Loading...
BRES2015-022978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: ROB PITCHFORD 77622 COUNTRY CLUB DR PALM DESERT, CA 92211 -1/ �"�'O%rwQulnrw COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BRES2015-0229 49981 CALLE ESTRELLA 658260032 SMITH / ADDITION AND REMODEL $23,698.00 p Q � AUG 17 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License ��:� / � se No.: 997936 Date Con OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Divisio of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for permit subjects the applicant to a civil penalty of not more than five hundred dolls ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to A owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/17/2015 Owner: JOHN LELAND 28 GARDEN PL BROOKLYN, NY 92253 Contractor: D & T REMODELING INC 44630 FRANKLIN COURT LA QUINTA, CA 92253 (760)218-6414 Llc. No.: 997936 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the wor hich this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'. compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 00 of the Labor Code, I sh ompl it those pr isio . 1 Date / Applica WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representativesf this city to enter upon the ab menti on d prope y J�pection purposes. Dat J Signature (Applicant or A FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forADDITION: $371.73 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 1.5 $105.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 0.75 $52.50 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BLDG CITY STAFF - PER HOUR: $157.50 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBU1LDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $24.66 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $10.16 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL.- NEW CONSTRUCTION: $227.71 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT _ PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # . CHECK # CLTD BY DESCRIPTION ACCOUNT' QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD. RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID, PAID DATE FURNACE PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT . QTY AMOUNT, PAID PAID DATE VENT FAN 101-0000-42402 0 $36.27 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $14.49 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for MECHANICAL: $205.46 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $72.54 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $72.54 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION -ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD. RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PLUMBING FEES: $205.52 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $87.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $69.60 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 Al $ eta ,}..:� `•��,..%-�.`p�� ".CJ� Y r + "� ' METHODS �+ - JEt.V.4u:i�..v. .ak:safi � �• RECEIPT # ' ` �a�Yr' ._A ....�i �. ��� ^_ 1' CHECK # �• f "CLTD BY' DESCRIPTION"° Fst s r�#h,��gA000UNTY`�i r QTY` r,�r AMOUNTF ��PAID, '�`��•'PAID6ATE REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $0.00 }h Sn,Y z dor, n t, PAIDBY�. Y�,METHOD i fi Sh <<� ' �.. % �sRECEIPT-#kr� CHECK#k ,e, .. GLTDBY•, Total Paid for REMODEL: $340.79 $0.00 �.. :�DESCRIPTIONY a= a� ; r'' t ,.". N aACCOUNT"r t QTY ;z y'AMOUNTz , fs�µ , PAID}*> PAID'DATE SMI - RESIDENTIAL 101-0000-20308 0 $3.08 $0.00 a: PAID BY 10, METHOD`§�..r�i�3frCHECK# i%i�d >G - -CLTDBY.; Total Paid for STRONG MOTION INSTRUMENTATION SMI: $3.08 $0.00 TOTALS:$0.00 • r I �r • r I a" T�•� �3 0� C�OF'Ft�'�6 Description: SMITH / ADDITION AND REMODEL Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: APPROVED Applied: 6/9/2015 SKH Approved: 8/11/2015 JJO Parcel No: 658260032 Site Address: 49981 CALLE ESTRELLA LA QUINTA,CA 92253 Subdivision: TR 14496-1 & INT IN COMMON AREAS Block: Lot: 98 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $23,698.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 506 SQ. FT. ADDITION AND INTERIOR REMODEL 1660 SQ. FT. ELEC, PLUMBING, AND MECH. WILL BE REVISED PER 2013 CRC CODES. Printed: Monday, August 17, 2015 2:42:40 PM 1 of 5 RWYS TEMS CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK COMMENTS FROM CONSULTANT JIM JOHNSON 6/24/2015 6/23/2015 RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT MARY FASANO 7/20/2015 7/21/2015 RETURNED FROM YOUNG STRUCTUAL NOT APPROVED RECEIVED REVISIONS REQUIRED PLAN CHECK PICKED UP PHILIP JUAREZ 7/22/2015 7/22/2015 ROB PITCHFORD PICKED UP. PLAN CHECK PICKED UP STEPHANIE KHATAMI 6/25/2015 6/25/2015 PICKED UP BY MR ROB PITCHFORD PLAN CHECK SENT TO KAY HENSEL 7/15/2015 7/15/2015 OUTSIDE PC PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 6/9/2015 6/11/2015 RECEIVED RESUBMITTAL PHILIP JUAREZ 7/15/2015 7/15/2015 PLANS RESUBMITTED GIVEN TO KAY. Printed: Monday, August 17, 2015 2:42:40 PM 1 of 5 RWYS TEMS RESUBMITTAL STEPHANIE KHATAMI 8/5/2015 8/5/2015 TELEPHONE CALL JIM JOHNSON 6/25/2015 6/25/2015 FINANCIAL CALLED ROB PITCHFORD TO IMFORM HIM PLANS ARE READY FOR CORRECTIONS. TELEPHONE CALL JIM JOHNSON 7/21/2015 7/21/2015 CALLED ROB PITCHFORD TO INFORM HIM OF CORRECTIONS TELEPHONE CALL JIM JOHNSON 7/22/2015 7/22/2015 DESCRIPTION CALLED ROB PITCHFORD TO PICK UP CORRECTIONS TELEPHONE CALL AMOUNT JIM JOHNSON 8/11/2015 RECEIPT # CHECK # 8/11/2015 PAID BY CALLED ROB PITCHFORD TO INFORM HIM PLANS ARE READY TO ISSUE ADDITION, EA 101-0000-42400 0 CONDITIONS $0.00 ADDITIONAL 500 SF CONTACTS ADDITION, EA NAME TYPE 0 NAME ADDRESSI CITY STATE ZIP PHONE . FAX : EMAIL APPLICANT ROB PITCHFORD 77622 COUNTRY CLUB DR PALM DESERT CA 92211 ( Printed: Monday, August 17, 2015 2:42:40 PM 2 of 5 RWYSTEMS FINANCIAL INFORMATION CL DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY ADDITION, EA 101-0000-42400 0 $62.36 $0.00 ADDITIONAL 500 SF ADDITION, EA 101-0000-42600 0 $17.40 $0.00 ADDITIONAL 500 SF PC ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $0.00 ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $0.00 PC Total Paid forADDITION: $371.73 $0.00 HOURLY PLAN CHECK - 101-0000-42600 1.5 $105.00 1 $0.00 YES Printed: Monday, August 17, 2015 2:42:40 PM 2 of 5 RWYSTEMS Printed: Monday, August 17, 2015 2:42:40 PM 3 of 5 RWY57EM5 CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK #, METHOD PAID BY BY HOURLY PLAN CHECK - 101-0000-42600 0.75 $52.50 $0.00 YES Total Paid forBLDG CITY STAFF - PER HOUR: $157.50 $0.00 BSAS SB1473 FEE I 101-0000-20306 1 0 1 $1.00 1 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: RESIDENTIAL, EA 101-0000-42403 0 $24.66 $0.00 ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $10.16 $0.00 ADDITION 1,000SF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 1,000SF RESIDENTIAL, FIRST 101-0000-426000 $47.86 $0.00 1,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 APPLIANCE 101-0000-42402 0 $12.09 $0.00 REPAIR/ALTERATION APPLIANCE 101-0000-42600 0 $4.83 $0.00 REPAIR/ALTERATION PC CONDENSER/COMPRES 101-0000-42402 0 $36.26 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $24.17 $0.00 SOR PC EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 FURNACE 101-0000-42402 0 $36.26 $0.00 FURNACE PC 101-0000-42600 0 $24.17 $0.00 VENT FAN 101-0000-42402 0 $36.27 $0.00 Printed: Monday, August 17, 2015 2:42:40 PM 3 of 5 RWY57EM5 DESCRIPTION ACCOUNT QTY T AMOUNT PAID PAID DATE 'RECEIPT # CHECK # METHOD PAID BY CLTD BY VENT FAN PC 101-0000-42600 0 $14.49 $0.00 Total Paid forMECHANICAL: $205.46 $0.00 FIXTURE/TRAP 101-0000-42401 0 $72.54 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $72.54 $0.00 GAS SYSTEM, 1-4 101-0000-42401 0 $12.09 $0.00 OUTLETS GAS SYSTEM, 1-4 101-0000-42600 0 $24.17 $0.00 OUTLETS PC WATER SYSTEM 101-0000-42401 0 $12.09 $0.00 INST/ALT/REP WATER SYSTEM 101-0000-42600 0 $12.09 $0.00 INST/ALT/REP PC Total Paid for PLUMBING FEES: $205.52 $0.00 REMODEL,EA 101-0000-42400 0 $87.00 $0.00 ADDITIONAL 5000 SF REMODEL, EA 101-0000-42600 0 $69.60 $0.00 ADDITIONAL 500 SF PC REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 REMODEL, FIRST 500 SF 101-0000-426000 $134.88 $0.00 PC Total Paid for REMODEL: $340.79 $0.00 SMI - RESIDENTIAL 101-0000-20308 0 $3.08 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $3.08 $0.00 TOTALS:00 Printed: Monday, August 17, 2015 2:42:40 PM 4 of 5 RWSYS7EMS FINAL" I BLD I I I I I Printed: Monday, August 17, 2015 2:42:40 PM 5 of 5 RWSYSTEMS PARENT PROJECTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC REVIEWS ANGELICA ZARCO STRUCTURAL CALCS.pdf REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES NON-STRUCTURAL - JIM JOHNSON 6/11/2015 6/23/2015 6/25/2015 REVISIONS REQUIRED ESTRELLA.docx 2 WK DOC 7/21/2015 JIM JOHNSON 49-981 CALLE 49-981 CALLE 0 STRUCTURAL - 2 WK KATHRYN SAMUELS 6/11/2015 6/23/2015 6/23/2015 REVISIONS REQUIRED DOC NON-STRUCTURAL - 1 WK JIM JOHNSON 7/16/2015 7/23/2015 7/21/2015 REVISIONS REQUIRED TITLE -24 NEEDS TO BE CLARIFIED STRUCTURAL -1 WK KATHRYN SAMUELS 7/21/2015 7/28/2015 7/21/2015 APPROVED NON-STRUCTURAL- JIM JOHNSON 8/5/2015 8/12/2015 8/11/2015 APPROVED KATHRYN SAMUELS STRUCTURAL 1 WK 0 TRANSMITTAL (2nd).pdf Printed: Monday, August 17, 2015 2:42:40 PM 5 of 5 RWSYSTEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/22/2015 ANGELICA ZARCO STRUCTURAL CALCS.pdf STRUCTURAL CALCS.pdf 0 DOC 6/25/2015 JIM JOHNSON 49-981 CALLE 49-981 CALLE 0 ESTRELLA.docx ESTRELLA.docx DOC 7/21/2015 JIM JOHNSON 49-981 CALLE 49-981 CALLE 0 ESTRELLA.docx ESTRELLA l.docx DOC 8/11/2015 JIM JOHNSON SCHOOL FEES BRES2015- SCHOOL FEES BRES201S- 0 0229.pdf 0229.pdf 2ND REVIEW - NEW CITY TRANSMITTAL DOC 7/20/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0229 0 TRANSMITTAL (2nd).pdf Printed: Monday, August 17, 2015 2:42:40 PM 5 of 5 RWSYSTEMS Bin #, 0� Qty of La Quinta Building 8z Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012. Building Permit Application an Tracking Sheet Permit # w5W5-,M Iq Project Address: 49n- �O f (-A,(,LC t22r,�� Owner's Name: Tm— (TY4 A. P. Number: 6se -Xco Address: 4q-96 I t5p4LE VELLA. Legal Description: City, ST-; Zip: LA- GE) (&CT% Contractor: 374 7 Telephone: Address: Project Description: City, ST, Zip: Tele phone:—r6o 726 6.4 4� ...................... CXJ f��r—�Lq OML State Lic. # City Linc. #.-. Designer: Address:777Z (r0U0r0)K&,--"5 City, ST, Zip: Telephone ..... ............ . ........ ........... . ........ .. X, ---struction Type: Occupancy: State Lic. Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Rr7 Sq. Ft.Zp AR>It� Stories: #Units: Telephone # of Contact Person: ;� Estimated Value of Project: Q 0(:: % APPLICANT: DO NOT WRITE BELOW THIS LINE 9 'Submittal Req'd Rec1d TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 21' Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees 0% KLUCIV I M.U-- A A eIA4& Total Permit Fees ��Z� s {-ru �i PAO V -p - J.0 I I V 41 w1.+ 1.0 CITY OF LA QUINTA ;OMMUNITY DEVELOPMEV 4- CERTIFICATE OF COMPLIANCE s Desert Sands Unified School District 47950 Dune Palms Road < 6ERMUDAOUNES r Date 8/17/15 La Quinta,.CA 92253 1A RANCHO MIRAGE d �— INDIANWELLS ti 31899 (760) 771-8515 PALM DIDESERT d IIO y Owner Stephen Smith APN # 658-260-032 Address 49981 Calle Estrella Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition - Street No. Correction Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 49981 Calle Estrella 221 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 CommentOriginal COC recorded as 49081 which did not exist in school site locator. I searched apn after D. Norblom left & found it was linked to 49981 vs 49081. Philip Juarez from city called later in day regarding error on their Cert. of Sq. Footage form. Emailinq this corrected COC to Divarez(Dla-quinta.orq on 8/18/15 Der his reauest. At the present time, the Desert Sands Unified School District does not coltectiees on garages carports, covered patios/walkways, ressidential additions un er 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 221 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Dennis Norblom Check No. Bank Name/Recipient of Certificate Telephone Funding Exempt BY Dr. Gary Rutherford Superintendent Fee collected lexemp�ed,tty S ar n -M bilvrey Payment Recd /f /v Over/Under NOTICE: Pursuant to Government Code Section 66020(d)(1),thi will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the da n which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 221 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Dennis Norblom Check No. Bank Name/Recipient of Certificate Telephone Funding Exempt BY Dr. Gary Rutherford Superintendent Fee collected /exempte by haro Mc Ivre fN- -- Payment Recd I$0.00 !°Over/Under Signature NOTICE: Pursuan to Government Code Section 66020(d)(1), thi will s rve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date o wh' h the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting I BUILDING ENERGY ANALYSIS REPORT PROJECT: Stephen Smith Residence 49-981 Calle Estrella La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club STE O Palm Desert, CA 92211 (760) 346-2856 Report Prepared by: Tim Scott Scott Design and Title 24, Inc,. 77085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT APPR VED Date: FOR CONST CTION 7/30/2015 DATE a / The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is 0 authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. 1 EneravPro 6.6 by EneravSoft User Number: 6712 ID: CERTIFJOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE r#OD Project me: Remodeled Residence C ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CF F-01 PaJF1 of 11 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Remodeled Residence 03 This building incorporates one or more Special Features shown' below 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDVIftZ-yr) 03 Project Location 49-981 Calle Estrella Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 20 12 Project Scope Addition and/or Alteration 13 21�* Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2175 15 A� Number of Zones 3 16 Slab Area (ft2) 2175 17W(v Number of Stories 1 18 Addition Cond. Floor Area 221 e165 Natural Gas Available Yes 20 Addition Slab Area (ft) 221 C21 Glazing Percentage (%) 23.6% AW COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown' below 06 A�� Registration Number: �►� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 ENERGY USE SUMMARY 045j 06 07 08 Energy Use (kTDVIftZ-yr) Sta d d Design Proposed Design Compliance Margin Percent Improvement Space Heating 12.70 12.59 0.11 0.9% Space Cooling ^11� 332.88 328.20 4.68 1.4% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heatingtv 10.97 10.79 0.18 1.6% Photovoltaic Offset �,' — 0.00 0.00 -- Compliance Energy Total �^�� 356.55 351.58 4.97 1.4% Registration Number: �►� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 CERTIFJOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IVOD CFF -01 Project Name: Remodeled Residence IC ulation Date/Time: 08:22, Thu, Jul 30, 2015 PaW2 of 11 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xm1 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Cathedral Ceiling HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • -- None — o Coling System Verifications: • -- None — HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None — ENERGY DESIGN RATING 4r This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as'domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. V Reference Energy Use ♦.1 Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 402.84 397.87 4.97 1.2% includes calculated Appliances and Miscellaneous Energy Use (AMEU) e� 4LV BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 d' Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Remodeled Residence 2175 v 1 3 3 3 1 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 CERTIFJPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project ame: Remodeled Residence C ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFF -01 Pa'X3 of 11 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 1660 9 DHW Sys 1 addition Conditioned HVAC2 221 9 DHW Sys 1 casita Conditioned HVAC new3 294 9 DHW Sys 1 OPAQUE SURFACES 01 02 03 04 jh,05 06 07 08 09 10 Name Zone Construction Azimuth�Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition 70d Wall ex residence R-13 Wall 7S0'4:0 50 682 78 90 Existing No 160d Wall ex residence R-13 Wall 162) 140 1386 122.5 90 Existing No 250d Wall ex residence R-13 Wall W. 230 882 98 90 Existing No NW Wall ex residence R-13 Wall 315 295 250 15 90 Existing No 340d Wall ex residence R-13 Wall 340 320 1386 90 Existing No Roof 3 residence Defaul: 1978 to present 1623.6 Existing No 70d Wall addition R-21 Wall (W.21.2Z,A) 70 50 200 90 New N/A 160d Wall addition R-21 Wall (W21 -.2z6.16) 160 140 200 46.9 90 New N/A S Wall addition R-21 Wall (W 2x6.16) 180 160 150 26.8 90 New N/A 250d Wall addition R-21 Wall;(W'21.2x6.16) 250 230 252 40 90 New N/A 340d Wall addition R-21 Waa11T(W21.2x6.16) 340 320 352 90 New N/A Roof 4 addition AT38 Roof Attic 221 New N/A 70d Wall ex 2 casita R-13 Wall 70 50 200 15 90 Existing No 160d Wall ex 2 casita 4 R-13 Wall 160 140 200 90 Existing No 250d Wall ex 2 casita R-13 Wall 250 230 252 25 90 Existing No W Wall ex casita R-13 Wall 270 250 150 48 90 Existing No 340d Wall ex 2 casita R-13 Wall 340 320 352 90 Existing No Roof 5 casita �^�` Default prior To 1978 285.2 Existing No ♦0 Registration Number: ,P'% Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:28 CERTIFIOe: Remodeled Residence C ulE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE #OD Project mation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFF -01 Pa'X4 of 11 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 06 07 08 09 10 11 1 12 13 Radiant Statu Verified Existing Name Construction Type Roof Reflectance Framin Barrier Verified s Condition Orientatio Area Skylight Roof Rise Roof Roof Reflectan Roof g Statu Existing Name Zone Type n (ft) Area (ft2) (x in 12) Pitch Tilt(deg) ce Emittance Factor s Condifion Roof residence Defaul: 1978 to _ specify - 36.5 1.2 3 0.25 14.04 0.1 0.85 0.1 Existin No Attic addition Attic Roofaddition presentl 3% 0.3 0.75 No Yes New No Attic casita Attic Roofcasita g � Roof 2 casita Default prior To specify - 8.9 8.8 3 0.25 14.04 0.1 0.85 0.1 Existin No ng_ 19781 g ATTIC 01 02 03 04 05 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise,Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Existi Attic residence Attic Roofresidence Ventilated 3 0.1 0.85 No No No �) ng Attic addition Attic Roofaddition Ventilated 3% 0.3 0.75 No Yes New No Attic casita Attic Roofcasita Ventilated � 0.1 0.85 No No Existi No ��3 ng_ e®� AP ♦ V� ♦r Registration Number- Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:28 CERTIFJPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I#OD Project ame: Remodeled Residence C culation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFSRF-01 Pa7'5 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 3x5 70d Wall ex (- specify -70) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 3x5 2 70d Wall ex (- specify -70) - -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 5x5 160d Wall ex (- specify -160) - -- 1 25.0 0.71 0.60 Insect Screen (default) Existing No ex 5x5 2 160d Wall ex (- specify -160) - -- 1 25.0 0.71 0.60 Insect Screen (default) Existing No . ex 3x5 3 160d Wall ex (- specify -160) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 3x5 4 160d Wall ex (- specify -160) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 7.5x5 160d Wall ex (- specify -160) - -- �J{!P 10.0 0.71 0.60 Insect Screen (default) Existing No alt 5x6.5 160d Wall ex (- specify -160) -- -- "Al 32.5 0.46 0.24 Insect Screen (default) Altered N/A all 5x8 250d Wall ex (- specify -250) - -- 1 40.0 0.46 0.24 Insect Screen (default) Altered N/A alt 5x8 2 250d Wall ex (- specify -250)- -- 1 40.0 0.46 0.24 Insect Screen (default) Altered N/A all 3x6 250d Wall ex (- specify -250) -- ,5- , 1 18.0 0.46 0.24 Insect Screen (default) Altered N/A alt 2.5x6 NW Wall ex (- specify -315)-- 1 15.0 0.46 0.24 Insect Screen (default) Altered N/A Skylight ex Roof (- specify --270) -- -- 1 1.2 0.55 0.55 None Existing No Skylight ex 2 Roof (- specify --270) - -- 1 8.8 0.55 0.55 None Existing No Skylight ex 3 Roof (- specify --270) -- �, -- 1 8.8 0.55 0.55 None Existing No Skylight ex 4 Roof (- specify --270) �'� -- 1 8.8 0.55 0.55 None Existing No Skylight ex 5 Roof (- specify --270) �!w -- 1 8.8 0.55 0.55 None Existing No new 3x6.7 160d Wall (- specify -160) 1 20.1 0.46 0.24 Insect Screen (default) New N/A new 4x67 160d Wall (- specify --160) j v -- -- 1 26.8 0.46 0.24 Insect Screen (default) New N/A new 4x6.7 S Wall (- specify -180) ,e -- -- 1 26.8 0.46 0.24 Insect Screen (default) New N/A new 8x5 250d Wall (- specify -256)'30'-- -- 1 40.0 0.46 0.24 Insect Screen (default) New N/A ex 3x5 5 70d Wall ex 2 (- specify- -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 5x5 3 250d Wall ex 2 (- specify --250) -- -- 1 25.0 0.71 0.60 Insect Screen (default) Existing No ex 6x8 W Wall ex (- specify -270) - -- 1 48.0 0.71 0.60 Insect Screen (default) Existing No Skylight ex 6 Roof 2 (,specify -270) -- -- 1 8.8 0.55 0.55 None Existing No Registration Number: t� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - MR -07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 CERTIFJW OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Cr Project ame: Remodeled Residence C ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFF -01 PaW6 of 11 DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition Door 70d Wall ex 48.0 0.50 Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:28 CERTIFjPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I#OD Project ame: Remodeled Residence C culation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFSRF-01 Pa of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity / Frame: no insul. 12x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofresidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. > Inside Finish: Gypsum Board • Cavity / Frame: R-11 / 2x4 • Roof Deck: Wood Siding/sheathing/decking Defaul: 1978 to presentl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. D.C. R 11 0.088 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall R-13 Exterior Walls Wood Framed Wall 2x4 @ 16 R 13 0.095 Siding/sheathing/decking • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord o�f RRoof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofaddition Attic Roofs Wood Framed Ceiling IV. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) �® • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall'' 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofcasita Attic Roofs Wood Framedeiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default prior To 1978 attic) Wood Famed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. P Inside Finish: Gypsum Board Cavity / Frame: R-11 / 2x4 • Roof Deck: Wood Siding/sheathing/decking Default prior To 19781 Cathedral Ceilings, Clood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.088 Roofing: Light Roof (Asphalt Shingle) '00 Registration Number: CA Building Energy Efficiency Stands - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 CERTIFPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD Project 'PE Remodeled Residence C culation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFSRF-01 Pa 8 of 11 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab residence 1660 175 None 0.8 No Existing No Covered Slab 2 addition 221 62 None 0.8 No New No Covered Slab 3 casita 294 72 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION b 01 02 zo 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required �� Not Required -- pA_ WATER HEATING SYSTEMS ��� w 01 02 03K�' 04 05 06 07 08 Name Heater Element Type ®v Tank Volume (gal) Energy Factor or Efficiency Solar Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas �t§mall Storage 50 Number of Fraction 0 Verified Existing Name System Type Distribution Type Water Heater Heaters N Status Condition DHW Sys 1 DHW Pipe Insulation, All Lin "S*' DHW Heater 1 1 Annual Existing No M WATER HEATERS �V 01 02 s 0` 04 05 06 07 08 Name Heater Element Type wank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas �t§mall Storage 50 0.61 EF 40000-Btu/hr 0 0 Ifto, WATER HEATING - HERS VERIFICATION .01, 01 02 0v 03 04 05 06 07 Recirculation with Recirculation with Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Manual Control Sensor Control DHW Sys 1^ n n/a n/a n/a n/a n/a .0 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 CERTIE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE OD Project ame: Remodeled Residence C culation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CF ARF -01 Pa 9of11 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 CntrlFurnace Fuel -fired central furnace 80 AFUE Heating System Cooling System 80 AFUE Heating Component 3 Cntrl Fa nr ace - Fuel -fired central furnace 80 AFUE HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 1660 Existing No Cooling System Component 1 Component 1 System 1 1 10 12 No HVAC2 Other Heating and Heating Yes Cooling No Air Distribution HVAC Fan 221 Existing No Cooling System Component 2 Component 2 System 2 2 HVAC new3 Other Heating and Cooling System Heating Component 3 Yes Cooling Component 3 No 'Air Distribution 3 HVAC Fan 3 294 Existing No ��System 4k� HVAC - HEATING SYSTEMS 01 02 01 ♦w02� 03 Name pQType Efficiency Heating Component 1 CntrlFurnace Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnraace - Fuel -fired central furnace 80 AFUE Heating Component 3 Cntrl Fa nr ace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS ♦411;�' 01 02 X69 04 05 06 07 Efficiency Multi -speed Name System Type ♦.� EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A system Cooling Component 2 DuctlessSplitAirCond - Ductless ' 10 12 No No N/A mini -split and multi -split heat A/;C i Cooling Component 3 DuctlessSplitAirCond Duc�ssY mini -split and multi -split heatawc 10 12 No No N/A ♦®4/ Registration Number: " CA Building Energy Efficiency Stan ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 CERTIFJOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project 'JOE Remodeled Residence Ca culation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xmi CF9RF-01 Pag 0 of 11 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Duct Leakage f Target (%) �� Verified Duct Location Verified Duct Design Return Supply Insulation Supply Duct Return Duct 61 0.52459 Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 2 specified) Air Distribution Air Distribution Ducts located in attic Sealed and tested 4.2 AtticF,��Attic None New No System System 3 3 -hers -dist ow HVAC DISTRIBUTION - HERS VERIFICATION �w M 01 02 03 �� 04 05 06 Name Duct Leakage Verification Duct Leakage f Target (%) �� Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist N/A WH Fan 2 61 0.52459 1 Air Distribution System 2 -hers -dist N/A — – — – Iv IAQ (Indoor Air Quality) FANS #AZ 01 02 03 04 05 Name IAQ CFM �� IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0`Default 0 Not Required O%N COOLING VENTILATION 01 �� 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 �S►v 61 0.52459 1 WH Fan 2 61 0.52459 1 WH Fan 3 ��/ 61 0.52459 1 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 CERTIF* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I#OD Project ame: Remodeled Residence Ca ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xm1 CFVF-01 Page CFV of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc, 7/30/2015 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State ip: Palm Desert, CA 92211 Phone: � (7 0) 200-4780 lito RESPONSIBLE PERSON'S DECLARATION STATEMENT w(_ I certify the following under penalty of perjury, under the laws of the State of California: oma% 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility forr"Re building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this CertificateCompliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Comp it ance are consistent with the information rovided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency�or b ' approval with this permit a Responsible Designer Name: 4t� igner Sign Robert A. Pitchford Company: � v v /�Robert Fev A. Pitchford Design and Drafting C1I Address: �� License: 77-622 Country Club STE.O �® City/State/Zip: `� - Phone: Palm Desert, CA 92211 A _ (760) 346-2856 - - Registration Number: t� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-07082015-744 HERS Provider: Report Generated at: 2015-07-30 08:23:28 • 1� L. RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Stephen Smith Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family 12 Existing+ Addition/Alteration Date 7/30/2015 Project Address 49-981 Calle Estrella La Quinta California Energy Climate Zone I CA Climate Zone 15 i Total Cond. Floor Area 2,175 Addition 221 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R 11 1,624 Existing Wall Wood Framed R 13 5,633 Existing Door Opaque Door no insulation 48 Existing Slab Unheated Slab -on -Grade no insulation 1,954 Perim = 247' Existing Demising Wood Framed R 13 723 New Roof Wood Framed Attic R38 221 Cool Roof New Wall Wood Framed R 21 1,040 New Slab Unheated Slab -on -Grade - no insulation 221 Perim = 62' New FENESTRATION Orientation Area(ft) I Total Area: 512 Glazing Percentage: 23.6 U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.46 Exterior Shades Status Skylight 1.2 0.550 0.55 none none None Existing Skylight 8.8 0.550 0.55 none none None Existing Skylight 8.8 0.550 0.55 none none None Existing Skylight 8.8 0.550 0.55 none none None Existing Skylight 8.8 0.550 0.55 none none None Existing Left (E) 45.0 0.710 0.60 none none Bug Screen Existing Rear (S) 90.0 0.710 0.60 none none Bug Screen Existing Rear (S) 32.5 0.460 0.24 none none Bug Screen Altered Right (W) 98.0 0.460 0.24 none none Bug Screen Altered Right (NIM 15.0 0.460 0.24 none none Bug Screen Altered Rear (S) 46.9 0.460 0.24 none none Bug Screen New Rear (S) 26.8 0.460 0.24 none none Bug Screen New Right (W) 40.0 0.460 0.24 none none Bug Screen New Skylight 8.8 0.550 0.55 none none None Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing 1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC Ducted Ducted Attic 4.2 Existing HVAC Ductless/ with Fan Ductless n/a n/a Existing HVAC new Ductless/ with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ene Pro 6.6 by EnemySoft User Number. 6712 RunCode: 2015-07-30708:23:46 /D: Pae 14 of 32 • C RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Stephen Smith Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/30/2015 Project Address 49-981 Calle Estrella La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,175 Addition 221 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R11 285 Existing FENESTRATION T Total Area: 512 Glazing Percentage: 23.6 % I New/Altered Average U -Factor: 0.46 Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades Status Right (tM 25.0 0.710 0.60 none none Bug Screen Existing Right (tq 48.0 0.710 0.60 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnemyPro 6.6 by EnemySoft User Number: 6712 RunCode: 2015-07-30708:23:46 /D: Pae 15 of 32 4 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the com /lance approach used. Exceptions may apply, Review the respective code section or more information. Building Envelope Measures: §110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §1 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-11 I (a). §110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §I 10.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the C172R. §110.8(1): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 1 10.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §I50.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §I50.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §I50.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 150.0 (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e) I A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §I50.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §I50.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §I50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in§150.Oh2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § I50.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A, §I50.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted.canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class Il vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § I50.0(n)l : space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §I50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §15 0.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §I50.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §I50.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § I50.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §I50.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency §110.4(a): Regulations; an on switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. r 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. §1 10.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §1 10.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. §110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §I50.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § I50.0(k)I B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply ' with the applicable provisions of 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §I50.0(k)IC: §130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kliz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §I50.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k) I F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). §I50.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. §I50.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). §I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer §I50.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in ' 150.0(k)2. §I50.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to §1 10.9, and complies with all other applicable requirements in §150.0(k)2. §I50.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only §I50.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. §I50.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and §I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 4 2013 Low -Rise Residential Mandatory Measures Summary 0 a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § I50.0(k)9B: following requirements: i. Shall comply with § I50.0(k)9A; or ii. Shall comply with the applicabie requirements in §110.9, $130.0, §130.2, §130.4, §140.7 and §141.0. §I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D '110.9, '130.0, shall comply with the applicable requirements in §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and.residential carports with a total of eight or more vehicles per site shall comply '130.4, with the applicable requirements in §110.9, §130.0, $130.2, §140.7 and §141.0. §I50.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined ' according to 130.0(c). §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for ' nonresidential garages in § 110.9 § 130.0, § 130. 1, § 130.4, 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § I 50.0(k) I 2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §I50.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §1 10.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through § 110.1D(e). §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §1 10.10(b) through §I 10.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §1 10.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. §I 10.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit §I 10.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § l 10.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". 0 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date tephen Smith Residence 7/30/2015 System Name Floor Area HVAC 1,660 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 4,908 Return Vented Lighting Return Air Ducts Return Fan Ventilation 249 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 40,071 2,371 730 41,744 Total Output Btuh 178,000 0 Output Btuh/s ft 107.2 3,398 2,966 Cooling System 0 0 Output perSystem 35,500 10,827 1,920 249 11,926 Total Output Btuh 71,000 0 4,291 0 Total Output Tons 5.9 3,398 2,966 Total Output Btuh/s ft 42.8 Total Output s ft/Ton 280.6 1 57,695 59,601 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 2,800 Existing HVAC 40,482 23,230 178,000 Airflow cfm/s ft 1.69 Airflow cfm/Ton 473.2 178,000 Jan 1 AM Outside Air % 8-9% Total Adjusted System Output 40,482 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 23,230 Aug 3 PM Outside Air cfm/s ft 0.15 ote: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF 67 OF 127 OF Q.' Outside Air 249 cfm Supply Fan Heating Coil 126 OF 2,800 cfm ROOM 71 OF Return Fan 71 of 72 OF 2,800 cfm COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/66°F 75/66°F 61/60°F O. c Outside Air c 249 cfm Supply I Fan Cooling Coil 62 / 61 OF 2,800 cfm 71.6% r7 7 -J ( ROOM Return Fan 71 /64°F 71 /64°F 70/I64°F 2,800 cfm Energ Pro 6.6 by Energ Soft User Number: 6712 RunCode: 2015-07-30708:23:46 /D: Page 20 of 32 4 if 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date 'tephen Smith Residence 7/30/2015 System Name Floor Area HVAC 221 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 482 6,071 Return Vented Lighting 0 Return Air Ducts 0 Return Fan 0 Ventilation F 33 1,482 Supply Fan 0 Supply Air Ducts 0 TOTAL SYSTEM LOAD 7,553 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 89,000 316 136 8,486 Total Output Btuh 89,000 Output Btuh/s ft 402.7 0 Cooling System 0 Output perSystem 35,500 460 33 1,623 Total Output Btuh 35,500 F 775 0 Total Output Tons 3.0 0 Total Output Btuh/s ft 160.6 Total Output s ft/Ton 74.7 110,109 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 Existing HVAC 19,100 11,143 89,000 Airflow cfm/s ft 6.33 Total Adjusted System Output 19,100 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 11,143 89,000 Aug 3 PM Jan 1 AM Airflow cfm/Ton 473.2 Outside Air % 2.4% Outside Air cfm/s ft 0.15 ote: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF 71 OF 131 OF Outside Air 33 cfm Supply Fan Heating Coil 131 ,F 1,400 cfm ROOM 72 OF Return Fan 72 OF 72 OF O 1,400 cfm COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71/62°F 71/62°F 58/58°F Outside Air c 33 cfm Supply Fan Cooling Coil 58 / 58 OF 1,400 cfm 63.6% ( ROOM kW Return Fan 110 4 70/62°F 70/62°F 0 70/62°F 1,400 cfm 3 Energ Pro 6.6 by Energ Soft User Number: 6712 Run Code: 2015-07-30708:23:46 /D: Page 21 of 32 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date tephen Smith Residence 7/30/2015 System Name Floor Area HVAC new 294 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,020 Return Vented Lighting Return Air Ducts Return Fan Ventilation 44 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 12,500 420 186 11,542 Total Output Btuh 89,000 0 Output Btuh/s ft 302.7 0 0 Cooling System 0 0 Output perSystem 35,500 1,971 583 44 2,159 Total Output Btuh 35,500 0 1,003 0 Total Output Tons 3.0 0 0 Total Output Btuh/s ft 120.7 Total Output s ftlTon 99.4 1 14,471 113,700 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 Existing HVAC 19,121 11,287 89,000 Airflow cfm/s ft 4.76 Airflow cfm/Ton 473.2 Outside Air % 3-2% Total Adjusted System Output 1 19,121 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 11,287 89,000 Aug 3P ml Jan 1 AM Outside Air cfm/s ft 0,15 ote: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF 71 OF 130 OF Outside Air 44 cfm Supply Fan Heating Coil 130 OF 1,400 cfm ROOM 72 OF Return Fan 72 of 72 OF 1,400 cfm COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 71/63°F 71/63°F 58/58°F ;0 Outside Air Arc 44 cfm Supply Fan Cooling Coil 58 / 58 OF 1,400 cfm 64.5% I ROOM i�► Return Fan - 70/62°F 70/62°F T ;�D 70/62°F 1,400 cfm EnergyPro 6.6 by EnergySoft User Number: 6712 RunCode: 2015-07-30708:23:46 /D: Page 22 of 32 • ROOM HEATING PEAK LOADS Project Name Stephen Smith Residence Date 7/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name altered residence Floor Area 1,660.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF c = _ = = = = a = = = = = = = = = = = = = = = = = = 46 Btu/hr Defaut 1978 to present 1,623.6 0.0790 46 5,900 Skylight 36.4 0.5500 46 921 R-13 Wall 4,272.5 0.0901 46 17,700 Wood Door 48.0 0.5000 46 1,104 Existing Window 120.0 0.7100 46 3,919 LowE METAL .46.24 145.5 0.4600 46 3,079 Slab -On -Grade perim = 175.0 0.7300 46 5,877 'R-13 Wall 511.0 0.0901 0 0 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,660 X Area another room 9.00 X 0.266 Height ACH Page Total /60] X AT 38,499 _ 3,244 TOTAL HOURLY HEAT LOSS FOR ROOM 41,744 EnergyPro 6.6 by EnergySoft User Number: 6712 RunCode: 2015-07-30708:23:46 /D: Page 26 of 32 • L-, ROOM HEATING PEAK LOADS Project Name Stephen Smith Residence Date 7/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name new addition Floor Area 221.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OT *F = = = = c = = = = = = = = - = = = = = = = = = = = = = 46 Btu/hr R-38 Roof Attic 221.0 0.0260 46 264 R-21 Wall (W.21.2x6.16) 1,040.3 0.0690 46 3,302 LowE METAL .46.24 113.7 0.4600 46 2,406 Slab -On -Grade perim = 62.0 0.7300 46 2,082 `R-13 Wall 212.0 0.0901 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 221 X Area another room 9.00 X 0.266 Height ACH Page Total /60] X AT 8,054 _ 432 TOTAL HOURLY HEAT LOSS FOR ROOM 8,486 EnergyPro 6.6 by EnergySoft User Number: 6712 RunCode: 2015-07-30708:23:46 /D: Page 27 of 32 C • ROOM HEATING PEAK LOADS Project Name Stephen Smith Residence Date 7/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name exist casita Floor Area 294.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F = = _ = _ _ = = = = = = = = = = = = = = = = = = = = 46 Btu/hr Default prior To 1978 285.2 0.0790 46 1,036 Skylight 8.8 0.5500 46 223 R-13 Wall 1,066.0 0.0901 46 4,416 Existing Window 88.0 0.7100 46 2,874 Slab -On -Grade perim = 72.0 0.7300 46 2,418 'R-13 Wall 294.0 0.0901 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.0o X 1.064 Schedule Air Sensible Fraction through an interior surface X 294 X Area another room 9.0o X o.2ss Height ACH Page Total /60] X AT 1 10,967 = 575 TOTAL HOURLY HEAT LOSS FOR ROOM 11,542 EnergyPro 6.6 by EnergySoft User Number: 6712 RunCode: 2015-07-30708:23:46 /D: Page 28 of 32 ME RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Stephen Smith Residence 7/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bu Opaque Surfaces Default 1978 to present R-13 Wall Wood Door R-13 Wall R-13 Wall R-13 Wall R-13 Wall 'R-13 Wall altered residence Outdoor Dry Bulb Temperature 1,660.0 ft2 Outdoor Wet Bulb Temperature 70 °F Outdoor Dailv Ranae: Orientation (tM (E) (E) (S) (tM (NtM (N) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,623.6 0.0790 56.0 604.0 0.0901 31.2 48.0 0.5000 31.2 1,263.5 0.0901 28.2 784.0 0.0901 32.1 235.0 0.0901 30.2 1,386.0 0.0901 29.0 511.0 0.0901 0.0 15.0 64.8 0.0 36.5 15.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fanactratinn Skylight ex Skylight ex Skylight ex Skylight ex Skylight ex ex 3x5 ex 3x5 ex 5x5 ex 5x5 Oriantatinn Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 32.1 1.2 106.5 0.0 32.1 8.8 106.5 0.0 32.1 8.8 106.5 0.0 32.1 8.8 106.5 0.0 32.1 8.8 106.5 0.0 36.5 15.0 64.8 0.0 36.5 15.0 64.8 0.0 36.5 25.0 42.7 0.01 36.5 25.0 42.7 Page Total 112 OF 78 OF 34 OF Btu/hr 7,183 1,698 749 3,211 2,267 640 3,620 0 19,369 btumr 128 937 937 937 937 972 972 1,067 1,067 7.95 Internal Gain Btulhr Occupants 5.0 Occupants X 245 Btuh/occ. Equipment 1,660 Floor Area X 0.50 w/sgft 2,! Infiltration: 1.064 X 0.94 X 68.47 X 42 = Air Sensible CFM ELA AT TOTAL'HOURLY SENSIBLE HEAT GAIN FOR ROOM 40,071 Latent Gain Btu/hr Occupants -7�15.0 Occupants X 155 Btuh/occ. = 772 Infiltration: 4,771 X 0.94 X 68.47 X 0.00523 = 1,599 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM EnerovPro 6.6 by EneravSoft User Number: 6712 RunCode: 2015-07-30708:23:46 ID: Paae 29 of 32 No RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Stephen Smith Residence ROOM INFORMATION DESIGN CONDITIONS Room Name altered residence Outdoor Dry Bulb Temperature Floor Area 1, 660.0 ftz Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: ue Surfaces Orientation 7/30/2015 Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration ex 3x5 ex 3x5 ex 7.5x5 alt 5x6.5 alt 5x8 alt 5x8 alt 3x6 alt 2.5x6 Orientation Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 36.5 15.0 42.7 0.0 36.5 15.0 42.7 0.0 36.5 10.0 42.7 0.0 18.1 32.5 20.6 0.0 18.1 40.0 31.3 0.0 18.1 40.0 31.3 0.0 18.1 18.0 31.3 0.0 18.1 15.0 25.8 I= Page Total 112 OF 78 OF 34 OF Btu/hr 0 Btu/hr 640 640 427 669 1,252 1,252 563 387 5, Internal Gain Btulhr Occupants 5 0 Occupants X 245 Btuh/occ. Equipment 1,660 Floor Area X 0.50 w/sgft 2,! Infiltration: 1.064 X 0.94 X 68.47 X 42 = C Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 40,071 Latent Gain Btu/hr Occupants 5 0 Occupants X 155 Btuh/occ. = 772 Infiltration: 4,771 X 0.94 X 68.47 X 0.00523 = 1,599 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name77/30/2015 ate Stephen Smith Residence ROOM INFORMATION DESIGN CONDITIONS Room Name new addition Outdoor Dry Bulb Temperature 112 OF Floor Area 221.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD� Btu/hr R-38 Roof Attic (W) 221.0 X 0.0260 X 56.0 = 322 R-21 Wall (W.21.2x6.16) (E) 200.0 X 0.0690 X 31.2 = 431 R-21 Wall (W.21.2x6.16) (S) 153.1 X 0.0690 X 28.2 = 298 R-21 Wall (W.21.2x6.16) (S) 123.2 X 0.0690 X 26.0 = 221 R-21 Wall (W.21.2x6.16) (tM 212.0 X 0.0690 X 32.1 = 470 R-21 Wall (W.21.2x6.16) (N) 352.0 X 0.0690 X 29.0 = 704 'R-13 Wall 212.0 X 0.0901 X 0.0 = 0 XX = X X = Page Total 2,446 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr new 3x6.7 (S) 0.01 X 18.1 + 20.1 X 20.6 = 414 new 067 (S) 0.0 X 18.1 + 26.8 X 20.6 = 552 new 06.7 (S) 0.0 X 18.1 + 26.8 X 18.2 = 487 new 8x5 (W) 0.0 X 18.1 + 40.0 X 31.3 = 1,252 X + X = X + X = X + X = X + X = X + I X = Page Total 2,70 Internal Gain Btu/hr Occupants 0 7 Occupants X 245 Btuh/occ.=L 162 Equipment 221 Floor Area X 0.50 w/sgft = 377 Infiltration: 1.064 X 0.94 X 9.12 X 42 = 381 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,071 Latent Gain Btu/hr Occupants 0 7 Occupants X 155 Btuh/occ. = 103 Infiltration: 4,771 X 0.94 X 9.12 X 0.00523 = 213 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 103 EnemyFro 6.6 by EnerqySoft User Number: 6712 RunCode: 2015-07-30T08:23:46 /D: Page 31 of 32 0 I- 7 C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Stephen Smith Residence 1 7/30/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name exist casita Outdoor Dry Bulb Temperature 112 OF Floor Area 294.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF, Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr Default prior To 1978 (W) 285.2 X 0.0790 X 56.0 = 1,262 R-13 Wall (E) 185.0 X 0.0901 X 31.2 = 520 R-13 Wall (S) 200.0 X 0.0901 X 28.2 = 508 R-13 Wall (W) 227.0 X 0.0901 X 32.1 = 656 R-13 Wall (tM 102.0 X 0.0901 X 33.0 = 303 R-13 Wall (N) 352.0 X 0.0901 X 29.0 = 919 'R-13 Wall 294.0 X 0.0901 X 0.0 = 0 X X = X I J X I= Page Total 1 4,169 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight ex (tom 0.0 X 32.1 + 8.8 X 106.5 = 937 ex 3x5 (E) 0.0 X 36.5 + 15.0 X 64.8 = 972 ex 5x5 (W) 0.0 X 36.5 + 25.0 X 69.4 = 1,736 ex 6x8 (W) 0.0 X 36.5 + 48.0 X 72.1 = 3,460 X + X = X + X = X + X = X + X = X + I X = Page Total 7,106 Internal Gain Btu/hr Occupants 0 9 Occupants X 245 Btuh/occ. = 216 Equipment 294 Floor Area X 0.50 w/sgft = 502 Infiltration: 1.064 X 0.94 X 12.13 X 42 = 507 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,500 Latent Gain Btu/hr Occupants 0 9 Occupants X 155 Btuh/occ. = 137 Infiltration: 4,771 X 0.94 X 12.13 X 0.00523 = 283 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM .137 Ene Pro 6.6 by EnerqySoft User Number: 6712 Run Code: 2015-07-30708:23:46 ID: Pace 32 of 12 CERTIF* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE COD Project ame: Remodeled Residence C Cation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CF3WF-01 Pa of 11 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Remodeled Residence 03 This building incorporates one or. more Special Features shown below 04 02 Calculation Description Title 24 Analysis 06 07 03 Project Location 49-981 Calle Estrella Standard Design 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 20 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 2175 15 Number of Zones 3 16 Slab Area (ft2) 2175 17 Number of Stories 1 18 Addition Cond. Floor Area 221 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 221 21 Glazing Percentage (%) 23.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance ENERGY USE SUMMARY 02 This building incorporates features that require field testing �and/or verification by a certified;HERS rater under the supervision of a CECapproved HERS provider. i.. 1A _. -4L[ ti s, Vz i. u u IX rr w ae t� 03 This building incorporates one or. more Special Features shown below 04 t N i` t Is %-'r V il t-./ L- i Registration Number: CA Building Energy Ef n M -1m:�c ZOm Z 1513918-000000-� Registration Date/Time: I Compliance Report Version - CF1R-07082015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-07-30 08:23:36 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use ( D -yr Standard Design Proposed Design Compliance Margin Percent Improvement Spac$ Hi4ting 00 C) 12.70 12.59 0.11 0.9% Spac' ooling -n — 332.88 328.20 4.68 1.4% IAO V ilation 0.00 0.00 0.00 0.0% Wate eating 10.97 10.79 0.18 1.6% Photov It dc Offset go -- 0.00 0.00 -- Complian qergy D 356.55 351.58 4.97 _1.4% Registration Number: CA Building Energy Ef n M -1m:�c ZOm Z 1513918-000000-� Registration Date/Time: I Compliance Report Version - CF1R-07082015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-07-30 08:23:36 CERTIFY OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD CFF -01 Project me: Remodeled Residence C ulation Date/Time: 08:22, Thu, Jul 30, 2015 PaIjin of 11 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Cathedral Ceiling HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • — None — Cooling System Verifications: • -- None — HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • —None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated`by'Title 24, Part 6 (such as -domestic consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. A It '� 11 � � ( �;, 02 Reference, -Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 0,1 2.84 f 397.87 4.97 1.2% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Remodeled Residence 2175 1 3 3 3 1 Registration Number: 215-AO1513918-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIF* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE POD Project ame: Remodeled Residence C lation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFF -01 Pa of 11 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 1660 9 DHW Sys.1 addition Conditioned HVAC2 221 9 DHW Sys 1 casita Conditioned HVAC new3 294 9 DHW Sys 1 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition 70d Wall ex residence R-13 Wall 70 50 682 78 90 Existing No 160d Wall ex residence R-13 Wall 160 140 1386 122.5 90 Existing No 250d Wall ex residence R-13 Wall 250 230 882 98 90 Existing No NW Wall ex residence R-13 Wall 315 295 250 15 90 Existing No 340d Wall ex residence `"` R-13 Wall' I L340 -, —X320 _ 1386 90 Existing No Roof residence` IkDefaul:c1978 6a6resent "— 0 t[1623.6( -'""" Existing No 70d Wall addition A 'R-`21'Wall'(W.2_1.2z6r16)— '° «70- "-50 At "� " 260 "` 90 New N/A 160d Wall addition N R'21 W611 (W.-2f.2x6 16) t' 1601 It ,►1 -140 t L..,4 200 M 46.9 90 New N/A S Wall addition R-21 Wall (W21.2x6.16) 180 160 150 26.8 90 New N/A 250d Wall addition R-21 Wall (W21.2x6.16) 250 230 252 40 90 New N/A 340d Wall addition R-21 Wall (W.21.2x6.16) 340 320 352 90 New N/A Roof 4 addition R-38 Roof Attic 221 New N/A 70d Wall ex 2 casita R-13 Wall 70 50 200 15 90 Existing No 160d Wall ex 2 casita R-13 Wall 160 140 200 90 Existing No 250d Wall ex 2 casita R-13 Wall 250 230 252 25 90 Existing No W Wall ex casita R-13 Wall 270 250 150 48 90 Existing No 340d Wall ex 2 casita R-13 Wall 340 320 352 90 Existing No Roof 5 casita Default prior To 1978 285.2 Existing No Registration Number: 215-A0151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEOD Project Name: Remodeled Residence Ca culation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFF -01 Pa 4of11 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 06 07 08 09 10 11 1 12 13 Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Statu s Verified Existing Condition Attic residence Attic Roofresidence Ventilated Roof 0.1 Framin No Verified Existi ng No Attic addition Orientatio Area Skylight Roof Rise Roof Roof Reflectan Roof g Statu Existing Name Zone Type n (ft2) Area (ft2) (x in 12) Pitch Tilt(deg) ce Emittance Factor s Condifion Roof residence Defaul: 1978 to specify - 36.5 1.2 3 0.25 14.04 0.1 0.85 0.1 Existin No presentl g Roof 2 casita Default prior To _ specify - 8.9 8.8 3 0.25 14.04 0.1 0.85 0.1 Existin No 19781 g ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Statu s Verified Existing Condition Attic residence Attic Roofresidence Ventilated 3 0.1 0.85 No No Existi ng No Attic addition Attic Roofaddition Ventilated 3 0.3 0.75 No Yes New No Attic casita Attic Roofcasita Ventilated/~ " -370:,1 0.85 No No Exi ti No ,sx iso HERS P'RC3VID1EER Registration Number: 215-AO151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIFI0 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE h&OD Project Name: Remodeled Residence Ca lation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xmi CF1F-01 P 3 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplie Height (ft) r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition ex 3x5 70d Wall ex (- specify -70) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 3x5 2 70d Wall ex ( specify -70) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 5x5 160d Wall ex (- specify -160) - -- 1 25.0 0.71 0.60 Insect Screen (default) Existing No ex 5x5 2 160d Wall ex (- specify -160) -- -- 1 25.0 0.71 0.60 Insect Screen (default) Existing No ex 3x5 3 160d Wall ex (- specify -160) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 3x5 4 160d Wall ex (- specify -160) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 7.5x5 160d Wall ex (- specify -160) -- -- 1 10.0 0.71 0.60 Insect Screen (default) Existing No alt 5x6.5 160d Wall ex (- specify -160) -- -- 1 32.5 0.46 0.24 Insect Screen (default) Altered N/A alt 5x8 250d Wall ex (- specify -250) -- -- 1 40.0 0.46 0.24 Insect Screen (default) Altered N/A alt 5x8 2 250d Wall ex (- specify -250) -- -- 1 40.0 0.46 0.24 Insect Screen (default) Altered N/A alt 3x6 250d Wall ex (- specify -250) -- -- 1 18.0 0.46 0.24 Insect Screen (default) Altered N/A all 2.5x6 NW Wall ex (-specify -315)' - � - 1_JF 15.0 0.46 0244 Insect Screen (default) Altered N/A Skylight ex Roof (- specify -270) - J if 'W 1 0 12 0.55 '0.55 None Existing No Skylight ex 2 Roof (- specify - 70) '" """ = `_ _ -- _ " 1 ` -8j8 IV `0.55 _ ' 0:55' None Existing No Skylight ex 3 Roof (- specify a270) f-1 C-'"iE -- ri 1 `8:8 1 10:55 C 0'55 None Existing No Skylight ex 4 Roof (- specify --270) -- -- 1 8.8 0.55 0.55 None Existing No Skylight ex 5 Roof (- specify --270) -- -- 1 8.8 0.55 0.55 None Existing No new 3x6.7 160d Wall (- specify -160) -- -- 1 20.1 0.46 0.24 Insect Screen (default) New N/A new 4x67 160d Wall (- specify -160) -- -- 1 26.8 0.46 0.24 Insect Screen (default) New N/A new 4x6.7 S Wall (- specify -180) -- -- 1 26.8 0.46 0.24 Insect Screen (default) New N/A new 8x5 250d Wall (- specify -250) -- -- 1 40.0 0.46 0.24 Insect Screen (default) New N/A ex 3x5 5 70d Wall ex 2 (- specify --70) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No ex 5x5 3 250d Wall ex 2 (- specify --250) -- - - 1 25.0 0.71 0.60 Insect Screen (default) Existing No ex 6x8 W Wall ex (- specify -270) - -- 1 48.0 0.71 0.60 Insect Screen (default) Existing No Skylight ex 6 Roof 2 (- specify -270) -- -- 1 8.8 0.55 0.55 None Existing No Registration Number: 215-A0151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIF10 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE POOD Project Name: Remodeled Residence C ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xmi CFF -01 Pa of 11 DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition Door 70d Wall ex 48.0 0.50 Existing No eInc �. ,;.two H E RS PROVIDER Registration Number: 215-A0151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIF OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE FOOD Project Name: Remodeled Residence C FOOD Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFF -01 PaIJ97 of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofresidence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 • Roof Deck: Wood Siding/sheathing/decking Defaul: 1978 to presentl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.088 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 • Exterior Finish: Wood R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/decking • Cavity/Frame: no insul. /2x4 Top Chrd r�� 294 Top'Chord of.Roof,Truss.@ 24#; Roof Deck. Wood Siding/sheathing/decking Attic Roofaddition Attic Roofs Wood Framed Ceiling- 11 �� # in. O.C.W�r L ,1 none r• r0.644 Roofing: Light Roof (Asphalt Shingle) < 1 / €1: Inside Finish: Gypsum Board Ceilings (below 1�.1� Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiliri4> 42x4 @ 16 in. O.C. n d ',R 38'-1 x:0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofcasita Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default prior To 1978 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Floor Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-11 / 2x4 • Roof Deck: Wood Siding/sheathing/decking Default prior To 19781 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.088 Roofing: Light Roof (Asphalt Shingle) Registration Number: 215-A0151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - MR -07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIFIO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Remodeled Residence ation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CF&F-01 PaW8 of 11 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab residence 1660 175 None 0.8 No Existing No Covered Slab 2 addition 221 62 None 0.8 No New No Covered Slab 3 casita 294 72 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type (rq'istrib� utionTypex ( i ¢ Ill !w.e Heater f Number of t( Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW PipeInsulation; All Lines"' ` " aDHW Heatef 1 0.61 EF Annual Existing No "N 8"-! F-- 11K "+. iMr 011t t P 1r E f ) t - M WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.61 EF 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a Registration Number: 215-A01513918-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE h OD Project ame: Remodeled Residence C ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xm1 CFF -01 Pa of 11 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating System Cooling System 80 AFUE Heating Component 3 CntrlFurnace; `Fuel-fred, centfal furnace 80 AFUE HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC1 Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 1660 Existing No DuctlessSplitAirCond - Ductless Cooling System Component 1 No Component 1 N/A System 1 1 HVAC2 Other Heating and Heating Yes Cooling N0 Air Distribution HVAC Fan 221 Existing No Cooling System Component 2 Component 2 System 2 2 HVAC new3 Other Heating and Heating Yes Cooling N0 Air Distribution HVAC Fan 294 Existing No Cooling System Component 3 Component 3 System 3 3 HVAC - HEATING SYSTEMS 01 02 "" 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 _ CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 3 CntrlFurnace; `Fuel-fred, centfal furnace 80 AFUE 9t I I--�I #; i; If 1rNN 11 -1 11 11 tE it HVAC - COOLING SYSTEMS `. 4 t: 'z=" I rt U U U c� ' u v u 1; 01 02 "" ,� ~ 03'�r {� �, 04 V,? OS 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A system Cooling Component 2 DuctlessSplitAirCond - Ductless 10 12 No No N/A mini -split and multi -split heat A/C Cooling Component 3 DuctlessSplitAirCond - Ductless 10 12 No No N/A mini -split and multi -split heat A/C Registration Number: 215•A0151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIFI* OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE P#OD Project Name: Remodeled Residence Ca ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xmi CF1.*F-01 Pag of 11 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Name Duct Leakage Verification Duct Leakage Target (%) Insulation Supply Duct Return Duct N/A I— Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 1 specified) Air Distribution Ducts located in attic Existing (not 4.2 Attic Attic None Existing No N/A System 2 specified) Air Distribution Air Distribution System 3 Ducts located in attic Sealed and tested 4.2 Attic Attic None New No System 3 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION �; } o 01 Q r03 +� - �; 04 05 Name IAQ CFM 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist N/A I— -- I— -- Air Distribution System 2 -hers -dist N/A p ="� r -r- r = �^� n -- — -- 10 . Ill ii ii 3 ice`_/ 11 saw 1! it -)% f% - IAQ (Indoor Air Quality) FANS �� `"tij �; } o 01 Q r03 +� - �; 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required COOLING VENTILATION 01 02 03 04 Name Cooling Vent CFM Cooling Vent Watts/CFM Number of Fans WH Fan 1 61 0.52459 1 WH Fan 2 61 0.52459 1 WH Fan 3 61 0.52459 1 Registration Number: 215-A0151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-07-30 08:23:36 CERTIFI OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Remodeled Residence Ca ulation Date/Time: 08:22, Thu, Jul 30, 2015 Calculation Description: Title 24 Analysis Input File Name: Smith-Pitchford-15.xml CFIWF-01 Pagel of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: T"`v''Z0Z2:- Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to -the enforcement agency, for approval with this.building permit application. Responsible Designer Name: �� �: L Responsible Designer Signature: Turv.�ce'i Tim Scott1;. , �:•-.��-- t " r� n# tli i Company: H E S P Dtte(Signed- Scott Design and Title 24, Inc. Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0151391B-000000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-07-30 08:23:36