LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
Da" to
6701 %6 C61 W3 5131199
Signature of Contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section , B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
t:,r;xitll`i'
(This / section need not be completed if the permit valuation is for $100.00 or less).
(Y I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions.
Pate: Applicant
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each personrat
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall,' indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
1 certify that I have read this application and state that the above information is
b� correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the Ave -mentioned property for inspection purposes.
Signature (Owner/Agent) Date
BUILDING PERMIT PERMIT9�#7,�CONTROL#
106 DATE 11►/1•c/97 VALUATION $4,123.00 LOT TRACT 6083
JOB SITE
ADDRESS CSS 48.614 ALLF, FSPr`altt�W-A APN
OWNER CONTRACTOR/DESIGNER/ENGINEER
r:NR1C`0,% BEVERIJ-1i P'!1'1AIX S10UN`'AD1 t11;S'CC-ONS'C1WCi -W
48-614 CALL.' ESPERANZA 16321 AIUMAiN R11S'!' S1'
1A QUIN'1'A ;:"A 92253 k.111ERNI1A' CA 0250A
1rJ04)(11;?-61111 C91.# 4819
USE OF PERMIT
61AUNNO
WXB ANN 12XIS fCKA #1fi51N Al.ithll LATfK,'Ii PARO C01YER
PORC1 vIIA71O
110.49) 51'
ESTIMATED 4.123.wo
PERMITFERSIMMARY
PLAN ry 191?CK FEE 101-Ut;0439-:18 3.16 MI
%`C)N:"TRfJr1'!0NV14 1014911).4184)(} t,^,. no
3=01140 X1OTIC11% 1'irli - 0:USR) 1014100-2.11.000 3 911
�
3-I{ YTAt, ("(NS"1'FiitC"17t 3itf ,,�N!} f'1.AN ( so
0hf0
l
-'j. 'C")TAT. PERMIT FIEMS WTE NOW13
DATE BY DATE FINALED INSPECTOR
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS '
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall- Int. Lath
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
Steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
�i-7-yam
EXHIBIT "1"
ARCHITECTURAL IMPROVEMENT APPLICATION AND AGREEMENT
DATE
NAMES) co ,04,9—(,, &,b7 00,E TA
(Print)
STREET ADDRESS L{� - G, !� ( /� .( (�,�,� ,¢ r✓Z.
LOCAL PHONE - OTHER PHONE
REQUESTED IMPROVEMENT T > Cly �J�c�2 ��'AX 4 j 7-4CAIRo
L,4 l T! CA fl 11 _`P -IX c o(--,, n ; .St` c n d, i n
Approval is requested for the above improvement according to
the plans attached. We have attached two (2) sets. of plans
outlining the work to be done along with a complete description
of the materials and colors to be used. If we are using a
contractor(s), we enclose copies of the Contractor's License.
Attachments:
(1) Two copies of the Architectural Improvement Application.
(2) Two sets of plans with materials and colors to be used.
Note: One set is for the management office; the other
set to be returned to you as "Approved".
(3) Contractor's name and copy of contractor's license. (Not
required if the improvement is under $300.00 or if
"Owner -Builder"). .
(4) Brochures (2) and/or color samples of manufactured products
to be used.
We have read the Architectural Committee Rules and Guidelines
and have furnished copies to all contractors to be engaged by
us and we agree to comply with those Rules and Guidelines.
We also understand that it is our responsibility to insure that
our Contractor(s) comply with said Rules. We acknowledge that
Building Permits for home improvements may be required by the
City of La Quinta. The cost of permits, responsibility for
obtaining them, and the subsequent inspection.s will be our
responsibility. In all cases we recognize the requirement to
be in compliance with applicable building codes including, but
not limited to, those adopted subsequent to the original
completion and acceptance of our dwelling.
Rev. 4-96
10
Page Two
The Association has no responsibility whatever in achieving
compliance with newer building codes which apply as a result
of Homeowner prompted modifications. Further, we understand
that approval will not be granted for any modification which
directly or indirectly conflicts with the Declarations of
Covenants, Conditions and Restrictions. We also understand
we are responsible for the acc-urate determination of property
lines and setbacks (as applicable).
We also understand that we will be responsible for all costs
of .this improvement and for costs associated with any repair
to common area occurring as a result of implementing this
improvement. Examples include, but are not limited to, sprinkler
and irrigation systems, buildings, roofs, exterior walls, lawns,
plants and drainage. Further we recognize that any modifications
to the common area irrigation and landscaping scheme, are subject
to formal acceptance by the Association. Any required remedy
to achieve the required maintenance standard or, irrigation
standard are our responsibility. Additionally, we understand
that the job site must be left reasonably clean at the end of
each day, that no debris nor dirt may be dumped in common area
or left at job site. Any maintenance or replacement of permitted
improvements, except for certain landscaping, which are beyond
"initial" improvements, shall be the homeowner's responsibility.
We agree to indemnify for ourselves, as well as for our
successors and assigns, and covenant and agree to hold
Association harmless from all claims, demands or liability
arising out of or encountered in connection with this Agreement,
whether such claims, demands or liability are caused by Owners,
Owners' agents or employees, or contractors or subcontractors
employed on the project, their agents or employees, or caused
by any products installed on the project by said contractor(s)
or subcontractor(s). Such indemnification shall extend to claims,
demands or liability for personal injuries and/or property damage
occurring during installation, as well as after completion,
including, but not limited to, all Owners' maintenance
responsibilities provided herein.
We further indemnify and hold the Association harmless from
all liability related to any damage to existing improvements
(wherever located within the Subdivision) resulting from the
installation/construction of the Architectural Improvement
If required by the Architectural Review Committee, we agree
to record, and pay for the recording, of this improvement at
the County Recorder's office.
We further acknowledge that the Architectural. Committee may
require a deposit be submitted before work is begun.
Rev. 4-96
t
Page Three
We further agree that this improvement will be completed in
a reasonable and diligent manner. We further agree that 1) if
we do not correct any damage caused as a result of implementation
of this improvement or, 2) if we fail to complete this
improvement within the allowed time frame the Homeowners
Association may elect to complete the work and/or repairs, and
we will be responsible for the actual costs of such work. Payment
to the Association is authorized by us in the form of an
assessment or monthly penalty payments as approved in the
Guidelines.
By signing this Agreement belo
terms and conditions and any
Architectural Committee in
Certificate, which is attached
a part hereof by this reference.
Situres of all 0:0ners:
(Signature)
Rev. 4-96
w, we agree to be bound by its
conditions set forth by the
the Architectural Committee
hereto as Exhibit "A" and made
(Signature)
ARCHITECTURAL COMMITTEE CERTIFICATE
(Exhibit "A" to the Architectural
Improvement Application and Agreement)
The Architectural Improvement Application and Agreement was
reviewed by the Architectural Committee on and has
been:
Approved Conditionally Approved Rejected
subject to the following
conditions set forth below
Returned for Further Information
Required Modifications
Comments
Yes No
Recording to be sent by owner to County Recorder's
office for roof and/or exterior wall modifications.
Deposit Required Deposit Amount Required $
Dat Architectural Committee
Architectural Commi_tteeA Architectural Committee
r/EVitectural Comm' ee Architectural Committee
NOTE: THIS APPROVAL IS VALID FOR 90 DAYS FROM APPROVAL DATE
Rev. 4-96
COMPLETION INSPECTION
Completed work inspected and approved Date:
Deposit return authorized (if applicable, and less any
reimbursement to the Association for costs incurred to bring
homeowner into compliance with the governing documents).
Recording verified.
Comments:
Signed: Date:
.Architectural Committee Chairperson
Rev. 4-96
1 # M 1.=
Free Design & Estimate
No WARPING -CHIPPING -PEELING -PAINTING Ever
Many
Sun
City
Installations
Serving
The
Desert
35 Years
ABOVE SUN CITY
ABOVE INDIAN RIDGE
Desert Patio Covers & Garden Rooms
Call Today - (760) 773-3172
Local - Licensed - Bonded - Insured
Lic #344248 - Shade Your Walls and Patio
/
41 71
L "va-Li-L- _L___1
l
® STANDARD FORM CONSTRUCTION AGREEMENT
all
16321 Mountain Mist St. DESERT PATIO COVERS AND GARDENROOMS
Riverside, CA 92503 BUILT BY MOUNTAIN MIST CONSTRUCTJQN COMPANY
(909) 687-6318 /) V
/ � t.i !t' '� Patio Covers / Z�
Gardenrooms,
40557 Clover Lane
Palm Desert, CA 92260
(760)773-3172
Modular Additions
Lie. # 620176 E -61-D03 Residential Remodeling Date Of Contract /r.: ,r''/ a`f
THIS DOCUMENT CONSISTING OF THIS AGREEMENT, PLANS, SPECIFICATIONS, AND "NOTICE TO OWNER",
ALL ATTACHED HERETO AND MADE A PART HEREOF, SHALL CONSTITUTE THE AGREEMENT.
Mountain Mist Construction Company, hereinafter called "Contractor", "Seller" and/or "Beneficiary" agrees to provide the following labor, materials and construction in
accordance with the,plans and specifications as may be added and initiated by the parties and attached hereto. /
Buyer(s)h y'� .°, f' 1 ! .� /i - ^�
•� Phonet/ ) �
? i !
Residence Add,/ss': ��� i t`-• I '••I �'• � � j. L �' l_. �- , !: , l � � rl.-� City / 4 /,� � r �.! 1 /4 Zip Code !• ,�- •�
J
Legal Description: Lot ( Tract '•" "- Book
Mr. S.S.#
Work Phone
Purchaser a`grccs to buy from Seller and Seller agrees to manufa5ture and install at th,
Page
County
Mrs. S.S. # Work Phone
ve installation address, the following:
IN PAYMENT AS FOLLOWS:
Total Cost 1. Finance Signing ..................... $ 6. Start of Roof .......... $
(Materials & Labor) ........................ $ %1%r4095 2. Pre -Construction Meeting ...... $ 7. Start of Walls ........ $
DEPOSIT, with Order .................... $ ej 3. Issuance of Permit ................. $ 8. $
f
4. Installation of Concrete .......... $ 9.
UNPAID BALANCE ........................ $ 5. Delivery of Materials .............. $ /,CC -2:-01 10. Completion.......... $ i
'Owner agrees that final payment is due upon completion of work. Paneling, drop ceiling, electrical, carpet and windows shall be considered within completion stage. Final
payment or completion certificate shall not be withheld pending building department inspection.
TIME FOR STARTING AND COMPLETING PROJECT: Work shall commence within ten days after the last to occur of the following: (1) Receipt by the Contractor of all
necessary building permits; (2) Receipt by the contractor of notice from Lender Lien Holder and/or Title Company (if any) that all documents required to be recorded prior to
commencement of construction have been properly recorded; (3) Owner has complied with all Terms and Conditions of the Agreemeos to at (� ) Receipt of all construction
funds by Escrow and Fund Control (if any). 1 ub)ect to,adiustment for the above conditions, work shall begin approximately on /-. r,*—J and be
substantially completed approximately on ( with additional time to be allowed as detailed in paragraph 20 of the Terms and Conditions on the
back hereof. Substantial Commencement of work shall be defined as
(Briefly describe type of work representing Commencement)
Contractor's failure to substantially commence work, without lawful excuse, within (20) days from the date specified above is a violation of the Contractors License Law.
NOTICE TO BUYER: (1) Do not sign this agreement before you read it or it if contains any blank spaces. (2) You are entitled to a completely filled in copy of this agreement.
Owner acknowledges that he has read and received a legible copy of this agreement signed by Contractor, including all terms and conditions on the reverse side, before any work
was done, and that he has read and received a legible copy of every document that Owner has signed during the negotiation. If Owner cancels this agreement after the right of
rescission has expired, and before commencement of construction, he shall pay Constructor the amount of expenses incurred to that date plus loss of profits.
CONTRACT PRICE AND MANNER OF PAYMENT: In consideration of materials, labor and services, Owner agrees to pay contract in cash sum of
DOLLARS ($-7 t (" 0 ), payable in progress payments, which do not include finance charges of any kind, according to the above schedule.
Overdue payments will bear interest at the maximum legally permissible rate. If any payments is not made when due, Contractor may keep the job idle until such time as all
payments due have been made. A failure of navmonr fnr a norin l ,� •^ --., •-- - - • "'
.-.372
t
ylElyElLL �
O
N VIlICE 2
� d
Ha.lt6'�V
0
TYPICAL POST/COLUMN®
BEAM SPLICESHALL OCCUR
ki
DIRECTLY OVER AN INTERIOR
POST. NOT PERMITTED O
2 — POST UNITS
1 6 1 Y 1/2-
I
H D M `-`-- I O W
I I UF OR
II
oI
I I
#14 SMS O TOP,
BOTTOM & 24"c/
MAX. BETWEEN
I F
I I
SIDEPLATE EACH
SIDE PERO
I3 SO. POST BETWEEN
SIDEPLATES PER O
BEAM TO POST CONN.
S14 SMS EACH SIDE
O TOP, BOTTOM do
24"c/c MAX.BETWEEN
SIDEPLATE TO COLUMN
3 —f14 SMS
EACH SIDE
2 1/2 -SO. X
GALV. STEEL
WASHER
®:m
PER QA U 'U' BRACKET PER U lP
(H=1 1/2% L=2 3/4
W=2 1/8' O 6"RAFTER,
W-3 1/8" O 8'RAFTER)
W/4 —#8 SMS TO RAFTER
& 2 —IM4 SMS TO BEAM
RAFTER
LATTICE TO RAFTER __@ TO BEAM CONNECTION 0.
6— B14 SMS
EACH SIDE
PLASTIC
8' BEAM PER
PLUGS,
O
TYPICAL i
SIDEPLATE EACH
SIDE PERO
3'SO. POST
PER O
FT's REAM CONNFCTTON l r 1
'_3'SO. COLVMNL
AND FOOTING 1 l
11 "11 1
SIDEPLATES EACH SIDE
J BOTTOM OF
3' X 8' BEAM
PER C9jUMN SCHEDULE
I4PER O EACH SIDE OF
ALTERNATE 4
Q0 2
I. POST X COLUMN PERO
RAFTER �W=1 1/2', H=1 1/2-
x
USE PER @(W = 3/4', H=3/4',
4
SIOEPLATES PER 2
(W-2 3/4'OR 3 1 ; H-3";
L=2 3/4 ) W/2 —#8 SMS TO
RAFTER & 2 —/14 SMS TO
BEAM
L=2') O TOP, BOTTOM & MID HEIGHT
W/2 —1/8'0 POP RIVETS EACH LEG.
SEE TABLE 'B'. DWG PPC -4
FOR REWIRED THICKNESS
/4 MIN. 3 1/2' MIN.
RAFTERS O 24"c c MAX.
(12,4'S TOTAL)
is smS rAnCAL
PER TABLES ORO}
g14 SMS AT TOP, BOTTOM
& 24'c/c MAX. BETWEEN.
SEE ALTERNATE ADJACENT
3"SQ. COLUMN PER o
I' MIN,
�� LATAE PER ®
0
A
0
A
TSIDUES POST AND
RAFSR PER TABLES
BEAM/
TYPICAL POST/COLUMN®
BEAM SPLICESHALL OCCUR
ki
DIRECTLY OVER AN INTERIOR
POST. NOT PERMITTED O
2 — POST UNITS
1 6 1 Y 1/2-
I
H D M `-`-- I O W
I I UF OR
II
oI
I I
#14 SMS O TOP,
BOTTOM & 24"c/
MAX. BETWEEN
I F
I I
SIDEPLATE EACH
SIDE PERO
I3 SO. POST BETWEEN
SIDEPLATES PER O
BEAM TO POST CONN.
S14 SMS EACH SIDE
O TOP, BOTTOM do
24"c/c MAX.BETWEEN
SIDEPLATE TO COLUMN
3 —f14 SMS
EACH SIDE
2 1/2 -SO. X
GALV. STEEL
WASHER
®:m
PER QA U 'U' BRACKET PER U lP
(H=1 1/2% L=2 3/4
W=2 1/8' O 6"RAFTER,
W-3 1/8" O 8'RAFTER)
W/4 —#8 SMS TO RAFTER
& 2 —IM4 SMS TO BEAM
RAFTER
LATTICE TO RAFTER __@ TO BEAM CONNECTION 0.
6— B14 SMS
EACH SIDE
PLASTIC
8' BEAM PER
PLUGS,
O
TYPICAL i
SIDEPLATE EACH
SIDE PERO
3'SO. POST
PER O
FT's REAM CONNFCTTON l r 1
'_3'SO. COLVMNL
AND FOOTING 1 l
11 "11 1
SIDEPLATES EACH SIDE
J BOTTOM OF
3' X 8' BEAM
PER C9jUMN SCHEDULE
RA (W=1 1/2', H=1 1/2',
L=6") W/2 -j8 SMS TO RAFTER
AND 2
Q0 2
I. POST X COLUMN PERO
SEE TABLE 'C"
.024'
U BRACKET
FOR EMBED DE
(W-2 3/4'OR 3 1 ; H-3";
DWG. PPC -4
L-2 3/4") PER
=9711 I _
/4 MIN. 3 1/2' MIN.
CONCRETE SLAB
5/8'0 EXPANSION BOLT
ICSO RECOGNIZED FOR 750#
TENSION.
ATTACHED UNIT �
POST AT STAR CONN 111
5— J14 SMS
EACH SIDE OF
'U' BRACKET
TO POST
X .046' COLUMN PER O I
SEEPOS/7�AT SLAB
DETAIL ( j) FOR
JPORTION NOT SHOWN
U BRACKET TO FOOTING
ANCHOR, SEE TABLE V.
DWG. PPC -4
BEA
TYPICAL
DNTINUOUS INSERT
ER,, BUTT
PUCE—DIRECTLY OVER
ITERIOR POST
NESTS U' BRACKETS
PER (W=3', H=1 1/8',
L-2 3/47.
SEE O FOR
PORTIONS NOT SHOWN
8" BEAM WITH
INSERT CONNECTION
rE PO4'3-SO. POST PERBLE "A", DWG. PPC -5
SIDEPLATES
jCONCRETE SLAB
IWHERE OCCURS
—�
T111 II _I�I_I I. u _r
iTi I �nIn,ITI
—r—r'.
2-1/2'SO. X 1/4' THICK 10
GALVANIZED STEEL PLATE o el b t
WASHER INSIDE 'U" BRACKET
3/8'0 X VLONG
i BOLT THRU POST SEE TABLE "A"
CONCRETE FOOTING IS DWG. PPC -5 FOR
A CUBE, SEE TABLE "A' N1�1N 3 LENCiN CONCRETE FOOTING
DWG. PPC -4 OR PPC -6 (SQUARE) DIMENSION
ATTACHED UNIT FOR SIZE FREESTANDING TYPE
POST AT FOOTING CONN.@ t POST AT FOOTING CONN.0
2x CONTINUOUS
DOUGLAS FIR
LEDGER. SAME
DEPTH AS RAFTERS.
— 7fl��O:l
RAFTER
CH A
2 — #12 X,1 1/2' WOOD
SCREWS EACH SIDE
ANGER TO LEDGER
2 — #8 sMs
EACH SIDE
/J
PER@ EACH SIDE OF
J BOTTOM OF
3' X 8' BEAM
KiV ItK
RA (W=1 1/2', H=1 1/2',
L=6") W/2 -j8 SMS TO RAFTER
I
Q0 2
& 2 —012 X 1 1/2' WOOD
U21IR
SCREWS TO LEDGER
HANGER O 6 -1/2 -
* ATTACH WOOD LEDGER TO HOUSE
JSIMPSON
RAFTERS & U26-2
O 8' RAFTERS
W/2 —#12 WOOD SCREWS O 16'c/c,
PENETRATE SOLID WOOD BACKING
1 1/2' MINIMUM
WALL CONNECTION
2 —q8
3'SQ. SMS
EACH SIDE
BOTTOM OF
INSERT BEAM
— — NESTEQ'U' BRACKETS
PER (x'
I II
I II
J BOTTOM OF
3' X 8' BEAM
II II
II
3P'ESOOPOST
R
I
TNSFRT SHTM lriJ
1
ICBO EVALUATION SERVICE INC. REPORT 1841P TEXAS ALUMINUM INDUSTRIES, INC.
2900 PATIO DRIVE HOUSTON, TEXAS 77017 (713)948-9000
DRAWN BY: SCALE: DRAWING DESCRIP71ON DRAWING NUMBER
THE PERGOLA PATIO COVER
R2D2 DATET. 20, 1995 ASHTON,VANNOW CE �1 & AssOc.,irlc. nETAII.4 PPC -2
1. ALUMINUM DESIGN STRESSES ARE PER THE LATEST EDITION OF THE UNIFORM BUILDING CODE
AND THE ALUMINUM CONSTRUCTION MANUAL
2. ALTERNATE ALUMINUM ALLOYS MAY BE SUBSTITUTED FOR THOSE SHOWN, PROVIDED THEY ARE
REGISTERED WITH THE ALUMINUM ASSOCIATION AND HAVE EQUAL, OR GREATER YIELD AND ULTIMATE
ED
STRENGTHS.
3. ALL CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2000 PSI. CONCRETE
SLAB SHALL HAVE 3 1/2- MINIMUM THICKNESS AND SHALL BE IN GOOD CONDITION.
4. ALL FOOTINGS SHALL BEAR ON FIRM, NATURAL, UNDISTURBED SOIL OR CERTIFIED FILL DESIGN VERTICAL
SOIL BEARING PRESSURE = 1000 PSF.
5. ALL STEEL MEMBERS §HALL BE HOT DIP GALVANIZED OR ELECTROPLATED AND CONFORM TO ASTM
SPEC. A-446 GRADE C .
6. ALUMINUM FASTENERS SHALL BE 2024-T4. ALL OTHER FASTENERS SHALL BE GALVANIZED, STAINLESS
STEEL OR CADMIUM PLATED. ALL BOLTS SHALL CONFORM TO ASTM SPEC. A-307 AND HAVE
STANDARD CUT PLATE WASHERS. HOLES FOR BOLTS SHALL BE BOLT DIAMETER PLUS 1/16 IN. MAXIMUM.
7. EXPANSION ANCHORS INTO CONCRETE SHALL BE ICBG EVALUATION SERVICE, INC., RECOGNIZED AND
FSJ"ONnLE�4 SHALL HAVE THE MINIMUM VALUES INDICATED IN TABLE "C". MINIMUM CONCRETE EDGE DISTANCE
IS SIX (6) INCHES.
8. EACH INSTALLATION SHALL BEAR AN IDENTIFYING TAG GIVING THE NAME AND ADDRESS OF THE
MANUFACTURER, DESIGN LOADS AND ENCLOSIBILITY.
9. ALL ITEMS PERTAINING TO EACH PARTICULAR INSTALLATION SHALL BE CIRCLED (i.e. PROJECTION,
QO p�01S)!q yp,
POST SPACING, FOOTING DETAIL, ETC.).
7469 10. LATTICE TYPE COVERS SHALL NOT BE ENCLOSED, FREESTANDING COVERS OF ALL TYPES
�o o� SHALL NOT BE ENCLOSED.
11. THE LATTICE TYPE STRUCTURES SHALL NOT BE COVERED WITH ANY TYPE OF SOLID MATERIAL AS THE
DESIGN LOADS HAVE ONLY BEEN APPLIED TO THE HORIZONTAL PROJECTED AREA OF THE LATTICE, RAFTERS,
BEAMS, ETC., PER I.C.B.O. CRITERIA.
THE PERGOLA PATIO COVER
3004-H36 ALUM.
BEAM/RAFTER 1
3004-H36 ALUM.
LATTICE
•W
.040' O 6063 -TS AND
= 3004-H36 ALUM.
.048" • STEEL
0
�a
TYPICAL '4 "BRACKET
3004—H36 ALUM.
RAFTER/SIDEPLATE 2
125' °D
CD
n
�D
20' '
6061-T6 ALUM.
BEAM INSERT Q
ICBG EVALUATION SERVICE INC. REPORT 1841P
DRAWN BY. R2D2 ' SCALE. NONE
20, 1995
ASHTON,VANCE ', & ASSOC.,INC.
3004-1436 2 ATTACHED COVERS
6063-T6 ALUM. OR A-446 GRADE 'C'
GALVANIZED STEEL B FREESTANDING
COVERS.
COLUMN/POST 3
.040* 0 3-T
AN ALUM.
_ .048' • STEEL
-----------
11 'L' 1�
/,^-N
TYPICA
--------
TYPICAL "U" BRACKET
TEXAS ALUMINUM INDUSTRIES, INC. mW
2900 PATIO DRIVE HOUSTON, TEXAS 77017 (713)946-9000
DESCRIPTION GENERAL NOTES, JDPAWMG
NU1®ER PPC_ 1
ISOKE TMC AND
PART DETAIIS
o
g ppegg=�o
oC9n��
��372
:6$
��pWEER.BJ
7 q�
� ykMNEIN �
YNNCE
ays
No.116•��
0
`F' �Jcc.��a •iY
`,;,i;; '`r,
£L M.
f''J'rONA1. E�4
• NUMBER IN PARENTHESIS IS SIZE OF CONCRETE CUBE FOOTING IN INCHES.
•• SEE TABLE 'B' BELOW FOR DESCRIPTION. THE FIRST NUMBER IS FOR POSTS THAT ARE 8'-0'
MAXIMUM IN HEIGHT. THE NUMBER IN PARENTHESIS IS FOR COLUMNS 8'-6' MAXIMUM
IN HEIGHT.
***SEE TRIBUTARY WIDTH TABLE, DRAWING PPC -3.
TABLE "B" : COLUMN SCHEDULE
TABLE
"A" MAXIMUM
Efi
COLUMN SPACING
Eo
3" SQ. X .024" CENTER COLUMN W/
2"X 6 1/2"X .032" SIDEPLATES •.
❑3
10 PSF LIVE LOAD, 70
MPH WIND LOAD
3" SQ. X .046" CENTER COLUMN W/
2"X 6 1/2"X .032" SIDEPLATES **.
MAXIMUM
MAXIMUM COLUMN SPACING
MIN. NUMBER OF COLUMNS
TRIBUTARY
X 8'
042' BEAM
3'X 8'
WANSERT
COLUMN TYPE **
2 2
WIDTH
AT SLAB
AT FTG. s
AT SLAB
AT FTG. •
9'-3'
10'-2 (15)
9'-3"
16'-2'(17")
6'-0"
13'-7'
13'-7" (16")
16'-8'
21'-8" (19")
2 (2)
2 (2)
2
9'-6' (15")
7'-0
12'-7
12'-7' 16"}
14 -3'
20'-0' 19'
-T(-2)
-T(-2)
2
8'-0"
11'-10"
ll' -10-(17-),12'-6'
14'-0'(18')
18'-9" (20'
2 2
2 2
2
RL2
9'-0"11'-1."
9'-0'
11'-2" (17")
11'-1"
17'-8" (20'
2 2
2 2
2
2
10'-O"
10'-0'
10'-7' (17
10'-O'
16'-9" (20'
2 2
2 2
2
11'-0"
9'-1'
10'-1' (18`)
9'-1'
16'-0" (21"
2 2
2 2
2 2
!-ML
12'-0"
8'-4"
9'=8' 18'
8'-4"
15'-4" (21")
2 2
2 2
2 2
2 2
2
10 PSF LIVE LOAD, 90
MPH WIND LOAD
6'-0'
9'-3"
6'-0"
13'-7"
13'-7'(19-),16'-8"
2
21'-8" (22'
2 2
2 2
2 2
2 2
7'-0"
12'-7"
12'-7' (19')
14'-3"
0'-0" (22'
2 (3)
2 2
2 (3)
2 2
8'-0"
11'-10"
11'-10' (19')
12'-6"
18'-9" (23'
2 (3)
2_J21
2 (3)
2 2
q. -O.11
-1`
11'-2 20')
-TI'-1
17 -8 23'
2 (3)
2 2
2 (3)
2 2
10'-O'
10 -0"
7' 20
10'-0'
16'-9" 23"
3 (4
2 (3)
3 (4)
2 (3)
ll' -O"
9'-1`
10'-1 (20')l
9'-1"
16'-0" (24'
3 (4)
. 2 (3)
3 (4)
2 (3)
12'-0'
8'-4"
9'-8" (21')
8'-4'
15'-4" (24'
3 (4)/'X%
23
(4)
2 (3)
4 2
10 PSF LIVE LOAD, 100 MPH WIND LOAD
2
4
6'-0
13'-7'
13'-7' 21'
15'-6"
9'-3"
2 (4
2 2
2 (4)
2 2
7'-0"
12'-6`
12'-7' 21'
13'-3'
'
3 (5
2 2
3 (5)
2 (2
8'-0"
11'-0'
11'-10" 21"
11'-7'
a(25-
3 (6)
2 (3)
3 (6)
2 (3)
9'-0"
9'-9"
it' -2' (22")
10'-4"
3
3 (6)
2 (3)
3 (6)
2 (3)
10'-0"
8'-10
10'-7 (22)
9'-4"
6 2
4 (7
2 (3)
4 (7
2 (3)
11'-0"
8'-0"
10'-1' 23)
8'-5"
12'-6"(23")
4 (-)
3 (4)
4 (-)
3 (4)
12'-0
7'-4"
1 9'-8" 23`)
7'-9"
15'-4" (26'A
4 (-)1
3 (4)1
4 1
3 (4)
11'-2'
10 PSF LIVE LOAD, 110 MPH WIND LOAD
3
- 2
6'-0
12'-8"
13'-7" 22
12'-8'
21'-8' (25`
3 (-)
2 (3)
3 (-)
2 (3)
7'-0"
10'-10'
12'-7` (22")
10'-10"
0'-0" (26'
4T--)—
-T-w -T(--)
7'-11"
-i-(-4)-
(4)8'-0"
81-0.
9'-6'
11'-10'(23")
9'-6"
18'-9" (26"
4 -
3 (4)4
-)
3 (4)
9'-0"
8'-5'
11'-2" (23')
8'-5"
17'-8" (27'
5 (-)
3 (5)
5 (-
3 (5)
10'-0'
7'-7'
10'-7' (23")
7'-7'
16'-9" (27`
5 (-)
3 (5)
- 3
5
11'-0"
6-11'
10'-i" (24")l
6'-11`
16'-0" (28'
6 (-
3 (5)
12'-6'(25")
5
12'-0"
6'-4'
1 9'-8' (24')
6'-4"
15'-4" (28"A
6 (-)
4 (6)
• NUMBER IN PARENTHESIS IS SIZE OF CONCRETE CUBE FOOTING IN INCHES.
•• SEE TABLE 'B' BELOW FOR DESCRIPTION. THE FIRST NUMBER IS FOR POSTS THAT ARE 8'-0'
MAXIMUM IN HEIGHT. THE NUMBER IN PARENTHESIS IS FOR COLUMNS 8'-6' MAXIMUM
IN HEIGHT.
***SEE TRIBUTARY WIDTH TABLE, DRAWING PPC -3.
TABLE "B" : COLUMN SCHEDULE
COLUMN
TYPE
COLUMN DESCRIPTION
Efi
3" SQ. X .024" CENTER COLUMN W/
2"X 6 1/2"X .024" SIDEPLATES *.
Eo
3" SQ. X .024" CENTER COLUMN W/
2"X 6 1/2"X .032" SIDEPLATES •.
❑3
3" SQ. X .046" CENTER COLUMN W/
2"X 6 1/2"X .024" SIDEPLATES **.
®
3" SQ. X .046" CENTER COLUMN W/
2"X 6 1/2"X .032" SIDEPLATES **.
• USE AT SLAB SUPPORTED UNITS ONLY.
•• USE AT SLAB SUPPORTED OR FOOTING SUPPORTED UNITS.
TABLE "C" : ANCHORAGE TO FOOTING
TABLE
"A" MAXIMUM
SIZE
COLUMN
SPACING
5/8"0 EXPANSION BOLT EMBEDDED 2-3/4 INCHES
MINIMUM 750 LB. TENSION).
20 PSF LIVE/SI;OW LQAD, 70 MPH WIND
LOAD
MINIMUM 1125 LB. TENSION).
MAXIMUM MAXIMUM COLUMN SPACING
TRIBUT AY 3• 3' WANSERT
WIDTH AT SLAB AT FTG. • AT SLAB AT FTG •
MIN. NUMBER OF COLUMNS
COLUMN TYPE ••
5'-0"
11'-2"
11'-3" (14"
11'-2'
17'-8"(16)
2
2 2
2
2
2
2 2
6'-0"•
9'-3'
10'-2 (15)
9'-3"
16'-2'(17")
2
2 2
2
2
2
2 2
T-0"
7'-11"
9'-6' (15")
7'-11`
147-11'(17")
2
2 2
2
2
2
2 2
8'-0'
W -it"
8'-10" (15'
6'-I1"
14'-0'(18')
2
2 2
(?1
2
2
2 2
9'-0'
6'-2'
8'-4" 16")
6'-2'
13'-2'(18")
2
2 2
2
2
2
2 2
10'-0'
5'-6"
7'-11" 16'
5'-6'
12'-6"(18')
2
2 2
2
2
2
2 2
14'-8'(18")
20 PSF LIVE/SNOW LOAD, 90 MPH WIND
LOAD
2
5'-0'
11'-2"
11'-3' 16"
11'-2'
17'-8"(19")
2
2 2
2
2
2
2 2
6'-0'
9'-3"
10'-2" 17")
9'-3"
16'-2"(20")
2
2 2
2
2
2
2 2
7'-0'
7'-11'
9'-6' (17")
7'-11"
14'-11"(20')
2
3 2
2
2
3
2 2
8'-0'
6'-11"
8'-10'gth�l
2
14'-0'(21')
2
3 2
2
2.(3)
30 PSF
2 2
9'-0"
6'-2"
8'-4" (13'-2
5'-0'
(21")
2
3 2
2
2
3
2 2
10'-0"
5'-6'
7'-71`
6'-5
12'-6' 21')
3
4 2
3
3
4
2 3
20 PSF LIVE/SNOW LOAD, 100 MPH WIND
LOAD
7'-11" 18"
5'-0`
11'-2"
11'-3" 18"
11'-2'
17'-8'(2l')
2
4 2
2
2
4
2 2
6'-0'
9'-3
10'-2 (19")
9'-3"
16'-2"(21')
2
4 2
2
2
4
2 2
7'-0'
7'-11"
9'-6' (19")
7'-11"
14'-11"(22')
3
5 2
2
3
5
2 2
8'-0'
6'-11"
8'-10" 20'
6'-11"
14'-O`(22")
3
6 2
3
3
6
2 3
9'-0"
6'-2"
8'-4' (20")
6'-2"
13'-2'(23')
3
6 2
3
3
6
2 3
10'-0"
5'-6'
7'-11" (20")
5'-6"
12'-6"(23")
4
7 2
3
4
7
2 3
4'-9'
20 PSF LIVE/SNOW, LOAD, 110 MPH WIND
LOAD
3
5'-0"
11'-2"
11'-3' (19')
11'-2'
17'-8'(22")
3
- 2
3
3
-
2 3
6'-0"
9'-3"
10'-2" (20')
9'-3'
16'-2"(23")
3
- 2
3
3
-
2 3
7'-0'
7'-11"
9'-6" (20')
7'-11"
14'-11'(23')
4
- 2
4
4
-
2 4
8'-0"
6'-11"
8 -10' 21'
6'-17'
14'-0 (24")
4
- 3
4
4
-
3 4
6'-2"
8'-4" (21")
6'-2'
13'-2'(24')
5
- 3
5
5
-
3 5
10'-0"
5'-6'
7'-11" 21'
S'-6'
12'-6'(25")
5
- 3
5
5
-
3 5
TABLE "C" : ANCHORAGE TO FOOTING
MAXIMU
ANCHOR DESCRUMON +
SIZE
COLUMN SPACING
20"
5/8"0 EXPANSION BOLT EMBEDDED 2-3/4 INCHES
MINIMUM 750 LB. TENSION).
23"
5/8"0 EXPANSION BOLT EMBEDDED 4 INCHES
MINIMUM 1125 LB. TENSION).
25"
5/8"0 EXPANSION BOLT EMBEDDED 7 INCHES
MINIMUM 1500 LB. TENSION).
28"
5/8"0 DEFORMED HEAD BOLT (HEX, SQUARE HEAD,
7'-8"
OR ANCHOR BOLT) EMBEDDED 6 INCHES MINIMUM. sa
• EXPANSION BOLTS SHALL BE HILTI KB -II CARBON STEEL PER ICBO ER 4627
OR ICBO EVALUATION SERVICE INC. RECOGNIZED EOUIVALENT WITH TENSION
VALUES AS INDICATED
•• THESE BOLTS MAY BE SUBSTITUTED FOR EXPANSION BOLTS SHOWN.
I
ICBO EVALUATION SERVICE INC. REPORT 1841P
THE P E R G U LA P AT I U C U V E R DRAWNR2D2 SCALE: NONE
ASHTON,VANCE 'o & ASSOC.,INC.
1995
TEXAS ALUMINUM INDUSTRIES, INC.
2900 PATIO DRIVE HOUSTON, TEXAS 77017 (713)946-9000
WING DESCR1PA70N DRAWING NIAEBER
ATTACHED COVER TABLES PPC -41
WITH LATTICE COVERING
TABLE
"A" MAXIMUM
COLUMN SPACING
30 PSF
SNOW LOAD,
70 MPH WIND
LOAD
MAXIMUM MAXIMUM COLUMN SPACING
TRIBUTARY ••
• g W
WIDTH ••• AT SLAB ATFTG, s AT SLAB AT FTG •
MIN. NUMBER OF COLUMNS
COLUMN TYPE ••
5'-0'
7'-8"
9'-4' 13")
7'-8"
14'-8"(15")
2
2 2
2
2 2
2 2
6 -0'
6'-5"
8'-6' 14"
-i '-5
T3 -r-5'(16')
2
2 2
2
2 2
2 2
7'-0'
5'-6"
7'-11' (14')
5'-6"
12'-5`(16')
2
2 2
2
2 2
2 2
8'-0'
4'-9"
7'-4" (14")
4'-9`
it' -7'(17')
2
2 2
2
2 2
2 2
9'-0"
4'-3'
6'-11" (15")
4'-3'
10'-11'(17")
2
2 2
2
2 2
2 2
30 PSF
SNOW LOAD,
90 MPH WIND
LOAD
5'-0`
T-8`
9'-4" (15")
7'-8"
14'-8'(18")
2
2H22
2
6'-0"
6'-5'
8'-6" (16")
6'-5'
13'-5'(18')
2
2
2
7'-0'
S'-6'7'-11"
(16")
5'-6'
12'-5'(19")
2
3
2
H22
8'-0"4'-9"
7'-4' (17")
4'-9'
11'-7' 19'
2
3
2
9'-0"4'-3`
6'-11" (17")
4'-3'
10'-11'(20')
2
3
2
30 PSF
SNOW LOAD,
100 MPH WIND LOAD
5'-0'
7-8'
9'-4' (17')
7'-8"
14'-8'(19')
2
4 2
2
2 4
2 2
6'-0'
6'-5
8 -6' (18"
6'-5"
13'-5 20
2
4 2
2
2g62
-7 �-0
5'-6"
7'-11" 18"
5'-6
12'-5 (21")
3
5 2
2
3
8'-O
4'-9'
7'-4" (18')
4'-9
11'-7 (21')
3
6 2
3
39'-0"4'-3'
6'-11' 19')
4'-3"
10'-11"(21
3
6 2
3
3
30 PSF
SNOW LOAD,
110 MPH WIND LOAD
5'-0'
7'-8'
9'-4" (18')
7'-8"
14'-8"(21)
3
- 2
3
3 -
2 3
6'-0
6'-5'
B'-6' 18
6'-5'
13'-5'(21")
3
- 2
3
3 -
2 3
7'-0"
5'-6'
7'-11'. 19')
5'-6'
12'-5'(22')
4
- 2
Wl
4 -1
2 4
8'-0"
4'-9'
T-4' (19")
4'-9'
11'-7" 22"
4-
3
4
4-
3 4
9'-O"
4'-3"
W-11" 20")
4'-3'
10'-11' 23'
5-
3
5
5-
3 5
• EXPANSION BOLTS SHALL BE HILTI KB -II CARBON STEEL PER ICBO ER 4627
OR ICBO EVALUATION SERVICE INC. RECOGNIZED EOUIVALENT WITH TENSION
VALUES AS INDICATED
•• THESE BOLTS MAY BE SUBSTITUTED FOR EXPANSION BOLTS SHOWN.
I
ICBO EVALUATION SERVICE INC. REPORT 1841P
THE P E R G U LA P AT I U C U V E R DRAWNR2D2 SCALE: NONE
ASHTON,VANCE 'o & ASSOC.,INC.
1995
TEXAS ALUMINUM INDUSTRIES, INC.
2900 PATIO DRIVE HOUSTON, TEXAS 77017 (713)946-9000
WING DESCR1PA70N DRAWING NIAEBER
ATTACHED COVER TABLES PPC -41
WITH LATTICE COVERING