Loading...
05-1711 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 05-00001711 77655 CALLE ENSENADA 773-294-001-2 -000000- REMODEL - RESIDENTIAL COVE RESIDENTIAL 30821 Architect or Tav/ 4,Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT D � � SEP 16 2005 CrIY C 1IS rN rN d LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: I License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason ISec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: f�\_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: CONSTRUCTION LENDING AGENCY , I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPER\1IT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/16/05 Owner: MONTALVO PEDROI&C,-47e tIC 77- 6-Z7 trnrrrtanrrta r> 0000a L4 Other CR Other struct info . . . . . C 922'S'3 Contractor: Owner DITION 2001 CBC WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier 2.00 Policy Number - - - - -- - - - - - - - -- I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor s all forthwith comply' h those rovisi s. � Date: 9 Applicant: WARNING: FAILURE TO SECUENSA110N COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authoriz representatives of this cou ty to enter upon the above-mentioned p�inspectiooses. Date Signature (Applicant or Agentl. Application Number . . . . . 05-00001711 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 291.00 Plan Check Fee 189.15 Issue Date Valuation . . . . 30821 Expiration Date 3/15/06 Qty Unit Charge Per Extension BASE FEE 252.00 6.00 ----------------------------------------=----------------------------------- 6.500.0 THOU BLDG 25,001-50,000 39.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 34.23 Plan Check Fee 8.56 Issue Date . . Valuation . . . . 0 Expiration Date 3/15/06 Qty Unit Charge Per Extension BASE FEE 15.00 443.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 15.51 186.00 ---------------------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 3..72 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 39.50 Plan Check Fee 9.88 Issue Date . . . Valuation . . . . 0 Expiration Date 3/15/06 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH VENT FAN 6.50 Permit PLUMBING Additional desc . Permit Fee . . . . 36.00 Plan Check Fee 9.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/15/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 2.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 LQPE%NIIT Application Number . . . . . 05-00001711 ----------------------------------------------=----------------------------- Special Notesand Comments ADDITION OF 443 SQ.FT. BEDROOMS, 186 GARAGE AND 138 SQ. FT. PATIO.KITCHEN REMODEL.May 9, 2005 11:11:17 AM JJOHNSON - ----------------------- Other Fees . . . -------------------- . . . . . . ENERGY ------ REVIEW ------------- FEE ------------- 18.92 STRONG MOTION (SMI) - RES 3.08 Fee summary ----------------- Charged Paid --------=----------- ---------- Credited ---------- Due Permit Fee Total 400.73 .00 .00 400.73 Plan Check Total 216.59 .00 .00 216.59 Other Fee Total 22.00 .00 .00 22.00 Grand Total 639.32 .00 .00 639.32 LQPERIIIT �Jr 4. Bin # City of La Quinta Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # �1 Project Address: rl e 4 n q,,:) Owner's Name: £MnAztm A. P. Number: 'Address: `1' 7 - �6S CQJI e 1 rWNAd 6-- y� Legal Description: City, ST, Zip: 1 d- (i'z 5— Contractor: Telephone. � ....::..:....... ........::.:.:.:::::::..: d Address:roject-Desc p n: 1�V1 01 City, ST, Zip:r-6o yy� 5 a -A VW It) aii . Telephone: e P L S � D r State Lie. # : City Lie. Arch., Engr., Designer: •� U GI oSc A t) ry. Address: J City, ST, Zip: 11 OQ Telephone: Construction e. Occu a cN - P one): #: DemoState Lie. roJectt}Pe� circle Ne Alter Name of Contact Person: Sq. Ft # Stories: # Units: Telephone # of Contact Pers Estimated Value of Project: nn: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Re 'd Ree'd TRACKING PERMIT PEES Plan Sets Plan Ch submitted'�14 Item Amount Structural talcs. ' a Reviewed, re y for corrections Q Plan Check Deposit Truss Calcs. Called Con ct Person Plan Check Balance Title 24 tales. 2 A Plans picked up Construction Flood plain plan Plans resubmitted ! 1 Mechanical Grading plan 2"d Review, read) r correction /issue ( Q„j Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up �!(g S.I.I. II.O.A. Approval Plans resubmitted Grading IN IIOUSE:- 7rd eview, ready for correcti s/issue Developer Impact Fee Planning Approval Called Co tact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 51? N(5, B It � c -"i CA 1W P . CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road < BERMUDA DUNES Date 9/16/05 La Quinta, CA 92253 RAN MIRAGErZ INDIAN AN WELLS DESERT No. 27658 d�PALM LAQUINTA (760) 771-8515 ZP�OINDIO Owner Montalvo APN # 773-294-001 Address 77-655 Calle Ensenada Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units Lot # No. Street S.F. Unit 1 77655 Calle Ensenada 443 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 443 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt-Montalvo Check No. Name on the check Telephone By Dr. Doris Wilson Superintendent • , Fee collected /exeMRted by Patricia Barbuzza Signature Funding Exempt Payment Recd '-1$0-00 , Over/Undef; - NOTICE: Pursuant to Government Code Section 0(d)(1), this will serve to notify you that the 90•day approval period in which you may protest the fees o r other payment identified above Will begin to run ffom the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the Districts) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy -Applicant/Receipt Copy -Accounting A . P . N .: 773-2�994-0%0�1( Order No. DOC a 2005-0094220 02/02/2006 08:00A Fee:27.00 Page 1 of i Recorded in Official Records County of Riverside Larry -W. Ward Assessor, County Clerk 8 Recorder 111111111111111111111111111111111111111111111111111111 M S — U Recording Requested By. SIZE First American Title Company POOR RECORDING REQUESTED BY SMF AND WHEN RECORDED MAIL TO: PEDRO MONTALVO BEATRICE A. MONTALVO 77655 CALLS ENSENADA LA QUINTA, CA 92253 A . P . N .: 773-2�994-0%0�1( Order No. DOC a 2005-0094220 02/02/2006 08:00A Fee:27.00 Page 1 of i Recorded in Official Records County of Riverside Larry -W. Ward Assessor, County Clerk 8 Recorder 111111111111111111111111111111111111111111111111111111 M S — U PAGE SIZE OA POOR NOCOR SMF Ntlsc. i f f A R L COPY I LONG I REFUND NCHG I EXAM GRANT DEED THE UNDERSIGNED GRANTOR(s) DECLARE(s) THAT DOCUMENTARY TRANSFER TAX IS: COUNTY $ 0 - computed on full value of property conveyed, or [[ computed on full value less valve of liens or encumbrances. remaining at time of sale, unincorporated area; [ )- City of LA OUINTA , and - FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, PEDRO MONTALVO hereby GRANT(s) to PEDRO MONTALVO and BEATRICE A.. MONTALVO, Husband and Wife as Joint Tenants the following described property in the City of LA QUINTA, County of Riverside State of California; Lot 2 Block 87 of Tract , in the City of LA QUINTA, County of Riverside, as per map recorded in Book 18, Page(s) 70, in the Office of the County Recorder of said County. PEDRO MONTALVO Document Date: January 28, 2005 STATE OF ' L-A _ "\jM AS CO _ TY OF. Q L_ _: ._, . ) -. before me, �� i1� , a Notary Public, personally appea I niin-f-rA.l Ilt3 personally-knowa to inc!(or proved to me ori the WAS of satisfactory evidence) to be the perso whose name afare subscribed to the within instrument and acknowledged to me th�/shehhey executed the same iYls&"Ah jr authorized capacity and that bh' herAlwir signature(df on the instrument the person or the entity upon behalf of which the personacted, executed the instrument. _ WITNESS my hand and official seal. �l,, IN�� ;1 � This area for official notarial seal. C1MT141A A LONA Commbd= # 1412969 Notaly Public - Confomta RMWde County My Comm. Bow Apr 22, 2007Rp OWNER/BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/ Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If you are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations including State and Federal income tax withholding, federal social security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Adminstration). For more specific information about your obligations under Stare Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/ Builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed 'by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Very truly yours, CITY OF LA QUINTA DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quinta, CA 92253 (760)777-7012 0) 7 7-7011 ER' S SIGNATURE / D E Lyle PROPERTY ADDRESS PERMIT NUMBER(s) TITLE 24 REPORT Title 24 Report for: PEDRO & BEATRICE MONTALVO 77655 CALLE ENSENADA LA Q U I NTA, CA 92253 Project Designer: EDUARDO AYALA 50701 WASHINGTON ST APT. # 811 LA QUINTA, CA 92253 (760) 564-9235 Report Prepared By: S. L. 0. Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: LQ042205 User Number: 5732 Job Number: CITY OF (meq QUINTA LQ042205 BUILDING & SAFETY DEPT, �_... APPROVED FOR CONSTRU TION Date: DATE BY 9/2/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: LQ042205 User Number: 5732 I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 Form ENV -3 Proposed Construction Assembly 15 HVAC System Heating and Cooling Loads Summary 17 EnergyPro 3.1 By Energysoft Job Number: LQ042205 User Number: 5732 \J Certificate of Compliance: Residential (Part 1 of 2) CF -1 R PEDRO & BEATRICE MONTALVO 9/2/2005 Project Title Date 77655 CALLE ENSENADA LA QUINTA Project Address Building Permit # Santiago Lopez-Ocampo (760) 485-8927 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,838 ft2 Average Ceiling Height: 8.0 ft Total Conditioned Slab Area: 1,838 ft2 Building Type: Frame Type (check one or more) Location/Comments (attic, garage, typical, etc.) © Single Family Detached ❑ Addition ❑ Single Family Attached X❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall Default Roof 1978 to Present Wood 0.047 Exterior Roof Default Wall 1978-1991 Wood 0.098 Exterior Wall Solid Wood Door None 0.387 Exterior Door FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (East) 16.0 0.65 0.40 Bug Screen X❑ ❑ ❑ X❑ Front (North) 55.4 0.65 0.40 Buq ScreenX❑ ❑ ❑ X❑ Left (East) 20.0 0.65 0.40 Bug Screen ❑ X❑ ❑X❑ Front (North) 48.0 1.28 0.80 Bug Screen ❑ X❑ ❑ Q Rear (South) 12.0 0.65 0.40 Bug Screen ❑ Q ❑ Q Rear (South) 40.0 0.65 0.40 Bug Screen 0 ❑ ❑ 0 Rear (South) 6.0 1.28 0.80 Bug Screen ❑ Q ❑ Q Right(West) 32.0 1.28 0.80 Bug Screen ❑ Q ❑ Q ❑ ❑ ❑ ❑ ❑❑ ❑❑ 1:1 El El F-1 El El El El Run Initiation Time: 09/02/05 18:19:59 Run Code: 1125710399 Ener Pro 3.1 By Ener Soft User Number: 5732 Job Number: L0042205 Pa e:3 of 18 Certificate of Compliance: Residential Part 2 of 2 CF -1 R PEDRO & BEATRICE MONTALVO 9/2/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronlc or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC System (New) rentral Furnace 92% AFUE Ducts in Attic 42 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Setback HVAC System (New) Split Air Conditioner 1 07 SEER Ducts_ in Attic 42 Setback HVAC System WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Storage Elec. Standard 1— 15-358 �0_ 0.89 n/a n/a PRODUCTS P JF -50T 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT . This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: S.L.O. Title/Firm: EDUARDO AYALA Title/Firm: Santiago Lopez-Ocampo Address: 50701 WASHINGTON ST APT. # 811 Address: P.O. Box 1018 LA QUINTA, CA 92253 La Quinta, CA 92247 Telephone: (760) 564-9235 Telephone: (760) 485-8927 Lic. #: Awe (signature (da ) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Time: 09/02/05 1819*59 Run Codes 1125710399 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 PageA of 18 Certificate of Compliance: Residential (Addendum) CF -1 R PEDRO & BEATRICE MONTALVO 9/2/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 454 sgft Exposed Slab Floor, 3.50" thick at Addition HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1384 sgft Exposed Slab Floor, 3.50" thick at Existing HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC System (New)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 09/02/05 18:19:59 Run Code: 1125710399 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page:5 of 18 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures X 1150(a): Minimum R-19 ceiling insulation. E] §150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑§150(c): X not apply to exterior mass walls). E§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ❑X § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑X §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page:6 of 18 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FV `§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. XI§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page:7 of 18 Computer Method Summary ■ ;. . (Part 1 of 3) C -2R PFnRO, BEATRICE Project Title MONTAI V 912/2005 Date rAI I F ENSENADA LA OUINTA _7_7655 Project Address Building Permit # Santiaggo I ooeZ-OcampO a (760) 485-8927 Documen tion Author Telephone plan Check/Date r.nmauter Performance Compliance Method (Package or Computer) 15 1 Field Check/Date Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Exist! ng+Addition Budget Adjustment Space Heating 4.25 5.25 -1.00 Ratio F: 1384 / 1838 = 0.753 Space Cooling 39.82 46.72 -6.90 Budget Adj: 0.753 X ( 94.25 - 64.23) = 22.61 Domestic Hot Water 13.76 24.03 -10.27 The budget shown to the left has been increased using Totals 22.61+ 57.83 = 80.44 76.00 4.44 this Budget Adjustment based upon Existing building information shown on the C -2R which follows this form. better than Standard: 5.5% Total Conditioned Floor Area: 1,838 ft2 Floor Construction Type: ❑ Raised Floor X❑ Slab Floor Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 12.5% Number of Dwelling Units: 1.00 Total Conditioned Volume: 14,704 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 1,838 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC Vctem (Npw) 454 3 f) 9.9; SPthark n/a HVAC _ stem 1384 11 072 0.75 Conditioned Sethark n/a OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Rnnf 454 0.024 —Q is Wall — 97 0 088 g0 gn Wall 39 0 088 a An Wall 71 0.088 _90 90 Wall 171 0.088 180 90 Roof 1x384 0 047 _0 1 A Wall 335 0.098 0 qQ nnnr 20 0.387 _0 go Wall 111 0.098 go _9fl_ poor 18 0.387 qf) _An Wall 113 0.098 180 gQ Wall 24 0.098 90 90 Wall 155 0 098 180 _9.Q wall 308 0.098 270 gn Door 18 0 387 270 9f) Solar Gains Y / N Form 3 Reference /: ■ ;. . a e Location / Comments EneravPro 3.1 By EnerovSoft User Number: 5732 Job Number: LQ042205 Page:8 of 18 1 Computer Method Summary (Part 2 of 3) C -2R PEDRO & BEATRICE MONTALVO 9/2/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments J_ Window Left -(Fast) 16.0 0 650 0 .40 90 gn DEFALT DBL PANE U Additinn 2 Window Front (North) 40.0 0.650 0.40 0 90 DEFAULT DBL PANE Addition 3 Window Left (East) 20.0 0.650 0.40 90 90 DEFAULT DBL PANE Addition 4 Window Front (North) 16.0 1.280 0.80 0 90 Single Metal Clear Default Existing 5 Window Front (North) 16.0 1.280 0.80 0 90 Single Metal Clear Default Existing 6 Window Front (North) 16.0 1.280 0.80 0 90 Single Metal Clear Default Existing L Window Front (North) 7.7 0.650 0.40 0 90 DEFAULT DBL PANE Existing 8 Window Front (North) 7.7 0.650 0.40 0 90 DEFAULT DBL PANE Existing 6 Window Rear (South) 12.0 0.650 0.40 180 90 DEFAULT DBL PANE Existing 1Q Window Rear (South) 40.0 0.650 0.40 180 90 DEFAULT DBL PANE Existing 1 Window Rear (South) 6.0 1.280 0.80 180 90 Single Metal Clear Default Existing 12 Window Right (West) 12.0 1.280 0.80 270 90 Single Metal Clear Default Existing _U Window Right (Wes) 12.0 1.280 0.80 270 90 Single Metal Clear Default Existing 14 Window Right (West) 4.0 1.280 0.80 270 90 Single Metal Clear Default Existing 15 Window Right (West) 4.0 1.280 0.80 270 90 Single Metal Clear Default Existing INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 4.0 10.2 0.1 2.0 2.0 2 Bug Screen 0.76 6.7 6.0 14.0 0.1 0.0 0.0 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 6.7 1.2 3.0 0.1 2.0 2.0 8 Bug Screen 0.76 6.7 1.2 3.0 0.1 2.0 2.0 9 Bug Screen 0.76 10 Bug Screen 0.76 6.7 6.0 5.7 0.1 2.0 2.0 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 Run Initiation Time: 09/02/05 18:19:59 Run Code: 1125710399 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page:9 of 18 Computer Method Summary (Part 3 of 3) C -2R PEDRO & BEATRICE MONTALVO 9/2/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight 454 -3M 9R 0 98 n/a _n Addition / Slah on Grade Concrete, Heavyweight 1.384 3_50 28 0.98 n/a 0 Existing / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 55 0.76 0.0 _Q Addition Slab Perimeter 204 0.76 0.0 0 Existing HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 8Q%AFUE Ducts in Attic 4.2 Setback HVAC System (New) Central Furnace 92% AFUE Ducts in Attic 4.2 Setback HVAC System Pipe Hydronic Piping Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System (New) Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH WATER PRODUCTS Storage Elec. Standard 1 15,358 50 0.89 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 09/02/05 18:19:59 Run Code: 1125710399 EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page:10 of 18 Computer Method Summary (Addendum) 2-2R PEDRO & BEATRICE MONTALVO 9/2/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies cased on the aaequacy of the special jusnfication ana aocumentation suomittea. Plan Field HIGH MASS Desiqn(see C -2R) - Verify Thermal Mass: 454 sqft Exposed Slab Floor, 3.50" thick at Addition HIGH MASS Desiqn(see C -2R) - Verify Thermal Mass: 1384 sqft Exposed Slab Floor, 3.50" thick at Existing HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field The HVAC System "HVAC System (New)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page: 11 of 18 1 Computer Method Summary (Part 1 of 3) C -2R PFDRO R 13FATRICF MQWAI VQ Project Title 9/2/2005 Date 7765,5 CAI I F ENSENADA I A QUINTA M EWRIn. Mr. TV Ellie] Project Address Building Permit # Santiago Lopez-Oramno (760) 485-8927 Documen tion Author —� Telephone Plan Check/Date Camnuter Performance Compliance Method (Package or Computer) 15 Climate Zone Field Check/Date Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.37 5.75 -1.38 Space Cooling 43.18 60.33 -17.15 Domestic Hot Water 16.68 28.18 -11.50 Totals 64.23 94.25 -30.02 Total Conditioned Floor Area: 1,384 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Total Fenestration Area: 11.5% Number of Dwelling Units: 1.00 Total Conditioned Volume: 11,072 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 1,384 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC ';Vtpm 1 384 11 n72 1 Wn rnnriitinnPrl SPthnnk n/a OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Boot 1,384 0.047 _0 18_ Wall 350 n nab 0 _ 4n Dnnr 20 n_387 0 At) Wall 102 0.098 90 _9Q Dnnr 18 0.387 go � 90 Wall 240 n o98 180 -9.0 Wall g0 0.098 90 _9r) nnnr 18 0.387 go _ 90 Wall 23 0 048 _l1 _9.0_ W:41L_ 83 n 098 _9Q _gp r)nnr 13 0.387 90 _90 Wall 155 0.098 180 _90 wall 308 n 098 97n _ go noor 18 0.387 270 X3.0_ Solar Gains Y / N Form 3 Reference 18:1 Location / Comments EneravPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page: 12 of 18 1 M EWRIn. Mr. TV Ellie] RI■ ......... 18:1 Location / Comments EneravPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page: 12 of 18 1 Comauter Method Summary (Part 2 of 3) C -2R PEDRO & BEATRICE MONTALVO 9/2/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Tvpe Area Factor SHGC Azm. Tilt Comments J_ Window Front ort 16 0 1 280 n 8n n An Single Metal Clear Default Fxaqtbnq 2 Window Front (North) 16.0 1.280 0.80 0 .90 Single Metal Clear Default Existing 3 Window Front (North) 16.0 1.280 0.80 0 90 Single Metal Clear Default Existing 4 Window Left (East) 9.0 1.280 0.80 90 90 Single Metal Clear Default Existing 5 Window Rear (South) 40.0 0.650 0.40 180 90 DEFAULT DBL PANE Existing 6 Window Left (East) 24.0 1.280 0.80 90 90 Single Metal Clear Default Existing L Window Rear (South) 6.0 1.280 0.80 180 90 Single Metal Clear Default Existing 8 Window Right (West) 12.0 1.280 0.80 270 90 Single Metal Clear Default Existing 6 Window Right (ZLesU 12.0 1.280 0.80 270 90 $finale Metal Clear Default Existing 1Q Window Right est) 4.0 1.280 0.80 270 90 male Metal Clear Default Existing 11 Window Right (West) 4.0 1.280 0.80 270 90 . inale Metal Clear Default Existing INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 4.0 2.8 0.1 2.0 2.0 2 Bug Screen 0.76 4.0 4.0 2.8 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 4.0 2.8 0.1 2.0 2.0 4 Bug Screen 0.76 3.0 4.0 33.4 0.1 2.0 2.0 5 Bug Screen 0.76 6.7 6.0 5.7 0.1 2.0 2.0 6 Bug Screen 0.76 3.0 4.0 5.8 01 2- 20 7 Bug Screen 0.76 8 Bug Screen 0.76 3.0 4.0 2.8 0.1 2.0 2.0 9 Bug Screen 0.76 3.0 4.0 2.8 0.1 2.0 2.0 10 Bug Screen 0.76 2.0 2.0 2.8 0.1 2.0 2.0 Ti Bug Screen 0.76 2.0 2.0 2.8 0.1 2.0 2.0 EneravPro 3.1 8v EneravSoft User Number: 5732 Job Number: LQ042205 Page:13 of 18 1 Computer Method Summary (Part 3 of"3) C -2R PEDRO_ & BEATRICE MONTALVO 9/2/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (so (in.) Cap. Inside Location Cond. Form 3 Reference R -Val. Comments Concrete He_ayweight 1 384 3 50 7A n as n/a _n Exislirig / Slah on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 204 0.76 0"0 0 Existing HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 92%AFUE Ducts in Attic 4.2 Setback HVAC System Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH WATER PRODUCTS Storage Elec. Standard 1 15.358 50 0.89 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. PROPOSED CONSTRUCTION ASSEMBLY ENV -3 (PROJECT NAME DATE PEDRO & BEATRICE MONTALVO 9/2/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asphalt Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 ASSEMBLY NAME IDefault Roof 1978 to Present Insulation, Mineral Fiber, R-11 7 Gypsum or Plaster Board 8 0.14 ASSEMBLY Floor 0.88 INSIDE SURFACE AIR FILM 0.610 21.99 TYPE (check one) Wall W LU W X Ceiling I Roof H FRAMING MATERIAL Wood p Z FRAMING % % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asphalt Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-8 6 Insulation, Mineral Fiber, R-11 7 Gypsum or Plaster Board 8 0.14 9 0.02 0.88 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.4401 0.440 0.060 0.060 0.620 0.620 0.800 0.800 7.8401 7.840 11.000 3.465 0.450 0.450 0.14 0.17 0.02 0.88 0. 101 0.610 21.99 14.45 Kc KT 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0455 0.93 ] 1.46 0.30 0.44 0.06 0.35 0.02 1.42 0.29 0.41 0.03 0.20 0.01 0.14 0.17 0.02 0.88 0.35 0.31 2.08 0.26 0.54 6. 11 TOTAL HC 1 7 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0455 0.93 ] + F -,X 0.06921 x E 0.07 1 I Rc 1 - (Fr% 1 100) 11 Rf Fr% /100 ASSEMBLY U -VALUE I EnerovPro 3.1 By EnerovSoft User Number: 5732 Job Number: LQ042205 Page:15 of 18 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE PEDRO & BEATRICE MONTALVO I 9/2/2005 COMPONENT DESCRIPTION DESCRIPTION \MING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-11 4 Gypsum or Plaster Board 5 ASSEMBLY NAME IDefault Wall 1978-1991 0.62 7 0.26 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 12.53 TYPE (check one) X Wall W W Ceiling /Roof yFRAMING MATERIAL Wood p FRAMING % 15% Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTAI R -VALUE DESCRIPTION \MING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-11 4 Gypsum or Plaster Board 5 1.68 6 0.62 7 0.26 8 9 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE THICK- NESS (in.) \MING ❑ ❑ ❑X ❑ El El El El 0.170 0.875 0.010 3.500 0.500 11.000 3.465 0.450 0.450 1.68 0.37 SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.0601 0.060 11.000 3.465 0.450 0.450 1.68 0.37 0.62 2.08 0.26 0.54 0.680 0.680 12.53 5.00 Kc KT *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0798 0.85 ] 8.46 0.20 1.69 0.06 0.35 0.02 1.68 0.37 0.62 2.08 0.26 0.54 12.31 TOTAL HC 2 9 *NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0798 0.85 ] + F -1X 0.20001 X L 0.15 1 / Rc 1 - (Fr-/. /100) 1 / Rf Fr% 1100 ASSEMBLY U -VALUE I EneravPro 3.1 By EnerovSoft User Number: 5732 Job Number: L0042205 Page: 16 of 18 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE PEDRO & BEATRICE MONTALVO 9/2/2005 SYSTEM NAME FLOOR AREA HVAC System New 454 Number of Systems 1 Heating System Output per System 32,000 Total Output (Btuh) 32,000 Output (Stuh/sqft) 70.5 Cooling System Output per System 35,200 Total Output (Btuh) 35,200 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 77.5 Total Output (sgft/Ton) 154.8 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 2.64 Airflow (cfm/Ton) 409.1 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblal Latent CFM I Sensible 252 4,659 0 252 6,573 0 233 329 0 0 0 0 0 0 0 0 0 233 329 5.1 0 7 230 York H4DH036/P4HUA12LO32 U&H 22,637 7,335 32,000 Total Adjusted System Output22,637 7,335 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.7 of 69.7 of 94.8 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 94.5 of 1200 cfm ROOMS 70.0 of 69.7 of 1% Return Air Ducts � 111.0 177.6 OF 74.2 / 62.0 OF 74.2 / 62.0 OF 56.5 / 55.5 OF Outside Air O 0 cfm Supply Fan Cooling Coil 1200 cfm 74.2/62.0 of Time of Cool �% Return Air Ducts "I Supply Air Ducts 56.6! 55.5 of 50.8% R.H. ROOMS 74.0 / 61.9 of EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: L0042205 Page:17 of 18 [HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE PEDRO & BEATRICE MONTALVO 9/2/2005 SYSTEM NAME FLOOR AREA HVAC System 1,384 Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 40.5 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 25.3 Total Output (sgft/Ton) 474.5 Air System CFM per System 1,300 Airflow (cfm) 1,300 Airflow (cfmisgft) 0.94 Airflow (cfm/Ton) 445.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,240 17,048 0 587 24,176 0 852 1,209 0 0 0 0 0 0 0 0 0 852 1,209 18,753 1 01 BDP CO. 563AN036-A 19,583 11,463 Total Adjusted System Output 18,583 11,463 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 26.0°F 69.1°F 69.10F ■ 109.6°F Outside Air 0 cfm Supply Fan Heating Coil 1300 cfm 69.1 OF NG h Return Air Ducts "I 11.0/77.6°F _ 74.6164.5°74.6/64.6°F . 60.5/59.7°F Outside Air 0 cfm 74.6/64.5 °F Supply Fan Cooling Coil 1300 cfm Return Air Ducts 26 593 56,000 56,000 Jan 12 am Supply Air Ducts 108.7 OF ROOMS 70.0 OF Supply Air Ducts 61.1 / 59.9 of 59.6% R.H. ROOMS 74.0 / 64.3 OF EnergyPro 3.1 By EnergySoft User Number: 5732 Job Number: LQ042205 Page: 18 of 18 1