Loading...
BRES2015-0223Applicant: DEPAZZA, DENNIS & LEANN 43254 CALLE ESPADA LA QUINTA, CA 92253 DO Q AUG 20 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that -.heyr she did not build or improve for the purpose of sale.). ( 1, as owner of the property, am exclusively contracting with licensed contractors to Wristruct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. P.C. or this reason Date: C) Own CONSTRUCTION LENDING A CY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). - Lender's Lender's Add Contractor: DEPAZZA, DENNIS & LEANN 43254 CALLE ESPADA LA QUINTA, CA 92253 (541)912-7051 LIC. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree Oat if I should become subject to the workers' compensation provisions of Sect n 37 of the La shall forthwith comply with tho e prgvpns. Date: S Applican • / WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each.agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. .I agree to comply with all city and county ordinances an laws relating to building construction, and hereby authorize representatives o his city o enter up above• mention d prop rty for -inspection -purposes. Date: Signature (Applicant or Ag t 4664P VOICE (760) 777-7125 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92 FAX (760) 777-7011253 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/20/2015 Application Number: BRES2015-0223 Owner: Property Address: 43524 CALLE ESPADA DEPAZZA, DENNIS & LEANN_ APN: 609580012 43254 CALLE ESPADA Application Description: ESPLANADE / DE PAZZA / CONVERT 3RD GARAGE PARKING TO LIVING LA QUINTA, CA 92253 Property Zoning: Application Valuation: $3,500.00 Applicant: DEPAZZA, DENNIS & LEANN 43254 CALLE ESPADA LA QUINTA, CA 92253 DO Q AUG 20 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that -.heyr she did not build or improve for the purpose of sale.). ( 1, as owner of the property, am exclusively contracting with licensed contractors to Wristruct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. P.C. or this reason Date: C) Own CONSTRUCTION LENDING A CY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). - Lender's Lender's Add Contractor: DEPAZZA, DENNIS & LEANN 43254 CALLE ESPADA LA QUINTA, CA 92253 (541)912-7051 LIC. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree Oat if I should become subject to the workers' compensation provisions of Sect n 37 of the La shall forthwith comply with tho e prgvpns. Date: S Applican • / WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each.agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. .I agree to comply with all city and county ordinances an laws relating to building construction, and hereby authorize representatives o his city o enter up above• mention d prop rty for -inspection -purposes. Date: Signature (Applicant or Ag t Total Paid for REMODEL: $Z.23.3 gmy DESCRIPTION Q PAIDPAIDMATE: 0 s SSAS SB1473 FEE 01-0000-20306 $too, $1.00 8/20/15 -TO ECI(i-44M BY TMAID,13,Y VLTD g'q - g 19- MAN DEPAZZA, DENNIS & LEANN.: CHECK R8611 1450 'PJU Total Paid for BUILDINGSTANDARDS ADMINISTRATION BSA :$i.do $1'00 00 �g­ g PAID `i�YAID'.i IKKACCOWNT MM74_1AMOUNT n E`�% NMA RESIDENTIAL, FIRST 1,000SF 101-0000-.42403 -0 $145.03 $145.03, 8/26/15 "'111, 011-1 PAID BY:N, 20 0 N 4W RECEIPT 'iymlll 117121 40 =_R_ .001 e DEPAZZA, DENNIS.&,LIEANN CHECK R86,11 1450' PJU b EEOUNT45,i, ` 5 HE hyR rQTV `AMOUNT DI '-­z�`T �PAIDZATE.l I RESIDENTIAL, FIRST.1,000SF, PC 101-0000-42600 0 $47.86 $47.86- 8/20/15 M NR RE k DEPAZZA, DENNIS & LEANN- CHECK, R8-611 1450 PJU Total Paid f6rELECTRICAL- NEW CONSTRUCTION:: "$192.89 $192.89 AA g DESCRIPTION21, m g -OUNT, �T AMOUN� -.4i, wi -PAID Ej wn_ V. APPLIANCE REPAIR/ALTERATION. -101:0000-42402 0 $12.09 $u.09 8/20/15 § AIR t "Na"All �RECEII a C H E C �t RN� 0,121ik.141� IN MIR W r 5� o '00, ml? Nt DEPAZZA, DENNIS & LEANN, CHECK R861.1 1 . 450 Pi U iREStRIRTION5,". zr 16UNTE 'T 'ACCOUNT 7 APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 -0 x$4.83 $4.93 8/20/15 M ETHOI)zf�, -�M N;M.� v 03" .. ........... ',;CLTD�BYI:�,t �Y'_,AIMB MUIR ',J DEPAZZA, DENNIS & LEANN CHECK R8611 1450 PJU Total Paid forMECHANICAL: $16.92 $16.92 MUM -AC -OUNT 5. ag X -A IV IO'UNT`;1 TA PAID DATE, -PAI 0 in't-NI"IN. R kq­j REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $21.75 $21.75 8/20/15 1g%zg%_,�. _"WE 41 g gp-, gg EIPV#?� -r,,;CHECK `# CL�By:' - 1 �y 4, L DEPAZZA, DENNIS &-LEANN -CHECK R8611 1450 PJU % �h �4_ 'ACCOUNT WIN A QTY0- RA ggr" AMOUNT .z,-,DESCRIPT1ON WM Y' M, 41�7 N.4 il��'P:W:114.1­10 REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0- $17.40 $17.40 8/20/15 Z-1; M A tPAID BY V 5ftA g- v _Lffi ....'i'I an "' ME IN 5_ i- AN 10 m R DEPAZZA, DENNIS& LEANN CHECK, RN11 1450 PJU W Tw Niff ow"kw'. iq­-% ,gm- p . T� AMOUNT N, - ' llqi� g! ;MV ,fl W�,;Wsm ARRMIX11111 �g RINI 'R WNW REMODEL, FIRST 100 SF. 101-0000-42400 10 $49.31 $49.31 8/20/15 PAID BY� �.#&%mg `KM 01 qpg t j 6 Rv. RV �Nm 5 tE I P M# w5_1K_ ... .. ..... . LTD BY _p. P NO ,ffiMETH( A- 5 IN DEPAZZA, DENNIS & LEANN, CHECK R86111 4450 Pj.0 m! DESC RIRTION5'ff,,5jm. `RMWM­ M, T,5;'.. M, T, 51 , v -nACCOUNTK,'... QTY QT MA XV ­��AMOUNT' R 2tZ, , �� � El�n 7 REMODEL, FIRST 500 SF PC 101-10000-42.600, 0 $134.88 $134.88 8/20/15 �,M --PAID BY',;`M*U` W.."14 gm M. Ok 0- ��eNRECEIP.T -4� "tLTD�13Y, BONN= ammam"O DEPAZZA DENNIS &LEANN CHECK R8611 1450- �Pju 4. $223.34' Total Paid for REMODEL: $Z.23.3 DESCRIPTION ACCOUNT »¢ w. QTY 'AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $0.50 $0.50 8/20/15 'PAID BY p; METHOD ° . RECEIPT #. CHECK # CLTD BY DEPAZZA, DENNIS & LEANN CHECK R8611 1450 PJU Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $0.50 $0.50 TOTALS: $434.65 $434.65 Description: ESPLANADE / DE PAZZA / CONVERT 3RD GARAGE PARKING TO LIVING Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED -CONDITIONS Applied: 6/10/2015 SKH Approved: 8/20/2015 JJO Parcel No: 609580012 Site Address: 43524 CALLE ESPADA LA QUINTA,CA 92253 Subdivision: TR 29323-1 Block: Lot: 90 Issued: Lot Scl Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $3,500.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 6/10/2015 Details: CONVERT 3RD CAR GARAGE TO LIVING SPACE. A INSPECTION WILL BE REQUIRED WHEN DRYWALL IS REMOVED TO VARIFY NO SHEAR WALLS ARE BEING REMOVED. IF SHEAR WALLS ARE ALTERED, STRUC CALCS•WILL BE REQUIRED. 2013 CALIFORNIA BUILDING CODES. 71, Applied to Approved Printed: Thursday, August 20, 2015 4:51:42 PM 1 of 4 CR - SYSTE1v1S CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE STEPHANIE KHATAMI 6/10/2015 6/10/2015 NEED DRIVER LICENSE FOR OWNER BUILDER FORM COMPLETION, DIDN'T SCAN TO ATTACHMENTS. PLAN CHECK PICKED UP JIM JOHNSON 6/17/2015 6/17/2015 PLANS PICKED UP BY IEANN DEPAZZA PLAN CHECKSUBMITTAL STEPHANIE KHATAMI 6/10/2015 6/10/2015 RECEIVED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 8/20/2015 8/20/2015 RECEIVED TELEPHONE CALL JIM JOHNSON 6/12/2015 6/12/2015 CALLED OWNER TO PICK UP CORRECTIONS CONDITIONS CONDITION DATE DATE CONTACT DATE ADDED 7_ STATUS REMARKS NOTES I I TYPE REQUIRED SATISFIED Printed: Thursday, August 20, 2015 4:51:42 PM 1 of 4 CR - SYSTE1v1S (READY TO ISSUE CHECKLIST I 18/20/2015I CLTD I I PENDING BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU NAME TYPE NAME ADDRESSl CONTACTS CITY STATE ZIP PHONE FAX EMAIL APPLICANT DEPAZZA, DENNIS & LEANN 43254 CALLE ESPADA LA QUINTA CA 92253 ( FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU LEANN Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU 1,0005E LEANN RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU 1,000SF, PC LEANN Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 APPLIANCE 101-0000-42402 0 $12.09 $12.09 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU REPAIR/ALTERATION LEANN APPLIANCE 101-0000-42600 0 $4.83 $4.83 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU REPAIR/ALTERATION PC LEANN . Total Paid for MECHANICAL: $16.92 $16.92 REMODEL, EA 101-0000-42400 0 $21.75 $21.75 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU ADDITIONAL 500 SF LEANN REMODEL, 101-0000-42600 0 $17.40 $17.40 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU ADDITIONAL 5000 SF PC LEANN REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU LEANN Printed: Thursday, August 20, 2015 4:51:42 PM 2 of 4 �1■�/J' ..J L SYSTEiMS Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177 SYSTEMS INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS.. NOTES FINAL" BLD RETURNED REVIEWS STATUS REMARKS Attachment Type REVIEW TYPE REVIEWER CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY NON-STRUCTURAL- BUILDING 6/10/2015 6/17/2015 6/12/2015 REVISIONS REQUIRED STEPHANIE KHATAMI HOA APPROVAL 06-10- 1 WK REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $134.88 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU PC APPROVED 1 WK LEANN Total Paid forREMODEL:- $223.34 $223.34 SMI - RESIDENTIAL 101-0000-20308 0 $0.50 $0.50 8/20/15 R8611 1450 CHECK DEPAZZA, DENNIS & PJU LEANN Total Paid forSTRONG MOTION INSTRUMENTATION SMt $0.50 $0.50 TOTALS:, .65 Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177 SYSTEMS INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS.. NOTES FINAL" BLD RETURNED REVIEWS STATUS Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177 SYSTEMS ATTACHMENTS RETURNED REVIEWS STATUS REMARKS Attachment Type REVIEW TYPE REVIEWER SENT DATE DUE DATE SUBDIR ETRAKIT ENABLED DOC NOTES JIM JOHNSON 43-524 CALLE 43-524 CALLE DATE NON-STRUCTURAL- BUILDING 6/10/2015 6/17/2015 6/12/2015 REVISIONS REQUIRED STEPHANIE KHATAMI HOA APPROVAL 06-10- 1 WK BUCKET 0 lS.pdf I 15.pdf NON-STRUCTURAL - JIM JOHNSON 8/20/2015 8/20/2015 8/20/2015 APPROVED 1 WK Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177 SYSTEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/12/2015 JIM JOHNSON 43-524 CALLE 43-524 CALLE 0 ESPADA.docx ESFADA.docx DOC 6/15/2015 STEPHANIE KHATAMI HOA APPROVAL 06-10- HOA APPROVAL 0640- 0 lS.pdf I 15.pdf Printed: Thursday, August 20, 2015 4:51:42 PM 3 of 4 177 SYSTEMS NOW ald(M sof OF TKtU Printed: Thursday, August 20, 2015 4:51:42 PM 4 of 4 �LJ U LJ LJ SYSTEMS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 8/20/2015 STEPHANIE KHATAMI OWNER BUILDER 08-20- OWNER, BUILDER 08-20- 0 15.pdf 15.pdf Printed: Thursday, August 20, 2015 4:51:42 PM 4 of 4 �LJ U LJ LJ SYSTEMS I / n2 4 a,,2 tte' •.r •ssi5 .Y'...L"3.. ,'j A a"A+,p,.` -d a.4�• �`�' :.5� -� Y' Yt.• °IR.ermltT.RAKw g- 4.,..,. .�,; .,-> :; z,..rsX ._.. i�: E x .z, .,�.. 4r Fy: wc. r4* • ,. , xi :$=i 6,5,.' !:^,.'qi..roi'gt�a�..:'�".-�� '?".-x . ax-i"`YY'�'=W'4.^.�'d�: �' 6b1.�^°�i"..��nP"'�f Jui": EkY'fti� �T-� '.� ��s.y �' "''�tC�Y .�:�'i,.�<li:�'. �ri, � .�._ �«��>�C i -'>�s .iT�S� �"�i : S�•s: �:44 �. iJ!Tt �y�r?SV:. �d 4f�'�,=•,5. �. �i'�S`' _ �& 'a4-t� 5}�3�S�.r s�S�h:.L �� �� �': �!B,RES2015=02x23�� ;fAddress 435�24CrQLLE�ESPA�DA► � :Ann: =609580012 '„ - ���x r,, � 1������'`�"� ,. �����"�.:,$434:65`§' '�,( F�d''i'e«Fr!3`:�ia_T,n.�[s'a'$s `.��,Cit'��}r`GfiEE� ?.5�e."-i�fRita,�ta:az �fit�,�,•,a �:�;£<�a�1�5z`Ai'�.'�.��n�4v�;3c'."4'sx��`.�'�.a'&'.':�lc':�.��xrr??b�n�„i�4:mz•{"!�._:P�4�;r.�'"�4"iw. ���x?`.:. 3z,,-�`i�nL”i�e�?`4`^,ro�'�'.sA�.-.."'�i-x�.+r 'R�`.3"�a�...iEa"�5?.:7a$�C' n.; �' - .:.2�" •La : C. >rf..sas�, ^r�3., r 5� -„ r>.x . pix t'E•:?` 4::.;- ;� �<a"".ras,:nA'x:�.,: e; v $, ;:.. ,"i". s ' . rw'" '`'F'*y,fia'`"s'�' ,�'jax� BUILDING STAND'ARD$ ADMINISTRATION BSAC'.5:; �s M.��^ ,:?:.tis .ate xsCi,r.a 1i.x.: 5z�lxssl 00 �c>: BSAS 561473 FEE 101-0000-20306 0 $1.00 .:.x,T v'z m •(�`` K 4 s�z_:�.;s.a�.�'z:�.:,..�ELECfRICAI•,�NEWCONSRUCTIONi�,�fas.ma-`�`�Ixi,��Y„��`x.�.�:.:.:in«.��n.:.:...��h,..i�..?s?�r°^�-'.f�:`,� •�Y;I�`",��'E��`:�^.��',.-ti,s19289�,y, RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0.' $145.03 RESIDENTIAL, FIRST 1,000SF, PC ' 101-0000-42600 -0 $47.86 :;' ,.... ✓'k' '!Z,st i'- :.?i.'x�t"� ?.t L,r ys<.�-�dz»''n v`� 3: xf ;'.' F..r5�a .. s.,.-..� zFMECHANICAL�ke 3 k tia ? ✓ € fr xs. f a SFT $1692 '��are £*.>'�4:..,,', :ilre'.zx`;'Yr.. 4 '�s �✓.L'.',.e:�n'n. '.�. ,,,:.-�.i: ��+w,i �. :�'�3'� �� z x ,�".'. 'APPLIANCE REPAIR/ALTERATION PC TOl 0000 42600 0 $4.83 APPLIANCE REPAIR/ALTERATION 101-0000-42402 0,.. $12.09 r^S. 7'. em a3 ro -r"- .T - s. ° S3usi<"i�{y,�,::X� kx �" t.{;+.5 y 4*.i-sc..$':t•e z,'f zt..d.;p x'yz� ,�a�""f« axt :c' 'v^ %s `.`z+ _.., K!e': 3, ..,.....�...� .�.,r _ ..,,...:.�..,.��... �_.;ru;;s.>. .:.;F#�'i�tu.. ... f. _.:..�....-.,. �,�..��, 'r>r-:._�•,�Z»fi"�1. .... :2�:, c..�,� xu: ...�.., .x.r S'�..:�'. �. .ch.2. �F. �.�. .[,e .... ..fx..�_ REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0, $21.75 REMODEL, FIRST 100 SF 101-0000-42400 0. $49.31 REMODEL, FIRST 500 SF PC 101 0000 42600. 0 $134.88 �3 i Sk r3iR�.<OKu'n«: .cMk.s.qr :i�as. "'>aR,`?xu0-^.�n;5.,. 0r;B"9z ". SMI _ RESIDENTIAL 101-0000-20308 0 $0.50 1121 11111 !1se -- -.. . .— Date: Paid: Thursday, August 20, 2015 Paid By: DEPAZZA,•DENNIS & LEANN Cashier: P1U -Pay Method: CHECK 1450 Printed: Thursday, August 20, 2015 4:14. PM 1 of 1 cvc;ri.nc Bin # City of La Quinta Building 8i' Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012. Building Permit Application and Tracking Sheet Permit # Project Address: 75524 c Owner's Name:))e/7/?-/ s 91&1/7/? De ieee- A. P. Number: Address: -13254.(W11 S Legal Description: City, ST, Zip: 1—aO[ JhAJ04 .92253 Contractor: D Telephone:hone• ` Address: Project Description: h/0Yk, 6rU4 ` z?n City, ST, Zip: 0747z-- � Telephone: /2Z State Lie. # : City Lic. #; Arch., Engr., Designer: Address: City, ST, Zip: Telephone:h one: .... aneY Occupancy: Con s tr uct ion Type: • State is Project (circle one • New Add'n Alter Repairair Demo �. Name of Contact Person: Sq. Ft.:# Stories: #Units: Telephone # of Contact Person: Estimated Value of Projec : 3 00 APPLICANT: DO NOT WRITE BELOW .THIS LINE tl Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item' Amount ' Structural Cas. Reviewed, ready fo corrections 6 Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Title 24 Cale$. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2". Review, ready for corrections/issue Electrical . Subeontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval l Plans resubmitted . Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue SchoolFees . I Total Permit Fees Date 8/20/15 No. 31907 Owner DEPAZZA Address 43524 Calle Espada City La Quinta Zip Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units 4���Ft�sc�o Q BERMUDA DUNES r to RANCHO MIRAGE d INDIAN WELLS ti �. PALM DESERT LAQUIN�Z�PINDIOTy��y 609-580-012 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 43524 Calle Espada 172 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 172 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Mr. Depazza Check No. Bank Name/Recipient of Certificate Telephone Funding Exempt BY Dr. Gary Rutherford Superintendent N_ Fee collected /exem Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), Is I or other payment identified above will begin to run from the dat on which those amounts are paid to the District(s) or to another pub to Payment Recd ,$0.00 ` yOver/U64e�r� serve to notify you that the 90 -day approval period in which you may protest the fees ich the building or installation permit for this project is issued, or from the date on ity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA.QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT - PROPERTY OWNER'S PACKAGE (760)777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been s rriintted yo me listing yourself as the builder of the property improvements specified atA352-4. Calf �t;�� �Q�(,(,(.p" C-,- q12-5 We are providing you with anOwner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated.. An agent'of the owner cannot execute this notice unless you; the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signer you understand or verify this information. �. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder„ building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working" on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 2. I understand building permits are not required to be signed by property owners unless they are responsible for the ,eepstruction and are not hiring a licensed Contractor to assume this responsibility. 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. C4.1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. c pmy I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial ris understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential s ctures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. )L8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. 9. I understand I may obtain more information regarding my obligations as an."employer" from the Internal Revenue ervice, the United States Small.Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (275 2) or www.cslb.ca.gov for more information about licensed contractors. L10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party lega 1 d fin is ly re ns ble for pro ose cpns tion c vi at the following address: �L. hada 7a Q,th �zzs] &r,k11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govem Owner -Builders as mell as employers. 12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board my be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy againstunlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. /, /--% Signature of property owner Date: 66Zo9 091 ao Mote: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file. the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification - acceptable to the agency is required to be presented when the permit is issued to verb the property owner's signature. Property Owner's Signature: Date: Page 1 of 1 Esplanade c/o Desert Resort Management, Inc. 42635 Melanie Place Palm Desert, CA 92211 Customer Care: 760-346-1161 Fax: 760-346-9918 Website: wwwA mintemet.com Date: June 02, 2015 Project Ref: [90302994] 43524 Calle Espada Leann DePazza 48263 Chesapeake Place Indio CA 92201 Dear Leann DePazza, For the listed project item(s): Garage Space Changes I am pleased to inform. you that the Esplanade Architectural Committee has approved your application with the following stipulations: Approved with the condition that appropriate building permit be obtained from the city of La Quinta. The approval is contingent upon compliance with the specifications set forth in the approved application. If your change or addition requires a county, city or state permit, it is the responsibility of the homeowner to obtain this before starting construction. Please retain this letter in your files. If you have any questions regarding this matter, please contact Customer Care at 760-346-1161 or e-mail us at Sincerely, Jennifer Zeivel Community Association Manager j zei vel Caidnn i nternet. corn Esplanade ***ESTE DOCUMENTO ES MUY IMPORTANTE. SI LISTED NO PUEDE LEER INGLES, POR FAVOR CONSIGA A ALGUIEN PARA QUE LE TRADUZCA ESTE DOCUMENTO*** httD://www.hoaarc.comlAreCommonResourcesIDocumentsIProi ectDocumentsl9418d4c4695... 6/2/2015 DePazza 43524 Calle Espada La Quinta, Ca 92253 Building Permit Request Drawing House Hall 11.5' A1 4 9 - �� AC Durt Laundry Room 47"x47" New Window 0 '�-------------------- - _ Attit•" As S/8 TvAeX Drvwall ,�S fire walls - Garage celling is c.hactrnckori 20 Min door Self closing 1'/<" Garage 506 Sq Ft F OF LA QUINTA `�O & SAFETY DEPT. A\ p �� � �P Co S UCTIOiV Notes: Outlets are AFIC Lighting is LED Insulation in celling is R38 15L 22 cc, copy BUILDING ENERGY ANALYSIS REPORT PPROJECT: �ZZrA-. - 4)eiris Residence 43-524 Calle Espada La Quinta, CA 92253 Project Designer: Residence Remodel 43-524 Calle Espada La Quinta, CA 92253 (803) 610-9483 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 Job Number: CITE( OF LA QUINTA BUILDING & SAFETY DEPT. Date: APPROVED FOR CONST01 ICTION 5/15/2015 1 . 7 OATS T O 11 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This pro as approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EneravPro 6.5 by EnerovSoft User Number: 6712 ID: 6 rH C 9- 1 cavy CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *D Project Name: Remodeled Residence Ca culation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1�F-01 Page 1 of GENERAL INFORMATION 01 Project Name Remodeled Residence Building Complies with Computer Performance 02 Calculation Description Title 24 Analysis 02 This building DOES NOT require HERS Verification 03 Project Location 43-524 Calle Espada 03 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3c (710) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.5 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 3983 15 Number of Zones 2 16 Slab Area (FT2) 3983 17 Number of Stories 1 18 Addition Cond. Floor Area 171 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 171 21 Glazing Percentage (-/.T)17.00/0 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use Standard (kTDV/ft2-yr) Design Proposed Design Compliance Margin Percent Improvement Space Heating 8.92 8.72 0.20 2.2% Space Cooling 214.34 214.54 -0.20 -0.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 6.20 6.20 0.00 0.0% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 229.46 229.46 0.00 0.0% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 HERS Provider: Report Generated at: 2015-05-15 15:11:33 CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. HERS FEATURE SUMMARY CF19F-01 Page 2 of 9 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: -- None — Cooling System Verifications: — None — HVAC Distribution System Verifications: None — Domestic Hot Water System Verifications: • -- None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 268.26 268.26. 0.00 0.0% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Remodeled Residence 3983 1 6 2 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 3812 14 DHW Sys 1 garge Zone Conditioned HVAC1 171 14 DHW Sys 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710, Report Generated at: 2015-05-15 15:11:33 CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ��n Project Name: Remodeled Residence Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1�F-01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition N Wall ex residence R-13 Wall 0 Back 1820 234 90 Existing No E Wall ex residence R-13 Wall 90 Right 2010 156 90 Existing No S Wall ex residence R-13 Wall 180 Front 1820 160.1 90 Existing No W Wall ex residence R-13 Wall 270 Left 2010 172 90 Existing No Roof residence Defaul: 1978 to present 3812 Existing No E Wall garge Zone R-19 Wall (W.19.2x6.16) 90 Right 225 16 90 New N/A S Wall garge Zone R-19 Wall (W. 1 9.2x6.16) 180 Front 165 20.1 90 New N/A Roof 2 garge Zone R-38 Roof Attic 171 New N/A ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Statu s Verified Existing Condition Attic residence Attic Roofresidence Ventilated 3 0.1 0.85 No No En9ti No Attic garge Zone Attic Roofgarge Zone Ventilated 0 0.1 0.85 No No New No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:33 CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ikn Project Name: Remodeled Residence Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xm1 CF1i F-01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Multiplie Width(ft) Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 3x5 N Wall ex (Back -0) - -- 1 15.0 0.31 0.18 Insect Screen (default) Existing No ex 6x8 N Wall ex (Back -0) -- -- 1 48.0 0.31 0.18 Insect Screen (default) Existing No ex 3x5 2 N Wall ex (Back -0) -- -- 1 15.0 0.31 0.18 Insect Screen (default) Existing No ex 4x6 N Wall ex (Back -0) - -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 4x6 2 N Wall ex (Back -0) -- -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 6x8 2 N Wall ex (Back -0) -- -- 1 48.0 0.31 0.18 1 Insect Screen (default) Existing No ex 4x5 N Wall ex (Back -0) -- -- 1 20.0 0.31 0.18 Insect Screen (default) Existing No ex 45 2 N Wall ex (Back -0) -- -- 1 20.0 0.31 0.18 Insect Screen (default) Existing No ex 45 3 N Wall ex (Back -0) -- -- 1 20.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 E Wall ex (Right -90) - -- 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 6x8 3 E Wall ex (Right -90) -- -- 1 48.0 1 0.31 0.18 Insect Screen (default) Existing No ex 2x4 2 E Wall ex (Right -90) -- -- 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 3 E Wall ex (Right -90) -- -- 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 6x8 4 E Wall ex (Right -90) -- -- 1 48.0 0.31 0.18 Insect Screen (default) Existing No ex 3x6 E Wall ex (Right -90) -- -- 1 18.0 0.31 0.18 Insect Screen (default) Existing . No ex 3x6 2 E Wall ex (Right -90) - -- 1 18.0 0.31 0.18 Insect Screen (default) Existing No ex 5x6 S Wall ex (Front -180) -- -- 1 30.0 0.31 0.18 Insect Screen (default) Existing No ex 5x6 S Wall ex (Front -180) - -- 1 30.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 4 S Wall ex (Front -180) - -- 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 2x6 S Wall ex (Front -180) - -- 1 12.0 0.31 0.18 Insect Screen (default) Existing No ex 2x6 2 S Wall ex (Front -180) -- -- 1 12.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 5 S Wall ex (Front -180) -- -- 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 3x6 3 W Wall ex (Left -270) -- -- 1 18.0 0.31 0.18 Insect Screen (default) Existing No ex 46 3 W Wall ex (Left -270) - -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 46 4 W Wall ex (Left -270) - -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 2x5 W Wall ex (Left -270) -- -- 1 10.0 0.31 0.18 Insect Screen (default) Existing No ex 2x5 2 W Wall ex (Left -270) -- -- 1 10.0 0.31 0.18 Insect Screen (default) Existing No ex 46 5 W Wall ex (Left -270) -- -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 2x5 3 W Wall ex (Left -270) -- -- 1 10.0 0.31 0.18 1 Insect Screen (default) Existing No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04012015-710 HERS Provider: Report Generated at: 2015-05-15 15:11:33 CERTIFI16 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1�F-01 Page 5 of 9 ex 2x5 4 W Wall ex (Left -270) -- -- 1 10.0 0.31 0.18 Insect Screen (default) Existing No ex 2x5 5 W Wall ex (Left -270) -- — 1 10.0 0.31 0.18 Insect Screen (default) Existing No ex 3x8 W Wall ex (Left -270) -- — 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 6 W Wall ex (Left -270) -- — 1 8.0 0.31 0.18 Insect Screen (default) Existing No Window E Wall (Right -90) -- — 1 16.0 1 0.31 1 0.18 1 Insect Screen (default) New N/A DOORS 01 02 03 04 05 01 02 03 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition Door S Wall ex 40.0 0.50 Existing No Door 2 S Wall ex 20.1 0.50 Existing No Door 3 S Wall 20.1 0.50 New No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity/ Frame: no insul. /2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofresidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgarge Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4' R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x6 • Exterior Finish: Wood R-19 Wall (W 19.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04012015-710 HERS Provider: Report Generated at: 2015-05-15 15:11:33 CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1OF-01 Page 6 of S SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab residence 3812 288 None 0.8 No Existing No Slab -on -Grade garge Zone 171 26 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION ' 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution- Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 HERS Provider: Report Generated at: 2015-05-15 15:11:33 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1�F-01 Page 7 of.9 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 Multi -speed Heating System Cooling System System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10.4212 Type Distribution Fan Floor Area Location Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 3983 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10.4212 Type No No N/A Location system Status Condition Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing . No N/A System 1 specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04012015-710 Report Generated at: 2015-05-15 15:11:33 WD :ulation Date/Time: 15:09, Fri, May 15, 2015 it File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CFI I•F-01 Page 8 of 9 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:33 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE M&D Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1•F-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify. that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Si at Jon Scott Company: Signature Date: Scott Design and Title 24, Inc, 5/15/2015 Address: CEA/HERS Certification Identification (If applicable): 77-085 Michigan Drive City/StatePalm Desert, CA 92211 Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations: 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Denis Residence Remodel Company: Date Signed: Residence Remodel Address: License: 43-524 Calle Espada City/State/Zip: Phone: La Quinta, CA 92253 (803) 610-9483 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:33 17, RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Denis Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/15/2015 Project Address 43-524 Calle Espada La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,983 Addition 171 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R11 3,812 Existing Wall Wood Framed R 13 6,938 Existing Door Opaque Door no insulation 60 Existing Slab Unheated Slab -on -Grade - no insulation 3,812 Perim = 288' Existing Demising Wood Framed R 13 959 New Roof Wood Framed Attic R38 171 New Wall Wood Framed R 19 354 New Door Opaque Door - no insulation 20 New FENESTRATION Total Area: 678 Glazin Percentage: 17.0 NewlAltered Average U -Factor: 0.31 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Rear (N) 234.0 0.310 0.18 none none Bug Screen Existing Right (E) 156.0 0.310 0.18 none none Bug Screen Existing Front (S) 100.0 0.310 0.18 none none Bug Screen Existing Left (1A0 172.0 0.310 0.18 none none Bug Screen Existing Right (E) 16.0 0.310 0.18 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 6.5 by EnerqySoft User Number: 6712 Run Code: 2015-05-15T15:11:54 ID: Pae 12 of 26 CJ • r� U RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Denis Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/15/2015 Project Address 43-524 Calle Espada La Quinta California Energy Climate Zone 1 CA Climate Zone 15 Total Cond. Floor Area 3,983 Addition 1 171 # of Units 1 INSULATION Construction Type Area Cavity fiz) Special Features Status Slab Unheated Slab -on -Grade - no insulation 171 Perim = 26' New FENESTRATION Total Area: 678 Glazing Percentage: 17.0 New/Altered Average U -Factor: 0.31 Orientation Area f 2 U -Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro6.5 by EnerqySoft User Number. 6712 RunCode: 2015-05-15715:11:54 /D: Pae 13 of 26 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the Awk com liance approach used. Exceptions may apply. Review the respective code section or more information. 4 Building Envelope Measures: §110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of ' 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 1 10.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i):The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(6): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §I50.0(c): Minimum R-13 insulation in 20 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class It vapor retarder shall be placed over the earth floor of §I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § I50.0(e)I A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. 150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § 150.0(e)I C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 1 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §I50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in§I50.Oh2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). § 150.00)1 A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R- 12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § I50.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. C. 4 2013 Low -Rise Residential Mandatory Measures Summary §150.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.0(j)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § I50.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class U vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)l : space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §I50.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §I50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §I50.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:S 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 1 10.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. §110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 1 10.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of §150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)1 C: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §I50.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. §I50.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § I50.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § I50.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in ' 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and §I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 4 F, 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, 130.2, §130.4, 140.7 and §141.0. §150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or I50.0(k)9D '130.2, shall comply with the applicable requirements in § 110.9, § 130.0, §130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to §130.0(c). §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for ' ' ' nonresidential garages in 110.9 130.0 § 130.1 130.4, § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I 50.0(k) I 2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130. 1, § 140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 1 10.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through §110.10(e). § 1 10.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10 6 through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §I 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 1 10.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through §I 10.10(c) § 110.10(d): shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. 4 4 'HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date enis Residence 5/15/2015 System Name Floor Area HVAC 3,983 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation 889 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating S stem1�ti Sensible Latent CFM Sensible Output per System 89,000 72,629 7,671 4,235 82,002 Total Output Btuh 89,000 0 Output Btuh/s ft 22.3 6,159 5,826 Cooling System 01 0 Output per System 35,5001 37,938 15,452 889 41,794 Total Output Btuh 35,500 0 6,159 122,884 23,123 0 Total Output Tons 3.0 5,826 Total Output Btuh/s ft 8.9 Total Output s ftrron 1,346.4 135,448 Air System CFM per System 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 Existing HVAC 33,657 0 89,000 Airflow cfm/s ft 0.35 Airflow cfm/Ton 473.2 Outside Air % 63.5% Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 33,657 0 Aug 3 PM 89,000 Jan 1 AM Outside Air cfm/s ft 0.22 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 50 OF 50 OF 92 OF 0 Outside Air 889 cfm Supply Fan Heating Coil 90 OF 1,400 cfm —_ ROOM 70 OF Return Fan 70 OF 72 OF [;�E) o- 1 1,400 cfm COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 90/69°F 90/69°F 55/53°F O c Outside Air 889 cfm Supply Fan Cooling Coil 57 / 54 OF 1,400 cfm 57.3% � - ` ROOM Return Fan 72/61°F 72/61°F 70/60°F 1,400 cfm Energ Pro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-05-15715:11:54 /D: Page 18 of 26 • ROOM LOAD SUMMARY Project Name Date Denis Residence 5/15/2015 System Name Floor Area HVAC 3,983 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible residence altered residence 1 5,039 70,233 7,418 5,039 70,233 7,418 4,102 78,896 garge Zone New Garage Room 1 124 2,395 252 124 2,395 252 132 3,106 I•T for zonal PAGE TOTAL TOTAL' 5,163 72,6291 7,6711 4,2351 82,0021 5,163 72,629 7,671 4,235 82,002 • 1� ROOM HEATING PEAK LOADS Project.Name Denis Residence Date 5/15/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name altered residence Floor Area 3,812.0 f 2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.072 Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr Default 1978 to present 3,812.0 X X 0.0790 46 13,853 R-13 Wall .6,937.9 0.1020 46 32,553 Double non low a Metal .31.18 662.0 X 0.3100 46 9,440 Wood Door 60.1 X 0.5000 46 1,382 Slab -On -Grade perim = 288.0 X 0.7300 46 9,671 "R-13 Wall 788.0 X 0.1020 4 322 X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface to X 3,812 X Area Ceiling another room 14.00 X 0.266 Height ACH Page Total /60] X AT 67,220 = 11,675 I TOTAL HOURLY HEAT LOSS FOR ROOM 78,896 EnergyPro 6.5 by EnergySoR User Number., 6712 Run Code: 2015-05-15715:11:54 ID: Page 20 of 26 C 0 ROOM HEATING PEAK LOADS Project Name Denis Residence Date 5/15/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name New Garage Room Floor Area 171.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.072 Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X I X X X AT *F Btu/hr R-38 Roof Attic 171.0 0.0260 42 = 187 R-19 Wall (W. 19.2x6.16) 353.9 0.0740 42 c = 1,100 Double non low a Metal .31.18 16.0 0.3100 42 208 Wood Door 20.1 0.5000 42 _ 422 Slab -On -Grade perim = 26.0 0.7300 42 _ 797 'R-13 Wall 171.0 0.1020 -4 c = = -70 = = = = = = = = = = = = = = = I= = Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface X 171 X Area another room 14.00 X 0.257 Height ACH Page Total /60] X 42 AT 2,644 = 462 TOTAL HOURLY HEAT LOSS FOR ROOM 3,106 EnergyPro 6.5 by EnergySoft User Number: 6712 Run Code: 2015-05-15715:11:54 /D: Page 21 of 26 • • 1� RESIDENTIAL ROOM COOLING LOAD SUMMARY X X X X X X X X X GLF + + + + + + + + + Project Name X X X X X X X X X GLF = = = = = = = = = 0.0 Date Denis Residence 12.9 0.0 12.9 48.0 1 5/15/2015 ROOM INFORMATION 15.0 12.9 DESIGN CONDITIONS 12.9 24.0 12.9 Room Name altered residence Outdoor Dry Bulb Temperature 12.9 112 OF Floor Area 48.0 3,812.0 ft2 Outdoor Wet Bulb Temperature 12.9 78 OF Indoor Dry Bulb Temperature 0.0 70 OF Outdoor Daily Range: 12.9 0.0 34 OF 1 20.0 1 12.9 Page Total Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr- Default 1978 to present (W) 3,812.0 X 0.0790 X 56.0 = 16,864 R-13 Wall (N) 1,586.0 X 0.1020 X 23.0 = 3,721 R-13 Wall (E) 1,854.0 X 0.1020 X 33.0 = 6,241 R-13 Wall (S) 1,659.9 X 0.1020 X 26.0 = 4,402 Wood Door (S) 60.1 X 0.5000 X 26.0 = 781 R-13 Wall (W) 1,838.0 X 0.1020 X 33.0 = 6,187 'R-13 Well 788.0 X 0.1020 X 5.0 = 402 X X = X X = Page Total 1 38,598 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnactratinn ex 3x5 ex 6x8 ex 3x5 ex 4x6 ex 4x6 ex 6x8 ex 4x5 ex 4x5 ex 05 Internal Gain Oripntatinn (N) (N) (N) (N) (N) (N) (N) (N) (N) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 12.9 15.0 12.9 0.0 12.9 48.0 12.9 0.0 12.9 15.0 12.9 0.0 12.9 24.0 12.9 0.0 12.9 24.0 12.9 0.0 12.9 48.0 12.9 0.0 12.9 20.0 12.9 0.0 12.9 20.0 12.9 0.0 12.9 1 20.0 1 12.9 Page Total Btulhr 193 618 193 309 309 618 258 1 2581 1 3,0141 11.4 Occupants X 245 Btuh/occ. = 2,802 3,812 Floor Area X 0.50 w/sgft = 1 6,505 Infiltration: 1.072 X 0.94 X 244.58 X 42 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,2331 Latent Gain Btu/hr Occupants 11.4 Occupants X 155 Btuh/occ. = 1,773 Infiltration: 4,806 X 0.94 X 244.58 X 0.00514 = 5,646 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,773 17, RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name7511512015 ate Denis Residence ROOM INFORMATION DESIGN CONDITIONS Room Name altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,812. 0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = = 0.0 12.9 8.0 23.6 0.0 12.9 48.0 23.6 0.0 12.9 8.0 23.6 0.0 12.9 8.0 23.6 0.0 12.9 '48.0 23.6 0.0 12.9 18.0 23.6 0.0 12.9 18.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration ex 2x4 ex 6x8 ex 2x4 ex 2x4 ex 6x8 ex 3x6 ex 3x6 ex 5x6 ex 5x6 Orientation (E) (E) (E) (E) (E) (E) (E) (S) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 12.9 8.0 23.6 0.0 12.9 48.0 23.6 0.0 12.9 8.0 23.6 0.0 12.9 8.0 23.6 0.0 12.9 '48.0 23.6 0.0 12.9 18.0 23.6 0.0 12.9 18.0 23.6 0.0 12.9 30.0 12.9 0.0 12.9 30.0 12.9 Page Total Btu/hr Btulhr 189 1,131 189 189 1,131 424 424 386 386 4,4481 Internal Gain Btu/hr occupants 11.4 Occupants X 245 Btuh/occ. = 2,802 Equipment 3Floor Area X 0.50 w/sgft Infiltration: 1.072 X 0.94 X 244.58 X 42 = 10,299 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,2331 Latent Gain Btu/hr Occupants 11.4 Occupants X 155 Btuh/occ. = 1,773 Infiltration: 4,806 X 0.94 X 244.58 X 0.00514 = 5,646 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,773 EneravPro 6.5 by EneravSoft User Number- 6712 RunCode: 2015-05-15715:11:54 /D: Pape 23 of 26 1 C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Namee Dat Denis Residence 5/15/2015 :ielePi7-f►l3esii.�7��Ie ����[diL`L�i Ie .7� Room Name altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3, 812.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X' X X X CLTD' = = = = = _ = = = GLF = = = = = = = = = 0.0 12.9 8.0 12.9 0.0 12.9 12.0 12.9 0.0 12.9 12.0 12.9 0.0 12.9 8.0 12.9 0.01 12.9 18.0 23.6 0.0 12.9 24.0 23.6 0.0 12.9 24.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration ex 2x4 ex 2x6 ex 2x6 ex 2x4 ex 3x6 ex 4x6 ex 4x6 ex 2x5 ex 2x5 Internal Gain Orientation Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 12.9 8.0 12.9 0.0 12.9 12.0 12.9 0.0 12.9 12.0 12.9 0.0 12.9 8.0 12.9 0.01 12.9 18.0 23.6 0.0 12.9 24.0 23.6 0.0 12.9 24.0 23.6 0.0 12.9 10.0 23.6 0.0 12.9 10.0 1 23.6 Page Total 11.4 Occupants X 245 Btuh/occ. 3,812 Floor Area X 0.50 w/sqft Infiltration: 1.072 X 0.94 X 244.58 X 42 = Air Sensible CFM ELA AT Btu/hr 0 Btu/hr 103 154 154 103 424 566 566 236 236 2, 541 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,2331 Gain Is 11.4 Occupants X 155 Btuh/occ. Infiltration: 4,806 X 0.94 X 244.58 X 0.00514 = Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 Btu/hr = 1,7 5,646 1.773 17, RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Denis Residence 1 5/15/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name altered residence Outdoor Dry Bulb Temperature 112 OF Floor Area 3,812. 0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr ex 4x6 (W) 0.0 X 12.9 + 24.0 X 23.6 = 566 ex 2x5 0.0 X 12.9 + 10.0 X 23.6 = 236 j ex 2x5 (lM 0.0 X 12.9 + 10.0 X 23.6 = 236 ex 2x5 (W) 0.0 X 12.9 + 10.0 X 23.6 = 236 ex 3x8 (tM 0.0 X 12.9 + 24.0 X 23.6 = 566 ex 2x4 (W) 0.0 X 12.9 + 8.0 X 23.6 = 189 X + X = X + X = X + X = Page Total 2.02 Internal Gain Btu-/hr- tulhrOccu Occupants ants 11.4 Occupants X 245 Btuh/occ. = 2,802 Equipment 3,812 Floor Area X 0.50 w/sgft = 6,505 Infiltration: 1.072 X 0.94 X 244.58 X 42 = 10,299 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 70,233 Latent Gain Btulhr Occupants 11.4 Occupants X 155 Btuh/occ. = 1,773 Infiltration: 4,806 X 0.94 X 244.58 X 0.00514 = 5,646 Air Sensible ` CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,773 Ene Pro 6.5 by EnemySoft User Number: 6712 Run Code: 2015-05-15715:11:54 ID: Page 25 of 26 • �7, RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Denis Residence 5/15/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name New Garage Room Outdoor Dry Bulb Temperature 112 OF Floor Area 171.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (N) 171.0 X 0.0260 X 56.0 = 249 R-19 Wall (W. 19.2x6.16) (E) 209.0 X 0.0740 X 33.0 = 510 R-19 Wall (W. 19.2x6.16) (S) 144.9 X 0.0740 X 26.0 = 279 Wood Door (S) 20.1 X 0.5000 X 26.0 = 261 `R-13 Wall 171.0 X 0.1020 X -5.0 = -87 X X = X X = X X = X X = Page Total 1,212 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area _ GLF Area GLF Btulhr Window (E) 0.0 X 12.9 + 16.0 X 23.6 = 377 X + X = I X + X = X + X = X + X = X + X = X + X = X + X = X +1 X = Page Total 37 Internal Gain Btu/hr Occupants 0 5 Occupants X 245 Btuh/occ. = 126 Equipment 171 Floor Area X 0.50 w/sgft = 292 Infiltration: 1.072 X 0.89 X 10.97 X 37 = 388 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 2,395 Latent GainBtu/hr Occupants 0 5 Occupants X 155 Btuh/occ. = 80 Infiltration: 4,806 X 0.89 X 10.97 X 0.00367 = 173 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 80 EnergyPro 6.5 by EnerqySoft User Number: 6712 RunCode: 2015-05-15T15:11:54 ID: Page 26 of 26 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ��n Project Name: Remodeled Residence Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1tF-01 Page 1 of "9 GENERAL INFORMATION 01 Project Name Remodeled Residence 02 This building DOES NOT req ON, HEt.RS Ve� cat -o MI II k R7 1 ' I I 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more Special Feat�ui�es shownbelow--'-' -- � � � � A"� 03 Project Location 43-524 Calle Espada i_Jr Ir N 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3c (710) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.5 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 3983 15 Number of Zones 2 16 Slab Area (FT2) 3983 17 Number of Stories 1 18 Addition Cond. Floor Area 171 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 171 21 Glazing Percentage (%) 17.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT req ON, HEt.RS Ve� cat -o MI II k R7 1 ' I I )111 11 03 This building incorporates one or more Special Feat�ui�es shownbelow--'-' -- � � � � A"� y f – rt If tc t—* `V` S i_Jr Ir N ENERGY USE SUMMARY 04 05 06 07 08 Energy Use Standard (kTDV/ft2-yr) Design Proposed Design Compliance Margin Percent Improvement Space Heating 8.92 8.72 0.20 2.2% Space Cooling 214.34 214.54 -0.20 -0.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 6.20 6.20 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 --- Compliance Energy Total 229.46 229.46 0.00 0.0% Registration Number: 215-A0130771A-Ol066 0000 45 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standard c2e18 449"Al Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 CERTIFIOF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE D CF1�F-01 Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: -- None -- Cooling System Verifications: -- None -- HVAC Distribution System Verifications: • -- None — Domestic Hot Water System Verifications: • -- None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and comporients not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. .....+-. H4 F.o-+•.. ....+.... amu•.,..,. arr -- ...v.. �, Refer nce Energy Uses` Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)'268:26 1 w. 268.26 0.00 0.0% includes calculated Appliances and Miscellaneous Energy Ose (AMEU)MIERS PROVIDER N. BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Remodeled Residence 3983 1 6 2 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 3812 14 DHW Sys 1 garge Zone Conditioned HVAC1 171 14 DHW Sys 1 Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF10F-01 Page 3 of'b OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (W) Tilt (deg) Status Verified Existing Condition N Wall ex residence R-13 Wall 0 Back 1820 234 90 Existing No E Wall ex residence R-13 Wall 90 Right 2010 156 90 Existing No S Wall ex residence R-13 Wall 180 Front 1820 160.1 90 Existing No W Wall ex residence R-13 Wall 270 Left 2010 172 90 Existing No Roof residence Defaul: 1978 to present 0 Y a 0.1V � 3812 No No Existing No E Wall garge Zone _ R-19 Wall (W. 19.2x6.16) 90 Right 225 16 90 New N/A S Wall garge Zone R-19 Wall (W.19.2x6.16) 180 Front 165 20.1 90 New N/A Roof 2 garge Zone R-38 Roof Attic 171 New N/A ATTIC 01 02 03 04 05 06 07 08' 09 10 lag" # n �a Radiant Statu Verified Existing Name Constructionfir Type Roof Rhse Roof Refle�ct�ance Roof�Emittance' Barrier Cool Roof s Condition Ventilated 3 0:1 D 0.85 �6 � No No Existi No Attic residence Attic Roofres�idennce ng B R W— *-*, e ' Xi : .r""�. A .f A st3 lot- R Attic garge Zone Attic Roofgarge Zone Ventila ed - 0 Y a 0.1V � 0 5 No No New No Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOOD Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1OF-01 Page 4 of tJ WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 3x5 N Wall ex (Back -0) - -- 1 15.0 0.31 0.18 Insect Screen (default) Existing No ex 6x8 N Wall ex (Back -0) -- - 1 48.0 0.31 0.18 Insect Screen (default) Existing No ex 3x5 2 N Wall ex (Back -0) -- - 1 15.0 0.31 0.18 Insect Screen (default) Existing No ex 46 N Wall ex (Back -0) - - --- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 4x6 2 N Wall ex (Back -0) - -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 6x8 2 N Wall ex (Back -0) - - 1 48.0 0.31 1 0.18 Insect Screen (default) Existing No ex 4x5 N Wall ex (Back -0) - - - - 1 20.0 0.31 0.18 Insect Screen (default) Existing No ex 4x5 2 N Wall ex (Back -0) --- -- 1 20.0 0.31 0.18 Insect Screen (default) Existing No ex 4x5 3 N Wall ex (Back -0) ---- ---- 1 20.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 E Wall ex (Right -90) -- - - 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 6x8 3 E Wall ex (Right -90) ---- ---- 1 48.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 2 E Wall ex (Right -90) � : ��! f �� 1 f- (C8.0 0.3.1 0.18 Insect Screen (default) Existing No ex 2x4 3 E Wall ex (Flight -90) j 10 X0.18 Insect Screen (default) Existing No ex 6x8 4 _: E Wall ex' (Ri66k 90) r _, . ti _ -_ _ _ _ 1 48.01 ~'18,0 `0.31 _ . , ' 0:18 Insect Screen (default) Existing No ex 3x6 E Wall ex (Right -90) :7 iC---R- 3 ----i` 1 4 . ' II L0,3 1 iC 0.`18 Insect Screen (default) Existing No ex 3x6 2 E Wall ex (Right -90) ---- ---- 1 18.0 0.31 0.18 Insect Screen (default) Existing No ex 5x6 S Wall ex (Front -180) -- - - - 1 30.0 0.31 0.18 Insect Screen (default) Existing No ex 5x6 S Wall ex (Front -180) - - 1 30.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 4 S Wall ex (Front -180) -- -- 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 2x6 S Wall ex (Front -180) ---- -- 1 12.0 0.31 0.18 Insect Screen (default) Existing No ex 2x6 2 S Wall ex (Front -180) - 1 12.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 5 S Wall ex (Front -180) - - 1 8.0 0.31 0.18 Insect Screen (default) Existing No ex 3x6 3 W Wall ex (Left -270) - - 1 18.0 0.31 0.18 Insect Screen (default) Existing No ex 46 3 W Wall ex (Left -270) - -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 46 4 W Wall ex (Left -270) -- - 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 2x5 W Wall ex (Left -270) --- - 1 10.0 0.31 0.18 Insect Screen (default) Existing No ex 2x5 2 W Wall ex (Left -270) - --- 1 10.0 0.31 0.18 Insect Screen (default) Existing No ex 4x6 5 W Wall ex (Left -270) -- -- 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 2x5 3 W Wall ex (Left -270) -- - 1 10.0 0.31 0.18 Insect Screen (default) Existing I No Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE M�D Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1�F-01 Page 5 of J ex 2x5 4 W Wall ex (Left -270) --- -- 1 10.0 1 0.31 0.18 Insect Screen (default) Existing No ex 2x5 5 W Wall ex (Left -270) --- — 1 10.0 0.31 0.18 Insect Screen (default) Existing No ex 3x8 W Wall ex (Left -270) -- — 1 24.0 0.31 0.18 Insect Screen (default) Existing No ex 2x4 6 W Wall ex (Left -270) -- — 1 8.0 0.31 0.18 Insect Screen (default) Existing No Window E Wall (Right -90) --- 1 16.0 0.31 1 0.18 1 Insect Screen (default) New N/A DOORS 01 02 03 04 05 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition Door S Wall ex 40.0 0.50 Existing No Door 2 S Wall ex 20.1 0.50 Existing No Door 3 S Wall 20.1 0.50 New No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type ConstructioTy pe- , Framing Total Cavity � R -value Winter Design U -value Assembly Layers Xj� !` i@ Cavity/Frame: no insul. 12x4 To Chid �1 2x4 To _Chord of:Roof Truss: 24; Roof Deck: Wood Sidin /sheathin /deckin g Attic Roofresidence Attic Roofs Wood Framed Ceiling- C in. O -JC. � none -,I x0 644 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Cavity / Frame: no insul. 12x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgarge Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x6 • Exterior Finish: Wood R-19 Wall (W.19.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ��n Project Name: Remodeled Residence DatelTime: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xmi CF1�F-01 Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (W) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab residence 3812 288 None 0.8 No Existing No Slab -on -Grade garge Zone 171 26 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type ,(Pistribution Typ'e� " � C=jWate ate Number of k Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Fioe Insulation; All Lines "" rr^ \ IDHW Heater 1 it 1I a 1 Annual Existing No WATER HEATERS H F R S P R 0 V t Q F R 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a Registration Number: 215-Ao130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 J CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE N&D Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml CF1*F-01 Page 7 of b SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 Multi -speed Heating System Cooling System System Type +0' EERYSEnow ER Zonally Controlled Compressor HERS Verification Component 1 SplitAirCond - Split air condition v� � dCooling 1K.,i�� Type Distribution Fan Floor Area No Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 3983 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Name System Type +0' EERYSEnow ER Zonally Controlled Compressor HERS Verification Component 1 SplitAirCond - Split air condition v� � dCooling 1K.,i�� Type 112 R -value n5C(_ No N/A Status sys e1. m - ;� _ ,.fid _ Existing (not . Attic HVAC - DISTRIBUTION SYSTEMS ,*A 11 t 1 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 Registration Number: 2i5-Ao130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE D CF1*F-01 Project Name: Remodeled Residence Calculation Date/Time: 15:09, Fri, May 15, 2015 Page 8 of �J Calculation Description: Title 24 Analysis Input File Name: Res Remodel -Denis -43 524 Calle Espada-15.xml Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-15 15:25:52 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 Report Generated at: 2015-05-15 15:11:39 C F 1OF-01 Page 9 ofI9 :he California Code of Bance documents, Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0130771A-000000000-0000 Registration Date/Time: 2015-05-1515:25:52 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04012015-710 HERS Provider: CaICERTS inc. Report Generated at: 2015-05-15 15:11:39