Loading...
0105-241, 0201-051 (SFD)N LJ o=) ir�_ Q ' Lr, �Z 0 C6O, H� J r Iw— a CD Z M LO N ON U 0) d Q Z LoaCr 0 LL 0 J J mQU OU d M H �t Z_ Cb Z C) J Q LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of „Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date fro Lit * toyf ryJ v4Yi' ,/f Va�A.7 Y T,bi Datee' Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code).. () I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations:. ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier (� Cj Policy No. fiiMEM (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions;of Section 3700 of the Labor Code, I shaU°fo hwith comply with Iise provision9 .. Applicant, -41 1.'�''i6_11" ll Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $1001000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall; indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such .permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property"..f - � inspectign purposes. ,. Signature (Ownul... t)� �'-'�-'•f�` Date' �' BUILDING PERMIT PERMIT# DATE VALUATION LOT 010&,241 TRACT q�«�p ��� y t y /y �1 7fn.7 I6n1ii. .AWiD..+%7W sJel 17 tl A 0 JOB SITE APN ADDRESS 77-570 CALLF ENSM* ADA 773-26-011, OWNER CONTRACTOR / DESIGNER / ENGINEER .TAL'%b McUM72.7 DESERT COV -1- DEV IJ O- CONSrRUCMON DE9.it.f3N S STEL D40 P0 BOX 6128 P, 01 Bux, 628 LA-,,) rbk CA 9225: LA QUIVYA CABS. 9225: �l�tl 1'7��3 93 C-BLO. 5830 USE OF PERMIT wa.9011IT.ldLLY DK4VIILT n�q0 .0D a Pl'#d.MIT I1023 AirW :NCLIJOY, 81=K WAf..r,,/MC2U:yPA OR I-RiV[FWAY A.P'PROACH, 7S% PLAf CIMCK, FFAt A.P1y1(.rlED FOR Mai'i1°l."t7 WZLIAMCF, OF SAME PLA33 'l"tt`PiL TRACT CONSTRUCTION 11591.00 sp PORC A:710 02.00 SF WORA09 ,9ST,an.'.AC3..6JLtaD T^05,i 0Y tjONIS$dt6rolC.vrI JiW C.�.,O�.�N217�RUCT�IO�Nir 99-000-4ap ypg }eft IU�l 01-000-4184M P.AAIt:KrW-It.:F9J? 101-000-4.39-418 da .a6 P& I)EP001T 101.000,439.318 MKI'MANacALIJJ10, 101-000-421-•000 $60.00 BLECIMUCIAL FFA 101 -000-4204*0 311339 PL fJ%f BA11a0 t913 101-000-419-000 $1136.09 QRAZIIINI C ITS 101-000-47-3-000 $30.00 DSVY�VAPER IMPACT FIRS $1,497,00 PR-RCISEPIAH 101-000-443-345 $iOO.gO LaU—7-C i'AL 4wC3>UrrRUCO'ION!AND ';LAMEL-K $3,1115.99 1=2 YRX-PAW "-TZ ,i J ' JC 7.'n rS Dv INE NOW 42501.00 r v1 bi AY 3 1 2001 CITY OF I A QUIN16 REC IPT FI Rey€E EPT f BY D FINAirG INSPE 0 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Slab Grade / / (p �` l � Ducts Return Air Steel Roof Deck O.K. to Wrap _ Q �� $r" _r' Combustion Air Exhaust Fans F.A.U. Framing cam' Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation . Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final POOLS - SPAS BLOCKWALL APPROVALS Steel Set Backs/ Footings Bond Beam _ �1 /�v( _ Electric Bond Main Drain Approval to Corer Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Waste Lines Gas Test Electric Final Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster S�"•�� -at Sewer Con/.ection / yl �V Pool Cover Encapsulation .:... pIng Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) 77 a 1' CITY OF LA QUINTA BUILDING & SAFETY DEPARTMENT ��CFbOF Ftp ` 777-7012 INSPECTION REQUEST LINE 777-7153 Owner Contractor In Permit Number POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS TYPE OF INSPECTION DATE INSP. FOUNDATION & SETBACK ' 3� FOOTING STEEL&WW Qp Z=/ MAIN GROUND SYSTEM GROUND PLUMBING ✓ PRE-GUNITE 00 NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED CONCRETE SLAB JOISTS & GIRDERS ELECTRICAL GROUND WORK DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED ROUGH ELECTRIC ROUGH PLUMBING ROUGH GAS & GAS TEST HEATING & VENT - A/C FIREPLACE ROOF BOND BEAM og O.K. TO WRAP GROUT ❑ 4' ❑ 8' FRAMING INSULATION ?% PRE -ROOF COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED DRYWALL INTERIOR EXTERIOR LATH POOL PRE PLASTER POOL FENCE & GATE SEWER SEPTIC TANK FI ELECTRICAL PLUMBING FINAL GAS TEST HEATING - A/C HOUSE NUMBERS JOB COMPLETED TEMP POWER ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING 1 %CLTy�q��`�A QUINTA 3•U LI D�ING ETY DEPARTMENT � 77-701 Z \INS'PECTI'QN REQUEST LINE P Permit Number 0105-241 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 77-570 CALLE ENSENADA SFD - PERMIT DOES NOT INCLUDE BLOCK WALL/POOL/SPA OR DRIVEWAY TYPE OF INSPECTION DATE INSP. FOUNDATION 8 SETBACK FOOTING STEEL MAIN GROUND SYSTEM GROUND PLUMBING PRE-GUNITE DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED 1 CONCRETE SLAB – JOISTS 8 GIRDERS ELECTRICAL GRO ND WORK DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED. ROUGH ELECTRIC ROUGH PLUMBING + ROUGH GAS 8 GAS TEST y HEATING 8 VENT- A/C FIREPLACE.;-„ ROOF p -p BOND BEAM O.K. TO WRAP 7&`z' S GROUT ❑ 4' ❑ 8' FRAMING — 6 •Dl _17 INSULATION 1 t9 PRE -ROOF • P/ COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED DRYWALL INTERIOR EXTERIOR LATH POOL PRE PLASTER POOL FENCE 8 GATE,,-- ATE:--SEWER SEWERSEPTIC TANK 3 - d2 FINALS. E ELECTRICAL F- PLUMBING FINAL GAS TEST F HEATING - A/C In HOUSE NUMBERS J' _ JOB COMPLETED T TEMP POWER ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING i s CITY -.OF LA QUINTA BUILDING &SAFETY DEPARTMENT OFT'° 777-7012 INSPECTION REQUEST LINE 777-7153 DESERT COVE DEVELOPMENT, LLQ Owner PAULDEN EVANS DESIGN INC. Contractor 0201_05 1 Permit Number POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES /-370 CALLE ENSENADA JOB ADDRESS SUPPLEMENTAL PERMIT TO REFLECT CHANGE OF CONTRACTOR (ORIG. PERMIT # 0105-241) TYPE OF INSPECTION DATE INSP. FOUNDATION 8 SETBACK FOOTING STEEL MAIN GROUND SYSTEM GROUND PLUMBING PRE-GUNITE DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNE CONCRETE SLAB JOISTS 8 GIRDERS ELECTRICAL GROUND WORK DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNI ROUGH ELECTRIC ROUGH PLUMBING ROUGH GAS &GAS TEST HEATING 8 VENT - A/C j FIREPLACE ' ROOF BOND BEAM O.K. TO WRAP GROUT ❑ 4' ❑ 8' FRAMING INSULATION { PRE -ROOF i'COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED 3 DRYWALL INTERIOR I EXTERIOR LATH POOL PRE PLASTER i POOL FENCE 8 GATE SEWER SEPTIC TANK ! FINALS ELECTRICAL PLUMBING FINAL GAS TEST HEATING - A/C HOUSE NUMBERS JOB COMPLETED TEMP POWER ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under, provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date �I s21 �r8 FitO fi". aa� Date Via. �^ Signature of Contractors 9 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole' compensation, will do the work, and the structure is not intended or offered for., sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). () I am exempt under Section `• B&P.C. for this reason Date Signature of Owner 9, WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: . ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by'Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. y(rj+) 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carver STATE COMP . Policy No. IMM -99 (This section need not be completed if the permit valuation is for $100.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation pro isions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.n. Date:k- :s APPlicanN . I--,' "I Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to. the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application -is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not •commenced within 180 days from date of issuance of such permit, or cessation of work.for 180 days will subject permit to cancellation. I certify that I have read this application and state that the.above information is correct. I agree to comply with al`.City; and State laws relating to the building construction, and hereby authorize representatives of th s -City to enter upon the above-mentioned property for inspection purposesr'~ Signature (Owner/Agent) �''+t"� =• ''' Date�'�'�'� V BUILDING -PERMIT PERMIT# DATE VALUATION LOT 0201-051 TRACT TIN JOB SITE APN ADDRESS 77-570 5 A'p• X ER ry 774-085-024 y082 OWNER CONTRACTOR/DESIGNER/ENGINEER DVZVKr COVE IDEM > OPWNT LLC: Pl�.i�'.l'.;D. MkISVARS DRSIGil INC. 18401 HIGHWAY } I I , ZUE F2 P101 BOX 621 LAQa[3OT'rA 'a F1 92253 RT'Mia.ME, CK 92501 USE OF PERMIT IMCM-LAN MMB sU1�3��L.i�.1��13'f'.t3%, �'.�;�f�� � 'f`d3 aa>���:t;:� s�rr,��a���, �N �:nt�r'y I�Ca•�:z.�. (�tl�.�. . l'ENT.MIT # 0105-241) i ERR:YAY$110) L+67U M ft. fO./.2$giRUC.f..Y.014 y OAX) P 1�i T •i" 'SrUMMA £Y SOPPLINDiTAL PERMIT FEE I 01A,0 -423i-000 $4,50 d' s D A JAN u 9 `2002 CiTuYO�pRApQ� iMIA I�704➢+i °9�e�i�tls'o- MYR-7 :MAL COM�i:.T.IC SION A.N'b PLAN CMUZY, yy$4.50 RECEIPT DATE JJ /f BY DTE FIN ED INSP INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall = Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Pibg:-Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: Certificate',of -Occupancy City of La Quinta Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the time of issuance, this structure was in compliance with the various ordinances of the City regulating'building construction or use. For the following: BUILDING ADDRESS: Use Classification: Occupancy Group: SINGLE FAMILY DWELLING R-3, U-1 77-570 CALLE ENSENADA Type of Construction: VN Bldg. Permit No.: Land Use Zone: Owner of Building: JACK MCKENZIE/DESERT COVE Address: PO BOX 628 DEV. LLC Building Official 0105-241 RC City: LA QUINTA, CA 92253 By: KIRK KIRKLAND Date: 2-12-2002 �,�, - -, ��Gv / c C P.O. BOX 1504 Building ) 614. i n �� fns 78-495 CALLE TAMPICO Address G-- , �, QUINTA, CALIFORNIA 92253 Owner, k k i4l' lailing Address CityG A Zip 'I ► -Y_ State Lica City & Classif. �� 7oIV% Lic. # Arch., Engr., f Designer Joe,_tel l ribo6 City _' ` Zip, (Q&(J State Q t�1..J.}� Lic. #f LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 olithe Business-and,,Professions:Codei and mylieense is in full force and L 1 OWNER-13UILDER DECLARATIOPf 1. hereby.affirm that I am exempt from the Conlractor'slicense law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for thealleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than live hundred dollars ($500). [2 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I 1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractors) licensed pursuant to the Contractor's License Law.) I l I am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company n Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: g, after making this Certificate of Exemption you should become subject tothe Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name- Lender's ame Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of aVPlicant Date Mailing Address City, State, Zip (?� APPLICATION ONLY � c�S r l� 1. Number 11 / �- �/1� U Reil �f /�— f )al Description��/ / 4 eject Description SED Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS r ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback rZt.8ear Prop. Line Side Street S:1P from r Line Side Setbac rroperty 16fie FINAL DATE IECTOR Issued by: aie�J/d)Lf�rm Validated by: �� ���f'Il//ii < y Val I.. WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION VU/NTA---_j or Dip[ RC DISTRICT - PLANNING REVIEW FORM This form is to be used by CDD staff for review of single family dwellings in the RC (Cove Residential) District, in order to determine the applicability of compatibility issues or need to require the filing of Master Design Guidelines by the applicant. It shall be transmitted to the Building and Safety Department as your correction list. Please attach additional explanations as necessary. , APPLICANT Construction Design Systems SITE ADDRESS 77-570, Calle Ensenada APN 773 _ 262 _ 011 ' BINNO.: 7L CASE NO.: 2001-432 LEGAL: LOT 12 BLOCK UNIT 10 S.C.@V.L.Q. CHECKED BY: Fred Baker DATE: Inform the assigned Building plan checker upon your assignment to this case. The CDD Executive Secretary maintains a log book to track applications and assign case numbers. REQUIRED ITEM Y N COMMENT/CORRECTION , Compatibility Review Case logged and number assigned Verify legal and APN information Consistent with MDG on file (as.applicable SEP MDG filing required (5 filings since 9/3/98) Consistency with street/surrounding area: Colors • Materials Architecture BY CC M�NIZY D ` O BY CASE �C• . Other Requirements: I 77-S 7 0 auc FA ��� f��itrGV P.O. BOX 1504 Buildingb_f. �/j �� 78-495 CALLE TAMPICO Address 77 !r' /1 �i> I/1/a h_�� � QUINTA, CALIFORNIA 92253 )%a C I l"`; Mailing Address -�,. City/ (-.,1 Zip �C Tel. zo J7.7135'�J State Lic. r� i y 8 Classif. f b U� Lic. N Arch., Engr., ' e Designer. I el ;ity -- Zi ��Q/0 ! 1 State P L . � : QV Lic. q• } J! LICENSED C TRACTOR'S DECLARATION I hereb ifl 'that I am licensed end provisions bf Chapter 9 (commencing with Section TODD) of onA 3 o/t,�th BusinesQ7/ nd e slonsr�7;h-d-�/ and�my�°8nsa Is�i full or a effect. .rf / 1. i Ir�ve.� Y ////� '.S.�r� I It eboffirm that I am exempt from the ContractdirplIcense Law for the following rees0�lf. (Sec. 7031.5.8usiness and Professions Code: Any city or county which requires a permit to construct, "after. Improve, demolish, or repair any structure, prior to 'Its Issuance also requires the applicant for such permit to -rile a signed -statement that he ts.licensed pursuant to Ne provisions of the Contractor's License Law, Chapter :9'Commenctng with Se i 7000) o/ Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for the alleged exemption: Anyviolation o/ Section 7031.5 by any applicant for a permit subjects the applicant to a civil penally of hot more than -five hundred dollars ($500). . L I, as owner of the property, or my employees with wages as their sole compensation, will ' do the work, and the structure is not intended or offered for sale. (Sec. 7044, Bulsness and Professions Code: The Contractor's License Law does'not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the bullding or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or Improve for the purpose of sale.) I'1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code:. The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 0 1 am exempt under Sec. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self' insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company n Copy is filed with the city. ❑ Certified copy Is hereby furnished. CERTIFICATE OF EXEMPTION FROM! WORKERS' COMPENSATION INSURANCE (This section need not be, completed i/ the pennit Is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work. for which this permit is Issued, I shall not employ any pparson in any manner so as to become subject to the Workers' Compensation Laws of Calilornia. Date Owner NOTICE TO APPLICANT., If, offer making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration It work thereunder Is suspended for 180 days. I certify that I have read this application and state that the above information Is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE= FINANCE APPLICATION ONLY y� BUILDING: TYPE"CONST. OCC. GRP. A.P. Numberz-- Legal Description� T L Project Description SED Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition.0, Estimated Valuation ' PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Av Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ' ZONE: BY: Minimum Setback Distances: !f-' Front Setback from Center Line Rear Setback ear Prop. Line Side Stremgei��i Side SetbFINAL DATE Issued by: Validated by: YELLOW = APPLICANT rl ^ vUINT� N�NDEDEPT I PINK = BUILDING DIVISION C A ",V loo 3o/SN3W •aw rasuene �Nnvssmv (9 . 39H S92Z/'03S t//N 710d L/o-ozo y�rl 9Z-FLL LD6/ MJNYM ' a -a w N•R 4•� SL/B/ BW // roy qu/q .77 wa06•B-ld w r, •N www . . n o OL/B/ 9W O/ bN INn c!a/np a7/aA /C 0!//t/wn7 orynS fr y 37747 �— y •c ., // ®� /til ?I /� ®9 // All .. " •` a zi •• •` of Q ®ri o/ Q ®ri —dr,� .� K s of Q � ri of®®r, ro a � O • O\ a fir/ L e® L aW a O ---- Z 69 1� LO 0.9/ r- f9 l® ©9/� m L ©9/ t o w. a © O Ll a © Q Ll t) r a n ®r O al a r ®O B/ n r® OF GZ C e ti oZ ©r Qoa r 8 Ooz a ....� 2 Ozz � $. ®/ Ott ` •` " , Q Ott . " " —Y CHpNOS t r. � 377VJ 7__ (9 . 39H S92Z/'03S t//N 710d L/o-ozo y�rl 9Z-FLL MAY.21.2001 _8_56AM -CDS JRDENG•REOUMTED BY- 4CO TITLE • COMPAW-1. ",a....•._ . J WHEN Rhe,CORDED MAIL TO JIM ?4MKw2IR . P.O.box ISIS7 Preftnt, Cu. 94539 NO. 495 P.3/4 L �J Riaelraa NO. 27014116 -EtO Q a No 17P3esac -mm Aaove mfr uNR FcP R=AM2 AS w � r..' -'ter. a parcel No: 2.07.1-9 DOCUMENTARY TRANSPMTAXIS $29,50 rA4 unlrmlyawmd amu [:3 ary of computed on the full value of the Jnedrw or pmpety coaveyod, or is © computed an the full value ice the value ori aux or socumbmn= txmeining:u dme bf hale, apd FOR A VALUABLE CONSIDEILATION,teceipt of which is hereby at�wk*d, CRRIS ROWEL -TI, a. married man as his sole and separate property, hereby GRANT(8) to JOEN N. MCIMRTE, a ttterried Dian as b6% sole and separate property. the fallowing described real progeny in the County of RTVER9IDO , State of CaWoruW LOT 12, BLOCt Ell or sAN',pA QABMEI xu =T No • 10, ass SHOWN BY MAP ON PISS ADT BOOK is, PACE 74 OF MAPS, RECOPZS OF RIVERSIDE CO=Y, CALIFORNIA ` Dated February 23, 2001 Y�►all sm,e OFmFc- m1 �L UL-.-- uThtiN COUNTYO 4SS• On_Mrt.Lcln_5 �nr�l before Me, nn a Notary Public in and far said County and State, pereenal�ly Appeared , peraonmlll► known to me (or pmv4d to Me pn the belle of 9aiafaclory evidenoal to be the perean(c) whose name(a) Wong subecribea to the within (netftrnleflt'and seknowladSed to nye that the mare In h1sIANOW* autharizt cl Capat;lty(lea), and that by histhetgk0111f sl-Inature(s) an the instrument the pefaon(6), of the entity upon behalf of a +rah the Persons) acted, axecutag the Instrument WITNESS my hand and offiolul eeel. L I,, D �. or..,. ••,,^NOfBiY PJabtiC� 1 fdaWY -ear SON Scit taetto fj, i11ah BEI' j MY oertmJaalra, L?ictns JlOA126� 8 L s ajf w i J . .� I n L�s,�L,�.,,� al 'g-001 na rs of Notary `+ ase my vAmmlealan wGires FOA NOTARY sou. cul STAMf MAIL TAX STATEMENTS r0 PAmY slgowN ON FOLLOWINO UNE; IF NO PARTY SO SHOWN, MAIL. AS DIRECTED ABOVE wMa My. stats & zip eoa eae�o2rattrk r r� Desert Sands Unified School District ,rT 47-950 Dune Palms Road Notice: f La Quinta, CA 92253 Document Cannot Be Duplicated ; 760-771-8515 CERTIFICATE OF COMPLIANCE Date 5/31/01 No. 22070 Owner Name Jack McKenzie Desert"Cove Dev., LLC APN # Jurisdiction La Quinta 173-26-011 Permit # 0105-241 No. 77-570 Street Calle Ensenada Log # City La Quinta zip 92253 Study Area Tract# V10 Lot# 12 Square Footage 1,591 Type of Development Comments ,t> Single Family. Residence No. of Units 1 *Received Cashier's Check.for the amount of $6,523.10. At the present time, the Desert Sands, Unified School District does not collect fees on garages/carports, covered patios/walkways, .residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This, certifies. that school facility fees.imposed pursuant to f Government Code 53080 in the amount of j 2.05 X 1,591 or $ 3,261.55 the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued Fees Paid By CC/ PFF Bank & Trust - Mark Roe Telephone Name on the check By Dr. DorisiWilsonr- Superintendent Fee collected /exempted by Paula Ruiz Payment Received $3,261.55 i Check No. 520999825 - Signature NOTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above wilt begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to -ollect-them on the Distri6f("s)(s').behalf, whichever is earlier. .i irl;:1, Collector: Attach a copy of county or city-"]" -check application form to district copy for all waivers. Embossed Original- Building Dept./ApplicantM; Copy - Applicant/Receipt Copy -Accounting C1 T _ .iINJI�l,,S, J--, .,W" N DESIGN M',10AS, INC. A Condruction Management Company City of La Quinta i Custom flames - Commercial Buildings License #767086 P.O. Box 628 :i Lo Quinfa, CA 92253 TR. (7.60) 771-3593 FAX (760) 771-4093 f -mail: cdi.b,uilders@gfe.net November 28, 2001 C.D.S., Inc. is no longer the General Contractor for the following addresses. Please remove our name as builder on record. If you have any questions please call our office (760) 771-3593. 77-585 Calle Durango 77-570 Calle Ensenada X53=445 -Eisenhower -Dr: , 77-740 Calle Colima Please -send any correspondence to the owner. Desert Cove Development Jack Mckenzie 124 Castlewood Dr. Pleasanton, CA 94566 Cell # (925) 580-7883. �7 . . ........ . . /- i City of La Quinta, Building & Safety Department RESIDENTIAL PLAN CHECK CORRECTION LIST (5a RD - L.►w1� 9% a"3 fvpt- 77 - 740 Cay %mp-t DATE: 4/17/01 ADDRESS: 77-570 Calle Ensenada STATUS: First Review DESCRIPTION: Single Family Dwelling PLAN CHECKED BY: Greg Butler Y^O APPLICANT: Construction Design Systems TELEPHONE NUMBER: (760) 777-7015 PLAN CHECK #: This submittal has been checked for compliance with the 1998 California Building, Mechanical, Electrical, and Plumbing Codes (CBC, CMC, CEC, and CPC, respectively), the City of La Quinta Municipal Code, and applicable portions of California Energy Code. APPLICANT: The following items are being returned to you for correction: 2 sets of plans 2 sets of Energy Calculations BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: 2 sets of corrected olans 2 sets of corrected Energy Calculations 2 sets of Truss Calculations w/ layout plan Correction list and written responses INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Plans and/or Calculations prepared by a licensed Architect or Engineer may not be modified by anyone other than that professional. 3) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 4) Return all red -marked Plans and/or Calculations with your resubmittal. 5) Return this list, your written responses, and all documents listed above with your resubmittal. 6) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by the California Business and Professions , Code §5536. Digital signatures are not acceptable. Resubmittals will not be accepted with signatures missing. 7) Any response that does not conform to the literal requirements of the Code can only be approved by the Building Official. 8) As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 1 of 6 City of La Quinta, Building & Safety Department SECTION A - GENERAL 1) Provide the Project Address on the first sheet of Plans. 2) Note on Plans: `All construction shall comply with the 1998 California Building, Plumbing, Mechanical. and Electrical Codes and all other local codes and ordinances. " (Note exists. Remove notes referencing other Codes.) 3) Note on Plans: "All `or equal' substitutions must be submitted to, and approved by the Building Official prior to installation of the item." SECTION B — PRECISE / SITE PLAN / ZONING 1) Show on Site Plan how lot will drain to the Right -of -Way with a minimum slope of. l%. (CBC Appendix §3315.4) 2) Show on Site Plan the required number of 1-1/2" caliper trees: three on interior lots; five on corner lots. (LQMC §9.50.090.A.10) 3) Show and dimension all proposed concrete flatwork, including air conditioning condenser pads, landings at exterior doors, walkways and driveways. (CBC § 106.3.3) Include Garage pedestrian door. 4) Show location, height, and materials for all existing and proposed walls, fences, and gates. Clearly identify size and extent of all required retaining walls. (LQMC §9.60.030) See Site Plan. 5) Note on Site Plan: "Driveway approach requires a separate permit and inspection from City of La Quinta Public Works Department." SECTION C - ARCHITECTURAL 1) Specify 1 -hour assembly for garage ceilings where garage trusses are perpendicular to and cross the house/garage wall. When ceiling is used as part of assembly, it shall be protected as specified in CBC Table 7-C, Item 21, or as specified in the current edition of the Fire Resistance Design Manual published by Gypsum Association. Provide details and/or notes to describe the method.being proposed. Supporting walls shall be of equal rating. (CBC §302.4, Ex. 3) 2) Provide attic ventilation calculations per CBC 1505.3. (Provide minimum 1/300) Calculate Garage space separately from living area due to occupancy separation. 3) Provide cross ventilation for each separate attic space. Show all required vents in Plan and/or Elevation views. (CBC § 1505.3) Vent Garage separately from living space due to occupancy separation. 4) Provide attic access opening(s) not less than 22" x 30". Access shall be located in a corridor, hallway or other readily accessible location. Thirty -inch minimum unobstructed headroom in the attic space shall be provided at or above the access opening. (CBC §1505.1) Show all locations on Plan. 5) Specify the make, model number, and ICBO Evaluation Report Number (or UL Listing Number) of factory - built fireplaces and/or wood stoves. (CBC § 106.3.3 and 3102.5. 1) ICBO Report #2578 not found. Provide paper copy of current report. 6) Specify exterior cement plaster application (total thickness and number of coats). If a "power wall" system is Residential Plan Check Correction List Page 2 of 6 City of La Quinta, Building & Safety Department proposed, specify ICBO Evaluation Report Number for the specific material and application. (CBC §2508) SECTION D - MECHANICAL 1) This plan set includes two conflicting Mechanical Plans. Remove one plan. Compliance with Energy Calculations will be checked at next submittal. 2) Show on Plans how fireplace installed in Master Bedroom obtains combustion air from outside. (CMC §304.5, Ex. 4) 3) Provide permanent, substantial protection for FAU, water heater, washer and dryer in garage from vehicle impact. (CMC §304.9) . SECTION E - ELECTRICAL 1) Electrical service panel, telephone and television service entrance boxes may not compromise the integrity of Braced Wall Panels. Relocate as necessary. 2) Note on Plans: "Aluminum conductors are permitted only if size 1/0 or larger, and only to feed main or sub - panels. All other current carrying conductors shall be copper." (LQMC §8.03.030) 3) Note on Plans: "Provide at least two 20 -ampere small appliance branch circuits to serve kitchen, breakfast room, and dining room. Such circuits shall have no other outlets." (CEC §210-52(b)(1) through 210- 52(b)(3), 220-4(b)) 4) Note on Plans: "Provide at least one 20 -ampere branch circuit to serve laundry appliances. Such circuit(s) shall have no other outlets." (CEC §210-52(f), 220-4(c)) 5) Note on Plans: "Provide at least one 20 -ampere branch circuit to serve bathroom receptacles. Such circuit(s) shall have no other outlets." (CEC §210-52(d)) 6) Specify GFCI protection for receptacles serving the kitchen countertop. (CEC §210-8(a)(6)) 7) Kitchen and Dining Room Countertop receptacles shall comply with the following (CEC §210-52(c): a) Provide a receptacle outlet at each wall counter space 12 inches or wider. b) Provide receptacle outlets at each wall counter so that no point along the wall line is more than 24 inches, measured horizontally from a receptacle outlet in that space. c) Provide at least one receptacle outlet at each island counter space with a long dimension of 24 inches or greater and a short dimension of 12 inches or greater. d) Provide at least one receptacle outlet at each peninsular counter space with a long dimension of 24" or greater and a short dimension of 12" or greater. A peninsular countertop is measured from the connecting edge. Informational item: Receptacle outlets shall be installed not more than 18 inches above the countertop. Receptacle outlets rendered not readily accessible by appliances fastened in place or appliances occupying dedicated space shall not be considered as these required outlets. 8) Provide in every kitchen, family room, dining room, living room, parlor, library, den, sun room, bedroom, recreation room, or similar room or area of dwelling units, receptacle outlets so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width and the wall space occupied by fixed panels in exterior walls, but excluding Residential Plan Check Correction List Page 3 of 6 City of La Quinta, Building & Safety Department sliding panels in exterior walls. The wall space afforded by fixed room dividers, such as freestanding bar - type counters or railings, shall be included in the 6 -foot measurement. (CEC §210-52(a)) See Plan for locations not meeting this requirement. Informational item: As used in this section, a "wall space" shall be considered a wall unbroken along the floor line by doorways, fireplaces, and similar openings. Each wall space 2 feet or more in width shall be treated individually and separately from other wall spaces within the room. A wall space shall be permitted to include two or more walls of a room (around corners) where unbroken at the floor line. Receptacle outlets shall, insofar as practicable, be spaced equal distances apart. Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located within 18 inches of the wall. The receptacle outlets required by this section shall be in addition to any receptacle that is part of any lighting fixture or appliance, located within cabinets or cupboards, or located over 5-1/2 feet above the floor. Provide at least one wall switch -controlled lighting outlet in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at the exterior side of outdoor entrances or exits. (CEC §210-70(a)) See Plan for locations not in compliance. SECTION F - PLUMBING 1) Provide an access panel (12" x 12" minimum) to bathtub trap connection. (CPC §405.2) SECTION G — ENERGY EFFICIENCY Due to conflicts in Mechanical Plans, a comprehensive review will be performed at next submittal. 1). Water heater callout on plans (75 gal) conflicts with Energy Calculations (50 gal). Reconcile. 2) Provide completed and signed form CF -1R energy compliance statement. GLS to sign calculations. 3) Provide a Form 3R for exterior wall assembly used in Energy Calculations. 4) Specify in Section drawings the wall and ceiling insulation specified in Energy Calculations. Demonstrate how R-21 is achieved in exterior walls. Areas and orientations of glazing on Plans do not match those in Energy Calculations. Reconcile Plans and Calculations. See Floor Plan for area(s) not in compliance. SECTION H - CONVENTIONAL LIGHT -FRAME CONSTRUCTION 1) This structure may qualify to be constructed under the provisions of CBC §2320 for conventional light -frame construction. However, insufficient information has been provided from which to plan check under these provisions. Provide on Framing and Foundation Plans all elements required by CBC §2320. Alternatively, provide a design by a licensed architect or engineer in accordance with CBC § 1605, including vertical and lateral calculations. A comprehensive structural review will be performed at the next submittal. (CBC §2320.1, 2320.5.4) Show all exterior and interior Braced Wall Lines and Panels. 2) Provide Truss Calculations, with Layout Plan, for this project. (CBC §106.3.3) 3) Identify on Framing and Foundation Plans the location, extent, and materials for all exterior braced wall lines. (CBC §2320.5.1) See Plans for area(s) not in compliance. Residential Plan Check Correction List Page 4 of 6 City of La Quinta, Building & Safety Department Informational Item: Spacing of braced wall lines shall not exceed 25 feet'on center in both the longitudinal and transverse directions in each story. (CBC §2320.5.1) 4) Identify on Framing and Foundation Plans the location, extent, and materials for all interior braced wall lines. (CBC §2320.5.1) See Plans for area(s) not in compliance. Informational Item: Spacing of braced wall lines shall not exceed 25 feet on center in both the longitudinal and transverse directions in each story. In one- and two-story Group R, Division 3 buildings, interior braced wall line spacing may be increased to not more than 34 feet on center in order to accommodate one single room per dwelling unit not exceeding 900 square feet. (CBC §2320.5.1 and Exception) 5) Show on Foundation and Framing Plans the location, width, materials used, nail size and spacing, and panel spacing for all Braced Wall Panels. (CBC §2320.11.3) Informational Item: Braced Wall Panels shall be in line or offset from each other by not more than 4 feet. Braced Wall Panels shall be placed at each end of braced wall lines and not more than 25 feet on center. Braced Wall Panels shall start at not more than 8 feet from each end of a braced wall line. Top plates shall be connected to the framing above per CBC Table 23-11-B-1. Sills shall be bolted to the foundation per CBC § 1806.6. (CBC §2320.11.3) 6) Provide notes and/or details for construction of Braced Wall Panels in accordance with CBC §2320.11.3. See notes at Foundation Plan for specific corrections. 7) Show on Foundation and Framing Plans the location, width, materials used, nail size and spacing, and panel spacing for all Alternate Braced Wall Panels. (CBC §2320.11.4) Informational Item: Alternate Braced Wall Panels in one-story buildings shall have a length of not less than 2 feet 8 inches and a height of not more than 10 feet. (CBC §2320.11.4) 8) Provide notes and/or details for construction of Alternate Braced Wall Panels in accordance with CBC §2320.11.4. See notes at Foundation Plan for specific corrections. 9) Specify on Framing Plan the size, species, and grade of lumber for all headers. (CBC §2320.11.6) Show all headers. Verify that all headers are in their proper location. 10) Specify on the Plans the location of any 2 x 6 walls necessary to accommodate plumbing or other piping. (CBC §2320.11.9, 2320.11.10) Identify 2 x 6 wall at Bath #2. 11) Specify on Framing Plan the material, grade, and nailing requirements for roof sheathing in accordance with Tables 23 -H -E-1 and 23 -II -E-2 for wood structural panels, and 23 -II -D-1 and 23 -II -D-2 for lumber. (CBC §2320.12.9) 12) See additional correction notes on Sheet D.1. SECTION I - STRUCTURAL 1) No corrections apply. SECTION J — SOIL / FOUNDATION 1) No corrections apply. Residential Plan Check Correction List Page 5 of 6 City of La Quinta, Building & Safety Department SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide a copy of the Grant Deed for this property, verifying the legal description and Assessor's Parcel Number. END CORRECTION LIST ;f Residential Plan Check Correction List Page 6 of 6