10105 (AR)s
Building
Address
William P. Lyon III
P.O. BOX 1504/� N o . 10105
78-3150 Calle Fortuna 78-105 CALLE ESTADO � �{
LA QUINTA CALIFORNIA 9225 y
�4
Marlin 9 BUILDING: TYPE CONFft. OCC: GRP.
Address same. A.P. Number 769-104-002
City Zip ]Tel-
LaQuinta
l 92253 1.
Address,. -, t ,
City i /.� Zlp
State Lic. 7 _. City
f
& CIassif. % J 4.1 1 Lic. # 0
Arch., Engr.,
Designer
Address Tel.
City IZip State
Lic. #
LICENSED CONTRACTOR'S DECLARATION
eby affirm that I am licensed under provisions Qf Chapter 9 (commencing with Section
of Di)Cision 3.of tjte Businessand Professions Oode, and my license is in full force and
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement. that he is licensed pursuant to .
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section -7000) of
Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
O I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I as owner of the property, am exclusively contracting with licensed contractors to con-
truct t
he project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property • who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. - B. & P.C. for this reason
Date Owner
0
i
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of'consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
c CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be complied i/ the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any ma ner sous to become subject to the Wo ers' Compensation
Laws of California.`
Date Owner j /\
NOTICE TO APPLICANT: 1/rafter( making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of" the Labor Code, you must forthwith
comply with such provisions br this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
Legal Description
fi
Project Description Expand existina kitchen &
REMARKS
ZONE: BY:
Minimum Setback Distances:.
Front Setback from. Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
Sq. Ft. 399
Size
No. No. Dw.
Stories Units
New ❑ Add ❑
Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
2iD. �atD
PERMIT
AMOUNT
Plan Clik. Dep.
Plan Chk. Bal.
140.40
Const.
216,.00
Mech.
11.00
Electrical .• '
18.00
Plumbing
24.00
S.M.I.
2.10
Grading
Driveway Enc.
Infrastructure
TOTAL
411.50
REMARKS
ZONE: BY:
Minimum Setback Distances:.
Front Setback from. Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
IST FL. SQ. FT. ® $
UNITS
COLL. AREA
2ND FL S0. FT.
0V
YARD SPKLR SYSTEM
POR. SQ. FT. ®
MOBILEHOME SVC.
BAR SINK
GAR. SQ. FT. ®
POWER OUTLET
ROOF DRAINS
CARP. SQ. FT.
DUCT WORK
DRAINAGE PIPING
WALL SQ. FT.
DRINKING FOUNTAIN
SQ FT ®
HEATING (FINAL)
URINAL
ESTIMATED CONSTRUCTION VALUATION $
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASH ER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
GRADING
cu. yd.
$ plus x$
LAUNDRYTRAY
AIR HANDLING UNIT CFM
FINAL INSP./2 3 Q
� C
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. a c
BATH TUB
SQ. FT. a c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. FESID ® 11/4 c
SEWAGE DISPOSAL
SQ.FT.GAR ® Vbc
HOUSE SEWER
SPARK ARRESTOR
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEEPL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING ? t 44
dgUNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
0V
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH) 2 /
1
METER LOOP
HEATING (FINAL)
OTHER APP.IEQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
FINAL INSP./2 3 Q
� C
FRAMING1,111 Ito
FINAL INSVevVoi /
ROOFING 111,7111
/0� /! /�/ ��
e A0
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING R/ 4�0
MESH
INSULATION/SOUND t /
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS
GARDEN WALL FINAL
TITLE 24 REPORT FOR:
CODY & BRADY - ROOM ADDITION
78150 CALLE FORTUNA
LA QUINTA, CALIFORNIA
PROJECT DESIGNER:
OWNER:
REPORT PREPARED BY:
JOHN H HACKER AND ASSOCIATES
4501 E SUNNY DUNES ROAD SUITE D
PALM SPRINGS CA 92264
619 327-4565 CA LICENSE RCE 14614
r
Job Number:
Date: 9/30/1991
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. This program has interim approval
and is authorized by the California Energy Commission for use with the
Second Generation Nonresidential Building Energy Efficiency Standards
for Nonresidential Occupancies. Second Generation Residential Occupancies
shown to comply with this program conform to the results produced by the
Public Domain Point System, developed by the California Energy Commission.
This program developed by Gabel Dodd Associates (415) 428-0803.
Table Of Contents for Title 24 Report
-------------------------------------
Cover Page .......................................................... 1
Table of Contents ................................................... 2
Form
CF -1R
Certificate of Compliance: Residential ...................
3
Form
MF -1R
Mandatory Measures Checklist: Residential ................
6
Form
P -2R
Point System Summary ......................................
8
Form
WS -4
HVAC System Summary Sheets ................................
9
Form
CF -4
HVAC Summary ..............................................
10
Form
WS -1R
Points Thermal Mass Worksheet ............................
11
Domestic Hot Water Worksheet ........................................ 12
Form WS -5A Lighting Controls Credit Worksheet ....................... 13
CERTIFICATE OF COMPLIANCE: Residential (part 1 of 3) CF -IR page 3 of 15
---------------------------------------------------------------------------
Pro.ject: CODY & BRADY - ROOM ADDITION ; COMPLY 24 v 3.10
--------------------
Designer: ; Building Permit No
' ------------------
Location: Palm Desert Date: 9/30/1991 ; Checked By
------------------
Documentati� Win: JOHN H HACKER AND ASSOCIATES ; Date (User#2655)
----------------------------------------------------------------------------
PROJECT ADDRESS Job Q.
78150 CALLE FORTUNA
LA OUINTA, CALIFORNIA
GENERAL INFORMATION
Area
----
Compliance Method:
Point System
Climate Zane:
15
Total Conditioned Floor Area:
3.30 <sgft
Building Occupancy:
Single Fam Det
Front Entry Orientation:
South
Number of Dwelling Units:
1
Floor Construction Type:
Slab
Infiltration Control:
Standard
BUILDING SHELL INSULATION
Component
---------
Area
----
U -Value Location/Comments
-------
R-19 Frame Wall
268
-----------•-------------------------
0.0655 WHOLE
HOUSE
R-11 Frame Wall
330
0.0973 WHOLE
HOUSE
R-38 Roof/Gyp Ceiling
399
0.0287 WHOLE
HOUSE
Exposed Slab
318
0,9000 WHOLE
HOUSE /Insul= R-0.0
Carpeted Slab
81
007300 WHOLE
HOUSE /Insul = R-0.0
THERMAL MASS
Thick:
Mass Material
Area
(in) Type
Location/Description
---------•------------
Concrete, Heavyweight
----
318
----- -------
4e000 Exposed
------------------------------
WHOLE HOUSE /Int Mass
Concrete, Heavyweight
81
4°000 Covered
WHOLE HOUSE /Int Mass
CERTIFICATE OF COMPLIANCE: Residential (part of 3) CF -1R page 4 Qf 15
Project: CODY & BRADY - ROOM ADDITION COMPLY 24 v 3.10
-
Designer: Building Permit No
________
Location: Palm Desert Date: 9/30/1991 1 Checked By
Documentation: gin: JOHN H HACKER AND ASSOCIATES 1 Date ~
(User# 655)
---------------------------------------------------------------------------
GLAZING Glass w/Int
Location Orient Area Type U -Val SC Shade 'Description
--------- ------ ----- ------ ----- ----- ----- ------•----- - -----------
WHOLE HOUSE
North 34.0 Double 0.65 0.88 0.33 Double/Light Blinds
South 6.0 Double 0.65 0.88 0.33 • Double/Light Blinds
West -34.0 Double 0.65 0.88 0.33 Double/Light Blinds
SHADING (for Glazing above) Over
Location Exterior Device SC hang Framing Type
WHOLE HOUSE
50 % Bug Screen 0.84 2;0 Metal w/o Mullions
50 % Bug Screen 0.84 6.0 Metal w/o Mullions
50 % Bug Screen 0.84 2.0 Metal w/o Mullions
CERTIFICATE OF COMPLIANCE: Residential (part 3 of 3) CF -1R page 5 of 15
---------------------------------------------------0-----------------------
Project: CODY & BRADY - ROOM ADDITION 1 COMPLY 24 v 3.10
| _________________-
Designer: Building Permit No
� __________________
Location: Palm Desert Date: 9/30/1991 | Checked By
� __________________
Documentation: JOHN H HACKER AND ASSOCIATES Date (User # 2655)
---------------------------------------------------------------------------
HVAC SYSTEMS Minimum Output Duct Duct Manufacturer/Model No.
System Type Efficiency (Btuh) Location RVal (or approved equal)
----------- ---------- ------ ---------------- ---- -----------------------
Gas Fired 0.728 SE 31000 Vent. Attic Space 5.2 Day&Night 580AN018040
Air Cond 9.500 SEER 17800 Vent. Attic Space Day&Night 580AN018040
Max. Furnace Output: 45000 Btuh + [(73% - 71%) x 70001 = 57600 Btuh
Cooling Exception: ______ CFM Cooling (see Load Calcs) requires ______ Btuh
HOT WATER SYSTEMS Tank Manufacturer/Model No. # of Energy R-12
System Type Volume (or approved equal) Sys Credits Blanket
------------------- ------ ----------------------- ----- ------- -------
8as Fired 50.0 Std Gas 50 gal or less 1 0 Y
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title 24, Chapter 2-53 and Title 20,
Chapter 2, Subchapter 4, Article 1 of the California Administrative Code.
This certificate has been signed by the individual with overall design
responsibility and the building owner, who shall retain a copy of it and
transmit the certificate to any subsequent purchaser of the building. When
this Certificate of Compliance is submitted for a single building plan to
be built in multiple orientations, all building conservation features which
vary are indicated in the Special Features/Remarks section.
DESIGNER
Lice No. -
Signed:
Signe ---- d�
DOCUMEON AUTHOR
JOHN H HACKER AND ASSOCIATES
4501 E SUNNY DUNES ROAD SUITE D
PALM SPRINGS CA 92264
619 327-4565 CA LICENSE RCE 14614
'
Signed:_
0 " (Date)
BUILDING OWNER
Signed:___________________________
(Date)
ENFORCEMENT AGENCY
Name:_____________________________
Agency:___________________________
Telephone:________________________
Signed:___________________________
(Date)
MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1R page 6 of 15
-----------------------------------------------------------------------
Project: CODY & BRADY - ROOM ADDITION | COMPLY 24 v 3.10
| __________________
Designer: | Building Permit No
: -------------------
Location:
_________________Location: Palm Desert Date: 9/30/1991 | Checked By
� __________________
Documentation: JOHN H HACKER AND ASSOCIATES | Date (User # 2655)
---------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. Items marked
with an asterisk (*) may be superseded by more stringent compliance
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding minimum component performance
5pecifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
Enforcement
o Sec. 2-53520): Minimum ceiling insulation R-19
weighted average. * -----------
o Sec. 2-5352(b): Loose fill insulation manufacturers
labeled R -Value.
o Sec. 2-5352(c): Minimum wall insulation in framed walls R-11
weighted average (does not apply to exterior mass walls). * -----------
o Sec. 2-5352(k): Slab edge insulation - water absorption rate
no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch. ------------
o Sec. 2-5311: Insulation specified or installed meets
California Energy Commission (CEC) quality standards.
Indicate type and form. -----------
• Sec. 2-5352(f): Vapor barriers mandatory in Climate Zones 14
and 16 only. -----------
• Sec. 2-5317: Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Doors and windows certified.
c. Doors and windows weatherstripped; all joints and
penetrations caulked and sealed. -----------
o Sec. 2-5352(e): Special infiltration barrier installed to
comply with Sec. 2-5351 meets CEC quality standards. -----------
o Sec. 2-5352(d): Installation of Fireplaces
1. Masonry and factory -built fireplaces have:
a. Tight fitting, closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST (part z of 2) MF -IR page 7 of 15
---�------------------------------------------------------------------------
Pro ject: CODY & BRADY - ROOM ADDITION 1 COMPLY 24 v 3.10
Designer: 1 Building Permit No
' ------------------
Location: Palm Desert Date: 9/30/1991 1 Checked By
------------------
Documentation: JOHN H HACKER AND ASSOCIATES 1 Date(User# 2655
---------------------------------------------------------------------------
HVAC AND PLUMBING SYSTEM MEASURES
Enforcement
o Sec. 2-5352(g) and 2-5303: Space conditioning equipment
sizing: attach calculations.
o Sec. 2-5.352(h) and -5315: Setback: thermostat on all
applicable heating systems.
o Sec. 5316(a): Ducts constructed, installed and insulated
per Chapter 10, 1976 UMC. * -----------
o
----------o
Sec. 5316(b): Exhaust systems have damper controls.
o Sec. 5314(c): Gas-fired space heating equipment has
intermittent ignition devices.
c i Sec. 2-5314: HVAC equipment, water heaters, showerheads and
faucets certified by the CEC.----_------
o Sec. 2-5352(i): Water heater insulation blanket (R-12 or
greater) for storage & backup tanks for solar water heating
systems; first 5 feet of pipes closest to tank insulated
(R-3 or greater).
o Sec. 5312(E ception I): Pipe insulation on steam and steam
condensate return & recirculating piping. --_--------
o Sec. 2-5318(d): Swimming Pool Heating
1. System has:
a. On/off switch on heater.
b. Weatherproof instruction plate on heater.
c. Plumbed t� � allow for solar.
2. 75 percent thermal efficiency.
3. Pool cover.
4. Time clock.
5. Directional water inlet.
LIGHTING AND APPLIANCE MEASURES
o Sec. 2-5352(j): Lighting - 25 lumens/watt or greater for
general lighting in kitchens and bathrooms. -------.-__-
c; Sec. 2-5314(c): Gas fired appliances equipped with
intermittent ignition devices.
o Sec. 5314(a): Refrigerators, refrigerator -freezers,
freezers and fluorescent lamp ballasts certified by the CEC.
Indicate make and model number.
POINTS SYSTEM
SUMMARY: CLIMATE ZONE 15
P -2R page
8 of 15
---------------------------------------------------------------------------
Project: CODY
& BRADY -. ROOM ADDITION
1 COMPLY 24
v 3.10
Designer:
| Building Permit No
Location: Palm
Desert Date:
i__________________
9/30/1991 | Checked By
|
CARD
Oocumentation:
---------------------------------------------------------------------------
JOHN H HACKER AND ASSOCIATES
__________________
| Date (User
# 2655)
BUILDING DATA
Conditioned
Floor Area 399
sqft
Number of Stories
1
Occupancy
Type
Single Fam
Det
SCORE
-------------------------
CARD
Measure
-------
Points
1.
Roof Insulation
0.0287
(U -Value)
------
1
2.
Wall Insulation
0.0833
(U -Value)
-4
3.
Raised Floor Insulation
`
0.0000
(U -Value)
_
�
3a.
Controlled Vent Crawlspace
0.0
(R -Value)
|
-2
4.
Slab Edge Insulation
0.8633
(f2 factor)-!
|
'
5.
Infiltration
Standard
0
6.
Glass HeatLoss
0.65
18.5%
-3
Sum 1-6 -8
7.
Shade Open Area
-----
% Glass
Sc
OH
Eff %
a.
North 34.0
-------
8.5 x
----
0.74
----
=
-----
6.3
-2
b.
East 0.0
0.0 x
0.00
x 0.00 =
0.0
0
c.
South 6.0
1.5 x
0.74
x 0.47 =
0.5
0
d.
West 34.0
8.5 x
0.74
x 0.85 =
5.4
1
e.
Skylight 0.0
0.0 x
0.00
=
0.0
0
B.
Shade Closed Area
-----
% Glass
-------
Sc
----
OH
Eff %
-----
a.
North 34.0
8.5 x
0.28
----
=
2.4
0
b.
East 0.0
0.0 x
0.00
x 0.00 =
0.0
4
c.
South 6.0
1.5 x
0.28
x 0.44 =
0.2
5
d.
West 34.0
8.5 x
0.28
x 0.78 =
1.9
-2
e.
Skylight 0.0
0.0 x
0.00
=
0.0
0
9.
Interior Thermal Mass
4.12
3
10.
Exterior Wall Mass
0.00
0
Sum 7-10 9
11.
Heating System
0.728 SE
x 0.83
Duct Eff =
0.60
Eff
SE 1
Zonal Control: No
12.
Cooling System
9.500 SEER
x 0.82
Duct Eff =
7.79
Eff
SEER 8
13.
Water Heating (see
DHW Worksheet)
= 0
Point
Total:
---
10
HVAC SYSTEM SUMMARY SHEET WS -4 page 9 of 15
--- A -----------------------------------------------------------------------
Project: CODY & BRADY - ROOM ADDITION 1 COMPLY 24 v 3.10
( __________________
Designer: | Building Permit No
| __________________
Location: Palm Desert Date: 9/30/1991 | Checked By
| __________________
Documentation: JOHN H HACKER AND ASSOCIATES | Date (User # 2655)
---------------------------------------------------------------------------
HEATING
-------
Heating System Name:
System Type:
Output Capacity:
Rated SSE or COP:
Supply Air Temperature:
COOLING
Cooling System Name.-
System
ame:System Type:
Total Output Capacity:
Sensible Output Capacity:
Latent Output Capacity:
Rated EER:
Coil Bypass Factor:
Economizer:
Supply Air Temperature:
FANS
-------
Supply Air CFM:
Fan Type:
Fan Multiplier:
Brake Horsepower:
Motor Efficiency:
Drive Efficiency:
DUCTS
-------
Supply Duct Heat Gain:
Return Duct Heat Gain:
Supply Duct Air Leakage:
Return Duct Air Leakage:
~
Day&Night 580AN018040
Gas Fired
31000 Btu/hr
0.806
105 F
Day&Night 580AN018040
Air Conditioner
17800 Btu/hr
12900 Btu/hr
4900 Btu/hr
8.500
0.100
No
'
55 F
600 cfm
Blow -Through
1
0.33
66.0 %
100.0 %
5.0 %
1.0 %
2.0 %
2.0 %
HVAC EQUIPMENT SUMMARY FORM CF -4 page 10 of 15
.
---------------------------------------------------------------------------
Project: CODY & BRADY - ROOM ADDITION | COMPLY 24 v 3.10
| _________________-
Designer: | Building Permit No
| __________________
Location: Palm Desert Date: 9/30/1991 Checked By
| __________________
Documentation: JOHN H HACKER AND ASSOCIATES 1 Date (User # 2655)
---------------------------------------------------------------------------
HVAC EQUIPMENT SUMMARY BY ZONE
No. Heating Cooling
No HVAC Zone HVAC System (WS -4) Sys KBtu Eff KBtu Eff
-- ----------------------- ---------------------- --- ---- ---- ---- ----
---- ----
' Totals 0 KBtu 0 KBtu
FAN ENERGY
HVAC System
-----------------------
FAN WATTAGE INDEX
No. Motor Drive Conv No. Fan
Sys BHP Eff. Eff. Fact Fans Watts
--- ---- ----- ----- ---- ---- -----
Total 0
0
0 watts / 0 sqft = 0.000 watts/sqft
THERMAL MASS WORKSHEET WS -IR page 11 of 15
Project: CODY & BRADY - ROOM ADDITION COMPLY 24 v 0.10
l -
Designer: 1 Building PermitNo
------------------
Location: Palm Desert Date: 9/30/ 1991 � Checked By
------------------
Documentation: JOHN H HACKER AND ASSOCIATES Date (User # 2655)
------------------------------------------------------------------------------
INTERIOR THERMAL MASS
Mass Material Thick
---------------------- -----
Concrete, Heavyweight 4.00
Concrete, Heavyweight 4.00
INTERIOR MASS FACTOR
Interior Interior
Sides Wall
Mass
Mass
Mass
Exposed U -Value
------- -------
Area
------
Factor
--------
Capacity
--------
1
318.0
X 4.7 =
1494.6
0
81.0
X 1.8 =
147.4
TOTAL
16-4-2.0
1642.0 IMC /
O99 sgft
= 4.12
# Mass listed above with a Wall U -Value denotes the Interior Mass credit.
for Exterior Mass Walls, and are repeated below for Exterior Mass credit.
0 Sides Exposed indicates mass covered with surface material >= R-2.
EXTERIOR MASS WALLS Exterior Exterior
Sides Wall Mass Mass Mass
Mass Material Thick: Exposed U -Value Area Factor Capacity
NONE
DHW WORKSHEET ONE: STORAGE TYPE GAS OR ELECTRIC page 12 of 15
.
---------------------------------------------------------------------------
Project: CODY & BRADY - ROOM ADDITION | COMPLY 24 v 3.10
| ------- ___________
Designer: | Building Permit No
: __________________
Location: Palm Desert Date: 9/30/1991 \ Checked By
| __________________
Documentation: JOHN H HACKER AND ASSOCIATES | Date (User # 2655)
�
---------------------------------------------------------------------------
A EQUIPMENT DATA
1
Water heater type
SG
Enter SG or SE
2
Manufacturer &
18700
KBtu/yr/unit, see Table 1
3
Model number
140
Std Gas 50 gal or less
4
Ignition device
GP
GP, gas pilot or IID, int. ignition device
5
Tank volume
50.0
Total gallons, from CEC Appliance Directory
6
Recovery efficiency
76.0
Percent from CEC Appliance Directory
7
Standby loss
3.1
Percent/hour, from CEC Appliance Directory
8
Rated input
55000
Btu/hr, from CEC Appliance Directory
9
Number of pumps
0
(1 kWh = 3413 Btu)
9
Number of Heaters
1
From building plans (total)
10
Insulation Jacket
Y
(Y/N) R-12 insulating jacket on the plans
B OPERATING DATA
1
Climate Zone
15
See Appendix D
2
Water heating budget
18700
KBtu/yr/unit, see Table 1
3
Tank set temp.
140
F, fixed input
4
Water main temp.
70.0
F, see Table 1
5
Daily hot water load
50
50 or 35 gallons/unit, see Table 1
6
Ambient air temp.
72.6
F, see Table 1
7
Adj Standby Losses
0.0205
See Table 2 or Appendix B
8
No. dwelling units
1
From building plans (total)
9
Number of pumps
0
From building plans
10
Pumping energy
0.0
Watt-hr/yr per Pump, see Table 3
C
WATER HEATING ENERGY
CREDITS
---------------------------------------------------------------------------
1
Credit name
See Table 5
2
Annual savings
0.0
KBtu/yr/dwelling unit, see Table 5
D CALCULATE ANNUAL WATER HEATING ENERGY (KBtu/yr)
1 Recovery
load
10539.4
{[B5
x 8.25
x(140-B4)x
365 x
0.001]-C2}x B8
2 Recovery.energy
13867.6
D1 /
A6
3 Standby
loss energy
4839.6
124
- [(D2 x
1000)/(A8
x A9
x 365)31 x 8.25
x A5
x B7 x
365 x (140-B6) x
0.001 x A9
4 Pumping
energy
0.0
B9 x
B10 x 3.413 x 3 x
0.001
ELECTRIC: {[(D2 + D3) x 33 + D41 / B8
6 Water heating budget
comparison -7.2 KBtu/yr/unit B2 - D5
7 Water heating budget -0.0 Points (D6 / Floor Area) x 2 x B8
HVAC ZONE HEATING & COOLING LOAD SUMMARY page 13 of 15
'
^ ---------------------------------------------------------------------------
Project: CODY & BRADY - ROOM ADDITION | COMPLY 24 v 3.10
| __________________
Designer: 1 Building Permit No
| __________________
Location: Palm Desert Date: 9/30/1991 } Checked By
| __________________
Documentation: JOHN H HACKER AND ASSOCIATES | Date (User # 2655)
---------------------------------------------------------------------------
HVAC ZONE DESCRIPTION
HVAC Zone Name:
WHOLE HOUSE
Heating System Name:
Day&Night 580AN018040
Cooling System Name:
Day&Night 580AN018040
System Multiplier:
1
Heating Schedule:
Residential Heating
Cooling Schedule:
Residential Cooling
Fan Schedule: .
Residential Occupancy
Peak Load Method:
COINCIDENT
Relative Humidity:
'
50
%
COOLING
SPACES IN THIS ZONE PEAK
-----------------------
HEATING
PEAK SENSIBLE
LATENT
----
WHOLE HOUSE , (Jan 12am)
-------
11290
-------
---- --------
(Aug 2pm) 7386
--------
------
299
------
TOTAL SPACE LOAD
11290
7386
299
Bypass Ventilation Air ( 0 cfm)
0
( 0 cfm) 0
-0
Supply Duct Conduction
565
369
Supply Duct Leakage'
226
148
6
Supply Fan Heat Gain
-0
0
.
EFFECTIVE SPACE LOAD
-------
12080
--------
7903
------
305
Ventilation ( 0 cfm)
0
( 0 cfm) 0
-0
Return Air Lighting Gain
0
Return Duct Conduction
121
79
Return Duct Leakage
242
158
6
Return Fan Heat Gain
-1273
1273
TOTAL SYSTEM LOAD
-------
11170
--------
9413
------
311
0.8 tons
0.0 tons
SYSTEM PERFORMANCE
31000
12572
3460
AT DESIGN CONDITIONS
1.0 tons
0.3 tons
RESIDENTIAL SPACE HEATING LOAD SUMMARY page 14 of 15
------------------------------------------------------------------------------
Pr� �.ject: CODY & BRADY - ROOM ADDITION ; COMPLY 24 v 3.10
—
Designer: ; Building Permit No
' -------------------
Location: Palm Desert Date: 9/30/1991 ; Checked By
------------------
Documentation: JOHN H HACKER AND ASSOCIATES ; Date (User ## 2655)
------.--------•--------------------------------------------------------------
Space Name: WHOLE HOUSE
Design Indoor Dry Bulb Temperature:
Design Outdoor Winter Dry Bulb Temperature:
Design Temperature Difference:
70 F
32 F
38 F
Conduction
Area
U -Value
TD
Btu/hr
R-19 Frame Wall
268.0
x
0.0655
x
38.0
= 667
R-11 Frame Wall
330.0
x
0.0978
x
38.0
- 1227
Double/Light Blinds
74.0
x
0.6500
x
38.0
= 1828
R-38 Roof/Gyp Ceiling
399.0
x
0.0287
x
38.0
= 435
Exposed Slab
Perim •= 95.0
x
42
- 3943
Carpeted Slab
Perim = 24.3
x
42
= 1008
Infiltration: 1.00 r 0.018 x
399 sgft x 8.o
ft
x 1.00 AC
x
38.0
= 2183
TOTAL HOURLY
HEAT
LOSS FOR
SPACE
11290
SUPPLY AIR QUANTITY
-------------------
Heating: 11290 Btu/hr / E1.10 * (105 F Supply - 65 F TStat)7
257 cfm
RESIDENTIAL SPACE COOLING LOAD SUMMARY page 15 of 15
'
' _--------------------------------------------------------------------------
Project: CODY & BRADY - ROOM ADDITION | COMPLY 24 v 3.10
| __________-_______
Designer: | Building Permit No
| __________________
Location: Palm Desert Date: 9/30/1991 | Checked By
� __________________
Documentation: JOHN H HACKER AND ASSOCIATES 1 Date (User # 2655)
---------------------------------------------------------------------------
Space Name: WHOLE HOUSE
Design Indoor Dry Bulb Temperature:
Design Outdoor Summer Dry Bulb Temperature:
Design Temperature Difference:
78 F
112 F
34 F
Conduction
Area
U -Value
DETD
Btu/hr
-----------------------
R-19 Frame Wall
------
268.0
x
-------
0.0650 x
----
27.6 =
------
481
R-11 Frame Wall
330.0
x
0.0969 x
27.6 =
883
Double/Light Blinds
74.0
x
0.6179 x
34.0 =
1555
R-38 Roof/Gyp Ceiling
399.0
x
0.0282 x
48.0 =
541
Infiltration: 1.00 x 0.018
x 399
sqft x 8.0
ft
x 1.00 AC x
34.0 =
1954
Shaded
Unshaded
Solar Gain
-----------------------
Orient.
---------
Area SGF
---- ---
Area SGF
SC
Btu/hr
Double/Light Blinds
North [
0.0 x 15
+
---- ---
34.0 x 151
----
x 0.28
------
= 142
Double/Light Blinds
South [
6.0 x 15
+
0.0 x 323
x 0.28
= 25
Double/Light Blinds
West [
12.8 x 15
+
21.3 x 733
x 0.28
= 486
Internal Gain
-----------------------
Op Frac.
--------
Area
Heat
Gain
Conv.
Btu/hr
Lighting
1.00
------
x 399.0
---------
x
0.500 x
-----
3.413 =
------
681
Equipment
1.00
x 399.0
x
0.250 x
3.413 =
340
Occupants
1.00
x 399.0
x
225 /
300 =
299
TOTAL HOURLY
SENSIBLE HEAT
GAIN FOR SPACE
------
7386
Latent Gain
Op Frac.
Area
Heat
Gain
Conv.
Btu/hr
-----------------------
Equipment
--------
1.00
------
x 399.0
---------
x
0.000 x
-----
3.413 =
------
0
Occupants
1.00
x 399.0
x
225 /
300 =
299
TOTAL HOURLY
LATENT HEAT
GAIN FOR SPACE
------
299
SUPPLY AIR QUANTITY
-------------------
Cooling: 7386 Btu/hr
/ [1.08 * (
78 F TStat
-
55 F Supply)] = 297
cfm