Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-0355 (AR)
P.O. BOX1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 6/15/10 Application Number: Z10-`00.000355'. Owner: Property Address: 77182 CALLE FLORA MILLER ROBERT G APN: 658-210-012- - - 1881 SW NAITO PKWY STE 250 Application description: REMODEL - RESIDENTIAL PORTLAND, OR 97201 D p Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 50000 JUN 15 2010 _Contractor.-. _. -_.... _._.._. _ ......._._. _._. _ .:. ". Applicant: Architect or Engineer: GOLDEN CONSTRUCTION NC r 73710 FRED WARING DR STE 1'(�OFLAQUINTA PALM DESERT, CA 9226 INP.NCE DEPT. r 1n (760)776-4215 �J( Lic. No.: 786919 Ole LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busi nd Professionals Cod Amy License is in full force and effect. License Class: B L'� 786919 te:,©�/otractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not.build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: 1 ` I J LQPERnIIT ------------------ WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 719000192 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so become subject to the work rs' compensation laws of California, and agree that, if I sh d be me subject to t/hew compensation provisions of Section 37 of the Labo�Code, I all f h - coxf�pl wi those provisions. ate: pplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS (5100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the asp ,nrmation is rrect. ,I agree to comply with all city and county ordinances and state laws relating to building con ru tion d ere y orize representatives of this coun y to a ter upon the above-mentioned property i p pur ' e . te:�i ture (Applicant or Agent): I LQPERMIT Application Number . . . . . 10-00000355 ------ Structure Information 145SF ADD & RER/VB/RES-3/CLASS-A (ENG] ----- Other struct info . . ---------------------------------------------------------------------------- . . . CODE EDITION 2007/2008 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 414.50 Plan Check Fee 269.43 Issue Date Valuation . . . . 50000 Expiration Date 12/12/10 Qty Unit Charge Per Extension BASE FEE 252.00 — -- - - -. ---------------------------------------------------------------------------- 1:62..50.. ...._...__. Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 46.78 Plan Check Fee 11.70 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/12/10 Qty Unit Charge: Per Extension BASE FEE 15.00 145.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 5.08 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 26.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 11.70 Permit . . . MECHANICAL .Additional desc . Permit Fee 32.50 Plan Check Fee 8.13 Issue Date . . . . Valuation 0 Expiration'Date 12/12/10 Qty Unit Charge Per Extension BASE. FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 2.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 13.00 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 61.50 Plan Check Fee 15.38 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/12/10 Qty Unit Charge Per Extension I LQPERMIT Application Number . . . . . 10-00000355 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 6.00 6.0000 EA PLB FIXTURE 36.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 145SF BATHROOM ADDITION WITH REMODEL TO EXISTING.MASTER BATHROOM/VB/RES-3/CLASS A -FR (ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCKWALLS OR THE RELOCATION OF ----------- ------ - - — EXISTING -MECHANICAL EQUIPMENT.- 2007--- 007-_CALIFORNIA CALIFORNIABUILDING CODES/2008 ENERGY. June 15, 2010 7:49:07. AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . BLDG STDS•ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 26.94 STRONG MOTION (SMI) - RES 5.00 Fee..summary Charged Paid Credited ---------- Due ----------------------------------------------- Permit Fee Total 555.28 .00 .00 555.28 Plan Check Total 304.64 00 .00 304.64 Other Fee Total 33.94 .00 ..00 33.94 Grand Total 893.86 .00 .00 893.86 N LQPERMTf Bin # Qty of La Quinta Building 81' Safety DWon P.O. Box 1504, 78-495 Calle Tampico Permit # La Quinta, CA 92253 - (760) 777-7012 11D Building Permit Application and Tracking Sheet Project Address:7VI2— C -Ole- -Fic re, Owncr'sName: A. P. Number: Address: S 2 G e :- Legal Description: City, ST, Zip: La Un1c, d fivol-L., Contractor: Telephone: . I . . . . . . . . . . . ........... Address: Project Description: a/Jj4 'o ri City, ST, Zip: . . . . . . . . . . . . . . . . . . . . . Telephone: State Lic. #City Lie. _#.- Arch., Engr., Designcr:0-6Ao'— -D eJh XSS c-- ci'c4 f ()R - w Address: 7-3 - 626 Hw I I I City, ST, _Zip.-aLr P lm Qas�± CA q2 2- 6 0 Tele phone(-7� o Construction Type: Occupancy: 3 State Lic. 4: (f -2- 9 Yo Project type (circle one): New (Addn _) 'Alter Repair Demo Name of Contact Person: A re A/ ci, c eu— Sq. Ft.: # Stories:# Units: Telephone # of Contact Person : Estimated Value of Project:T 9 D 4 'Rea -7 D M93PLICANT: DO NOT WRITE BELOW THIS LINE # 'Submittal ReqId Rec!d TRACKING PERMIT FEES Plan Sets 11---, Plan Check submitted item Amount' Structural Calcs. Reviewed, ready for corrections V10 Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance. Title 24 Cala. Plans picked up f d Construction Flood plain plan Plans resubmitted Mechanical Grading plan V Review, readyMetrical 10folf" 0 Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up 6' dle-S.M.I.H.O.A. Approval Plans resubmitted Grading IN HOUSE:- orr ectio issue Review, ready I(r 6b LD Developer Impact Fee Planning Approval _ Called Contact Person I.P.P. Pub. Wks. Appr Date of permit issue School Fecs ToPermit Fees s�►olrh9iK4- --� yrR�ws 4 [Irj[%b W10 S C*M. 5`2� Z0� ' �l�Yhleft Fw Taw 6��'f Q� • �lq #off �l� - sow ov- (M/ CERTIFICATE OF COMPLIANCE 4w�1FIEDS��o Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES O (/1 RANCHO MIRAGE CJ Date 6/3/10 La Quinta, CA 92253 INDIAN WELLS PALMDESERT No. 30714 (760) 771-8515 �� w 1QDIOTA �y 11 10 0 y� Owner Robert & Sharon Miller APN # 658-210-012 Address 77-182 Calle Flora Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # No. of Units Type Residential Addition Lot # No,. Street S.F. Lot # No. Street S.F. Unit 1 77182 Calle Flora 145 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not colied fees on garages/carports, covered patios/Walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 145 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt -Paul Golden Check No. Name on the check Telephone Funding Exempt BY Dr. Sharon P. McGehee Superintendent Fee collected /exempted by Pa icia Barbuzza Payment Recd 4$0.00 L -Over/Under: Signature,, NOTICE: Pursuant to Government Code Secti 020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting ' BUILDING ENERGY ANALYSIS REPORT PROJECT: The Miller Residence - Bath Addition Lots 12 and 13 La Quinta, CA 92210 Project Designer: Ochoa Design Associates 73-626 Highway 111 Palm Desert, CA 92260 760-773-6605 Report Prepared by: Breeze Air Conditioning, Inc. BREEZE AIR CONDITIONING 75-145 St. Charles Place Palm Desert, CA 92211 (760) 346-0855 •0 s.: - CITY OF LA QUINTA**.' BUILDING & SAFETY DEPT APPROVED FOR CONSTRUCTION DAT r BREEZE AIB OONDIIIONING INC Job Number: Date: 4/21/2010 R2ECERVED MAY 2 8 2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has a authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency This program developed by EnergySoft, LLC — www.energysoft.com. t and is -TABLE OF CONTENTS 1 . 4 Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 8 11 12 13 14 EnergyPro 5.0 by EnergySoft Job Number. ID: User Number. 3665 1 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Miller Residence - Bath Addition Building Type m Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1412112010 Date Project Address Lots 12 and 13 La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 145 Addition 145 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 145 Radiant Barrier New Wall Wood Framed R-19 353 New Slab Unheated Slab -on -Grade None 145 Perim = 41' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (N) 3.8 0.320 0.36 none none Bug Screen New Rear (E) 3.8 0.320 0.36 none none Bug Screen New Right (S) 8.0 0.320 0.36 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 8.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Addition Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPrp 5.0 by EnergySoft User Number.- 3665 RunCode: 2010-04-21 T14:17:3 ID: Page 3 of 14 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name The Miller Residence - Bath Addition Building Type ® Single Family ® Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1412112010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Air Conditioner Existing HVAC has an SEER less than the Vintage Defaults. Field verification is required. HIGH MASS Design - Verify Thermal Mass: 122 sgft Concrete, Heavyweight Exterior Mass, 6.000" thick at Bathroom #4 HIGH MASS Design - Verify Thermal Mass: 86 sgft Concrete, Heavyweight Exterior Mass, 6.000" thick at Bathroom #4 HIGH MASS Design - Verify Thermal Mass: 123 sgft Concrete, Heavyweight Exterior Mass, 6.000" thick at Bathroom #4 HIGH MASS Design - Verify Thermal Mass: 23 sgft Concrete, Heavyweight Exterior Mass, 6.000" thick at Bathroom #4 HIGH MASS Design - Verify Thermal Mass: 145.0 W Covered Slab Floor, 3.500" thick at Bathroom #4 The Roof R-38 Roof includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -413 form for each of the measures listed below for final to be given. EnemvPro 5.0 by EnemySoft User Number. 3665 RunCode: 2010-04-21T14:17:3 ID. Page 4 of 14 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family m Addition Alone Date The Miller Residence - Bath Addition ❑ Multi Family ❑ Existing+ Addition/Alteration 1412112010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftz- r Space Heating 16.68 9.52 7.16 Space Cooling 129.51 119.97 9.54 Fans 30.30 27.42 2.88 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 176.48 156.90 19.58 Percent Better Than Standard: 11.1% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 0.03 OAA 23 0 Fuel Available at Site: Natural Gas (N) 126 4 Raised Floor Area: 0 (E) 90 4 Slab on Grade Area: 145 (S) 131 8 Average Ceiling Height: 9.0 Roof 145 0 Fenestration Average U -Factor: 0.32 TOTAL: 16 Average SHGC: 0.36 Fenestration/CFA Ratio: 10.8% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company BREEZE AIR CONDITIONING 75.145 St. Charles Place Breeze Air Conditioning, Inc. 4/11/2010 Address Name g. City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone (760) 346-0855 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Ochoa Design Associates 73-626 Highway 111 Juan Carlos Ocho Address Name City/State/Zip Palm Desert, CA 92260 Phone 760-773-6605 Signed License # ate Ene Pro 5.0 b Ene Soft User Number. 3665 RunCode: 2010-04-21714:17:3 to: Page 5 of 14 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name The Miller Residence - Bath Addition Building Type ® Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/21/2010 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor CaviExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 145 0.025 R-38 270 0 New 4.2.1-A21 Addition Wall 122 0.074 R-19 0 90 New 4.3.1-A5 Addition Wall 86 0.074 R-19 90 90 New 4.3.1-A5 Addition Wall 123 0.074 R-19 180 90 New 4.3.1-A5 Addition Wall 23 0.074 R-19 270 90 New 4.3.1-A5 Addition Slab 145 0.730 None 0 180 New 4.4.7-A1 Addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 3.8 0.320 NFRC 0.36 NFRC 0 New Jeld-Wen Wood Lo/E (Fixed) Addition 2 Window 3.8 0.320 NFRC 0.36 NFRC 90 New Jeld-Wen Wood Lo/E (Fixed) Addition 3 Window 8.0 0.320 NFRC 0.36 NFRC 180 New Jeld-Wen Wood Lo/E (Fixed) Addition (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove anq Left Fin Ri ht Fin Len Hgt LExt REA Dist Len Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 EnergyPlip 5.0 by EnergySoft User Number. 3665 RunCade: 2010-"21T14:17:3 ID: Page 6 of 14 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CFA R Project Name The Miller Residence - Bath Addition Building Type ® Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1412112010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina I Altered Removed Volume Year Built HVAC Addition Bathroom 94 145 1,305 Totals 1 1451 0 01 0 HVAC SYSTEMS System Name City. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC Addition 1 Central Furnace 78% AFUE Split Air Conditioner 8.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Addition Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E w a` Hot Water Piping Length ff o •6 Q c — System Name Pipe Len th Pipe Diameter Insul. Thick. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPro 5.0 by EnemySoff User Number. 3665 RunCode: 2010-04-21T14:17:3 ID: Page 7 of 14 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name The Miller Residence - Bath Addition Date 1412112010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. §150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1506)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnefgyPro 5.0 by EnefgySoR User Number. 3665 RunCode. 2010-04-21T14:17:38 ID: Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date The Miller Residence - Bath Addition 1412112010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porousinner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping,filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.0 by EnergySolt User Number. 3665 RunCode: 2010-0421714:17:38 ID: Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date The Miller Residence - Bath Addition 1412112010 §150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.0 by Energysoft User Number. 3665 RunCode: 2010-04-21714:17:38 ID: Page 10 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Miller Residence - Bath Addition Date 4/21/2010 System Name - . HVAC Addition Rom Area 145 ENGINEERING'CHECKS SYSTEM LOAD Number of T 1 COIL CFM Total Room Loads 207 Retum Vended Lighting Retum Air Ducts Return Fan Ventuatian 200 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK Sensible 3,713 0 356 0 8,478 0 356 1 12,904 COIL HTG. Latent CFM W1 152 4,075 200 4,659 PEAK Heating Sensible Ouw per ty4ern 60.E 4,025 Totat.0 60.E p ut � 413.8 350 Coo 0 OUw per em 56.0001 11,459 Total O , iut , h 56.000 0 Tota! ons 4.7 350 Total O 386.2 Tom 0n 31.1 1 16,185 Air System CFA 2.000 HVAC EQUIPMENT SELECTION Airflaw dm • 2,000 EbsrmV HVAC Tom Adjusted Sygten, Output (Adiusted for Peak Design cantations) I TIME OF SYSTEM PEAK 41.870 .. 41,870 r 5,995 60,000 5,995 1 60,000 3 PM Jan 1 AM Airflow cfml 13.79 Airflow cpgon 428.6 Outside Air 10.0% Outside Air dm/ 1.38 Nota. values above ghren at AFN condition HEATING SYSTEM PSYCHROMETFt1CS Airstremn Temperatures at Time of Heating Fmk 26 OF 74 IF Outside Air 200 dm Supply Fan 2,000 dm 80 OF 74 OF 105 OF Heating Cod 105 OF 'ROOM 80 OF I COOLING SYSTEM PSYCHROMETICS Airstream Tempmamm at Time of CooffM Peak 112/78°F 76/63°F 76/63°F 55/54°F Outside Air 200 dm Supply Fan Cooling Coil 2,000 cirn 72 / 60 OF A 4I 51.5% 55 / 54 °F ! ROOM 72 160 OF EnergyPro 5.0 by Enwl;ySoft User Ahrmber. 3665 RunCade: 201044-21714.,17:38 ID: Page 11 of 14 ROOM LOAD SUMMARY Project Name Date The Miller Residence - Bath Addition 4/21/2010 System Name Floor Area HVAC Addition 145 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name Mult. I CFM Sensible I Latent CFM I Sensible I Latent CFM I Sensible Addition I Bathroom#4 1 1 2071 3,7131 584 2071 3,7131 5841 1521 4,025 PAGE TOTAL TOTAL• 207 3,713 584 152 4,025 207 3,713 584 152 4,025 ' Total includes ventilation load for zonal systems. EnemyPro 5.0 by EnemySoft User Number. 3665 RunCode: 2010.0421714:17:3 ID: Pae 12 of 14 ROOM HEATING PEAK LOADS Project Name The Miller Residence - Bath Addition Date 4/21/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Bathroom #4 Floor Area 145.0 W Indoor Dry Bulb Temperature 80 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT OF R-38 Roof 145.0 X 0.0250 X 54 R-19 Wall 353.4 X 0.0740 X 54 Jeld-Wen Wood Lo/E (Fixed) 15.6 X 0.3200 X 54 Slab -On -Grade perim = 41.0 X . 0.7300 X 54 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total Infiltration:[ 1.00 X 1.064 X 145 X 9.00 X 0.425 /60] X Schedule Air Sensible Area Ceiling Height ACH AT Fraction = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 196 1,412 270 1,616 3,494 = 532 TOTAL HOURLY HEAT LOSS FOR ROOM 4,025 EnergyPro 5.0 by EnefgySoft User Number. 3665 RunCode: 2010.04-21T14:17:3 ID: Pae 13 of 14 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date The Miller Residence - Bath Addition 1 4/2112010 ROOM INFORMATION DESIGN CONDITIONS Room Name Bathroom #4 Outdoor Dry Bulb Temperature 112 OF Floor Area 145.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 72 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof (IM 145.0 X 0.0250 X 56.0 = 203 R-19 Wall (N) 122.2 X 0.0740 X 23.0 = 208 R-19 Wall (E) 86.2 X 0.0740 X 33.0 = 211 R-19 Wall (S) 122.5 X 0.0740 X 26.0 = 236 R-19 Wall W 22.5 X 0.0740 X 33.0 = 55 X X = X X = X X = X X = Page Total 912 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr FxdWdw (B) (N) 0.0 X 19.8 + 3.8 X 19.8 = 75 FxdWdw (B) (E) 0.0 X 19.8 + 3.8 X 41.1 = 156 FxdWdw (A) (S) 0.0 X 19.8 + 8.0 X 19.8 = 159 X + X - X + X - X + X - X + X - X + X - X + X - Page Total 390 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. = d6O Equipment 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.92 X 8.98 X = 351 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,713 Latent Gain Btu/hr Occupants Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 0.92 X 8.98 X 0.00467 = 184 Air Sensible CFM ELA 4W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 584 EnemyPro, 5.0 by EnemySoft User Number. 3665 RunCode: 2010-04-21714:17:3 ID: Pae 14 of 14