BRES2015-0223Applicant:
DEPAZZA, DENNIS & LEANN
43254 CALLE ESPADA
LA QUINTA, CA 92253
DO Q
AUG 20 2015
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
-.heyr she did not build or improve for the purpose of sale.).
( 1, as owner of the property, am exclusively contracting with licensed contractors
to Wristruct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. P.C. or this reason
Date: C) Own
CONSTRUCTION LENDING A CY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). -
Lender's
Lender's Add
Contractor:
DEPAZZA, DENNIS & LEANN
43254 CALLE ESPADA
LA QUINTA, CA 92253
(541)912-7051
LIC. No.:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree Oat if I should become subject to the
workers' compensation provisions of Sect n 37 of the La shall forthwith
comply with tho e prgvpns.
Date: S Applican • /
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each.agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
.I agree to comply with all city and county ordinances an laws relating to building
construction, and hereby authorize representatives o his city o enter up above•
mention d prop rty for -inspection -purposes.
Date: Signature (Applicant or Ag t
4664P
VOICE (760) 777-7125
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA
92
FAX (760) 777-7011253
COMMUNITY DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 8/20/2015
Application Number:
BRES2015-0223
Owner:
Property Address:
43524 CALLE ESPADA
DEPAZZA, DENNIS & LEANN_
APN:
609580012
43254 CALLE ESPADA
Application Description:
ESPLANADE / DE PAZZA / CONVERT 3RD GARAGE PARKING TO LIVING
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
$3,500.00
Applicant:
DEPAZZA, DENNIS & LEANN
43254 CALLE ESPADA
LA QUINTA, CA 92253
DO Q
AUG 20 2015
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
-.heyr she did not build or improve for the purpose of sale.).
( 1, as owner of the property, am exclusively contracting with licensed contractors
to Wristruct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. P.C. or this reason
Date: C) Own
CONSTRUCTION LENDING A CY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). -
Lender's
Lender's Add
Contractor:
DEPAZZA, DENNIS & LEANN
43254 CALLE ESPADA
LA QUINTA, CA 92253
(541)912-7051
LIC. No.:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree Oat if I should become subject to the
workers' compensation provisions of Sect n 37 of the La shall forthwith
comply with tho e prgvpns.
Date: S Applican • /
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each.agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
.I agree to comply with all city and county ordinances an laws relating to building
construction, and hereby authorize representatives o his city o enter up above•
mention d prop rty for -inspection -purposes.
Date: Signature (Applicant or Ag t
Total Paid for REMODEL: $Z.23.3
gmy
DESCRIPTION Q PAIDPAIDMATE:
0 s
SSAS SB1473 FEE 01-0000-20306 $too, $1.00 8/20/15
-TO
ECI(i-44M
BY
TMAID,13,Y
VLTD
g'q -
g 19- MAN
DEPAZZA, DENNIS & LEANN.: CHECK R8611 1450 'PJU
Total Paid for BUILDINGSTANDARDS ADMINISTRATION BSA :$i.do $1'00
00
�g
g
PAID `i�YAID'.i
IKKACCOWNT
MM74_1AMOUNT
n
E`�% NMA
RESIDENTIAL, FIRST 1,000SF
101-0000-.42403
-0
$145.03
$145.03,
8/26/15
"'111, 011-1
PAID BY:N,
20
0 N
4W
RECEIPT 'iymlll
117121
40 =_R_ .001
e
DEPAZZA, DENNIS.&,LIEANN
CHECK
R86,11
1450'
PJU
b EEOUNT45,i,
` 5 HE
hyR
rQTV
`AMOUNT
DI '-z�`T
�PAIDZATE.l
I
RESIDENTIAL, FIRST.1,000SF, PC
101-0000-42600
0
$47.86
$47.86-
8/20/15
M NR
RE
k
DEPAZZA, DENNIS & LEANN-
CHECK,
R8-611
1450
PJU
Total Paid f6rELECTRICAL- NEW CONSTRUCTION:: "$192.89 $192.89
AA
g DESCRIPTION21,
m g
-OUNT,
�T
AMOUN�
-.4i, wi
-PAID
Ej
wn_
V.
APPLIANCE REPAIR/ALTERATION.
-101:0000-42402
0
$12.09
$u.09
8/20/15
§
AIR t
"Na"All �RECEII
a C H E C
�t RN� 0,121ik.141�
IN
MIR
W r 5� o '00,
ml? Nt
DEPAZZA, DENNIS & LEANN,
CHECK
R861.1
1 . 450
Pi U
iREStRIRTION5,".
zr
16UNTE
'T
'ACCOUNT
7
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
-0
x$4.83
$4.93
8/20/15
M
ETHOI)zf�, -�M
N;M.� v
03"
.. ...........
',;CLTD�BYI:�,t
�Y'_,AIMB
MUIR
',J
DEPAZZA, DENNIS & LEANN
CHECK
R8611
1450
PJU
Total Paid forMECHANICAL: $16.92 $16.92
MUM
-AC -OUNT 5.
ag X
-A IV IO'UNT`;1
TA
PAID DATE,
-PAI
0 in't-NI"IN.
R
kqj
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$21.75
$21.75
8/20/15
1g%zg%_,�. _"WE
41
g gp-,
gg
EIPV#?�
-r,,;CHECK `#
CL�By:' -
1
�y
4,
L
DEPAZZA, DENNIS &-LEANN
-CHECK
R8611
1450
PJU
% �h �4_
'ACCOUNT WIN A
QTY0-
RA ggr"
AMOUNT
.z,-,DESCRIPT1ON
WM Y' M,
41�7 N.4
il��'P:W:114.110
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0-
$17.40
$17.40
8/20/15
Z-1; M A
tPAID BY V
5ftA g- v _Lffi ....'i'I
an "'
ME
IN
5_ i-
AN 10 m
R
DEPAZZA, DENNIS& LEANN
CHECK,
RN11
1450
PJU
W Tw
Niff
ow"kw'.
iq-%
,gm- p .
T�
AMOUNT N,
- '
llqi�
g!
;MV ,fl
W�,;Wsm
ARRMIX11111
�g
RINI 'R
WNW
REMODEL, FIRST 100 SF.
101-0000-42400
10
$49.31
$49.31
8/20/15
PAID BY� �.#&%mg
`KM 01
qpg t j 6 Rv. RV
�Nm
5
tE I P M#
w5_1K_ ... .. ..... .
LTD BY
_p.
P NO
,ffiMETH(
A-
5 IN
DEPAZZA, DENNIS & LEANN,
CHECK
R86111
4450
Pj.0
m!
DESC RIRTION5'ff,,5jm. `RMWM
M, T,5;'..
M, T, 51 ,
v -nACCOUNTK,'...
QTY
QT
MA XV
��AMOUNT'
R
2tZ, , �� � El�n
7
REMODEL, FIRST 500 SF PC
101-10000-42.600,
0
$134.88
$134.88
8/20/15
�,M --PAID BY',;`M*U` W.."14
gm
M. Ok
0- ��eNRECEIP.T
-4�
"tLTD�13Y,
BONN=
ammam"O
DEPAZZA DENNIS &LEANN
CHECK
R8611
1450-
�Pju
4. $223.34'
Total Paid for REMODEL: $Z.23.3
DESCRIPTION
ACCOUNT Ȣ
w.
QTY
'AMOUNT
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$0.50
$0.50
8/20/15
'PAID BY
p; METHOD °
. RECEIPT #.
CHECK #
CLTD BY
DEPAZZA, DENNIS & LEANN
CHECK
R8611
1450
PJU
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $0.50 $0.50
TOTALS: $434.65 $434.65
Description: ESPLANADE / DE PAZZA / CONVERT 3RD GARAGE PARKING TO LIVING
Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED -CONDITIONS
Applied: 6/10/2015 SKH
Approved: 8/20/2015 JJO
Parcel No: 609580012 Site Address: 43524 CALLE ESPADA LA QUINTA,CA 92253
Subdivision: TR 29323-1 Block: Lot: 90
Issued:
Lot Scl Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $3,500.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
6/10/2015
Details: CONVERT 3RD CAR GARAGE TO LIVING SPACE. A INSPECTION WILL BE REQUIRED WHEN DRYWALL IS REMOVED TO VARIFY NO SHEAR
WALLS ARE BEING REMOVED. IF SHEAR WALLS ARE ALTERED, STRUC CALCS•WILL BE REQUIRED. 2013 CALIFORNIA BUILDING CODES.
71,
Applied to Approved
Printed: Thursday, August 20, 2015 4:51:42 PM 1 of 4 CR
- SYSTE1v1S
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
NOTE
STEPHANIE KHATAMI
6/10/2015
6/10/2015
NEED DRIVER LICENSE FOR OWNER BUILDER FORM
COMPLETION, DIDN'T SCAN TO ATTACHMENTS.
PLAN CHECK PICKED UP
JIM JOHNSON
6/17/2015
6/17/2015
PLANS PICKED UP BY IEANN DEPAZZA
PLAN CHECKSUBMITTAL
STEPHANIE KHATAMI
6/10/2015
6/10/2015
RECEIVED
PLAN CHECK SUBMITTAL
STEPHANIE KHATAMI
8/20/2015
8/20/2015
RECEIVED
TELEPHONE CALL
JIM JOHNSON
6/12/2015
6/12/2015
CALLED OWNER TO PICK UP CORRECTIONS
CONDITIONS
CONDITION DATE DATE
CONTACT DATE ADDED 7_
STATUS REMARKS NOTES
I I
TYPE REQUIRED SATISFIED
Printed: Thursday, August 20, 2015 4:51:42 PM 1 of 4 CR
- SYSTE1v1S
(READY TO ISSUE
CHECKLIST
I
18/20/2015I
CLTD
I
I
PENDING
BY
BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00
8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU
NAME TYPE
NAME
ADDRESSl
CONTACTS
CITY
STATE
ZIP
PHONE FAX EMAIL
APPLICANT
DEPAZZA, DENNIS & LEANN 43254 CALLE ESPADA
LA QUINTA
CA
92253
(
FINANCIAL INFORMATION
CLTD
DESCRIPTION ACCOUNT QTY AMOUNT PAID
PAID DATE RECEIPT # CHECK # METHOD PAID BY
BY
BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00
8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU
LEANN
Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $1.00
BSA:
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$145.03
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
1,0005E
LEANN
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$47.86
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
1,000SF, PC
LEANN
Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89
APPLIANCE
101-0000-42402
0
$12.09
$12.09
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
REPAIR/ALTERATION
LEANN
APPLIANCE
101-0000-42600
0
$4.83
$4.83
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
REPAIR/ALTERATION PC
LEANN
.
Total Paid for MECHANICAL: $16.92 $16.92
REMODEL, EA
101-0000-42400
0
$21.75
$21.75
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
ADDITIONAL 500 SF
LEANN
REMODEL,
101-0000-42600
0
$17.40
$17.40
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
ADDITIONAL 5000 SF PC
LEANN
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
LEANN
Printed: Thursday, August 20, 2015 4:51:42 PM 2 of 4
�1■�/J'
..J L SYSTEiMS
Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177
SYSTEMS
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS.. NOTES
FINAL" BLD
RETURNED
REVIEWS
STATUS
REMARKS
Attachment Type
REVIEW TYPE
REVIEWER
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
NON-STRUCTURAL-
BUILDING
6/10/2015
6/17/2015
6/12/2015
REVISIONS REQUIRED
STEPHANIE KHATAMI
HOA APPROVAL 06-10-
1 WK
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$134.88
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
PC
APPROVED
1 WK
LEANN
Total Paid forREMODEL:- $223.34 $223.34
SMI - RESIDENTIAL
101-0000-20308
0
$0.50
$0.50
8/20/15
R8611
1450
CHECK
DEPAZZA, DENNIS &
PJU
LEANN
Total Paid forSTRONG MOTION INSTRUMENTATION SMt $0.50 $0.50
TOTALS:, .65
Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177
SYSTEMS
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS.. NOTES
FINAL" BLD
RETURNED
REVIEWS
STATUS
Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177
SYSTEMS
ATTACHMENTS
RETURNED
REVIEWS
STATUS
REMARKS
Attachment Type
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
SUBDIR
ETRAKIT ENABLED
DOC
NOTES
JIM JOHNSON
43-524 CALLE
43-524 CALLE
DATE
NON-STRUCTURAL-
BUILDING
6/10/2015
6/17/2015
6/12/2015
REVISIONS REQUIRED
STEPHANIE KHATAMI
HOA APPROVAL 06-10-
1 WK
BUCKET
0
lS.pdf
I 15.pdf
NON-STRUCTURAL -
JIM JOHNSON
8/20/2015
8/20/2015
8/20/2015
APPROVED
1 WK
Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177
SYSTEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
6/12/2015
JIM JOHNSON
43-524 CALLE
43-524 CALLE
0
ESPADA.docx
ESFADA.docx
DOC
6/15/2015
STEPHANIE KHATAMI
HOA APPROVAL 06-10-
HOA APPROVAL 0640-
0
lS.pdf
I 15.pdf
Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177
SYSTEMS
NOW ald(M
sof OF TKtU
Printed: Thursday, August 20, 2015 4:51:42 PM 4 of 4
�LJ U LJ LJ SYSTEMS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
8/20/2015
STEPHANIE KHATAMI
OWNER BUILDER 08-20-
OWNER, BUILDER 08-20-
0
15.pdf
15.pdf
Printed: Thursday, August 20, 2015 4:51:42 PM 4 of 4
�LJ U LJ LJ SYSTEMS
I /
n2 4
a,,2 tte' •.r •ssi5 .Y'...L"3.. ,'j A a"A+,p,.` -d a.4�• �`�' :.5� -� Y' Yt.•
°IR.ermltT.RAKw g-
4.,..,. .�,; .,-> :; z,..rsX ._.. i�: E x .z, .,�.. 4r Fy: wc. r4* • ,. , xi :$=i 6,5,.'
!:^,.'qi..roi'gt�a�..:'�".-��
'?".-x . ax-i"`YY'�'=W'4.^.�'d�: �' 6b1.�^°�i"..��nP"'�f Jui": EkY'fti� �T-� '.� ��s.y �' "''�tC�Y .�:�'i,.�<li:�'. �ri, � .�._ �«��>�C i -'>�s .iT�S� �"�i : S�•s: �:44 �. iJ!Tt �y�r?SV:. �d 4f�'�,=•,5. �. �i'�S`' _ �& 'a4-t� 5}�3�S�.r s�S�h:.L
�� �� �': �!B,RES2015=02x23�� ;fAddress 435�24CrQLLE�ESPA�DA► � :Ann: =609580012 '„ - ���x r,, � 1������'`�"� ,. �����"�.:,$434:65`§'
'�,( F�d''i'e«Fr!3`:�ia_T,n.�[s'a'$s `.��,Cit'��}r`GfiEE� ?.5�e."-i�fRita,�ta:az �fit�,�,•,a �:�;£<�a�1�5z`Ai'�.'�.��n�4v�;3c'."4'sx��`.�'�.a'&'.':�lc':�.��xrr??b�n�„i�4:mz•{"!�._:P�4�;r.�'"�4"iw. ���x?`.:. 3z,,-�`i�nL”i�e�?`4`^,ro�'�'.sA�.-.."'�i-x�.+r 'R�`.3"�a�...iEa"�5?.:7a$�C'
n.; �' - .:.2�" •La : C. >rf..sas�, ^r�3., r 5� -„ r>.x . pix t'E•:?` 4::.;- ;� �<a"".ras,:nA'x:�.,: e; v $, ;:.. ,"i". s ' . rw'" '`'F'*y,fia'`"s'�'
,�'jax� BUILDING STAND'ARD$ ADMINISTRATION BSAC'.5:; �s M.��^ ,:?:.tis .ate xsCi,r.a 1i.x.: 5z�lxssl 00 �c>:
BSAS 561473 FEE 101-0000-20306 0 $1.00
.:.x,T
v'z m •(�`` K 4
s�z_:�.;s.a�.�'z:�.:,..�ELECfRICAI•,�NEWCONSRUCTIONi�,�fas.ma-`�`�Ixi,��Y„��`x.�.�:.:.:in«.��n.:.:...��h,..i�..?s?�r°^�-'.f�:`,� •�Y;I�`",��'E��`:�^.��',.-ti,s19289�,y,
RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0.' $145.03
RESIDENTIAL, FIRST 1,000SF, PC ' 101-0000-42600 -0 $47.86
:;' ,.... ✓'k' '!Z,st i'- :.?i.'x�t"� ?.t L,r ys<.�-�dz»''n v`� 3: xf ;'.' F..r5�a .. s.,.-..�
zFMECHANICAL�ke 3 k tia ? ✓ € fr xs. f a SFT $1692
'��are £*.>'�4:..,,', :ilre'.zx`;'Yr.. 4 '�s �✓.L'.',.e:�n'n. '.�. ,,,:.-�.i: ��+w,i �. :�'�3'� �� z x ,�".'.
'APPLIANCE REPAIR/ALTERATION PC TOl 0000 42600 0 $4.83
APPLIANCE REPAIR/ALTERATION 101-0000-42402 0,.. $12.09
r^S. 7'. em a3 ro -r"- .T - s. ° S3usi<"i�{y,�,::X� kx �" t.{;+.5 y 4*.i-sc..$':t•e z,'f zt..d.;p x'yz� ,�a�""f« axt :c' 'v^ %s `.`z+ _.., K!e':
3,
..,.....�...� .�.,r _ ..,,...:.�..,.��... �_.;ru;;s.>. .:.;F#�'i�tu.. ... f. _.:..�....-.,. �,�..��, 'r>r-:._�•,�Z»fi"�1. .... :2�:, c..�,� xu: ...�.., .x.r S'�..:�'. �. .ch.2. �F. �.�. .[,e .... ..fx..�_
REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40
REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0, $21.75
REMODEL, FIRST 100 SF 101-0000-42400 0. $49.31
REMODEL, FIRST 500 SF PC 101 0000 42600. 0 $134.88
�3 i Sk
r3iR�.<OKu'n«: .cMk.s.qr :i�as. "'>aR,`?xu0-^.�n;5.,. 0r;B"9z
".
SMI _ RESIDENTIAL 101-0000-20308 0 $0.50
1121 11111 !1se
-- -.. .
.—
Date: Paid: Thursday, August 20, 2015
Paid By: DEPAZZA,•DENNIS & LEANN
Cashier: P1U
-Pay Method: CHECK 1450
Printed: Thursday, August 20, 2015 4:14. PM 1 of 1
cvc;ri.nc
Bin #
City of La Quinta
Building 8i' Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012.
Building Permit Application and Tracking Sheet
Permit #
Project Address: 75524
c
Owner's Name:))e/7/?-/ s 91&1/7/? De ieee-
A. P. Number:
Address: -13254.(W11 S
Legal Description:
City, ST, Zip: 1—aO[ JhAJ04 .92253
Contractor: D
Telephone:hone•
`
Address:
Project Description: h/0Yk, 6rU4 ` z?n
City, ST, Zip:
0747z-- �
Telephone:
/2Z
State Lie. # :
City Lic. #;
Arch., Engr., Designer:
Address:
City, ST, Zip:
Telephone:h
one:
....
aneY
Occupancy:
Con s tr uct ion Type: •
State is
Project (circle one • New Add'n Alter Repairair Demo
�.
Name of Contact Person:
Sq. Ft.:#
Stories:
#Units:
Telephone # of Contact Person:
Estimated Value of Projec : 3 00
APPLICANT: DO NOT WRITE BELOW .THIS LINE
tl
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item'
Amount '
Structural Cas.
Reviewed, ready fo corrections
6
Plan Check Deposit
Truss Cates.
Called Contact Person
Plan Check Balance
Title 24 Cale$.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2". Review, ready for corrections/issue
Electrical .
Subeontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
l
Plans resubmitted .
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
SchoolFees .
I
Total Permit Fees
Date
8/20/15
No.
31907
Owner
DEPAZZA
Address
43524 Calle Espada
City
La Quinta Zip
Tract #
Type
Residential Addition
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
Jurisdiction
Permit #
No. of Units
4���Ft�sc�o
Q BERMUDA DUNES r
to RANCHO MIRAGE d
INDIAN WELLS ti
�. PALM DESERT
LAQUIN�Z�PINDIOTy��y
609-580-012
La Quinta
1
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 43524 Calle Espada 172 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 172 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Mr. Depazza Check No.
Bank Name/Recipient of Certificate Telephone
Funding Exempt
BY Dr. Gary Rutherford
Superintendent
N_
Fee collected /exem
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), Is I
or other payment identified above will begin to run from the dat on
which those amounts are paid to the District(s) or to another pub to
Payment Recd ,$0.00
` yOver/U64e�r�
serve to notify you that the 90 -day approval period in which you may protest the fees
ich the building or installation permit for this project is issued, or from the date on
ity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA.QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT -
PROPERTY OWNER'S PACKAGE
(760)777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been s rriintted yo me listing yourself as the builder of the property
improvements specified atA352-4. Calf �t;�� �Q�(,(,(.p" C-,- q12-5
We are providing you with anOwner-Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated.. An agent'of the owner cannot execute this notice
unless you; the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to signer you understand or verify this information.
�. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder„
building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working" on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
2. I understand building permits are not required to be signed by property owners unless they are responsible for the
,eepstruction and are not hiring a licensed Contractor to assume this responsibility.
3. I understand as an "Owner -Builder" I am the responsible party of record on the permit I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
C4.1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
permits and contracts.
c
pmy
I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
ris
understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
s ctures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
)L8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
9. I understand I may obtain more information regarding my obligations as an."employer" from the Internal Revenue
ervice, the United States Small.Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (275 2) or www.cslb.ca.gov for more information about licensed contractors.
L10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party lega 1 d fin is ly re ns ble for pro ose cpns tion c vi at the following address:
�L. hada 7a Q,th �zzs]
&r,k11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govem Owner -Builders as mell as employers.
12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board my be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy againstunlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the permit is issued to verify the property
owner's signature. /, /--%
Signature of property owner
Date: 66Zo9
091 ao
Mote: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file. the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification -
acceptable to the agency is required to be presented when the permit is issued to verb the property owner's signature.
Property Owner's Signature: Date:
Page 1 of 1
Esplanade
c/o Desert Resort Management, Inc.
42635 Melanie Place
Palm Desert, CA 92211
Customer Care: 760-346-1161 Fax: 760-346-9918
Website: wwwA mintemet.com
Date: June 02, 2015
Project Ref: [90302994] 43524 Calle Espada
Leann DePazza
48263 Chesapeake Place
Indio CA 92201
Dear Leann DePazza,
For the listed project item(s):
Garage Space Changes
I am pleased to inform. you that the Esplanade Architectural Committee has approved your
application with the following stipulations:
Approved with the condition that appropriate building permit be obtained from the city of
La Quinta.
The approval is contingent upon compliance with the specifications set forth in the approved
application. If your change or addition requires a county, city or state permit, it is the responsibility of the
homeowner to obtain this before starting construction.
Please retain this letter in your files. If you have any questions regarding this matter, please
contact Customer Care at 760-346-1161 or e-mail us at
Sincerely,
Jennifer Zeivel
Community Association Manager
j zei vel Caidnn i nternet. corn
Esplanade
***ESTE DOCUMENTO ES MUY IMPORTANTE. SI LISTED NO PUEDE LEER INGLES, POR
FAVOR CONSIGA A ALGUIEN PARA QUE LE TRADUZCA ESTE DOCUMENTO***
httD://www.hoaarc.comlAreCommonResourcesIDocumentsIProi ectDocumentsl9418d4c4695... 6/2/2015
DePazza
43524 Calle Espada
La Quinta, Ca 92253
Building Permit Request Drawing
House Hall 11.5'
A1
4
9
-
��
AC Durt
Laundry Room
47"x47" New
Window
0 '�-------------------- - _
Attit•"
As
S/8 TvAeX Drvwall
,�S
fire walls - Garage celling is
c.hactrnckori 20 Min door Self closing 1'/<"
Garage
506 Sq Ft
F
OF LA QUINTA
`�O & SAFETY DEPT.
A\ p �� �
�P Co S UCTIOiV
Notes:
Outlets are AFIC
Lighting is LED
Insulation in celling is
R38
15L
22
cc,
copy
BUILDING ENERGY ANALYSIS REPORT
PPROJECT:
�ZZrA-.
- 4)eiris Residence
43-524 Calle Espada
La Quinta, CA 92253
Project Designer:
Residence Remodel
43-524 Calle Espada
La Quinta, CA 92253
(803) 610-9483
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780
Job Number:
CITE( OF LA QUINTA
BUILDING & SAFETY DEPT.
Date: APPROVED
FOR CONST01 ICTION
5/15/2015 1 . 7
OATS T O 11
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This pro as approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EneravPro 6.5 by EnerovSoft User Number: 6712 ID:
6 rH C 9- 1 cavy
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *D
Project Name: Remodeled Residence Ca culation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1�F-01
Page 1 of
GENERAL INFORMATION
01
Project Name Remodeled Residence
Building Complies with Computer Performance
02
Calculation Description Title 24 Analysis
02
This building DOES NOT require HERS Verification
03
Project Location 43-524 Calle Espada
03
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 3983
15
Number of Zones 2
16
Slab Area (FT2) 3983
17
Number of Stories 1
18
Addition Cond. Floor Area 171
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) 171
21
Glazing Percentage (-/.T)17.00/0
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 05
06
07
08
Energy Use Standard
(kTDV/ft2-yr) Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 8.92
8.72
0.20
2.2%
Space Cooling 214.34
214.54
-0.20
-0.1%
IAQ Ventilation 0.00
0.00
0.00
0.0%
Water Heating 6.20
6.20
0.00
0.0%
Photovoltaic Offset —
0.00
0.00
—
Compliance Energy Total 229.46
229.46
0.00
0.0%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider:
Report Generated at: 2015-05-15 15:11:33
CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
HERS FEATURE SUMMARY
CF19F-01
Page 2 of 9
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
-- None —
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
None —
Domestic Hot Water System Verifications:
• -- None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 268.26 268.26. 0.00 0.0%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Remodeled Residence
3983
1
6
2
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
residence
Conditioned
HVAC1
3812
14
DHW Sys 1
garge Zone
Conditioned
HVAC1
171
14
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710, Report Generated at: 2015-05-15 15:11:33
CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ��n
Project Name: Remodeled Residence Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1�F-01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
N Wall ex
residence
R-13 Wall
0
Back
1820
234
90
Existing
No
E Wall ex
residence
R-13 Wall
90
Right
2010
156
90
Existing
No
S Wall ex
residence
R-13 Wall
180
Front
1820
160.1
90
Existing
No
W Wall ex
residence
R-13 Wall
270
Left
2010
172
90
Existing
No
Roof
residence
Defaul: 1978 to present
3812
Existing
No
E Wall
garge Zone
R-19 Wall (W.19.2x6.16)
90
Right
225
16
90
New
N/A
S Wall
garge Zone
R-19 Wall (W. 1 9.2x6.16)
180
Front
165
20.1
90
New
N/A
Roof 2
garge Zone
R-38 Roof Attic
171
New
N/A
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
Attic residence
Attic Roofresidence
Ventilated
3
0.1
0.85
No
No
En9ti
No
Attic garge Zone
Attic Roofgarge Zone
Ventilated
0
0.1
0.85
No
No
New
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:33
CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ikn
Project Name: Remodeled Residence Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xm1
CF1i F-01
Page 4 of 9
WINDOWS
01
02
03 04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Multiplie
Width(ft) Height (ft) r
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
ex 3x5
N Wall ex (Back -0)
- -- 1
15.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 6x8
N Wall ex (Back -0)
-- -- 1
48.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 3x5 2
N Wall ex (Back -0)
-- -- 1
15.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 4x6
N Wall ex (Back -0)
- -- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 4x6 2
N Wall ex (Back -0)
-- -- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 6x8 2
N Wall ex (Back -0)
-- -- 1
48.0
0.31
0.18 1
Insect Screen (default)
Existing
No
ex 4x5
N Wall ex (Back -0)
-- -- 1
20.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 45 2
N Wall ex (Back -0)
-- -- 1
20.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 45 3
N Wall ex (Back -0)
-- -- 1
20.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4
E Wall ex (Right -90)
- -- 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 6x8 3
E Wall ex (Right -90)
-- -- 1
48.0
1 0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 2
E Wall ex (Right -90)
-- -- 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 3
E Wall ex (Right -90)
-- -- 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 6x8 4
E Wall ex (Right -90)
-- -- 1
48.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 3x6
E Wall ex (Right -90)
-- -- 1
18.0
0.31
0.18
Insect Screen (default)
Existing .
No
ex 3x6 2
E Wall ex (Right -90)
- -- 1
18.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 5x6
S Wall ex (Front -180)
-- -- 1
30.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 5x6
S Wall ex (Front -180)
- -- 1
30.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 4
S Wall ex (Front -180)
- -- 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x6
S Wall ex (Front -180)
- -- 1
12.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x6 2
S Wall ex (Front -180)
-- -- 1
12.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 5
S Wall ex (Front -180)
-- -- 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 3x6 3
W Wall ex (Left -270)
-- -- 1
18.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 46 3
W Wall ex (Left -270)
- -- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 46 4
W Wall ex (Left -270)
- -- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5
W Wall ex (Left -270)
-- -- 1
10.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5 2
W Wall ex (Left -270)
-- -- 1
10.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 46 5
W Wall ex (Left -270)
-- -- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5 3
W Wall ex (Left -270)
-- -- 1
10.0
0.31
0.18 1
Insect Screen (default)
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04012015-710
HERS Provider:
Report Generated at: 2015-05-15 15:11:33
CERTIFI16 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1�F-01
Page 5 of 9
ex 2x5 4
W Wall ex (Left -270) --
-- 1
10.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5 5
W Wall ex (Left -270) --
— 1
10.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 3x8
W Wall ex (Left -270) --
— 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 6
W Wall ex (Left -270) --
— 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
Window
E Wall (Right -90) --
— 1
16.0
1 0.31
1 0.18
1 Insect Screen (default)
New
N/A
DOORS
01
02
03
04
05
01
02
03
04
05
06
Name
Side of Building
Area (ft2)
U -factor
Status
Verified Existing Condition
Door
S Wall ex
40.0
0.50
Existing
No
Door 2
S Wall ex
20.1
0.50
Existing
No
Door 3
S Wall
20.1
0.50
New
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
• Cavity/ Frame: no insul. /2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofresidence
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Defaul: 1978 to present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 11
0.083
Over Floor Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofgarge Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4'
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -19/2x6
• Exterior Finish: Wood
R-19 Wall (W 19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
0.069
Siding/sheathing/decking
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04012015-710
HERS Provider:
Report Generated at: 2015-05-15 15:11:33
CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1OF-01
Page 6 of S
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
residence
3812
288
None
0.8
No
Existing
No
Slab -on -Grade
garge Zone
171
26
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
(%)
Status
Verified Existing
Condition
DHW Sys 1
DHW
Pipe Insulation, All Lines
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.61 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION '
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution-
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider:
Report Generated at: 2015-05-15 15:11:33
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1�F-01
Page 7 of.9
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
Multi -speed
Heating System
Cooling System
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10.4212
Type
Distribution
Fan
Floor Area
Location
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
3983
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
10.4212
Type
No
No
N/A
Location
system
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing .
No
N/A
System 1
specified)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
COOLING VENTILATION
01 02 03 04
Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
WH Fan 1 61 0.52459 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04012015-710 Report Generated at: 2015-05-15 15:11:33
WD
:ulation Date/Time: 15:09, Fri, May 15, 2015
it File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CFI I•F-01
Page 8 of 9
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:33
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE M&D
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1•F-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify. that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Si at
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
5/15/2015
Address:
CEA/HERS Certification Identification (If applicable):
77-085 Michigan Drive
City/StatePalm Desert, CA 92211
Phone: (760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations:
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Denis Residence Remodel
Company:
Date Signed:
Residence Remodel
Address:
License:
43-524 Calle Espada
City/State/Zip:
Phone:
La Quinta, CA 92253
(803) 610-9483
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:33
17,
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Denis Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
5/15/2015
Project Address
43-524 Calle Espada La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,983
Addition
171
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Roof Wood Framed Attic R11 3,812 Existing
Wall Wood Framed R 13 6,938 Existing
Door Opaque Door no insulation 60 Existing
Slab Unheated Slab -on -Grade - no insulation 3,812 Perim = 288' Existing
Demising Wood Framed R 13 959 New
Roof Wood Framed Attic R38 171 New
Wall Wood Framed R 19 354 New
Door Opaque Door - no insulation 20 New
FENESTRATION Total Area: 678 Glazin Percentage: 17.0 NewlAltered Average U -Factor: 0.31
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Rear (N) 234.0 0.310
0.18 none none Bug Screen
Existing
Right (E) 156.0 0.310
0.18 none none Bug Screen
Existing
Front (S) 100.0 0.310
0.18 none none Bug Screen
Existing
Left (1A0 172.0 0.310
0.18 none none Bug Screen
Existing
Right (E) 16.0 0.310
0.18 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 6.5 by EnerqySoft User Number: 6712
Run Code: 2015-05-15T15:11:54 ID:
Pae 12 of 26
CJ
•
r�
U
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Denis Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
5/15/2015
Project Address
43-524 Calle Espada La Quinta
California Energy Climate Zone 1
CA Climate Zone 15
Total Cond. Floor Area
3,983
Addition
1 171
# of Units
1
INSULATION
Construction Type
Area
Cavity fiz) Special Features Status
Slab Unheated Slab -on -Grade - no insulation 171 Perim = 26' New
FENESTRATION Total Area: 678 Glazing Percentage: 17.0 New/Altered Average U -Factor: 0.31
Orientation Area f 2 U -Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro6.5 by EnerqySoft User Number. 6712
RunCode: 2015-05-15715:11:54 /D:
Pae 13 of 26
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
Awk com liance approach used. Exceptions may apply. Review the respective code section or more information.
4
Building Envelope Measures:
§110.6(a)l:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of ' 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 1 10.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):The
thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(6):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§I50.0(c):
Minimum R-13 insulation in 20 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class It vapor retarder shall be placed over the earth floor of
§I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§ 150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ I50.0(e)I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
150.0(e)1 B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)I C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 1 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in§I50.Oh2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)1 A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R- 12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ I50.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
C.
4
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.0(j)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ I50.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class U vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l :
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§I50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§I50.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:S 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 1 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 1 10.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of §150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)1 C: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§I50.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§I50.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of §150.0(k).
§ I50.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §150.0(k) if: it
§ 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of § 130.5; and all other requirements in ' 150.0(k)2.
§ 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
4
F,
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, 130.2, §130.4, 140.7 and §141.0.
§150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or I50.0(k)9D
'130.2,
shall comply with the applicable requirements in § 110.9, § 130.0, §130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
' ' '
nonresidential garages in 110.9 130.0 § 130.1 130.4, § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130. 1, § 140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 1 10.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through §110.10(e).
§ 1 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10 6 through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§I 10.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 1 10.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through §I 10.10(c)
§ 110.10(d):
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
4
4
'HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
enis Residence
5/15/2015
System Name
Floor Area
HVAC
3,983
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 889
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating S stem1�ti
Sensible
Latent CFM
Sensible
Output per System 89,000
72,629
7,671 4,235
82,002
Total Output Btuh 89,000
0
Output Btuh/s ft 22.3
6,159
5,826
Cooling System
01
0
Output per System 35,5001
37,938
15,452 889
41,794
Total Output Btuh 35,500
0
6,159
122,884
23,123
0
Total Output Tons 3.0
5,826
Total Output Btuh/s ft 8.9
Total Output s ftrron 1,346.4
135,448
Air System
CFM per System
1,400
HVAC EQUIPMENT SELECTION
Airflow cfm
1,400
Existing HVAC
33,657
0
89,000
Airflow cfm/s ft
0.35
Airflow cfm/Ton 473.2
Outside Air %
63.5%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK
33,657
0
Aug 3 PM
89,000
Jan 1 AM
Outside Air cfm/s ft 0.22
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 50 OF
50 OF 92 OF
0
Outside Air
889 cfm Supply Fan
Heating Coil
90 OF
1,400 cfm
—_
ROOM
70 OF Return Fan
70 OF
72 OF
[;�E)
o-
1
1,400 cfm
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 90/69°F
90/69°F 55/53°F
O
c
Outside Air
889 cfm
Supply Fan Cooling Coil
57 / 54 OF
1,400 cfm
57.3%
� - `
ROOM
Return Fan
72/61°F 72/61°F
70/60°F
1,400 cfm
Energ Pro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-05-15715:11:54
/D:
Page 18 of 26
•
ROOM LOAD SUMMARY
Project Name Date
Denis Residence 5/15/2015
System Name Floor Area
HVAC 3,983
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
residence altered residence 1 5,039 70,233 7,418 5,039 70,233 7,418 4,102 78,896
garge Zone New Garage Room 1 124 2,395 252 124 2,395 252 132 3,106
I•T
for zonal
PAGE TOTAL
TOTAL'
5,163 72,6291
7,6711
4,2351
82,0021
5,163 72,629
7,671
4,235
82,002
•
1�
ROOM HEATING PEAK LOADS
Project.Name
Denis Residence
Date
5/15/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name altered residence
Floor Area 3,812.0 f 2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.072
Area
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
Default 1978 to present
3,812.0
X
X
0.0790
46
13,853
R-13 Wall
.6,937.9
0.1020
46
32,553
Double non low a Metal .31.18
662.0
X
0.3100
46
9,440
Wood Door
60.1
X
0.5000
46
1,382
Slab -On -Grade
perim = 288.0
X
0.7300
46
9,671
"R-13 Wall
788.0
X
0.1020
4
322
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface to
X 3,812 X
Area Ceiling
another room
14.00 X 0.266
Height ACH
Page Total
/60] X
AT
67,220
= 11,675
I TOTAL HOURLY HEAT LOSS FOR ROOM 78,896
EnergyPro 6.5 by EnergySoR User Number., 6712 Run Code: 2015-05-15715:11:54 ID: Page 20 of 26
C
0
ROOM HEATING PEAK LOADS
Project Name
Denis Residence
Date
5/15/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name New Garage Room
Floor Area 171.0 ft2
Indoor Dry Bulb Temperature 68 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
1.072
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
I X
X
X
AT *F
Btu/hr
R-38 Roof Attic
171.0
0.0260
42
=
187
R-19 Wall (W. 19.2x6.16)
353.9
0.0740
42
c
=
1,100
Double non low a Metal .31.18
16.0
0.3100
42
208
Wood Door
20.1
0.5000
42
_
422
Slab -On -Grade
perim = 26.0
0.7300
42
_
797
'R-13 Wall
171.0
0.1020
-4
c
=
=
-70
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
I=
=
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X
Schedule Air Sensible
Fraction
through an interior surface
X 171 X
Area
another room
14.00 X 0.257
Height ACH
Page Total
/60] X 42
AT
2,644
= 462
TOTAL HOURLY HEAT LOSS FOR ROOM 3,106
EnergyPro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-05-15715:11:54 /D: Page 21 of 26
•
•
1�
RESIDENTIAL ROOM COOLING LOAD SUMMARY
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Project Name
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
Date
Denis Residence
12.9
0.0
12.9
48.0
1
5/15/2015
ROOM INFORMATION
15.0
12.9
DESIGN CONDITIONS
12.9
24.0
12.9
Room Name
altered residence
Outdoor Dry Bulb Temperature
12.9
112 OF
Floor Area
48.0
3,812.0 ft2
Outdoor Wet Bulb Temperature
12.9
78 OF
Indoor Dry Bulb Temperature
0.0
70 OF
Outdoor Daily Range:
12.9
0.0
34 OF
1 20.0
1 12.9
Page Total
Opaque Surfaces
Orientation
Area U -Factor
CLTD'
Btu/hr-
Default 1978 to present
(W)
3,812.0
X
0.0790
X
56.0
=
16,864
R-13 Wall
(N)
1,586.0
X
0.1020
X
23.0
=
3,721
R-13 Wall
(E)
1,854.0
X
0.1020
X
33.0
=
6,241
R-13 Wall
(S)
1,659.9
X
0.1020
X
26.0
=
4,402
Wood Door
(S)
60.1
X
0.5000
X
26.0
=
781
R-13 Wall
(W)
1,838.0
X
0.1020
X
33.0
=
6,187
'R-13 Well
788.0
X
0.1020
X
5.0
=
402
X
X
=
X
X
=
Page Total
1 38,598
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FPnactratinn
ex 3x5
ex 6x8
ex 3x5
ex 4x6
ex 4x6
ex 6x8
ex 4x5
ex 4x5
ex 05
Internal Gain
Oripntatinn
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
12.9
15.0
12.9
0.0
12.9
48.0
12.9
0.0
12.9
15.0
12.9
0.0
12.9
24.0
12.9
0.0
12.9
24.0
12.9
0.0
12.9
48.0
12.9
0.0
12.9
20.0
12.9
0.0
12.9
20.0
12.9
0.0
12.9
1 20.0
1 12.9
Page Total
Btulhr
193
618
193
309
309
618
258
1 2581
1 3,0141
11.4 Occupants X 245 Btuh/occ. = 2,802
3,812 Floor Area X 0.50 w/sgft = 1 6,505
Infiltration: 1.072 X 0.94 X 244.58 X 42 = C
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,2331
Latent Gain Btu/hr
Occupants 11.4 Occupants X 155 Btuh/occ. = 1,773
Infiltration: 4,806 X 0.94 X 244.58 X 0.00514 = 5,646
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,773
17,
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name7511512015
ate
Denis Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name altered residence Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,812. 0 ft' Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF
Opaque Surfaces Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
=
=
=
=
=
=
=
=
=
0.0
12.9
8.0
23.6
0.0
12.9
48.0
23.6
0.0
12.9
8.0
23.6
0.0
12.9
8.0
23.6
0.0
12.9
'48.0
23.6
0.0
12.9
18.0
23.6
0.0
12.9
18.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
ex 2x4
ex 6x8
ex 2x4
ex 2x4
ex 6x8
ex 3x6
ex 3x6
ex 5x6
ex 5x6
Orientation
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
12.9
8.0
23.6
0.0
12.9
48.0
23.6
0.0
12.9
8.0
23.6
0.0
12.9
8.0
23.6
0.0
12.9
'48.0
23.6
0.0
12.9
18.0
23.6
0.0
12.9
18.0
23.6
0.0
12.9
30.0
12.9
0.0
12.9
30.0
12.9
Page Total
Btu/hr
Btulhr
189
1,131
189
189
1,131
424
424
386
386
4,4481
Internal Gain Btu/hr
occupants 11.4 Occupants X 245 Btuh/occ. = 2,802
Equipment 3Floor Area X 0.50 w/sgft
Infiltration: 1.072 X 0.94 X 244.58 X 42 = 10,299
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,2331
Latent Gain Btu/hr
Occupants 11.4 Occupants X 155 Btuh/occ. = 1,773
Infiltration: 4,806 X 0.94 X 244.58 X 0.00514 = 5,646
Air Sensible CFM ELA AW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,773
EneravPro 6.5 by EneravSoft User Number- 6712 RunCode: 2015-05-15715:11:54 /D: Pape 23 of 26 1
C
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Namee
Dat
Denis Residence 5/15/2015
:ielePi7-f►l3esii.�7��Ie ����[diL`L�i Ie .7�
Room Name
altered residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3, 812.0 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Daily Range:
34 OF
Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X'
X
X
X
CLTD'
=
=
=
=
=
_
=
=
=
GLF
=
=
=
=
=
=
=
=
=
0.0
12.9
8.0
12.9
0.0
12.9
12.0
12.9
0.0
12.9
12.0
12.9
0.0
12.9
8.0
12.9
0.01
12.9
18.0
23.6
0.0
12.9
24.0
23.6
0.0
12.9
24.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
ex 2x4
ex 2x6
ex 2x6
ex 2x4
ex 3x6
ex 4x6
ex 4x6
ex 2x5
ex 2x5
Internal Gain
Orientation
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
12.9
8.0
12.9
0.0
12.9
12.0
12.9
0.0
12.9
12.0
12.9
0.0
12.9
8.0
12.9
0.01
12.9
18.0
23.6
0.0
12.9
24.0
23.6
0.0
12.9
24.0
23.6
0.0
12.9
10.0
23.6
0.0
12.9
10.0
1 23.6
Page Total
11.4 Occupants X 245 Btuh/occ.
3,812 Floor Area X 0.50 w/sqft
Infiltration: 1.072 X 0.94 X 244.58 X 42 =
Air Sensible CFM ELA AT
Btu/hr
0
Btu/hr
103
154
154
103
424
566
566
236
236
2, 541
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,2331
Gain
Is 11.4 Occupants X 155 Btuh/occ.
Infiltration: 4,806 X 0.94 X 244.58 X 0.00514 =
Air Sensible CFM ELA AW
• TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1
Btu/hr
=
1,7
5,646
1.773
17,
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Denis Residence
1 5/15/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
altered residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,812. 0 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area
U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area
GLF Area GLF
Btu/hr
ex 4x6
(W)
0.0 X 12.9 +
24.0 X
23.6 =
566
ex 2x5
0.0 X 12.9 +
10.0 X
23.6 =
236
j ex 2x5
(lM
0.0 X 12.9 +
10.0 X
23.6 =
236
ex 2x5
(W)
0.0 X 12.9 +
10.0 X
23.6 =
236
ex 3x8
(tM
0.0 X 12.9 +
24.0 X
23.6 =
566
ex 2x4
(W)
0.0 X 12.9 +
8.0 X
23.6 =
189
X +
X
=
X +
X
=
X +
X
=
Page Total
2.02
Internal Gain
Btu-/hr-
tulhrOccu
Occupants
ants
11.4 Occupants X
245
Btuh/occ.
=
2,802
Equipment
3,812 Floor Area X
0.50
w/sgft
=
6,505
Infiltration: 1.072
X 0.94 X 244.58 X 42 =
10,299
Air Sensible
CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
70,233
Latent Gain
Btulhr
Occupants
11.4 Occupants X 155
Btuh/occ.
=
1,773
Infiltration: 4,806
X 0.94 X 244.58 X 0.00514 =
5,646
Air Sensible
`
CFM ELA
AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,773
Ene Pro 6.5 by EnemySoft
User Number: 6712 Run Code: 2015-05-15715:11:54 ID:
Page 25 of 26
•
�7,
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Denis Residence
5/15/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
New Garage Room
Outdoor Dry Bulb Temperature
112 OF
Floor Area
171.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof Attic
(N) 171.0 X 0.0260
X
56.0 =
249
R-19 Wall (W. 19.2x6.16)
(E) 209.0 X 0.0740
X
33.0 =
510
R-19 Wall (W. 19.2x6.16)
(S) 144.9 X 0.0740
X
26.0 =
279
Wood Door
(S) 20.1 X 0.5000
X
26.0 =
261
`R-13 Wall
171.0 X 0.1020
X
-5.0 =
-87
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1,212
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area _ GLF Area
GLF
Btulhr
Window
(E) 0.0 X 12.9 +
16.0
X 23.6
= 377
X +
X
=
I
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +1
X
=
Page Total
37
Internal Gain
Btu/hr
Occupants
0 5 Occupants X 245
Btuh/occ.
=
126
Equipment
171 Floor Area X 0.50
w/sgft
=
292
Infiltration: 1.072
X 0.89 X 10.97 X 37 =
388
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
2,395
Latent GainBtu/hr
Occupants
0 5 Occupants X 155
Btuh/occ.
=
80
Infiltration: 4,806
X 0.89 X 10.97 X 0.00367 =
173
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
80
EnergyPro 6.5 by EnerqySoft
User Number: 6712 RunCode: 2015-05-15T15:11:54 ID:
Page 26 of 26
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ��n
Project Name: Remodeled Residence Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1tF-01
Page 1 of "9
GENERAL INFORMATION
01
Project Name Remodeled Residence
02 This building DOES NOT req ON, HEt.RS Ve� cat -o MI II k R7 1 ' I I
02
Calculation Description Title 24 Analysis
03 This building incorporates one or more Special Feat�ui�es shownbelow--'-' -- � � � � A"�
03
Project Location 43-524 Calle Espada
i_Jr Ir N
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 3983
15
Number of Zones 2
16
Slab Area (FT2) 3983
17
Number of Stories 1
18
Addition Cond. Floor Area 171
19
Natural Gas Available Yes
20
Addition Slab Area (FT2) 171
21
Glazing Percentage (%) 17.0%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT req ON, HEt.RS Ve� cat -o MI II k R7 1 ' I I
)111 11
03 This building incorporates one or more Special Feat�ui�es shownbelow--'-' -- � � � � A"�
y f – rt If tc t—* `V` S
i_Jr Ir N
ENERGY USE SUMMARY
04 05
06
07
08
Energy Use Standard
(kTDV/ft2-yr) Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 8.92
8.72
0.20
2.2%
Space Cooling 214.34
214.54
-0.20
-0.1%
IAQ Ventilation 0.00
0.00
0.00
0.0%
Water Heating 6.20
6.20
0.00
0.0%
Photovoltaic Offset ----
0.00
0.00
---
Compliance Energy Total 229.46
229.46
0.00
0.0%
Registration Number: 215-A0130771A-Ol066 0000 45 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standard c2e18 449"Al Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
CERTIFIOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE D CF1�F-01
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
-- None --
Cooling System Verifications:
-- None --
HVAC Distribution System Verifications:
• -- None —
Domestic Hot Water System Verifications:
• -- None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and comporients not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
.....+-. H4 F.o-+•.. ....+.... amu•.,..,. arr -- ...v.. �,
Refer nce Energy Uses` Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)'268:26 1 w. 268.26 0.00 0.0%
includes calculated Appliances and Miscellaneous Energy Ose (AMEU)MIERS PROVIDER
N.
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Remodeled Residence
3983
1
6
2
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
residence
Conditioned
HVAC1
3812
14
DHW Sys 1
garge Zone
Conditioned
HVAC1
171
14
DHW Sys 1
Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF10F-01
Page 3 of'b
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (W)
Tilt
(deg)
Status
Verified
Existing
Condition
N Wall ex
residence
R-13 Wall
0
Back
1820
234
90
Existing
No
E Wall ex
residence
R-13 Wall
90
Right
2010
156
90
Existing
No
S Wall ex
residence
R-13 Wall
180
Front
1820
160.1
90
Existing
No
W Wall ex
residence
R-13 Wall
270
Left
2010
172
90
Existing
No
Roof
residence
Defaul: 1978 to present
0 Y
a 0.1V �
3812
No
No
Existing
No
E Wall
garge Zone _
R-19 Wall (W. 19.2x6.16)
90
Right
225
16
90
New
N/A
S Wall
garge Zone
R-19 Wall (W.19.2x6.16)
180
Front
165
20.1
90
New
N/A
Roof 2
garge Zone
R-38 Roof Attic
171
New
N/A
ATTIC
01
02
03
04
05
06
07
08'
09
10
lag"
#
n �a
Radiant
Statu
Verified Existing
Name
Constructionfir
Type
Roof Rhse
Roof Refle�ct�ance
Roof�Emittance'
Barrier
Cool Roof
s
Condition
Ventilated
3
0:1
D 0.85 �6
� No
No
Existi
No
Attic residence
Attic Roofres�idennce
ng
B
R W— *-*, e
' Xi
: .r""�. A .f A
st3 lot- R
Attic garge Zone
Attic Roofgarge Zone
Ventila ed -
0 Y
a 0.1V �
0 5
No
No
New
No
Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOOD
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1OF-01
Page 4 of tJ
WINDOWS
01
02
03
04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Multiplie
Height (ft) r
Area (ft2)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
ex 3x5
N Wall ex (Back -0)
-
-- 1
15.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 6x8
N Wall ex (Back -0)
--
- 1
48.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 3x5 2
N Wall ex (Back -0)
--
- 1
15.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 46
N Wall ex (Back -0)
- -
--- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 4x6 2
N Wall ex (Back -0)
-
-- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 6x8 2
N Wall ex (Back -0)
-
- 1
48.0
0.31 1
0.18
Insect Screen (default)
Existing
No
ex 4x5
N Wall ex (Back -0)
- -
- - 1
20.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 4x5 2
N Wall ex (Back -0)
---
-- 1
20.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 4x5 3
N Wall ex (Back -0)
----
---- 1
20.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4
E Wall ex (Right -90)
--
- - 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 6x8 3
E Wall ex (Right -90)
----
---- 1
48.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 2
E Wall ex (Right -90) � : ��!
f �� 1 f-
(C8.0
0.3.1
0.18
Insect Screen (default)
Existing
No
ex 2x4 3
E Wall ex (Flight -90)
j
10
X0.18
Insect Screen (default)
Existing
No
ex 6x8 4
_:
E Wall ex' (Ri66k 90)
r _, . ti
_ -_ _ _ _ 1
48.01
~'18,0
`0.31 _
. ,
' 0:18
Insect Screen (default)
Existing
No
ex 3x6
E Wall ex (Right -90) :7
iC---R-
3 ----i` 1 4 . '
II
L0,3 1 iC
0.`18
Insect Screen (default)
Existing
No
ex 3x6 2
E Wall ex (Right -90)
----
---- 1
18.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 5x6
S Wall ex (Front -180)
-- -
- - 1
30.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 5x6
S Wall ex (Front -180)
-
- 1
30.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 4
S Wall ex (Front -180)
--
-- 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x6
S Wall ex (Front -180)
----
-- 1
12.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x6 2
S Wall ex (Front -180)
- 1
12.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 5
S Wall ex (Front -180)
-
- 1
8.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 3x6 3
W Wall ex (Left -270)
-
- 1
18.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 46 3
W Wall ex (Left -270)
-
-- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 46 4
W Wall ex (Left -270)
--
- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5
W Wall ex (Left -270)
---
- 1
10.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5 2
W Wall ex (Left -270)
-
--- 1
10.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 4x6 5
W Wall ex (Left -270)
--
-- 1
24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5 3
W Wall ex (Left -270)
--
- 1
10.0
0.31
0.18
Insect Screen (default)
Existing I
No
Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE M�D
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1�F-01
Page 5 of J
ex 2x5 4
W Wall ex (Left -270) ---
-- 1 10.0
1 0.31
0.18
Insect Screen (default)
Existing
No
ex 2x5 5
W Wall ex (Left -270) ---
— 1 10.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 3x8
W Wall ex (Left -270) --
— 1 24.0
0.31
0.18
Insect Screen (default)
Existing
No
ex 2x4 6
W Wall ex (Left -270) --
— 1 8.0
0.31
0.18
Insect Screen (default)
Existing
No
Window
E Wall (Right -90) ---
1 16.0
0.31
1 0.18
1 Insect Screen (default)
New
N/A
DOORS
01
02
03
04
05
01
02
03
04
05
06
Name
Side of Building
Area (ft)
U -factor
Status
Verified Existing Condition
Door
S Wall ex
40.0
0.50
Existing
No
Door 2
S Wall ex
20.1
0.50
Existing
No
Door 3
S Wall
20.1
0.50
New
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Construction Name
Surface Type
ConstructioTy pe- ,
Framing
Total Cavity
� R -value
Winter Design
U -value
Assembly Layers
Xj�
!` i@
Cavity/Frame: no insul. 12x4 To Chid
�1
2x4 To _Chord of:Roof Truss: 24;
Roof Deck: Wood Sidin /sheathin /deckin g
Attic Roofresidence
Attic Roofs
Wood Framed Ceiling-
C in. O -JC. �
none -,I
x0 644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/ Frame: R-9.1 /2x4
Defaul: 1978 to present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 11
0.083
Over Floor Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-13 / 2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
• Cavity / Frame: no insul. 12x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofgarge Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R -19/2x6
• Exterior Finish: Wood
R-19 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
0.069
Siding/sheathing/decking
Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ��n
Project Name: Remodeled Residence DatelTime: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xmi
CF1�F-01
Page 6 of 9
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (W)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
residence
3812
288
None
0.8
No
Existing
No
Slab -on -Grade
garge Zone
171
26
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Not Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
,(Pistribution Typ'e� "
� C=jWate ate
Number of
k Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Fioe Insulation; All Lines ""
rr^ \ IDHW Heater 1 it 1I
a 1
Annual
Existing
No
WATER HEATERS H F R S P R 0 V t Q F R
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.61 EF
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
Registration Number: 215-Ao130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
J
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE N&D
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
CF1*F-01
Page 7 of b
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
Multi -speed
Heating System
Cooling System
System Type +0'
EERYSEnow ER
Zonally Controlled
Compressor
HERS Verification
Component 1
SplitAirCond - Split air condition
v� �
dCooling
1K.,i��
Type
Distribution
Fan
Floor Area
No
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC1
Other Heating and
Heating
Yes
Cooling
Yes
Air Distribution
HVAC Fan
3983
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Name
System Type +0'
EERYSEnow ER
Zonally Controlled
Compressor
HERS Verification
Component 1
SplitAirCond - Split air condition
v� �
dCooling
1K.,i��
Type
112
R -value
n5C(_
No
N/A
Status
sys e1. m
-
;�
_ ,.fid _
Existing (not
.
Attic
HVAC - DISTRIBUTION SYSTEMS ,*A 11 t 1
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
4.2
Attic
Attic
None
Existing
No
N/A
System 1
specified)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
COOLING VENTILATION
01 02 03 04
Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans
WH Fan 1 61 0.52459 1
Registration Number: 2i5-Ao130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE D CF1*F-01
Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Page 8 of �J
Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml
Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39
C F 1OF-01
Page 9 ofI9
:he California Code of
Bance documents,
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-1515:25:52
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710
HERS Provider: CaICERTS inc.
Report Generated at: 2015-05-15 15:11:39