Loading...
04-7939 (SFD)c��o (760),777.7'012 78 495 CALLS TAMPICO. r• ; c��o (760),777.7'012 78 495 CALLS TAMPICO. FAX (760) 777-7011 LA •QUINTA"•, CALIFORNIA 92253, INSPECTION. REQUESTS (760) 777-7153 BUILDING PERMIT Application Number 04-0000 939 Date 12/29/04 Property. Address , . 7825-0 VIA PAVION :APN:. 604 -032 -999 -10 -305212 - Application description DWELLING— SINGLE FAMILY DETACHED Property Zoning . . . LOW DENSITY RESIDENTIAL Application valuation 166563 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, STE C. 78401 HIGHWAY.111, SUITE C LA.QU°INTA, CA SLA QUINTA, CA 92253 LA.QUINTA;_ CA 92253 .(9.51)817-3600 WCC: AON RISK SRVC WC:. MWC11114500 11/01/05 CSLB: .728102 09/30/06 .CCC: :. B' 1, 0 'k .. P.O. Box 1504 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 <l10. C BUILDING & SAFETY DEPARTMENT f A 11 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Application Number: D q— 793 9 Date: Applicant: Applicant's Mailing Address: ArchilT gineer: --Architect or Engineer's Address: Ic, No.: 'BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Cod , and ss Licen i II force and effect. ��,, Z_ _6L6 rcense Class /` ""'e No. t ate -6--C—.ntractor OWNER$UILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the. owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.): U I am exempt under Sec. , BA P.C. for this reason Date Owner. WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and II intain workers' compensation insurance, as required by Section 00 of the Labor Code, for the perfomrance of the work for which this permit is i Aorkers' compensation surence pri ppgl nymph► artier T \� Policy _ 1 ce ity that, in the perfomman a of the work for which this permit is issued,.I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /ate Applicant r WARNING: FAILURE TO SECURE WORKERS' C P NSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN, EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND D RS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct I agree to comply with all city and county ordinances end state laws relating to building construction, and hereby authorize representatives of thisco t to enter upon above mentioned property for inspection purposes. Date - V Signature (Applicant or Agen 171- Application Number ---------------------------------------------------------------------------- 04-00007939 ----.---------------------- Structure Informat-ion -----------------.-------- Construction Type . . . . TYPE V'- NON RATED Occupancy Type DWELLG/LODGING/CONG.<=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE' Other struct info-. CODE EDITION 2001 CBC FIRE SPRINKLERS NO GARAGE SQ FTG, 682.00 PATIO SQ FTG 358.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 2595.00 Permit . . . . . . BUILDING 'PERMIT Additional desc Permit Fee . . . . 874.00 Plan Check Fee 568.10 Issue Date. . Valuation .166563 Expiration Date 6/28/05 Qty Unit Charge. Per Extension BASE FEE' 639.50 67.00, 3.5000 ----------------------------------------------------------------------------- THOU BLDG 100,001-500,000 234.50.. Permit . . . . MECHANICAL Additional desc . Permit Fee . . . . 52.50 Plan Check Fee 13.13 Issue Date Valuation 0 Expiration Date 6/28/05 Qty 'Unit Charge Per. Extension BASE FEE 15.00 . 1.00 - 9.0000 EA MECH FURNACE <=100K 9.00 1.00. 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc , Permit'Fee 119.47 Plan Check Fee,.' 29:87 Issue Date Valuation . . 0 Expiration Date '. 6/28/05. Qty Unit Charge Per Extension. BASE FEE 15.00 .2595.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 90.83. 682.00 .0200 ELEC"GARAGE OR NON-RESIDENTIAL 13.64 Permit PLUMBING Additional desc.. Permit.Fee 171.75 Plan Check Fee 42.94 Issue Date Valuation 0 " Expiration Date 6/28/05 Qty Unit Charge, Per Extension BASE FEE 15.00 17.00 6.0000 EA PLB FIXTURE 102.00 1.00 15.0.000 EA PLB BUILDING SEWER 15.00 `.Application Number . - - - - - - - -' - - - - - - - - _. - - ---------------- ---------------`.Application . . . . 04-00007.939. Permit . . . . . . PLUMBING Qty Unit Charge, Per., Extension 1.00 7:5000 EA -PLB WATER HEATER/VENT 7.50 1.00 3.0000, EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000'EA PLB LAWN, SPRINKLER;SYSTEM 9.00 7.00 .7500 EA PLB' GAS PIPE >=.5 5.25 . 1.00 15.000.0 EA PLB GAS METER 15.00. Permit . . . . GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee . .00. Issue -Date Valuation 0 Expiration Date.. 6/28/05 Qty Unit Charge Per Extension BASE ' FEE 15.00 Special Notes and Comments SFD = LOT 10, PLAN 2X, 2595 SF.,PERMIT DOES NOT INCLUDE POOL, SPA;. BLOCK WALLS OR DRIVEWAY APPROACH Other Fees . . ART TN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF .CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 56.81 DIF FIRE PROTECTION -RES 97.00 ,GRADING PLAN CHECK FEE .b 0 ` DIF .LIBRARIES - RES 225..00 , DIF PARK MAINT•,FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) -*RES 16.65 DIF STREET.MAINT FAC -RES. 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due Permit Fee Total 1232.72 .00 00 1232.72 Plan Check Total 654.04 .00 .00 654:04'._ Other Fee Total 2478.46 .00 .00 .2478:46 Grand.Total 4365.22 .00 .00 `4365.22 n CER4VICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 'n C - `LA QUINTA DEL ORO PH- 8 6-14-05 8 -� Project Title Date 78250_V_ is P,av_ ion, La Quinta, CA 92253 LENNAR Project Address Builder Name Nacho Castenada 76ee��0-578-6968 Plan 2XR (pg. 1 of 1) Buitder_Clt3plaactm Henson (CCN #CC2004076) 76U 508 7022 P1aGro p 6 HERS Rater Telephone Sample Group Number 6-14-05 10 (ph 8) Certifying Signature Date Sample House Number Fes: BCI Testing HERS Provider: CALCERTS Street Address: ' PO Box 50575 city/state/zip: Phoenix, AZ 85076 Copies to: Builder, HERS Provider HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF-6R (Installation Certificate. ❑ Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ , Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results. (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) _ Check Box for Pass or Fail (Pass=6% or less) ❑ ❑ Pass Fail ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ Yes is a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT I ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF-1R and design on plan. 2• ❑ Yes ❑ No . TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF-IR. Measured Fan Flow = ❑ ❑ Yes for both 1 and 2 is a Pass Pass Fail Compliance Forms August 2001 A-16 Certificate of- . insulation a Your home has been insulated with John Msnevilte Flberalas insulation products, which are designed for today's safety standards and tomorrows energy requirements. Fiberglass is inorganic and thereforepermanently noncombustible, so it does not have to be treated .with fire-retardant chemicals that will-likely lose their effectiveness over time. It has not been treated with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it settle over time as may other insulation materials. rofessionally Installed in this home to provide the This also certifies that insulation have been p following thermal performance. - Lannar Homes Job Name: La Quinta Del Oro Tract: 30521 Plan# 2XR � Phase: 8 ' Lot No: Job Address: SFR - 78-250 Via Pavion, La Quints, CA - Ceiling Area: "R-38 blown`and batt insulation Garage Ceiling: - Non -Access: _ • - With Living Above i Sloping Areas Exterior Walls R-13 batt insulation t3ver4ange: Access Attic: With Living Above Between Floors: Interior Walls: Subcontractor:.. ® J ins-Ulatign. inc. y 72-227 Adelaid St, Thousand Palms, CA 92276 Signed: Miike Dickerson,, General Maiwger - Palm Springs Division Y •� R-means resistance to heat flow. Ttie higher the R-value, the greater the insulating power. Ask your. builder for the- fact sheet on 'R-values: Keep -this certificate with your-other cate should, be passed on to the buyer. valued papers: If you ever sell thi's home, this certifi fir'., ':- . .. •._ - _ - ,. , - ., - _ � _ � .. .. -.. - } L Southwest Inspection and Vesting, Inc. 10826 South Norwalk Blvd., Santa Fe Springs, CA 90670 (562) 941-2990 • (714) 526-8441 - Fax (562) 946-0026 REGISTERED INSPECTORS'S DAILY REPORT146116, SWIT Job No. Daie Z- 4 -o S TYPE OF Reinforced Concrete ❑ Stractural Steel Assembly ❑ Quality Control INSPECTION ❑ Post Tensioned Concrete ❑ Fire Proofing ❑ Other REQUIRED ❑ Reinforced Masonry ❑ Asphalt Job Address / 0 %, T / ► City a U v �D�oiv 1A/�- Job Name 0 Pe��. 3 Issuedly .,LO �(> >v� ,A Type of Structure c � ,�j J !, L Architect / a /L)O Material Description (type. grade, source) coo .'JCe Engineer 5 FIN ,E Contractor ANN A40 /Lf e Inspector(s) Name/� ; frE AJ `` Subcontroctor, x.).7;:_-:JQ S C_G R� TESTS PERFORMED TYPE OF SAMPLE SLUMP QUANTITY IN SET ADDITIONAL REMARKS ON SAMPLES INSPECTION SUMMARY — LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT- AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADEH..T. BOLTS TORQUED) CHECKED, ETC. fT. So G W G r S <20 Z, 3i; 5 a �iCS �ee c5 c tit ke; e-0 l edq 74',E 1 2 A" 7Lr f s ; ( 440, . G U C/ Let H..S e c i l=0. ( oivs `t -e. CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS 0 NOTED. I HA FOUND THIS WOO 0 COMPLY WITH THE APPROVED PLANS, SPECIFICAT APPLICA t,E SE ONS OF THE ING BUILDING LAWS. SIGNATURE OF REGISTERED INSPECTOR Cr /C /O 111C11 c �) 6 Z ;73,t-0 117 SPECIALTY NO. AGENCY CONTINUED ON NEXT PAGE ❑ PAGE 2- OF I TIME IN. I TIME OUT I REG. HOURS 1 O.T. HOURS I CYLINDERS All inspections based on a minimum of 4 hours and over 4 hours - 8 hour minimum. In addition, any inspection extending past noon hour will be an 8 hour minimu Approved by Project WHITE - OFFICE COPY, CANARY - ACCOUNTING COPY, PINK - INSPECTOR'S COPY, GOLDENROD - JOB SITE COPY .: .