11-0256 (RPL)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
11-00000256
Property Address:
60933 -FIRE BARREL DR
APN:
764-520-025- -
Application description:
POOL - RESIDENTIAL
Property Zoning:
MEDIUM HIGH DENSITY RES
Application valuation:
23000
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
EHRICH EDWARD T & DEBORAH
1301 AVIATION BLVD.
REDONDO BEACH, CA 90278
Contractor:
Applicant: Architect or Engineer'p ,g CLASSIC POOLS & SPAS
NAR 201i J 79461 40TH AVENUE
BERMUDA DUNES,.CA 92203
(760)345-8302
Lic. No.: 634338
►� � /� , • r � gay .a
��"C :lf�1'•
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
Lic Ise Cla s: C10 C53 cense No.: 634338
Date: � ontractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.l.
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 3/18/11
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier MANFCTR ALLIANC Policy Number 2010010117887Z
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so -as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwithccopply with those provisions. -
Datei, � D pplicant: a
WARNING: FAIL RE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation. '
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property fo sec ' urpose
7---:] Sig ure (Applicant or
3
LQPERMIT
Application Number . . . . . 11-00000256
Permit . . .
BLDG POOL PERMIT
Additional desc . .
Permit Fee . . . .
234.00
Plan Check Fee
152.10
Issue Date . . . .
Valuation . . .
. 23000
Expiration Date
9/14/11
Qty Unit Charge
Per
Extension
BASE
FEE
45.00
2.1.00 9.0000
--=-------------------------------------------------------------------------
THOU BLDG
2,001-25,000
189.00
Permit . . .
MECH POOL
Additional desc . .
Permit Fee . . . .
26.00
Plan Check Fee
6.50
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
9/14/11
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1.00 11.0000
----------------------------------------------------------------------------
EA MECH
FURNACE >100K
11.00
Permit . . .
ELEC POOL PERMIT -RES
Additional desc . .
Permit Fee . . . .
45.00
Plan Check Fee
11.25
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
9/14/11
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
1.00 30.0000
----------------------------------------------------------------------------
EA ELEC
PRIVATE SWIMMING POOL
30.00
Permit . . .
PLUMBING
Additional,desc .
Permit Fee . . . .
3.3.00
Plan Check Fee
8.25
Issue Date
Valuation . . .
. 0
Expiration Date .
. 9/14/11
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
2.00 6.0000
EA PLB
FIXTURE
12.00
1.00 3.0000
EA PLB
WATER INST/ALT/REP
3.00
1.00 3.0000
----------------------------------------------------------------------------
EA PLB
GAS PIPE 1-4 OUTLETS
3.00
Permit . . . .
WALL/FENCE
PERMIT
7
LQPERMIT
Application Number . . . . . 11-00000256
Permit . . . WALL/FENCE PERMIT
Additional desc .
Permit Fee . . . . 15.00 Plan Check Fee
.00
Issue Date . . . . Valuation . . .
. 240
Expiration Date . . 9/14/11
Qty Unit Charge Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
POOL/SPA, BBQ & 15 L.F. 4' SCREEN WALL,
CITY STANDARD. ALARMS/BARRIERS SHALL BE
IN PLACE AT PRE -PLASTER INSPECTION. 2010
CODES.
-----------------------------------------------------------------------------
Other Fees . . . . . . . BLDG STDS ADMIN (SB1473)
1.00
Fee summary Charged Paid Credited-
----------------------------------------
Due
------------------
Permit Fee Total 353.00 .00 .00
353.00
Plan Check Total 178.10 .00 .00
178.10
Other Fee Total 1.00 .00 .00
1.00
Grand Total 532.10 .00 .00
532.10
Bin #.City
of La Quints
Butfdrng at Safety DfWWon
P.O. Box 1504, 78-495 Cage Tampko
La Quanta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Pennrt #
Project Address: 66--Q33
owner's Name: (Rt'Cw
A. P. Number.
Address: 33 -. 1-Q V Y 2 e f
Legal Description::
Contractor. C hsw r c P00 (- s ,Q
City, ST, ZiP: I:4 i G1 ..d2 S 3
Telephone:
Address: 71— q6t 466 tff 96
Project Description:
City. ST, zip: 17A Vj CA • f? -2-0 3
00 C 4eu n S A
Telephone: 7(.b_
State Lic. #: City Lie. #; O102 z)
Gy( �,`•
Arch., FAV., Desigaw.
Address:
city, ST, tip:
Telephone:
State Lic. #: i, 3 3 8
Construction Type- Occupancy:
Project type (circle one): New Add'n Aker Repair Demo
Name of Contact Person: Re ^ R. �p (1 r•,'(; t,Q Z
Sq. Ft :
# Stories: # Units:
Telephone # of contact Person:
Estimated Value of Project ,3 • o D !V
APPLICANT: DO NOT WRITE BELOW THIS UNE
N
Submittal
RWd
Recd
TRACING
PERMIT FEES
Pian Sets
Plus Chan submitted
'Item Amont
Structural Coles.
Reviewed, ready for corrections
Plan Cheek Deposit
Truss Coles.
Called Contact Person
Plan Cbeek Balance .
Me 24 Cala.
Ph= picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading pian
2" Review, ready for corrections/issue
Electrical
Subeontaetor Lbt
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''+ Review, ready for correctious/rssue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks Appr
Date of permit Issue
Sehodl Fen
Total Permit Fees
List #
EXHIBIT A'- PAGE 3
TPJLOGY AT LA QU NTA MAINTENANCE ASSOCIATION 4
DESIGN REVIEW COMMITTEE APPLICATION
(Do Not Write Below Line. This is to Be Completed By Design Review Committee Only)
...........................................................................................................................................................................................
Received by the Design Review Committee: M 0, 4 -'L1 -E- 14 ?'
Date
Homeowner Address
'Me attached Application has been reviewed by the Desi Review Committee and its action is:
APPROVED (Initials & Date)
DISAPPROVED* (Initials & Date)
Incomplete'Submittal
Require Additional Information.
FJ er
���..9�t-a ��ST �-✓ ra � .
-Lo —l(
ri
CONDITIONAL APPROVAL (Initials & Date)
S Notes on plans
ee conditions of appNval check list
RETURNED TO APPLICANT/OWNER.
l
Date: Signature:
For the Design Review Committee
Final Inspection: ❑ Approved as submitted ❑ Disapproved (refer to attached comments)
Date: Signature:
For the Design Review Committee
* In the event plans and specifications submitted to the DRC are disapproved, Owner may appeal to the Board
of Directors by submitting a written request for appeal. The written request shall be submitted to the Board
not more than thirty (30) days following the final decision of the DRC.
TRILOGY AT LA QUINTA H.O.: Ej:LeA"
CONDITIONS OF APPROVAL
Property Address: U O " (33 J'1 rt,- 3AR-ft,C-:-1 DateReviewed: M ASF C d f.'7.o 1 j
Conditions
Your plans have been approved, provided that you meet the items checked below and all work is consistent with the
Of Approval
Design Guidelines dated April 20, 2005, contained in the TLQ>fA Handbook:
1
The patio cover material must be Alumnawood or other similar wood like construction. Roofing materials shall
match the roof material of the dwelling or be open wood lattice
2
The color of the patio cover matches the home's stucco, tri, accent, fascia or white.
3
Any patio cover or awning to be installed and attached to die home must be installed in such a manner that it
does not compromise the integrity of the water permeability of the home.
4
Due to the patio cover's size it must constructed with variable heights or must be constnrcted in two sections with
a separation in between
5
The size of the patio cover is limited to the size of the proposed patio slab.
6
The proposed retractable awning may not be a striped awning. It must be a neutral color that blends with the
home. Please submit a sample- of the fabric.
7
Obtain services of a state licensed professional for consultation.
8
Obtain necessary building permits from the city of La Quinta, meeting setback requirements per city code and
maintain the.existing drainage.
9
IMaintained positive drainage in accordance with the Trilogy Design Guidelines (Section 3.8).
10
The screen door must be the color. of the house stucco or be black.
11 .
If underground drainage is installed, the drain needs to terminate in the grass swale and be flush with the turf .
Pool, spa, fountain, and air conditioning equipment set backs must comply with City of La Quinti codes. All
X
12
equipment shall be located, screened, or recessed in a manner so as to not be viewable from any lot or street and
the noise from the equipment attenuated fro the adjacent property owners. Pool set backs are 6' for harscape
and 18" for water line.
13
IThe color of the proposed concrete is natural of a neutral tone.
Rear yard may not exceed 70% hardscape and must have a minimum of 30% softscape, measured from the rear
14
building face of wall to the side property lines.
15
Proposed planting meets with the Trilogy Rear Yard Minimum Planting Requirements standards and all plants
are included on the Revised Approved Plant List contained the Design Guidelines..
16
TThe proposed wall or iron work to match the existing developer retaining wall in material, style and color or shall
he the Frazee Paint color specified in the guidelines.
Replace block wall per Shea Homes standard block wall specification, if removing any portion of block wall to
17
gain access to rear or side yard (requires inspection of rebar before cap is installed).
18
1 Refer to Exhibit Tin the.Design Guidelines. (Block Wall Design).
X
19
JWhen work is completed, please submit Notice of Completion form attached!
20
Make sure rear yard property line pins (markers) remain during construction (applies to golf course lots only)
21
All contractors must meet the Association representative prior to commencing construction..
22
Resubmit showing drainage flow/plans.
X
23
See notes on plans (if any)
24
1
An independent irrigation controller must be used for the rear yard, it cannot be tied into the front yard.
Notes
1�7L�i-�7 �'LU�Z�-� l3� L.ft� ,P�4�/42-• /S .` T•'�NL�
6LZ 1,5 w L
H:IASSOCKTIONSI tv of W QukftWRWffECTURALIDRC F"Vnr"KM10rU ofAR"M
14
AREA SCHEDULE
POOL
590 5q. Ft.
POOL PERIMETER
133 Ln. R.
POOL GOPING
92 5q. Ft.
5PA
49 5q. Ft.
5PA PERIMETER
28 Ln. R.
5PA 5PILLWAY
II 4 Ln. Ft.
5PA GOPING
26 5q. Ft.
GOLORED GONGRETE POOL DEGK
855 5q. Ft.
4' HIGH 13LOGK WALL
155 Ln. Ft.
6A5 LINE
120 Ln. R.
RA15M BOND BEAM GAP
32 Ft.
POOL � SPA MATERIAL 5GHEFULE
I. POOL DECK COLOR CONCRETE, COLOR TO BE SELECTED
2. SPA STACK STONE SPILL WAY
3. SPA RAISED +15", WITH A LIGHT BROOM FINISH ON COLORED CONCRETE COPING
4. SPA WATERLINE TILE TO BE SELECTED (GAT#I)
5. POOL BENCH .
6. POOL WATER LINE TILE TO BE SELECTED. (GAT#I)
1. RAISED BOND BEAM +IS" WITH A LIGHT BROOM FIN15H ON COLORED CONCRETE COPING
8. Two, 18" WIDE SHEER DESCENTS ON RAISED BOND BEAM
q. RA15ED BOND BEAM TO HAVE STONE ON POOL SIDE, STONE TO BE SELECTED
10. RA15ED BOND BEAM TO HAVE STUCCO VENEER FIN15H ON THE BACK 51DE
11. POOL AND SPA TO HAVE PLASTER, COLOR TO BE SELECTED
12. TANNING -LEDGE TO BE Q" DEEP
13. TANNING LEDGE UMBRELLA SLEEVE
14. POOL LIGHT
15. 5PA LIGHT
Ib. STEP SIZE TO BE SELECTED
THESE PLANS, DRAiYINGS AND SPECIFICATIONS ARE NOT TO BE REPRODUCED,
CHANGED OR COPIED IN ANY FORM OR MANNER iYHATSOEVER WITHOUT THE S C A L E ; 1 / 8 a -1 / — O //
iliIT1TT[[TTT 9TiliTTT1T /TAITGIT- ALS Psi ♦ �' i . f /C" A f
'900
e"o
assic
gg� pooh / Spa
(160)=345=8302
LIC" C10 C53 "634338