09-0265 (AC)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
09-00000265
Property Address:
51455 DESERT CLUB DR
APN:
770-153-003- -
Application description:
ADDITION - COMMERCIAL
Property Zoning:
VILLAGE COMMERCIAL
Application valuation:
10000
T-4u4t 4 4 4"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
BOB EDWARDS
51455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS -(760) 777-7153
Date: 5/05/09
Contractor:
Applicant: Architect or Engineer: EDWARDS CONSTRUCTION INC, BOB
51455 DESERT CLUB DRIVE
LA QUINTA, 92253
Y,
(760)777-8202 .
L
V� Lic. No.: 684857
MhY 0 G 2909
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class/: B seNo.: 684857
.Date:p Contractor:
OWNER.BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.:
(_ I 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
I 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
WORKER'S COMPENSATION DEC ATION
I hereby affirm under penalty of perjury one of the following declarations:--�"`-R-'1-`-� PY
i
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier GRANITE STATE Policy Number WC 555-61-55
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
`Date: Applicant:,
WARNING: FAILURE TO SECURE W v1P iQN O RAGE NLAWFUL, AND�L
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to buildi truction, and hereby authorize representatives
of this coj�nt enter on the above-mentioned pr or inspec os
Date. � on
(Applicant or Agent):
Application Number . . . . . 09-00000265
-- --- Structure Information 16OSF ADDITION/VB/B/24-OL/CL-A (ENG] -----
Construction Type . . . . . TYPE V -B
Occupancy Type . . . . . BUSINESS <50
Other struct info . . . CODE EDITION 2007CODES
FIRE SPRINKLERS NO
MIXED-USE OCCUPANCY B
OCCUPANT LOAD 24..00
TOT ELIGIBLE NO
1ST FLOOR SQUARE FOOTAGE 160.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc .
Permit Fee 117.00 Plan Check Fee 76.05
Issue Date . . . . Valuation 10000
Expiration Date 11/01/09
Qty Unit Charge Per Extension
. BASE FEE 45.00
8.00 9.0000 THOU BLDG 2,001-25,000 72.00,
-----------------------------------------------------•-----------------------
Permit
Additional desc .
Permit Fee
Issue Date
Expiration Date .
ELECT.- ADD/ALT/REM
18.20
11/01/09
Plan Check Fee 4.55
Valuation 0
Qty Unit Charge Per Extension
BASE FEE 15.00
160.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 3.20
----------------------------------------------------------------------------
Permit . . MECHANICAL
Additional desc .
Permit Fee . . . . 19.50 Plan Check Fee'. 4.88
Issue Date . . . . Valuation 0
Expiration Date 11/01/09
Qty Unit Charge Per Extension
BASE FEE 15.00
1.00 4..5000 EA MECH VENT INST/ DUCT ALT 4.50
-------------------------------------------------------'---------------------
Special Notes and Comments
160SF ADDITION/VB/B/24-OL/CLASS A -FR
[ENGINEERED] THIS PERMIT DOES NOT
INCLUDE ADDITIONAL MECHANICAL UNITS OR
LQPERMIT
Application Number
. . . . .
09-00000265
----------------------------------------------------------------------------
Special Notes and Commerits
COVERED PATIO AREAS.
2007 CALIFORNIA
BUILDING CODES.
May 5, 2009 4:28:37
PM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . .
. . . .
ACCESSIBILITY
PLAN REVIEW
7.61
BLDG STDS ADMIN
(SB1473)
1.00
ENERGY REVIEW
FEE
7.61
STRONG MOTION
(SMI) - COM
2.10
Fee summary
Charged
Paid
Credited
Due
-----------------
Permit Fee Total
----------
154.70
--------------------
.00
----------
.00
154.70
Plan Check Total
85.48
.00
.00
85.48 .
Other Fee Total
18.32
..00
.00
18.32
Grand Total
258.50
.00
.00
258.50
LQPERMIT
Bin #
a
nC
City �-of La u►nta
Building & Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit # !
LOA�•/
Project Address: 45 S ' �r�,�(�/�
Owner's Name: 50 F! rz;%�VA�
A. P. Number: 7%O (S/ 003; 1.
Address: 71 -455 D; G =_ 45WF
Legal Descriptior>t-v76 . rm. l
City, ST, Zip:
Contractor:
Telephone:
Address:. SS
Project Description:
City, ST, Zip:Lk
'6� P 074
^ r
0 �� ! I .�/ OF
Telephone: O Z
91 4 DCt:
State Lic. # : v 4 �%
City Lic. #: �V Z
/w
61a 0M Me � 'l O
Arch., wcgT . P/=4f MOD
Address: S FOX- US
City, ST, Zipp4tM-
Telephone: -54 6 g, 74
Construction Type: Occupancy:
State Lic. #:
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person:
Sq. Ft.:' O
# Stories: # Units:
Telephone # of Contact Value of Proi
APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal Req'd Ree'd TRWCKIN2� r-, � _ l PERMTC FEES
Plan Sets p� Plan Check submittcJ1 0) Item Amount
Structural Calcs.
Reviewed, ready for co��ectia(�sAR 2 p 2 9 I Plan Check Deposit
NIIII
Truss Calcs.
uu
Called Contact Perso '� l Plan Check Balance
Energy Cales.
Plans picked up y Construction
Flood plain plan
Plans resubmitted D4echanical
Grading plan
2nd Review, ready for cormetio ssu Electrical
Subcontactor List
Called Contact Person Plumbing
Grant Deed
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted Grading
IN HOUSE:-
''d Review, ready for correctionstissue Developer Impact Fee
Planning Approval
Called Contact Per
I.P.P.
Pub. Wks. Appr
Date of permissue
'
School Fees
Total Permit Fees
(ACJ �G Cotuk9 es % � � Vj9
s g --
�k��> q
Date
5/5/09
No.
30380
Owner
Bob Edwards
Address
51455 Desert Club Drive
City
La Quinta Zip
Tract #
Type
Commercial
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
Jurisdiction
Permit #
No. of Units
Lot # No. Street S.F. Lot # No.
Unit 1 51455 Desert Club Drive 160 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
4. �Z21ED&I
�
z ��9�SIR/�^ i o
BERMUDA DUNES t�
N RANCHO MIRAGE ('7
?+ INDIAN WELLS
PALM DESERT ,y
V LA QUINTA
O INDIO y�
770-153-003
La Quinta
1
Street
S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.47 X 160 S.F. or $75.20 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Cash - Ed Randall
Name on the check
x
BY Dr. Sharon P. McGehee
Superintendent
Check No.
Telephone
Funding Commercial
Fee collected /exempted by Sharon McGilvrey Payment Recd
$75.20 --Over/UWdde
} `r
Signature 2CA
NOTICE: Pursuant to Government Code Section 66020(d)(1), this Will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
the -0, fty� lmtwew
STRUCTURAL AND CIVIL ENGINEERING
DENISE R. POELTLER, INC.
73.661 Highway 111 • Suite G 9 Palm Desert, California 92260
27 April 2009
Mr. Tom Hartung, Building Director
CITY OF LA QUINTA
Department of Building and Safety
78-495 Calle Tampico
La Quinta, CA 92253
RE: BOB EDWARDS OFFICE ADDITION
Job Site Address: 51-455 Desert Club Drive
Subject: Truss Acceptance Letter
Dear Mr. Hartung:
I have reviewed the total deflection, live, dead, and drag loads used for the design of the
gang -nail roof trusses prepared by AC HOUSTON (dated 03-25-09), and found them in
substantial conformance with the structural documents prepared by my firm.
Respectfully submitted,
Denise R. Poeltler
R.C.E. 33446
W.O. 09-126
cc: Rob Pitchford
(760) 779-0405 0 FAX (760) 779-1317
� �� APR 2 7 2009
TITLE 24 REPORT
Title 24 Report for:
Bob Edwards Construction -Addition
51-455 Desert Club Drive
La Quinta, Ca 92253
Project Designer:
Robert Pitchford, Architect
74-835 Fox Hill Court
Palm ,Desert, CA 92211
(760) 346-8776
Report Prepared By:
Jon Scott
Scott Design & Title 24
77085 Michigan Dr.
Palm Desert, CA 92211
(760) 200-4780
Job Number:
Date:
4/9/2009
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY AD
AIR 2 7 Zoog �p
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com. .
EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Nonresidential Performance Title 24 Forms
Form ENV -MM Envelope Mandatory Measures
Form LTG -7-C Room Cavity Ratio Worksheet
Form OLTG-1-C Certificate of Compliance
Form OLTG-2-C Lighting Compliance Summary
Form OLTG-3-C Illuminated Area Calculation Worksheet
Form LTG -MM Lighting Mandatory Measures
Lighting Inspection Checklist
I
1
2
3
10
11
12
14
15
16
17
EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712
4
PERFORMANCE CERTIFICATE OF COMPLIANCE Pali 1 of 3 PERF -
PROJECT NAME
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
DATE
Bob Edwards Construction -Addition
DATE OF PLANS
4/9/2009
OJECT ADDRESS
160 Sq.Ft.
St �� � ♦
51-455 Desert Club Drive La Quinta
BUILDING TYPE ®
`" __j
PRINCIPAL DESIGNER - ENVELOPE
TELEPHONE
Building Permit #
Robert Pitchford, Architect
(760) 346-8776
EXISTING + ADDITION/ALTERATION
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date+
Scott Design & Title 24
(760) 200-4780
. Enforcement Agency use
GENERAL INFORMATION
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DATE OF PLANS
SIGNATURE
BUILDING CONDITIONED FLOOR AREA
160 Sq.Ft.
St �� � ♦
CLIMATE ZONE
1 15
BUILDING TYPE ®
NONRESIDENTIAL HIGH RISE RESIDENTIAL
permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116,
HOTELIMOTEL GUEST ROOM
PHASE OF CONSTRUCTION
NEW CONSTRUCTION ADDITION
®
EXISTING + ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DOCUMENTATION
DOCUMENTATION AUTHOR
SIGNATURE
DATE
Jon Scott
St �� � ♦
-f-ti-401
The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is
consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this
permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
❑ r -j ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect.
0 El 2.1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
❑ F-1 F-1 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Regrir'N Fo s a ANV-1
PRINCIPAL ENVELOPE DESIGNER - NAME S NO. D99T
]LIC.
Robert Pitchford Architect CAVS16 9 �
LIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ReMF ms TG -1, LTG -2
PRINCIPAL LIGHTING DESIGNER - NAME S LIC. NO. DAjT
GIZ31$
Robert Pitchford Architect q
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Mechanical Compliance Not In the Scope Of
This Submittal
Required Forms
PRINCIPAL MECHANICAL DESIGNER - NAME
SIGNATURE
LIC. NO. DATE
Run Initiation Time: 04/07/09 14:39:04 Run Code: 1239140344
EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page:3 of 17
[PERFORMANCE-CE-R�-TI'F-ICA'TE'O'-FCOMPLIAN'CE� Pa:rt2 of 3 PERF
PROJECT NAME DATE
Bob- Edwards Construction -Addition 4/9/2009
ANNUAL TDV ENERGY.USE SUMMARY kBtu/s ft- r ..
ENERGY COMPONENT
Standard
Design
1
Proposed Compliance
Design Margin I[j-siandera f•�
0.10 0.13 INNER � �
.242.49 0.53
78.95 2.58 mn
-0.00 0.00
0.00 0.00
38.51 0.00 v
69.66 9.65 �`�'® � �� � � ��� r��k� � �•
n
- -
�R�.
9.1.54
o io. ,ao, soy ao goo izo iao��sosozoo�zzoY2do
521.24 13.18
2.5% ( 2.5% excluding process)
Space Heating
Space Cooling
Indoor Fans
Heat Rejection
Pumps & Misc.
Domestic Hot Water
Lighting
Receptacle
Process
TOTALs:
*Percent better than Standard:
0.23
243.01
81.53
0.00
0.00
38.51
79.61
91.54
Front Elevation N
534.43
sqft.
BUILDING- COMPLIES
GENERAL INFORMATION
Building Orientation
Number of Stories
Number of Systems
Number of Zones
N 0 d eg
Conditioned Floor Area 160 sqft.
Unconditioned Floor Area 0 sqft.
Conditioned Footprint Area 160 sqft.
Fuel Type Natural Gas
1
1
1
Standard Proposed
Lighting Power Density .` 1.200 wisgft. 1.050 wisgft.
Prescriptive Env. Heat Loss 39 Btum 35 Btum
Prescriptive Env. Heat Gain 3,810 Btu/h-F 3,666 Btum-F
Remarks:
Run Initiation Time: 04/07/09 14:39:04 Run .Code: 1239140344
EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page:4 of 17
i
Orientation
Gross Area
Glazing Area
Glazing
Ratio
Front Elevation N
0
sqft.
0
sqft.
0.0%
Left Elevation (E)
0
sgft.
0
sqft.
0.0%
Rear Elevation S
129
sqft.
5
sqft.
4.0%
Right. Elevation (W)
Total
Roof
86
215
16o
sqft.
sgft.
sqft.
20
25
sqft.
sqft.
sqft.
23.4%
11.86/6
0.0%
Standard Proposed
Lighting Power Density .` 1.200 wisgft. 1.050 wisgft.
Prescriptive Env. Heat Loss 39 Btum 35 Btum
Prescriptive Env. Heat Gain 3,810 Btu/h-F 3,666 Btum-F
Remarks:
Run Initiation Time: 04/07/09 14:39:04 Run .Code: 1239140344
EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page:4 of 17
i
"ERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1
ECT NAME
Bob Edwards Construction -Addition
E INFORMATION
DATE
4/9/2009
Floor Inst. :IA ea LPD I C edits Aeawed LPD I I Proc. I Tailored oads I I
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
The exceptional features listed In this performance approach application have specifically been reviewed. Adequate written justification and
cumentation for their use have been provided by the applicant.
Authorized Signature or Stamp
dation Time: U4/U UU 14:JU:U4 Kun Gose: 1ZS914U344
EneravPro 4.4 by EneravSoft User Number: 6712 Job Number: Page:5 of 17
r
L
CERTIFICATE OF COMPLIANCE ENV -1 -C
ECT NAME
Bob Edwards Construction -Addition
DATE .
4/9/2009
N, E, A. R (New, Existing, Altered, Removed)
FENESTRATION SURFACES
FMore than or equal to 10,000 sq.ft, of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from
Standards Table 116-A and S. Certifimte shall he filed in the mntractnes nmiect office dudna construction and in the building manaaefs office after Construction
# Type
Area U -Fac'
SHGC2
Act.
Azm.
Cond.
Stat.
Glazidg Type
Location/
Comments
1 Window Rear S
III W-11 6 181:11 VIM
WkTA:qF4TZTiT-Z
Location Comments
180
New
Glass Block
Addition
2 Window Rear S
3 0.720 NFRC
0.39 NFRC
180
New
Glass Block
Addition
Window Right
20 0.390 NFRC
0.37 NFRC
270
New
Double Non Metal Tinted
Addition
N, E, A. R (New, Existing, Altered, Removed)
FENESTRATION SURFACES
FMore than or equal to 10,000 sq.ft, of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from
Standards Table 116-A and S. Certifimte shall he filed in the mntractnes nmiect office dudna construction and in the building manaaefs office after Construction
# Type
Area U -Fac'
SHGC2
Act.
Azm.
Cond.
Stat.
Glazidg Type
Location/
Comments
1 Window Rear S
3 0.720 NFRC
0.39 NFRC
180
New
Glass Block
Addition
2 Window Rear S
3 0.720 NFRC
0.39 NFRC
180
New
Glass Block
Addition
Window Right
20 0.390 NFRC
0.37 NFRC
270
New
Double Non Metal Tinted
Addition
(1) LI -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value.
2 SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
Window Overhang Left Fin Right Fin
## Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t.
1 None 0.76
2 None 0.76
3 None 0.76
INIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general
lighting of at least 0.6 Wfft2. See Section M(c). If this box Is checked, ENV-" must be filled out. when submitting under the Prescriptive Compliance Approach.
Run Initiation Time,• 04/07/09 14:39:04 Run Code: 1239140344
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:6 of 17
4
CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C
NAME DATE
Bob Edwards Construction -Addition I
4/9/2009
INSTALLED
WATTS
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 168
PORTABLE LIGHTING (From LTG -3-C) 0
LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0
CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 1 168
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0
ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES
❑ COMPLETE BUILDING METHOD (From LTG -5=C) , ALLOWED
❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS
❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 168
ALTERNATE COMPLIANCE
PERFORMANCE METHOD '
COMMMON LIGHTING SYSTEM (From LTG -8-C)
9
ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES: From LTG -5-C) 0
MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS
CONTROL LOCATION
CONTROL
IDENTIFICATION
Ir C.
CONTROLTYPE
Auto Time Switch, Dimm
cm e- aid ar-
N
u:
Check if
SPACE CONTROLLED Daylighting
AC G kvwm
NOTE TO
,FIELD
NOTES TO FIELD - For Building((De artment Use Only
h^EJ4-,.wTj.t..�
g
ly`�SJ I�}Yr �S �^`d��F.ffEF .. l'
�Fy T $tfy
tTJ:[ �Y X�F'.. r1
6'Y7'7yW j1 tl
t
(i+ '! k'
i�s•
! r. f Sj-:}a
t+>>x. '`jy+4'' F J aY'{.Yri; ..''7,
"_F,
+�.{.�!''!:.�w •-yLr`est
tT
'V 4-' 4" ,
F 4F. � H....,'.Y�ttt,°yyxP( 1. �� .jlE X f,� "i .:Y�r 'F'.'•�,
' {. X:i
e� .L.11 (.,
;
!�t.S
!r t
!
1 Y+. y t
_ r4.r
f 4 Fri
c.lka i..
_c r�,.r
Run Initiation Time: 04/07/09.14:39:04 Run Code: 1239140344
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number:
Page:7 of 17
r
L
r
L
4
CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG-1-C
PROJECT NAME
Bob Edwards Construction-Addition
DATE
4/9/2009
esigner:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance
tests for lighting systems. The designer is required to check the boxes by all acceptance tests that
apply and list all equipment that require an acceptance test. If all equipment of a certain type requires
a test, list the equipment description and the number of systems to be tested in parentheses. The NJ
number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the
test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design
professional or an agent selected by the owner). Since this form will be part of the plans, completion
of this section will allow the responsible party to budget for the scope of work appropriately.
Building Departments:
Before an Occupancy permit is granted for a newly constructed building or space, or a new lighting
system system serving a building or space is operated for normal use, all control devices serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department
that:
A. Certifies plans, specifications, installation certificates,, and operating and maintenance
information meet the requirements of§ 10-103(b) and Title 24 Part 6.
Test Description
Test Performed BY:
❑ LTG-2-A: Lighting Control Acceptance Document '
- Occupancy Sensor Acceptance
- Manual Daylight Controls Acceptance
- Automatic Time Switch Control Acceptance
Equipment requiring acceptance testing Ti inn e-c to c.bt.
�.� c;' a c>+,
mo'''t r
❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document
Equipment requiring acceptance testing
EnerovPro 4.4 by EnerovSoft User Number: 6712 Job Number: Page:8 of 17 1
INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C
NAME
Bob Edwards Construction -Addition
DATE
4/9/2009
Luminaire
Lamps/Ballasts
Installed Watts
C
D
E
F
G
H
I
J
Name
Type Description
�cri
�3
fD,
r
r- r-
X33.
�yQ
N NO
oriv�
3�0'
V N
c:
3.�3
���
N N
NNO
r
3��
��x
y y
ry
v
mn
Em
-c:
•J
r
z
3. 2
X03
_ Cr
fD
y
5
wm
-4x1M
C.
(1) 26w Compact Fluorescent Triple 4 Pin
Elec
CFTR26W/GX24 -3
1
26
1.0
28.0
X
6
168
PAGE TOTAL 168
BUILDING TOTAL (sum of all pages) 168
PORTABLE LIGHTING (From LTG -3-C) D
CONTROL CREDIT (From LTG -4-C) D
. ADJUSTED ACTUAL WATTS 168
Run Initiation Time: 04/07/09-14:39:04 Run Code: 1239140344
EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page:9 of 17
r
i
4
ENVELOPE MANDATORY MEASURES ENV -MM
ECT NAME
Bob Edwards Construction -Addition
DATE
4/9/2009
DESCRIPTION
Designer
Enforcement
§118(a) Installed Insulating Material shall have been certified by the manufacturer to
comply with the California Quality Standards for insulating material, Title 20,
Chapter 4, Article 3.
X❑ § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
X] §117(a) All Exterior Joints and openings in the building that are observable sources of air
leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.
X] § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors
and fire doors).
a§ 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must be labeled for U -value according to NFRC procedures.
❑ §118(e) Demising Walls in Nonresidential Buildings`.
The opaque portions of framed demising walls in nonresidential buildings shall
have insulation with an installed R -value of no less than R-13 between framing
members.
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:10 of 17
BROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -7-C
PROJECT NAME Bob Edwards Construction -Addition
ATION AUTHOR
FOR ENFORCEMENT AGENCY USE ONLY
DATE PLAN CHECK BY DATE
A1010000 I
A
B
C
D
E
F
Room
Name
Task/Activity
Description
Room
Length (L)
ft
Room
Width (W)
ft
Room Cavity
Height (H)
(ft)
Room Cay. Ratio
5xHx(L+W)
/(LxW)
Room
Task/Activity
Area (A)
Perimeter (P)
Height (H)
2.5 x H x P
Name
Description
M
(ft)
(ft)
/A
A
B
C
D
E
F
Room
Room
Room Cavity
Room Cay. Ratio
Room
Task/Activity
Area (A)
Perimeter (P)
Height (H)
2.5 x H x P
Name
Description
M
(ft)
(ft)
/A
EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page: 11 of 17
4
F,
CERTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-1-C
PROJECT NAME
DATE
Bob Edwards Construction -Addition
4/9/20.09
ROJECT ADDRESS
i�� "
51-455 Desert Club Drive La Quinta
Building Permit #
PRINCIPAL DESIGNER - LIGHTING
TELEPHONE
Robert Pitchford, Architect
(760) 346-8776
DOCUMENTATION AUTHOR
TELEPHONE
'';Checked by/Date
Scott Design & Title 24
(760) 200-4780
EntorcementAgency 'use
GENERAL INFORMATION
DATE OF PLANSOUTDOOR
LIGHTING ZONE
❑ LZ1 ❑ LZ2 [K LZ3 ❑ LZ4
FUNCTION TYPE ❑X OUTDOOR LIGHTING ❑ OUTDOOR SIGNS ❑INDOOR SIGNS
PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION ® ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the outdoor lighting system specifications need to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations.
This certificate applies only to building lighting requirements.
The documentation preparer hereby certifies that the documentation is accurate and complete.
DOCUMENTATION AUTHOR
SIGNATURE
DATE
Jon Scott
<!F—
I Li • 9 -01
The Principal Lighting Designer hereby certifies that the proposed outdoor lighting and signs design represented in this set of
construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other
calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements
contained in Sections 110, 119, 130 through 132, and 146,and 149 of Title 24, Part 6.
lease Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.)
I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this
document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer
or electrical engineer, or I am a licensed architect.
❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or
6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing
this work.
❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code
Sections 5537, 5538 and 6737.1.
PRINCIPAL LIGHTING DESIGNER - NAME DATE LIC. #
Robert Pitchford Architect CI C�23i
LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included
®OLTG-1-C: Certificate of Compliance. Required on plans for all submittals for outdoor lighting. Part 2 of 2 may be incorporated in schedules on the p
Either LTG -1-C or OLTG-I-C may be used for signs as follows:
1. Use LTG -1-C if the project consists solely of indoor signs.
2. Use LTG -1-C if the project consists of indoor lighting, outdoor or indoor signs, but no other outdoor lighting.
3. Use OLTG-I-C if the project consists solely of outdoor signs.
4. Use OLTG-I-C if the project consists of outdoor lighting, outdoor or indoor signs, but no other indoor lighting.
®OLTG-2-C: LIGHTING COMPLIANCE SUMMARY. Applicable parts required for ALL outdoor lighting allowances (Except Signs). -
OLTG-3-C: AREA CALCULATIONS WORKSHEET. Applicable parts required for all outdoor area calculations.
OLTG-4-C: SIGN LIGHTING COMPLIANCE. Required for all internally and externally illuminated signs, for both indoor and outdoor
signs.
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 17
pans.
CERTIFICATE OF COMPLIANCE (Part 2 of 2) OLTG-1-C
PROJECT NAME
Bob Edwards Construction -Addition
DATE
4/9/2009
ijhting Schedules on Plans Show that Outdoor Lightina Meets Allowed Lighting Power
❑X
❑
Lighting power allowance for general site Illumination on OLTG-2-C Part 1 of 4
Not Applicable
❑
❑X
Lighting power allowance for local ordinances or for security multipliers on OLTG-2-C Part 2 of 4
Not Applicable
❑
❑X
Lighting power allowances for specific applications, other than vehicle service stations with canopies on OLTG-2-C Part 3 of 4
Not Applicable
❑
❑X
Lighting power allowances for vehicle service station canopies on OLTG-2-C part 4 of 4
Not Applicable
❑
❑X
Sign lighting compliance on OLTG-4-C
Not Applicable
Mandatont
❑X
❑
Measures on Plans Show that Outdoor Liahtina Meets Outdoor Liahtina Controls
Installed lighting power has been determined In accordance with Section 130(c)1
Not Applicable
❑
❑X
All permanently Installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumins per Watt or are
controlled by a motion sensor per Section 132(a)
Not Applicable
❑X
❑
All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances, canopies, and all
outdoor sales areas meet the Cutoff Requirements of Section 132(b)
Not Applicable
❑X
F—]
All permanently Installed outdoor lighting meets the control requirements of Section 132(c)1
NotApplicable
❑
❑X
Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements of Section 132(c)
Not Applicable
MANDATORY AUTOMATIC CONTROLS
'NOTE TO
AREA CONTROLLED FIELD
CONTROL LOCATION
(Room #)
CONTROL
IDENTIFICATION
CONTROL TYPE
(Auto Time Switch, Dimming, etc.)
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 13 of 17
LIGHTING COMPLIANCE SUMMARY (Part 1 of 4) OLTG-2-C
Name
Bob Edwards Construction -Addition
Date
4/9/2009
LIGHTING POWER ALLOWANCES
- GENERAL
SITE ILLUMINATION - Table 147-A
Allotted Watts
Luminaire
Lamps/Ballasts
installed Watts
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Lighting Application
Category
(Table 147-A)
r m
o °;
H0H
a
T
D
�L—
�xm
rya
�+� r
o °v
D
p
Wa
c��
m
F
o
a
m
Description
m e
�$
°:
,� cri
v3
�o o
r
cd
3 3
7N
d,�
'm m
cri
3
0,0
M
cm
3 y
��
d.�
CD
c�
3
'v.v
m' m
n
n
v
—
r
rc
3.3
ym
H°
_ Sri
r(D
xa
Z
v obi
South Entry
22
0.70
158
(1) 26w Compact Fluorescent
Triple 4 Pin Elec
1
26
1.0
28.0
X
2
5
West Entry
27C
0.70
189
(1) 26w Compact Fluorescent
Tri le 4 Pin Elec
1
26
1.0
28.0
X
1
28
Total Allotted Watts 346
•
Total Installed Watts F�
I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 14 of 17 1
r
L
ILLUMINATED AREA CALCULATION WORKSHEET (Part 2 of 5) OLTG-3-C
PROJECT NAME
Bob Edwards Construction-Addition
DATE
4/9/2009
Hardsca a Method. ii
Hardsca a for driveways, site roads, sidewalks, walkways and bikeways
A
B
List Specific Application (Table 147-A)
Length of 25' wide path incorporating as
much of he paved area as possible.
15
225
15
18
270
Checklist
❑ Section 147 (c)1 9 - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas.
❑ Section 147 (c)1 B Method ii - General. illumination areas for site roadway, driveway, sidewalk, walkway, or bikeway includes only those illuminated areas that are in the
bounds of the Application and includes a 25 foot wide area running along the axis of the path of travel and much of the paved area as possible.
4
B. Buildin-q Entrances without Cano ies
A
B
C
Width of Door plus 3 feet on each side
Width
Smaller of 18 ft or distance to the edge of the
property line
Areas
(A x a) —
15
15
225
15
18
270
Checklist
❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with the actual use of the
areas.
Section 147 (c)1 A - General illumination areas includes only those illuminated areas that in the bounds of the Application and are with a square pattern around a
❑ luminaire that is six times the luminaire mounting height, with the luminaire in the middle of the pattern, less any areas that are within buildings, under canopies, beyond
property lines, or obstructed by a signs or other structures.
0
I EneravPro 4.4 by EneravSoft User Number: 6712 Job Number: Page: 15 of 17 1
4
4
LIGHTING MANDATORY MEASURES LTG -MM
NAME DATE
Bob Edwards Construction -Addition I
4/9/2009
DESCRIPTION
Designer
Enforcement
❑X § 131(d)1 For every floor, all Interior lighting systems shall be equipped with a separate automatic
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automatically shutting off the lighting.
FX § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is
provided with a manual, accessible override switch In sight of the lights. The area of
override is not to exceed 5,000 square feet.
X] § 119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and Installed as directed by the
manufacturer.
X] § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the
project are certified and listed In the Directory. All Installed fixtures shall be certified.
X] § 131(a) Individual Room/Area Controls: Each room and area in this building Is equipped with
a separate switch or occupancy sensor device for each area with floor -to -ceiling
Walls.
X❑ § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
controlled with bi-level switching for uniform reduction of lighting within the room.
§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight In the area shall have
50% of the lamps In each daylit area controlled by a separate switch; or the effective
use of daylight cannot be accomplished because the windows are continuously
shaded by a building on the adjacent lot. Diagram of shading during different times
of the year is included on plans.
❑ § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are
20 amps or less.
i
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 16 of 17
(LIGHTING INSPECTION CHECKLIST LTG -I
NAME
Bob Edwards Construction -Addition
INSPECTION DATE
4/9/2009
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:17 of 17
FIXTURE
CODE
TYPE
DESCRIPTION
LAMP
TYPE
LAMP
QUANT.
NUMBER OF
FIXTURES
WATTS PER
FIXTURE
FIELD NOTES
1 26w Compact Fluorescent Triple 4 Pin Elec
1
6
28.0
Type DESCRIPTION
H METAL HALIDE
INC INCANDESCENT
INC/LV INCANDESCENT LOW VOLTAGE
CFL COMPACT FLUORESCENT
FL FLUORESCENT
OTHER.
EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:17 of 17