Loading...
05-2166 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: r05-000021.66 Property Address: 81831 FIORI DEL DESERTO APN: 764-010-011-72 -30092 - Application description: DWELLING - SINGLE FAMILY Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 175041 Applicant: architect or Td!t 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: DR K. HOVNANIAN FORECAST HOMES 4240 E. JURUPA ST. STE. 402 DETACHED CHINO, CA 91710 D ca u D JUN 16 2005 CITY OF LA QUINTA FINANCE DEPT. Lic. No.:--------------- -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with „Section 7000) of Division 3 of the Business and Profession s Cot o and my i nse is in full force and effect. License Class: B Lice a No.: 92 88 Datl,a-traaor. 6 OWF,t.fLDEER DECLARATIONI hereby affirm under penalty of perjury that I am exom the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Contractor: K. HOVNANIAN FORECAST HOMES 4240 E. JURUPA STREET ONTARIO, CA 91761 (909)937-3270 Lic. No.: 700788 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 ------------------ WORKER'S COMPENSATION DECLARATION Date: 6/06/05 I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier ZURICH INS Policy Number WC343666302 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject the workers' compensation laws of California, and agree that, if Ishould ecome subject w kers' co pensation provisions of Section 3700 of the Labor Co shall forthwi pl ith tho visions_ . �dt — Applicant: WARNING: FAILURE TO SECURE WORKERS' C PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT -Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, a d reby authod representatives of thi county to enter upon the above-mentioned propert r or inspection r es ,-Cratj — ignature (Applicant or Agent) LQPERMIT Application Number . . . . . 05-00002166 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 905.50 Plan Check Fee 147.15 Issue Date . . . . Valuation 175041 Expiration Date 12/03/05 Qty Unit Charge Per Extension BASE FEE 639.50 76.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 266.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 77.00 Plan Check Fee 4.81 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/03/05 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9:0000 EA MECH B/C <=3HP/100K BTU 18.00 3.00 6.500'0 EA MECH VENT FAN 19.50 1.00 ---------------------------------------------------------------------------- 6.5.000 EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee 121.73 Plan Check Fee ,7.61 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/03/05 Qty Unit Charge Per Extension BASE FEE 15.00 2690.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 94.1.5 629.00 ---------------------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 12.58 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 155.25 Plan Check Fee 9.70 Issue Date Valuation . . . . - 0 Expiration Date 12/03/05 Qty Unit Charge Per Extension BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 Expiration Date . . 12/03/05 Qty Unit Charge Per Extension BASE FEE Application Number . . . . . 05-00002166 SFD - LOT 72, PLAN 1A Permit . . . . . . PLUMBING 3)PERMIT DOES Qty Unit Charge Per DRIVEWAY APPROACH. 75% Extension 1.00 7.5000 EA PLB WATER•HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9_0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 9.00 .7500 EA PLB GAS PIPE >=5 6.75 1.00 -------------=------------------------------ 15.0000 EA PLB GAS METER -------------------------------- 15.00 Permit . . . GRADING PERMIT 225.00 Additional desc . DIF PARKS/REC - RES 502.00 Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . DIF TRANSPORTATION - RES Valuation . . . . 0 Expiration Date . . 12/03/05 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 72, PLAN 1A ,2690 SF. (PATIO 3-665 SF,GARAGE 3)PERMIT DOES NOT INCLUDE POOL,SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 75% REDUCTION TO PLAN CHECK FEE DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE ---------------------------------------- Other Fees .-.. . . . ----------------------------------- . . . . ART IN PUBLIC PLACES -RES 20.00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 14.72 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 15.00 DIF.LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 17.50 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Permit Fee Total 1274.48 Plan Check Total 169.27 Other Fee Total 2472.22 Grand Total 3915.97 LQPERMIT Paid Credited Due .00 .00 1274.48 .00 .00 169.27 .00 .00 2472.22 .00 .00 3915.97 •1 �. Certificate of Occupancy s(P gum& imam �. OF I��9wJ Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 81-831 FIORI DEL DESERTO DR. Use classification: SINGLE FAMILY DWELLING Building Permit No.: 05-2166 Occupancy Group: R-1 Type of Construction: VN Land Use Zone: RL Owner of Building: K HOVANIAN FORECAST HOMES Address: 4240 E. JURUPA ST. #402 City, ST, ZIP: CHINO, CA. 91710 By: STEVE TRAXEL Date: 04-28-2006 Building Official POST IN A CONSPICUOUS PLACE SOUTHWEST INSPECTION AND TESTING INC. � 10826 S. Norwalk #A / Santa Fe Springs, CA 90670 � 562-941-2990 714-526-8441 Fax -562-946-0026 i | FIELD DATA ON TEST SPECIMENS | --- ASTM C31, C1381 C143, C1721 C1731 C231, C1064 --- ' CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 81-631 FLORES. LA QUINTA JOB #: 50132 DATE: 09/22/2005 | JOB NAME: PIAllA SERENA/LA QUINTA 97 PERMIT #: B05-2166 ISSUED BY: LA QUINTA ^ ARCHITECT: K.T.G.Y. GROUP ARCH INC. ENGINEER: ESI/FME INC. | CONTRACTOR: K. HOVNANIAN COMPANIES SUB CONTRACTOR: CAMPBELL CONCRETE OF CALIF. .___________________________ _________----- _________________________________ i LOCATION IN STRUCTURE: LOT SLAB ON GRADE / -----------------------------~--------------------------------------------------- � CONCRETE SUPPLIER: SUPERIOR RDY MX PLANT: COACHELLA MIX #: D815P ` TYPE OF CEMENT : V ADMIXTURE: 220-N POZZ TICKET #: 1061 � SLUMP : 4" -WATER ADDED: 5 GAL AIR TEMP: 91 F ' CONCRETE TEMP: 74 F MIXING TIME: 45 MIN TIME CAST: 8:30 AM __________________________________________________________________________ DATE CAST: 8/15/2005 RECEIVED AT LAB: 8/16/2005 __________________________________________________________________________ SPECIMENS MADE BY: S. LAVAU SPECIFIED PSI: 2500 __________________________________________________________________________ FIELD IDENTIFICATION| A | B | C | D \ E __________________________________________________________________________ LAB IDENTIFICATION : 514690 : 514690 : 514690 AGE DAYS : 7 : 28 : 28 DATE TEST : 8/22/2005 : 9/12/2005 : 9/12/2005 SIZE -IN. : 4 X 8 : 6.000X12 : 6.000X12 AREA-SQ.IN. : 12.56 : 28.27 : 28.27 CRUSH LOAD -LBS : 27460 : 82410 : 84810 | COMP-STR.-PSI. : 2190 : 2915 : 3000 � ' | H/D � CORR FACTOR � ' CORR.STR.-PSI TIME TESTED BREAK TYPE C.T.M. USED --------------------------------- ---- --=----------- REMARKS Ahony AT?�������_ ASTM C39, C1741 C192, C470, C617, C42 | COMPLIES: X DOES NOT COMPLY: � THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING SAMPLES CAST BY OTHERS: ' - � RENAN R � LAB. MA � ASTM C39 BREAKS A= cone B= con and split C= cone D=shear E=columnar May 08 06 03:04p Energy Calc Services 851-780-0558 p.5 CERTIFICATE, OF FIELD VERIFICATION AND DIACNOSI'1C TFST'ING, (furl l) CF -41k Pi:1 7 7,-1 Serena +l Nrojoct 11110 — _ Dato X1-83-I-Fiorilrk] 1hscrlo;Dr - _ Forccist lIonics JW Project-Ad�dr "wry Builder Name "� Scott Adams _ (909) 322-8953 1-S Builder Contact Telephone flan Number Tim Topham 951) 7807265 6 ter Telephone Sample Group Number 72 serf yin.$ig a ro Date Sample use Number Firm: Energy Calc Services Inc HERS Provider: Ci4F.F_RS Street Address: 16551 Mockingbird Cyn, Rd. _ City/State/Zip: Riverside CA 92504-9638 (topics to: I;gilcJe;r,•H1:'RS Provider HERS RATER COMPI,IANCCS S,rATFMENT The hoose was: ❑ '1•esled ❑ Approved as part ol-sample Ictilinp„ but was nut leslcd As the HERS rater providing diapttostic testing and field verification, I certify that the houses identified on this form comply with the lesled compliance rc(tuircmcnts as checked on this limn. El The insufller has provided a copy of Ch -6R ( Installation Certificate) ❑ Distribution system is gully ductal 0,e„ docs not use building; Cavil ics as plenum% or phillorm returns in lieu ol'ducls) ❑ Where cloth backed. rubber adhesive duct tape is installed, m.Lstic and draw bands arc used in combination with cloth hacked, rubber adhesive duel tape lu se:1I Icuks al duel connection,, ❑ MINIMUM RF.QIIIRFMrNTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CKEDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured DUCI 111-cssurirition Test Resulls (CUM (if, 25 Ila) valuox Test I..eakage Flow in CFM 11• Iain flow is c:+lculatcd as 400ctin/ton x number of tons enter calculated value here. If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow = Check Sox for Pass or Fail (Pass=6% or less) ❑ ❑ Pass Fail Q THERMOSTATIC EXPANSION VALVE„(TXV) or Commtr,.sion i rov(?q (!guivalent a Yes ❑ No Thermostatic Expansion Valve (or Commission approval c(lidvalrnt) is installed and Access is provided for inspection 191 ❑ Yes is a pass Pass Fail January 5, 2001 INSTALLATION C;��'Y'1 IC:A�. 9 (Prue I of 13) . Permis Number Site AddYM LaT ? d tarda. i' o jka it 4AUU10 s ea-dfrraro is rartb;roer so bo poatcd rs"bwit as into or ttvailbblo for oil uppr®priaie'Us"= ,rtforrt►�ttoo pts0�vif9ad Qa lla1B ibt7t3 }S t�galr rsl; 11GWCV ft Aso of Tbia % to pettivide tbo irttolY IkTtev in optiovwt.) ARer coraplMian,of 110A ivapecdM, a copy tnuat to prowi&d W the buiUNUS 44grpottoxrr (Upon vequost) sad tpt+ buiHdiaB owasnr at ;;t;wpl oy, per &Wd4m 113., 1036). us -49 tg Ega(Nrtetu ('•q4i� NRr, r,' 15(ArAdttcY DWI !)etc( ut ticaling Homing ty'INYB. t dGCvrttikdAtrrAaote IOCgIMttq! (RS�UP„of0.)' LtlCagtyn Pfyink Load GapsairY c.o'R�+w1P�n+ �twl'uyr t;coltaS Equip. c:tiu CeMiittad C4M%gMter riot >:ls391tlurY 1)ttc� Gap tY 'rYK (VAB.: UW1 bd& WWO sqd tds>3ttca,l (,"im, atc.Y' Gtsstien t)ttw Lustl �.; _. _.r....... ...._......- __ ... �. _� __.. .. _ V .... - 1. 1tl1td5 �{liCrilaN !I�l4P pt argot!! iGti 1, tttq UMdttrWPOL vUWt dtetr egtt 0CUt UMd above is: 1) is tic WWAI gqWpmvnx tttstallod. 2) equivalaat W Or moat cfPteitxtt than bast "aciSad itt the antgook of co mpUaamo (Form CF -IR) a0bs itW for cuzaplittrtca wisb Ift 19"'V Efikitney sa ndv* foot sa9ic nidal bail . wd 3) nqu>wut tbnr uvots or exceeds tbo approPialt raps it t$ f'W nauabcwvd devices (T3vm tut: AitaARMe 7cy 1 eaWallomv or Put 6)� Wimc +rpplicabi0, Com' � ^- Sigrw-1ure,Dow Su aoutrUCTOT 0 OR Gauatw Coat wtur (C'o. Nurrra) OR Ov"Ier C7laaiovTioa if Racir- a of Rated'' l'uat 6►fi- Cut -war u.awr CEC Cartifisd b1fi TYX (&A culdtiau, 1&""I laver UeW Vaiwe 69"YI Staudbyr Uatalutiou >;uu.Y ss Kf oast y r'yaa i4arwt B: M i A tr>plbar -.. - Paiotl+£- � C'Mttwl Trac Silo=* or S.Wbrj _ � �. ��� F'�ar amretl1l r tmurept (.a►sd itipaa ortrrira tbmtvr tttprtt u* 73=0 8ntl0Srlo a9eeParlt ft urawa sw b", pomp wrest *aasar., till UWSY Vwwr. for UW44 P%3ur* Waur LttitMi united ivputol faeAlir 1Lavr MOO MAO. list Rteovory FfftckaraY. 5tan7dby Leas srt,i Wed luput, F" Wuxi taitaoss go Wotor owe les, ix liarmvory•5�laiggtrp MW liMred ittpla. a• K'12 attWWA b Wlr► kW if M6044kry W Made Imam basoan %iib w avagy horororkm tbso U.58. 1•'avoLitt) & She~ Hta4 <: •A.'1 i'uumvs ar-d. showerht U lustallt dl are conited to the Cosnmis3ion. pursuant to Tiild Z4, Fdrt 6, Scetron 1 l 1. 1. lira arAuviS ld, verify thaw t guipt4Wu ASted Wwve ray yigu4mm W. i) rho ucturrl aquiprrat;DY. inslaDcd-* 2) 8quivalef t to or rnury OM%;ttget thop dtsr WPM t9W ib the Groote of camplianm (t?vM CF -1 R) Yttbmid'Cd for eorrpri3acc wish the '60O yAMIMck SAWd-anis fur n midmttW building,.; mad 31 oquipmonr tbitt, mccts air exc*cda the nporo'priAto ►•09tttttza 9[W Am mwmtktumd devkW (freta tura Ayplram-4 epcgency Re+Sm4laaas ur part 6), where applicable. 5i�rarwre, pyte �"'� 2(4'i To': Suildiag DepwtWMt -4ERS Pcovidar' (if applioabie) iiuitding Owner ac4ecuganty ltremlling Sze;t>r1tMC'101r (0). Mame) OR Gautral Cattttxaror (Co. Name) OR Ownor Cart7plianCS'F—or tr—s . Augtrat 2001 IT/Z0 3DVd 380NIS73 3J1b-1 S�S-j 9L£8bL9ZS6t TT:80 900Z/0i/90 05/08/2006 08:24 9096052958 KHOVNANIAN HOMES PAGE 06/12 05/02/.2006 15:55 FA)( PARAOONWHIMIA ® 005/011 INSULATION PE.RTIFICAT Thi6 is to certify that insulation has been installed In conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 61.831 MORI DEL DESERTO; LOT 72, PHASE 4, LA QUINTA, CA E LINOS: TYPE: BLOWS MANUFACTURER: Certainteed THICKNESS: R-38 TWYLS PE: BATTS MAUNFACTURER: Owens Corning THICKNESS: R-13 GENERAL CONTRACTOR: FORECAST HOMES LICENSE # BY: TITLE, PA AGO SCHMID BUILD G PRODUCTS A MASCO Campany LICENSE # 221517 TITLE: ACCOUNT REPRESENTIVE DATE: