07-0617 (RC)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
I
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/14/07
Application Number: L07=00000617
Owner:
Property Address: 51555 DESERT CLUB DRCSTE -400 /
KELLY JAMES F
rt APN: 770-182-001- - �-_�!
Property Zoning: VILLAGE COMMERCIAL
Application valuation: 10000Contractor:DEC
[1;
14
2007Applicant:
Architect or Engineer:
KELLY PACIFIC CONSTRUCTIONl•1100
UGREENBRAE,
DRAKE'S LANDING ROAD,
CA 94904
1TMCF�QUINTA
FINANCE
(415)464-0900
DEPT.
Lic. No.: 346196 -
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 346196
C Date: /4a//yZ7Contraact-or:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who doei the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
C
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier -and policy number are:
Carrier STATE FUND Policy Number 0001375-2007
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if 1 should become subject to the workers' compensation provisions of Section
'
3700 of the Labor Code, I shall forthwit omp ith those provisions.
Applicant: --.
WARNING: FAILURE TO SECU WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED -FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
ACKNOWLEDGEMENT
IMPORTANT Application is hereby made t he Director o - wilding and Safety for a permit subject to the
condition_ s and restrictions set forth on IN application.
1. Each person upon whose be alf this application is m de, each person at whose request and for
whose benefit work is perf rmed under or pursuant to\any permit issued as a result of this application,
the owner, and the applicaht, each agrees to, and shall �d fend, indemnify and hold harmless the City
of La Quinta, its officers, aents and employees for any a t or omission related to the work being
performed under or following g issuance of this permit.
2. Any permit issued as a result of this application becomes nul and void if work is not commenced
within 180 days from date of issuance of such permit, or ces ation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application a h d state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and'Nhereby authorize representatives
of this county to enter upon the above-mentioned property for inspection rpose
Date: :f�/a/ Signature (Applicant or Agentl: ��
-00000617
Application Number 07
Structure Information 851SF TI/B-OCC/9-OL [OFFICE SPACE]
Other struct info
CODE EDITION
2001/2004/2005
FIRE SPRINKLERS
YES
MIXED-USE OCCUPANCY
B
OCCUPANT LOAD
9.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
851.00
Permit . . .
BUILDING PERMIT
Additional desc . .
Permit Fee . . . .
117.00 Plan Check Fee
76.05
Issue Date . . . .
Valuation . .
. . 10000
Expiration Date
6/11/08.
Qty Unit Charge
Per
Extension
BASE FEE
45.00
8.00 9.0000
----------------------------------------------------------------------------
THOU BLDG 2,001-25,000
72.00
Permit . . .
ELECT. - ADD/ALT/REM
Additional desc .
Permit Fee
43.05 Plan Check Fee
10.76
Issue Date
Valuation
0
Expiration Date
6/11/08
Qty Unit Charge
Per
Extension
BASE FEE
15.00
20.00 .7500
PER ELEC DEVICE/FIXTURE 1ST 20
15.00
29.00 .4500
-------------------------------------------
EA ELEC DEVICE/FIXTURE >20
--------------------------------
13.05
Permit . . .'
MECHANICAL
Additional desc .
Permit Fee . . . .
19.50- Plan Check Fee
f 4.88
Issue Date . . . .
Valuation . .
. . 0
Expiration Date
6/11/08
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 4.5000
----------------------------------------------------------------------------
EA MECH VENT INST/ DUCT ALT
4.50
Permit . . . . . .
PLUMBING
Additional desc . .
I
Permit Fee
24.00 Plan Check Fee
6.00
Issue Date
Valuation
0
Expiration Date
6/11/08
A
LQPERAIIT
LQPERAIJT
Application Number. 07-00000617
s
'
Permit . . . . . PLUMBING
Qty Unit Charge Per
Extension
BASE .FEE
15.00.
1.00 6.0000 EA PLB FIXTURE
6.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
-------------------------------------7--------------------------------------
Special Notes and Comnients
851SF TENANT IMPROVEMENT/B-OCC/9-OL
[OFFICE, SUITE #4001 2001 CBC, CPC, CMC,
2004 CEC, 2005 ENERGY. CARPORTS HAVE
BEEN COMPLETE AS OF 12/3/2007:
December 13, 2007 8:41:14 AM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW
7.60
ENERGY REVIEW FEE
7.60
Fee summary Charged. Paid Credited
Due
Permit Fee Total 203.55 .00 .00
203.55
Plan Check Total 97.69 .00 .00
97.69
Other Fee Total. 15.20 .00 .00
15.20 '
Grand Total 316.44 .00 .00
316.44
J '
f
I ,
CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1 -C
PROJECT NAME
DATE
Kelly Pacific, Ste. 400
2/20/2007
PROJECT ADDRESS
51-555 Desert Club Drive La Quinta
#
PRINCIPAL DESIGNER - LIGHTING
TELEPHONE
Building Permit
Randy Moss
760-340-9005
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
MRC Engineering, Inc.
(760) 340-9005
1 Enforcement Agency Use
GENERAL INFORMATION
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
CLIMATE ZONE
$51 Sq.Ft.
1 15
BUILDING TYPE O NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM
❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS
PHASE OF CONSTRUCTION ❑X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION
METHOD OF LIGHTING XJ COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE
COMPLIANCE ❑ COMMON LIGHTING
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24,
Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements.
The documentation preparer hereby certifies that the documentation is ac rate and complete.
DOCUMENTATION AUTHOR
SIGNATUREDATE
i
Deborah ConwayFL/
2
j�
- d21�'
The Principal Lighting Designer hereby certifies that the proposed building design represented in th' set of construction documents
is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with
this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119,
130 - 132, 146, 148 & 149 of Title 24, Part 6.
❑ The pians & specifications meet the requirements of Part 6 (Sections 10-103a).
❑ The installation certificates meet the requirements of Part 6 (10-103a 3).
❑ The operation & maintenance information meet the requirements of Part 6 (10-103c).
Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.)
❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person
responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect.
❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document
as the person responsible for its preparation; and that I am a licensed contractor performing this work.
I affirm that I am eligible under the exemption to Division 3 of the Busi s and Professions Code to sign this document because it pertains to a
structure or type of work described as exempt pursuant to Business Profe ions Code Sections 5537, 5538 and 6737.1.
PRINCIPAL LIGHTING DESIGNER - NAME G URE
DATE LIC. #
Randy Moss
- '151-3 S
LIGHTING MANDATORY MEASURES
Indicate location on plans of Note Block for Mandatory Measures
LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included
OLTG-1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals
❑LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed
I -lx LTG -1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed
IXILTG-2-C: Indoor Lighting Schedule
❑LTG -3-C: Portable Lighting Worksheet officz-
OLTG-4-C: Lighting Controls Credit Worksheet CITY OF LA QUINTA
XLTG-5-C: Indoor Lighting Power Allowance
❑LTG -6-C: Tailored Method Worksheet BUILDING & SAFETY DEPT.
❑ LTG -7-C: Room Cavity Ratio Worksheet APPROVED
❑LTG -8-C: Common Lighting Systems Method Worksheet FOR CONSTRUCTION
❑LTG -9-C: Line Voltage Track Lighting Worksheet
EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: ge:1 of 6
DATE'InT13Y cW I
19
CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 -C
PROJECT NAME DATE
Kelly Pacific, Ste. 400 1
2/20/2007
INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES
INSTALLED
WATTS
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 900
PORTABLE LIGHTING (From LTG -3-C) 0
LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0'
CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 900
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0
ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES
❑X COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED
❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS
❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 936
ALTERNATE COMPLIANCE
❑ PERFORMANCE METHOD
❑ COMMMON LIGHTING SYSTEM (From LTG -8-C)
ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0
MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS
CONTROL LOCATION
(Room #)
CONTROL
IDENTIFICATION
CONTROL TYPE
Time Switch, Dimming, etc.)
Check if
SPACE CONTROLLED Daylighting
NOTE TO
FIELD
NOTES TO FIELD - For Buildinci
Department Use Only
EnergyPro 4.3 by EnergySoft
User Number: 6429 Job Number: Page:2 of 6
(CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG -1-C
PROJECT NAME
Kelly Pacific, Ste. 400
DATE
2/20/2007
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance
tests for lighting systems. The designer is required to check the boxes by all acceptance tests that
apply and list all equipment that require an acceptance test. If all equipment of a certain type requires
a test, list the equipment description and the number of systems to be tested in parentheses. The NJ
number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the
test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design
professional or an agent selected by the owner). Since this form will be part of the plans, completion
of this section will allow the responsible party to budget for the scope of work appropriately.
Building Departments:
Before an occupancy permit is granted for a newly constructed building or space, or a new lighting
system system serving a building or space is operated for normal use, all control devices serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department
that:
A. Certifies plans, specifications, installation certificates, and operating and maintenance
information meet the requirements of§ 10-103(b) and Title 24 Part 6.
Test Description
Test Performed By:
❑ LTG -2-A: Lighting Control Acceptance Document
- Occupancy Sensor Acceptance
- Manual Daylight Controls Acceptance
- Automatic Time Switch Control Acceptance
Equipment requiring acceptance testing
❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document
Equipment requiring acceptance testing
EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:3 of 6 1
INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -
NAME DATE
Kelly Pacific, Ste. 400 2/20/2007
INSTALLED LIGHTING POWER FOR CONDITIONED SPACES
Luminaire
Lamps/Ballasts
Installed Watts
C
D
E
F
G
H
I
J
Name
Type Description
-iv
-03
N-0
c°r'c
3 3 3
��v Q
N N
m ° °
my
3mm
N
r- CO
3.0> 3
S^Q
d f�D
m `��° °
c
3�
5�`x
Ol y
m
O
m n
cm
_0
a
r
c 2
3 c
n5 3
_
(D
G)��
x m
-rn fD
n
1
(3) 4 ft Fluorescent T8
F32T8
31
30
1.0
79.0
X
10
790
2
(2) 26w Compact Fluorescent
CU-X2.4g-
2
26
1.0
55.0
X
2
110
PAGE TOTAL 9OO
BUILDING TOTAL (sum of all pages) 9OO
PORTABLE LIGHTING (From LTG -3-C)
CONTROL CREDIT (From LTG -4-C) O
ADJUSTED ACTUAL WATTS 9OO
EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:4 of 6 1
J'NbOOR LIGHTING POWER ALLOWANCE LTG -5 -
PROJECT NAME
Kelly Pacific Ste. 400
DATE
2/20/2007
ALLOWED LIGHTING P0ZffMQhoose
COMPLETE BUILDING METHOD - CONDITIONED SPACES
ALLOWED
WATTS
WATTS
PER SF
COMPLETE
BLDG. AREA
ALLOWED
WATTS
BUILDING CATEGORY (From Section 146 Table 146-13)
Comp Bldg Medical and Clinic
1.10
851
936
AREA CATEGORY METHOD - CONDITIONED SPACES
AREA
(SF)
ALLOWED
WATTS
AREA CATEGORY (From Section 146 Table 146-C)
WATTS
PER SF
PAGE TOTAL
BUILDING TOTAL
D
D
D
D
AREA
WATTS
TAILORED METHOD - UNCONDITIONED SPACES
TOTAL UNCONDITIONED SPACES ALLOWED WATTS
(From LTG -5-C and LTG -6-C)
EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:5 of 6
PAGE TOTAL
BUILDING TOTAL
D
D
AREA
WATTS
TAILORED METHOD - CONDITIONED SPACES
TOTAL ALLOWED WATTS
(From LTG -6-C or from computer run.)
D
UNCONDITIONED SPACES
Complete Building and Area Catagory Methods
Category (From Section 146 Table 146 -B&C)
WATTS
PER SF
AREA
(SF)
ALLOWED
WATTS
PAGE TOTAL
BUILDING TOTAL
D
D
D
D
AREA
WATTS
TAILORED METHOD - UNCONDITIONED SPACES
TOTAL UNCONDITIONED SPACES ALLOWED WATTS
(From LTG -5-C and LTG -6-C)
EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:5 of 6
LIGHTING MANDATORY MEASURES LTG -MM
PROJECT NAME DATE
Kelly Pacific. Ste. 400 1 1
2/20/2007
DESCRIPTION
Designer
Enforcement
0 §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automatically shutting off the lighting.
§131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is
provided with a manual, accessible override switch in sight of the lights. The area
of override is not to exceed 5,000 square feet.
0 §119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and installed as directed by the
manufacturer.
F§111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for
the project are certified and listed in the Directory. All installed fixtures shall be
certified.
X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three
lamp fluorescent fixtures are tandem wired with two lamp ballasts where required
by Standards Section 132; or all one and three lamp fluorescent fixtures are
specified with electronic high -frequency ballasts and are exempt from tandem
wiring requirements.
X] §131(a) Individual Room/Area Controls: Each room and area in this building is equipped
with a separate switch or occupancy sensor device for each area with floor -to -
ceiling walls.
§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
controlled with bi-level switching for uniform reduction of lighting within the room.
§131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight in the area shall
have 50% of the lamps in each daylit area controlled by a separate switch; or the
effective use of daylight cannot be accomplished because the windows are
continuously shaded by a building on the adjacent lot. Diagram of shading during
different times of the year is included on plans.
❑ §131(e) Display Lighting. Display lighting shall be separately switched on circuits that
are 20 amps or less.
EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:6 of 6
John R. Hawkins
Fire Chief
Proudly serving the
Unincorporated.
Areas of Riverside
County and the
Cities of:
Banning
Beaumont
4.
Calimesa
Canyon Lake
Coachella
Desert Hot Springs
Indian Wells
Indio
Lake Elsinore
La Quinta
Moreno Valley
41 -
Palm Desert
Perris
:-
Rancho Mirage
4.
San Jacinto
Temecula
Board of Supervisors
Bob Buster,
District I
John Tavaglione,
District 2
Jim Venable,
District 3
Roy Wilson,
District 4
Marion Ashley,
District 5
RIVERSIDE COUNTY FIRE DEPARTMENT
In cooperation with the
California Department of Forestry and Fire Protection
210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910
April 3, 2007,
Kelly Pacific Construction
100 Drakes Landing
Greenbrae, CA 94904
RE: TENANT IMPROVEMENT PLAN CHECK
LAQ-07-TI-023 / Barcelona at 51555 Desert Club Drive, Ste 400, La Quinta, CA
You have been issued a release for a tenant improvement on an existing building. THIS IS
NOT AN OCCUPANCY PERMIT.
It is prohibited to use/process or store any materials in this occupancy that would classify it
as an "H" occupancy per Sec. 307 of the 2000 UBC.
THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION:
Install door hardware and exit signs as per Chapter 10 of the 2000 UBC.
Install Knox Lock Boxes, Models 4400, 3200 or 1300, mounted per recommended standard
of the Knox Company. Plans must be submitted to the Fire Department for approval of
mounting location/position and operating standards. Special forms are available from this
office for the ordering of the Key Lock Boxes. This form must be authorized and signed by
this office for the correctly coded system to be purchased. If the building/facility is protected
with a fire alarm system or burglar alarm system, the lock boxes will require "tamper"
monitoring.
A minimum 2A10BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a
visible location within 75' walking distance from any point in your building or suite. Fire
extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal
service tag attached to the extinguisher, & purchased from a retail store with a sales receipt
attached. A licensed fire extinguisher company must service extinguisher yearly.
ELECTRICAL PANEL BOX:
All breakers must be labeled and a clearance of 36 inches must be maintained around the
panel at all times.
OTHER REQUIREMENTS:
Approved building address shall be placed in such a position a to be plainly visible and
legible from the street. Said numbers shall contrast with their background.
A durable sign stating "This door to remain unlocked during business hours" shall be placed
on or adjacent to the front exit door. The sign shall be in letters not less than one inch high
on a contrasting background.
Applicant/installer shall be responsible to contact the Fire Department to schedule
inspections. A re-inspectiomlbeEadflsbvmeWkmdrNi nxwe*mnrwei(40nuRction is necessary.
82-6675 Highway 111, 2n° FI., Indio, CA 92201 . (760) 863-8886 • Fax (760) 863-7072
Requests for inspections are to be made at least 72 hours in advance and may be arra,.,- d
by calling (760) 863-8886.
All questions regarding the meaning of these conditions should be referred to the Fire
Department Planning & Engineering Staff at (760) 863-8886.
Sincerely,
Tracy Hobday
Chief Fire Department Planner
By:
Sonia Coo
le
Fire Safety Specialis
0
P.O.. Box 1504
78-495 CALLE TAMP.ICO
LA QUINTA, CALIFORNIA 92253
To: Greg Butler, Building & Safety Manager
From: Doug Evans, Director -CDD
P/C #:.07-617
BUILDING & SAFETY DEPARTMENT
.(760)777-7012
FAX (760) 777-7011
To CDD: December 6, 2007
Due Date: December 13, 2007
Status: 2"d Review
Building Plans Approval
(This is an approval to issue a Building Permit)
The Community Development Department has reviewed the Building Plans for
the following project:
Description: Tenant Improvement - Office Buildinq
Addressor General Location: 51-555 Desert Club Drive Suite 400
Applicant Contact: Larry (760) 776-4068
The Community Development Departm6nt finds that:
❑ ...these Building Plans do not require Community Development
D artment approval.
...these Building Plans are approved by the Community Development
Department.
❑ ...these Building Plans require corrections. Please forward a copy of the
attached corrections to the applicant. When the corrections are made
please return them to the Community Development Department for
review.
vans, Director -CDD
/2- -7 - zoo
Date
I TITLE 24 REPORT I
Title 24 Report for:
Desert Southwest Insurance Brokers
51-555 Desert Club Dr.
La Quinta, CA 92253
Project Designer:
Deborah Conway
72880 Fred Waring Dr., Ste. C-11
Palm Desert, CA 92260
760-340-9005
Report Prepared By:
Deborah Conway
MRC Engineering, Inc.
72-880 Fred Waring Drive, C11
Palm Desert, CA 92260.
(760) 34079005
CITY OF to QUINTA Job Number:
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA Date:
10/27/2006
�l OCT 3i 2006 I U
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
I EnergyPro 4.2 by EnergySoft Job Number. User Number. 6429 I
CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1 -C
PROJECT NAME
DATE
Desert Southwest Insurance Brokers
10/27/2006
PROJECT ADDRESS
51-555 Desert Club Dr. La Quinta
PRINCIPAL DESIGNER - LIGHTING
TELEPHONE
Building Permit #
Randy Moss
760-340-9005
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
MRC Engineering, Inc.
760 340-9005
Enforcement A en Use
GENERAL INFORMATION
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
CLIMATE ZONE
10-27-06
747 Sq.Ft.
1 15
BUILDING TYPE ❑X NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM
❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS
PHASE OF CONSTRUCTION [X] NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION
METHOD OF LIGHTING 0 COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE
COMPLIANCE ❑ COMMON LIGHTING
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24,
Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements.
The documentation preparer hereby certifies that the documentation is accur to a d complete.
DOCUMENTATION AUTHOR
SIGNATURE
DATE
Deborah ConwayAz-14z'/0-
/D -.?i o U
The Principal Lighting Designer hereby certifies that the proposed building design represented in this s t of construction documents
is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with
this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119,
130 - 132, 146, 148 & 149 of Title 24, Part 6.
❑ The plans & specifications meet the requirements of Part 6 (Sections 10-103a).
❑ The installation certificates meet the requirements of Part 6 (10-103a 3).
❑ The operation & maintenance information meet the requirements of Part 6 (10-103c).
Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.)
❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person
responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect.
❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document
as the person responsible for its preparation; and that I am a licensed contractor performing this work.
❑ I affirm that I am eligible under the exemption to Division 3 of the Busin9ps and Professions Code to sign this document because it pertains to a
structure or type of work described as exempt pursuant to Business YyProfessions Code Sections 5537, 5538 and 6737.1.
PRINCIPAL LIGHTING DESIGNER -NAME
SI UR
DATE
LIC. #
Rand' Moss
.�Z 7-0
1,,E /,3 `1353
LIGHTING MANDATORY MEASURES
Indicate location on plans of Note Block for Mandatory Measures
LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included
®LTG -1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals
❑LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed
X LTG -1 -C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed
DO LTG -2-C: Indoor Lighting Schedule
❑LTG -3-C: Portable Lighting Worksheet
❑LTG -4-C: Lighting Controls Credit Worksheet
®LTG -5-C: Indoor Lighting Power Allowance
❑LTG -6-C: Tailored Method Worksheet
❑LTG -7-C: Room Cavity Ratio Worksheet
❑LTG -8-C: Common Lighting Systems Method Worksheet
❑LTG -9-C: Line Voltage Track Lighting Worksheet
EnergyPro 4.2 by EnergySoft User Number: 6429 Job Number: Page:1 of 8
CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -
PROJECT NAME DATE
Desert Southwest Insurance Brokers 1 10/27/2006
INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES
INSTALLED
WATTS -
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 754
PORTABLE LIGHTING (From LTG -3-C) 0
LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0
CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 754
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0
ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES
❑X COMPLETE BUILDING METHOD (From LTG -5-C)
❑ AREA CATEGORY METHOD (From LTG -5-C)
❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER
ALLOWED
WATTS
822
ALTERNATE COMPLIANCE
❑ PERFORMANCE METHOD
❑ COMMMON LIGHTING SYSTEM (From LTG -8-C)
ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C)
0
MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS
CONTROL LOCATIONI
(Room #).
CONTROL
IDENTIFICATION
CONTROLTYPE
(Auto Time Switch, Dimming, etc.)
Check if
SPACE CONTROLLED Daylighting
NOTE TO
FIELD
NOTES TO FIELD - For Building
Department Use Only
EnergyPro 4.2 by Energysoft
User Number. 6429 Job Number: Page:2 of 6
INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C
PROJECT NAME DATE
Desert Southwest Insurance Brokers I
10/27/2006
INSTALLED LIGHTING POWER FOR CONDITIONED SPACES
Luminaire
Lamps/Ballasts
Installed Watts
C
D
E
F
G
H
I
J
Name
Type Description
r
-03
CD -0�•'O
9.33
ym
m `�
r
3m�
pl
m a
5'acr
�.�
m `, °
C.0
9'm
1 y
m
,n
�m
J
r
c
=U=1
fD
N
w
x
.... N 4
YeS
No
1
(3) 28W T5
F724W/2G11
3
24
1.01
78.0
X
1
8
1 624
2
(2) 26w Compact Fluor.
WL
2
26
1.0
55.0
X
1
55
3
70w Surface Mount Inc.
ow
1
70
75.0
X
1
75
PAGE TOTAL 754
BUILDING TOTAL (sum of all pages) 754
PORTABLE LIGHTING (From LTG -3-C) D
CONTROL CREDIT (From LTG -4-C) O
ADJUSTED ACTUAL WATTS 754
EnerovPro 4.2 by EnergySoft User Number: 6429 Job Number: Pace:4 of 6 1
INDOOR LIGHTING POWER ALLOWANCE LTG -5-C
PROJECT NAME
Desert Southwest Insurance Brokers
DATE
10/27/2006
ALLOWgD LIGHTING POI&ERC e
COMPLETE BUILDING METHOD - CONDITIONED SPACES
ALLOWED
WATTS
WATTS
PER SF
COMPLETE
BLDG. AREA
ALLOWED
WATTS
BUILDING CATEGORY (From Section 146 Table 146-B)
Comp Bldg Office
1.10
747
822
AREA CATEGORY METHOD - CONDITIONED SPACES
AREA
(SF)
ALLOWED
WATTS
AREA CATEGORY (From Section 146 Table 146-C)
WATTS
PER SF
PAGE TOTAL
BUILDING TOTAL
D
D
D
D
AREA
WATTS
TAILORED METHOD - UNCONDITIONED SPACES
TOTAL UNCONDITIONED SPACES ALLOWED WATTS
(From LTG -5-C and LTG -6-C)
O
EnergyPro 4.2 by EnergySoft User Number. 6429 Job Number. Page:5 of 6
PAGE TOTAL
BUILDING TOTAL
D
D
AREA
WATTS
TAILORED METHOD - CONDITIONED SPACES
TOTAL ALLOWED WATTS
(From LTG -6-C or from computer run.)
D
UNCONDITIONED SPACES
Complete Building and Area Catagory Methods
Category (From Section 146 Table 146 -B&C)
WATTS
PER SF
AREA
(SF)
ALLOWED
WATTS
PAGE TOTAL
BUILDING TOTAL
D
D
D
D
AREA
WATTS
TAILORED METHOD - UNCONDITIONED SPACES
TOTAL UNCONDITIONED SPACES ALLOWED WATTS
(From LTG -5-C and LTG -6-C)
O
EnergyPro 4.2 by EnergySoft User Number. 6429 Job Number. Page:5 of 6
LIGHTING MANDATORY MEASURES LTG -MM
PROJECT NAME DATE
Desert Southwest Insurance Brokers 1 10/27/2006
DESCRIPTION
Designer
Enforcement
X❑ §131 (d)l For eve floor, all interior lighting systems shall beequipped with a separate automatic
() every � 9 9 Y
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or other device
capable of automatically shutting off the lighting.
X] 6131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is
provided with a manual, accessible override switch in sight of the lights. The area
of override is not to exceed 5,000 square feet.
X] §119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and installed as directed by the
manufacturer.
a§111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for
the project are certified and listed in the Directory. All installed fixtures shall be
certified.
X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three
lamp fluorescent fixtures are tandem wired with two lamp ballasts where required
by Standards Section 132; or all one and three lamp fluorescent fixtures are
specified with electronic high -frequency ballasts and are exempt from tandem
wiring requirements.
X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped
with a separate switch or occupancy sensor device for each area with floor -to -
ceiling walls.
a§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
controlled with bi-level switching for uniform reduction of lighting within the room.
§131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight in the area shall
have 50% of the lamps in each daylit area controlled by a separate switch; or the
effective use of daylight cannot be accomplished because the windows are
continuously shaded by a building on the adjacent lot. Diagram of shading during
different times of the year is included on plans.
§131(e) Display Lighting. Display lighting shall be separately switched on circuits that
are 20 amps or less.
EnergyPro 4.2 by EnergySoft User Number: 6429 Job Number. Page:6 of 6