13-1463 (RR)•
I
P.O. BOX 1504 4^' VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 11/18/13
Application Number: 13-00001463 Owner:
Property Address: 49040 CALLE FLORA JESSER KENNETH
APN: 658-210-033- - - 49040 CALLE FLORA
Application description: RE -ROOF LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL (
Application valuation: 20727
Contractor:
Applicant: Architect or Engineer: WINKLE COMPANY, R.D.
P.O. BOX 476
THOUSAND PALMS, CA 92
(76.)322:5144 Nov I8
Lic. No.: 688062 i�
Yy
CIFiNANe DEPT A
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
LicenseClass: C39 C46 L'cense o.: 688062
Date/—�'3 Contractor: .
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
�I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0000182-2013
1 certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with t se provisions.
Dateff/� Applicant:
WARNING: FAILURE TO WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for.a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes
7
W)
Date: 11ySignature (Applicant or Agent):
Application Number . . . 13-00001463
Permit . . . RE -ROOF
Additional desc .
Permit Fee . . . . 71.50 Plan Check
Fee
.00
Issue Date Valuation
. . .
. 0
Expiration Date 5/17/14
Qty Unit Charge Per
Extension
1.00 48.6200 LS MISC RE -ROOF, 1ST 2000
SF
48.62
2.00 11.4400 EA . MISC RE -ROOF, ADDL 1000 SF
22.88
----------------------------------'----_---------------------------------------
Special Notes and Comments
REROOF WITH INSULATION THERMOPLASTIC
POLYOLEFIN - [CRRC: 0628-00021 2010
CALIFORNIA ENERGY CODE.
------------- --------------------------------------------------------------
Other Fees . . . . . . . . . PLAN CHECK, RE -ROOF
97.24
Fee summary Charged Paid Credited
----------------- ---------- ---------- --------------------
Due
Permit Fee Total 71.50 .00
.00
71.50
Plan Check Total .00 .�00
.00
.00
Other Fee Total 97.24 .00
.00
97.24
Grand Total 168.74 .Ob
.00
168.74
LQPERMIT
Bin.#
city 0f 1+Q Q[llntd
Building & Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La.Quinta, CA 92253 -:(760) 777-7012
Building Permit Application and Tracking Sheet
Perinit #
Project Address: 49040 Calle Flora
Owner's Name:. Jesser Residence
A. P. Number.
Address: 49040 Calle Flora
Legal Description:
City, ST, Zip. La Quinta CA. 92253
Contractor: R D Winkle co
Telephone:
ep
Address: PO Box 476
Project Description:
City, ST, Zip: Thousand Palms, CA. 92253
Re-Roof with 1ar� 60mil TPO
Telephone: 760-322-5144
:•
Existing Root Will be Recovered.with EPS
State Lie. #:688062 City Lie.
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone:
"f
State Lia #:zw" �:::..:ax ..: i:�,«
Construction TYpe:Roofing Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: Ryan A. Winkle
Sq. Ft.: 4,500
# Stories: 1
# Units:
Telephone # of Contact Person:
Estimated Value of Project: 20,727.00
APPLICANT: DO NOT WRITE BELOW THIS UNE
# Submittal Req'd Recd TRACKING PERMIT FEES
Plan Sets
Plan Cheek submitted
Item Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit, .
Truss Cates.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Pians picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
V Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN ROUSE:
'^' Review; ready for correctionstiissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr '
Date of permit issue
School Fees
Total Permit Fees
'W"W INKLOO
ROOF 'CONSTRUCTOR S
Tuesday, October 1, 2013
The Jesser Residence
49040 Calle Flora
La Quinta, CA. 92253
Attn: Ms. Jamie Jesser
Re: Re -Roof Low -Slope Roofing System
This proposal is in regard to the above referenced project. We are proposing the new low -
slope roofing system. We have provided two re -roofing options. Furnishings and installations
will be as explained below;
Thermoplastic Polyolefin (TPO) Roofing System
Demolition & Clean Up: RDW will remove the existing gravel from low -slope roofing system.
All exposed fasteners from the existing roofing system will be pulled from the substrate, this
will give a cleaner surface for the preparations of the new roofing system and,will in sure that the
old fasteners will not puncture the new material. All roofing debris on the ground will be swept
up and the grounds will be rolled with a magnet to pick up any fasteners or metal scraps that had
fallen during the demolition. RDW will dispose of all roofing waste.
Board Insulation: RDW will supply and installed a single layer of I" rigid EPS board
insulation. The board insulation will overlay the existing built-up roof. By overlaying the
existing built-up roof the waste will be minimized and the new roofing system will maintain a
class "A "fire rating. The EPS will provide a smooth surface for the new roofing system and will
give additional insulation of approximately R-6 aged value. RDW will mechanically fasten the
insulation to the substrate using 3" plates and 2" fasteners. The fasteners will be installed in an
I-90 pattern giving a 90mph wind rating. Additional insulation will be added to standing water
areas. This will help reduce standing water, not eliminate it.
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062
SIN cam'
R 00 f C 0 N S7 P U CT OR S
Thermoplastic Polyolefin (TPO): This is a single ply mechanically attached roofing system.
We will be installing a 60mil-reinforced membrane that will be 8' or 10' by 100' roll. This
allows us to have less field seams and end lap seams than your typical built-up roofs. This is a
sure weld membrane meaning that all seams are heat welded together, compared to either hot
tar in a built up roof or an open flame used in torch on roofs. The field will be seamed with a
robotic heat welder giving a continuous and consistent weld Details, such as flashings and
corners will be welded by hand. Welds will then be checked with a probe. The product is much
safer, cleaner, and does not produce any unpleasant odor when being installed Other positives
to this roofing system are that the TPO membrane is highly reflective and helps reduce energy
consumption cost, it will provide a long term resistance to the punishing ultraviolet rays we
receive here in the western states. This system meets California Title 24 specifications. The
TPO roofing system will be installed to the manufactures specifications. This roofing system
meets the specifications for a Manufacture 20 year No Dollar Limit (NDL) Warranty.
Flashings and Corner Details: All vent pipe flashings will receive a pre -manufactured TPO
boot flashing, the collars will be sealed with cut off mastic and hose clamps. All inside and
outside corner details will receive pre -manufactured non -reinforced TPO corners. All flashings
and corners will be hand welded and check with probes.
Polyurethane Foam: The surface will be primed at the rate of .33 - .50 gallons per 100 square
feet with a Neoprime primer. Polyurethane is a spray application, it shall be applied at a
thickness of I" (varies '/'). In this application 3 lbs. density foam will be used All urethane
will be coated properly with two separate coats of an acrylic coating. Both base and top coats
will consist of 2 gallons per 100 square feet giving a total of 4 gallons per 100 square feet
While the application of the top coat is being performed #11 sized granules will be embedded
into the wet surface at the rate of 50 lbs. per 100 square feet. The coating on all foamed vent
pipes will be terminated approximately 2" above the foam. This will supply us self -terminating
flashings and also giving a finished appearance. The building will gain an approximate R -value
of R-7 in this section of the ceiling insulation. This roofing system if recoated approximately
every ten - twelve years could last indefinitely. This roofing system meets or exceeds California
title 24 specifications.
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062
INKLEgra:
ROOF CONSTRUCTOR S
Sheet metal: RDW will supply and install the following sheet metal; Platform caps, Edge metal,
Scuppers, T -Top vents and vent pipe flashings as needed. If other sheet metal is desired to be
installed by RDW there will be an additional cost. Otherwise all other sheet metal is to be
supplied by and installed by others.
Equipment Removal and Reinstallation: All roof top AC units will be removed and
reinstalled. All equipment platforms will be raised to a minimum of 6" from the substrate. All
equipment platforms will receive a water barrier prior to the installation of the cap metal. The
new cap metal will be constructed from 24 gauge galvanized sheet metal.
Electrical Lines and Conduit: All the electrical to the equipment will be disconnected and
reinstalled. Any lines not installed in conduit that are required will be re -ran into new conduit.
Plumbing: All plumbing will be disconnected from the equipment and reinstalled. All damaged
vent pipes above the substrate will be repaired. All plastic drainage lines from the equipment that
are required to be copper will be replaced. We have provided an option for replacing all roof
drains, overflow drains and expansion cup links. This is highly recommend by RDW, the existing
drains are plastic and all overflow drains have been canceled. The existing expansion cup links
are the ribbed rubber boots, these boots break very offend which result in major interior water
damage.
Roof Drains and Overflows Drains: For the Thermoplastic Polyolefin (TPO) roofing system,
roof drains and overflow drains must be cast iron or copper with clamping rings. It is required
that the TPO roofing system have clamping drains. During the installation of the new drains all
visible expansion cup links will be replaced. This is included in the Thermoplastic Polyolefin
(TPO) roofing system (option #1)
Damaged Plywood & Fascia: Damaged plywood, board or other substrate will need to be
replaced. Since we cannot see if there is any or how much damaged wood there is this is not
included into the contract amount. RDW can remove and replace any damaged plywood sheeting
at $ 65.00 per sheet plus the cost of roofing. Other substrates will be removed and replaced at a
time and material based cost.
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062
www INKLO:
O
ROOF CONSTRUCTOR S
RDW Warranty: RDW will warranty the low -slope roofing system for a period of five years
(S). If the roofing systems are annually maintained in a Roof Maintenance Program by R D
Winkle Company during the applicable warranty period, the warranty for these roofing systems
will be extended to ten years (10). Please see WORKMANSHIP, MATERIALS AND SYSTEMS
WARRANTY for more information.
Thermoplastic Polyolefin (TPO) Roofing System (Option #1): $ 20,727.00
Annual Roof Maintenance Program: $-k- -
*An Additional Contract will be Provided for the Maintenance Program
Approval By:.
Signature:_
Respectfully Submitted,
C �
Ryan A. Winkle
Supervisor/Estimator
Date:
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062
INSTALLATION CERTIFICATE: Residential Reroof CF -6R -ENV -01
Site Address:
49040 Calle Flora, La Ounita CA. 92253
Enforcement Agency:
Permit Number:
If more than one person has responsibilityfor installation of the items on this certificate, each person shall prepare and sign a certificate
applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibilityfor construction shall
prepare and sign this certificate for the entire construction. All applicable Mandatory Measures with check boxes are required to be checked to
ensure the mandatory measures have been met.
CEILING INSULATION
Rigid: Brand Name:
Batt or Blanket Type: Brand Name:
Loose Fill Type: Thermal Resistance (R -Value):
Spray Foam Type: Brand Name:
Installed Actual Thickness (inches): Contractor's min installed weight/ftz
Manufacturer's installed weight per square foot to achieve Thermal Resistance (R -Value):
❑ § 150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor.
❑ § 118(a): Insulation installed meets Standards for Insulating Material.
❑ § 150(8): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
lb
ROOFING PRODUCTS (COOL ROOFS) §151O12
❑ Check this box if the newly installed roof is exempted from the roofing product "Cool Roof' requirements as indicated on the CF-1R-Alt-
Reroof form for this project. Otherwise fill in the table below.
L Roof Slope
Product Weight
Aged Solar
Thermal
t
CRRC Product ID Number
< 2:12 > 2:12
< 51b/ft2 > Slb/ft2
Product Type2
Reflectance3'4
Emittance
0628-0002'
53
1
❑
❑
❑
TPO
❑4
0.70
0.90
❑
❑
❑
❑
❑4
I. CRRC-1 label information is available is on the package of the roofing product being installed and attach the CRRC label to this form.
2. Indicate the type of product is being used for the roof top, i.e. single -ply roof, asphalt roof, metal roof, etc.
3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value frotn the
same directory and use the equation (0.2+0.7(p; ;,;�t — 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance.
4. Check box if the Aged Reflectance is a calculated value using the equation above.
To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
recommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)4. Select the applicable coating:
❑ Aluminum -Pigmented Asphalt Roof Coating
❑ Cement -Based Roof Coating
❑ Other
DECLARATION STATEMENT
• I certify under penalty of perjury; under the laws of the State of California, the information provided on this form is true and correct.
• I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative
of the person responsible for construction (responsible person).
• I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms
to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement
agency.
• I reviewed a copy of the Certificate of Compliance (CF -1R) form approved by the enforcement agency that identifies the specific
requirements for the installation. I certify that the requirements detailed on the CF -1R that apply to the installation have been met.
• I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building
permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a
signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building
owner at occupancy.
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
R D Winkle co.
Responsible Person's Name: Respo ible Person's Sign
Ryan A. Winkle
CSLB License: Date Signed: f4gon With Company (Title):
688062 11-18-2013
2008 Residential Compliance Forms August 2009
IFind rated products - Cool Roof Rating Council
1 SEARCH RESULTS
Selected filters
Manufacturer: Carlisle Construction Materials Incorporated
11/18/13 11:54 AM
PRINT EXPORT ALL PRODUCTS
CRRC PROD. ID MANUFACTURER. BRAND PRODUCT TYPE COLOR I SOLAR REFLECTANCE THERMAL EMITTANCE SRI MORE
MODEL INFO
initial 3 year initial 3 year initial 3 year
0628-0002 Carlisle Construction Materials Membrane: Single Bright White 0.79 0.70 0.90 0.86 99 85
Incorporated: Sure -Weld Ply Thermoplastic
TPO White and Thermoset
Roofing
COOL ROOF RATING COUNCIL 449 15th Street, Suite 200 Tel (866) 465-2523 Email: info a@coolroofs.orc)
Oakland, CA 94612 Fax (510) 482-4421
http://coolroofs.org/products/results Page 1 of 1
EvaluationIMES Report
QDLICC-ESIUL
Dual Report Reissued August 1, 2012
Click on the logo to access ut_ Certification This report is subject to renewal October 1, 2014.
www.icc-es.org 1 (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Section: 07 53 23—Ethylene-Propylene-Diene-Monomer
Roofing
Section: 07 54 19—Polyvinyl-Chloride Roofing
Section: 07 54 23—Thermoplastic-Polyolefin Roofing
l-400 1i.[0IA91*j
CARLISLE SYNTEC
PO BOX 7000
CARLISLE, PENNSYLVANIA 17013
(717) 245-7000
www.carlisle-syntec.com
EVALUATION SUBJECT:
CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING
MEMBRANES
ADDITIONAL LISTEES:
VERSICO
POST OFFICE BOX 1289
CARLISLE, PA 17013
(800) 992-7663
MULE -HIDE PRODUCTS COMPANY, INC.
1195 PRINCE HALL DRIVE
BELOIT, WISCONSIN 53511
(800) 786-1492
WEATHERBOND
POST OFFICE BOX 251
PLAINFIELD, PENNSYLVANIA 17081
(866) 471-5125
KELLY COMPANY/2001'INC.
325 THOMASTON AVENUE
WATERBURY, CONNECTICUT 06702
(203) 575-9220
1.0 EVALUATION SCOPE
Compliance with the following codes: -
■ 2009 International Building Code® (IBC) ,
■ 2009 International Residential Code® (IRC)
■ Other Codes (see Section 8.0)
Properties evaluated:
■ Weather resistance
■ Roof covering fire classification
■ Wind uplift resistance
■ Impact resistance .
2.0 USES
Carlisle ethylene , propylene diene monomer (EPDM),
polyvinyl chloride (PVC) and thermoplastic polyolefin
(TPO) single -ply roofing membranes are used as roof
coverings in. adhered and mechanically fastened
membrane roofing systems.
3.0 DESCRIPTION
3.1 General:
The EPDM, PVC and TPO Membrane Roofing Systems
described in this report consist of single -ply roofing
membranes, insulation where used, barrier board or slip
sheet where used, flashing, mechanical fasteners and
adhesives that are installed on a combustible or
noncombustible deck. See Table 1 for Carlisle product
trade names and corresponding product names for
Mule -Hide Products Company, Inc., WeatherBond, Versico
and Kelly Company/2001 Inc., the additional listees.
3.2 EPDM Membranes:
3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced
EPDM membrane, 45 mils thick [0.045 inch (1.14 mm)].
3.2.2 Sure -Seal FR: - Sure -Seal FR is a black,
nonreinforced EPDM membrane with fire retardants.
Available thicknesses range from 45 mils (0.045 inch
[1.14 mm]) to 90 mils (0.090 inch [2.29 mm]).
3.2.3 Sure -White: Sure -White is a white, nonreinforced
EPDM membrane. It is available in thicknesses of 60 mils
[0.060 inch (1.52 mm)] and 90 mils [0.090 inch (2.29 mm)].
3.2.4 Sure -Tough: Sure -Tough is a black, reinforced
membrane consisting of a. polyester reinforcement
encapsulated between two EPDM membrane plies. A is
available in thicknesses ranging from 45 mils [0.045 inch
(1.14 mm)] to 75 mils [0.075 inch (1.90 mm)].
3.2.5 Sure -Tough FR: Sure -Tough FR is a black,
reinforced membrane consisting of a polyester
reinforcement encapsulated between two EPDM
membrane plies with fire retardants. Available thicknesses
are 45 mils [0.045 inch (1.14 mm)] and 60 mils [0.060 inch
(1.52 mm)].
3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is
a 45 -mil to 90 -mil [0.045 inch to 0.090 inch (1.14 mm to
2.29 mm)] non -reinforced EPDM bonded to a 5.5 -ounce -
*Revised September 2013
1CC ESEvaluation Reports are not to be construed as represeming aenaherics or any other wribuies iron sp< cifuall), addressed, nor are rhes to be catsirued 'p N
as an errda setpertt oj'tltr suAiect of rlle.report,or� a.reContntet }dationfor its use. Vrere is no a arrancy ky ICC Evaluation Service, LLC, express or implied, as h
per -square -yard (0.18 kg /M2) polyester fleece. Available
product thicknesses range from 100 mils [0.100 inch
(2.55 mm)] to 145 mils [0.145 inch (3.68 mm)].
3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK
is a 45-, 60- or 90 -mil [0.045, 0.060 or 0.090 inch (1.14,
1.52 or 2.29 mm)] nonreinforced white EPDM bonded to a
5.5 -ounce -per -square -yard (0.18 kg/m2) polyester fleece.
Available product thicknesses are 100, 115 and 145 mils
[0.100, 0.115 or 0.145 inch (2.54, 2.92, or 3.68 mm)].
3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45 -mil
[0.045 inch (1.14 mm) or 60 -mil [0.060 inch (1.52 mm)]
non -reinforced EPDM bonded to a 7.5 -ounce -per -square -
yard (0.25 kg/m2) polyester fleece. Available thicknesses
are 90 mils [0.090 inch (2.29 mm)] and 105 mils
[0.105 inch (2.67 mm)].
3.3 PVC Membranes:
3.3.1 Sure -Flex and Sure -Flex KEE: Sure -Flex and
Sure -Flex KEE are membranes consisting of a polyester
reinforcement encapsulated between two plies of
PVC. The membrane is available in white,.gray, tan and
custom colors. Available thicknesses range from 50 mils
[0.050 inch (1.27 mm)] to 80 mils [0.080 inch (2.03 mm)].
3.3.2 Sure -Flex FRS: Sure -Flex FRS membrane
consists of a fiberglass reinforcement encapsulated
between two plies of PVC. The membrane is available in
white, gray and custom colors. Available thicknesses range
from 50 mils [0.050 inch (1.27 mm) to 80 mils [0.080 inch
(2.03 mm)].
3.3.3 Sure -Flex FleeceBACK: Sure -Flex FleeceBACK
is the Sure -Flex membrane, described in Sections 3.3.1
and 3.3.2, with a laminated 5.5 -ounce -per -square -yard
(0.18 kg/m2) polyester fleece backing. Available
thicknesses range from 105 mils [0.105 inch (2.67 mm)] to
135 mils [0.135 inch (3.43 mm)].
3.4 TPO Membranes:
3.4.1 Sure -Weld: Sure -Weld membrane consists of a
polyester reinforcement encapsulated between two plies of
TPO. The membrane is available,in white, gray, tan and
custom colors. Available thicknesses range from 45 mils
[0.045 inch (1.14 mm)] to 80 mils [0.080 inch (2.03 mm)].
3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld
membrane formulated with an additional flame retardant
for fire resistance at higher slopes. The membrane is
available in white, gray, tan and custom colors. Available
thicknesses are 45 mils (0.045 inch [1.14 mm]) and 60 mils
(0.060 inch [1.52 mm]).
3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of
the Sure -Weld HS membrane with adhesive.
3.4.4 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK
is the Sure -Weld HS membrane, 45 mils [0.045 inch
(1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils
[0.60 inch (2.03 mm)] thick, with a laminated 5.5 -ounce -
per -square -yard (0.18 kg /M2) polyester fleece backing.
Available thicknesses are 100 mils [0.1d0 inch (2.54 mm)],
115 mils [0.115 inch (2.92 mm)] and 135 mils [0.135 inch
(3.43 mm)].
3.4.5 Sure -Weld AFX: Sure -Weld AFX is the Sure -Weld
HS membrane with a laminated 10 -ounce -per -square -
yard (0.34 kg/m2) polyester fleece backing. Available
thicknesses range from 120 mils [0.120 inch (3.05 mm)] to
155 mils [0.155 inch (3.94 mm)].
3.4.6 Spectro-Weld: Spectro-Weld is the Sure -Weld
membrane, described in Section 3.4.1, formulated with a
3.4.7 Spectro-Weld FleeceBACK: Spectro-Weld
FleeceBACK is the Spectro-Weld membrane with a
laminated 5.5 -ounce -per -square -yard (0.18 kg/m2)
polyester fleece backing. It is 115 mils [0.115 inch
(2.92 mm)] thick.
3.5 Insulation:
See Tables 2 through 4 for insulations for use with specific
roofing systems. Foam plastic insulation, where used, must
have a flame -spread index of not more than 75 when
tested at the maximum`thickness intended for use in
accordance with ASTM E84.
3.6 Barrier Board:
Barrier board, where used, must be either minimum
1/4-irich-thick (6.4 - mm� G -P Gypsum Corporation
"DensDeck," minimum /4 -inch -thick (6.4 mm) Owens
Corning "Strataguard", -minimum 1/4 -inch -thick (6.4 mm)
USG "Securock," or minimum 1/2 -inch -thick (12.7 mm)
gypsum board. Barrier board must be UL -listed for roofing
applications or UL -classified gypsum board.
3.7 Slip Sheet:
The slip sheet, where used, must include Carlisle "FR
Base Sheet 1S or 2S," Elk "VersaShield Underlayment,"
Elk "VersaShield F8 -1S or FB -2S, or Atlas FR 10 or
FR 50."
3.8 Flashing:
Flashing must be provided in accordance with IBC Section
1503.2 or -IRC Section R903.2, as applicable. Where
flashing is of metal, the metal must be corrosion -resistant,
minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized
steel.
3.9 Fasteners:
Fasteners, used to mechanically attach insulation -and
membranes to the roof deck, must be corrosion -resistant,
and must be Carlisle fasteners, plates or fastening bars,
unless otherwise noted in this report. Refer to Table 4 for
spacing of fasteners.
3.9.1 HP Fastener: This is an epoxy -coated steel screw
used in combination with Carlisle's fastening plates or bars
to mechanically attach roofing insulation and membranes
to steel or wood substrate. Fastener length must be
selected to penetrate through the steel deck'a minimum of
3/4 inch (19.1 mm), and into the wood deck a minimum of
1 inch (25.4 mm).
3.9.2 InsulFast Insulation Fastener: This is an epoxy -
coated steel screw used in combination with Carlisle's
insulation plates to mechanically attach roofing insulation
to steel or wood substrates. Fastener length must be
selected to penetrate through the steel deck a minimum of
3/4 inch (19.1 mm), or into the wood deck a minimum of
1 inch (25.4 mm).
3.9.3 HP Purlin Fastener:. This is an epoxy -coated steel
screw used in combination with Carlisle's fastening plates
or bars to mechanically attach roofing insulation and
membranes to structural steel members. Fastener length
must be selected to penetrate through the steel member a
minimum of 3/4 inch (19.1 mm.)
3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy -
coated steel screw used in combination with Carlisle's
fastening plates or bars to mechanically attach roofing
insulation and membranes to concrete roof deck. Fastener
length must be selected to penetrate into the concrete
deck a minimum of 1 inch (25.4 mm).
designed to be used with insulation and seam fastening
plates to secure membrane and insulation to structural
concrete. Fastener length must be selected to penetrate
into the concrete deck a minimum of 1 inch (25.4 mm).
3.9.6 Lite -Deck Fastener: The Lite -Deck Fastener, is
used in conjunction with a specially designed 3 -inch
(76.2 mm) Lite -Deck Metal Plate for. insulation attachment
to gypsum, cementitious wood fiber (Tectum [ESR -1112j),
and lightweight concrete decks. Fastener length must be
selected to penetrate into the deck a minimum of 2 inches
(50.8 mm). '
3.9.7 GypTec Fastener: The GypTec Fastener is a
glass -filled nylon auger fastener designed for securing
mechanically attached membranes and insulation to
gypsum and cementitious wood fiber (Tectum [ESR -1112])
decks. Fastener length must be selected to penetrate into
the deck a minimum of 1.5 inches (38.1 mm).
3.9.8 HP Polymer Seam Plate: This is a 2 -inch -diameter
(50 mm) polymer plate designed to be used with HP and
HD 14-10 fasteners to mechanically attach roofing
membranes to the roof deck.
3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is
a heavy-duty, epoxy -coated steel screw and bar used to
secure reinforced EPDM membranes to steel or wood
deck. The bar is 1 -inch -wide -by -0.040 -inch -thick -by -
10 -foot -long (25.4 mm by 1.1 mm by 3.1 m) galvalume-
coated steel with prepunched holes 6 inches (150 mm)
on center.
3.9.10 HP -X Fastener: This is an epoxy -coated carbon
steel screw used in combination with the Piranha
Fastening Plate to mechanically attach TPO membranes to
steel or wood substrate. Fastener length must be selected
to penetrate through the steel deck a minimum of 3/4 inch
(19.1 mm), and into the wood deck a minimum of 1 inch
(25.4 mm).
3.9.11 Piranha Fastening Plate: This is a 23/8 -inch -
diameter galvalume-coated steel plate designed to be used
with HP -X fasteners to mechanically attach PVC and TPO
membranes to the roof deck.
3.9.12 HP-XTRA Fastener: This is an epoxy -coated
carbon steel screw used in combination with the Piranha
XTRA Fastening Plate to mechanically attach PVC and
TPO membranes to steel or wood substrate. Fastener
length must be selected to penetrate through the steel
deck a minimum of 3/4 inch (19.1 mm) and into the wood
deck a minimum of 1 inch (25.4 mm).
3.9.13 Piranha XTRA Fastening Plate: This is a
23/8 -inch -diameter galvalume-coated steel plate designed
to be used with HP-XTRA fasteners to mechanically attach
PVC and TPO membranes to the roof deck.
3.9.14 PVC Oval Barbed Plate: This is a 11/2 -inch -by -
23/4 -inch (35 mm by 69.85 mm) Oval Barbed Plate
designed to be used with HP -X Fasteners to mechanically
attach PVC membranes to the roof deck.
3.9.15 OMG Inc. RhinoBond Plate: The RhinoBond Plate
is a 3 -inch -diameter (76.2 mm), 0.028 -inch -thick (0.7 mm)
galvalume-coated steel plate, coated with a proprietary
adhesive and used with the HP -X fastener to mechanically
attach PVC and TPO membranes to the roof deck. The
adhesive bonds the plate to the underside of the
membrane.
3.10 Adhesives:
3.10.1 90-830A Bonding Adhesive: 90-8-30A Bonding
insulation or substrate. It has a coverage rate of
approximately 60 square feet per gallon (1.5 M2 /Q. The
adhesive is supplied in 5 -gallon (18.9 L) containers and
has a shelf life of one year.
3.10.2 Aqua Base 120: Aqua Base 120 is a high-strength,
water-based contact adhesive used to adhere EPDM, TPO
and PVC membranes to the insulation or substrate. It has
a coverage rate of approximately 120 square feet per
gallon (3 m2/L). The adhesive is supplied in 5 -gallon
(18.9 L) containers and has a shelf life of one year.
3.10.3 Sure -Flex low-VOC PVC Bonding Adhesives:
Sure -Flex Low VOC PVC Bonding Adhesives is high-
strength, solvent -based contact adhesives used to adhere
PVC membranes to an insulation or substrate. They have
a coverage rate of approximately 60 square feet per gallon
(1.5 m2/L). The adhesive is supplied in 5 -gallon (18.9 L)
containers with a shelf life of one year.
3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld
Bonding Adhesive is a high-strength, solvent -based
contact adhesive used to adhere TPO membranes to
an insulation or substrate. It has a coverage rate of
approximately 60 square feet per gallon (1.5 m2 /L). The
adhesive is supplied in 5 -gallon (18.9 L) containers with a
shelf life of one year.
3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding
Adhesive is a high-strength, solvent -based contact
adhesive used to adhere EPDM and TPO membranes to
an insulation or substrate. It has a coverage rate of
approximately 60 square feet per gallon (1.5 m2/ Q. The
adhesive is supplied in 5 -gallon (18.9 L) containers with a
shelf life of one year.
3.10.6 HydroBond PVC Water -Based Adhesive:
HydroBond PVC Water -Based Adhesive is a water-based,
wet lay -in, one-sided adhesive to be used to adhere Sure -
Flex PVC and PVC FleeceBACK membranes to an
insulation or substrate. It has a coverage rate of
100 square feet per gallon (2.5 m2/L). The adhesive is
supplied in 5 -gallon 918.9 L) containers with a shelf life of
one year.
3.10.7 Low VOC Bonding Adhesive 1168: Low VOC
Bonding Adhesive 1168 is high-strength, solvent -based
contact adhesive used to adhere EPDM and TPO
membranes to an insulation or substrate. It has a coverage
rate of approximately 60 square feet per gallon (1.58 m2/L).
The adhesive is supplied in 5 -gallon (18.9 L) containers
with a shelf life of one year.
3.10.8 Solvent -Free EPDM Bonding Adhesive: Solvent -
Free EPDM Bonding Adhesive is a high-strength, polymer -
based adhesive. This adhesive can be used to adhere all
Sure -Seal or Sure -White EPDM membranes as a one-
sided, wet lay -in adhesive. It has a coverage rate of
100 square feet per gallon (2.5 m2 /L). The adhesive is
supplied in 5 -gallon (18.9 L) containers with a shelf life of
six months.
3.10.9 Cold Applied Adhesive: Cold Applied Adhesive is
a solvent -free, asphalt -modified polyether adhesive. This
adhesive can be used with all Sure -Seal or Sure -Weld AFX
membranes as a one-sided, wet lay -in adhesive. It has a
coverage rate of 67 square feet per gallon (1.6 m2 /Q. The
adhesive is supplied in 5 -gallon (18.9 L) containers with a
shelf life of one year.
3.10.10 FAST Adhesives: FAST 100, FAST 100LV,
FAST Adhesive Dual Cartridge, FAST Adhesive Box Sets,
Flexible FAST and FAST Bag -in -a -Box Adhesives are two -
substrates. The adhesives have a coverage rate of
approximately 100 square feet per gallon (2.5 m2 /L). The
adhesives are supplied in 15 -gallon (56.7 L) and 50 -gallon
(189 L) drums, box sets, and cartridge tubes and cylinders,
and have a shelf life of one year.
3.10.11 OlyBond 500 Adhesive: OlyBond 500 Spot Shot
and OlyBond 500 BA are two -component polyurethane
adhesives used to adhere . insulations to various
substrates. The adhesives have a coverage rate of
approximately 100 square feet per gallon (2.5 m2/L). The
adhesives are supplied in cartridge tubes and box sets,
and have a shelf life of one year.
3.11 Impact Resistance:
The EPDM, PVC, and TPO roofing membranes described
in this report meet requirements for impact resistance in
IBC Section 1504.7, based on testing in accordance with
FM 4470.
4.0 INSTALLATION
4.1 General:
Installation of the EPDM, PVC, and TPO roofing
membranes described in this report must comply with the
applicable code, the manufacturer's published installation
instructions and this report. The manufacturer's published
installation Jnstructions must be available at all times on
the jobsite during installation.
The substrate to which the membrane is to be applied
must be clean, dry, and free of frost, loose fasteners, and
other protrusions or contaminates that will interfere with the
adhesion or attachment of the membrane or that will
puncture the membrane. All materials must be protected
against contact with incompatible materials. Where
gypsum board is used as barrier board in the roofing
assembly, weather protection must be provided to prevent
damage to the gypsum board prior to application of the
roofing membrane.
The slope of the roof on which the single -ply membranes
are installed must not be more than the maximum slope
indicated for the particular assembly as listed in Tables 2
and 3.
Penetrations and terminations of the roof covering must
be flashed and made weather tight in accordance with the
requirements of the membrane manufacturer and the
applicable code.
4.2 Fire Classification:
4.2.1 New Construction: The adhered and mechanically
fastened EPDM, -PVC, and TPO single -ply membrane
roofing systems, when installed in accordance with this
report, are Class A, B or C roof covering systems in
accordance with ASTM E108 or UL 790, as noted in
Tables 2 and 3.
4.2.2 Reroofing: The existing deck must be inspected to
verify that the structure to be reroofed is structurally sound
and adequate to support and secure the roofing
membrane. Prior to installation of new roof coverings,
inspection by and written approval from the code official
having jurisdiction must be required.
Class A, B or C roof covering systems may be installed
over existing classified roof covering systems under the
following conditions without additional roof classification
tests, provided the resulting classification is the lower of
the new or existing roofing classification:
■ NPw uninsiilatad systams installed only nver axistinn
■ New insulated . systems installed over existing
uninsulated systems only.
4.3 Wind Resistance:
4.3.1 New Construction: The allowable wind uplift
pressures for the EPDM, PVC, and TPO roofing
membranes as parts of roof assemblies are noted in
Tables 4 and 5.
Metal edge securement for roofing systems must be
designed in accordance with ANSI/SPRI ES -1, complying
with IBC Section 1504.5. The edge securement for
mechanically attached membranes was tested in
accordance with ANSI/SPRI ES -1 Test RE -1, using
Carlisle SecurEdge 300 [0.050 -inch (1.27 mm) 3003
aluminum] and Carlisle- SecurEdge 3000 [0.040 -inch
(1.02 mm) 3003 aluminum] fascia systems. The maximum
allowable load for Carlisle SecurEdge 300 is 234 plf
(348 kg/m). The maximum allowable load for Carlisle
SecurEdge 3000 is 200 plf (298 kg/m).
4.3.2 Reroofing: Mechanically anchored systems may
be accepted based on the adequacy of anchors
penetrating through existing roof coverings into structural
substrates. Since the composition and/or condition of any
particular existing underlying material may vary widely,
reroofing with adhered systems is outside the scope of this
report.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing membranes
described in this report comply with, or are suitable
alternatives to what is specified in, those codes listed in
Section 1.0 of this report, subject to the following
conditions:
5.1 Installation must comply with the applicable code, the
manufacturer's published installation instructions and
this report. The instructions within this report must
govern if there are any conflicts between the
manufacturer's installation instructions and this report.
5.2 The adhered and mechanically fastened single -ply
membrane roofing systems must be installed by
professional roofing contractors who are trained and
approved by the manufacturer.
5.3 Foam plastic insulation must be separated from' the
interior of the building by an approved thermal barrier
in accordance with IBC Section 2603.4.1.5 or IRC
Section R314.4, as applicable.
5.4 Foam plastic insulation, where used, must bear the
label of an approved agency indicating that the foam
plastic has a flame -spread index of not more than 75
when tested at the maximum thickness intended for
use in accordance with ASTM E84, subject to the
approval of the code official.
5.5 Design wind uplift pressure on any roof area,
including edge and corner zones, must not exceed
the allowable wind uplift pressure for the system
installed in that particular area. Refer to allowable
wind uplift pressures for systems as listed in Table 4.
5.6 The allowable wind uplift pressures listed in Table 4
are for the roof covering' system only. The deck and
framing to which the system is attached must be
designed for the applicable components and cladding
wind loads in accordance with the applicable code.
5.7 When application is over existing roofs,
documentation of the wind -uplift resistance of the
composite roof construction must be submitted to the
nnrla nffininl fnr annrnval at tha times of narmit
5.8 The roofing membranes are manufactured at Carlisle,
Pennsylvania; Greenville, Illinois; Tooele, Utah; and
Senatobia, Mississippi, • under a quality control
program with inspections by UL LLC (AA -668).
5.9 For buildings under the IBC, aboveAeck thermal
insulation board must comply with the applicable
standards listed in Table 1508.2 of the IBC.
6.0 EVIDENCE SUBMITTED
Data in accordance with ICC -ES Acceptance Criteria
for Membrane Roof Covering Systems (AC75), dated
July 2010.
7.0 IDENTIFICATION
Each roll of the roofing membrane must bear a label noting
the product name, the manufacturer's name (Carlisle
SynTec) _or the name of the additional listee, the
manufacturer's address or plant code, the ICC -ES
evaluation report number (ESR -1463), and the name or
label of the inspection agency (UL LLC).
8.0 OTHER CODES
In addition to the codes referenced in Section 1.0, the
products in this report were evaluated for compliance with
the requirements of the following codes:
■ BOCe National Building Code/1999 (BNBC)
■ 1999 Standard Building Code® (SBC)
■ 1997 Uniform Building CodeTm (UBC)
For compliance under the above codes, see Sections 2
through 7 of this report, except revise the following
sections to read as follows:
0.0oll 1.
3.8 Flashing:
Flashing must be provided in accordance with SBC
Section 1503.2, BNBC Section 1508.1 and UBC Section
1509, as applicable. Where flashing is of metal, the metal
must be corrosion -resistant, minimum No. 26 gage
[0.019 inch (0.483 mm)) galvanized steel.
3.11 Impact Resistance:
The EPDM, , PVC, and TPO roofing membranes
described in this report meet requirements for impact
resistance in BNBC Section 1505.4.2, and SBC Section
1504.6, based on testing in accordance with FM 4470.
4.3.1 New Construction: The allowable wind uplift
pressures 'for the EPDM, PVC, and TPO roofing
membranes as parts of roof assemblies are noted in
Tables 4 and 5.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing
membranes described in this report comply with, or are
suitable alternatives to what is specified in, those codes
listed in Section 8.0 of this report, subject to the following
conditions: f
See Sections 5.1 through 5.8, except revise Section
5.3 to read as follows:
5.3 Foam plastic insulation must be separated from the
interior of the building by an approved thermal barrier in
accordance with BNBC Section 2603.4.1.5, SBC Section
2603.5.1.5, and UBC Sections 2602.4 and 2602.5.3, as
applicable.
3K±:Ci'�eil
T-014
.fidC;:` i:`a..DiliSi:.4+Y:'E
i;1J�':I. I~'� saiY*dS�� �''�altL`S'I,9I'i 4i� � .:112'b^CS43 a a.711•C<.;.S:.P}°
to
t
rfe�,xal,�a-,axz �cai'i?i:��asaaa<• *��."�f.�"el:S
f Cy E :i'4ti:ttkP4 of PAq4to Ctrzifitki fin.�{,�wN+d:_,
;: L..�f;: }its-��kic�. «A•Jz���is ai�xfl Sy��a:�zw �5i�crs_iat
FIGURE 1—INSPECTION AGENCY LABEL
TABLE 1—PRODUCT NAMES
CARLISLE PRODUCT
MULE -HIDE PRODUCT
WEATHERBOND PRODUCT
VERSICO PRODUCT NAME
KELLY CO./
NAME
NAME
NAME
'
2001 INC.,
r
PRODUCTNAME
Sure -Seal
Mule -Hide Standard EPDM
WeatherBond RBR EPDM Non-
Versigard Non -reinforced
PREMIUM', C=EPDM-C
reinforced Membrane
EPDM Membrane
STANDARD.
Sure -Seal FR
Mule -Hide FR EPDM
-WeatherBond RBR FR EPDM
VefsiGard FR Nonreinforced
C-EPDM-C
Non -reinforced Membrane
EPDM
Sure -Seal Fleece BACK
VersiFleece EPDM Membrane
PREMIUM
Sure -Seal AFX
VersiFleece AC EPDM
Membrane '
Sure -Tough Reinforced
Mule -Hide Standard
WeatherBond RBR Standard
Versigard Reinforced
PREMIUM, C-EPDM=C,
Reinforced EPDM
Reinforced EPDM Membrane
EPDM Membrane
STANDARD, C-EPDM-CR
Sure -Tough FR
Mule-Hide FR Reinforced
WeatherBond RBR FR
VersigardFR Reinforced
C-EPDM-CR Type 1
Reinforced
EPDM
Reinforced EPDM Membrane
1r 1''
Sure -White
Mule -Hide White -on -Black
WeatherBond RBR White EPDM
Versigard Nonreinforced EPDM
PREMIUM, EPDM RF -
EPDM
Membrane
-White
White
Sure -White
Fleece BACK
Sure -Weld
Mule -Hide TPO-c
WeatherBond PRO TPO
Versiweld Reinforced TPO
' Reinforced TPO /White
Membrane
Membrane
TPO
Sure-Weld
Sure -Weld HS
Mule -Hide TPO-c (FR)
Versiweld ES
SAT-TPO
Mule -Hide SA-TPO
WeatherBond PRO PAS TPO
Versiweld OA TPO
Sure -Weld Fleece BACK
Mule -Hide TPO-c Fleece
VersiFleece TPO Membrane
Back
'Sure -Weld AFX
Mule -Hide TPO-C Fleece
VersiFleece AC TPO
Back Plus
Membrane
Spectro-Weld
7`
Spectro-Weld
FleeceBack
Sure -Flex
Mule -Hide PVC Membrane
WeatherBond PRO PVC
VersiFlex Reinforced PVC
Membrane
Sure -Flex KEE
VersiFlex-E PVC Membrane
Sure -Flex FRS
Mule -Hide FRS PVC
VersiFlex FRS Reinforced PVC
Membrane
Membrane
Sure -Flex FleeceBack
VersiFleece PVC Membrane
90-8-30A Bonding
Mule -Hide Bonding Adhesive
WeatherBond RBR LC -60
G200SA Yellow Substrate
2001 Inc. Bonding Adhesive
Adhesive
Bonding Adhesive
Adhesive
Solvent -Free EPDM
Solvent -Free EPDM Bonding
Solvent -Free EPDM Bonding
Bonding Adhesive
Adhesive
Adhesive
Aqua Base 120 Bonding
Mule -Hide WBBA-2000
Aqua Base 120 Bonding
Aqua Base 120 Bonding
Adhesive
Bonding Adhesive
Adhesive
Adhesive
Sure -Weld Bonding
Mule -Hide TPO-c Bonding
WeatherBond PRO TPO
Versiweld Bonding Adhesive
Adhesive
Adhesive
Bonding Adhesive
Low VOC Bonding
Mule -Hide Low VOC Bonding
LOW VOC Bonding Adhesive
LOW VOC Bonding Adhesive
Adhesive
Adhesive
Low VOC Bonding
Low VOC Bonding Adhesive
Low VOC Bonding Adhesive
Adhesive 1168
1168
1168
Sure -Flex Low VOC
Mule -Hide Low VOC PVC
WeatherBond Low VOC PVC
VersiFlex Low VOC PVC
PVC Bonding Adhesive
Bonding Adhesive
Bonding Adhesive
Bonding Adhesive
Hydro Bond PVC Water-
Hydro Bond PVC Water -Based
HydroBond PVC Water -Based
Based Adhesive
Adhesive
Adhesive
Cold Applied Adhesive
Cold Applied Adhesive
FAST 100 Adhesive
Mule -Hide SP -100 Adhesive
FAST 100 Adhesive
FAST 100 LV Adhesive
Mule -Hide SP -100 -LT
FAST 100 LV Adhesive
Adhesive
OlyBond 500 Adhesive
OlyBond 500 Adhesive
OlyBond 500 Adhesive
TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS25
SYSTEM
.ROOF
DECK
BARRIER BOARD
INSULATION'
MEMBRANEIMAX. ROOF SLOPE
NO.
CLASS
OR SLIP SHEET
Sure -Weld, Spectro-Weld -'/4:12
Any of the following insulations,
Sure -Seal, Sure -Tough, Sure -White, Sure -
1 -inch min. to 6 -inch max.
thickness: Carlisle "SecurShield
Seal FleeceBACK, Sure -Weld HS, SAT-TPO,
1
A
Noncombustible
Polyiso", "Polyiso HP -H", Hunter
"H
Sure -Weld FleeceBACK�Spectro-Weld
FleeceBACK - /2:12
Panels -Shield" or
"H -Shield -CG"
Sure -White FleeceBACK Sure -Flex, Sure -
Flex FRS - /4:12
1/2 -inch -thick fiberboard 4,'/2 -inch-
Sure -White FleeceBACK-'/4:12
/4:
thick fiberboard or barrier board
(see Section 3.6) 03e� 5 -inch
Sure -Seal, Sure -Tough - 2
2
A
Noncombustible
—
EPS /2 inch-
max Iberboa
Sure -White, Sure -Seal FleeceBACK, Sure -
,
thick fiberboard or barrier board
d
Weld, Spectro-Weld, Sure -Weld HS, SAT -
(see Section over System
TPO, Sure --Weld FleeceBACK, Spectro-Weld
No. 1 insulations
nsu
FleeceBACK, Sure -Flex, Sure -Flex FRS -
1,/2:12
Sure -White FleeceBACK-3/4:12
Sure -White, Sure -Seal FleeceBACK - 11/2:12
Noncombustible or
Combustible -min.
Sure -Tough, Sure -Weld, Spectro-Weld, Sure -
3
A
15/32-inch4hick
Barrier board
—
Weld FleeceBACK, Spectro-Weld
plywood or min.
(see Section 3.6)
FleeceBACK - 3:12
'/18 -inch -thick OSB.
Sure -Weld HS, SAT-TPO - 4:12
Sure -Seal FR, Sure -Flex, Sure -Flex FRS –
unlimited slope
Any of the following insulations,
Sure -Weld, Spectro-Weld -'/4:12
Combustible - min.
Barrier board
1 -inch min.
Sure -Seal, Sure -Tough, Sure -White, Sure -
15
/32 inch -thick
(see Section 3.6) or
to 6 -inch max. thickness:
"SecurShield
Seal FleeceBACK, Sure -Weld HS, SAT-TPO,
4
A
7/ plywood or min.
Slip sheet: 2 layers
Carlisle Polyiso",
Polyiso HP -H",
Sure -Weld FleeceBACK, Spectro-Weld
FleeceBACK -'/2:12
,e -inch -thick OSB.
(see Section 3.7)
Hunter Panels "H -Shield" or
Sure -White FleeceBACK, Sure -Flex, Sure -
"H -Shield -CG"
Flex FRS -3/4:12
Combustible - min.
1513rinch4hick
Any of the following insulations,
Sure -Weld, Spectro-Weld, Sure -Weld HS,
5
C
_
2 -inch min. to 6 -inch max.
SAT-TPO, Sure -Flex, Sure -Flex FRS –
plywood or min.
7/ plywood
thickness: Carlisle "Polyiso HP-
"H
unlimited slope
OSB.
H" or Hunter Panels -Shield"
Single layer of minimum 3.0" or
double layer of minimum 1.5"
6
A
Combustible
—
Carlisle "SecurShield Polyiso" or
EPDM, PVC, and TPO Membranes -1/2:12
Hunter Panels
"H -Shield -CG"
Single layer of minimum 1.9"
7
B
Combustible
—
Carlisle "SecurShield Polyiso" or
EPDM, PVC, and TPO Membranes -'/2:12
Hunter Panels
"H -Shield -CG"
For SI: 1 inch = 25.4 mm.
1 All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
2See Section 3.10 for adhesive application rate.
3 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope 1:12) or below
min. 1/2 -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
4Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. '/2:12.
5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
TABLE 3—FIRE CLASSIFICATION ASSEMBLIES -MECHANICALLY FASTENED ROOFING SYSTEMS°
SYSTEM
ROOF
DECK
BARRIER BOARD
INSULATION'
MEMBRANE/MAX: ROOF
NO,
CLASS
OR SLIP SHEET
'
SLOPE
Any of the following insulations, 1 -inch min. to
Sure -Tough, Sure -Weld,
1
A6
Noncombustible
-inch max. thickness: Carlisle "SecurShield
"Polyiso
Spectro-Weld, Sure -Flex, Sure -
Flex FRS - /2:12
Polyiso" or HP -H", Hunter Panels "H-
"H
,
Sure -Weld HS - 11/212
Shield" or -Shield -CG"
Sure -Tough FR - 2:12
1/2 -inch -thick fiberboard 3,'/2 -inch -thick
Sure -Tough, Sure -Weld HS,
fiberboard or barrier board (see Section -3.6)
Sure -Flex, Sure -Flex FRS - 1:12
2
A
Noncombustible
—
over 5 -inch max Insulfoam EPS2,'/.-inch-thick
Sure -Weld, Spectro-Weld -
fiberboard or barrier board (see Section 3.6)
1'/2:12
over System No. 1 insulations
Sure -Tough FR - 3'/2:12
Sure -Weld, Spectro-Weld, Sure -
3
A
Noncombustible
—
To 5 -inch max: Insulfoam SP
Weld HS, Sure -Flex, Sure -Flex
FRS -'/2:12
Noncombustible or
Sure -Tough, Sure -Weld,
Combustible - min.
15/32
Barrier board
Spectro-Weld - 3:12
4
A
-inch -thick
(see Section 3.6)
_
Sure -Tough FR - 31/2:12
plywood or min.
Sure -Weld HS, Sure -Flex, Sure -
7/16 -inch -thick OSB.
Flex FRS - unlimited
Combustible - min.
Barrier board
Any of the following insulations, 1 -inch min.
Sure -Tough, Sure -Weld,
,s/g2-inch-thick
(see Section 3.6)
to 6 -inch max. thickness: Carlisle
Spectro-Weld, Sure -Flex, Sure -
,
5
A
plywood or min.
or Slip sheet: 2
"SecurShield Polyiso" or "Polyiso HP -H",'
Flex FRS - 12:12
7/1 s -inch -thick OSB.
layers, (see Section
Hunter Panels
Sure -Weld HS, 1'/2:12
3.7)
"H -Shield" or "H -Shield -CG"
Sure=Tough FR - 2:12
Combustible -min.
Sure -Tough - 1:12
,s
/32 -inch -thick
Slip sheet, 2 layers
Sure -Tough. FR, Sure Weld,
6
A
plywood..or min.
(see Section 3.7)
—
Spectro-Weld, Sure -Weld HS,
/,e -inch -thick OSB.
Sure -Flex, Sure -Flex FRS -
02:12
Combustible - min.
Sure -Tough, Sure -Tough FR,
7
B
15/3. -inch -thick
. Slip sheet, 1 layer
—
Sure -Weld, Spectro-Weld,
plywood or min.
(see Section 3.7)
Sure -Weld HS, Sure -Flex, Sure -
'/,6 -inch -thick OSB.
Flex FRS - 11/2:12
Combustible -min.
Any of the following insulations, 2 -inch min'. j
,s/32 -inch -thick
to 6 -inch max. thickness: Carlisle
"Polyiso
Sure -Weld, Spectro-Weld,
8
C
—
"SecurShield Polyiso" or
Sure -Weld HS, Sure -Flex, Sure -
plywood or min.
/,e -inch -thick OSB.
HP -H", Hunter Panels "H -Shield" or H -Shield.
Flex FRS - unlimited
CG"
Single layer of minimum 3 -inch or double layer
9
A
Combustible
—
of minimum 1.5 -inch Carlisle
"SecurShield Polyiso" or
EPDM, PVC, and TPO
Membranes -'/2:12
Hunter Panels "H -Shield -CG"
Single layer of minimum 1..9 -inch Carlisle
10
B
Combustible
"SecurShield Polyiso" or Hunter Panels "H-
EPDM, PVC, and TPO
_
Shield -CG" or single layer of an inverted G3
Membranes - /2:12
cap sheet.'
For SI: 1 inch= 25.4 mm.
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
2 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below
min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
3Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as'a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to' /2:12.
"When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
TABLE 4—WIND RESISTANCE—MECHANICALLY FASTENED'ASSEMBLIES°''
SYSTEM
MAXIMUM
DECKS
INSULATION 5
MEMBRANE
MEMBRANE
MAXIMUM
MAXIMUM
NO.
ALLOWABLE
FASTENING
FASTENER
FASTENER
WIND UPLIFT
SPACING
ROW
(psf)
(inches)
SPACINGs
Foam plastic insulation'''4
'/z-inch4hick fiberboards or
H P -X Fastener &
1
45
Noncombustible
barrier board
Sure -Tough
Metal Fastening Bar
12
6 ft 6 inches
(See Sect. 3.6)
2
•75
Noncombustible
Same as System No. 1
Sure -Tough
Hal Fastener &
6
6 ft 6 inches
Mettal Fastening Bar
3
52
Noncombustible
Same as System No. 1
Sure -Tough
Fastener &mer
6
9 It 6 inches
Poy
PolySeam Plate
4
45
Noncombustible
Same as System No. 1
Sure -Tough
Sure-Tite Fastener &
12
9 It 6 inches
ST Fastening Bar
5
30
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
12
9 It 6 inches
(75 mil)
Polymer Seam Plate
- 6
-60
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
6
9 ft 6 inches
(75 mil)
Polymer Seam Plate
Sure -Weld or
HP -X or HP -Xtra
7
45
Noncombustible
Same as System No. 1
Spedro-Weld
Fasteners with Piranha
12
7 ft 6 inches
or Piranha Xtra Plates
8
45
Noncombustible
Same as System No. 1
Sure -Weld or
HP -Xtra Fasteners with
12
9 It 6 inches
Spedro-Weld
Piranha Xtra Plates
H P -X or H P -Xtra
9
60
Noncombustible
Same as System No. 1
Sure -Weld or
Fasteners with
6
9 ft 6 inches
Spedro-Weld
Piranha or Piranha Xtra
Plates
Sure -Weld or
HP -X or HP -Xtra
10
67
Noncombustible
Same as System No. 1
Spedro-Weld
Fasteners with Piranha
6
7 It 6 inches
or Piranha Xtra Plates
Sure -Weld or
HP -X or HP -Xtra
11
30
Noncombustible
Same as System No. 1
Spedro-Weld
Fasteners with Piranha
12
11 ft 6 inches
or Piranha Xtra Plates
Sure -Weld or
HP -X or HP -Xtra
12
60
Noncombustible
Same as System No. 1
Spedro-Weld
Fasteners with Piranha
6
11 ft 6 inches
or Piranha Xtra Plates
13
53
Noncombustible
Same as System No. 1
Sure -Flet
HP -X Fasteners with
6
6 ft 4 inches
Piranha Plates
14
83
Noncombustible
Same as System No. 1
Sure -Flex
HPFasteners with
6
2 ft 11 inches
P
Piranha Plates
H P -X or H P -Xtra
15
30
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
18
6 ft 4 inches
or Piranha Xtra Plates
HP -X or HP -Xtra
16
45
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
12
6 ft 4 inches
or Piranha Xtra Plates
17
53
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
12
2 ft 11 inches
Piranha Plates
18
45
Noncombustible
Same as System No. 1
Sure -Weld
HP -X Fasteners with
1 per 5.3 ft
N/A
OMG RhinoBond Plates
19
60
Noncombustible
Same as System No. IT
Sure -Weld
HP -X Fasteners with
1 per 4 ft2
N/A
OMG RhinoBond Plates
For SI: 1 inch = 25.4 mm; 1 It = 0.305 m; 1 psf = 47.88 Pa.
'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShield Polyiso" "Polyiso HP -H" Hunter Panels
"H -Shield" or Hunter Panels "H -Shield- CG".
2AII foam plastic insulation must be UL -classed foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with
Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
3Steel deck must be minimum No. 22 gage galvanized steel (base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive
strength (Q of 2500 psi. See Section 5.6 of this report.
°For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle iron, beams,
etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2.
5UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min. 1/7 -inch -
thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
6Carlisle SecurShield HD or Hunter Panels HShield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two
boards are used directly below the Sure -Weld membrane, the slope is limited to 1/212.
7 When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section
1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
8 Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies. The
maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum allowable load for Carlisle SecurEdge 3000 is 200 plf
(298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly.
TABLE 5—{MND RESISTANCE—ADHERED'ASSEMBLIESS
SYSTEM
ALLOWABLE
DECK2
INSULATION / MIN. THICKNESS'''
INSULATION
MEMBRANE
NO.
WIND UPLIFT
FASTENING
TYPE
(FIELD) (psf)
RATE
1
45
Combustible or
1/2 inch fiberboard 4,15/32inch OSB, or barrier board
1 per 2112
p
EPDM, PVC and TPO
Noncombustible
(See Section 3.6)
Membranes
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso";
EPDM, PVC and TPO
2
45
Noncombustible
Hunter Panels "H -Shield" or "H -Shield -CG" / 1.4 inch
; 1 per. 3.2 It
Membranes
with'/2-inch Securock coverboard (optional)
3
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso";
Hunter "H or "H 2.0 inch
EPDM, PVC and TPO
45
Noncombustible
Panels -Shield" -Shield -CG" /
with 5/e -inch Securock coverboard (optional)
1 per 4 ftz
Membranes
4
68
Combustible or
Carlisle "Polyiso HP -W or "SecurShield Polyiso";
FAST Adhesive
FleeceBACK Membranes
Noncombustible
Hunter Panels "H -Shield" or "H -Shield -CG" / 1.0 inch
Combustible or
Carlisle "Polyiso HP -H" or"SecurShield Polyiso';
"H "H
z
EPDM, PVC and TPO
5
75
Noncombustible
Hunter Panels -Shield" or -Shield -CG" / 2.0 inch
1 per 1.6 ft
Membranes
with'/Tinch Securock coverboard (optional)
TPO Membranes;
6
120
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso";
"H "H
1er.1 ft
p
EPDM membranes (with
Noncombustible
Hunter'Panels -Shield" or -Shield -CG" / 2.0 inch
noncombustible deck
only)
7
128
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso";
Hunter Panels "H "H / 2.0 inch
z
1 1 ft
EPDM and TPO
Noncombustible
-Shield" or -Shield -CG"
per
Membranes
f with '/z -inch Securock coverboard (optional)
Combustible or
'Carlisle "Polyiso HP -H" or "SecurShield Polyiso";
8
135
Noncombustible
Hunter Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 per 1 ftz
FleeceBACK Membranes
+ . with 1/2 -inch Securock coverboard (optional)
9
143
Combustible or
1/2 inch DensDeck Prime
1 per 1-ft2
FleeceBACK Membranes
Noncombustible
For SI: 1 inch = 25.4 mm; 1 It = 0.305 m; 1 psf = 47.88 Pa
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this reportor the maximum thickness in accordance with this table, whichever -is less.
zSteel deck must be minimum No. 22 gage galvanized steel (base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum
compressive strength (F.) of 2500 psi. See Section 5.6 of this report.
'UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope 1:12) or below
min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
°Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to'/2:12.
SWhen application is over existing roofs, documentation of the wind -uplift resistance of the'composite roof construction must be submitted to
the code official for approval at the time of permit application. For reroofing or recovering, installation must be in accordance with IBC Section
1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to.Chapter 15, as applicable.