Loading...
13-1463 (RR)• I P.O. BOX 1504 4^' VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 11/18/13 Application Number: 13-00001463 Owner: Property Address: 49040 CALLE FLORA JESSER KENNETH APN: 658-210-033- - - 49040 CALLE FLORA Application description: RE -ROOF LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL ( Application valuation: 20727 Contractor: Applicant: Architect or Engineer: WINKLE COMPANY, R.D. P.O. BOX 476 THOUSAND PALMS, CA 92 (76.)322:5144 Nov I8 Lic. No.: 688062 i� Yy CIFiNANe DEPT A LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. LicenseClass: C39 C46 L'cense o.: 688062 Date/—�'3 Contractor: . OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. �I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0000182-2013 1 certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with t se provisions. Dateff/� Applicant: WARNING: FAILURE TO WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for.a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes 7 W) Date: 11ySignature (Applicant or Agent): Application Number . . . 13-00001463 Permit . . . RE -ROOF Additional desc . Permit Fee . . . . 71.50 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 5/17/14 Qty Unit Charge Per Extension 1.00 48.6200 LS MISC RE -ROOF, 1ST 2000 SF 48.62 2.00 11.4400 EA . MISC RE -ROOF, ADDL 1000 SF 22.88 ----------------------------------'----_--------------------------------------- Special Notes and Comments REROOF WITH INSULATION THERMOPLASTIC POLYOLEFIN - [CRRC: 0628-00021 2010 CALIFORNIA ENERGY CODE. ------------- -------------------------------------------------------------- Other Fees . . . . . . . . . PLAN CHECK, RE -ROOF 97.24 Fee summary Charged Paid Credited ----------------- ---------- ---------- -------------------- Due Permit Fee Total 71.50 .00 .00 71.50 Plan Check Total .00 .�00 .00 .00 Other Fee Total 97.24 .00 .00 97.24 Grand Total 168.74 .Ob .00 168.74 LQPERMIT Bin.# city 0f 1+Q Q[llntd Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Perinit # Project Address: 49040 Calle Flora Owner's Name:. Jesser Residence A. P. Number. Address: 49040 Calle Flora Legal Description: City, ST, Zip. La Quinta CA. 92253 Contractor: R D Winkle co Telephone: ep Address: PO Box 476 Project Description: City, ST, Zip: Thousand Palms, CA. 92253 Re-Roof with 1ar� 60mil TPO Telephone: 760-322-5144 :• Existing Root Will be Recovered.with EPS State Lie. #:688062 City Lie. Arch., Engr., Designer. Address: City., ST, Zip: Telephone: "f State Lia #:zw" �:::..:ax ..: i:�,« Construction TYpe:Roofing Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Ryan A. Winkle Sq. Ft.: 4,500 # Stories: 1 # Units: Telephone # of Contact Person: Estimated Value of Project: 20,727.00 APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Cheek submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit, . Truss Cates. Called Contact Person Plan Check Balance Title 24 Cates. Pians picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan V Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE: '^' Review; ready for correctionstiissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr ' Date of permit issue School Fees Total Permit Fees 'W"W INKLOO ROOF 'CONSTRUCTOR S Tuesday, October 1, 2013 The Jesser Residence 49040 Calle Flora La Quinta, CA. 92253 Attn: Ms. Jamie Jesser Re: Re -Roof Low -Slope Roofing System This proposal is in regard to the above referenced project. We are proposing the new low - slope roofing system. We have provided two re -roofing options. Furnishings and installations will be as explained below; Thermoplastic Polyolefin (TPO) Roofing System Demolition & Clean Up: RDW will remove the existing gravel from low -slope roofing system. All exposed fasteners from the existing roofing system will be pulled from the substrate, this will give a cleaner surface for the preparations of the new roofing system and,will in sure that the old fasteners will not puncture the new material. All roofing debris on the ground will be swept up and the grounds will be rolled with a magnet to pick up any fasteners or metal scraps that had fallen during the demolition. RDW will dispose of all roofing waste. Board Insulation: RDW will supply and installed a single layer of I" rigid EPS board insulation. The board insulation will overlay the existing built-up roof. By overlaying the existing built-up roof the waste will be minimized and the new roofing system will maintain a class "A "fire rating. The EPS will provide a smooth surface for the new roofing system and will give additional insulation of approximately R-6 aged value. RDW will mechanically fasten the insulation to the substrate using 3" plates and 2" fasteners. The fasteners will be installed in an I-90 pattern giving a 90mph wind rating. Additional insulation will be added to standing water areas. This will help reduce standing water, not eliminate it. P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 SIN cam' R 00 f C 0 N S7 P U CT OR S Thermoplastic Polyolefin (TPO): This is a single ply mechanically attached roofing system. We will be installing a 60mil-reinforced membrane that will be 8' or 10' by 100' roll. This allows us to have less field seams and end lap seams than your typical built-up roofs. This is a sure weld membrane meaning that all seams are heat welded together, compared to either hot tar in a built up roof or an open flame used in torch on roofs. The field will be seamed with a robotic heat welder giving a continuous and consistent weld Details, such as flashings and corners will be welded by hand. Welds will then be checked with a probe. The product is much safer, cleaner, and does not produce any unpleasant odor when being installed Other positives to this roofing system are that the TPO membrane is highly reflective and helps reduce energy consumption cost, it will provide a long term resistance to the punishing ultraviolet rays we receive here in the western states. This system meets California Title 24 specifications. The TPO roofing system will be installed to the manufactures specifications. This roofing system meets the specifications for a Manufacture 20 year No Dollar Limit (NDL) Warranty. Flashings and Corner Details: All vent pipe flashings will receive a pre -manufactured TPO boot flashing, the collars will be sealed with cut off mastic and hose clamps. All inside and outside corner details will receive pre -manufactured non -reinforced TPO corners. All flashings and corners will be hand welded and check with probes. Polyurethane Foam: The surface will be primed at the rate of .33 - .50 gallons per 100 square feet with a Neoprime primer. Polyurethane is a spray application, it shall be applied at a thickness of I" (varies '/'). In this application 3 lbs. density foam will be used All urethane will be coated properly with two separate coats of an acrylic coating. Both base and top coats will consist of 2 gallons per 100 square feet giving a total of 4 gallons per 100 square feet While the application of the top coat is being performed #11 sized granules will be embedded into the wet surface at the rate of 50 lbs. per 100 square feet. The coating on all foamed vent pipes will be terminated approximately 2" above the foam. This will supply us self -terminating flashings and also giving a finished appearance. The building will gain an approximate R -value of R-7 in this section of the ceiling insulation. This roofing system if recoated approximately every ten - twelve years could last indefinitely. This roofing system meets or exceeds California title 24 specifications. P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 INKLEgra: ROOF CONSTRUCTOR S Sheet metal: RDW will supply and install the following sheet metal; Platform caps, Edge metal, Scuppers, T -Top vents and vent pipe flashings as needed. If other sheet metal is desired to be installed by RDW there will be an additional cost. Otherwise all other sheet metal is to be supplied by and installed by others. Equipment Removal and Reinstallation: All roof top AC units will be removed and reinstalled. All equipment platforms will be raised to a minimum of 6" from the substrate. All equipment platforms will receive a water barrier prior to the installation of the cap metal. The new cap metal will be constructed from 24 gauge galvanized sheet metal. Electrical Lines and Conduit: All the electrical to the equipment will be disconnected and reinstalled. Any lines not installed in conduit that are required will be re -ran into new conduit. Plumbing: All plumbing will be disconnected from the equipment and reinstalled. All damaged vent pipes above the substrate will be repaired. All plastic drainage lines from the equipment that are required to be copper will be replaced. We have provided an option for replacing all roof drains, overflow drains and expansion cup links. This is highly recommend by RDW, the existing drains are plastic and all overflow drains have been canceled. The existing expansion cup links are the ribbed rubber boots, these boots break very offend which result in major interior water damage. Roof Drains and Overflows Drains: For the Thermoplastic Polyolefin (TPO) roofing system, roof drains and overflow drains must be cast iron or copper with clamping rings. It is required that the TPO roofing system have clamping drains. During the installation of the new drains all visible expansion cup links will be replaced. This is included in the Thermoplastic Polyolefin (TPO) roofing system (option #1) Damaged Plywood & Fascia: Damaged plywood, board or other substrate will need to be replaced. Since we cannot see if there is any or how much damaged wood there is this is not included into the contract amount. RDW can remove and replace any damaged plywood sheeting at $ 65.00 per sheet plus the cost of roofing. Other substrates will be removed and replaced at a time and material based cost. P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 www INKLO: O ROOF CONSTRUCTOR S RDW Warranty: RDW will warranty the low -slope roofing system for a period of five years (S). If the roofing systems are annually maintained in a Roof Maintenance Program by R D Winkle Company during the applicable warranty period, the warranty for these roofing systems will be extended to ten years (10). Please see WORKMANSHIP, MATERIALS AND SYSTEMS WARRANTY for more information. Thermoplastic Polyolefin (TPO) Roofing System (Option #1): $ 20,727.00 Annual Roof Maintenance Program: $-k- - *An Additional Contract will be Provided for the Maintenance Program Approval By:. Signature:_ Respectfully Submitted, C � Ryan A. Winkle Supervisor/Estimator Date: P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 INSTALLATION CERTIFICATE: Residential Reroof CF -6R -ENV -01 Site Address: 49040 Calle Flora, La Ounita CA. 92253 Enforcement Agency: Permit Number: If more than one person has responsibilityfor installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures with check boxes are required to be checked to ensure the mandatory measures have been met. CEILING INSULATION Rigid: Brand Name: Batt or Blanket Type: Brand Name: Loose Fill Type: Thermal Resistance (R -Value): Spray Foam Type: Brand Name: Installed Actual Thickness (inches): Contractor's min installed weight/ftz Manufacturer's installed weight per square foot to achieve Thermal Resistance (R -Value): ❑ § 150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor. ❑ § 118(a): Insulation installed meets Standards for Insulating Material. ❑ § 150(8): Mandatory Vapor barrier installed in Climate Zones 14 or 16. lb ROOFING PRODUCTS (COOL ROOFS) §151O12 ❑ Check this box if the newly installed roof is exempted from the roofing product "Cool Roof' requirements as indicated on the CF-1R-Alt- Reroof form for this project. Otherwise fill in the table below. L Roof Slope Product Weight Aged Solar Thermal t CRRC Product ID Number < 2:12 > 2:12 < 51b/ft2 > Slb/ft2 Product Type2 Reflectance3'4 Emittance 0628-0002' 53 1 ❑ ❑ ❑ TPO ❑4 0.70 0.90 ❑ ❑ ❑ ❑ ❑4 I. CRRC-1 label information is available is on the package of the roofing product being installed and attach the CRRC label to this form. 2. Indicate the type of product is being used for the roof top, i.e. single -ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value frotn the same directory and use the equation (0.2+0.7(p; ;,;�t — 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance. 4. Check box if the Aged Reflectance is a calculated value using the equation above. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)4. Select the applicable coating: ❑ Aluminum -Pigmented Asphalt Roof Coating ❑ Cement -Based Roof Coating ❑ Other DECLARATION STATEMENT • I certify under penalty of perjury; under the laws of the State of California, the information provided on this form is true and correct. • I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). • I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. • I reviewed a copy of the Certificate of Compliance (CF -1R) form approved by the enforcement agency that identifies the specific requirements for the installation. I certify that the requirements detailed on the CF -1R that apply to the installation have been met. • I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) R D Winkle co. Responsible Person's Name: Respo ible Person's Sign Ryan A. Winkle CSLB License: Date Signed: f4gon With Company (Title): 688062 11-18-2013 2008 Residential Compliance Forms August 2009 IFind rated products - Cool Roof Rating Council 1 SEARCH RESULTS Selected filters Manufacturer: Carlisle Construction Materials Incorporated 11/18/13 11:54 AM PRINT EXPORT ALL PRODUCTS CRRC PROD. ID MANUFACTURER. BRAND PRODUCT TYPE COLOR I SOLAR REFLECTANCE THERMAL EMITTANCE SRI MORE MODEL INFO initial 3 year initial 3 year initial 3 year 0628-0002 Carlisle Construction Materials Membrane: Single Bright White 0.79 0.70 0.90 0.86 99 85 Incorporated: Sure -Weld Ply Thermoplastic TPO White and Thermoset Roofing COOL ROOF RATING COUNCIL 449 15th Street, Suite 200 Tel (866) 465-2523 Email: info a@coolroofs.orc) Oakland, CA 94612 Fax (510) 482-4421 http://coolroofs.org/products/results Page 1 of 1 EvaluationIMES Report QDLICC-ESIUL Dual Report Reissued August 1, 2012 Click on the logo to access ut_ Certification This report is subject to renewal October 1, 2014. www.icc-es.org 1 (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing l-400 1i.[0IA91*j CARLISLE SYNTEC PO BOX 7000 CARLISLE, PENNSYLVANIA 17013 (717) 245-7000 www.carlisle-syntec.com EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING MEMBRANES ADDITIONAL LISTEES: VERSICO POST OFFICE BOX 1289 CARLISLE, PA 17013 (800) 992-7663 MULE -HIDE PRODUCTS COMPANY, INC. 1195 PRINCE HALL DRIVE BELOIT, WISCONSIN 53511 (800) 786-1492 WEATHERBOND POST OFFICE BOX 251 PLAINFIELD, PENNSYLVANIA 17081 (866) 471-5125 KELLY COMPANY/2001'INC. 325 THOMASTON AVENUE WATERBURY, CONNECTICUT 06702 (203) 575-9220 1.0 EVALUATION SCOPE Compliance with the following codes: - ■ 2009 International Building Code® (IBC) , ■ 2009 International Residential Code® (IRC) ■ Other Codes (see Section 8.0) Properties evaluated: ■ Weather resistance ■ Roof covering fire classification ■ Wind uplift resistance ■ Impact resistance . 2.0 USES Carlisle ethylene , propylene diene monomer (EPDM), polyvinyl chloride (PVC) and thermoplastic polyolefin (TPO) single -ply roofing membranes are used as roof coverings in. adhered and mechanically fastened membrane roofing systems. 3.0 DESCRIPTION 3.1 General: The EPDM, PVC and TPO Membrane Roofing Systems described in this report consist of single -ply roofing membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or noncombustible deck. See Table 1 for Carlisle product trade names and corresponding product names for Mule -Hide Products Company, Inc., WeatherBond, Versico and Kelly Company/2001 Inc., the additional listees. 3.2 EPDM Membranes: 3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced EPDM membrane, 45 mils thick [0.045 inch (1.14 mm)]. 3.2.2 Sure -Seal FR: - Sure -Seal FR is a black, nonreinforced EPDM membrane with fire retardants. Available thicknesses range from 45 mils (0.045 inch [1.14 mm]) to 90 mils (0.090 inch [2.29 mm]). 3.2.3 Sure -White: Sure -White is a white, nonreinforced EPDM membrane. It is available in thicknesses of 60 mils [0.060 inch (1.52 mm)] and 90 mils [0.090 inch (2.29 mm)]. 3.2.4 Sure -Tough: Sure -Tough is a black, reinforced membrane consisting of a. polyester reinforcement encapsulated between two EPDM membrane plies. A is available in thicknesses ranging from 45 mils [0.045 inch (1.14 mm)] to 75 mils [0.075 inch (1.90 mm)]. 3.2.5 Sure -Tough FR: Sure -Tough FR is a black, reinforced membrane consisting of a polyester reinforcement encapsulated between two EPDM membrane plies with fire retardants. Available thicknesses are 45 mils [0.045 inch (1.14 mm)] and 60 mils [0.060 inch (1.52 mm)]. 3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is a 45 -mil to 90 -mil [0.045 inch to 0.090 inch (1.14 mm to 2.29 mm)] non -reinforced EPDM bonded to a 5.5 -ounce - *Revised September 2013 1CC ESEvaluation Reports are not to be construed as represeming aenaherics or any other wribuies iron sp< cifuall), addressed, nor are rhes to be catsirued 'p N as an errda setpertt oj'tltr suAiect of rlle.report,or� a.reContntet }dationfor its use. Vrere is no a arrancy ky ICC Evaluation Service, LLC, express or implied, as h per -square -yard (0.18 kg /M2) polyester fleece. Available product thicknesses range from 100 mils [0.100 inch (2.55 mm)] to 145 mils [0.145 inch (3.68 mm)]. 3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK is a 45-, 60- or 90 -mil [0.045, 0.060 or 0.090 inch (1.14, 1.52 or 2.29 mm)] nonreinforced white EPDM bonded to a 5.5 -ounce -per -square -yard (0.18 kg/m2) polyester fleece. Available product thicknesses are 100, 115 and 145 mils [0.100, 0.115 or 0.145 inch (2.54, 2.92, or 3.68 mm)]. 3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45 -mil [0.045 inch (1.14 mm) or 60 -mil [0.060 inch (1.52 mm)] non -reinforced EPDM bonded to a 7.5 -ounce -per -square - yard (0.25 kg/m2) polyester fleece. Available thicknesses are 90 mils [0.090 inch (2.29 mm)] and 105 mils [0.105 inch (2.67 mm)]. 3.3 PVC Membranes: 3.3.1 Sure -Flex and Sure -Flex KEE: Sure -Flex and Sure -Flex KEE are membranes consisting of a polyester reinforcement encapsulated between two plies of PVC. The membrane is available in white,.gray, tan and custom colors. Available thicknesses range from 50 mils [0.050 inch (1.27 mm)] to 80 mils [0.080 inch (2.03 mm)]. 3.3.2 Sure -Flex FRS: Sure -Flex FRS membrane consists of a fiberglass reinforcement encapsulated between two plies of PVC. The membrane is available in white, gray and custom colors. Available thicknesses range from 50 mils [0.050 inch (1.27 mm) to 80 mils [0.080 inch (2.03 mm)]. 3.3.3 Sure -Flex FleeceBACK: Sure -Flex FleeceBACK is the Sure -Flex membrane, described in Sections 3.3.1 and 3.3.2, with a laminated 5.5 -ounce -per -square -yard (0.18 kg/m2) polyester fleece backing. Available thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 135 mils [0.135 inch (3.43 mm)]. 3.4 TPO Membranes: 3.4.1 Sure -Weld: Sure -Weld membrane consists of a polyester reinforcement encapsulated between two plies of TPO. The membrane is available,in white, gray, tan and custom colors. Available thicknesses range from 45 mils [0.045 inch (1.14 mm)] to 80 mils [0.080 inch (2.03 mm)]. 3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld membrane formulated with an additional flame retardant for fire resistance at higher slopes. The membrane is available in white, gray, tan and custom colors. Available thicknesses are 45 mils (0.045 inch [1.14 mm]) and 60 mils (0.060 inch [1.52 mm]). 3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of the Sure -Weld HS membrane with adhesive. 3.4.4 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK is the Sure -Weld HS membrane, 45 mils [0.045 inch (1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils [0.60 inch (2.03 mm)] thick, with a laminated 5.5 -ounce - per -square -yard (0.18 kg /M2) polyester fleece backing. Available thicknesses are 100 mils [0.1d0 inch (2.54 mm)], 115 mils [0.115 inch (2.92 mm)] and 135 mils [0.135 inch (3.43 mm)]. 3.4.5 Sure -Weld AFX: Sure -Weld AFX is the Sure -Weld HS membrane with a laminated 10 -ounce -per -square - yard (0.34 kg/m2) polyester fleece backing. Available thicknesses range from 120 mils [0.120 inch (3.05 mm)] to 155 mils [0.155 inch (3.94 mm)]. 3.4.6 Spectro-Weld: Spectro-Weld is the Sure -Weld membrane, described in Section 3.4.1, formulated with a 3.4.7 Spectro-Weld FleeceBACK: Spectro-Weld FleeceBACK is the Spectro-Weld membrane with a laminated 5.5 -ounce -per -square -yard (0.18 kg/m2) polyester fleece backing. It is 115 mils [0.115 inch (2.92 mm)] thick. 3.5 Insulation: See Tables 2 through 4 for insulations for use with specific roofing systems. Foam plastic insulation, where used, must have a flame -spread index of not more than 75 when tested at the maximum`thickness intended for use in accordance with ASTM E84. 3.6 Barrier Board: Barrier board, where used, must be either minimum 1/4-irich-thick (6.4 - mm� G -P Gypsum Corporation "DensDeck," minimum /4 -inch -thick (6.4 mm) Owens Corning "Strataguard", -minimum 1/4 -inch -thick (6.4 mm) USG "Securock," or minimum 1/2 -inch -thick (12.7 mm) gypsum board. Barrier board must be UL -listed for roofing applications or UL -classified gypsum board. 3.7 Slip Sheet: The slip sheet, where used, must include Carlisle "FR Base Sheet 1S or 2S," Elk "VersaShield Underlayment," Elk "VersaShield F8 -1S or FB -2S, or Atlas FR 10 or FR 50." 3.8 Flashing: Flashing must be provided in accordance with IBC Section 1503.2 or -IRC Section R903.2, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.9 Fasteners: Fasteners, used to mechanically attach insulation -and membranes to the roof deck, must be corrosion -resistant, and must be Carlisle fasteners, plates or fastening bars, unless otherwise noted in this report. Refer to Table 4 for spacing of fasteners. 3.9.1 HP Fastener: This is an epoxy -coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck'a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.2 InsulFast Insulation Fastener: This is an epoxy - coated steel screw used in combination with Carlisle's insulation plates to mechanically attach roofing insulation to steel or wood substrates. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), or into the wood deck a minimum of 1 inch (25.4 mm). 3.9.3 HP Purlin Fastener:. This is an epoxy -coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to structural steel members. Fastener length must be selected to penetrate through the steel member a minimum of 3/4 inch (19.1 mm.) 3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy - coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to concrete roof deck. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). designed to be used with insulation and seam fastening plates to secure membrane and insulation to structural concrete. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.6 Lite -Deck Fastener: The Lite -Deck Fastener, is used in conjunction with a specially designed 3 -inch (76.2 mm) Lite -Deck Metal Plate for. insulation attachment to gypsum, cementitious wood fiber (Tectum [ESR -1112j), and lightweight concrete decks. Fastener length must be selected to penetrate into the deck a minimum of 2 inches (50.8 mm). ' 3.9.7 GypTec Fastener: The GypTec Fastener is a glass -filled nylon auger fastener designed for securing mechanically attached membranes and insulation to gypsum and cementitious wood fiber (Tectum [ESR -1112]) decks. Fastener length must be selected to penetrate into the deck a minimum of 1.5 inches (38.1 mm). 3.9.8 HP Polymer Seam Plate: This is a 2 -inch -diameter (50 mm) polymer plate designed to be used with HP and HD 14-10 fasteners to mechanically attach roofing membranes to the roof deck. 3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is a heavy-duty, epoxy -coated steel screw and bar used to secure reinforced EPDM membranes to steel or wood deck. The bar is 1 -inch -wide -by -0.040 -inch -thick -by - 10 -foot -long (25.4 mm by 1.1 mm by 3.1 m) galvalume- coated steel with prepunched holes 6 inches (150 mm) on center. 3.9.10 HP -X Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha Fastening Plate to mechanically attach TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.11 Piranha Fastening Plate: This is a 23/8 -inch - diameter galvalume-coated steel plate designed to be used with HP -X fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.12 HP-XTRA Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha XTRA Fastening Plate to mechanically attach PVC and TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm) and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.13 Piranha XTRA Fastening Plate: This is a 23/8 -inch -diameter galvalume-coated steel plate designed to be used with HP-XTRA fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.14 PVC Oval Barbed Plate: This is a 11/2 -inch -by - 23/4 -inch (35 mm by 69.85 mm) Oval Barbed Plate designed to be used with HP -X Fasteners to mechanically attach PVC membranes to the roof deck. 3.9.15 OMG Inc. RhinoBond Plate: The RhinoBond Plate is a 3 -inch -diameter (76.2 mm), 0.028 -inch -thick (0.7 mm) galvalume-coated steel plate, coated with a proprietary adhesive and used with the HP -X fastener to mechanically attach PVC and TPO membranes to the roof deck. The adhesive bonds the plate to the underside of the membrane. 3.10 Adhesives: 3.10.1 90-830A Bonding Adhesive: 90-8-30A Bonding insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 M2 /Q. The adhesive is supplied in 5 -gallon (18.9 L) containers and has a shelf life of one year. 3.10.2 Aqua Base 120: Aqua Base 120 is a high-strength, water-based contact adhesive used to adhere EPDM, TPO and PVC membranes to the insulation or substrate. It has a coverage rate of approximately 120 square feet per gallon (3 m2/L). The adhesive is supplied in 5 -gallon (18.9 L) containers and has a shelf life of one year. 3.10.3 Sure -Flex low-VOC PVC Bonding Adhesives: Sure -Flex Low VOC PVC Bonding Adhesives is high- strength, solvent -based contact adhesives used to adhere PVC membranes to an insulation or substrate. They have a coverage rate of approximately 60 square feet per gallon (1.5 m2/L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld Bonding Adhesive is a high-strength, solvent -based contact adhesive used to adhere TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2 /L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding Adhesive is a high-strength, solvent -based contact adhesive used to adhere EPDM and TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2/ Q. The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.6 HydroBond PVC Water -Based Adhesive: HydroBond PVC Water -Based Adhesive is a water-based, wet lay -in, one-sided adhesive to be used to adhere Sure - Flex PVC and PVC FleeceBACK membranes to an insulation or substrate. It has a coverage rate of 100 square feet per gallon (2.5 m2/L). The adhesive is supplied in 5 -gallon 918.9 L) containers with a shelf life of one year. 3.10.7 Low VOC Bonding Adhesive 1168: Low VOC Bonding Adhesive 1168 is high-strength, solvent -based contact adhesive used to adhere EPDM and TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.58 m2/L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.8 Solvent -Free EPDM Bonding Adhesive: Solvent - Free EPDM Bonding Adhesive is a high-strength, polymer - based adhesive. This adhesive can be used to adhere all Sure -Seal or Sure -White EPDM membranes as a one- sided, wet lay -in adhesive. It has a coverage rate of 100 square feet per gallon (2.5 m2 /L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of six months. 3.10.9 Cold Applied Adhesive: Cold Applied Adhesive is a solvent -free, asphalt -modified polyether adhesive. This adhesive can be used with all Sure -Seal or Sure -Weld AFX membranes as a one-sided, wet lay -in adhesive. It has a coverage rate of 67 square feet per gallon (1.6 m2 /Q. The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.10 FAST Adhesives: FAST 100, FAST 100LV, FAST Adhesive Dual Cartridge, FAST Adhesive Box Sets, Flexible FAST and FAST Bag -in -a -Box Adhesives are two - substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 m2 /L). The adhesives are supplied in 15 -gallon (56.7 L) and 50 -gallon (189 L) drums, box sets, and cartridge tubes and cylinders, and have a shelf life of one year. 3.10.11 OlyBond 500 Adhesive: OlyBond 500 Spot Shot and OlyBond 500 BA are two -component polyurethane adhesives used to adhere . insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 m2/L). The adhesives are supplied in cartridge tubes and box sets, and have a shelf life of one year. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in IBC Section 1504.7, based on testing in accordance with FM 4470. 4.0 INSTALLATION 4.1 General: Installation of the EPDM, PVC, and TPO roofing membranes described in this report must comply with the applicable code, the manufacturer's published installation instructions and this report. The manufacturer's published installation Jnstructions must be available at all times on the jobsite during installation. The substrate to which the membrane is to be applied must be clean, dry, and free of frost, loose fasteners, and other protrusions or contaminates that will interfere with the adhesion or attachment of the membrane or that will puncture the membrane. All materials must be protected against contact with incompatible materials. Where gypsum board is used as barrier board in the roofing assembly, weather protection must be provided to prevent damage to the gypsum board prior to application of the roofing membrane. The slope of the roof on which the single -ply membranes are installed must not be more than the maximum slope indicated for the particular assembly as listed in Tables 2 and 3. Penetrations and terminations of the roof covering must be flashed and made weather tight in accordance with the requirements of the membrane manufacturer and the applicable code. 4.2 Fire Classification: 4.2.1 New Construction: The adhered and mechanically fastened EPDM, -PVC, and TPO single -ply membrane roofing systems, when installed in accordance with this report, are Class A, B or C roof covering systems in accordance with ASTM E108 or UL 790, as noted in Tables 2 and 3. 4.2.2 Reroofing: The existing deck must be inspected to verify that the structure to be reroofed is structurally sound and adequate to support and secure the roofing membrane. Prior to installation of new roof coverings, inspection by and written approval from the code official having jurisdiction must be required. Class A, B or C roof covering systems may be installed over existing classified roof covering systems under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new or existing roofing classification: ■ NPw uninsiilatad systams installed only nver axistinn ■ New insulated . systems installed over existing uninsulated systems only. 4.3 Wind Resistance: 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. Metal edge securement for roofing systems must be designed in accordance with ANSI/SPRI ES -1, complying with IBC Section 1504.5. The edge securement for mechanically attached membranes was tested in accordance with ANSI/SPRI ES -1 Test RE -1, using Carlisle SecurEdge 300 [0.050 -inch (1.27 mm) 3003 aluminum] and Carlisle- SecurEdge 3000 [0.040 -inch (1.02 mm) 3003 aluminum] fascia systems. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m). 4.3.2 Reroofing: Mechanically anchored systems may be accepted based on the adequacy of anchors penetrating through existing roof coverings into structural substrates. Since the composition and/or condition of any particular existing underlying material may vary widely, reroofing with adhered systems is outside the scope of this report. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer's published installation instructions and this report. The instructions within this report must govern if there are any conflicts between the manufacturer's installation instructions and this report. 5.2 The adhered and mechanically fastened single -ply membrane roofing systems must be installed by professional roofing contractors who are trained and approved by the manufacturer. 5.3 Foam plastic insulation must be separated from' the interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5 or IRC Section R314.4, as applicable. 5.4 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam plastic has a flame -spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E84, subject to the approval of the code official. 5.5 Design wind uplift pressure on any roof area, including edge and corner zones, must not exceed the allowable wind uplift pressure for the system installed in that particular area. Refer to allowable wind uplift pressures for systems as listed in Table 4. 5.6 The allowable wind uplift pressures listed in Table 4 are for the roof covering' system only. The deck and framing to which the system is attached must be designed for the applicable components and cladding wind loads in accordance with the applicable code. 5.7 When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the nnrla nffininl fnr annrnval at tha times of narmit 5.8 The roofing membranes are manufactured at Carlisle, Pennsylvania; Greenville, Illinois; Tooele, Utah; and Senatobia, Mississippi, • under a quality control program with inspections by UL LLC (AA -668). 5.9 For buildings under the IBC, aboveAeck thermal insulation board must comply with the applicable standards listed in Table 1508.2 of the IBC. 6.0 EVIDENCE SUBMITTED Data in accordance with ICC -ES Acceptance Criteria for Membrane Roof Covering Systems (AC75), dated July 2010. 7.0 IDENTIFICATION Each roll of the roofing membrane must bear a label noting the product name, the manufacturer's name (Carlisle SynTec) _or the name of the additional listee, the manufacturer's address or plant code, the ICC -ES evaluation report number (ESR -1463), and the name or label of the inspection agency (UL LLC). 8.0 OTHER CODES In addition to the codes referenced in Section 1.0, the products in this report were evaluated for compliance with the requirements of the following codes: ■ BOCe National Building Code/1999 (BNBC) ■ 1999 Standard Building Code® (SBC) ■ 1997 Uniform Building CodeTm (UBC) For compliance under the above codes, see Sections 2 through 7 of this report, except revise the following sections to read as follows: 0.0oll 1. 3.8 Flashing: Flashing must be provided in accordance with SBC Section 1503.2, BNBC Section 1508.1 and UBC Section 1509, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No. 26 gage [0.019 inch (0.483 mm)) galvanized steel. 3.11 Impact Resistance: The EPDM, , PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in BNBC Section 1505.4.2, and SBC Section 1504.6, based on testing in accordance with FM 4470. 4.3.1 New Construction: The allowable wind uplift pressures 'for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 8.0 of this report, subject to the following conditions: f See Sections 5.1 through 5.8, except revise Section 5.3 to read as follows: 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with BNBC Section 2603.4.1.5, SBC Section 2603.5.1.5, and UBC Sections 2602.4 and 2602.5.3, as applicable. 3K±:Ci'�eil T-014 .fidC;:` i:`a..DiliSi:.4+Y:'E i;1J�':I. I~'� saiY*dS�� �''�altL`S'I,9I'i 4i� � .:112'b^CS43 a a.711•C<.;.S:.P}° to t rfe�,xal,�a-,axz �cai'i?i:��asaaa<• *��."�f.�"el:S f Cy E :i'4ti:ttkP4 of PAq4to Ctrzifitki fin.�{,�wN+d:_, ;: L..�f;: }its-��kic�. «A•Jz���is ai�xfl Sy��a:�zw �5i�crs_iat FIGURE 1—INSPECTION AGENCY LABEL TABLE 1—PRODUCT NAMES CARLISLE PRODUCT MULE -HIDE PRODUCT WEATHERBOND PRODUCT VERSICO PRODUCT NAME KELLY CO./ NAME NAME NAME ' 2001 INC., r PRODUCTNAME Sure -Seal Mule -Hide Standard EPDM WeatherBond RBR EPDM Non- Versigard Non -reinforced PREMIUM', C=EPDM-C reinforced Membrane EPDM Membrane STANDARD. Sure -Seal FR Mule -Hide FR EPDM -WeatherBond RBR FR EPDM VefsiGard FR Nonreinforced C-EPDM-C Non -reinforced Membrane EPDM Sure -Seal Fleece BACK VersiFleece EPDM Membrane PREMIUM Sure -Seal AFX VersiFleece AC EPDM Membrane ' Sure -Tough Reinforced Mule -Hide Standard WeatherBond RBR Standard Versigard Reinforced PREMIUM, C-EPDM=C, Reinforced EPDM Reinforced EPDM Membrane EPDM Membrane STANDARD, C-EPDM-CR Sure -Tough FR Mule-Hide FR Reinforced WeatherBond RBR FR VersigardFR Reinforced C-EPDM-CR Type 1 Reinforced EPDM Reinforced EPDM Membrane 1r 1'' Sure -White Mule -Hide White -on -Black WeatherBond RBR White EPDM Versigard Nonreinforced EPDM PREMIUM, EPDM RF - EPDM Membrane -White White Sure -White Fleece BACK Sure -Weld Mule -Hide TPO-c WeatherBond PRO TPO Versiweld Reinforced TPO ' Reinforced TPO /White Membrane Membrane TPO­ Sure-Weld Sure -Weld HS Mule -Hide TPO-c (FR) Versiweld ES SAT-TPO Mule -Hide SA-TPO WeatherBond PRO PAS TPO Versiweld OA TPO Sure -Weld Fleece BACK Mule -Hide TPO-c Fleece VersiFleece TPO Membrane Back 'Sure -Weld AFX Mule -Hide TPO-C Fleece VersiFleece AC TPO Back Plus Membrane Spectro-Weld 7` Spectro-Weld FleeceBack Sure -Flex Mule -Hide PVC Membrane WeatherBond PRO PVC VersiFlex Reinforced PVC Membrane Sure -Flex KEE VersiFlex-E PVC Membrane Sure -Flex FRS Mule -Hide FRS PVC VersiFlex FRS Reinforced PVC Membrane Membrane Sure -Flex FleeceBack VersiFleece PVC Membrane 90-8-30A Bonding Mule -Hide Bonding Adhesive WeatherBond RBR LC -60 G200SA Yellow Substrate 2001 Inc. Bonding Adhesive Adhesive Bonding Adhesive Adhesive Solvent -Free EPDM Solvent -Free EPDM Bonding Solvent -Free EPDM Bonding Bonding Adhesive Adhesive Adhesive Aqua Base 120 Bonding Mule -Hide WBBA-2000 Aqua Base 120 Bonding Aqua Base 120 Bonding Adhesive Bonding Adhesive Adhesive Adhesive Sure -Weld Bonding Mule -Hide TPO-c Bonding WeatherBond PRO TPO Versiweld Bonding Adhesive Adhesive Adhesive Bonding Adhesive Low VOC Bonding Mule -Hide Low VOC Bonding LOW VOC Bonding Adhesive LOW VOC Bonding Adhesive Adhesive Adhesive Low VOC Bonding Low VOC Bonding Adhesive Low VOC Bonding Adhesive Adhesive 1168 1168 1168 Sure -Flex Low VOC Mule -Hide Low VOC PVC WeatherBond Low VOC PVC VersiFlex Low VOC PVC PVC Bonding Adhesive Bonding Adhesive Bonding Adhesive Bonding Adhesive Hydro Bond PVC Water- Hydro Bond PVC Water -Based HydroBond PVC Water -Based Based Adhesive Adhesive Adhesive Cold Applied Adhesive Cold Applied Adhesive FAST 100 Adhesive Mule -Hide SP -100 Adhesive FAST 100 Adhesive FAST 100 LV Adhesive Mule -Hide SP -100 -LT FAST 100 LV Adhesive Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS25 SYSTEM .ROOF DECK BARRIER BOARD INSULATION' MEMBRANEIMAX. ROOF SLOPE NO. CLASS OR SLIP SHEET Sure -Weld, Spectro-Weld -'/4:12 Any of the following insulations, Sure -Seal, Sure -Tough, Sure -White, Sure - 1 -inch min. to 6 -inch max. thickness: Carlisle "SecurShield Seal FleeceBACK, Sure -Weld HS, SAT-TPO, 1 A Noncombustible Polyiso", "Polyiso HP -H", Hunter "H Sure -Weld FleeceBACK�Spectro-Weld FleeceBACK - /2:12 Panels -Shield" or "H -Shield -CG" Sure -White FleeceBACK Sure -Flex, Sure - Flex FRS - /4:12 1/2 -inch -thick fiberboard 4,'/2 -inch- Sure -White FleeceBACK-'/4:12 /4: thick fiberboard or barrier board (see Section 3.6) 03e� 5 -inch Sure -Seal, Sure -Tough - 2 2 A Noncombustible — EPS /2 inch- max Iberboa Sure -White, Sure -Seal FleeceBACK, Sure - , thick fiberboard or barrier board d Weld, Spectro-Weld, Sure -Weld HS, SAT - (see Section over System TPO, Sure --Weld FleeceBACK, Spectro-Weld No. 1 insulations nsu FleeceBACK, Sure -Flex, Sure -Flex FRS - 1,/2:12 Sure -White FleeceBACK-3/4:12 Sure -White, Sure -Seal FleeceBACK - 11/2:12 Noncombustible or Combustible -min. Sure -Tough, Sure -Weld, Spectro-Weld, Sure - 3 A 15/32-inch4hick Barrier board — Weld FleeceBACK, Spectro-Weld plywood or min. (see Section 3.6) FleeceBACK - 3:12 '/18 -inch -thick OSB. Sure -Weld HS, SAT-TPO - 4:12 Sure -Seal FR, Sure -Flex, Sure -Flex FRS – unlimited slope Any of the following insulations, Sure -Weld, Spectro-Weld -'/4:12 Combustible - min. Barrier board 1 -inch min. Sure -Seal, Sure -Tough, Sure -White, Sure - 15 /32 inch -thick (see Section 3.6) or to 6 -inch max. thickness: "SecurShield Seal FleeceBACK, Sure -Weld HS, SAT-TPO, 4 A 7/ plywood or min. Slip sheet: 2 layers Carlisle Polyiso", Polyiso HP -H", Sure -Weld FleeceBACK, Spectro-Weld FleeceBACK -'/2:12 ,e -inch -thick OSB. (see Section 3.7) Hunter Panels "H -Shield" or Sure -White FleeceBACK, Sure -Flex, Sure - "H -Shield -CG" Flex FRS -3/4:12 Combustible - min. 1513rinch4hick Any of the following insulations, Sure -Weld, Spectro-Weld, Sure -Weld HS, 5 C _ 2 -inch min. to 6 -inch max. SAT-TPO, Sure -Flex, Sure -Flex FRS – plywood or min. 7/ plywood thickness: Carlisle "Polyiso HP- "H unlimited slope OSB. H" or Hunter Panels -Shield" Single layer of minimum 3.0" or double layer of minimum 1.5" 6 A Combustible — Carlisle "SecurShield Polyiso" or EPDM, PVC, and TPO Membranes -1/2:12 Hunter Panels "H -Shield -CG" Single layer of minimum 1.9" 7 B Combustible — Carlisle "SecurShield Polyiso" or EPDM, PVC, and TPO Membranes -'/2:12 Hunter Panels "H -Shield -CG" For SI: 1 inch = 25.4 mm. 1 All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2See Section 3.10 for adhesive application rate. 3 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope 1:12) or below min. 1/2 -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. '/2:12. 5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. TABLE 3—FIRE CLASSIFICATION ASSEMBLIES -MECHANICALLY FASTENED ROOFING SYSTEMS° SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANE/MAX: ROOF NO, CLASS OR SLIP SHEET ' SLOPE Any of the following insulations, 1 -inch min. to Sure -Tough, Sure -Weld, 1 A6 Noncombustible -inch max. thickness: Carlisle "SecurShield "Polyiso Spectro-Weld, Sure -Flex, Sure - Flex FRS - /2:12 Polyiso" or HP -H", Hunter Panels "H- "H , Sure -Weld HS - 11/212 Shield" or -Shield -CG" Sure -Tough FR - 2:12 1/2 -inch -thick fiberboard 3,'/2 -inch -thick Sure -Tough, Sure -Weld HS, fiberboard or barrier board (see Section -3.6) Sure -Flex, Sure -Flex FRS - 1:12 2 A Noncombustible — over 5 -inch max Insulfoam EPS2,'/.-inch-thick Sure -Weld, Spectro-Weld - fiberboard or barrier board (see Section 3.6) 1'/2:12 over System No. 1 insulations Sure -Tough FR - 3'/2:12 Sure -Weld, Spectro-Weld, Sure - 3 A Noncombustible — To 5 -inch max: Insulfoam SP Weld HS, Sure -Flex, Sure -Flex FRS -'/2:12 Noncombustible or Sure -Tough, Sure -Weld, Combustible - min. 15/32 Barrier board Spectro-Weld - 3:12 4 A -inch -thick (see Section 3.6) _ Sure -Tough FR - 31/2:12 plywood or min. Sure -Weld HS, Sure -Flex, Sure - 7/16 -inch -thick OSB. Flex FRS - unlimited Combustible - min. Barrier board Any of the following insulations, 1 -inch min. Sure -Tough, Sure -Weld, ,s/g2-inch-thick (see Section 3.6) to 6 -inch max. thickness: Carlisle Spectro-Weld, Sure -Flex, Sure - , 5 A plywood or min. or Slip sheet: 2 "SecurShield Polyiso" or "Polyiso HP -H",' Flex FRS - 12:12 7/1 s -inch -thick OSB. layers, (see Section Hunter Panels Sure -Weld HS, 1'/2:12 3.7) "H -Shield" or "H -Shield -CG" Sure=Tough FR - 2:12 Combustible -min. Sure -Tough - 1:12 ,s /32 -inch -thick Slip sheet, 2 layers Sure -Tough. FR, Sure Weld, 6 A plywood..or min. (see Section 3.7) — Spectro-Weld, Sure -Weld HS, /,e -inch -thick OSB. Sure -Flex, Sure -Flex FRS - 02:12 Combustible - min. Sure -Tough, Sure -Tough FR, 7 B 15/3. -inch -thick . Slip sheet, 1 layer — Sure -Weld, Spectro-Weld, plywood or min. (see Section 3.7) Sure -Weld HS, Sure -Flex, Sure - '/,6 -inch -thick OSB. Flex FRS - 11/2:12 Combustible -min. Any of the following insulations, 2 -inch min'. j ,s/32 -inch -thick to 6 -inch max. thickness: Carlisle "Polyiso Sure -Weld, Spectro-Weld, 8 C — "SecurShield Polyiso" or Sure -Weld HS, Sure -Flex, Sure - plywood or min. /,e -inch -thick OSB. HP -H", Hunter Panels "H -Shield" or H -Shield. Flex FRS - unlimited CG" Single layer of minimum 3 -inch or double layer 9 A Combustible — of minimum 1.5 -inch Carlisle "SecurShield Polyiso" or EPDM, PVC, and TPO Membranes -'/2:12 Hunter Panels "H -Shield -CG" Single layer of minimum 1..9 -inch Carlisle 10 B Combustible "SecurShield Polyiso" or Hunter Panels "H- EPDM, PVC, and TPO _ Shield -CG" or single layer of an inverted G3 Membranes - /2:12 cap sheet.' For SI: 1 inch= 25.4 mm. 'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 3Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as'a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to' /2:12. "When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. TABLE 4—WIND RESISTANCE—MECHANICALLY FASTENED'ASSEMBLIES°'' SYSTEM MAXIMUM DECKS INSULATION 5 MEMBRANE MEMBRANE MAXIMUM MAXIMUM NO. ALLOWABLE FASTENING FASTENER FASTENER WIND UPLIFT SPACING ROW (psf) (inches) SPACINGs Foam plastic insulation'''4 '/z-inch4hick fiberboards or H P -X Fastener & 1 45 Noncombustible barrier board Sure -Tough Metal Fastening Bar 12 6 ft 6 inches (See Sect. 3.6) 2 •75 Noncombustible Same as System No. 1 Sure -Tough Hal Fastener & 6 6 ft 6 inches Mettal Fastening Bar 3 52 Noncombustible Same as System No. 1 Sure -Tough Fastener &mer 6 9 It 6 inches Poy PolySeam Plate 4 45 Noncombustible Same as System No. 1 Sure -Tough Sure-Tite Fastener & 12 9 It 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 12 9 It 6 inches (75 mil) Polymer Seam Plate - 6 -60 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 6 9 ft 6 inches (75 mil) Polymer Seam Plate Sure -Weld or HP -X or HP -Xtra 7 45 Noncombustible Same as System No. 1 Spedro-Weld Fasteners with Piranha 12 7 ft 6 inches or Piranha Xtra Plates 8 45 Noncombustible Same as System No. 1 Sure -Weld or HP -Xtra Fasteners with 12 9 It 6 inches Spedro-Weld Piranha Xtra Plates H P -X or H P -Xtra 9 60 Noncombustible Same as System No. 1 Sure -Weld or Fasteners with 6 9 ft 6 inches Spedro-Weld Piranha or Piranha Xtra Plates Sure -Weld or HP -X or HP -Xtra 10 67 Noncombustible Same as System No. 1 Spedro-Weld Fasteners with Piranha 6 7 It 6 inches or Piranha Xtra Plates Sure -Weld or HP -X or HP -Xtra 11 30 Noncombustible Same as System No. 1 Spedro-Weld Fasteners with Piranha 12 11 ft 6 inches or Piranha Xtra Plates Sure -Weld or HP -X or HP -Xtra 12 60 Noncombustible Same as System No. 1 Spedro-Weld Fasteners with Piranha 6 11 ft 6 inches or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure -Flet HP -X Fasteners with 6 6 ft 4 inches Piranha Plates 14 83 Noncombustible Same as System No. 1 Sure -Flex HPFasteners with 6 2 ft 11 inches P Piranha Plates H P -X or H P -Xtra 15 30 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 18 6 ft 4 inches or Piranha Xtra Plates HP -X or HP -Xtra 16 45 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with 12 2 ft 11 inches Piranha Plates 18 45 Noncombustible Same as System No. 1 Sure -Weld HP -X Fasteners with 1 per 5.3 ft N/A OMG RhinoBond Plates 19 60 Noncombustible Same as System No. IT Sure -Weld HP -X Fasteners with 1 per 4 ft2 N/A OMG RhinoBond Plates For SI: 1 inch = 25.4 mm; 1 It = 0.305 m; 1 psf = 47.88 Pa. 'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShield Polyiso" "Polyiso HP -H" Hunter Panels "H -Shield" or Hunter Panels "H -Shield- CG". 2AII foam plastic insulation must be UL -classed foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 3Steel deck must be minimum No. 22 gage galvanized steel (base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (Q of 2500 psi. See Section 5.6 of this report. °For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2. 5UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min. 1/7 -inch - thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 6Carlisle SecurShield HD or Hunter Panels HShield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to 1/212. 7 When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. 8 Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly. TABLE 5—{MND RESISTANCE—ADHERED'ASSEMBLIESS SYSTEM ALLOWABLE DECK2 INSULATION / MIN. THICKNESS''' INSULATION MEMBRANE NO. WIND UPLIFT FASTENING TYPE (FIELD) (psf) RATE 1 45 Combustible or 1/2 inch fiberboard 4,15/32inch OSB, or barrier board 1 per 2112 p EPDM, PVC and TPO Noncombustible (See Section 3.6) Membranes Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; EPDM, PVC and TPO 2 45 Noncombustible Hunter Panels "H -Shield" or "H -Shield -CG" / 1.4 inch ; 1 per. 3.2 It Membranes with'/2-inch Securock coverboard (optional) 3 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter "H or "H 2.0 inch EPDM, PVC and TPO 45 Noncombustible Panels -Shield" -Shield -CG" / with 5/e -inch Securock coverboard (optional) 1 per 4 ftz Membranes 4 68 Combustible or Carlisle "Polyiso HP -W or "SecurShield Polyiso"; FAST Adhesive FleeceBACK Membranes Noncombustible Hunter Panels "H -Shield" or "H -Shield -CG" / 1.0 inch Combustible or Carlisle "Polyiso HP -H" or"SecurShield Polyiso'; "H "H z EPDM, PVC and TPO 5 75 Noncombustible Hunter Panels -Shield" or -Shield -CG" / 2.0 inch 1 per 1.6 ft Membranes with'/Tinch Securock coverboard (optional) TPO Membranes; 6 120 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; "H "H 1er.1 ft p EPDM membranes (with Noncombustible Hunter'Panels -Shield" or -Shield -CG" / 2.0 inch noncombustible deck only) 7 128 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter Panels "H "H / 2.0 inch z 1 1 ft EPDM and TPO Noncombustible -Shield" or -Shield -CG" per Membranes f with '/z -inch Securock coverboard (optional) Combustible or 'Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; 8 135 Noncombustible Hunter Panels "H -Shield" or "H -Shield -CG" / 2.0 inch 1 per 1 ftz FleeceBACK Membranes + . with 1/2 -inch Securock coverboard (optional) 9 143 Combustible or 1/2 inch DensDeck Prime 1 per 1-ft2 FleeceBACK Membranes Noncombustible For SI: 1 inch = 25.4 mm; 1 It = 0.305 m; 1 psf = 47.88 Pa 'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this reportor the maximum thickness in accordance with this table, whichever -is less. zSteel deck must be minimum No. 22 gage galvanized steel (base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (F.) of 2500 psi. See Section 5.6 of this report. 'UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope 1:12) or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. °Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to'/2:12. SWhen application is over existing roofs, documentation of the wind -uplift resistance of the'composite roof construction must be submitted to the code official for approval at the time of permit application. For reroofing or recovering, installation must be in accordance with IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to.Chapter 15, as applicable.