Loading...
12-0357 (AR),< P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: f#1l2000:0�0 5_j7 Property Address: 80715 VIA PORTOFINO APN: 777-150-017- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 35000 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: RICHEY 80715 VIA PORTOFINO LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/27/12 Contractor: Applicant: Architect or Engineer: ANTHONY & ASSOCIATES, JOHN 80591 TANGELO COURT F� INDIO, CA 92201 2U12 (760) 578-6441 Lic. No.: 845082 `iTyOFLAQUINTA ?rMk NCF r)FpT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B i nse No.: 845082 Date: 1�actor: OWNER -BUILDER ECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500): (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.l. (_) I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier E7 9MPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Codel s hwit comply it those provisions. r D Applicant: WAR ING: AILURE TO SECURE WO KERS' COMPENSATION COVER GE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county drdinances and state laws relating to building con ruction, and hereby authorize representatives of this cou ty tGo a/nee2r upon the above-mentioned property f i n purposes Date����tllgnature (Applicant or Agentl: Application Number . . . . . 12-00000357 ------ Structure Information (2) 68SF PATIO ENCLOSURES ----- Other struct info . . . . . CODE EDITION .2010 FLOOD ZONE NO IST FLOOR SQUARE FOOTAGE ------------------------------------------------------ ----------------------- 136.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 317.00 Plan Check Fee 206.05 Issue Date . . . . Valuation . . . . 35000 Expiration Date . . 6/25/13 Qty Unit Chargc rcr L'wL�il3iuli BASE FEE 252.00 10.00 6.5000 THOU BLDG 25,001-50,000 ---------------------------------------------------------------------------- 65.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 19.76 Plan Check Fee 4.94 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/25/13 Qty Unit Charge Per Extension BASE FEE 15.00 136.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY ----------------------------------------- ---------------------------------- 4.76 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/25/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 ---------------------------------------------------------------------------- Special Notes and Comments TWO (2) 68SF PATIO ENCLOSURES - WINE ROOM AND OFFICE ADDITION/VB/RES-3/CLASS A -FR [ENGINEERED] OFFICE NOT PERMITTED FOR SLEEPING PURPOSES. THIS PERMIT DOES NOT INCLUDE ANY OTHER REMODEL WORK TO THE EXISTING DWELLING. 2010 CALIFORNIA BUILDING CODES. December 27, 2012 4:56:07 PM AORTEGA LQPERMIT Application Number . . . . . 12-00000357 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 20.61 STRONG MOTION (SMI) - RES 3.50 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 356.26 ------------------------------ .00 .00 356.26 Plan Check Total 215.87 .00 .00 215.87 Other Fee Total 26.11 .00 .00 26.11 Grand Total 598.24 .00 .00 598.24 LQPERMIT Bin. # ! ... `. ... 01 O" LA Quth :. Bui0hy 8i Safety Division P.O. Box 1504, 78-4.95 Calle Tampico La.Quinta, G 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheen Perintt # G%� Project Address: �Q— 7/� Ol `j�a Owner's Name:./G A. P. Number. Address: 0 t, t'l Legal Descriptionlj i, r4 t? .�54-N L Contractor. 6O OG TC City, ST, Zip: - Telephone: Address: _ 5 r C�- Project Description: (kb — VC . ` ! City, ST, Zip: Ai,Q ` • e ajar, v�4�r .ext ..i'�' ,, h, , : ?'State Lic. # :s M Telephone: f.!Lic. Arch., Engr., Designer. Address: l City., ST, Zip:/q Oj Telephone: lob S16 !00 $ v Y. ` State Lic. #: r% m:.« Name of Contact Person: &0' Construction Type: (( Occupancy: .1.Z." . Project type (circle one): New Add'n Alter Repair Demo Sq. Ft : A97 #Stories: # Units:, Telephone # of Contact Person:7/,C) - Estimated Value of Project:� APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd . TRACKNG PERMITFEES Plan Sets 3 Plan Check submitted y/3 it. Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit, . 'Fuss Cates. Called Contact Person Plan Check Balance Title 24 Calcs. a Plans picked up �I96.3 Flood plain ptau Pians resubmitted.. 11i�Canstructlon Mechanical Grading plan 211 Review, ready forecti rsstre Electrical Subcontactor IAst Called Contact Person ��' Plumbing Grant Deed Pians picked up S.N.L H.O.A. Approval Plans resubmitted Grading Aft IN HOUSE:- '^` Review, ready for correctio ae Developer Impact Fee Planning Approval.-'00'tCalled Contact Person �yA.I.P.P. • . Pub. Wks. Appr Date of permit Issue • School Fees Y Total Permit Fees %.'L 101.o1 ... ICK l2A5 iZ o u st �OM� 'Ce STi4,rwA *FK . ' . Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOU=JT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Mack Richie Date: December 13, 2012 Owner's Name: Mack Richie Phone No. (760) 578-6441 Project Address: 80-715 Via Portofino, La Quinta, CA 92253 Project Description: Residential Addition APN: 777-150-017 Tract #: Lot #'s.- Type 's:Type of Development: Residential XXi Commercial Industrial Total Square Feet of Building Area: 137 Certification of Applicant/Owners: The person signing certifies that the above information is zorrect and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/`9eveloper. Dated: 12/13/12 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN :)R WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 137 Pursuant to AB 181 any room additions or enclosures of 500 Amount per Sq.Ft. $3.20 s.f. or less are exempt from developer fees. Any mobile homes being relocated within the same school districts jurisdiction Amount Collected EXEMPT are exempt from developE.r fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst NOTICE OF 90 DAY PERIOD FOR PROTEST OF F-EgAND STA NT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 9C -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payanent of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days slarts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/dcvfees/ecilificate of compliance form updated 3-2007 11/2010 • ofd CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE &A 1 106 BY RICKEY RESIDENCE FOOTING REVISION 80-715 VIA PORTOFINO LA QUI NTA/ CA. 92253 l2.eWl PLYV'{OOD 5-IEAR 2xb OR 2x4 STUDS AT ) 2x PT SILL PLATE w/5/9"mx14" A.B. Ib" O/G ` WINDOW j rf 0 AT 45' O/G MAX MIN. 2 PER PLATE 4 -TO b" WIDE GONGRETE CURB J AS PER ARGHITEGTURALS 4 TO b" WIDE wl3"x3"xl/4" PLATE WASHERS E.N. -^^ "" 4" GONGRETE SInB L w/tf3 AT 13" O/C EA. D WAY CENTER CF _.LAB �- Q GONGRETE CURB 4" GONGRETE SLAB w/p3 AT 18' OAS EA. 2f1 5 BAR m TURN DOWN 9" INTO If F FOOTING m WAY CENTER OF SLAB TURN DOWN q° INTO CONT. _z C H FOOTING F.GJHARD5GAFE CO05 NT. 9 F.GJHARDSCAPE 2' SAND 0'•/E40'•/E410 MIL VAPOR BARRIER i \ 2° SAND OVER 10 MIL ) /� VAPOR BARRIER D5 BAR CONT. TOP �.` AND BOTTOM S S� tt5 BAR GONT. TOP AND BOTTOM 4 FOUNDATION DETAIL AS NOTED 5 FOUNDATION DETAIL AS NOTED ' f CITY- OF LA QUINTA' SUB-CONTRACTOR LIST JOB ADDRESS �� '"� 15- `r�'�� T�F1AJO PERMIT NUMBER OWNER 12-(4-1+ 1 -1;-;, BUILDER344 'L-oru SSG• This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous Dlace. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. Trade / Classification Cont rector, :: :;; Workers,Com erlsatw�:ansurance:°' <`.' ':.. • ::::.. > : <.::.:::.:.:.:.: :.State::Contractor .s License... City. Business License>:. Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date Carrier Name (xx/xx/xx) (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C-12).1-d CONCRETE (C-8) ' .�� C.D O '�W `�C`7U�L t) I�W�D3 8 FRAMING .1G-51 .:: .,jD�M A%+tV /� � �9/ o r5 2 / Cid l 17 S STRUCT.:STEEL (C-51) ---- MASONRY (C-29) PLUMBING (C-.36) ' LATH; PLASTER (C=35) DRYWALL (C-9) . ..: a do G— q5 j 241 1 3 r % 3 1 r ZEN 1'r 5. �e HVAC. (C-201'::: fs. /T 1 '� -Z-06 Zai 1 't IP u r r 1 b 3 4 6 ELECTRICAL. (C=101 .. ,. , 1 C-10 X611014 3 3r A-(AA4-". T,N5 R �►� 5- 6 1 r a FLOOiRING (C'�:151:. GLAZING (C-17).. INSI11 ATInN (C,?) C-42) SEWAGE DISP (d-42)- PAINTING PAINTING IC=33) CERAMIC TILE (C-54) CABINETS (C-6) FENCING (C-13) LANDSCAPING (C=27).-??:. POOL (C-53) Prescri • tive Certificate of Compliance: CF -1 R ADD Residential Additions Pae 1 of 5 Site Address: 80-715 VIA PORTOFINO Enforcement Agen -y: CITY OF LA QUINTA Date: 12/27/2012 Standard Values From JA4 Table Tag/ ID' General Information Project Name MACK RICHE - WINE AND OFFICE ADDITIONS Climate Zone # 15 # of Stories 1 Building TypeO Single Family El Multi Family _T Circle the Front Orientation: Tv, E, S, W or Degrees N/E Conditioned Floor Area of Addition (CFA): 4,423 New Addition Size: Less than or equal to 100 ftZ x Less than or equal to 1000 ftZ (Do not use this orm or additions greater than 1000A NOTE: For Alterations to an existing home, submit a completed CF -IR -ALT Form. Exception: Existing HVAC systems that are replaced or altered to serve lite addition may be included on the CF -IR -ADD Form. PRESCRIPTIVE ENVELOPE REQUIREMENTS FOR ADDITIONS For standard wood and assemblies meeting the Cavity R -value only. • For /00 ftZ additions; the Proposed values must be equal or greater than the Standard column or w4en indicated when using Package D, "Pkg D ". Enter values in the shaded Proposed Columns. • For less than 1,000 ftZ additions must comply with "Pkg D" requirements unless indicated in the Standard Column. To meet "Pkg D" minimum -energy compliance re uirements, see RCM Appendix B, Table 151-C or §152(b) in the RCM. Enter values in the shaded Proposed Columns. Size of Addition 100 ftZ or less Less than 1,000 ftZ Component Standard Proposed Comment Standard Proposed Comment Ceiling insulation R-19 Minimum Pkg D R-38 Table 151-C Wall Insulation R-13 Minimum R-13 R-21 Minimum Floor Insulation R-13 Minimum Pkg D N/A Table 151-C Fenestration U- U- factor SHGC factor SHGC 0.40 Pkg D Enter Values From "Fenestrationt 50 ftZ > ftZ Proposed — Areas" Page 2 of 5 U- factor SHGC U- factor SHGC Enter Values From "Fenestration Proposed Areas" Page 2 of 5 0.40 Pkg D ,40 ^- .35 Maximum GlazingAddition Area Alooe 123.5 ft 2 Enter Values From "Addition Allowed Fenestration Areas" Page 3 of5 For West-FacingN!A Orientation 1,3 ft z Radiant Barrier N/A Pkg D Table 151-C Roofing N/A See Roofing Products Below Pkg D See Roofing Products Below OPAQUE SURFACE DETAILS For the furred portioned of Mass Walls see Furring Strips Construction Table below. A B C D E F G I H I J Proposed bee ote Standard Values From JA4 Table Tag/ ID' Assembly Name or Type 2 Framing Thickness, Material Spacing, and Size or Other U- factor Framed Continuous JA4 Proposed JA4 Table Cavity Insulation Assembly Assembly Numbers R -value` R -Value? Cell Value U-factor9 ALL WALLS WOOD 2X6@16" 0.102 4.3 21 0 A-6 .069 Note: For fturred assemblies, accounting for Continuous Insulation R -value, see Page JA4-3 and Equation 4-1. For calculating furred walls use the Mass and Furring Construction table below. Registration Number: 2008 Residential Compliance Forms Registration Date/Time: HERS Provider: March 2010 Prescriptive Certificate of Compliance: CF -1 R ADD Residential Additions (Page 2 of 5 Site Address: Enforcement Agency: Date: 80-715 VIA PORTOFINO CITY OF LA QUINTA 12/27/2012 Walls From Reference 1. For Tag/11) indicate the identification name that matches the building plans. 2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc... Indicate in column G the Frame material and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies. 3. Enter the thickness for mass in inches or Spacing between framing members enter; 16 "or 24 "OC; or Other for all other assembly description such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel, and etc.... 4. Based on the Climate Zone; enter the equivalent U factor found in J44 Table based on the R -Value from Table 151-C 5. Enter the Table number that closely resembles the proposed assembly. 6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0". 7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter "0 ". 8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J. 9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply. FURRING STRIPS CONSTRUCTION TABLE FOR MASS WALLS ONLY A I B I C I D I E F G I H I 1 I J I K L M Proposed Properties of Masonry and Concrete Added Interior or Exterior Insulation Walls From Reference in Furring Space from Reference Joint Appendix Table 4.3.5, 4.3.6, 4.3.7 Joint Appendix Table 4.3.13 a; Assembly j U T ° `o •° = o Ucu"� c10 > . 3 N Final N Mass Name or JA4 Table ' H O .� �p N N •p = L 7 — E E Assembly 2 > Type Number > rb''Thickness' Comment 1. Indicate the Mass Thickness from Reference Joint Appendix JA. 2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc... Indicate the Frame type and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies. 3. Enter the Table number that closely resembles the proposed assembly. 4. Enter the row and column of the U factor value. 5. Enter the Effective R -value listed in the JA4 Table Number. 6. The Final Assembly is calculated by using Equation 4-1 or Equation 4-4 of the Reference Joint Appendix J44. Enter the value in Column L. 7. Insert the Final Assembly U- actor value back on to the Opaque Surface Details table in Column J. FENESTRATION PROPOSED AREAS Orientation Fenestration Type and Frame (North, East, ProposedAreal Maximum Maximum NFRC or (Window, Glass Door or Skylight). South, West) ftZ) Ll -factor"' SHGCZ' 3' ° Default Values5 WINDOW N/E 72 .40 .35 NFRC Total 1. Fenestration area is the area of total glazed product (i.e. glass plus frame). Exception: When a door is less than 50% glass, the fenestration area may be the glass area plus a 'T inch frame" around the glass. 2. Enter value from Component Package D Requirements in Table 151-C. 3. Actual fenestration products installed and as indicated in CF -6R -ENV Form shall be equivalent to or have a lower U factor and/or a lower SHGC value than that specified on the Fenestration Proposed Area table above. 4. Submit a completed WS -3R Form if a reduced SHGC is calculated with exterior shading. 5. Ifopplicable at this stage enter "NFRC" or NFRC Certified windows or CEC "Default " valuesfound in Table 116-A or B. Registration Number: 2008 Residential Compliance Forms Registration Date/Time: HERS Provider: March 2010 Prescriptive Certificate of Compliance: CF -1R ADD Residential Additions (Page 3 of 5 Site Address: Enforcement Agency: Date: 80-715 VIA PORTOFINO CITY OF LA QUINTA 12/27/2012 ADDITION ALLOWED FENESTRATION AREAS Check applicable box below if the roof addition is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the boxes are A B C D E Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the above Cool Roof criteria F Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, check CFA of Addition Allowed % Allowed Area Area Removed 2 Maximum Allowed Area Proposed Areas Thermal ft2 of CFA (A x B) ft2 (C + D) Reflectance;'4 (Table Above) Total Fenestration Area 137 0.20 27.5 96 123.5 > 72 West Fenestration Area 0.05 0 > N/A (Required In CZ's 2, 4 & 7 -15 0a — 1. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1::2. 2. Glass removed to make wayfor the addition. 3. For additions less than 1,000f? the standards allows glazing removed during the remodel to be added to the glazing area allowance. The maximum allowed glazing area for the addition is the CFA x 20% + glass removed to make way far the addition. 4. In climate zones 2, 4, 7-15, no more than 5% of the CFA is allowed for west facing glazing plus west facing glass area removed to make way for the addition. The maximum allowed west facing glazing area is the CFA x 5% + west facing glass removed to make way for the addition. 5. To meet compliance, the Proposed Area must be less than orequal to the Total Allowed Area or EOTH the Total and West Fenestration Areas. ROOFING PRODUCTS (COOL ROOFS) §151(1)12 Check applicable box below if the roof addition is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the boxes are checked below, the Aged Solar Reflectance and Thermal Emittance requirements for roofing product; in §118(1) are not applicable. Do not fill table below. _ Roofing. compliance Not Required in Climate Zones 1-12, 14, and 16 with a Low -Sloped. Less or2:12 pitch. E] Roofing compliance Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped. Rocfs pitch greater than 2:12 and product weight less than 5lb/ft2. Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the above Cool Roof criteria F1 Roof constructions that have thermal mass over the roof membrane with at least 25 Ib/ft2 is exempt from the above Cool Roof criteria. Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, check he applicable box below if Exempt from the Roofing Products "Cool Roor' Requirement: Roof Slope Product Weight Product Aged Solar Thermal CRRC Product.ID Number < 2:12 > 2:12 < 5lb/ft2 >— 5lb/ft2 Type 2 Reflectance;'4 Emittance SRI 0 0 13 �a 0 0 ® 0a a 0 0 D pa 0 0 ® �a 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Produci Directory at www. coolroofs. omlproducts/search. php. 2. Indicate the type of product is being used for the rooftop, i.e. single ply roof, asphalt roof, metal r&9f, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory.then.use the Initial Reflectance value from the same directory and use the equation (0.2+0.7(p;,,;,jQj — 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance. 4. Check box if the Aged Reflectance is a calculated value using the equation above. 5. Calculate the SRI value by using the SRI- Worksheet at http://www.enerev.ca.Qov/title24/and enterthe resulting value in the SRI Column above and attach atopy of the SRI- Worksheet to the CF -I R. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface wid meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)4. Select the applicable coating: El Aluminum -Pigmented Asphalt Roof Coating 0 Cement -Based Roof Coating 0 Other Registration Number: Registration Date/Time: HERS Provider: 2008 Residential Compliance Forms March 2010 Prescriptive Certificate of Compliance: CF -111 ADD Residential Additions (Page 4 of 5 Site Address: 80-715 VIA PORTOFINO Enforcement Agency: Date: 12/27/2012 CITY OF LA QUINTA HVAC SYSTEMS - HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydropic space heating. Individual dwelling DHW heaters must be storage gas or propane fired, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage Configuration Duct or Configuration (Central, Split, Space, Package or H dronic Minimum Distribution Piping (Central, Split, Heating Equipment Efficiency Type and Insulation Thermostat Space, Package or —Type and Capacity 1.2, 3 AFUE or HSPF) Location' R -Value Type H dronic EXISTING Energy Factor or Thermal Efficiency Insulation R-Value3 EXISTING 1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc.) 2. Electric resistance heating is allowed only in Component Package C, or except where electric heating is supplemental (i.e., if total capacity < 2 KW or 7,000 Btu/hr electric heating is controlled by a time -limiting device not exceeding 30 minutes). See ,¢151(6)3 exception. 3. Refer to the HERS Verification section on Pages 3 and 4 of the CF -IR -ADD Form for additional requirements and check applicable boxes. 4. Indicate Type or Location (Ducts, H dronic in Floor, Radiators, etc. HVAC SYSTEMS - COOLING List water heaters and boilers for both domestic hot water (DHW) heaters and hydropic space heating. Individual dwelling DHW heaters must be storage gas or propane fired, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage Configuration Cooling Equipment Minimum Distribution Duct or Piping Type and Capacity 1.2 Efficiency Type and Insulation Thermostat (SEER/EER or COP) Location R -Value Type. (Central, Split, Space, Package or H dronic EXISTING Raised Slab Insulation r] YES [E NO 1. Indicate Cooling Type (A/C, Heat pump, Evap. Cooling, etc). Water Heater Type/Fuel Type' 2. Refer to the HERS Verification section on Pages 3 and 4 of the CF- IR -ADD Form for additional requirements and check applicable boxes. 3. Indicate Type or Location (Ducts, H dronic in Floor, Radiators, etc.) Tank Capacity (gal) WATER HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydropic space heating. Individual dwelling DHW heaters must be storage gas or propane fired, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage DHW heater less than 50 gallons with an energy factor greater than 0.90 maybe used. Hot water pipe insulation from the DHW heater to the kitchen(s) and on all under round hot water pipes is required in all component packa es in all climate zones. Heated Slab Insulation YES xl NO I Slab edge insulation required for heated slabs in all Climate Zones. See details in Table 118-A of the standards. Raised Slab Insulation r] YES [E NO Extemal Tank Water Heater Type/Fuel Type' Distribution Type (Standard, Recirculatin )z Number In System Tank Capacity (gal) Energy Factor or Thermal Efficiency Insulation R-Value3 EXISTING 1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc.) 2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do not allow the installation of a recirculating water heating system for single dwelling units. 3. The water heating tank and pipes shall be insulated to meet the requirements o §150 ). SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below. These items may require written justification and documentation and special verification. Applicable special features shall be marked with a YES and be specified within the plans. Radiant Barrier (Roof) El YES I El N07 Required in Climate Zones 2, 4, and 8-15 for additions larger than 100 W. Slab Edge (Perimeter) Insulation Q YES R NO I In Climate Zone 16 under Component Package D, R-7 insulation is required. Heated Slab Insulation YES xl NO I Slab edge insulation required for heated slabs in all Climate Zones. See details in Table 118-A of the standards. Raised Slab Insulation r] YES [E NO In Climate Zones 1, 2, 11, 13, 14 & 16 R-8 insulation is required, and in Climate Zones 12 & 15 R-4 insulation is required under Component Package D. Thermal Mass - To obtain Compliance Credit for the installation of thermal mass, use the Performance Approach. Registration Number: Registration Date/Time: HERS Provider: 2008 Residential Compliance Forms March 2010 Prescriptive Certificate of Compliance: CF -IR ADD Residential Additions (Page 5 of 5 Site Address: 80-715 VIA PORTOFINO Enforcement Agency: Date: 12/27/2012 CITY OF LA QUINTA HERS VERIFICATION SUMMARY - The enforcement agency should pay special attention to the HERS Measures specified in this checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final inspection. Duct Se ling & Testing HERS verification is re uired or this measure. YES NO In all Climate Zones, if a new space -conditioning system (HVAC equipment amd ducting) is installed to serve the addition Address: // CoIf C ApplicableE]CEA orE]CEPE alone, the ducts are to be sealed and tested per §151(010. (Certification #): City/State/ZipZ, q�. ^ ZZd 1 In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned n YES NO space to serve the addition, the ducts are to be sealed and tested per §I52(b)1D.[I EXCEPTION: Existing duct systems • I certify that the energy features and performance specifications for the building design identifies on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. that are extended, which are constructed, insulated or sealed with asbestos. building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (incl:.jding replacement of the air handler, outdoor Signature: condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) and will serve the addition, the ducts Date: 7.- 2— Address: Address: are to be sealed and tested per §I52(b)IE. Q YES [@ NO EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS verification in accordance with procedures in the Reference Residential Appendix RA3. EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space. EXCEPTION: Existing ducts stems constructed, insulated or sealed "ith asbestos. Refri erant Cha e - Split System HERS verification is re uired for this measure. YES ID NO In Climate Zones 2 and 8-15, if a newly ducted split A/C or heat pump is installed to serve the addition alone, a refrigerant charge measurement shall be verified per § 151 7A. In Climate Zones 2 and 8-15, if the existing HVAC equipment is replaced (including replacement of the air handler, outdoor YES E] NO condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) and will serve the addition, a refrigerant charge measurement shall be verified per § 152(6)1 F. Central Fan Integrated Ventilation System — Airflow and Fan Watt Draw - do not apply for additions 1,000 ftZ or less. Ducted Split Systems - Air Conditioners and Heat Pumps: Airflow and Fan Watt Draw HERS verification is required. YES Q NO In Climate Zones 10 through 15, if a new space -conditioning system (HVAC equipment and ducting) is installed to serve the addition alone, the airflow and fan watt draw shall be verified per § 151(f)7B. Q YES 0 NO In Climate Zones 10 through 15, if the existing space -conditioning system (HVAC equipment and ducting) is replaced and will serve the addition, the airflow and fan'watt draw shall be verified per § 152jb)IF. Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is accurate and complete. , . Name: ` - /y 14 � Signature: _o�h -rl r l� H O D Company : A-esDG a E V Date: Z 2 a / Z Address: // CoIf C ApplicableE]CEA orE]CEPE �i►V% /d 44 ;a (Certification #): City/State/ZipZ, q�. ^ ZZd 1 Phone: Responsible Building Designer's Declaration Statement` • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the building design identifies on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. • The building design features identified on this Certificate of Compliance are consistent with the i-iformation provided to document this building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name: Signature: Company: / Date: 7.- 2— Address: Address: License: , D 79��O r Z_ City/State/Zip: - Phone: For assistance or questions regarding the Energy Standards, contact the Energy Hotline as 1-800-772-3300. Registration Number: 2008 Residential Compliance Forms Registration Date/Time: HERS Provider: March 2010 ELECTRICAL LOAD CALCULATIONS 4/24/2012 NAME OF PROJECT: Richey Residence, The Hideaway LOCATION : 80715 Via Portofino, La Quinta LIVABLE GROSS AREA: 4,697 SF. GARAGE AREA: 949 SF. ITEM: ITEM TOTAL WATTS 4,697 20 circuits small appliances circuits LGA @ 3 watts/sf. 14,091 1 dishwasher @ 1500 watts 1,:00 1 garbage disposal @ 900 watts 900 1 trash compactor @ 900 watts 5`00 1 refrigerators @ 600 watts E00 1 freezer @ 500 watts E00 2 u.c. refrigerator @ 500 watts 1,C00 2 microwave@ 1500 watts 3,C00 1 double ovens @ 500 watts °00 1 cook top @ 7600 watts 7,E00 1 clothes washer @ 800 watts E00 1 clothes dryer @ 6000 watts 6,000 1 laundry circuit@ 5400 watts 5,400 4 FAU 2000 watts 8,000 3 pool equipment 1500 watts 4,500 1 yard lighting 6000 watts 6,000 949 garage LGA @ 5 watts/sf. 4,745 Sub total : 66,(336 watts 1st 1 O watts@ 100% remainder @ 40% sub total : air conditioning 17 tons @ 1,720 watts/ton total wattage RECOMMENDED MSB SIZE: 400 AMPS 10,000 22,414 28,161 watts 29,240 watts 53,961 watts Total load demand: 53,961 watts Voltage : 240 volts Minimum Amps: 225 amps CURRENT USAGE TITLE 24 REPORT I Title 24 Report for: Andy Williams Residence 80715 Via Portofino La Quinta, CA 92253 Project Designer: Kristi Hanson Architects, Inc. 72-185 Painters Path Suite #A Palm Desert, CA 92260 760-776-4068 Report Prepared By: Gina Rose G.R. Rose CAD Design 42335 Washington Suite F #330 Palm Desert, CA 92211 (760) 345-4859 Job Number: Date: 12/9/2004 of -8, s�` oE 61VAF 5tp_01NG ED o��Vkov"-"STROC c� B The EnergyPro computer program has been used to perform the, calculations summarized in this compliance report. This program has approval and is Authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. , EnergyPro 3.1 . By EnergySoft Job Number: User Number: 5862 1 Certificate of Comoliance: Residential (Part 1 of 2) CF -1 R Andy Williams Residence 12/9/2004 • Project Title Date 80715 Via Portofino La Quinta Project Address Building Permit # G.R. Rose CAD Design (760) 345-4859 Plan Check / Date Documentation Author Telephone Computer Performance 15 Feld Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,423 ft2 Average Ceiling Height: 10.9 ft Total Conditioned Slab Area: 4,423 ft2 Building Type: Wood (check one or more) Exterior Roof X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northeast) 45 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Ccmments (attic, garage, ypical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimete, Insulation Solid Wood Door Wood 0.387 Exterior Door FENESTRATION Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (Southeast) 48.3 0.60 0.50 Bug Screer ❑ X❑ X❑ ❑ Rear (Southwest) 339.0 0.60 0.50 Bug Screer: ❑ X❑ ❑X❑ Right (Northwest) 46.0 0.55 0.43 Bug Screen. ❑ X❑ ❑ X❑ Right (Northwest) 16.0 0.55 0.45 Bug Screen ❑ X❑ ❑ X❑ Front (Northeast) 114.0 0.60 0.50 Bug Screen ❑ X❑ ❑ X❑ Front (Northeast) 214.1 0.55 0.43 Bug Screen ❑X❑ ❑X❑ Left (Southeast) 215.2 0.55 0.43 Bug Scree■❑ X❑ ❑ X❑ Rear (Southwest) 67.5 0.55 0.43 Bug Screen ❑ X❑ ❑ X❑ Rear (Southwest) 24.0 0.55 0.45 Bug Screen ❑ X❑ ❑ X❑ Right (Northwest) 50.0 0.60 0.50 Bug Screen❑ X❑ ❑ X❑ Right (Northwest) 8.0 0.55 0.45 Bug Screen❑ X❑ X❑ ❑ Front (Northeast) 12.5 0.55 0.45 Bug Screen ❑ X❑ ❑ X❑ Run Initiation Time: 12/09/04 13:08:37 Run Code: 1102626°17 Ener Pro 3.1 By Ener Soft User Number: 5862 Job Number: Page: 3 of 45 0 • Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Andy Williams Residence 12/9/2004 Project Title Date 80715 Via Portofino La Quinta Project Address Building Permit # G.R. Rose CAD Design (760) 345-4859 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,423 ft2 Average Ceiling Height: 10.9 ft Total Conditioned Slab Area: 4,423 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northeast) 45 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component FENESTRATION Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc. Shadilinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (Southeast) 138.0 0.60 0.50 Bug Screer ❑ X❑ ❑ x❑ Left (Southeast) 22.6 0.55 0.45 Bug Screer ❑ X❑ ❑ Q ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 12/09/0413:08:37 Run Code: 1102626°17 Ener Pro 3.1 By Ener Soft User Number: 5862 Job Number: Pa e:4 of 45 • • Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Andy Williams Residence 12/9/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments r]entral Furnarp 80% AFUE Ducts in Attic 42 Setback Master Suite Central Furnace 80% AFUE Ducts in Attic 42 Sethack Living Area Central Furnace .80% AFUE Ducts in Attic 4.2 Setback Bedrooms Central Furnarp 80% AFUE Ducts in Attic 4.2 Setback Guest Suite Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Setback MastPr SuitP Split Air Conditioner 13 0 SFFR Ducts in Attic 42 Setback I iving Area Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Bedrooms Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Guest Suite WATER HEATING SYSTEMS Rated 1 Tank Enercy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A n SMITH CDVH 75 Small Gas Recirc/Time+Temp 1 75„000 75 U88 n/a n/a For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency aril Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Kristi Hanson Architects, Inc. Address: 72-185 Painters Path Suite #A Palm Desert, CA 92260 Telephone: 7601776-4068 Lic. #: (signatur (date) Enforcem nt Agency Name: Title/Firm: Address: Telephone: Name: Gina Rose Title/Firm: G.R. Rose CAD Design Address: 42335 Washinqtor Suite F #330 Palm Desert, CA 92211 Telephone: 1760)_345-4859 nature) (date) IEnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:5 of 45 1 4 4 Certificate of Compliance: Residential (Addendum) CF -1 R 12/9/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approac.l. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleep, ng Areas. The HVAC System "Master Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Resident;al Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 484 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 576 sqft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Area" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Living Area" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2268 sqft Exposed Slab Floor, 4.00" thick at Zone 2 The HVAC System 'Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System 'Bedrooms" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 148 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 385 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 3 f IGH MASS Design(see C -2R) - Verify Thermal Mass: 106 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 3 IGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sqft Exposed Slab Floor, 4.00" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEG approved HERS Plan I Field proviaer. i ne ntrczi rater must aocument the tiew ventication ana aiagnostic testing of tnese measures on a torm cF-6R. Plan Field The HVAC System "Master Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide erifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Area" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Area" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System 'Bedrooms" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System 'Bedrooms" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. IF Run Initiation Time: 12/09/04 13:08:37 Run Code: 1102626517 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:6 of 45 Certificate of Compliance: Residential (Addendum) CF -1 R -Andv Williams Residence 12/9/2004 roject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approac..l. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 607 sqft Covered Slab Floor, 4.00" thick at Zone 3 The HVAC System "Guest Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleepieg Areas. The HVAC System "Guest Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 125 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 141 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 90 sqft Exposed Slab Floor, 4.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 198 sqft Covered Slab Floor, 4.00" thick at Zone 4 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HER5 rater must document the field verification and diagnostic testing of these measures :)n a form GF -6R. Plan Field The HVAC System "Guest Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage erformed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. (EnegyP�ro#.l Run Initiation Time: 12/09/0413:08:37 Run Code: 11C2626517 By EnergySoft User Number: 5862 Job Number: Page:7 of 45 C] • • Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Complianca. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X '§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑X not apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no a greater than 2.0 perm/inch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. a§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:8 of 45 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance ap )roach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into • the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X] -§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed. ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5862 Job Number: Page:9of 45 Computer Method Summary (Part 1 of 3) C -2R 121-9/20-04 Date Building Permit # G..B__BoseQ.AD_Design (760) 345-4859 Documentation Author Telephone Plan Check/Date �ompuierer%cmaace 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.31 2.97 1.34 _0-059 0- Space Cooling 39.34 41.72 -2.38 90_ Domestic Hot Water 6.44 3.80 2.65 Wall_ 97_ Totals 50.10 48.49 1.61 -0.0.59 _31.5. Percent better than Standard: Roof- _2,266 3.2% 0 Wall_ 315 BUILDING COMPLIES 90 Total Conditioned Floor Area: 4,423 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached 90_ Wall_ 29Z Building Front Orientation: (Northeast) 45 deg Total Fenestration Area: 29.7% Number of Dwelling Units: 1.00 90 Total Conditioned Volume: 48,111 ft 3 Number of Stories: 1 Wall- ----14.8_ Total Conditioned Slab A. -ea: 4,423 ft 2 BUILDING ZONE INFORMATION Zone Name -MasteLS.uite LivingA_ ren edrooms _uesiSu.ite OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt # of Floor Area Volume Units Zone Type Roof_ 0 0-60 0..02.5 0 0 Wall 57 _0-059 0- 90_ Wall_ _237 _0_0.59 ___A5_ 90_ Wall- 594 0.059 035 90 Wall_ 97_ -0-059 _22.5 90 Wall_ ------ 20_ -0.0.59 _31.5. 9.0 Roof- _2,266 0 25 0 0 Wall_ 315 0.059 45 90 Door_ 24 0-.87 ____4.5 90_ Wall- X20_ -0.0.5.9 _135 90_ Wall_ 29Z -0,059 -225 _90- 0Wall Wall393 0-069 315 90 Root 0,26.3 -0-025 0_ 0_ Wall- ----14.8_ 0,059 _45 90_ Wall_ 38.5 _0-0.59 135 90_ Wall_ X06. 0-5.9 _225- -90 Wall 110_ -0_0.59 _315 9.0_ Roof _28.8_ -0_028_ 0 0_ Wall- X25 0.059 ---A.5 90 Wall- x41 -0-059 035 90 Wall_ 22 -0-059 22590 Wall_ _226_ -0_059 _31.5_ -90_ • 109 2,26.8 8.07 2.68 Solar Gains Y/N X1,925 -0.24_ Sleeping _2-4,.948 -0-5-1- Living _8.07_0 0_1.8_ Sleeping _3,168 _0_Q7_ Sleeping_ Form 3 Reference _LZ38Roof (R.38_2x14.16) .R-2_t_Wall W_21.2x6.1.6) R-21 MIL(_W.21.2x616) R21 VVall_(YV_21.2x6J6) _R2LWalL(1N_.21_2x6J 6) .R_2] WaILpN_2J_ 161 R-38Roo (P_a8 2x1416) R2LWaIL(N_2J_2x6J 6) -Solid-Wood-Door .R2LWaIL(W_212x6_t6) R-21 WWL(W_.21..2x6 16) R-21 WaIL(W-21.2x6.16) _13--38 Roof (B 38.2x14.16) R-21 Wall (W21 2x616) R-_ZLMll jW21 2x6 l6) R_-21_Wall_(W.21..2x&_M R21_WalL(W.21..2x6J 6.) 1338Ronf_.R 8.82x]416) _R21_WalL(W 21.2x616) _-2LWall IW 21.2x 16) .R- LWalL(__W 21.2x616) R21_WalL(W_n2x6J_6a Zone, Zone 1 Zone 2 Zone -3 Zone -3 Zone_3 Zone 4 Thermostat Vent Type Hgt. Area _SleepingStat- _2 ____n/.a Liv;ng.Stat_ 2 -n/a -Sleeping-Slat- 2 _n/.a -Sleeping-Stat- 2 _n/a Location / Comments EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 10 of 45 1 Computer Method Summary (Part 2 of 3) C -2R 12/9/2004 # Tvpe Area J_ Window-Let-(S_outheast) -A8-3- 2 Window Rear (Southwest) 47.5 3 Window Rear (Southwest) 47.5 4 Window Right (Northwest) 3.8 5 Window Right (Northwest) 2.0 6 Window Right (Northwest) 2.0 Z Window Right (Northwest) 2.0 8 Window Right (Northwest) 8.0 9 Window Right (Northwest)22 _0 _1.0 Window Front (No_phea_st) ---6-0-0 11 Window Front (Northeast) 27.0 12 Window Front (Northeast) 83.3 13 W1ndoW--EEOIlt_(l\NOltlleast) 0.76 18 1-5- 14 Window Front Northeast) 1.5 15 Window Front Northeast) 1.5 16 Window Front (Northeast) 1.5 17 Window Front (Northeast) 1.5 18 Window Front (Northeast) 83.3 19 Window Front (Northeast) ---27-0- 70_20 20 Window Left (Southeast) 83.3 21 Window Left (Southeast) 83.3 22 Window Left (Southeast) 3.8 23 Window Left (Southeast) 40.0 24 Window Rear (Southwest) 200.0 25 Window Rear (Southwest) 1.5 26 Window Rear (Southwest) 1.5 27 Window Rear (Southwest) 1.5 Rear (Southwest) 1.5 aWindow Window Rear (Southwest) 1.5 INTERIOR AND EXTERIOR SHADING Ll - Factor -0-600- 0.600 0.600 0.550 0.550 0.550 -0- KO_ 0.550 0550 0.60.0_ 0.600 0.550 0-550 0.550 0.550 0.550 0.550 0.550 0.600 0.550 0.550 0.550 0.550 0.600 0.550 0.550 0.550 0.550 0.550 SHGC -0-50- 0.50 0.50 0.43 0.43 0.43 0.43 0.45 0.43 0..50 0.50 0.43 -0-4,3 0.43 0.43 0.43 0.43 0.43 0.50 0.43 0.43 0.43 0.43 0.50 0.43 0.43 0.43 0.43 04.1 Act. Azm. Tilt Glazing Type _A35_ _90. Fleetwood -Glazing 225 90 Fleetwood Glazing 225 90 Fleetwood Glazing 315 90 Fleetwood Glazing 315 90 Fleetwood Glazing 315 90 Fleetwood Glazing 315 9Q Fleetwood Glazing 315 90 Fleetwood Glazing 315 90 Flee wlQ9d Glazing 45 9Q Fleetwood Glazing 45 90 Fleetwood Glazing 45 90 Fleetwood Glazing ---A..5_ 90 Fleetwood - Glazing --45 90 Fleetwood Glazing 45 90 Fleetwood Glazing 45 90 Fleetwood Glazing 45 90 Fleetwood Glazing 45 90 Fleetwood Glazing 45 9Q Fleetwood Glazing 135 90 Fleetwood Glazing 135 90 Fleetwood Glazing 135 90 Fleetwood Glazing 135 90 Fleetwood Glazing 225 90 Fleetwood Glazina 225 90 Fleetwood Glazin 225 90 Fleetwood Glazing 225 90 Fleetwood Glazing 225 90 Fleetwood Glazing 225 90 Fleetwood Glazing Location/ Comments zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 1 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Zone 2 Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 9.5 5.2 0.0 0.0 0 0.1 2.0 0 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 _ 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 'Bug.Screen 0.76 21 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:11 of 45 1 Computer Method Summary (?art 2 of 3) C -2R # T Area Factor SHGC Act. Azm Tilt Glazing Type 12/9/2004 1 ate Location/ Comments _3.0. Wmdaw BeaL--(.S_outtwest) 240 _0_55D- -0.4.5 -225 -90. FleetN.00d_Glazing Zone 2 31 Window Rear (Southwest) 60.0 0.550 0.43 225 90 Fleetwood Glazing Zone 2 32 Window Right Northwest) 50.0 0.600 0.50 315 90 Fleetwood Glazing Zone 2 33 Window Right (Northwest) 8.0 0.550 0.45 315 90 Fleetwood Glazing Zone 2 34 Window Front (Northeast) 12.5 0.550 0.45 45 90 Fleetwood Glazing Zone 3 35 Window Left Southeast) 48.0 0.600 0.50 135 90 Fleetwood Glazing Zone 3 30 W_inldow Left_(aaQu haast) 4.9 0.550 0.43 135 90 Flegwood Glazing Zone 3 37 Window Left (Southeast) 11.3 0.550 0.45 135 90 Fleetwood Glazing Zone 3 38 Window Left_($outtieast) 11.3. 0.550 045 X35 _90 FJeetwwood_Glazing Zone 3 39 Win w Rear ( hw st) 44 0.600 0.50 225 90 Fleetwood Glazing Zone 3 4Q Window Front Northeast) 40.0 0.550 0.43 45 90 Fleetwood Glazing Zone 4 41 Window Left Southeast) 45.0 0.600 0.50 135 90 Fleetwood Glazing Zone 4 42 Wir dovv_Left-(_Southeast) 45..0_ Q_609 0...59 13, 90 Fleetwood -Glazing Zone 4 43 Window Right (Northwest) 1.5 0.550 0.43 315 90 Fleetwood Glazing Zone 4 44 Window Right (Northwest) 1.5 0.550 0.43 315 90 Fleetwood Glazing Zone 4 45 Window Right (Northwest) 1.5 0.550 0.43 315 90 Fleetwood Glazing Zone 4 46 Window Right (Northwest) 8.0 0.550 0.45 315 90 Fleetwood Glazing Zone 4 47 Window Right Northwest) 3.8 0.550 0.43 315 90 Fleetwood Glazing Zone 4 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 46 31 Bug Screen 0.76 Bug Screen 32 Bug Screen 0.76 33 Bug Screen 0.76 4.0 2.0 0.0 0.0 0 0.1 2.0 0 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:12 of 45 1 Computer Method Summary (Part 3 of 3) C -2R Andy Williams Residence Type Length Factor R -Val. Depth Location / Comments 12/9/2004 Iroject Title 93 0-M 0.0 0 Zone 1 Date THERMAL MASS FOR HIGH MASS DESIGN -01-6. 0.0 0 Zone 1 Slab Perimeter Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. Heavyweight 484 -4.0.O _28. _0..9.8. n/a 0 Zone-USlab_on-Gtade Concrete. Heavyweight 576 4_00 28 0_98 n/a 2 ?one 1 / Slab on Grade .Q9n-c-rate beavyw�ight 2,268 -4-00 28 -0-W n/a 0 ?one 2 / Slaljon r de Masonry Veneer 148 2_00 25 0_62 R-21 Wall (LN.21.2x6.16) 0 ?one 3 / Exterior Mass MasonryVeneer �$5 2�Q 2� O.Cz R-21 Wall (W.21 2x6.16) 0 ?one 3 / Exterior Mass PERIMETER LOSSES 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS F2 Insulation Type Length Factor R -Val. Depth Location / Comments SI�b PeLnieter 93 0-M 0.0 0 Zone 1 Slab-Berimeter 95 -01-6. 0.0 0 Zone 1 Slab Perimeter 18 016 00 0 Zone 2 SLab_P_eiimeter --10 O.B 0-0 0 Zone 'A _SJab-P-e.dmeter 78 00 0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic l e 4.2 ---aeSback&WeL uAle- Central Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Living Area Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Bedrooms Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Guest Suite �ydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Spit Air CQnditioner 14 2SEEB D_u9ts-hi ttic 4.2 S012ack Master Suite Split Air Conditioner 13.0 SEER Ducts in Attic 4.2 Setback Living Area Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Bedrooms Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Guest Suite WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. cx Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH CDVH 75 Small Gas Rech im +Temp— 1 75,000 75 0.8.6 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Computer Method Summary (Part 3 of 3) C -2R And Williams Residence 12/9/2004 kroject Title Cate THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (so (in.) Cap. Cond. Form 3 Reference Inside R -Val. Location Comments Masonry Veneer x_06. 20.0 _25_ _0_62 R2-1-Wall_(W 2]_2x6_16.)_ 0 Zone_ 3-LExteri.OLMas.S Concrete. Heavyweight 200 4_00 28 0_98 n/a 0 Zone 3 / Slab on Grade Concrete. Heavyweight 607 4.00 28 0 n/a 2 Zone_3 / Sit b on Grade Masonry Veneer 125 2_00 25 0_62 R-21 Wall (W.21.24.16) 0 Zone 4 / Exterior Mass .Masonry -\Leneer 141 U-0. 25 0.62 R-21 Wall (W 21.26.16 0 Zone 4 / Exterior Mass PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments .S_la_b Perimeter 15 0.76. 0.0_ 0 Zone 4 SJab_Betimeter ---A5. 026 —0-0. 0 Zone 4 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments loydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS Rated' Tank EQergy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy (factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standoy Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 12/09/0413:08:37 Run Code: 1102626517 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page:14 of 45 Computer Method Summary (Part 3 of 3) C-2R Andy Williams Residence 12/9/2004 roject Title Cate THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Con& Form 3 Reference R-Val. Comments C9u—rete Heav jght _90. -.0.0 _28 -0_9.8. n/a Q ZoaeALStab_on_Grade Concrete Heavyweight 198 4_00 28 0_98 n/a 2 Zone 4 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R-Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R-Value Type Comments 10ydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R-Value Type Comments WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R-Value System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (°/a) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Paae:15 of 45 1 Computer Method Summary (Addendum) C -2R 12/9/2004 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that 3therwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Master Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 484 sqft Exposed Slab Floor, 4.00" thick at Zone 1 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 576 sqft Covered Slab Floor, 4.00" thick at Zone 1 The HVAC System "Living Area" must meet all CEC Criteria for a Zonally Controlled system serving only Living Aeas. The HVAC System "Living Area" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2268 sqft Exposed Slab Floor, 4.00" thick at Zone 2 The HVAC System 'Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System 'Bedrooms" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 148 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zane 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 385 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zrne 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 106 sqft Masonry Veneer Exterior Mass, 2.00" thick at Zane 3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sqft Exposed Slab Floor, 4.00" thick at Zone 3 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Plan I Field proviaer. i ne ntKs rater must aocument the fiew vermcation ana diagnostic testing of these measures on a form GF -61R. 4 plan Field The HVAC System "Master Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide erifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Living Area" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS ra er must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Living Area" is using reduced duct leakage to comply and must have diagnostic site testing cf duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System 'Bedrooms" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System 'Bedrooms" is using reduced duct leakage to comply and must have diagnostic site testing o, duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. 1i EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 16 of 45 1 4 Computer Method Summary (Addendum) C -2R .Andv Williams Residence 12/9/2004 roject Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 607 sgft Covered Slab Floor, 4.00" thick at Zone 3 The HVAC System "Guest Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residentia Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 125 sgft Masonry Veneer Exterior Mass, 2.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 141 sgft Masonry Veneer Exterior Mass, 2.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 90 sgft Exposed Slab Floor, 4.00" thick at Zone 4 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 198 sgft Covered Slab Floor, 4.00" thick at Zone 4 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HER5 rater must document the field veritication and diagnostic testing of these measures cn a form GF -6R. plan Field The HVAC System "Guest Suite" is using reduced duct leakage to comply and must have diagnostic site testing •if duct leakage erformed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 12/09/0413:08:37 Run Code: 1102626517 EnergyPro 3.1 By EnergySoft User Number: 5862 Job Number: Page: 17 of 45