SOUTHLAND TITLE - INLAND EMPIRE (Title)
AND WHEN RECORDED MAIL THIS DOCUMENT AND
TAX STATEMENTS TO:
James L. Weymouth and Roberta S. Weymouth
1445 Evergreen Point Road
Medina, WA 98039
Order No.: 67623664
Escrow No.: P013509-CY
A.P.N.: 777-154422
M4 &2o
DOC # 2008-0096023
02/27/2008 08:00A Fee:10.00
Page 1 of 2 Coo T Tax Paid
Recorded in Official Records
County of Riverside
Larry W. Ward
Assessor, County Clerk d Recorder
1111111111111111111111111111111111111111111111111
S R U PAGE SIZE OA I MISC I LONG RPO I COPY
M A L 485 428 1 tbO2NCORJ SMF NCHG UAV I
T: UNI
GRANT DEED t O
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX IS $ 6024.1 D
[ X ] computed on full value of property conveyed, or
[ - ] computed on full value less value of liens or encumbrances remaining at time of sale.4
[ - ] unincorporated area [ X ] City of La Quinta
FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged,
Thomas R. Hudson and Donna L. Bucher -Hudson, Trustees of the Revocable Living Trust Agreement for
Thomas R. Hudson and Donna L. Bucher -Hudson dated 8/10/98
t
hereby GRANT(S) to James L. Weymouth and Roberta S. Weymouth, husband and wife as community property
the following de cribed real property in the County of Riverside, State of California
Lot 149 of Aalended Tract o. 9894-2, in the�&Ky ( 'f La Oulnta, CdupWof Riverside, S e of
California, per map recon d in Book 327 a s) 5&8B, inciusa of Maps, in the Ice of the
County Reo er of said Co nty. .�Rh: ht 1 t A
Dated: February 7, 2008
STATE 0- Al "
COUNTY OF 1�.N4L ) SS.
On f"Y I'i 2009 before me
- Ch/lA A ym.el-ra I F
a Notary Public, personally appeared
'nbMA6 r2_ .tease J.I
who proved to me on the basis of satisfaclory evidence to be
the person(s) whose names) is/are subscribed to the within
instrument and acknowledged to me that., he/she/lhey
executed the same In his/herltheir authorized capacily(ies)
and that by histher/lheir signature(s) on the instrument the
person(s), or the entity upon behalf of which The person(s),
acted, executed the Instrument.
I certify under PENALTY OF PERJURY under -the laws of
the State of California that the foregoing paragraph is true
and correct
WITNESS my hand and official seal.
Signature
Signature of Notary
Thomas R. Hudson and Donna L. Bucher -
Hudson, Trustees of the Revocable Living
Trust Agreement for Thomas R. Hudson
and Donna L. Bucher -Hudson dated 8/10198
By: Thomas R. Hudson, Trustee
2&0 :,ding -_amu �7
By: Donna L. Bucher -Hudson, Trustee
Mopey AIpfIC
Iiwo Of iNoggfqbri
111VAP0eM11Mod tom" Mq►10. Sol 1
meow
(This area for official notary seal) U y I O
MAIL TAX STATEMENTS AS DIRECTED ABOVE
Public Record
M
File No. 67623864
EXHIBIT "N'
All that certain real property situated in the County of Riverside, State of California, described
as follows:
Parcel 1:
Lot(s) 149 of Amended Tract No. 29694-2, In the City of La Quinta, County of Riverside, State
of California, as per Map recorded in Book 327 Page(s) 56 through 88 inclusive of Maps, In the
office of the County Recorder of said County.
Excepting therefrom to grantor, and its successors and assigns, Interest in all water, minerals,
oil, gas, petroleum, other hydrocarbon substances and all geothermal energy sources in or
under said land or which may be produced for said land.
Parcel 2:
Non-exclusive easements for access, ingress, egress, drainage, maintenance, repairs and for
other purposes, all as described in the Declaration.
January 9, 2009
Mr. and Mrs. Jim Weymouth
1445 Evergreen Plant Road-
Medina,
oadMedina, WA 98034
RE: Weymouth /Final Design Review
Lot 149 at 80815 Via Portofino"
Dear Mr. and Mrs. Weymouth,
The Hideaway Design Review Committee met to review your submittal of Final' Design
plans for your Lot 149. You are approved to begin construction provided the following
comments are addressed before the setback inspection. The plans will need to be
reviewed and approved before the setback inspection can be scheduled.
1. The palm tree on the east end of the pool is located in the view corridor.
2. Please specify that the wattage is 25 maximum for the SPJ-14-02 light fixtures.
3.. Are pool and. spa equipment. located_ behind- walls, or in und_(zrgrou_nd.. vaults. to.
contain noise, please specify.`��
4. The building is over massed as the 20' allowable height is shown from the
finished floor. It needs to be shown from the finished pad. If lowered, it would
conform to. the guidelines. — hl-(� Alze Fy- y F'N, ?14p.
5. Please clarify on your next set of plans that the proposed walls are of a thickness
to allow windows to be recessed at least 6" on street or golf facades and 2" on
side facades and on the second floor elements. The details showing the minimum
required recess 6" and 2 minimum onopenings are not drawn and are not keyed
to the plan or elevations. '�, A) -4— ---, G/V 4S
6. Are the proposed doors, door frames and window frames wood clad or metal non -
anodized finish? The schedules are not specific, please clarify. G,CV—t&1,-jCU)j-ev
T Please note on the plans that the vents and flues will be minimized. cel A,!9 -
/,j v re -
,!9 -More- o/ov +/,
Any deviation from the Design Guidelines must be submitted with a request for Variance.
If a design element is not presented as a Variance request and the committee
inadvertently overlooks it during the review process it will be the design team's
responsibility to make modifications at a later date if requested by the Design Review
Committee. Please contact Mindy Gutierrez at (760) 393-5211 to schedule your
preconstruction meeting. We look forward to working, with you on the construction of
your new home.
Sincerely,
Hideaway Design Review Committee
cc: DRC File, AA Group, Ray Martin, Bill Albers
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated& effective 6/26/2008.
Green Sheet approvals are forwarded to the Buildinq & Safety Deoartment directly by Public. Works. Please DO
NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL
requirements listed below are complete. Incomplete applications or applications which cannot be processed will be
returned to applicant..
3%m 0)P_`lmOv-tVr-
D.ate:_I-Vo-VC� Developer:- -CoN14AVrtq,
Tract No-19&L1E2Jract Name: Lot No.(s): tyq
Address(s :: _$o $i5 Via �a-w�,..►o Phone Number: -tba 1-1y- $1$"1 CO
Lk Qu 4ra-rAr t<,0*_
The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the
Building & Safety Department:
�• CUSTOM HOMES: PROVIDE ITEMS .#2, #3, #4 AND #5 BELOW
❖ TRACT HOMES: PROVIDE ITEMS W#2. #3, #4 (AS APPLICABLE) AND #6 BELOW
•% COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1. #2. #3 AND #5 BELOW
❖ WALLS: PROVIDE ITEMS #7 BELOW
�• SIGNS: PROVIDE ITEMS#8 BELOW
OTHER: PROVIDE ITEM #9 BELOW
1. Attach Pad Elevation Certificates in compliance with. the approved design elevation for building pad
(maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6
months of current date). If a.precise grading plan creates the pad for approval, please withhold green sheet
submittal until a Pad Elevation Certificate can be provided.
(a._Attach geotechnical certification of grading plan compliance including compaction reports from a licensed
Soils Engineer. Recently rough graded residential developments which have a previously approved
eotechnical certification are exempt from this
re .QN IS
�Final
ttach recorded final map or title informatio geeowing proposed building locations are legal lots.
maps may be viewed at the following website:
htto://www.la-auinta.org/PlanCheck/m search.asrx
Attach a completed < 1 acre per lot or infill project Fugitive Dust Control project information form, PM10
plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy
plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with
grading plans & are subject to additional requirements. A current PM10 certification number is required.
Attach a copy of the precise grading plan to the Public Works Department showing building location(s). AO
flood zone developments will require an approved flood plain development plan.
6. Attach an approved rough or precise grading plan for the building location(s) for pad elevation verification or
City plan set number if available. Plans may be viewed at the following website:
http://www.la-auinta.org/PlanCheck/m search.aspx
7. Attach wall plan &related approved grading plan.
8. Attach sign layout/plan & related precise grading/landscape plan.
i 9. Attach supporting documentation for grease trap or special facility installations.
have reviewed and confirmed the requirements listed above as presented and find the improvements to be
sufficiently complete for construction of proposed buildings/structures/walls/signs on the subject lot(s).
Pursuant to my "aboveec ma be released for building permit issuance.
Recommended by: Dated: C7
Public Works Distribution: L,-4"Green Sheet to Building & Safety .
(_) Green Sheet to Planning Department
Declined for approval for reason(s) as follow(s), please correct and resubmit:
Page 1 of 4
Project Information ..
Project Contractor;
-Project Phase
(check,one)
Project Name":VJ Ly r+ auT y R=es Ili EN ee
Construction,
0 Demolition
Project Tract, Number. Z 9'8q y '-^
Lot Numbers y
Anticipated Start, Date:
Project Street Address: 4,9'0 .815 • V1Ar P6(L-mF1 t4 o
Anticipated Completion
a
y
Date: 2. -15 -%
t
Total Acres in Active
Construction (< 1 acre
per Lot): . So
AAe !•- Y'i `c " G (f
Please "note: 'Dust control is required
Project Contact
Information
regardless of construction status: Pers
.control duringbusiness.and non-busine`*
,►.� AL.gERS r
1� p:es la Irl T r
BeF.S Caesra-c.z;.a
o �0 2 3 8 `�• ' .�
OIN
''( Imo _ '1-11 - ctck 5 4`, s L
"1(00 • - .7 n - 9 8 3 I
Name:
Titles
Company Name:
Mailing Address:
e City:
State:':
Zip Code:
Primary Phone #:
Fax #:
24 Hour
t i
Access/Emergency
�. '
bo `- '1ZK- 87 81
Phone_#.
•
-74
Cell Phone #:
Email address:
b. 0ilbw,rs_ ec �-1kl�nk�n�-• "
PM10 Certificate #:
10 20
Fugitive Dust Control PM 10 Plan (< 1 acre per Lot or Infill Project)
Plan Updated 6-26-08
This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1,
401, 402, 201, 203 and Portable Equipment Registration Program (PERP).
❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four
(4) times daily. Water shall be applied from an adequate sized metered water source to dry soils
to prevent:
■ . Visible dust emissions .>20% opacity.
■ Visible dust emissions that travel > 100 feet from the.source (within site)
■ Visible dust emissions that cross any property line
EDUCATION: The responsible dust control Individual and -key personnel shall attend SCAQMD
PM10 class and obtain PM10 certificate number prior to construction activity (training information
may -be obtained by contacting SCAQMD at (909) 396-2183).
❖ CONSTRUCTION & DEMOLITION ACTIVITIES: A copy' of this approved Fugitive Dust Control
Plan must be kept on site. I At least one short-term stabilization method must be used during off
hours. At least one long-term stabilization measure must be used within ten (10) days of ceasing
activity.
WEATHER MONITORING: .Wind. predictions shall be monitored.
11- SIGNAGE: Approved signs shall be installed at. a highly visible location. Please refer to the
Coachella Valley Fugitive Dust Control Plan. Handbook for Construction Signage Guidelines.
•:� TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If
vehicles operate on pad, pad shall be kept firm and moist through hose watering and sprinklers;
and a maximum traffic speed of 15mph :will be enforced. Fugitive Dust shall be prevented by
fencing off site to prevent unauthorized traffic on pad. _
•'r PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas
only.
❖ TRACK OUT: Provide 24, hour street cleaning and track out system as approved by City Public
Works inspectors. No dirt on public or private. roads. Track out shall be cleaned up within one (1)
hour of incident and at the conclusion of each Workday.
DIRT PILES: Dirt piles shall be limited to 50 cubic yards .and built per California Building Code
grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will
require stockpile or grading permit.
FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat
fencing can be installed at rear of 'property and return 20 feet on either side if HOA restrictions
apply. Block walls can replace PM10 fencing during the construction phase.
EQUIPMENT: Extra hoses and sprinklers shall be maintained. on site.. ,
EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall.
also be applied during excavation or grading operations.
Page 3 of 4
Fugitive Dust Control PM 10 Plan (< 1 acre per Lot or Infill ' Project)
Plan, Updated 6726-08
•#
DUMP TRUCKS: Open top dump trucks shall be wet down, moist .and covered with a tarp
prior to leaving site.
❖
INACTIVE .SITE: Within 10 days of ceasing of activities, re-vegetate or :permanently stabilize
as required..
v
RECORD KEEPING: Fugitive Dust Control. Plan records (i.e. self. inspection records, records of
use of chemical suppressants, etc.) shall be maintained. for 3 .Years by the Property. Owner (or
Authorized Representative). Property Owner shall notify the City and .SCAQMD within 10 days of
completion of project.
City of La Quinta — Site Specific Construction Phase PM10 Agreement
Agreement Updated 6-26-08
The signature
of the property owner (or authorized representative):
❖
Shall 'act as his/her acknowledgement of dust control requirements and- their enforceability,
pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP;
6
Shall constitute an Agreement to comply with all project conditions as identified in the approved
dust control plan.
The property owner (or authorized representative):
-
Acknowledges that dust control is required twenty-four 124) hoursa day; .seven (7) days a week,
I
throughout the-period of project performance, regardless of project size "or status;
I ❖
Shall ensure that each and every contractor, subcontractor and all other persons associated with
the project shall be in continuous compliance with all requirements of. the approved dust control
"
plan; :.
:•.
Shall take all necessary precautions to minimize dust, even if additional measures beyond those
listed in the dust control plan are necessary;
�.�
Shall authorize representatives of City/County to enter, upon the property for inspection and/or
abatement purposes; and
-
Shall hold harmless the-City/County and its re' resentatives irom liability for any actions related to
this dust control plan.or any City/County initiated abatement activities.
T1�9
Signature
of Property Owner or Authorized Representative Date
AL8ere.s .
Printed Name of Property Owner or Authorized Representative: -Title of Property Owner or Representative
Company Name Phone Number e
y =877
Page 3 of 4.
inV
N46
I
January 23, 2009
P]
File No.: 11415-01
Doc. No.: 09-01-793
This report is issued with the understanding that the owner, or the owner's representative, has the
responsibility to bring the information and recommendations contained herein to the attention of
the architect and engineers for the project so that they are incorporated into the plans and
specifications for the project. The owner, or the owner's representative, also has the
responsibility to take the necessary steps to see that the general contractor and all subcontractors
follow such recommendations. It is further understood that the owner or the owner's
representative is responsible for submittal of this report to the appropriate governing agencies.
Earth Systems Southwest [ESSW] has striven to provide our services in accordance with
generally accepted geotechnical engineering practices in this locality at this time. No warranty
or guarantee is express or implied. This report was prepared for the exclusive use of the Client
,and the Client' s,.,authorized-agents. T_.t_-
This report is based on the assumption that an adequate program of client consultation,
construction monitoring, and testing will be performed during the final design and construction
phases to check compliance with these recommendations. Maintaining ESSW as the
geotechnical consultant from beginning to end of the project will provide continuity of services.
The geotechnical engineering firm providing tests and observations shall assume the
responsibility of Geotechnical Engineer of Record.
Should you have any questions concerning our report please give us a call and we will be pleased
to assist you.
Sincerely,
EARTH SYST ST
G S- <0
iv Ool•yC•o9�`
�/
CE 38234 z
Craig S. Hill
d Exp. 03/31/09 Z
CE 38234s�
civ►
gOF CAl\
LTR/csh/ajm
Distribution:
3/City of La Quinta
Building & Safety Department
1/Mr. Jim Weymouth
1/Albers Construction Co., Inc.
1/RF Structural Consultants, Inc.
2/BD File
EARTH SYSTEMS SOUTHWEST
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: James &-Roberta Weymouth ideaway)
Owner's Name: James & Roberta Weymouth
Project Address: 80-815 Via Portofino, La Quinta, CA
Project Description:
APN: 777-150-022
Type of Development:
New Single Family Dwelling
Date: 02/18/09
Phone No. (949) 361-0437
Tract #: 9,e — e Lot #'s: 109
Residential XX Commercial Industrial
Total Square Feet of Building Area: 7216 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: 02/18/09
Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 • Requirement
Number of Sq.Ft. 7,216 Sq. Ft._
Amount per Sq.Ft. $ 3.78
Amount Collected $ 27,276.48
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., SupportServices
Certificate issued by: Leticia C. Torres, Facilities Analyst Signature:
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that t is District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance less 3% for Administrative Fees to process the
reimbursement.
LT:c/mydoes/devfees/certificate ofcompliance,form tablesTO USE.doc 1 9/11/08
02/17/2009 16:42 7607777011 LA QUINTA BLDG DEPT PAGE 01101
' Building 8! Safety Department
78-495 Calle Tampico
o� PO Box 1504
La Quinta, CA 92253
(760) 777-7012 voice (760) 777-7011 fax
,
CERTIFICATION OF BUILDING AREA'
STREET ADDRESS OF JOB, 80-815 Via PORTOFINO
APN: 777-150-022
DESCRIPTION OF WORK: New Single Family Dwelling
SQUARE FOOTAGE: 17216 con ft:
2� 2� (o
OWNER'S NAME: JAMES & ROBERTA WEYMOUTH .
1445 EVERGREEN POINT ROAD
MEDINA, WA 98039
CITY OF LA
__ _��� BUILDING & S �(11N�-a
(Coachella Valley Unified School $'Tact • ? p AF�j�.OEP
83-733 Avenue 55 ~- Ap Fj0v1Z� T.
P 0 Box 847
Thermal, CA 92274 pArE Z
(760) 398 5909 !7 BY .
Desert Sands Unified School DistrictV
47-950 Dune Palms Road
Le Quinta, CA 92253
(760) 771-8595
Please Note: This Letter Verifies Conditioned Square Footage.
Please call your School District to Verify School Fees,
Requirement for Cashiers Check or Money Order and Hours of
Operation.
For questions regarding this letter, please call. -
Philip Juarez, Counter Technician (760) 777-7092
-l"
TITLE 24 REPORT
Title 24 Report for:
MR. & MRS. JAMES WEYMOUTH
80815 VIA PORTOFINO
LA QUINTA, CA 92253
Project Designer:
A + A GROUP ARCHITECTS
20341 SW BIRCH ST. # 320
NEWPORT BEACH, CA 92660
949-250-1909
Report Prepared By:
OMID TOHIDIAN
BUILDING MECHANICAL SYSTEMS, INC.
410 GODDARD
IRVINE, CA 92618
(949) 453-1999 CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTI N
DATE BY* $
Joh Numhpr-
1 /28/2009
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC- www.energysoft.com.
EnergyPro 4.4 by EnergySoft Job Number: User Number: 2936
it
• STT rc,�
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 12
Form WS -5R Residential Kitchen Lighting 14
HVAC System Heating and Cooling Loads Summary 15
Room Load Summary 20
EnergyPro 4.4 by EnergySoft Job Number: User Number: 2936
Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R
MR-' MRS .IAN].ESMEYMOHIH
-- . _ ...
_ -1/2$/2009
Project Title
Date
80815 VIA PORTOFIND I A CJl11NTA
Project Address
Building Permit #
_BU11 DING MECHANIC'Al SYSTEMS,1
(949) 453-1999
Documentation Author
Telephone
Plan Check/Date
rqyPm
CSA
(Timate 7pne 15
I Field Check/Date
Complia Method
Climate Zone
TDV Standard
Proposed
Compliance
ykBtu/sf-yr) Design
Design
Margin
Space Heating 2.24
2.11
0.13
Space Cooling 63.62
61.12
2.50
Fans 9.04
10.79
-1.74
Domestic Hot Water 3.56
3.56
0.00
Pumps 0.00
0.05
-0.05
Totals 78.45
77.62
0.84
Percent better than Standard:
I BUILDING COMPLIES - HER
Building Type: W Single Family ❑ Addition
❑ Multi Family ❑ Existing + Add/Alt
Building Front Orientation: (N) 0 deg
Fuel Type: Natural Gas
Fenestration:
Area: 1,740 ft2 Avg. U: 0.47
Ratio: 24.1% Avg. SHGC: 0.40
BUILDING ZONE INFORMATION
Zone Name Floor Area Volume
rASITAS/BFn/CnR 1470 X911
-GREAT RM / DININR/FOYE 1,99 16.7
BB DQE 1220 15.8
DEN/MORNIMITCHEN 1.708 22.2
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Wall Wnnd 324 0 n71 R_1q R -n 0 0 gn
Wall Wond 130 0.071 R_19 R-00 18090
Wall wood_ 604 0.071 R-19 R-0 0 270 An
Wall Wnnd 477 0071 R_19 R-0 0 An An
Rnnf Wnnd 1 470 0028 R-38 R_00 _0 n
Wall Wood 36 0071 R-19 —$-Q 315 An
Wall Wnnd 937 0071 R_19 R -D0 0 gn
Wall Wnnd 16n n 071 R-19 R-0 0_ 180 9n
Wall Wnor! 36 n 071 -19 R -n n 4580
Rnnf Wond 1 290 0.028 R_38 R-0 n _�_0
Wall Wopd_ 69 X 071 R_19 R-�n_ 925 90
Wall MLOob_ 69 0 071 R-19 R_n n_ _315_-90
WaII yllM-d— 89 x-071 R_19 R -n 0_ 180 An
Dnnr Nona 24 0 500 None R_0 0_ 180 _90
Wall Wnnd 59 _0.071 R_19 R -n 0 _0 9
Wall Wnnd 527 0071 R_19 R -n Q _ 270 _90
Wall Wnnd_ 106 n 071 R-19 R -n n _90 90
Rnnf Wnnd _ 1990 0 09R R-38 R_n n _ 0
Wall Wnnd 153 0071 R-19 --EL-0-0- 135 90
Wall Wood 59 _o 071 R_19 R_n n 225 90
Wall Wnod 52 _o 071 R_19 R-0 0 0 go
Wall Wond 196 0071 R_19 R -nn 1RD go
Wall Wnod 713 0071 R_19 R -a 0 270 90
Will Wnnd 180 0 071 R_19 R -n n --- qn gn
Wall Wnnd 59 0.071 R_19 R -nom_ 315�Q
Total Conditioned Floor Area:
Existing Floor Area:
Raised Floor Area:
Slab on Grade Area:
Average Ceiling Height:
Number of Dwelling Units:
7,216 ft2
n/a ft2
0 ft2
7,216 ft2
13.0 ft
1.00
Number of Stories: 1 1
# of Thermostat Vent
Units Zone Type Type Hgt. Area
_0 20_ Sleeping Sleep0ngc tal —2 n/a
018 Cnnditinned Seth;;rk —2 n/a
0.17 Conditioned Setback —2 n/a
0.24 Sleepung SleepingStat 2 n/a
Gains Condition
Y / N Status JA IV Reference Location / Comments
nergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Paoe:3 of 24 1
Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R
MR A-MB.S-JAMFS WFYMOI1TH
7,216
ft2
1/28120 9 ._.
Project Title
8081PORTOFINQ
I A QI JINTA
Raised Floor Area:
0
Date
Project Address
7,216
ft2
Average Ceiling Height:
Building Permit #
Rl1_ I1 ECJ-JANICA1
SYSTFMS_JNC_
1.00
(949) 453-1999
'Number of Stories:
Documentation Author
' .
Telephone
Plan Check/Date
Fnprmq PCD
(-A
CJin3ate 7nIlE15)
1 Field Check/Date
Compliance Method
Climate Zone
TDV
Standard
Proposed
Compliance
•(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.24
2.11
0.13
Space Cooling
63.62
61.12
2.50
Fans
9.04
10.79
-1.74
Domestic Hot Water
3.56
3.56
0.00
Pumps
0.00
0.05
-0.05
Totals
78.45
77.62
0.84
Percent better than Standard:
1.1%
BUILDING
COMPLIES - HERS
VERIFICATION REQUIRED
Building Type: [X—] Single Family ❑ Addition
❑ Multi Family ❑ Existing + Add/Alt
Building Front Orientation: (N) 0 deg
Fuel Type: Natural Gas
Fenestration:
Area: 1,740 ft Avg. U: 0.47
Ratio: 24.1% Avg. SHGC: 0.40
- BUILDING ZONE INFORMATION
Zone Name
Total Conditioned Floor Area:
7,216
ft2
Existing Floor Area:
n/a
ft2
Raised Floor Area:
0
ft2
Slab on Grade Area:
7,216
ft2
Average Ceiling Height:
13.0
ft
Number of Dwelling Units:
1.00
'Number of Stories:
1
' .
# of
Floor Area Volume Units Zone TvDe
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Rnnf Wood I Zns n n2A R -IR R -n n n n
Wall Wood 104 n_n7l R_19 R -n 0 _n gn
Wall Wood 238 n_n71 R_19 R -n n 18n gn
Wall Wnnd 7..9n n 071 R-19 R -n n go gn
Wall Wood 272 X71 R-19 R-0.0 925_ -
Roof Wood 1 598 0.028 13_38 R-0 0 _ 0
Gains Condition
Thermostat . Vent
Type Hgt. Area
GleepingStnt -2 n/a
Y / N Status JA IV Reference Location / Comments
El Naw-- 09 -AM 70NF3
❑New 09-A23 70NF 2
® ❑New 09-A23 70NF 2
®❑New 09-A23 70NE 2
®❑New 09-A23 ZONE 2
® ❑New 02-A2R ZONE 2
12331
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page:4 of 24 1
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
MR: &MRS. JAMESINEYMOIJTH --1/28/2009
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments
L Jndow Ernot /N) 9 0 0 290 NERD _0_a5 NERC 0 --q(Z New Fixed Glass
rAr/RFnl/C CRR
2
Window
Front
(N)
12.3 0.370 NFRC 0_27 NFRC 0 90 New Casement Glass
CAC/BED1/C0RR
3
Window
Front
(N)
12.3 0.370 NFRC 0_27 NFRC 0 90 New Casement Glass
CAC/BED1/CORR
4
Window
Front
(N)
4.0 0.290 NFRC 0_35 NFRC 0 90 New Fixed Glass
CAC/BED1/CORR
'5
Window
Front
(N)_
4.0 0.290 NFRC 0_35 NFRC 0 90 New Fixed Glass
CAC/BED1/C0RR
6
Window
Front
(N_
4.0 0.290 NFRC0 35 NFRC 0 90 New Fixed Glass
CAC/BED1/CORR
Z
Window
Front
(N)
4.0 0.290 NFRC 0.35 NFRC 0 90 New Fixed Glass
CAC/BED1/CORR
8
Window
Right
(W)
24.0 0.290 NFRC 0.35 NFRC 270 90 New Fixed Glass
CAC/BED1/C0RR
6
Window
Ri hcht
(W)
19.2 0.370 NFRC 0.27 NFRC 270 90 New Casement Glass
CAC/BED1/CORR
_M
Window
Right
(W)
19.2 0.370 NFRC 0_27 NFRC 270 90 New Casement Glass
CAC/BED1/CORR
11
Window
Right
(W)
19.2 0.370 NFRC 0.27 NFRC 270 90 New Casement Glass
CAC/BED1/C0RR
12
Window
Right
(W)
24.0 0.290 NFRC 0_35 NFRC 270 90 New Fixed Glass
CAC/BED1/CORR
13.
Window
Right
(W)
9.0 -DI90 NFR(J)35 NFRC 270 -,U New Fixed Glass
CAC/BED1/CORR
14
Window
Left
(E)
33.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass
CAC/BED1/CORR
15
Window
Left
(E)
4.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass
CAC/BED1/CORR
16
Window
Left
(E)
4.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass
CAC/BED1/CORR
17
Window
Left
(E)
30.2 0.290 NFRC 0_35 NFRC^ 90 90 New Fixed Glass
CAC/BED1/CORR
18
Window
Left
(E)
24.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass
CAC/BED1/CORR
1,Q
Window
Left
(FE)
3.3 0.290 NFRC 0.35 NFRC 90 90 New Fixed Glass
CAC/BED1/130RR
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166.
INTERIOR AND EXTERIOR SHADING
Area Thick. Heat Inside
(sf) (in.) Cap. Cond. R -Val.
Window Overhang Left Fin Riqht Fin
#
Exterior Shade Type
SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist Len Hgt
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
Ti
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
_
0.76
16
Bug Screen
0.76
17
Bug Screen
_
0.76
18
Bug Screen
_
0.76
19
Bug Screen
_
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Type
Area Thick. Heat Inside
(sf) (in.) Cap. Cond. R -Val.
JA IV Reference
Condition
Status
Location/
Comments
Concrete, Heavyweight
1,470
4.00 28 0_98 0
26-A1
New
CAC/BED1/C0RR / Slab on Grade
Concrete, Heavyweight
1,290
4.00 28 0_98 0
26-A1
New
ZONE5 / Slab on Grade
Concrete, Heavyweight
1,220
4.00 28 0_98 0
26-A1
New
ZONE4 / Slab on Grade
Concrete, Heavyweight
1.708
4.00 28 0.98 0
26-A1
New
ZONE3 / Slab on Grade
Concrete, Heavyweight
1,528
4.00 28 0_98 0
26-A1
New
ZONE 2 / Slab on Grade
PERIMETER
LOSSES
Insulation
Condition
Location/
Type
Length
R -Val. Location
JA IV Reference
Status
Comments
Slab Perimeter
142
None No Insulation
26-A1
New
CAC/BED1/CORR
Slab Perimeter
50
None No Insulation
26-A1
New
ZONE5
Slab Perimeter
80
None No Insulation
26-A1
New
ZONE4
Slab Perimeter
149
None No Insulation
26-A1
New
ZONE3
Slab Perimeter 119 None No Insulation 26-A1 New ZONE 2
Run Initiation Time: 01/28/09 13:23:08 Run Code: 1233177788
EnergyPro 4.4 by EnergySoft User Number. 2936 Job Number: Page:5 of 24
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
MR. .&_MRS-JAM ES -WEYMOUTH _. ___ __ -1/28/2009....._ .. _
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
20.
Windnw
Laft
(Fa
48.0 -0" NFRC -o 3?
21
Window
Right
(NW)
2.8 0.290 NFRC 0.35
22
Window
Right
(NW)
2.8 0.290 NFRC 0_35
23
Window
Front
(N)
60.0 0.290 NFRC 0.35
24
Window
Front
(N)_
2.8 0.290 NFRC 0_35
25
Window
Front
(N)
11.2 0.370 NFRC 0_27
2E
Window
Front
(N)
11.2 0.370 NFRC 0.27
27
_Window
Front
(N)
25.5 0.290 NFRC 0.35
2$
Window
Front
(N)
13.5 0.290 NFRC 0.35
2R
Window
Front
(N)
13.5 0.290 NFRC 0.35
M
Window
Rear
(S)
186.0 0.750 NFRC 0.59
31
Window
Rear
(S)
2.8 0.290 NFRC 0.35
M
Window Rear (S)
7-8 -D-29D NFRC: _Q_35
33
Window
Rear
(S)
2.8 0.290 NFRC 0.35
34
Window
Rear
(S)
2.8 0.290 NFRC 0.35
35
Window
Rear
(S)
2.8 0.290 NFRC 0.35
36
Window
Front
(NE)
2.8 0.290 NFRC 0.35
37
Window
Front
(NE)
2.8 0.290 NFRC 0.35
,U
_Window
Rear
(,SW)
48.0 0.480 NFRC 0.32
NER('. C)Q qQ Npw Sliding (,lass
(:A ./R D1/( 0RR
NFRC 315 90 New Fixed Glass
ZONE5
NFRC 315 90 New Fixed Glass
ZONE5
NFRC 0 90 New Fixed Glass
ZONE5
NFRC 0 90 New Fixed Glass
ZONE5
NFRC 0 90 New Casement Glass
ZONE5
NFRC -0 90 New Casement Glass
ZONE5
NFRC 0 90 New Fixed Glass
ZONE5
NFRC 0 90 New Fixed Glass
ZONE5
NFRC 0 90 New Fixed Glass
ZONE5
NFRC 180 90 New Pocket Sliders
ZONE5
NFRC 180 90 New Fixed Glass
ZONE5
NFRC; 180 qQ New Fixed Glass
70NE5
NFRC 180 90 New Fixed Glass
ZONE5
NFRC 180 90 New Fixed Glass
ZONE5
NFRC 180 90 New Fixed Glass
ZONE5
NFRC; 45 90 New Fixed Glass
ZONE5
NFRC 45 90 New Fixed Glass
ZONE5
NFRC 225 90 New Sliding Glass
ZONE4
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613.
INTERIOR AND EXTERIOR SHADING
Window Overhanq Left Fin Right Fin
#
Exterior Shade Type
SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len Hgt.
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Buq Screen
0.76 _
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
_
0.76
29
Bug Screen
_
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
_
0.76
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
_
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
Run Initiation Time: 01/28/09 13.23.08 Run Code: 1233177788
EnergyPro 4.4 by EnergySoft User Number. 2936 Job Number: Page:6 of 24
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
MR. --&-MRS. JAMES -WEYMOUTH _ - ----_---..-_____-- .. _ -_ _ -.:1/28/2009
Project Title Date
FENESTRATION SURFACES
Insulation
Condition
Location/
Type Length R -Val.
Location
True Cond.
Location/
#
Type
Area U-Factorl SHGC2
Azm. Tilt Stat. Glazing Type
Comments
33
_!Ins 0w_ Rlght_(NW
48 D. 0 48D NERC 0-32 NERC _31`9 __q9_ New Sliding rlacc
ZONE4
40
Window Right (W)_
16.5 0.290 NFRC 0_35 NFRC
270 90 New Fixed Glass
ZONE4
41
Window Right (W)
16.5 0.290 NFRC 0_35 NFRC
270 90 New Fixed Glass
ZONE4
42
Window Right (W)
24.0 0.290 NFRC 0.35 NFRC
270 90 New Fixed Glass
ZONE4
43
Window Right (W)
3.3 0.290 NFRC 0_35 NFRC
270 90 New Fixed Glass
ZONE4
44
Window Right (W)-
16.5 0.290 NFRC 0_35 NFRC
270 90 New Fixed Glass
ZONE4
45
Window Right (W)
7.0 0.370 NFRC 0_27 NFRC 270 90 New Casement Glass
ZONE4
46
Window Left (E)
24.0 0.290 NFRC 0.35 NFRC
90 90 New Fixed Glass
ZONE4
A7
Window Left (SE)
30.0 0.750 NFRC 0-59 NFRC 135 90 New Pocket Sliders
ZONE3
Aa
Window Left (SE)
38.0 0.290 NFRC 0_35 NFRC 135 90 New Fixed Glass
ZONE3
A9_
Window Left (SE)
32.0 0_290 NFRC 0_35 NFRC
135 90 New Fixed Glass
ZONE3
50
Window Left (SE)
6.7 0.290 NFRC 0_35 NFRC
135 90 New Fixed Glass
ZONE3
,1
Window aear S_W
32,Q 029 NFRQ J)_35 FRC 225 __U New Fixed Glass
70NE3
52
Window Rear (SW)
6.7 0.290 NFRC 0_35 NFRC
225 90 New Fixed Glass
ZONE3
53
Window Rear (S)
103.0 0.750 NFRC 0_59 NFRC
180 90 New Pocket Sliders
ZONE3
54
Window Rear (S)
32.0 0.290 NFRC 0_35 NFRC
180 90 New Fixed Glass
ZONE3
55
Window Rear (S)
6.7 0.290 NFRC 0_35 NFRC,
180 90 New Fixed Glass
ZONE3
56
Window Right (W)
32.0 0.290 NFRC 0635 NFRC
270 90 New Fixed Glass
ZONE3
JZ
Window Right (W)
6.7 0.290 NFRC 0.35 NFRC 270 90 New Fixed Glass
ZONES
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING
Window
Overhanq Left Fin Right Fin
#
Exterior Shade Type
SHGC Hgt. Wd.
Len. Hgt. I -Ext. REA Dist. Len.
Hgt. Dist. Len. Hgt.
39
Bug Screen
0.76
40
Bug Screen
0.76
41
Bug Screen
0.76
42
Bug Screen
0.76
43
Bug Screen
0.76
44
Bug Screen
0.76
45
Bug Screen
0.76
46
Bug Screen
0.76
47
Bug Screen
0.76
48
Bug Screen
0.76
49
Bug Screen
0.76
50
Bug Screen
0.76
51
Bug Screen
0.76
52
Bug Screen
0.76
53
Bug Screen
0.76
54
Bug Screen
0.76
55
Bug Screen
0.76
56
Bug Screen
0.76
57
Bug Screen
0.76
THERMAL
MASS FOR
HIGH MASS DESIGN
Area Thick.Heat Inside
Condition
Location/
Type
(sf) (in.) Cap. Cond. R -Val.
JA IV Reference Status
Comments
PERIMETER LOSSES
Insulation
Condition
Location/
Type Length R -Val.
Location
JA IV Reference Status
Comments
Run Initiation Time: 01/28/09 13:23:08 Run Code: 1233177788
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page: 7 of 24
Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R
MR --&-MRS. JAMES -WEYMOUTH-
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U -Factor' SHGCz Azm. Tilt Stat. Glazing Type Comments
,9
Window
Right
(W)
250 _0_3D -HR(; -027 NFRC; 270 _gg_ New CacemPnt Glacc
70NF3
59
Window
Right
(W)
10.0 0.370 NFRC 0.27 NFRC 270 90 New Casement Glass
ZONE3
60
Window
Left
(E)
180.0 0.750 NFRC 0_59 NFRC 90 90 New Pocket Sliders
ZONE3
61
Window
Right
(NW)
32.0 0.290 NFRC 0_35 NFRC 315 90 New Fixed Glass
ZONE3
•62
Window
Right
(NW)
6.7 0.290 NFRC 0_35 NFRC 315 90 New Fixed Glass
ZONE3
63
Window
Rear
(S)_
48.0 0.290 NFRC 0_35 NFRC 180 90 New Fixed Glass
ZONE 2
64
Window
Left
(E)
40.0 0.480 NFRC 0.32 NFRC 90 _ 90 New Sliding_Glass
ZONE 2
65
Window
Left
(E)
7.0 0.370 NFRC 0.27 NFRC 90 90 New Casement Glass
ZONE 2
LE
Window
Left
(E)
48.0 0.480 NFRC JLU NFRC 90 90 New Sliding Glass
ZONE 2
LZ
_Window
Left
(E)
48.0 0.480 NFRC 0.32 NFRC 90 90 New Sliding Glass
ZONE 2
_$
Window
Left
(E)_
10.5 0_370 NFRC 0_27 NFRC 90 90 New Casement Glass
ZONE 2
69
Window
Left
(E)
7.0 0.370 NFRC 0.27 NFRC 90 90 New Casement Glass
ZONE 2
M
Window
Rear
(SW)
80.0 0.480 NFRC J1,32 NFRC _225_ -9D- New Skiing Glass
ZONE 2
71
Window
Rear
(SW)
2.8 0.290 NFRC 0_35 NFRC 225 90 New Fixed Glass
ZONE 2
72
Window
Rear
(SW)
2.8 0.290 NFRC 0_35 NFRC 225 90 New Fixed Glass
ZONE 2
73
Window
Rear
(SW)
2.8 0.290 NFRC 0_35 NFRC 225 90 New Fixed Glass
ZONE 2
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B.
INTERIOR AND EXTERIOR SHADING
Window Overhang Left Fin Right Fin
#
Exterior Shade Type
SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt.
58
Bug Screen
0.76
59
Bug Screen
0.76
60
Bug Screen
0.76
61
Bug Screen
0.76
62
Bug Screen
0.76
63
Bug Screen
0.76
64
Bug Screen
0.76
65
Bug Screen
0.76
66
Buq Screen
0.76
67
Bug Screen
0.76
68
Bug Screen0.76
69
Bug Screen
0.76
70
Bug Screen
0.76
71
Bug Screen
_
0.76
72
Bug Screen
0.76
73
Bug Screen
0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Type Len
Insulation
R -Val. Location JA IV Reference
Condition Location/
Status Comments
Run Initiation Time: 01/28/09 13:23:08 Run Code: 1233177788
EnergyPro 4.4 by EnergySoft User Number. 2936 Job Number. Page:8 of 24
Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R
MR. &MRS. JAMES WEYMOUTH
- -
Energy
-
..-1/28/2009
Project Title
Location
Heating
Cooling
Date
R -Value Status
Tested?
HVAC SYSTEMS
Ducted
Ducted
Attic
4.2 New
No
GREAT RM./ DINING/FOYE
Ducted
Heating
Minimum
Cooling
Minimum
Condition
Thermostat
Location
Type
Eff
Type
Eff
Status
Type
CASITAS/BED/COR
Central Furnace
80% AFUE
Split Air Conditioner
14.0 SEER
New
Setback
GREAT RM./ DINING/FOYE
Central Furnace
80% AFUE
Split Air Conditioner
14.0 SEER
New
Setback
BED2 / OFFICE
Central Furnace
80% AFUE
Split Air Conditioner
14.0 SEER
New
Setback
HVAC DISTRIBUTION
Hydronic Piping pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated
Tank
Energy
Duct
Duct Condition
Ducts
Location
Heating
Cooling
Location
R -Value Status
Tested?
CASITAS/BED/COR
Ducted
Ducted
Attic
4.2 New
No
GREAT RM./ DINING/FOYE
Ducted
Ducted
Attic
4.2 New
No
BED2 / OFFICE
Ducted
Ducted
Attic
4.2 New
No
Hydronic Piping pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated
Tank
Energy
Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Standby R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE
Loss (%) Ext.
A.O.Smith FSG -100 Small Gas Recirc/Demand 1 75,000
100
New 0.60
n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
REMARKS
CONTRACTOR IS PROVIDING AND SIZING THE A/C SYSTEM SEE MECHANICAL DRAWINGS FOR SIZES AND ZONES.A/C SEER TO BE MIN. 14,
FURNACE AFUE MIN. 80%.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: A + A GROUP ARCHITECTS
Address: 20341 SW BIRCH ST. # 320
NEWPORT BEACH CA 92660
Telephone: 949-N5019O9t Lic. #: 't
(signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature) (date)
4.4
Documentation Author
Name: OMID TOHIDIAN
Title/Firm: BUILDING MECHANICAL SYSTEMS, INC.
Address: 410 GODDARD
Telephone:
Go
T
W
No tri, 0
HA
OF r AL1F
(date)
Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R
-MR.-&-MRS.- JAMES' -WEYMOUTH
Project Title Date
HVAC SYSTEMS
Heating
Minimum
Cooling
Minimum
Condition
Thermostat
Location Type
Eff
Type
Eff
Status
Type
DEN/MORN/KITCHEN Central Furnace
80% AFUE
Split Air Conditioner
14.0 SEER
New
Setback
MSTR/GYM Central Furnace
80% AFUE
Split Air Conditioner
14.0 SEER
New
Setback
HVAC DISTRIBUTION
Location
Duct
Coolina Location
DEN/MORN/KITCHEN Ducted Ducted Attic
MSTR/GYM Ducted Ducted Attic
Hydronic Piping pipe Pipe Insul.
System Name Length Diameter Thick.
Duct Condition
Ducts
R -Value Status
Tested?
4.2 New
No
4.2 New
No
WATER HEATING SYSTEMS Rated Tank Energy Tank Insul.
Water Heater # in Input Cap. Condition Factor Standby R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext.
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
REMARKS
-ONTRACTOR IS PROVIDING AND SIZING THE A/C SYSTEM SEE MECHANICAL DRAWINGS FOR SIZES AND ZONES.A/C SEER TO BE MIN. 14,
=URNACE AFUE MIN. 80%.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: OMID TOHIDIAN
Title/Firm: A+ A GROUP ARCHITECTS Title/Firm: BUILDING MECHANICAL SYSTEMS, INC.
Address: 20341 SW BIRCH ST. # 320 Address: 410 GODDARD
NEWPORT BEACH, CA 92660 IRVINE, CA 92618
Telephone: 949-250-1909 Lic. #: Telephone: (949) 453-1999
(signature)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(date) (signature)
(signature) (date)
(date)
Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R
MR. &'MRS. JAMES -WEYMOUTH - 1128/2009
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
The HVAC System "CASITAS/BED/COR" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design - Verify Thermal Mass: 1470 sqft Exposed Slab Floor, 4.00" thick at cas.& bdrm.1/ baths/ corr.
HIGH MASS Design - Verify Thermal Mass: 1290 sqft Exposed Slab Floor, 4.00" thick at grtrm./dinng./foyr./pwdr.
HIGH MASS Design - Verify Thermal Mass: 1220 sqft Exposed Slab Floor, 4.00" thick at bed rm. 2/bath2 &3/office/corr.
The HVAC System "DEN/MORN/KITCHEN" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design - Verify Thermal Mass: 1708 sqft Exposed Slab Floor, 4.00" thick at den/mrngrm./kit./bar/pnt./pw.
The HVAC System "MSTR/GYM" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design - Verify Thermal Mass: 1528 sqft Exposed Slab Floor, 4.00" thick at Master Suite & Gym
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a
HERS provider using approved testing and/or verification methods. Plan Field
The HVAC System "CASITAS/BED/COR" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion Valve.
The Cooling System "3.5 TON HVAC SYSTEM " includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify
the installation of the correct Condenser.
The HVAC System "GREAT RM./ DINING/FOYE" incorporates a HERS verified Refrigerant Charge test or a HERS verified
Thermostatic Expansion Valve.
The Cooling System "5 TON HVAC SYSTEM" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the
installation of the correct Condenser.
The HVAC System "BED2 / OFFICE" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion Valve.
The Cooling System "3.5 TON HVAC SYSTEM " includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify
the installation of the correct Condenser.
The HVAC System "DEN/MORN/KITCHEN" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic
Expansion Valve.
The Cooling System "5 TON HVAC SYSTEM" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the
installation of the correct Condenser.
The HVAC System "MSTR/GYM" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
The Cooling System "5 TON HVAC SYSTEM" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the
installation of the correct Condenser.
I EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page: 11 of 24 1
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE= Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements,from'the Certificate of Compliance supercede the-itemsmarked•with an asterisk (')-below. -When this checklist is incorporated -into the -permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
thev are shown elsewhere in the documents or on this checklist only.
Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE -
DESCRIPTION
permit application documentation. N/A DESIGNER MENT
Building Envelope Measures
w§ 150(a):
Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b):
Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
•§ 150(c):
Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
❑
apply to exterior mass walls).
❑
❑
❑
•§ 150(d):
Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
0
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
❑
❑X
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
❑x
❑
b. outside airintake with damper and control, flue damper and control
Elf
❑X
El
2. No continuous burning gas pilot lights allowed.
❑
❑X
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑
❑
§ 150(g): Vapor barriers mandatory iri Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ,
❑
❑
❑
permeance rate no greater than 2.0 permfinch.
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑
❑
'CF -6R Form:
❑
0
❑
§ 1.16-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑X
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
❑
Q
❑
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑X
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑X
❑
§ 1500): Water system pipe and tank -insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
0
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
Q
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number.
Page: 12 of 24
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the -Certificate of-Compliance*supercede the items marked with an asterisk (')-below- When-this-checklistis-incorporated into -the -permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or
tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support
platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions
in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑
duct tapes unless such tape is,used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers. ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
�010_1
❑ ❑
® ❑
❑ ❑
® ❑
❑ ❑
❑ ❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
®
❑
§ 118 (i): Cool Roof material meets specified criteria -
❑ ❑ ❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ❑ ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric
and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ ❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑X ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ FX ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled
❑ ❑X ❑
by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑ ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680
locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d).
EnergyPro 4.4 by EnergySoft_ User Number: 2936 Job Number.
Page: 13 of 24
Residential Kitchen Lighting Worksheet WS -5R
.1/28/2009__._ _. _ ..-...._
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires
as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity' Watts Other Watts
50w Low Voltage Halogen Yes X No 55.0 x_ 8 = 440 or
(2) 18w Fluorescent Downlights Yes X I No 1 42.0 x 10 = 420 or
14w Linear Fluorescent T5 Elec Yes X1 No 1 18.0 x 10 = 180 or
Yes No x = or
Yes No x = or
Yes No x' = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Total A: 1,040 B: 0
COMPLIES IF A;-> B YES ® NO ❑
EnergyPro 4.4 by Energysoft User Number. 2936 Job Number: Page: 14 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME -DATE
MR. &MRS. JAMES 1NEYMOUTH __ - 1/28720.09-
SYSTEM NAME FLOOR AREA
CASITAS/BED/COR 1,470
Number of Systems
1
Heating System
Output per System
35,000
Total Output (Btuh)
35,000
Output (Btuh/sgft)
23.8
Cooling System
Output per System
36,000
Total Output (Btuh)
36,000
Total Output (Tons)
3.0
Total Output (Btuh/sgft)
24.5
Total Output (sgft/Ton)
490.0
Air System
CFM per System
800
Airflow (cfm)
800
Airflow (cfm/sgft)
0.54
Airflow (cfmrron)
266.7
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
82
22,331
-62
551
20,486
48.0 46.1 of
0
O s
3,972
2,628
0
0
0
0
0
0
0
0
Supply Fan Cooling Coil
0
31972
1 2,628
30,276 -62 25,743
HVAC EQUIPMENT SELECTION
3.5 TON HVAC SYSTEM 29,698 0 35,000
Total Adjusted System Output 29 698 0 35,000
(Adjusted for Peak Design Condition's)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
AEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26.0 of 66.9 of 66.9 of 107.7 of
10 :F5 Supply Air Ducts
lo -
Outside Air rri:
0 cfm 104.7 of
Supply Fan Heating Coil
800 cfm ROOMS
70.0 of
66.9 OF I
Return Air Ducts
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures
at Time of Cooling
Peak
111.0172.4 of
82.6 60.2 of 82.6 ' 60.0 of -
48.0 46.1 of
O s
Supply Air Ducts
Outside Air
0 cfm
Supply Fan Cooling Coil
52.6 48.2 of
800 cfm
ROOMS
29.7% R.H.
78.0/58 OF
82.6/60.2 0
.5
Return Air Ducts
I
EnergyPro 4.4 by EnergySoft
User Number: 2936
Job Number.
Page:15 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME.....
-MR: &-MRS. JAMES WEYMOUTH ..... _-1728/2009_ ._ .
SYSTEM NAME FLOOR AREA
GREAT RM./ DINING/FOYE 1,290
EATING SYSTEM PSYCH
26.0 of 69.0 of
Outside Air
0 cfm
Supply Fan
2000 cfm
69.0 of
69.0 of
SYSTEM LOAD
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
1,162
23,582
43
519
17,042
0
4,195
2,187
0
0
0
0
0
0
0
0
0
4,195
2,187
31,97 43 21,415
5 TON HVAC SYSTEM 48,987 2,486 70,000
Total Adjusted System Output 48,987 .2,486 70,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
-eam Temperatures at Time of Heating Peak)
101.6 of
Supply Air Ducts
Heating Coil 100.6 of
ROOMS
70.0 of
K Return Air Ducts `4
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 72.4 of 80.0 / 62.6 of 80.0 62.5 °F 57.1 / 54.2 of
".r•4 Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 59.1 / 55.0 of
2000 cfm 40.2% R.H. ROOMS
80.0/62.6 of 78.0: 62.0 of
Return Air Ducts I
. L EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page: 16 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME - DATE
_ ___.___.MR:..& MRS. JAMES -WEYMOUTH _...._ --1/28/2009
SYSTEM NAME FLOOR AREA
BED2 / OFFICE 1,220
SYSTEM LOAD
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
624
17,995
84
446
17,070
EATING SYSTEM PSYCHROMETRICS
0
Peak
26.0 OF
3,201
2,190
0
0
0
0
0
0
0
0
0
3,201
2,190
24,396 84 F 21,451
HVAC EQUIPMENT SELECTION
3.5 TON HVAC SYSTEM 29,480 0 35,000
Total Adjusted System Output 28,480 0 35,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am
Note: values above
given at ARI conditions
EATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26.0 OF
67.4 OF 67.4 OF
108.3 OF
:40
Supply Air Ducts
Outside Air
0 cfm
105.7 °F
Supply Fan Heating
800 cfm
Coil
ROOMS
70.0 OF
67.4 OF
111.0.! 72.4 OF
Outside Air
0 cfm
81.7: 59.7 °F
EnergyPro 4.4
�% Return Air Ducts `+
ROMETRICS (Airstream Temperatures at Time of Cooling Peak
81.7 % 59.7 OF 81 7 / 59.5 OF "v 47 4 145 5 of
Supply Fan
800 cfm
User Number: 2936
Cooling Coil
Return Air Ducts F'
Job Number:
Supply Air Ducts
51.1 / 47.2 OF
29.2% R.H. ROOMS
78.0158.3 OF
I
17 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME . DATE
.. __ - _.-----MR. ----MR.--&-MRS-.'JAMES WEYMOUTH _. - - . __ _.. _ _ _ - - 1%2872009
SYSTEM NAME FLOOR AREA
DEN/MORN/KITCHEN 1,708
GINEERI
Number of Systems
1
Heating System
Output per System
70,000
Total Output (Btuh)
70,000
Output (Btuh/sqft)
41.0
Cooling System
Output per System
60,000
Total Output (Btuh)
60,000
Total Output (Tons)
5.0
Total Output (Btuh/sqft)
35.1
Total Output (sgftrron)
341.6
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.17
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.0
Outside Air (cfm/sqft)
0.00
)te: values above given at ARI conditions
:ATING SYSTEM PSYCHROME
26.0 of 68.2 of
c'
Outside AirO ,r
t.;
0 cfm
Supply Fan
2000 cfm
68.2 OF
SYSTEM LOAD
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
iSensiblel
Latent
I CFM
I Sensible
2,048
38,057
-202
984
30,569
0
6,769
3,922
0
0
0
0
0
0
0
0
0
6,7691
3,922
51,595 202 38 413
HVAC EQUIPMENT SELECTION
5 TON HVAC SYSTEM 50,695 1,037 70,000
Total Adjusted System Output 50,695 1,037 70,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm . Jan 12 am
ream Temperatures at Time of Heatina Peak)
68.2 of 100.8 of
Heating Coil
11 Return Air Ducts 4
Supply Air Ducts
99.0 OF
ROOMS
70.0 OF
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 72.4 of 81.2 162.9 of 81.2 , 62.8 °F 57.5/54.30f
Supply Air Ducts
Outside Air Is
0 cfm Supply Fan Cooling Coil 60.7 155.6 OF
2000 cfm 39.9% R.H. ROOMS
81.2! 62.9 of 78.0 161.9 of
Return Air Ducts < I
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. _ Page: 18 of 24
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAMEDATE
__. -1/28/2009
SYSTEM NAME FLOOR AREA
MSTR/GYM 1,528
(STEM
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
FSensible
1,464
28,827
96
633
20,482
0
5,128
2,628
0
0
0
0
0
0
0
0
0
5,128
2,628
39,083 -96 25 738
HVAC EQUIPMENT SELECTION
5 TON HVAC SYSTEM 49,636 1,918 70,000
.Total Adjusted System Output qg s36 1,918 70,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm C Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 OF 68.8 OF 68.8 OF 17
101.4 OF
Outside Air
Supply Air Ducts
QV
0 cfm 100.2 OF
Supply Fan Heating Coil
2000 cfm ROOMS
68.8 OF 70.0 °F
DOLING SYSTEM PSYCHROMETRICS Airstream 1
111.0 172.4 OF 80.4 / 62.7 OF 80.4 / 62.6 OF
b 64
Outside Air 1,
0 cfm
80.4/62.7 °F
JnergyPro 4.4
Return Air Ducts `4
watures at Time of Coolin
57.2/54.3°F
Supply Fan Cooling Coil
2000 cfm
User Number: 2936
h Return Air Ducts '4
Job Number.
Supply Air Ducts
59.6155.2 OF
40.0% R.H. ROOMS
78.0; 61.9 OF
19 of 24
ROOM LOAD SUMMARY
PROJECT NAME
---MR*. -& MRS. JAMES
DATE
_._1728/2009
----17Z8/2009-'
SYSTEM NAME
CASITAS/BED/COR
FLOOR AREA
1,470
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
CAC/BED1/CORR
cas.& bdrm.1/ baths/ corr.
1
821
22,331
-62
821
22,331
-62
551
20,486
PAGE TOTAL r 821 F22,3311 -62 551 20,486
TOTAL 1 821 22,331 -62 551 20,486
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page: 20 of 24
ROOM LOAD SUMMARY
PROJECT NAME
-_-- MR7&-MRS: JAMES__WEYMOUTH
DATE
--- -1128/20-0-9
SYSTEM NAME
GREAT RM./ DINING/FOYE
FLOOR AREA
1,290
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE5
g rtrm./d in ng./foyr./pwd r.
1
1,162
23,582
43
1,162
23,582
43
519
17,042
PAGE TOTAL 1 1,162 23,582 43 519 17,042
TOTAL 1 1,162 23,582 43 519 17,042
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page: 21 of 24
ROOM LOAD SUMMARY
PROJECT NAME
_ _ . MR. &-MRS: JAMES -WEYMOUTH _
DATE
--'1728/2099
SYSTEM NAME
BED2 / OFFICE
FLOOR AREA
1,220
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE4
bedrm.2/bath2&3/office/corr.
1
624
17,995
84
624
17,995
84
446
17,070
PAGE TOTAL 1 624 17,9951 84 446 17,070
TOTAL 1 624 17,995 84 446 17,070
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page: 22 of 24
ROOM LOAD SUMMARY
PROJECT NAMEDATE
MRS -JAMES -WEYMOUTH--- _.._........ __ _ .._ _.._. _ __... ....._._-_.1/28%2009_..
- - --- �MR. & .
SYSTEM NAME
DEN/MORN/KITCHEN
FLOOR AREA
1,708
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE3
den/m rng rm./kit./bar/pnt./pw.
1
2,048
38,057
-202
2,048
38,057
-202
984
30,569
PAGE TOTAL 2,048 38,057 -202 1984 30,569
TOTAL 1 2,048 38,057 -202 984 30,569
EnergyPro 4.4 by EnergySoft User Number. 2936. Job Number Page:23 of 24
ROOM LOAD SUMMARY
PROJECT NAME
-- - -- MR: &'MRS:_JAMES-WEYMOUTH-. _
DATE
- -112872009
SYSTEM NAME
MSTR/GYM
FLOOR AREA
1,528
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE 2
Master Suite &Gym
1
1,464
28,827
-96
1,464
28,827
-96
633
20,482
PAGE TOTAL 1,464 28,827 -96 633 20,482
TOTAL 1 1,464 28,827 -96 633 20,482
EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page:24of 24