Loading...
9835 (SFD)4 P.O. BOX 1504 No. 9835 Building78-105 CALLE ESTADO Address 79-440 Fox hien LA QUINTA, CALIFORNIA 92253 Owner Gustafson -Whipple Inc. BUILDING: TYPE CONST. OCC: GRP. - Mailing Address 77570 Springfield Ln ;r3 A.P. Number 769-542-010 City Zip Tel. Pali; Desert 1 92260 350-0233 Legal Description L©L 58 Tract 25429 Painted Cove - Contractor Project Description 5FD Gustaf Son Whi pie 111C. Address City Zip Tel.: State Lic. City & Classif. $ 6,98379 Lic. # 1653 Sq. Ft. 3800 No. No. Dw. Size Stories Units Arch., Engr., " Designer Dick Whipple New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. Pe -mit does net include block walls or sate as above City Zip State pool, Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of,Division 3 o the Business and Professions Code, and my license is in full force /and g teffectf ` SIGNATURE DATE OWNER -BUILDER DECLARATION Estimated ValUBYlOr1 1 hereby affirm that I am exempt from the Contractor's License Law for the following �(��37 20 reason: (Sec. ,7031.5, Business. and Professions Code: Any city or county which requires a F permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to.nle a signed statement that he is licensed pursuant to PERMIT AMOUNT the provisions or the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that, he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant fora permit Plan Chk. Dep. - 250.00 subjects the applicant to a civil penalty of not more than five hundred' dollars.($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation,.wiII Plan Chk. Bal. 829.27 do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const. Professions Code: The Contractor's License Law does not apply to an owner of property who 1329.00 builds or improves thereon and who does such work himself or through his own employees, - Provided that such improvements are not intended or offered for sale. If, however,. the building Mech. 102 0250 or Improvement is sold within one year of completion, the owner -builder will have the burden Electrical 208910of proving that he did not build or Improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing 205.50 struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who contracts for S.M.I. 29.70 such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ I am exempt under Sec. B. ti P.C. for this reason Grading 20.00 Driveway Enc. 20.00 Date owner Infrastructure 6000.00 Arts in Public 491.09 WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) - is {-y�..'4 r}�j 5 ,� ZG�� :1 f:L?�-S ,T.,_p ! li Policy No. Company (� ` tri -sit 1 ';!'{:} i A 1 9235.16 fyl,Copy is filed with the city.. ❑ Certified copy is hereby furnished. TOTAL 9485.16 923.5.16 CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed i1 the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above•. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SO. FT. ® $ UNITS SLAB GRADE 2ND FL. SO. FT. BONDING YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CAR P. SO. FT. GAS (ROUGH) DRAINAGE PIPING WALL SO. FT. OTHER APPJEOUIP. DRINKING FOUNTAIN. SO FT ® TEMP. POLE URINAL ESTIMATED CONSTRUCTION VALUATION $ GROUT WATER PIPING NOTE: Not to be used as property tax valuation FINAL INSP. FLOOR DRAIN MECHANICAL FEES WATER SYSTEM WATER SOFTENER VENT SYSTEM, FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER FINAL INSP. GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE,TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® I Vi c SEWAGE DISPOSAL GAR. FIREWALL SO.FT.GAR ® 3/ic HOUSE SEWER LATHING GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE E UPL.CK.FEE MECH.FE17 ELECT. FEE 1 SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING: FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESlINITIALS GARDEN WALL FINAL CITY OF L UUM 1^ -- °+oDEPARTMENT OF PLANNING & DEVELOPMENT BUILDING DIVISION 564-2246 24-HOUR NOTICE FOR INSPECTIONS Owner Gustafson -Whipple Inc. Contractor Same Permit Number 9 8 3 5 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOBADDRESS__ 79140 Fox Run Permit does not include block walls or pool TYPE OF INSPECTION DATE INSP. FOUNDATION 8 SETBACK �c�`% MAIN GROUND SYSTEM GROUND PLUMBING / PRE-GUNITE _ DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED CONCRETE SLAB OOISTS 8 GIRDERS ELECTRICAL GROUND WORK DO NOT POUR CONCRETE UNTIL ALL ABOVE HAS BEEN SIGNED ROUGH ELECTRIC f ROUGH PLUMBING ROUGH GAS 8 GAS TEST HEATING 8 VENT - A/C FIREPLACE UITY OF L4 fl(JfFJT ROOF BOND BEAM O.K. TO WRAP GROUT O 4' O 8' t'IVAifL;t UtrAk- 11A FRAMING 3 INSULATION PRE -ROOF COVER NO WORK UNTIL ABOVE HAS BEEN SIGNED \ DRYWALL INTERIOR EXTERIOR LATH 74 POOL PRE PLASTER POOL FENCE 8 GATE SEWER SEPTIC TANK ELECTRICAL PLUMBING ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING 4.88 DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 8/16/91 No. I10810 Owner Name Type of Permit Gustafson -Whipple Inc. No. 79-140 street Fox Run La Quinta Permit # Log # city La Quinta zip 92253 study Area 117 APN # 769-542-010 I Tract # 125429 Lot # ® Square Footage 13800 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of1.58 X ® or $ 6,004.00 have been paid to D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Gustafson Whipple Telephone Name on the checks,° By James E. Lively Assistant Superintendent, Business Services Fee collected /e=Diana Diana M. Allard Payment Received`' Signature Check No. 1536 Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting BAJA July 3, 1991 City of La Quinta e e 78105 Calle Estado La Quinta, Ca. 92253 Gentlemen: Gustafson & Whipple's plans for Lot 58, Tract 25429 Painted Cove at La Quinta, have been approved by our architectural committee. Very truly yours, CHATEAU ESTATES Joe P. Ministrelli Real Estate Brokers 74 900 Highway 111, Suite 113 Indian Wells, California 92210 Telephone: 619.773.9888 Facsirp ile: 619.340.9779 �r °f �wQurKrw P.O. box 1%4 7t}105 CALLE ESTADO LA OUINTA. CALIFORNIA 92257 Contractor Gustaf son-Whi le, Inc. Owner Gustaf,son-Whipple, Inc. Address 77-970 pringfield Ln Ste J Job Address 79-140 Fox Run Palm Desert, Ca 92260 La Quinta Ca 92253 La Quinta City License No.: 1653 Expires: 12-31-91 Bldg. Permit No.: This form shall be posted on the job with the Building Inspection Card and it shall be the duty of the General Contractor or if Owner -Builder Permit, the owner to see that all sub -contractors sign this card, giving his City of La Quinta Business License Number, Contractors License Number and a current certificate of workman's Compensation Insurance Certificate when he starts the job. Failure to comply may cause Building Inspectors to stop work, or complaints to be filed against such contractors or owners. CITY CONT. SUB -CONTRACTORS NAME LIC. NO. EXPIRES LIC. NO. EXPIRES 1. Grade i Excavate G -W, Inc. 1653 12-31-91 498379 9-30-92 2. Pipelines 3. Cement -Foundations Design West Con. 2018 12-31-91 610083 1-31-93. 4. Cement Walks s Drives Design West Con, 2018 12-31-91 610083 1-31-93 5. Asphalt Paving 6. Framing G -W, Inc. 1653 12=31-91 498379 9-30-92 7. Steel Structural B. Masonry Bob Lujan 1992 12-31-91 396154 11-30-92 9. Plumbing Pride Plumbing 1857 3-31-92 473973 5-31-91 Lathing Rick Collup Plast.1868 12-31-91 527086 3-31-93 L1. Drywall Butch Baker Dry. 1880 3-31-92 529362 4-30-93 L2. Plastering Rick Collup P-lasit_1868 12-31-91 527086 3-31-93 13. HVAC Arctic Air 312 12-31-91 351544 4-30-93 14. Electrical Ci.urmins Electric 1653 12-31-91 447384 10-31-91 15. Roofing Dew Roofing 326 12-31-91 409619 7-31-93 16. Sheet Metal 17. Floors -All Types Pages Tile 568876 5-31-93 L8. Glass - Glazing I.W. Glass 610028 1-31-93 19. Insulation/weatherstrip Southland Insul. 215 12-31-91 445813 9-30-91 20. Sewage Disposal 21. Painting/Decorating Southern Sky Paint 565854 6-30-93 22. Tile pages Tile 568876 5-31-93 23. Cabinets -Installations Dian Cabinets 135 12-31-91 487322 2-21-92 24. Ornamental Metal Gabriel's Wrought 25. Fences/Blockwalls Bob Lujan 1992 12-31-91 396154 11-30-92 26. Landscaping Farris Land. 2027 7-30-92 548707 11-30-92 27.. Others 28. DO NOT REMOVE THIS CARD Before Final Building Inspection Will Be Made This Form Must Be Completed and Filed With Title 24 Calcs and Plans RECORDING REQUESTED BY OFFICIAL SIAL •"' }! ARV _'O MILLER ' 'r( '• ` "� (OTr4i7 I'UCLIC-C1UF(?RYIA ` PI"s;"K il'AL Of' If7 RIVERSIDE COUNIy ' t*11z'. � AND WHEN RECORDED MAIL THIS DEED AND. UNLESS WISE SHOWN BELOW. MAIL TAX STATEMENTS OTHER. TO:NAM[ 'AODR MIt Gustafson & Whipple O77-570 Springfield Lane, Suite J [� csATE Palm Desert, CA 92260 !'q:IrL v W Title Order No. Escrow No. Q 7 SPACE ABOVE THIS LINE FOR RECORDER'S USE f PARTNERSHIP GRAN -E•ED The undersigned declares that the documentary transfer tax is 357.50 ,/. • .... , • • , , • ....and is �g computed on the full value of the interest or property conv ed, or is ❑ computed on the full valueless the value of liens or encumbr nces remaining thereon at the time of sale. The land, tenements or realty is located in ❑ unincorporated area M city of ....La. Quinta....................................and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Chateau Estates a Rigistered Michigan Co— partnership organized under the laws of the State of hereby GRANT(S) to GUSTAFSON b WHIPPLE, a California Corporation the following described real property in the City of La Quinta county of Riverside , state of California: Lots 50 and 58 of Tract 25429 in the City of La Quinta as per map recorded in Book 216, Pages 66 through 71 inclusive of Maps, in the office'of the County Recorder of Riverside County. Dated March 73, 1991 STATE OF CALIFORNIA COUNTY OF Riverside J t S.S. On this the 16th day of April 19.91 before me, the undersigned, a Notary Public in and for said County and State. personally appeared Joe P. Ministrelli , personally known to me or proved to me on the basis of satisfactory evidence to be One of the partners of the partnership that executed the within instrument, and acknowledged to me that such partnership executed the same. Signaturefl V CHATEAU TA S, A Registered Michigan Co—Partnership B Joe P. Ministrelli FOR NOTARY SEAL OR STAMP Assessor's Parcel No ............................................. MAIL TAX STATEMENTS TO PARTY SHOWN ON FOLLOWING LINE; IF NO PARTY SO SHOWN,. MAIL AS DIRECTED ABOVE Name GTC 100 Street Address City & State OFFICIAL SIAL •"' }! ARV _'O MILLER ' 'r( '• ` "� (OTr4i7 I'UCLIC-C1UF(?RYIA �$oYl PI"s;"K il'AL Of' If7 RIVERSIDE COUNIy My Commission Expires Nov, 24, 1992 Assessor's Parcel No ............................................. MAIL TAX STATEMENTS TO PARTY SHOWN ON FOLLOWING LINE; IF NO PARTY SO SHOWN,. MAIL AS DIRECTED ABOVE Name GTC 100 Street Address City & State c—. 149223 _O�FICIttI SF4L p t� .10 I'li�l:_L.Ef i a (irrEi;S,ni ,Ajji,rr i� <! PAY COrnnlls;ion Expires Prov. Z 1992 `: r FOR NOTARY SEAL OR STAMP a3 p r N N STATE OF CALIFORNIA 1 CL -0. a CSM COUNTY OF Riverside I SS. CL ro O O N On this 16th day of —April —in the year 1991 (h '- m before me, the undersigned, a Notary Public in and for said County and U) State, personally appeared joe _ Minis rel l i 4) T personally known >>� > Cco N me. to me (or proved to me on the basis of satisfactory evidence) to be the v Qi (n person whose name i s n subscribed to the within instrument, as the Attorney in fact of Z John A Rol l + i and acknowledged to me that he subscribed the name w Ix a O John A. Boll of thereto as principal F~— a and his own name as Attorney 0 in fact '� Signature x u n y Name (Typed or Printed) Notary Public in and for said County and State 149223 _O�FICIttI SF4L p t� .10 I'li�l:_L.Ef i a (irrEi;S,ni ,Ajji,rr i� <! PAY COrnnlls;ion Expires Prov. Z 1992 `: r FOR NOTARY SEAL OR STAMP a3 p r N N Q CL -0. a CSM Q CL ro O O N '— �O C'1 (h '- 0 0 L 0 W O 4) T Q d >>� > Cco N me. W Q Qi (n New L Cc L T 4Y J a0 LL 149223 _O�FICIttI SF4L p t� .10 I'li�l:_L.Ef i a (irrEi;S,ni ,Ajji,rr i� <! PAY COrnnlls;ion Expires Prov. Z 1992 `: r FOR NOTARY SEAL OR STAMP a3 p r N N C r Q: CD N rn a CSM CO -(Oto j N N ro O O N '— �O C'1 (h '- 0 0 � t'=U U) T Q d >>� > Cco N Z Q C W o r fC Qi (n N T 4Y 'c^ W r a C\ d C\ UN � tAV (#t VT of O'CrItt t jq� Tit�1 IIf '14M (oututd, jluitbtn� rznb �Sdfet�r 34illirm*11n This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 79-140 FOX RUN Use Classification SINGLE FAMILY DWELLING Bldg, Permit No. 9835 Group R3 Type Construction VN Fre Zone Use Zone SR Owner of Building GUSTAFSON—WHIPPLE, INC,_ Address 77570 SPRINGFIELD LN. CEJ City PALM DESERT, CA By;RICHARD KIRKLAND —7;Yyij ��� Dote: JUNE 25, 1992 Building Official POST IN A CONSTICUOUS GLACE COMPUTER METHOD SUMMARY Page 1 'C -2R Project Title.......... GUSTWHIP Date........ 06/25/91 Project Address........ 79140 FOX RUN --------------------- LA QUINTA ; Documentation Author... W J FINNELL ; Building Permit # Company ................ Energy Consulting Group Telephone .............. 800-262-9966 ; Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 15 --------------------- MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM C -2R ; User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ; ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS3 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design ---------- Design ---------- Margin = - = Space Heating.......... 6.02 3.21 ---------- 2.81 = = Space Cooling.......... 42.78 .45.20 -2.42 = = Water Heating.......... 4.85 4.82 0.03 = = Total 53.65 53.23 0.42 = _ *** Building ----------------------------------------------------------------- complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 3852 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade (Package D) Number of Building Zones... 1 Conditioned Volume......... 36902 cf Footprint Area ............. 3852 sf Slab -On -Grade Area......... 3852 sf Glazing Percentage......... 21.2 % of FA Average Ceiling Height..... 9.6 fit Cond- Zone Type itioned ---------------------- HOUSE Residence Yes BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Thermostat (sf) ( cf ) Units Type --------- --------- ----- ------------ 3852 36902 1.00 Setback Vent Special Height Vent Area (ft) (sf') ------ --------- 2 .0 n/a 9 ' Window 71.0 2 Window 212.0 COMPUTER METHOD SUMMARY Page 2 4 !C=2R Project ------------------------------------------------------------------------------- Title.......... GUSTWHIP Date........ 06/25/91 ------------------------------------------------------------------------------- MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM C -2R ; ------------------------------------------------------------------------------- User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ; OPAQUE SURFACES Area --------------- U- Insul Act Solar Location/ Form 3 Surface ------------ (sf) ------ value R-val Azmth ----- ----------- Tilt Gains Comments ---- ----- ---------------- Reference ------------- HOUSE 1 Wall 485 0.065 R-19 270 90 Yes OUTSIDE None 2 Wall 189 0.065 R-19 270 90 No GARAGE None 3 Wall 344 0.065 R-19 0 90 Yes OUTSIDE None 4 Wall 198 0.065 R-19 0 90 No GARAGE None 5 Wall 617 0.065 R-19 90 90 Yes OUTSIDE -None 6 Wall 450 0.065 R-19 180 90 Yes OUTSIDE None j 7 Roof 3852 0.029 R-38 0 0• Yes None 8 Door 48 0.330 R-0 270 90 Yes OUTSIDE None 9 Door 20 0.330 R-0 270 ,90 No GARAGE None PERIMETER LOSSES ---------------- Length F2 Insul I Surface ------------------ (ft) Factor R-val Location/Comments HOUSE --------------- ---------------------- t 10 S1abEdge 40 0.900 R-0 OUTSIDE 11 S1abEdge 9 0.550 R-0 GARAGE 12 S1abEdge 233 0.720 R-0 OUTSIDE' 13 S1abEdge 33 0.500 R-0 GARAGE GLAZING SURFACES ---------------- SC Interior SC Area # of Frame Open ' U- Act Glass Shade GIs+ Surface ----------- (sf) Panes Type Type ----- ------------- ------ value Azmth Tilt Only ----- ----- ---- ----- Type ---------- Shade ----- HOUSE 1 Window 71.0 2 Metal Slider 0.65 270 90 0.77 LGT VENETI 0.29 2 Window 212.0 2 Metal Slider 0.65 0 90 0.77 LGT VENETI 0.29 3 Window 216.0 2 Metal Slider 0.65 90 90 0.77 LGT VENETI 0.29 4 Window 316.0 2 Metal Slider 0.65 180 90 0.77 LGT VENETI 0.29 EXTERIOR SHADING ---------------- Area Shading SC of Surface (sf) Type Ext Shade ------------ ------ ---=----------- --------- HOUSE 1 Window 71.0 2 Window 212.0 3 Window 216.0 4 Window 316.0 50% bug scrn 0.84 j 50% bug scrn 0.84 50% bug scrn 0.84 50% bug scrn 0.84 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... GUSTWHIP Date........ 06/25/91 MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM C -2R ; User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ------------------------------------------------------------------------------- Mass Type --------------- HOUSE 1 S1abOnGrade 2 S1abOnGrade 3 InteriorHorz 4 InteriorVert THERMAL MASS ------------ Area Thick Heat Conduct- Surface (sf) (in) Cap ivity R -value Location/Comments ------ ----- --------------------- -------------------------- 858 3.5 28.0 0.98 R-0.0 KITCHEN/ENTRY/BATHS 2994 3.5 28.0 0.98 R-2.0 REST OF HOUSE 156 1.0 24.0 0.67 R-0.0 tile= kitchen & bathsi 415 4.0 21.0 0.59 R-0.0 3 FIREPLACES HVAC SYSTEMS ------------ Minimum Duct System Type Efficiency Location ---------------- ------------ ------------- HOUSE Gas 0.800 SE Attic AirCond 10.00 SEER Attic WATER HEATING SYSTEMS Duct Duct R -value ------- Efficiency ---------- R-2.1 0.780 R-2.1 0.740 Capa- R-12 or Pilot System # of city Greater Effic- Standby Input Size ! Type ---------- Heat (gal) ---- ----- Blanket iency Loss Rating ------------------ ------ ------------, (Btuh) Credits -------- -------- Storage Gas 2 38 Yes 0.817 RE 2.20 32000 Btuh n/a None SPECIAL FEATURES/REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R ------------------------------------------------------------------------------- Project Title.......... GUSTWHIP Date........ 06/25/91 Project Address........ 79140 FOX RUN ---------------- 7 ---- LA QUINTA Documentation Author... W J FINNELL ; Building Permit # Company ................ Energy Consulting Group Telephone .............. 800-262-9966 ; Plan Check/ Date Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date ; Climate Zone........... 15 --------------------- --------------------------------------------------------------------------=---- ------------------------------------------------------------------------------- MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM CF -1R User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ; -------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 3852 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number.of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) Infiltration Control....... Standard BUILDING SHELL INSULATION Component Insul Type R -value Location/Comments Wall R-19 OUTSIDE, GARAGE Roof R-38 Door R-0 OUTSIDE, GARAGE S1abEdge R-0 OUTSIDE, GARAGE GLAZING Glazing Area # of Interior Exterior Framing Orientation (sf) Panes Shading Shading Overhang Type! ------------------- ------ ----- ---------- -------------- -------- -------- Window Front (W) 71.0 2 LGT VENETI 50% bug scrn None Metal. Window Left (N) 212.0 2 LGT VENETI 50% bug scrn None Metal' Window Back (E) 216.0 2 LGT VENETI 50% bug scrn None Metal: Window Right ( S ) 316.0 2 LGT VENETI 50% bug scrn None Metal!, THERMAL MASS ------------ Area Thickness Hard Surfaced/ Type (sf) (in) Exposed Location/Comments ----------- ----------=------------------- ----------------------- S1abOnGrade 858 3.5 Yes KITCHEN/ENTRY/BATHS SlabOnGrade 2994 3.5 No REST OF HOUSE InteriorHorz 156 .1.0 Yes tile: kitchen & baths InteriorVert 415 4.0 Yes 3 FIREPLACES i CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... GUSTWHIP Date........ 06/25/91 MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM CF -1R ; User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ------------------------------------------------------------------------------- ASSUMED HVAC SYSTEMS Assumed Duct Duct Assumed System Efficiency Location R -value --------------- ------------ ------------- ------- Gas 0.800 SE Attic R-2.1 AirCond 10.00 SEER Attic R-2.1 Actual System --------------- Heating Cooling Cooling Coil ACTUAL HVAC SYSTEMS ------------------- Actual Output Manufacturer and Model # Efficiency ( Stuh ) ( or approved equal) --------------------------------------------------- CEC Maximum output for Gas Central Furnaces: 142021 Btuh WATER HEATING SYSTEMS Tank R-12 or # of Vol Greater Manufacturer and Model # Energy System Type Heat (gal) Blanket (or approved equal) Credits --------------------- ---- ----- ------- ---------------------------- ---------- Storage, Gas 2 38 Yes A 0 SMITH PGS -040 None SPECIAL FEATURES/REMARKS ------------------------ CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R ------------------------------------------------------------------------------- Project Title ........... GUSTWHIP Date........ 06/25/91 MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM CF -1R ; User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it a'nd transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan .to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. Name... Company Address Phone.. License Signed DESIGNER DOCUMENTATION AUTHOR Name.... W J FINNELL Company. Energy Consulting Group Address. 34F Indian Hills Mtn Center, CA 92361 Phone... 800-262-9966 Signed b Z� ( date OWNER Name .... _/tC[,=MRA2 W tfiP.0cf- Company. Address. d 1 - o s c 2Ge� Phone ... Q —UZ / Signed (date),". Name .... Title... Agency.. Phone... Signed ENFORCEMENT AGENCY ( date ) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -IR Project Title.......... GUSTWHIP Date........ 06/25/91 Project Address........ 79140 FOX RUN --------------------- LA QUINTA ' ' Documentation Author... W J FINNELL ; Building Permit # Company. '*'"* ....... "'' ompany................ Energy Consulting Group Telephone .............. 800-262-9966 ; Plan Check / Date Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 15 ________________ ------------------------------------------------------------------------------- MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM MF -1R User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er meet J* 2-5352(a): Minimum ceiling insulation R-19 weighted average. 2-5352(b): Loose fill insulation manufacturers labeled R -Value. I* 2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3e, water vapor transmission rate.no greater than 2.0 perm/inch. 2-5311: Insulation specified or installed meets CEC quality standards. Indicate type and form. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16. 2-5317: Infiltration/Exfiltration•Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CEC quality standards. 2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have:. a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF-iR Project Title ........... GUSTWHIP Date........ 06/25/91 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -FORM MF -1R ; User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ; ------------------------------------------------------------------------------- HVAC AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 2-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. 2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. 2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. 2-5316(b): Exhaust systems have damper controls. 2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 2-5352(i): Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar water heating systems (first 5 feet of pipes closest to tank insulated to R-3 or greater). 2-5312(Exception I): Pipe insulation on steam and steam .condensate return and recirculating piping. 2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. LIGHTING AND APPLIANCE MEASURES Design- Enforce- er ment 2-5352(j): Lighting - 25 lumens/watt-or greater for general lighting in kitchens and bathrooms. ' 2-5314(c): Gas fired appliances equipped with intermittent ignition devices. 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. WATER HEATING Page 1 DHW Project Title.......... GUSTWHIP Date........ 06/25/91 Project Address........ 79140 FOX RUN --------------------- LA QUINTA Documentation Author... W J FINNELL ; Building Permit # Company ............... Energy Consulting Group Telephone .............. 800-262-9966 ; Plan Check / Date Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 15 --------------------- ---------- ----------------------------------------------------------------=---- ------------------------------------------------------------------------------- MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -WATER HEATING User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ; ---------------------------------------------------------------------------`----- WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC A. EQUIPMENT DATA ----------------- 1. Water heater type....... 2. Manufacturer............ 3. Model number............ 4. Ignition device......... 5.'Tank volume ............. 6. Recovery efficiency..... 7. Standby loss............ S. Rated Input ............. 9. Number of Heaters....... 1O.Insulation Jacket....... Storage, Gas A 0 SMITH PGS -040 n/a 38 gal .817 percent x 0.01 .022 percent/hour x 0.01 32000 Btu/hr 2 Yes B. OPERATING DATA ----------------- 1. Climate Zone............ 2. Water heating budget.... 3. Tank set temp........... 4. Water main temp......... 5. Daily hot water load.... 6. Ambient air temp........ 7. Adj. Standby Losses..... 8. No. dwelling units...... 9. Pump power .............. 1O.Pumping energy.......... 15 18700 kBtu/yr/unit 140 F 70 F 50 gal 72.6 F .01562 1 0 Watts (0 Watts controller) 0 Watt-hr/yr (24 hr per day) C. WATER HEATING ENERGY CREDITS ------------------------------- 1. Credit Name ............. None 2. Annual savings.......... 0 kBtu/yr/unit D. ANNUAL WATER HEATING ------------------------------ ENERGY 1. Recovery load........... 10539 kBtu/yr 2. Recovery energy.....:... 12900 kBtu/yr 3. Standby loss energy..... 5649 kBtu/yr 4. Pumping energy.......... O kBtu/yr source 5. Total energy............ 18550 kBtu/yr/unit source 6. Comparison .............. 151 kBtu/yr/unit source 7. Points .................. 0 8. Water Heating Energy Use 4.82 kBtu/yr/sf (D5 x BS) / 3852 sf i HVAC SIZING Page 1 4HVAC Project Title.......... GUSTWHIP Date........ 06/25/91 Project Address........ 79140 FOX RUN --------------------- LA QUINTA Documentation Author... W J FINNELL ; Building Permit # Company ................ Energy Consulting Group Telephone .............. 800-262-9966 ; Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date ; Climate Zone........... 15 --------------------- -- --- --------------------------------------------------------------------- MICROPAS3 v3.11 File-GUSTWHIP Wth-CTZ15 Program -HVAC SIZING User#-MP1325 User -Energy Consulting Group Run-GUSTWHIP ; ----------- =------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 3852 sf Volume ...................'.. 36902 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude........... ...... 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F. Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 30 F Shading Used ............... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts........ ..................... Sensible Load .................... Latent Load ...................... Heating Cooling (Btuh) (Btuh) ---------------------- 20818 11217 21720 18012 n/a 26367 21760 12895 n/a 2550 6430 7104 70727 78145 n/a 15629 Total Load 70727 93774 Note= The loads shown are only one of the criteria"affecting the selection of 'HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. i CEC Maximum output for gas central furnaces only: 1.3 x ( 70727 + (10 x 3852) ) = 142021 Btuh