Loading...
08-1954 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 6*4 0G 08-00001954' 80815 VIA PORTOFINO 777-150-022- - - DWELLING - SINGLE FAMILY LOW DENSITY RESIDENTIAL 618834 T4-tyl 4 44ulk& BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: JAMES & ROBERTA WEYM 1445 EVERGREEN POINT DETACHED MEDINA, WA 98039 Arcl itect or En ineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: �- 'c seNo.: 769229 Date: b 'Contractor: OWNER- UILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERNUT Contractor: ALBERS CONSTRUCTION 78060 CALLE ESTADO,. LA QUINTA, CA 92253 (760)771-9954 Lic. No.: 769229 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/17/09 d �d SUITE 1.` :` 'e f WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the. work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0004885-2008 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become sub' c to the workers' compensation provisions of Section 3700 of Labor Code all f/y h it comply with those provisions. Date: : 2 v4 Applicant: L p WARNING: FAILURE TO SECURE WORKERS' C011FENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above 'nformation is correct. I agree to comply with all city and county ordinances and state laws r�eellaatttiii to building co struction, and hereby authorize representatives of this county to enter upon the abov -me)r "S prop2rty f r' spection purposes. Date: Signature (Applicant ent). Application Number . . . . . 08-00001954 ------ Structure Information 7216 SF SFD ----- Other struct info . . . . . CODE EDITION 2007 # BEDROOMS 5.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1145.00 PATIO SQ FTG 1003.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 7216.00 Permit . . . BUILDING PERMIT Additional desc . . 7216 SF SFD Permit Fee . . . . 2396.50 Plan Check Fee 1557.73 Issue Date . . . . Valuation . . . . 618834 Expiration Date . . 8/16/09 Qty Unit Charge Per Extension BASE FEE 2039.50 119.00 ---------------------------------------------------------------------------- 3.0000 THOU BLDG 500,001-1,000,000 357.00 Permit . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 325.52 Plan Check Fee 81.38 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/16/09 Qty Unit Charge Per Extension BASE FEE 15.00 7216.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 252.56 2148.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 42.96 1.00 ---------------------------------------------------------------------------- 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . .. MECHANICAL Additional desc . . Permit Fee . . . . 243.50 Plan Check Fee 60.88 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1 8/16/09 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 3.00 11.0000 EA MECH FURNACE >100K 33.00 5.00 22.5000 EA MC B/C >15 <=30HP/500K-lM BTU 112.50 9.00 6.5000 EA MECH VENT FAN 58.50 1.00 6.5000 'EA MECH EXHAUST HOOD 6.50 LQPERMIT - Application Number . . . 08-00001954 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 225.00 Plan Check Fee 56.25 Issue Date . . . . Valuation . . 0 Expiration Date . . 8/16/09 Qty Unit Charge Per Extension BASE FEE 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 3.00 6.0000 EA PLB ROOF DRAIN 18.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 14.00 .7500 EA PLB GAS PIPE >=5 10.50 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/16/09 Qty Unit Charge Per Extension BASE FEE 15.00 -------------------------------------------------- Special Notes and Comments 7,216 SF SINGLE FAMILY DWELLING.1145 SF GARAGE, 1003 SF COV. PATIO. 2007 CODES. 2G06 D.I.F. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, WATER FEATURES and -----------=---------------------------------------------------------------- BBQ'S** Other Fees . . . . . . . . . ART IN PUBLIC PLACES-RES 1047.08 DIF COMMUNITY CENTERS-RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 155.77 DIF FIRE PROTECTION-RES 140.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 61.88 DIF STREET MAINT FAC-RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due LQPERMIT Application Number ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total . . 08-00001954 3205.52 .00 .00 1756.24 1400.00 .00 5739.73 .00 .00 10701.49 1400.00 .00 3205.52 356.24 5739.73 9301.49 LQPERMIT o��-a-'"'�� Certificate of Occupancy. G OFTiBuilding & Safety Department This Certificate is issued pursuant to the requirements of Appendix Chapter 1 Section 110 of the 2007 California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-815 VIA PORTOFINO Use classification: SINGLE FAMILY DWELLING Occupancy Group: R=3 Type of Construction: VN Sprinklers Installed: NO Sprinklers Required: NO Building Official Building Permit No.: 08-1954 Land Use Zone: RL Occupant Load: 36 Owner of Building: JAMES & ROBERTA WEYMOUTH Address: 1445 EVERGREEN POINT RD City, ST, ZIP: MEDINA, WA 98039 By: STEVE TRAXEL Date: APRIL 13, 2010 RECORDING REQUESTED BY: SOUTHLAND TITLE - INLAND EMPIRE (Title) AND WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: James L. Weymouth and Roberta S. Weymouth 1445 Evergreen Point Road Medina, WA 98039 Order No.: 67623664 Escrow No.: P013509-CY A.P.N.: 777-154422 M4 &2o DOC # 2008-0096023 02/27/2008 08:00A Fee:10.00 Page 1 of 2 Coo T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk d Recorder 1111111111111111111111111111111111111111111111111 S R U PAGE SIZE OA I MISC I LONG RPO I COPY M A L 485 428 1 tbO2NCORJ SMF NCHG UAV I T: UNI GRANT DEED t O THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $ 6024.1 D [ X ] computed on full value of property conveyed, or [ - ] computed on full value less value of liens or encumbrances remaining at time of sale.4 [ - ] unincorporated area [ X ] City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, Thomas R. Hudson and Donna L. Bucher -Hudson, Trustees of the Revocable Living Trust Agreement for Thomas R. Hudson and Donna L. Bucher -Hudson dated 8/10/98 t hereby GRANT(S) to James L. Weymouth and Roberta S. Weymouth, husband and wife as community property the following de cribed real property in the County of Riverside, State of California Lot 149 of Aalended Tract o. 9894-2, in the�&Ky ( 'f La Oulnta, CdupWof Riverside, S e of California, per map recon d in Book 327 a s) 5&8B, inciusa of Maps, in the Ice of the County Reo er of said Co nty. .�Rh: ht 1 t A Dated: February 7, 2008 STATE 0- Al " COUNTY OF 1�.N4L ) SS. On f"Y I'i 2009 before me - Ch/lA A ym.el-ra I F a Notary Public, personally appeared 'nbMA6 r2_ .tease J.I who proved to me on the basis of satisfaclory evidence to be the person(s) whose names) is/are subscribed to the within instrument and acknowledged to me that., he/she/lhey executed the same In his/herltheir authorized capacily(ies) and that by histher/lheir signature(s) on the instrument the person(s), or the entity upon behalf of which The person(s), acted, executed the Instrument. I certify under PENALTY OF PERJURY under -the laws of the State of California that the foregoing paragraph is true and correct WITNESS my hand and official seal. Signature Signature of Notary Thomas R. Hudson and Donna L. Bucher - Hudson, Trustees of the Revocable Living Trust Agreement for Thomas R. Hudson and Donna L. Bucher -Hudson dated 8/10198 By: Thomas R. Hudson, Trustee 2&0 :,ding -_amu �7 By: Donna L. Bucher -Hudson, Trustee Mopey AIpfIC Iiwo Of iNoggfqbri 111VAP0eM11Mod tom" Mq►10. Sol 1 meow (This area for official notary seal) U y I O MAIL TAX STATEMENTS AS DIRECTED ABOVE Public Record M File No. 67623864 EXHIBIT "N' All that certain real property situated in the County of Riverside, State of California, described as follows: Parcel 1: Lot(s) 149 of Amended Tract No. 29694-2, In the City of La Quinta, County of Riverside, State of California, as per Map recorded in Book 327 Page(s) 56 through 88 inclusive of Maps, In the office of the County Recorder of said County. Excepting therefrom to grantor, and its successors and assigns, Interest in all water, minerals, oil, gas, petroleum, other hydrocarbon substances and all geothermal energy sources in or under said land or which may be produced for said land. Parcel 2: Non-exclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. January 9, 2009 Mr. and Mrs. Jim Weymouth 1445 Evergreen Plant Road- Medina, oadMedina, WA 98034 RE: Weymouth /Final Design Review Lot 149 at 80815 Via Portofino" Dear Mr. and Mrs. Weymouth, The Hideaway Design Review Committee met to review your submittal of Final' Design plans for your Lot 149. You are approved to begin construction provided the following comments are addressed before the setback inspection. The plans will need to be reviewed and approved before the setback inspection can be scheduled. 1. The palm tree on the east end of the pool is located in the view corridor. 2. Please specify that the wattage is 25 maximum for the SPJ-14-02 light fixtures. 3.. Are pool and. spa equipment. located_ behind- walls, or in und_(zrgrou_nd.. vaults. to. contain noise, please specify.`�� 4. The building is over massed as the 20' allowable height is shown from the finished floor. It needs to be shown from the finished pad. If lowered, it would conform to. the guidelines. — hl-(� Alze Fy- y F'N, ?14p. 5. Please clarify on your next set of plans that the proposed walls are of a thickness to allow windows to be recessed at least 6" on street or golf facades and 2" on side facades and on the second floor elements. The details showing the minimum required recess 6" and 2 minimum onopenings are not drawn and are not keyed to the plan or elevations. '�, A) -4— ---, G/V 4S 6. Are the proposed doors, door frames and window frames wood clad or metal non - anodized finish? The schedules are not specific, please clarify. G,CV—t&1,-jCU)j-ev T Please note on the plans that the vents and flues will be minimized. cel A,!9 - /,j v re - ,!9 -More- o/ov +/, Any deviation from the Design Guidelines must be submitted with a request for Variance. If a design element is not presented as a Variance request and the committee inadvertently overlooks it during the review process it will be the design team's responsibility to make modifications at a later date if requested by the Design Review Committee. Please contact Mindy Gutierrez at (760) 393-5211 to schedule your preconstruction meeting. We look forward to working, with you on the construction of your new home. Sincerely, Hideaway Design Review Committee cc: DRC File, AA Group, Ray Martin, Bill Albers CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated& effective 6/26/2008. Green Sheet approvals are forwarded to the Buildinq & Safety Deoartment directly by Public. Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant.. 3%m 0)P_`lmOv-tVr- D.ate:_I-Vo-VC� Developer:- -CoN14AVrtq, Tract No-19&L1E2Jract Name: Lot No.(s): tyq Address(s :: _$o $i5 Via �a-w�,..►o Phone Number: -tba 1-1y- $1$"1 CO Lk Qu 4ra-rAr t<,0*_ The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: �• CUSTOM HOMES: PROVIDE ITEMS .#2, #3, #4 AND #5 BELOW ❖ TRACT HOMES: PROVIDE ITEMS W#2. #3, #4 (AS APPLICABLE) AND #6 BELOW •% COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1. #2. #3 AND #5 BELOW ❖ WALLS: PROVIDE ITEMS #7 BELOW �• SIGNS: PROVIDE ITEMS#8 BELOW OTHER: PROVIDE ITEM #9 BELOW 1. Attach Pad Elevation Certificates in compliance with. the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a.precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. (a._Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved eotechnical certification are exempt from this re .QN IS �Final ttach recorded final map or title informatio geeowing proposed building locations are legal lots. maps may be viewed at the following website: htto://www.la-auinta.org/PlanCheck/m search.asrx Attach a completed < 1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. Attach a copy of the precise grading plan to the Public Works Department showing building location(s). AO flood zone developments will require an approved flood plain development plan. 6. Attach an approved rough or precise grading plan for the building location(s) for pad elevation verification or City plan set number if available. Plans may be viewed at the following website: http://www.la-auinta.org/PlanCheck/m search.aspx 7. Attach wall plan &related approved grading plan. 8. Attach sign layout/plan & related precise grading/landscape plan. i 9. Attach supporting documentation for grease trap or special facility installations. have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my "aboveec ma be released for building permit issuance. Recommended by: Dated: C7 Public Works Distribution: L,-4"Green Sheet to Building & Safety . (_) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: Page 1 of 4 Project Information .. Project Contractor; -Project Phase (check,one) Project Name":VJ Ly r+ auT y R=es Ili EN ee Construction, 0 Demolition Project Tract, Number. Z 9'8q y '-^ Lot Numbers y Anticipated Start, Date: Project Street Address: 4,9'0 .815 • V1Ar P6(L-mF1 t4 o Anticipated Completion a y Date: 2. -15 -% t Total Acres in Active Construction (< 1 acre per Lot): . So AAe !•- Y'i `c " G (f Please "note: 'Dust control is required Project Contact Information regardless of construction status: Pers .control duringbusiness.and non-busine`* ,►.� AL.gERS r 1� p:es la Irl T r BeF.S Caesra-c.z;.a o �0 2 3 8 `�• ' .� OIN ''( Imo _ '1-11 - ctck 5 4`, s L "1(00 • - .7 n - 9 8 3 I Name: Titles Company Name: Mailing Address: e City: State:': Zip Code: Primary Phone #: Fax #: 24 Hour t i Access/Emergency �. ' bo `- '1ZK- 87 81 Phone_#. • -74 Cell Phone #: Email address: b. 0ilbw,rs_ ec �-1kl�nk�n�-• " PM10 Certificate #: 10 20 Fugitive Dust Control PM 10 Plan (< 1 acre per Lot or Infill Project) Plan Updated 6-26-08 This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401, 402, 201, 203 and Portable Equipment Registration Program (PERP). ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily. Water shall be applied from an adequate sized metered water source to dry soils to prevent: ■ . Visible dust emissions .>20% opacity. ■ Visible dust emissions that travel > 100 feet from the.source (within site) ■ Visible dust emissions that cross any property line EDUCATION: The responsible dust control Individual and -key personnel shall attend SCAQMD PM10 class and obtain PM10 certificate number prior to construction activity (training information may -be obtained by contacting SCAQMD at (909) 396-2183). ❖ CONSTRUCTION & DEMOLITION ACTIVITIES: A copy' of this approved Fugitive Dust Control Plan must be kept on site. I At least one short-term stabilization method must be used during off hours. At least one long-term stabilization measure must be used within ten (10) days of ceasing activity. WEATHER MONITORING: .Wind. predictions shall be monitored. 11- SIGNAGE: Approved signs shall be installed at. a highly visible location. Please refer to the Coachella Valley Fugitive Dust Control Plan. Handbook for Construction Signage Guidelines. •:� TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum traffic speed of 15mph :will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. _ •'r PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only. ❖ TRACK OUT: Provide 24, hour street cleaning and track out system as approved by City Public Works inspectors. No dirt on public or private. roads. Track out shall be cleaned up within one (1) hour of incident and at the conclusion of each Workday. DIRT PILES: Dirt piles shall be limited to 50 cubic yards .and built per California Building Code grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile or grading permit. FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of 'property and return 20 feet on either side if HOA restrictions apply. Block walls can replace PM10 fencing during the construction phase. EQUIPMENT: Extra hoses and sprinklers shall be maintained. on site.. , EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall. also be applied during excavation or grading operations. Page 3 of 4 Fugitive Dust Control PM 10 Plan (< 1 acre per Lot or Infill ' Project) Plan, Updated 6726-08 •# DUMP TRUCKS: Open top dump trucks shall be wet down, moist .and covered with a tarp prior to leaving site. ❖ INACTIVE .SITE: Within 10 days of ceasing of activities, re-vegetate or :permanently stabilize as required.. v RECORD KEEPING: Fugitive Dust Control. Plan records (i.e. self. inspection records, records of use of chemical suppressants, etc.) shall be maintained. for 3 .Years by the Property. Owner (or Authorized Representative). Property Owner shall notify the City and .SCAQMD within 10 days of completion of project. City of La Quinta — Site Specific Construction Phase PM10 Agreement Agreement Updated 6-26-08 The signature of the property owner (or authorized representative): ❖ Shall 'act as his/her acknowledgement of dust control requirements and- their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; 6 Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. The property owner (or authorized representative): - Acknowledges that dust control is required twenty-four 124) hoursa day; .seven (7) days a week, I throughout the-period of project performance, regardless of project size "or status; I ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of. the approved dust control " plan; :. :•. Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; �.� Shall authorize representatives of City/County to enter, upon the property for inspection and/or abatement purposes; and - Shall hold harmless the-City/County and its re' resentatives irom liability for any actions related to this dust control plan.or any City/County initiated abatement activities. T1�9 Signature of Property Owner or Authorized Representative Date AL8ere.s . Printed Name of Property Owner or Authorized Representative: -Title of Property Owner or Representative Company Name Phone Number e y =877 Page 3 of 4. inV N46 I January 23, 2009 P] File No.: 11415-01 Doc. No.: 09-01-793 This report is issued with the understanding that the owner, or the owner's representative, has the responsibility to bring the information and recommendations contained herein to the attention of the architect and engineers for the project so that they are incorporated into the plans and specifications for the project. The owner, or the owner's representative, also has the responsibility to take the necessary steps to see that the general contractor and all subcontractors follow such recommendations. It is further understood that the owner or the owner's representative is responsible for submittal of this report to the appropriate governing agencies. Earth Systems Southwest [ESSW] has striven to provide our services in accordance with generally accepted geotechnical engineering practices in this locality at this time. No warranty or guarantee is express or implied. This report was prepared for the exclusive use of the Client ,and the Client' s,.,authorized-agents. T_.t_- This report is based on the assumption that an adequate program of client consultation, construction monitoring, and testing will be performed during the final design and construction phases to check compliance with these recommendations. Maintaining ESSW as the geotechnical consultant from beginning to end of the project will provide continuity of services. The geotechnical engineering firm providing tests and observations shall assume the responsibility of Geotechnical Engineer of Record. Should you have any questions concerning our report please give us a call and we will be pleased to assist you. Sincerely, EARTH SYST ST G S- <0 iv Ool•yC•o9�` �/ CE 38234 z Craig S. Hill d Exp. 03/31/09 Z CE 38234s� civ► gOF CAl\ LTR/csh/ajm Distribution: 3/City of La Quinta Building & Safety Department 1/Mr. Jim Weymouth 1/Albers Construction Co., Inc. 1/RF Structural Consultants, Inc. 2/BD File EARTH SYSTEMS SOUTHWEST Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: James &-Roberta Weymouth ideaway) Owner's Name: James & Roberta Weymouth Project Address: 80-815 Via Portofino, La Quinta, CA Project Description: APN: 777-150-022 Type of Development: New Single Family Dwelling Date: 02/18/09 Phone No. (949) 361-0437 Tract #: 9,e — e Lot #'s: 109 Residential XX Commercial Industrial Total Square Feet of Building Area: 7216 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 02/18/09 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 • Requirement Number of Sq.Ft. 7,216 Sq. Ft._ Amount per Sq.Ft. $ 3.78 Amount Collected $ 27,276.48 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., SupportServices Certificate issued by: Leticia C. Torres, Facilities Analyst Signature: Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that t is District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance less 3% for Administrative Fees to process the reimbursement. LT:c/mydoes/devfees/certificate ofcompliance,form tablesTO USE.doc 1 9/11/08 02/17/2009 16:42 7607777011 LA QUINTA BLDG DEPT PAGE 01101 ' Building 8! Safety Department 78-495 Calle Tampico o� PO Box 1504 La Quinta, CA 92253 (760) 777-7012 voice (760) 777-7011 fax , CERTIFICATION OF BUILDING AREA' STREET ADDRESS OF JOB, 80-815 Via PORTOFINO APN: 777-150-022 DESCRIPTION OF WORK: New Single Family Dwelling SQUARE FOOTAGE: 17216 con ft: 2� 2� (o OWNER'S NAME: JAMES & ROBERTA WEYMOUTH . 1445 EVERGREEN POINT ROAD MEDINA, WA 98039 CITY OF LA __ _��� BUILDING & S �(11N�-a (Coachella Valley Unified School $'Tact • ? p AF�j�.OEP 83-733 Avenue 55 ~- Ap Fj0v1Z� T. P 0 Box 847 Thermal, CA 92274 pArE Z (760) 398 5909 !7 BY . Desert Sands Unified School DistrictV 47-950 Dune Palms Road Le Quinta, CA 92253 (760) 771-8595 Please Note: This Letter Verifies Conditioned Square Footage. Please call your School District to Verify School Fees, Requirement for Cashiers Check or Money Order and Hours of Operation. For questions regarding this letter, please call. - Philip Juarez, Counter Technician (760) 777-7092 -l" TITLE 24 REPORT Title 24 Report for: MR. & MRS. JAMES WEYMOUTH 80815 VIA PORTOFINO LA QUINTA, CA 92253 Project Designer: A + A GROUP ARCHITECTS 20341 SW BIRCH ST. # 320 NEWPORT BEACH, CA 92660 949-250-1909 Report Prepared By: OMID TOHIDIAN BUILDING MECHANICAL SYSTEMS, INC. 410 GODDARD IRVINE, CA 92618 (949) 453-1999 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTI N DATE BY* $ Joh Numhpr- 1 /28/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC- www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 2936 it • STT rc,� TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 12 Form WS -5R Residential Kitchen Lighting 14 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 20 EnergyPro 4.4 by EnergySoft Job Number: User Number: 2936 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R MR-' MRS .IAN].ESMEYMOHIH -- . _ ... _ -1/2$/2009 Project Title Date 80815 VIA PORTOFIND I A CJl11NTA Project Address Building Permit # _BU11 DING MECHANIC'Al SYSTEMS,1 (949) 453-1999 Documentation Author Telephone Plan Check/Date rqyPm CSA (Timate 7pne 15 I Field Check/Date Complia Method Climate Zone TDV Standard Proposed Compliance ykBtu/sf-yr) Design Design Margin Space Heating 2.24 2.11 0.13 Space Cooling 63.62 61.12 2.50 Fans 9.04 10.79 -1.74 Domestic Hot Water 3.56 3.56 0.00 Pumps 0.00 0.05 -0.05 Totals 78.45 77.62 0.84 Percent better than Standard: I BUILDING COMPLIES - HER Building Type: W Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (N) 0 deg Fuel Type: Natural Gas Fenestration: Area: 1,740 ft2 Avg. U: 0.47 Ratio: 24.1% Avg. SHGC: 0.40 BUILDING ZONE INFORMATION Zone Name Floor Area Volume rASITAS/BFn/CnR 1470 X911 -GREAT RM / DININR/FOYE 1,99 16.7 BB DQE 1220 15.8 DEN/MORNIMITCHEN 1.708 22.2 OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 324 0 n71 R_1q R -n 0 0 gn Wall Wond 130 0.071 R_19 R-00 18090 Wall wood_ 604 0.071 R-19 R-0 0 270 An Wall Wnnd 477 0071 R_19 R-0 0 An An Rnnf Wnnd 1 470 0028 R-38 R_00 _0 n Wall Wood 36 0071 R-19 —$-Q 315 An Wall Wnnd 937 0071 R_19 R -D0 0 gn Wall Wnnd 16n n 071 R-19 R-0 0_ 180 9n Wall Wnor! 36 n 071 -19 R -n n 4580 Rnnf Wond 1 290 0.028 R_38 R-0 n _�_0 Wall Wopd_ 69 X 071 R_19 R-�n_ 925 90 Wall MLOob_ 69 0 071 R-19 R_n n_ _315_-90 WaII yllM-d— 89 x-071 R_19 R -n 0_ 180 An Dnnr Nona 24 0 500 None R_0 0_ 180 _90 Wall Wnnd 59 _0.071 R_19 R -n 0 _0 9 Wall Wnnd 527 0071 R_19 R -n Q _ 270 _90 Wall Wnnd_ 106 n 071 R-19 R -n n _90 90 Rnnf Wnnd _ 1990 0 09R R-38 R_n n _ 0 Wall Wnnd 153 0071 R-19 --EL-0-0- 135 90 Wall Wood 59 _o 071 R_19 R_n n 225 90 Wall Wnod 52 _o 071 R_19 R-0 0 0 go Wall Wond 196 0071 R_19 R -nn 1RD go Wall Wnod 713 0071 R_19 R -a 0 270 90 Will Wnnd 180 0 071 R_19 R -n n --- qn gn Wall Wnnd 59 0.071 R_19 R -nom_ 315�Q Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: 7,216 ft2 n/a ft2 0 ft2 7,216 ft2 13.0 ft 1.00 Number of Stories: 1 1 # of Thermostat Vent Units Zone Type Type Hgt. Area _0 20_ Sleeping Sleep0ngc tal —2 n/a 018 Cnnditinned Seth;;rk —2 n/a 0.17 Conditioned Setback —2 n/a 0.24 Sleepung SleepingStat 2 n/a Gains Condition Y / N Status JA IV Reference Location / Comments nergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Paoe:3 of 24 1 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R MR A-MB.S-JAMFS WFYMOI1TH 7,216 ft2 1/28120 9 ._. Project Title 8081PORTOFINQ I A QI JINTA Raised Floor Area: 0 Date Project Address 7,216 ft2 Average Ceiling Height: Building Permit # Rl1_ I1 ECJ-JANICA1 SYSTFMS_JNC_ 1.00 (949) 453-1999 'Number of Stories: Documentation Author ' . Telephone Plan Check/Date Fnprmq PCD (-A CJin3ate 7nIlE15) 1 Field Check/Date Compliance Method Climate Zone TDV Standard Proposed Compliance •(kBtu/sf-yr) Design Design Margin Space Heating 2.24 2.11 0.13 Space Cooling 63.62 61.12 2.50 Fans 9.04 10.79 -1.74 Domestic Hot Water 3.56 3.56 0.00 Pumps 0.00 0.05 -0.05 Totals 78.45 77.62 0.84 Percent better than Standard: 1.1% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: [X—] Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (N) 0 deg Fuel Type: Natural Gas Fenestration: Area: 1,740 ft Avg. U: 0.47 Ratio: 24.1% Avg. SHGC: 0.40 - BUILDING ZONE INFORMATION Zone Name Total Conditioned Floor Area: 7,216 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 7,216 ft2 Average Ceiling Height: 13.0 ft Number of Dwelling Units: 1.00 'Number of Stories: 1 ' . # of Floor Area Volume Units Zone TvDe OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wood I Zns n n2A R -IR R -n n n n Wall Wood 104 n_n7l R_19 R -n 0 _n gn Wall Wood 238 n_n71 R_19 R -n n 18n gn Wall Wnnd 7..9n n 071 R-19 R -n n go gn Wall Wood 272 X71 R-19 R-0.0 925_ - Roof Wood 1 598 0.028 13_38 R-0 0 _ 0 Gains Condition Thermostat . Vent Type Hgt. Area GleepingStnt -2 n/a Y / N Status JA IV Reference Location / Comments El Naw-- 09 -AM 70NF3 ❑New 09-A23 70NF 2 ® ❑New 09-A23 70NF 2 ®❑New 09-A23 70NE 2 ®❑New 09-A23 ZONE 2 ® ❑New 02-A2R ZONE 2 12331 EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page:4 of 24 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R MR: &MRS. JAMESINEYMOIJTH --1/28/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments L Jndow Ernot /N) 9 0 0 290 NERD _0_a5 NERC 0 --q(Z New Fixed Glass rAr/RFnl/C CRR 2 Window Front (N) 12.3 0.370 NFRC 0_27 NFRC 0 90 New Casement Glass CAC/BED1/C0RR 3 Window Front (N) 12.3 0.370 NFRC 0_27 NFRC 0 90 New Casement Glass CAC/BED1/CORR 4 Window Front (N) 4.0 0.290 NFRC 0_35 NFRC 0 90 New Fixed Glass CAC/BED1/CORR '5 Window Front (N)_ 4.0 0.290 NFRC 0_35 NFRC 0 90 New Fixed Glass CAC/BED1/C0RR 6 Window Front (N_ 4.0 0.290 NFRC0 35 NFRC 0 90 New Fixed Glass CAC/BED1/CORR Z Window Front (N) 4.0 0.290 NFRC 0.35 NFRC 0 90 New Fixed Glass CAC/BED1/CORR 8 Window Right (W) 24.0 0.290 NFRC 0.35 NFRC 270 90 New Fixed Glass CAC/BED1/C0RR 6 Window Ri hcht (W) 19.2 0.370 NFRC 0.27 NFRC 270 90 New Casement Glass CAC/BED1/CORR _M Window Right (W) 19.2 0.370 NFRC 0_27 NFRC 270 90 New Casement Glass CAC/BED1/CORR 11 Window Right (W) 19.2 0.370 NFRC 0.27 NFRC 270 90 New Casement Glass CAC/BED1/C0RR 12 Window Right (W) 24.0 0.290 NFRC 0_35 NFRC 270 90 New Fixed Glass CAC/BED1/CORR 13. Window Right (W) 9.0 -DI90 NFR(J)35 NFRC 270 -,U New Fixed Glass CAC/BED1/CORR 14 Window Left (E) 33.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass CAC/BED1/CORR 15 Window Left (E) 4.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass CAC/BED1/CORR 16 Window Left (E) 4.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass CAC/BED1/CORR 17 Window Left (E) 30.2 0.290 NFRC 0_35 NFRC^ 90 90 New Fixed Glass CAC/BED1/CORR 18 Window Left (E) 24.0 0.290 NFRC 0_35 NFRC 90 90 New Fixed Glass CAC/BED1/CORR 1,Q Window Left (FE) 3.3 0.290 NFRC 0.35 NFRC 90 90 New Fixed Glass CAC/BED1/130RR 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. Window Overhang Left Fin Riqht Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 Ti Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen _ 0.76 16 Bug Screen 0.76 17 Bug Screen _ 0.76 18 Bug Screen _ 0.76 19 Bug Screen _ 0.76 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 1,470 4.00 28 0_98 0 26-A1 New CAC/BED1/C0RR / Slab on Grade Concrete, Heavyweight 1,290 4.00 28 0_98 0 26-A1 New ZONE5 / Slab on Grade Concrete, Heavyweight 1,220 4.00 28 0_98 0 26-A1 New ZONE4 / Slab on Grade Concrete, Heavyweight 1.708 4.00 28 0.98 0 26-A1 New ZONE3 / Slab on Grade Concrete, Heavyweight 1,528 4.00 28 0_98 0 26-A1 New ZONE 2 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 142 None No Insulation 26-A1 New CAC/BED1/CORR Slab Perimeter 50 None No Insulation 26-A1 New ZONE5 Slab Perimeter 80 None No Insulation 26-A1 New ZONE4 Slab Perimeter 149 None No Insulation 26-A1 New ZONE3 Slab Perimeter 119 None No Insulation 26-A1 New ZONE 2 Run Initiation Time: 01/28/09 13:23:08 Run Code: 1233177788 EnergyPro 4.4 by EnergySoft User Number. 2936 Job Number: Page:5 of 24 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R MR. .&_MRS-JAM ES -WEYMOUTH _. ___ __ -1/28/2009....._ .. _ Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 20. Windnw Laft (Fa 48.0 -0" NFRC -o 3? 21 Window Right (NW) 2.8 0.290 NFRC 0.35 22 Window Right (NW) 2.8 0.290 NFRC 0_35 23 Window Front (N) 60.0 0.290 NFRC 0.35 24 Window Front (N)_ 2.8 0.290 NFRC 0_35 25 Window Front (N) 11.2 0.370 NFRC 0_27 2E Window Front (N) 11.2 0.370 NFRC 0.27 27 _Window Front (N) 25.5 0.290 NFRC 0.35 2$ Window Front (N) 13.5 0.290 NFRC 0.35 2R Window Front (N) 13.5 0.290 NFRC 0.35 M Window Rear (S) 186.0 0.750 NFRC 0.59 31 Window Rear (S) 2.8 0.290 NFRC 0.35 M Window Rear (S) 7-8 -D-29D NFRC: _Q_35 33 Window Rear (S) 2.8 0.290 NFRC 0.35 34 Window Rear (S) 2.8 0.290 NFRC 0.35 35 Window Rear (S) 2.8 0.290 NFRC 0.35 36 Window Front (NE) 2.8 0.290 NFRC 0.35 37 Window Front (NE) 2.8 0.290 NFRC 0.35 ,U _Window Rear (,SW) 48.0 0.480 NFRC 0.32 NER('. C)Q qQ Npw Sliding (,lass (:A ./R D1/( 0RR NFRC 315 90 New Fixed Glass ZONE5 NFRC 315 90 New Fixed Glass ZONE5 NFRC 0 90 New Fixed Glass ZONE5 NFRC 0 90 New Fixed Glass ZONE5 NFRC 0 90 New Casement Glass ZONE5 NFRC -0 90 New Casement Glass ZONE5 NFRC 0 90 New Fixed Glass ZONE5 NFRC 0 90 New Fixed Glass ZONE5 NFRC 0 90 New Fixed Glass ZONE5 NFRC 180 90 New Pocket Sliders ZONE5 NFRC 180 90 New Fixed Glass ZONE5 NFRC; 180 qQ New Fixed Glass 70NE5 NFRC 180 90 New Fixed Glass ZONE5 NFRC 180 90 New Fixed Glass ZONE5 NFRC 180 90 New Fixed Glass ZONE5 NFRC; 45 90 New Fixed Glass ZONE5 NFRC 45 90 New Fixed Glass ZONE5 NFRC 225 90 New Sliding Glass ZONE4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhanq Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Buq Screen 0.76 _ 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen _ 0.76 29 Bug Screen _ 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen _ 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen _ 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 01/28/09 13.23.08 Run Code: 1233177788 EnergyPro 4.4 by EnergySoft User Number. 2936 Job Number: Page:6 of 24 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R MR. --&-MRS. JAMES -WEYMOUTH _ - ----_---..-_____-- .. _ -_ _ -.:1/28/2009 Project Title Date FENESTRATION SURFACES Insulation Condition Location/ Type Length R -Val. Location True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 33 _!Ins 0w_ Rlght_(NW 48 D. 0 48D NERC 0-32 NERC _31`9 __q9_ New Sliding rlacc ZONE4 40 Window Right (W)_ 16.5 0.290 NFRC 0_35 NFRC 270 90 New Fixed Glass ZONE4 41 Window Right (W) 16.5 0.290 NFRC 0_35 NFRC 270 90 New Fixed Glass ZONE4 42 Window Right (W) 24.0 0.290 NFRC 0.35 NFRC 270 90 New Fixed Glass ZONE4 43 Window Right (W) 3.3 0.290 NFRC 0_35 NFRC 270 90 New Fixed Glass ZONE4 44 Window Right (W)- 16.5 0.290 NFRC 0_35 NFRC 270 90 New Fixed Glass ZONE4 45 Window Right (W) 7.0 0.370 NFRC 0_27 NFRC 270 90 New Casement Glass ZONE4 46 Window Left (E) 24.0 0.290 NFRC 0.35 NFRC 90 90 New Fixed Glass ZONE4 A7 Window Left (SE) 30.0 0.750 NFRC 0-59 NFRC 135 90 New Pocket Sliders ZONE3 Aa Window Left (SE) 38.0 0.290 NFRC 0_35 NFRC 135 90 New Fixed Glass ZONE3 A9_ Window Left (SE) 32.0 0_290 NFRC 0_35 NFRC 135 90 New Fixed Glass ZONE3 50 Window Left (SE) 6.7 0.290 NFRC 0_35 NFRC 135 90 New Fixed Glass ZONE3 ,1 Window aear S_W 32,Q 029 NFRQ J)_35 FRC 225 __U New Fixed Glass 70NE3 52 Window Rear (SW) 6.7 0.290 NFRC 0_35 NFRC 225 90 New Fixed Glass ZONE3 53 Window Rear (S) 103.0 0.750 NFRC 0_59 NFRC 180 90 New Pocket Sliders ZONE3 54 Window Rear (S) 32.0 0.290 NFRC 0_35 NFRC 180 90 New Fixed Glass ZONE3 55 Window Rear (S) 6.7 0.290 NFRC 0_35 NFRC, 180 90 New Fixed Glass ZONE3 56 Window Right (W) 32.0 0.290 NFRC 0635 NFRC 270 90 New Fixed Glass ZONE3 JZ Window Right (W) 6.7 0.290 NFRC 0.35 NFRC 270 90 New Fixed Glass ZONES 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhanq Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. I -Ext. REA Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 01/28/09 13:23:08 Run Code: 1233177788 EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page: 7 of 24 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R MR --&-MRS. JAMES -WEYMOUTH- Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCz Azm. Tilt Stat. Glazing Type Comments ,9 Window Right (W) 250 _0_3D -HR(; -027 NFRC; 270 _gg_ New CacemPnt Glacc 70NF3 59 Window Right (W) 10.0 0.370 NFRC 0.27 NFRC 270 90 New Casement Glass ZONE3 60 Window Left (E) 180.0 0.750 NFRC 0_59 NFRC 90 90 New Pocket Sliders ZONE3 61 Window Right (NW) 32.0 0.290 NFRC 0_35 NFRC 315 90 New Fixed Glass ZONE3 •62 Window Right (NW) 6.7 0.290 NFRC 0_35 NFRC 315 90 New Fixed Glass ZONE3 63 Window Rear (S)_ 48.0 0.290 NFRC 0_35 NFRC 180 90 New Fixed Glass ZONE 2 64 Window Left (E) 40.0 0.480 NFRC 0.32 NFRC 90 _ 90 New Sliding_Glass ZONE 2 65 Window Left (E) 7.0 0.370 NFRC 0.27 NFRC 90 90 New Casement Glass ZONE 2 LE Window Left (E) 48.0 0.480 NFRC JLU NFRC 90 90 New Sliding Glass ZONE 2 LZ _Window Left (E) 48.0 0.480 NFRC 0.32 NFRC 90 90 New Sliding Glass ZONE 2 _$ Window Left (E)_ 10.5 0_370 NFRC 0_27 NFRC 90 90 New Casement Glass ZONE 2 69 Window Left (E) 7.0 0.370 NFRC 0.27 NFRC 90 90 New Casement Glass ZONE 2 M Window Rear (SW) 80.0 0.480 NFRC J1,32 NFRC _225_ -9D- New Skiing Glass ZONE 2 71 Window Rear (SW) 2.8 0.290 NFRC 0_35 NFRC 225 90 New Fixed Glass ZONE 2 72 Window Rear (SW) 2.8 0.290 NFRC 0_35 NFRC 225 90 New Fixed Glass ZONE 2 73 Window Rear (SW) 2.8 0.290 NFRC 0_35 NFRC 225 90 New Fixed Glass ZONE 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen 0.76 66 Buq Screen 0.76 67 Bug Screen 0.76 68 Bug Screen0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 71 Bug Screen _ 0.76 72 Bug Screen 0.76 73 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Len Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 01/28/09 13:23:08 Run Code: 1233177788 EnergyPro 4.4 by EnergySoft User Number. 2936 Job Number. Page:8 of 24 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R MR. &MRS. JAMES WEYMOUTH - - Energy - ..-1/28/2009 Project Title Location Heating Cooling Date R -Value Status Tested? HVAC SYSTEMS Ducted Ducted Attic 4.2 New No GREAT RM./ DINING/FOYE Ducted Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type CASITAS/BED/COR Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback GREAT RM./ DINING/FOYE Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback BED2 / OFFICE Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? CASITAS/BED/COR Ducted Ducted Attic 4.2 New No GREAT RM./ DINING/FOYE Ducted Ducted Attic 4.2 New No BED2 / OFFICE Ducted Ducted Attic 4.2 New No Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A.O.Smith FSG -100 Small Gas Recirc/Demand 1 75,000 100 New 0.60 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS CONTRACTOR IS PROVIDING AND SIZING THE A/C SYSTEM SEE MECHANICAL DRAWINGS FOR SIZES AND ZONES.A/C SEER TO BE MIN. 14, FURNACE AFUE MIN. 80%. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: A + A GROUP ARCHITECTS Address: 20341 SW BIRCH ST. # 320 NEWPORT BEACH CA 92660 Telephone: 949-N5019O9t Lic. #: 't (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) 4.4 Documentation Author Name: OMID TOHIDIAN Title/Firm: BUILDING MECHANICAL SYSTEMS, INC. Address: 410 GODDARD Telephone: Go T W No tri, 0 HA OF r AL1F (date) Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R -MR.-&-MRS.- JAMES' -WEYMOUTH Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type DEN/MORN/KITCHEN Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback MSTR/GYM Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Location Duct Coolina Location DEN/MORN/KITCHEN Ducted Ducted Attic MSTR/GYM Ducted Ducted Attic Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 New No 4.2 New No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS -ONTRACTOR IS PROVIDING AND SIZING THE A/C SYSTEM SEE MECHANICAL DRAWINGS FOR SIZES AND ZONES.A/C SEER TO BE MIN. 14, =URNACE AFUE MIN. 80%. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: OMID TOHIDIAN Title/Firm: A+ A GROUP ARCHITECTS Title/Firm: BUILDING MECHANICAL SYSTEMS, INC. Address: 20341 SW BIRCH ST. # 320 Address: 410 GODDARD NEWPORT BEACH, CA 92660 IRVINE, CA 92618 Telephone: 949-250-1909 Lic. #: Telephone: (949) 453-1999 (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) (signature) (signature) (date) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R MR. &'MRS. JAMES -WEYMOUTH - 1128/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "CASITAS/BED/COR" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design - Verify Thermal Mass: 1470 sqft Exposed Slab Floor, 4.00" thick at cas.& bdrm.1/ baths/ corr. HIGH MASS Design - Verify Thermal Mass: 1290 sqft Exposed Slab Floor, 4.00" thick at grtrm./dinng./foyr./pwdr. HIGH MASS Design - Verify Thermal Mass: 1220 sqft Exposed Slab Floor, 4.00" thick at bed rm. 2/bath2 &3/office/corr. The HVAC System "DEN/MORN/KITCHEN" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design - Verify Thermal Mass: 1708 sqft Exposed Slab Floor, 4.00" thick at den/mrngrm./kit./bar/pnt./pw. The HVAC System "MSTR/GYM" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design - Verify Thermal Mass: 1528 sqft Exposed Slab Floor, 4.00" thick at Master Suite & Gym HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "CASITAS/BED/COR" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "3.5 TON HVAC SYSTEM " includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "GREAT RM./ DINING/FOYE" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "5 TON HVAC SYSTEM" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "BED2 / OFFICE" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "3.5 TON HVAC SYSTEM " includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "DEN/MORN/KITCHEN" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "5 TON HVAC SYSTEM" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "MSTR/GYM" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "5 TON HVAC SYSTEM" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. I EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page: 11 of 24 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE= Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements,from'the Certificate of Compliance supercede the-itemsmarked•with an asterisk (')-below. -When this checklist is incorporated -into the -permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether thev are shown elsewhere in the documents or on this checklist only. Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - DESCRIPTION permit application documentation. N/A DESIGNER MENT Building Envelope Measures w§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ ❑ apply to exterior mass walls). ❑ ❑ ❑ •§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ 0 ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑x ❑ b. outside airintake with damper and control, flue damper and control Elf ❑X El 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory iri Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor , ❑ ❑ ❑ permeance rate no greater than 2.0 permfinch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ 'CF -6R Form: ❑ 0 ❑ § 1.16-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ Q ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank -insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page: 12 of 24 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the -Certificate of-Compliance*supercede the items marked with an asterisk (')-below- When-this-checklistis-incorporated into -the -permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is,used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) �010_1 ❑ ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ® ❑ § 118 (i): Cool Roof material meets specified criteria - ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ FX ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft_ User Number: 2936 Job Number. Page: 13 of 24 Residential Kitchen Lighting Worksheet WS -5R .1/28/2009__._ _. _ ..-...._ Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity' Watts Other Watts 50w Low Voltage Halogen Yes X No 55.0 x_ 8 = 440 or (2) 18w Fluorescent Downlights Yes X I No 1 42.0 x 10 = 420 or 14w Linear Fluorescent T5 Elec Yes X1 No 1 18.0 x 10 = 180 or Yes No x = or Yes No x = or Yes No x' = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 1,040 B: 0 COMPLIES IF A;-> B YES ® NO ❑ EnergyPro 4.4 by Energysoft User Number. 2936 Job Number: Page: 14 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME -DATE MR. &MRS. JAMES 1NEYMOUTH __ - 1/28720.09- SYSTEM NAME FLOOR AREA CASITAS/BED/COR 1,470 Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sgft) 23.8 Cooling System Output per System 36,000 Total Output (Btuh) 36,000 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 24.5 Total Output (sgft/Ton) 490.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 0.54 Airflow (cfmrron) 266.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 82 22,331 -62 551 20,486 48.0 46.1 of 0 O s 3,972 2,628 0 0 0 0 0 0 0 0 Supply Fan Cooling Coil 0 31972 1 2,628 30,276 -62 25,743 HVAC EQUIPMENT SELECTION 3.5 TON HVAC SYSTEM 29,698 0 35,000 Total Adjusted System Output 29 698 0 35,000 (Adjusted for Peak Design Condition's) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am AEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 of 66.9 of 66.9 of 107.7 of 10 :F5 Supply Air Ducts lo - Outside Air rri: 0 cfm 104.7 of Supply Fan Heating Coil 800 cfm ROOMS 70.0 of 66.9 OF I Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0172.4 of 82.6 60.2 of 82.6 ' 60.0 of - 48.0 46.1 of O s Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 52.6 48.2 of 800 cfm ROOMS 29.7% R.H. 78.0/58 OF 82.6/60.2 0 .5 Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page:15 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME..... -MR: &-MRS. JAMES WEYMOUTH ..... _-1728/2009_ ._ . SYSTEM NAME FLOOR AREA GREAT RM./ DINING/FOYE 1,290 EATING SYSTEM PSYCH 26.0 of 69.0 of Outside Air 0 cfm Supply Fan 2000 cfm 69.0 of 69.0 of SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,162 23,582 43 519 17,042 0 4,195 2,187 0 0 0 0 0 0 0 0 0 4,195 2,187 31,97 43 21,415 5 TON HVAC SYSTEM 48,987 2,486 70,000 Total Adjusted System Output 48,987 .2,486 70,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am -eam Temperatures at Time of Heating Peak) 101.6 of Supply Air Ducts Heating Coil 100.6 of ROOMS 70.0 of K Return Air Ducts `4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 72.4 of 80.0 / 62.6 of 80.0 62.5 °F 57.1 / 54.2 of ".r•4 Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 59.1 / 55.0 of 2000 cfm 40.2% R.H. ROOMS 80.0/62.6 of 78.0: 62.0 of Return Air Ducts I . L EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page: 16 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME - DATE _ ___.___.MR:..& MRS. JAMES -WEYMOUTH _...._ --1/28/2009 SYSTEM NAME FLOOR AREA BED2 / OFFICE 1,220 SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 624 17,995 84 446 17,070 EATING SYSTEM PSYCHROMETRICS 0 Peak 26.0 OF 3,201 2,190 0 0 0 0 0 0 0 0 0 3,201 2,190 24,396 84 F 21,451 HVAC EQUIPMENT SELECTION 3.5 TON HVAC SYSTEM 29,480 0 35,000 Total Adjusted System Output 28,480 0 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 67.4 OF 67.4 OF 108.3 OF :40 Supply Air Ducts Outside Air 0 cfm 105.7 °F Supply Fan Heating 800 cfm Coil ROOMS 70.0 OF 67.4 OF 111.0.! 72.4 OF Outside Air 0 cfm 81.7: 59.7 °F EnergyPro 4.4 �% Return Air Ducts `+ ROMETRICS (Airstream Temperatures at Time of Cooling Peak 81.7 % 59.7 OF 81 7 / 59.5 OF "v 47 4 145 5 of Supply Fan 800 cfm User Number: 2936 Cooling Coil Return Air Ducts F' Job Number: Supply Air Ducts 51.1 / 47.2 OF 29.2% R.H. ROOMS 78.0158.3 OF I 17 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME . DATE .. __ - _.-----MR. ----MR.--&-MRS-.'JAMES WEYMOUTH _. - - . __ _.. _ _ _ - - 1%2872009 SYSTEM NAME FLOOR AREA DEN/MORN/KITCHEN 1,708 GINEERI Number of Systems 1 Heating System Output per System 70,000 Total Output (Btuh) 70,000 Output (Btuh/sqft) 41.0 Cooling System Output per System 60,000 Total Output (Btuh) 60,000 Total Output (Tons) 5.0 Total Output (Btuh/sqft) 35.1 Total Output (sgftrron) 341.6 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.17 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 )te: values above given at ARI conditions :ATING SYSTEM PSYCHROME 26.0 of 68.2 of c' Outside AirO ,r t.; 0 cfm Supply Fan 2000 cfm 68.2 OF SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM iSensiblel Latent I CFM I Sensible 2,048 38,057 -202 984 30,569 0 6,769 3,922 0 0 0 0 0 0 0 0 0 6,7691 3,922 51,595 202 38 413 HVAC EQUIPMENT SELECTION 5 TON HVAC SYSTEM 50,695 1,037 70,000 Total Adjusted System Output 50,695 1,037 70,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm . Jan 12 am ream Temperatures at Time of Heatina Peak) 68.2 of 100.8 of Heating Coil 11 Return Air Ducts 4 Supply Air Ducts 99.0 OF ROOMS 70.0 OF DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 72.4 of 81.2 162.9 of 81.2 , 62.8 °F 57.5/54.30f Supply Air Ducts Outside Air Is 0 cfm Supply Fan Cooling Coil 60.7 155.6 OF 2000 cfm 39.9% R.H. ROOMS 81.2! 62.9 of 78.0 161.9 of Return Air Ducts < I EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. _ Page: 18 of 24 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAMEDATE __. -1/28/2009 SYSTEM NAME FLOOR AREA MSTR/GYM 1,528 (STEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM FSensible 1,464 28,827 96 633 20,482 0 5,128 2,628 0 0 0 0 0 0 0 0 0 5,128 2,628 39,083 -96 25 738 HVAC EQUIPMENT SELECTION 5 TON HVAC SYSTEM 49,636 1,918 70,000 .Total Adjusted System Output qg s36 1,918 70,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm C Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 68.8 OF 68.8 OF 17 101.4 OF Outside Air Supply Air Ducts QV 0 cfm 100.2 OF Supply Fan Heating Coil 2000 cfm ROOMS 68.8 OF 70.0 °F DOLING SYSTEM PSYCHROMETRICS Airstream 1 111.0 172.4 OF 80.4 / 62.7 OF 80.4 / 62.6 OF b 64 Outside Air 1, 0 cfm 80.4/62.7 °F JnergyPro 4.4 Return Air Ducts `4 watures at Time of Coolin 57.2/54.3°F Supply Fan Cooling Coil 2000 cfm User Number: 2936 h Return Air Ducts '4 Job Number. Supply Air Ducts 59.6155.2 OF 40.0% R.H. ROOMS 78.0; 61.9 OF 19 of 24 ROOM LOAD SUMMARY PROJECT NAME ---MR*. -& MRS. JAMES DATE _._1728/2009 ----17Z8/2009-' SYSTEM NAME CASITAS/BED/COR FLOOR AREA 1,470 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE CAC/BED1/CORR cas.& bdrm.1/ baths/ corr. 1 821 22,331 -62 821 22,331 -62 551 20,486 PAGE TOTAL r 821 F22,3311 -62 551 20,486 TOTAL 1 821 22,331 -62 551 20,486 EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number. Page: 20 of 24 ROOM LOAD SUMMARY PROJECT NAME -_-- MR7&-MRS: JAMES__WEYMOUTH DATE --- -1128/20-0-9 SYSTEM NAME GREAT RM./ DINING/FOYE FLOOR AREA 1,290 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE5 g rtrm./d in ng./foyr./pwd r. 1 1,162 23,582 43 1,162 23,582 43 519 17,042 PAGE TOTAL 1 1,162 23,582 43 519 17,042 TOTAL 1 1,162 23,582 43 519 17,042 EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page: 21 of 24 ROOM LOAD SUMMARY PROJECT NAME _ _ . MR. &-MRS: JAMES -WEYMOUTH _ DATE --'1728/2099 SYSTEM NAME BED2 / OFFICE FLOOR AREA 1,220 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT. CFM SENSIBLE LATENT CFM SENSIBLE ZONE4 bedrm.2/bath2&3/office/corr. 1 624 17,995 84 624 17,995 84 446 17,070 PAGE TOTAL 1 624 17,9951 84 446 17,070 TOTAL 1 624 17,995 84 446 17,070 EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page: 22 of 24 ROOM LOAD SUMMARY PROJECT NAMEDATE MRS -JAMES -WEYMOUTH--- _.._........ __ _ .._ _.._. _ __... ....._._-_.1/28%2009_.. - - --- �MR. & . SYSTEM NAME DEN/MORN/KITCHEN FLOOR AREA 1,708 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE3 den/m rng rm./kit./bar/pnt./pw. 1 2,048 38,057 -202 2,048 38,057 -202 984 30,569 PAGE TOTAL 2,048 38,057 -202 1984 30,569 TOTAL 1 2,048 38,057 -202 984 30,569 EnergyPro 4.4 by EnergySoft User Number. 2936. Job Number Page:23 of 24 ROOM LOAD SUMMARY PROJECT NAME -- - -- MR: &'MRS:_JAMES-WEYMOUTH-. _ DATE - -112872009 SYSTEM NAME MSTR/GYM FLOOR AREA 1,528 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 2 Master Suite &Gym 1 1,464 28,827 -96 1,464 28,827 -96 633 20,482 PAGE TOTAL 1,464 28,827 -96 633 20,482 TOTAL 1 1,464 28,827 -96 633 20,482 EnergyPro 4.4 by EnergySoft User Number: 2936 Job Number: Page:24of 24