06-2417 (SFD)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description
Property Zoning:
Application valuation:
Applicant:
06-00002417
61155 FIRE BARREL DR
764-280-999-71 -300235-
DWELLING - SINGLE FAMILY
MEDIUM HIGH DENSITY RES
242110
Tu!t440"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
SHEA LA QUINTA
C/O JEFF MCQUEEN
DETACHED 8800 N GAINEY CENTER 350
SCOTTSDALE, AZ 85258
A�ect or Engineer:
b5\Pr C(�J15J
22Q (46
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 000) o Division 3 of the Business and Professionals Code, and my License is in full force and effect.
Lic ns lass: License No.: 672285
Dat � ntractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that.) am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: N W,
Lender's Address:
LQPERMIT
Contractor:
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA, CA 92253
(760)777-6005
Lic. No.: 672285
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 6/16/06
D � D
JUN 2 9 2006
CITY OF LA QUINTA
FINANCE DEPT.
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier AMERICAN HOME Policy Number 1247619
I certify that, in the pe rmance of the work for whi this permit is issued, I shall not employ any
person in any mann so as to become subject to workers' compensation laws of California,
and agree that, if I ome ubj to the o kers' compensation provisions of Section
0 f t Labor s II fo with mpl se provisions.
D' atbJ��
pp".
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work isnot commenced
within 180 days from date of issuance of uch permit, or cessation of work for 180 dayswill subject
permit to cancellation.
certify th I have' a this application and state that ve infor atio corre agree to comply with all
city nd c my ord nances and state laws relating t u ing nstruc�3sh ere uthorize representatives
of t s cou on
the above-mentioned ope y for specties.
te: ature (Applicant or Ager
Application Number . . . 06-00002417
LQPERN11T
Structure Information
Construction Type . .
. . . TYPE V - NON RATED
Flood Zone
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION 2001 CBC
# BEDROOMS
4.00
FIRE SPRINKLERS NO
GARAGE SQ FTG
719.00
PATIO SQ FTG
322.00
NUMBER OF UNITS
1.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
2769.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
1140.00 Plan Check Fee
.741.00
Issue Date . . . .
Valuation . . . .
242110
Expiration Date
12/13/06
Qty Unit Charge
Per
Extension
BASE FEE
639.50
143.00 3.5000
----------------------------------------------------------------------------
THOU BLDG 100,001-500,000
500.50
Permit . . .
MECHANICAL
Additional desc . .
Permit Fee
90.00 Plan Check Fee
22.50
Issue Date . . . .
Valuation . . . .
0
Expiration Date
12/13/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 9.0000
EA MECH FURNACE <=100K
18.00
2.00 9.0000
EA MECH B/C <=3HP/100K BTU
18.00
5.00 6.5000
EA MECH'VENT FAN
32.50
1.00 6.5000
--------------------------------7-------------------------------------------
EA MECH EXHAUST HOOD
6.50
Permit . . .
ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee
126.30 Plan Check Fee
31.58
Issue Date . . . .
Valuation . . . .
0
Expiration Date
12/13/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2769.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
96.92
719.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
14.38
LQPERN11T
Application Number . . . . 06-00002417
Permit . . . PLUMBING
Additional desc . .
Permit Fee . . . . 171.00
Issue Date
Expiration Date 12/13/06
Plan Check Fee 39.75
Valuation 0
Qty
Unit Charge
Per
15.00
----------------------------------------------------------------------------
Special Notes and Comments
Extension
SFD - LOT 71 PLAN 6430C 2769/108 S.F
EXT. PATIO. PERMIT DOES NOT INCLUDE
BASE FEE
15.00-
5.0017.00
17.00
6.0000
EA
PLB
FIXTURE
102.00
1.00
15..00.00
EA
PLB
BUILDING SEWER
15.00
1.00
7.5000
EA
PLB
WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB
WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB
LAWN SPRINKLER SYSTEM
9.00
6.00
.7500
EA
PLB
GAS PIPE >=5
4.50
1.00
----------------------------------------------------------------------------
15.0000
EA
PLB
GAS METER
15.00
Permit .
Additional desc .
Permit Fee
Issue Date . . .
Expiration Date .
GRADING PERMIT
15..00
12/13/06
Plan Check Fee .00
Valuation 0
Qty Unit Charge Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
SFD - LOT 71 PLAN 6430C 2769/108 S.F
EXT. PATIO. PERMIT DOES NOT INCLUDE
BLOCK WALLS, POOL, SPA OR DRIVEWAY
APPROACH. 2001 CBC, CMC, CPC, 2004 CEC,
2005 ENERGY CODES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES
105.27
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
480.00
ENERGY REVIEW FEE
74.10
DIF FIRE PROTECTION -RES
140.00 .
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC - RES
892.00
STRONG MOTION (SMI) - RES
24.21
DIF STREET MAINT FAC -RES
67.00.
DIF TRANSPORTATION - RES
1666.00
Fee summary Charged Paid Credited
Due
LQPERMIT
Application Number
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
LQPERMIT
. . . . . 06-00002417
---------- ----------
1542.30
----------
.00
.00
----------
1542.30
834.83
.00
.00
834.83
3899.58
.00
.00
3899.58
6276.71
.00
.00
6276.71
f
JCM Inspections
39725 Garand Lane Suite F
' Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS
COMPRESSION STRENGTH TEST RESULTS
Client: Shea La, Quinta, LLC
Project: Trilogy @ La Quinta - Shea Homes
60-800 Triolgy Parkway
La Quinta, CA 92253
Date: 11127/06
Project No: 02-1109
Set ID Structure Age of Test Compression Strength
JCM ID Location Date Cast Cylinder ID (days) (psi)
Set A Phase 15D - Lot # 5071 Slab on Grade 7-24-06 Concrete
273-789 Family Room Required psi: 4000
4277
7
2670
4278
28
3870
4279
56
4210
4280
56
4280
CERTIFIED:
Page 1 of 1
- ' \Vs� �- - \1 V�
JCM Inspections supplies the service
of compression strength test results only.
Per ASTMC39
JCM Inspections
39725 Garand Lane Suite F
n , Palm Desert, CA 92211
r Phone: 760-345-5554 - Fax: 760-772-3895
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
60-800 Triolgy Parkway La Quinta, CA
�✓iIBC
_
� Title 24
other:
Client: Sub-Contractor:
Shea La Quinta, LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi
Slump (inches): !`Y s— Supplier: Superior
Time Sampled: Q�'� 3 nMix Design: D83625P
Time in Mixer (min.): s 5 Specified Strength (PSI): 4000
Water Added @ Jobsite (gals.): Addmixture: POZZ 322N
Q
Concrete Temperature (F): D6 Truck #: Ticket #:
Ambient Air Temperature (F): 1>11 Field ID Marking: Set A - 4 cylinders
Weather:
Unresolved Items:
PJ-None
❑ See Below
Location of Sample: syta , -% l.? CoAAx — �rn n. A%A
No Samples Taken
Description of Work Inspected: Phase D Lot# -SOF-1 , Product Plan& I � 30 G
r)
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SDD-1), Pad Footings and additional
rebar placed as per these details and as noted on — 'aj Et xi"c n
Also, typical details 2, 3/SD-1 and Notes on SN-1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx
A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes.
� ckp
1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx 1(n Verified correct mix design.
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications .applicable building laws. Final report issued at project completion.
Inspector: Jac C�Mlillin ICC Ce fi on No: 0842216-80
Contractor's Representative:
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I of
"JCM Inspections"
39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895
INSPECTIONS
PRESTRESSED CONCRETE INSPECTION REPORT Date:
Project Name:
Trilogy @ La Quinta - Shea Homes
Project No:
02-1109
Project Address:
60-800 Triolgy Parkway
City:
La Quinta, CA
Client: Sub -Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
General Contractor: Architect:
Shea Homes for Active Adults Bassenian Lagoni
Structural Engineer:
Borm & Associates, Inc./ Suncoast Post Tensi
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons
Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips
G q ea-, psi to 33.04 kips/33,000 lbs
Calibration Date: Machine # 31i:Z�
�%'
Phase "` Lot# S Product 's Plan � 3 ���� - G� •,���
❑✓ IBC
❑ Title 24
Other:
Unresolved Items:
®None
❑ See Below
Description of Work Inspected:
Specified
Lot # Location Tendons Elongation (in)
Actual Elongation (in)
Complies within 7% +/- of specified elongation.
Reference 11 h/SN2.
Yes No
3�,
❑
12 ❑
LA
QL�
V ❑
2 El
_
❑
n
'!
EZ ❑
Eir El
RA V n7
❑
`i
V ❑
❑ ❑
❑ ❑
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
Inspector: Jack C. Millin ICC Certification No: 0842216-89
Contractor's Representative:
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page h of
0
t .t :^.^i'-nxrt•�-1n�0. •"r,,ry�n;xvy.�q.,.'.,
-- -i "JI M'Inspections
39725 Garand Lane Suite F
i ' Palm Desert', CA 92211
L
INSPECTIONS Phone: 760-345-5554. - Fax: 760-772-3895
f
INSPECTIONS
EPDXY INSPECTION REPORT
Date:1_13.:(Y,,,
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
60-800 Triolgy Parkway La Quinta, CA
❑✓ IBC
❑Title 24
Other:
Client: Sub -Contractor:
Shea La Quinta, LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi
F `
a ® Anchor Bolts r ❑ Rebar
^� �,, � �
Epoxy Type: Snr. cAnn
J
Epoxy Shelf Life: Mo.► aM7,
Hole Cleaning Method(s): jK n ,, ,_, t \.c .x .n Ir %\�c N c pc V\
r
Weather:
� t.f1 i1 to
Unresolved Items:
❑u None
EJ see Below
Description of Work Inspected:
J
MC \ I\\ -Non G elf c+n U S \.+NC.l e +n.7lX� c� !, ✓'1 P Y i ! � .�,� � ,n.�f �'n '
\ nm
Ci C 0 r` � SD I C O rA ',:
EAC l* 1 Ti r% \..VKA. Q
�� ��+ c�"'1h• Ir� nre+ 4•�'). �n�F�1 [1�i� C flflf CO+\C� .
.\
Work complies with written approval from Structural Engineer and ICBO Evaluation Report #
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications _applicable building laws. Final report issued at project completion.
Inspector: Jack,C. Millif�n�j I(/C^C Certifc\atiY{on fN'o:0842216-49
I Contract i s Representative:
Copy 1 JCM Inspections Copy 2 Project Superintendent
V t{
Copy 3 Governing Agency Page I of ti
M
t s