Loading...
07-0617 (RC)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 I BUILDING & SAFETY DEPARTMENT BUILDING PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/14/07 Application Number: L07=00000617 Owner: Property Address: 51555 DESERT CLUB DRCSTE -400 / KELLY JAMES F rt APN: 770-182-001- - �-_�! Property Zoning: VILLAGE COMMERCIAL Application valuation: 10000Contractor:DEC [1; 14 2007Applicant: Architect or Engineer: KELLY PACIFIC CONSTRUCTIONl•1100 UGREENBRAE, DRAKE'S LANDING ROAD, CA 94904 1TMCF�QUINTA FINANCE (415)464-0900 DEPT. Lic. No.: 346196 - LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 346196 C Date: /4a//yZ7Contraact-or: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who doei the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT C WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier -and policy number are: Carrier STATE FUND Policy Number 0001375-2007 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section ' 3700 of the Labor Code, I shall forthwit omp ith those provisions. Applicant: --. WARNING: FAILURE TO SECU WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED -FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. ACKNOWLEDGEMENT IMPORTANT Application is hereby made t he Director o - wilding and Safety for a permit subject to the condition_ s and restrictions set forth on IN application. 1. Each person upon whose be alf this application is m de, each person at whose request and for whose benefit work is perf rmed under or pursuant to\any permit issued as a result of this application, the owner, and the applicaht, each agrees to, and shall �d fend, indemnify and hold harmless the City of La Quinta, its officers, aents and employees for any a t or omission related to the work being performed under or following g issuance of this permit. 2. Any permit issued as a result of this application becomes nul and void if work is not commenced within 180 days from date of issuance of such permit, or ces ation of work for 180 days will subject permit to cancellation. I certify that I have read this application a h d state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and'Nhereby authorize representatives of this county to enter upon the above-mentioned property for inspection rpose Date: :f�/a/ Signature (Applicant or Agentl: �� -00000617 Application Number 07 Structure Information 851SF TI/B-OCC/9-OL [OFFICE SPACE] Other struct info CODE EDITION 2001/2004/2005 FIRE SPRINKLERS YES MIXED-USE OCCUPANCY B OCCUPANT LOAD 9.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 851.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 117.00 Plan Check Fee 76.05 Issue Date . . . . Valuation . . . . 10000 Expiration Date 6/11/08. Qty Unit Charge Per Extension BASE FEE 45.00 8.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 72.00 Permit . . . ELECT. - ADD/ALT/REM Additional desc . Permit Fee 43.05 Plan Check Fee 10.76 Issue Date Valuation 0 Expiration Date 6/11/08 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 29.00 .4500 ------------------------------------------- EA ELEC DEVICE/FIXTURE >20 -------------------------------- 13.05 Permit . . .' MECHANICAL Additional desc . Permit Fee . . . . 19.50- Plan Check Fee f 4.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/11/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 ---------------------------------------------------------------------------- EA MECH VENT INST/ DUCT ALT 4.50 Permit . . . . . . PLUMBING Additional desc . . I Permit Fee 24.00 Plan Check Fee 6.00 Issue Date Valuation 0 Expiration Date 6/11/08 A LQPERAIIT LQPERAIJT Application Number. 07-00000617 s ' Permit . . . . . PLUMBING Qty Unit Charge Per Extension BASE .FEE 15.00. 1.00 6.0000 EA PLB FIXTURE 6.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 -------------------------------------7-------------------------------------- Special Notes and Comnients 851SF TENANT IMPROVEMENT/B-OCC/9-OL [OFFICE, SUITE #4001 2001 CBC, CPC, CMC, 2004 CEC, 2005 ENERGY. CARPORTS HAVE BEEN COMPLETE AS OF 12/3/2007: December 13, 2007 8:41:14 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 7.60 ENERGY REVIEW FEE 7.60 Fee summary Charged. Paid Credited Due Permit Fee Total 203.55 .00 .00 203.55 Plan Check Total 97.69 .00 .00 97.69 Other Fee Total. 15.20 .00 .00 15.20 ' Grand Total 316.44 .00 .00 316.44 J ' f I , CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1 -C PROJECT NAME DATE Kelly Pacific, Ste. 400 2/20/2007 PROJECT ADDRESS 51-555 Desert Club Drive La Quinta # PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit Randy Moss 760-340-9005 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date MRC Engineering, Inc. (760) 340-9005 1 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE $51 Sq.Ft. 1 15 BUILDING TYPE O NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION METHOD OF LIGHTING XJ COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is ac rate and complete. DOCUMENTATION AUTHOR SIGNATUREDATE i Deborah ConwayFL/ 2 j� - d21�' The Principal Lighting Designer hereby certifies that the proposed building design represented in th' set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 - 132, 146, 148 & 149 of Title 24, Part 6. ❑ The pians & specifications meet the requirements of Part 6 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 6 (10-103a 3). ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under the exemption to Division 3 of the Busi s and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business Profe ions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME G URE DATE LIC. # Randy Moss - '151-3 S LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included OLTG-1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals ❑LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed I -lx LTG -1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed IXILTG-2-C: Indoor Lighting Schedule ❑LTG -3-C: Portable Lighting Worksheet officz- OLTG-4-C: Lighting Controls Credit Worksheet CITY OF LA QUINTA XLTG-5-C: Indoor Lighting Power Allowance ❑LTG -6-C: Tailored Method Worksheet BUILDING & SAFETY DEPT. ❑ LTG -7-C: Room Cavity Ratio Worksheet APPROVED ❑LTG -8-C: Common Lighting Systems Method Worksheet FOR CONSTRUCTION ❑LTG -9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: ge:1 of 6 DATE'InT13Y cW I 19 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 -C PROJECT NAME DATE Kelly Pacific, Ste. 400 1 2/20/2007 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 900 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0' CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 900 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑X COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 936 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE Time Switch, Dimming, etc.) Check if SPACE CONTROLLED Daylighting NOTE TO FIELD NOTES TO FIELD - For Buildinci Department Use Only EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:2 of 6 (CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG -1-C PROJECT NAME Kelly Pacific, Ste. 400 DATE 2/20/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: ❑ LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:3 of 6 1 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG - NAME DATE Kelly Pacific, Ste. 400 2/20/2007 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description -iv -03 N-0 c°r'c 3 3 3 ��v Q N N m ° ° my 3mm N r- CO 3.0> 3 S^Q d f�D m `��° ° c 3� 5�`x Ol y m O m n cm _0 a r c 2 3 c n5 3 _ (D G)�� x m -rn fD n 1 (3) 4 ft Fluorescent T8 F32T8 31 30 1.0 79.0 X 10 790 2 (2) 26w Compact Fluorescent CU-X2.4g- 2 26 1.0 55.0 X 2 110 PAGE TOTAL 9OO BUILDING TOTAL (sum of all pages) 9OO PORTABLE LIGHTING (From LTG -3-C) CONTROL CREDIT (From LTG -4-C) O ADJUSTED ACTUAL WATTS 9OO EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:4 of 6 1 J'NbOOR LIGHTING POWER ALLOWANCE LTG -5 - PROJECT NAME Kelly Pacific Ste. 400 DATE 2/20/2007 ALLOWED LIGHTING P0ZffMQhoose COMPLETE BUILDING METHOD - CONDITIONED SPACES ALLOWED WATTS WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From Section 146 Table 146-13) Comp Bldg Medical and Clinic 1.10 851 936 AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF PAGE TOTAL BUILDING TOTAL D D D D AREA WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:5 of 6 PAGE TOTAL BUILDING TOTAL D D AREA WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS (From LTG -6-C or from computer run.) D UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section 146 Table 146 -B&C) WATTS PER SF AREA (SF) ALLOWED WATTS PAGE TOTAL BUILDING TOTAL D D D D AREA WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:5 of 6 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME DATE Kelly Pacific. Ste. 400 1 1 2/20/2007 DESCRIPTION Designer Enforcement 0 §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. §131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. 0 §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. F§111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X] §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ❑ §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number: 6429 Job Number: Page:6 of 6 John R. Hawkins Fire Chief Proudly serving the Unincorporated. Areas of Riverside County and the Cities of: Banning Beaumont 4. Calimesa Canyon Lake Coachella Desert Hot Springs Indian Wells Indio Lake Elsinore La Quinta Moreno Valley 41 - Palm Desert Perris :- Rancho Mirage 4. San Jacinto Temecula Board of Supervisors Bob Buster, District I John Tavaglione, District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910 April 3, 2007, Kelly Pacific Construction 100 Drakes Landing Greenbrae, CA 94904 RE: TENANT IMPROVEMENT PLAN CHECK LAQ-07-TI-023 / Barcelona at 51555 Desert Club Drive, Ste 400, La Quinta, CA You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN OCCUPANCY PERMIT. It is prohibited to use/process or store any materials in this occupancy that would classify it as an "H" occupancy per Sec. 307 of the 2000 UBC. THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: Install door hardware and exit signs as per Chapter 10 of the 2000 UBC. Install Knox Lock Boxes, Models 4400, 3200 or 1300, mounted per recommended standard of the Knox Company. Plans must be submitted to the Fire Department for approval of mounting location/position and operating standards. Special forms are available from this office for the ordering of the Key Lock Boxes. This form must be authorized and signed by this office for the correctly coded system to be purchased. If the building/facility is protected with a fire alarm system or burglar alarm system, the lock boxes will require "tamper" monitoring. A minimum 2A10BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible location within 75' walking distance from any point in your building or suite. Fire extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the extinguisher, & purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. ELECTRICAL PANEL BOX: All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at all times. OTHER REQUIREMENTS: Approved building address shall be placed in such a position a to be plainly visible and legible from the street. Said numbers shall contrast with their background. A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a contrasting background. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. A re-inspectiomlbeEadflsbvmeWkmdrNi nxwe*mnrwei(40nuRction is necessary. 82-6675 Highway 111, 2n° FI., Indio, CA 92201 . (760) 863-8886 • Fax (760) 863-7072 Requests for inspections are to be made at least 72 hours in advance and may be arra,.,- d by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863-8886. Sincerely, Tracy Hobday Chief Fire Department Planner By: Sonia Coo le Fire Safety Specialis 0 P.O.. Box 1504 78-495 CALLE TAMP.ICO LA QUINTA, CALIFORNIA 92253 To: Greg Butler, Building & Safety Manager From: Doug Evans, Director -CDD P/C #:.07-617 BUILDING & SAFETY DEPARTMENT .(760)777-7012 FAX (760) 777-7011 To CDD: December 6, 2007 Due Date: December 13, 2007 Status: 2"d Review Building Plans Approval (This is an approval to issue a Building Permit) The Community Development Department has reviewed the Building Plans for the following project: Description: Tenant Improvement - Office Buildinq Addressor General Location: 51-555 Desert Club Drive Suite 400 Applicant Contact: Larry (760) 776-4068 The Community Development Departm6nt finds that: ❑ ...these Building Plans do not require Community Development D artment approval. ...these Building Plans are approved by the Community Development Department. ❑ ...these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. vans, Director -CDD /2- -7 - zoo Date I TITLE 24 REPORT I Title 24 Report for: Desert Southwest Insurance Brokers 51-555 Desert Club Dr. La Quinta, CA 92253 Project Designer: Deborah Conway 72880 Fred Waring Dr., Ste. C-11 Palm Desert, CA 92260 760-340-9005 Report Prepared By: Deborah Conway MRC Engineering, Inc. 72-880 Fred Waring Drive, C11 Palm Desert, CA 92260. (760) 34079005 CITY OF to QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA Date: 10/27/2006 �l OCT 3i 2006 I U The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. I EnergyPro 4.2 by EnergySoft Job Number. User Number. 6429 I CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1 -C PROJECT NAME DATE Desert Southwest Insurance Brokers 10/27/2006 PROJECT ADDRESS 51-555 Desert Club Dr. La Quinta PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit # Randy Moss 760-340-9005 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date MRC Engineering, Inc. 760 340-9005 Enforcement A en Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 10-27-06 747 Sq.Ft. 1 15 BUILDING TYPE ❑X NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION [X] NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION METHOD OF LIGHTING 0 COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accur to a d complete. DOCUMENTATION AUTHOR SIGNATURE DATE Deborah ConwayAz-14z'/0- /D -.?i o U The Principal Lighting Designer hereby certifies that the proposed building design represented in this s t of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 - 132, 146, 148 & 149 of Title 24, Part 6. ❑ The plans & specifications meet the requirements of Part 6 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 6 (10-103a 3). ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Busin9ps and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business YyProfessions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER -NAME SI UR DATE LIC. # Rand' Moss .�Z 7-0 1,,E /,3 `1353 LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included ®LTG -1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals ❑LTG -1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed X LTG -1 -C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed DO LTG -2-C: Indoor Lighting Schedule ❑LTG -3-C: Portable Lighting Worksheet ❑LTG -4-C: Lighting Controls Credit Worksheet ®LTG -5-C: Indoor Lighting Power Allowance ❑LTG -6-C: Tailored Method Worksheet ❑LTG -7-C: Room Cavity Ratio Worksheet ❑LTG -8-C: Common Lighting Systems Method Worksheet ❑LTG -9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.2 by EnergySoft User Number: 6429 Job Number: Page:1 of 8 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG - PROJECT NAME DATE Desert Southwest Insurance Brokers 1 10/27/2006 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED WATTS - INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 754 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 754 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑X COMPLETE BUILDING METHOD (From LTG -5-C) ❑ AREA CATEGORY METHOD (From LTG -5-C) ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER ALLOWED WATTS 822 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATIONI (Room #). CONTROL IDENTIFICATION CONTROLTYPE (Auto Time Switch, Dimming, etc.) Check if SPACE CONTROLLED Daylighting NOTE TO FIELD NOTES TO FIELD - For Building Department Use Only EnergyPro 4.2 by Energysoft User Number. 6429 Job Number: Page:2 of 6 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C PROJECT NAME DATE Desert Southwest Insurance Brokers I 10/27/2006 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description r -03 CD -0�•'O 9.33 ym m `� r 3m� pl m a 5'acr �.� m `, ° C.0 9'm 1 y m ,n �m J r c =U=1 fD N w x .... N 4 YeS No 1 (3) 28W T5 F724W/2G11 3 24 1.01 78.0 X 1 8 1 624 2 (2) 26w Compact Fluor. WL 2 26 1.0 55.0 X 1 55 3 70w Surface Mount Inc. ow 1 70 75.0 X 1 75 PAGE TOTAL 754 BUILDING TOTAL (sum of all pages) 754 PORTABLE LIGHTING (From LTG -3-C) D CONTROL CREDIT (From LTG -4-C) O ADJUSTED ACTUAL WATTS 754 EnerovPro 4.2 by EnergySoft User Number: 6429 Job Number: Pace:4 of 6 1 INDOOR LIGHTING POWER ALLOWANCE LTG -5-C PROJECT NAME Desert Southwest Insurance Brokers DATE 10/27/2006 ALLOWgD LIGHTING POI&ERC e COMPLETE BUILDING METHOD - CONDITIONED SPACES ALLOWED WATTS WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From Section 146 Table 146-B) Comp Bldg Office 1.10 747 822 AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF PAGE TOTAL BUILDING TOTAL D D D D AREA WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) O EnergyPro 4.2 by EnergySoft User Number. 6429 Job Number. Page:5 of 6 PAGE TOTAL BUILDING TOTAL D D AREA WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS (From LTG -6-C or from computer run.) D UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section 146 Table 146 -B&C) WATTS PER SF AREA (SF) ALLOWED WATTS PAGE TOTAL BUILDING TOTAL D D D D AREA WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) O EnergyPro 4.2 by EnergySoft User Number. 6429 Job Number. Page:5 of 6 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME DATE Desert Southwest Insurance Brokers 1 10/27/2006 DESCRIPTION Designer Enforcement X❑ §131 (d)l For eve floor, all interior lighting systems shall beequipped with a separate automatic () every � 9 9 Y control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. X] 6131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. X] §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. a§111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. a§131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.2 by EnergySoft User Number: 6429 Job Number. Page:6 of 6