Loading...
BWFE2014-107778-495 CALLE TAMPICO LA C(UINTA, CALIFORNIA 92253 Application Number: BWFE2014-1077 Property Address: 81035 GIACOMO WAY APN: 767780056 Application Description: GARDEN WALL 33 LF Property Zoning: Application Valuation: $891.00 Applicant: LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 41wQ" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT OCT 24 2011 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisi ns of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Pro essions Code, and my License is in full force and effect. License Class: icense No.:728102 D*: 6(9 Z Contract" or: i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt frootheContctor's State License Law for the following reason (Sec. 7031.5, Business as Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Ad VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/22/2014 IOTA GRIFFIN 4675 MACARTHUR CT NO 1550 NEWPORT BEACH, CA 0 Contractor: LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 (949)349-8269 Llc. No.: 728102 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, i I should become subj t to the workers' compensation provisions of Section 37 of the La o I hall forthwith comply witpt.se ovisions. A D�Applicant: WARNING:AILURE O c SECURE WORKERS' COMPENSATION C VERAGE IS U WFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FIN UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITI N TO THE C OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3 LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT:Application.is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and sta laws relating to building construction, and hereby authorize representatives of this ' y o enter th ab mentionerrd pr erty f inspection purposes. Date:/a/`SD Signature (Applicant or�Ayge t): DESCRIPTION FINANCIAL •• ACCOUNT 1• QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA; $1.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $60.91 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for FENCE OR FREESTANDING WALL TOTALS:•• $108.77 $0.00 0• LEGEND PROPERTY LINE AIR CONDITIONING PAD - — — — — — — - PUBLIC UTILITY EASEMENT Q CONCRETE STOOP RIGHT-OF-WAY (R/W) n SIDEYARD GATE WATER MAIN FIRE HYDRANT SEWER MAIN WATER METER GARDEN WALL SEWER LATERAL RETAINING / GARDEN WALL --------------- TOP OF SLOPE TOE OF SLOPE LOT 200 Ie (410") WAY Au 6'/l L LQ LOT 967 pa (40") NOTE:. OIfA90ON5 SHOWN ARE NOTE. PLOT PLANS MAY NOT SHOW WMWT MORD WORMAMN. R07M TO THE TO BUILD(NG.FACE AND NOT TM.E REPORT FOR DIMENWNS. EASEMENTS. AND an*R INFORVATION OF RECORD. ARCMECTURAL POP -OUTS DRY UTILMES ARE NOT SHOWN ON THIS PLAN. MSA CONSULTING, INC UENNAR / OFFM RANCH JULY 2014 MM ID 34M B. Hem Eloy u RAmmo m- - mCk - TRACT Na. - 32879 Tuamm CMM 110-M w FAx 06M 304W - MW Qac*m LOT AREA LOT -279 Way 18.014 SF LENNAR LA OLWA, HIV MADE COUNTY, CAUFO.FHA 980 MONTEUTO DRIVE CORONA CA 92879 SCALE 1'=30' (951) 817-3663 . , I BUYEFrS ACXXfTANM DATE 4`\' Permit Details PERMIT N.U.MBER r City of La Quinta BWFE�2014-1077 Description: GARDEN WALL 33 LF Type: WALL/FENCE Subtype: Status: SUBMITTED Applied: 9/15/2014 MFA Approved: Parcel No: 767780056 Site Address: 81035 GIACOMO WAYLA QUINTA,CA 92253 Subdivision: TR 32879 Block: Lot: 279 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $891.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 33 LF GARDEN WALL [PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES. Process Summary �x Printed: Wednesday, October 22, 2014 4:08:16 PM 1 of 2 0TLT LJ SYSTEMS a oil 411r _, -.:ll - CLTD DESCRIPTION ACCOUNT QTY AMOUNT' PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: Printed: Wednesday, October 22, 2014 4:08:16 PM 1 of 2 0TLT LJ SYSTEMS PC'rl'Ytl�t Det�a1I5 PERMIT NUMBER ;. City of La Quinta BWFE2014-1077 Description: GARDEN WALL 33 LF Type: WALL/FENCE Subtype: Status: SUBMITTED Applied: 9/15/2014 MFA Approved: Parcel No: 767780056 Site Address: 81035 GIACOMO WAY LA QUINTA,CA 92253 Subdivision: TR 32879 Block: Lot: 279 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $891.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 33 LF GARDEN WALL [PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES. IOP. ce ross Summary *K - � a , � � a � a 4 '�� �^ .tR✓ ,. < y �1 my w ,CONDITIONS ..t $ ... w, <.,_.. . t .,- - .*' ."i _ y":. r - ' r . v -s .. d x t• Cab DESCRIPTION ACCOUNT QTY AMOUNT PAID [PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: Printed: Wednesday, October 22, 2014 4:08:16 PM 1 of 2 (JLJ U LJ LJ SYSTEMS 6" (6-0" TO 6-81 PROTO II EXPOSURE C - DIP FOOTING DESIGN CRITERIA (PER 2013 CBC): 1. ALLOWABLE SOIL BEARING PRESSURE PROTO II FENCE WALL = 1000 PSF MIN. 2. ALLOWABLE SOIL PASSIVE PRESSURE = 150 PCF MIN. 3. SEE SHEET B, C, & D PRIOR TO START OF CONSTRUCTION. 6" STD. HOOK „ 6" CAP BLOCK PER SHEET C STEEL PLATE TO BEAR FULLY ON CENTER WEB OR END FACE SHELL - SIZE PER SHEET C. _z 0 U a� N Li J w 0 ZD w o, V'a_ LU x LSI 0 U CLF N C) aa 0 � H J Q W N 0 NO COLD JOINTS-L--- PERMITTED OINTSPERMITTED BETWEEN DIP z AND SETTING PAD 'v HORIZONTAL JOINT C-41 MIN. DEPTH 'D' DIP. FOOTING REINFORCING TOP 2 2'-4" COURSES BELOW PLATE 2'-11" AND AT 24" O.C. BELOW VERTICAL FOOTING REINFORCING AT 6'-8" —POST TENSION (PT) FENCE, USE 1 #4 IN ROD SEE SHEET B FOR CENTER OF DIP ROD SPECS - CENTER IN WALL S 40 5 m /—PROTO II FENCE WALL SETBACK PER crucn /—FINISHED GRADE I I� I I I I I I I I I I I I8. , CONT_,\\ #4 CONTINUOUS AT HOOK z 2 1 MAX CONT. CONCRETE SETTING PAD - SEE SHEET D 3'-0" V 16" MIN FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURS, INSTALL DRAINAGE BLOCK AT SWALE AT GRADE. POST TENSION (PT) ROD SEE SHEET B CONCRETE DIP FOOTING DIP MAY BE OVER EXCAVATED AS SHOWN - FILL WITH COMPACTED FILL OR CONCRETE DIP DEPTH .AT TOP OF 2:1 SLOPE SETBACK — FACE' OF FOOTING .. TO TOP OF SLOPE MIN. DEPTH 'D' DIP. FOOTING 12" TO 36" 2'-4" 6" TO 11" 2'-11" 3" TO 5" 3'-1" FENCE WALL SCHEDULE AT LEVEL SOIL H' DESIGN WIND PT ROD DIP MAX EXP/ PAC -IN --SP -eiN C AT 140 67(o 1- NTA 5'- 0T 6'-0" C AT 1 0 BUILCING & SAFETY DEPT. DAYLIT MIN. CAT 1:10 C' AT 1 0 a Lr-T'--0" .N QT ' -- ROTO II STANDARD Irl—LINE' OF DIP 6'-8N •C AT 1 0 -- - LA QUIN CA FOOTING BEYOND. C AT 120 / 1 fk I I/[ THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE PT P —�— v JOB NUMBER 14-115-9155 G�. 02 � SEALED ON n0 SCO(2 TRACKING # '.DRAWN S 40 5 m 14-115-8964 TMH 0C CE+►RUSo -Paan: g ��_„ PROTO-II TM WALL SYSTEMS GATE ENGR s�R(JCTl1�P c: TURLEY e���� www.PROT02.COM . 08.19.2014 JAC PACKAGE SHEET s'J �P ;:e '.::: SCOTT W�zW�W 41$00 CASCADES COURT TEMECULA. CA 92591 GARY OTTO ,9 %F k� OF � INC. _ =eeeee �o r .ATTN: PH® (951) 694-37,93 - goryoUo®protoii.comA. INSTALLERS) �^� CA1✓ www,CT50Z.COT a... »»» (MAY ONLY 8E INSTALLED 8Y APPROVED AND CERTIFIED 4-. 6". ANO 8" THIO( POSE -TENSIONED MASONRY WALLS S7 THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE GENERAL STRUCTURAL NOTES 1. SOIL SHALL BE FIRM AND COMPACTED PRIOR TO PLACEMENT OF CONCRETE. PRIOR TO FOUNDATION EXCAVATION, USER SHALL VERIFY THAT SITE SOILS CONDITIONS MEET OR EXCEED AN ALLOWABLE PASSIVE BEARING PRESSURE OF 150 PSF/FT (SOIL CLASS 4 OR BETTER AS DEFINED BY THE CBC) STARTING AT THE TOP OF GRADE(I.E. NO TOP SOILS ARE NEGLECTED FOR PASSIVE) AND A MINIMUM ALLOWABLE- BEARING PRESSURE OF 1000 PSF. 2. FOOTINGS TO BE LEVEL. IF GROUND SLOPES THE FOOTING SHALL BE STEPPED. EACH STEP SHOULD BE PROPER HEIGHT TO FIT BLOCK TYPE USED. ALL EXCAVATIONS SHOULD BE CLEAN AND CONTAIN NO LOOSE EARTH OR FOREIGN MATTER. 3. SEE SHEET A FOR EXPOSURE, WIND SPEED, POST TENSIONED ROD SPACING, FOOTING SIZES, ETC. USER IS RESPONSIBLE TO VERIFY REQUIREMENTS WITH BUILDING DEPARTMENT AND OWNER. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE APPROVED SITE PLAN AND APPLICABLE CODE OR JURISDICTION REQUIREMENTS. 4. SOIL BELOW FOUNDATIONS SHALL BE WELL DRAINED AND NON -EXPANSIVE. USE CONCRETE WITH A MIN. STRENGTH OF 2,500 PSI - TYPE II CEMENT (TYPE V WHERE REQUIRED BY OWNER, SOILS ENGINEER OR JURISDICTION). CONCRETE SHALL BE A MIN. OF 48 HOURS OLD PRIOR TO FINAL TENSIONING ALL. ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY SUITABLE MEANS DURING PLACEMENT, 5. LAPREINFORCING STEEL: LAP = 32" FOR #4 BARS IN CONCRETE. 6. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 AND BE 2,000 PSI MIN. (F -M DESIGN CRITERIA FOR BLOCK IS BASED ON 2000 PSI). BLOCK SHALL BE A MIN OF 7 DAYS OLD PRIOR TO ROD TENSIONING. STANDARD HEAD AND BED JOINT BLOCKS WITH MORTAR MAY BE USED OR INTERLOCKING BLOCKS MAY BE USED. BLOCKS SHALL BE LAID IN RUNNING BOND. 7. MORTAR SHALL BE TYPE S. 2000 PSI MIN. MORTAR MUST BE A MIN. OF 4 HOURS OLD PRIOR TO INITIAL' TENSIONING AND 24 HOURS OLD PRIOR TO FINAL TENSIONING. 8. FIRST MASONRY COURSE MAY BE SET IN FRESH CONCRETE FOOTING. 9. REINFORCING REBAR SHALL CONFORM TO ASTM A641; Fy = 60,000 PSI. 10, PROTO-II HARDWARE IS DEFINED AS: TENSION RODS, BEARING PLATES, COUPLERS, NUTS, ALL THREADS, DIRECT TENSION INDICATORS (A DIRECT TENSION INDICATOR (DTI) IS A COMPRESSIBLE WASHER) AND PLASTIC SADDLES. ALL OF THIS HARDWARE SHALL BE SUPPLIED BY ONLY AN APPROVED PROTO-II LICENSEE TO THE CERTIFIED INSTALLER. POST TENSION RODS SHALL BE 7/16" DIAMETER WITH 1/2" ROLL THREADS CONFORMING TO ASTM A641 (FY = 60000 PSI) AND HAVE STEEL CHEMISTRY SO THAT BENDING AND THREADING CAN BE ACCOMPLISHED WITHOUT DAMAGE TO THE POST TENSION ROD. AREA OF POST TENSION ROD = .1503 SQUARE INCHES. BEARING PLATES ARE 1/4" THICK (Fy=50 KSI) SEE SHEET C FOR DIMENSIONS. 1/2" COUPLERS PER ASTM A563 GRADE A. AND THE COUPLER MUST FULLY ENGAGE THE UPPER AND LOWER ROD, FULLY ENGAGED IS DEFINED AS 1/2" MIN. INTO COUPLER. 1/2" NUTS ARE TO BE GRADE 8, PER ASTM A325. 1/2" ALL THREADS PER ASTM A307, GRADE 60. DIRECT TENSION INDICATOR (DTI - COMPRESSIBLE WASHER) IS MANUFACTURED PER ASTM F959. PLASTIC REBAR SADDLES ARE NON-STRUCTURAL. 11. HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER SHEET A AND CONFORM TO ASTM A82 LADDER TYPE, 9 GAGE DIAMETER. LAP JOINT REINFORCING ONE FULL CROSS SQUARE (6" MINIMUM LAP). 12. IN LIEU OF FULL HEIGHT RODS, CONTRACTOR MAY USE SHORTER RODS, 1/2" COUPLERS AND STRAIGHT RODS THREADED BOTH ENDS FOR ADDITIONAL LIFTS. RODS SHALL HAVE A MIN. OF 3" 'L' HOOK, WITH 1/2" NUT AT ENO OF TENSION ROD WHERE EMBEDDED IN FOOTING. 13. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND 20' ON CENTER IN STUCCOED WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. POST TENSION ROD SHALL OCCUR WITHIN 12" OF END OF WALL AND 12" EACH SIDE OF CONTROL JOINT. 14. NO COUPLERS MAY OCCUR DIRECTLY BELOW AND IN CONTACT WITH THE BEARING PLATE. NO BOND BEAM BLOCK MAY BE USED AT PLATE/TENSION LOCATION. 15. TENSION RODS MAY BE STABBED INTO WET CONCRETE OR TIED IN PLACE AT CONTRACTOR OPTION; AT CONTRACTOR OPTION, VERTICAL REBAR MAY BE STABBED DOWN INTO THE DIP. 16. A PROTO-II DTI (COMPRESSIBLE WASHER) SHALL BE INSTALLED AT EVERY TENSION ROD BETWEEN THE BEARING PLATE AND NUT WITH THE DTI "TABS" FACING UP AGAINST THE BOTTOM OF THE NUT. THE SPECIAL DEPUTY INSPECTION REQUIRED AT TIME OF FINAL TENSIONING BY A DEPUTY INSPECTOR SHALL VERIFY FINAL TENSIONING TO 6,000 POUNDS BY 1 OF 2 METHODS; METHOD 1; VISUAL INSPECTION OF DIRECT TENSION INDICATOR (DTI), TABS FACING UP AND COLLAPSED AGAINST NUT WITH NO LIGHT LEAKAGE BETWEEN THE PROTO-II DTI AND BOTTOM OF NUT. METHOD 2: USE OF A CALIBRATED TORQUE WRENCH TORQUED TO 55 FT -LBS. (DTI MUST STILL BE PLACED WITH METHOD 2. NO VISUAL INSPECTION OF DTI REQUIRED WHEN USING METHOD 2). INSPECTOR SHALL OBSERVE THE USE OF THREAD LUBRICANT, THE POSITION OF PLATE ON BLOCK, AND INTEGRITY OF MORTAR JOINTS, AND PROVIDE A SIGNED REPORT TO ALL REQUIRED PARTIES. PROTO II MASONRY DESIGN IS BASED ON THIS SPECIAL INSPECTION. 17. POST TENSION ROD SPACING IS INDEPENDENT OF DIP SPACING. TOLERANCE FOR DIP SPACING IS 112" BUT THE NUMBER OF FOOTINGS MUST REMAIN THE SAME FOR A GIVEN LENGTH OF WALL. PO OD-SPAGa-Nt8" BUT THE NUMBER OF RODS FOR A GIVEN LENGTH OF WALL MUST REMA I 1:HE1 E (�� LA OU f NTA 18. SEISMIC DESIGN CRITERIA: Ss=2.0, S1=0.749 SOIL CLASS=D (ASSUMED) RjrsKEE A G RY I. ,. 19. FOUNDATION INSPECTION PRIOR TO PLACEMENT OF CONCRETE INCLUDE WUp LIO & W04lON•TA� UFAutj-ASIZE/DEPTH AND CLEANLINESS OF FO NDATION. ADDITIONAL SPECIAL INSPECTION A!, REQUIRED ft VY1S iC VE Y n FOR CO�TRUC ICMTO II TANDARD CA F SSD Q , JOB MEIER �O K DATE PT `- o� Z SEALED ON 15-9155 TRACKING !y . DRAWN GI t? 8 19 J¢ f10 COC' S 40 5 m 14-115-8964 TMH w _71J o CARUSO o SAN PROTO-II TIM WALL SYSTEMS WWW.PROT02.COM DATE 08.19.2014 ENGR JAC T9 C TO�P� �* 7URLIEsrRU SCOTT 41800 CASCADES COURT TEMECULA. CA 92591 PACKAGE SHEET C1 T \FOS OF INC. Isg z z ATTN: GARY OTTO ==«« PH® (951) 694-3793 - go,yollostroloii.tor C1 S Q B C A` www.Clsoz.COm i� (MAY ONLY SE INSTALLED BY APPROVED AND CERTMED INSTALLER$I »»» . 6.AND B' THIO( POSE -TENSIONED MASONRY WALLS 1 .2 THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORDS SEAL IS AFFIXED V41H WRITTEN SIGNATURE TOP OF PROTO II WALL (3) (4) 0 ''/ PROTO-II PLAN VIEW 1 X SECTION (8) (7) (5) KEY NOTES: 1. POST TENSION ROD. 2. NUT. 3. DIRECT TENSION INDICATOR (DTI). 4. BEARING TOP PLATE. 5. COLLAPSIBLE TABS. 6. MINIMUM TENSION TO.BE 6,000 LBS LOAD AND CONFIRMED BY ONE OF TWO METHODS PER NOTES "B" & "C" BELOW. 7. FILL CAP BLOCK WITH MORTAR. IMMEDIATELY "FLIP" ONTO ROD. COMPLETELY COVER NUT, ROD AND PLATE WITH MORTAR. 8. CAP BLOCK OF SUFFICIENT SIZE TO COVER PLATE AND ROD. 9. CONTINUOUS HORIZONTAL JOINT REINFORCING. 10. CENTER WEB OR END FACE SHELL BELOW. 11. STEEL PLATE SIZES: A. 4" PROTO II:1/4"x3"x6" B. 4" SLUMP PROTO II:1/4"x2 1/2"x6" C. 6" PROTO 11:1/4"x4 1/2"x6" D. 6" SLUMP PROTO It: 1/4"x4"x6" STEEL PLATES TO BE PLACED AT THE EDGE OF THE CELL SO THAT THE PLATE BEARS FULLY ON, THREE SIDES. 12. DO.NOT USE BOND BEAM BLOCK AT BEARING PLATE LOCATIONS. A. PROTO II OTI TO BE USED AT EACH TENSION ROD. TABS FOR DTI SHOULD 'FACE UP AGAINST BOTTOM OF NUT. TABS WILL COLLAPSE (NO LIGHT PASSES BETWEEN BOTTOM OF NUT AND DTI) WHEN PROPER TORQUE OF NUT HAS BEEN ACHIEVED. B. AS ALTERNATE . TO VISUAL INSPECTION .OF TABS, INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY USE OF A CALIBRATED TORQUE WRENCH. TORQUE NUTS TO 55 FT -LBS. DTI STILL MUST BE PLACED ON ROD IF USING TORQUE WRENCH METHOD. SEE GENERAL NOTE ON SHEET B. C. SPECIAL DEPUTY INSPECTOR WILL PERFORM' A VISUAL INSPECTION WHEN USING THE DTI METHOD TO CONFIRM THE DTI IS COLLAPSED WITH NO LIGHT LEAKS BETWEEN THE TABS AND BOTTOM OF NUT. IF USING TORQUE WRENCH METHOD, DEPUTY INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55 FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED. D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION OF TENSIONING PERFORMED BY ONE OF THE TWO METHODS_ NOTED ABOVE. SPECIAL DEPUTY INSPECTOR TO PROVIDE A COMPI FTFF) R=R4-i9-t6'FE0-1 THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE. FOOTING ELEVATION AT POST TENSION ROD PROTO II FENCE WALL Y I I I II a v �M --- VCONCRETE SETTING PAD THICKENED FOOTING TO PROVIDE 3" MIN. COVER AS REQUIRED \\-7/16- DIA. POST TENSION RODS AROUND ANCHOR BOLT AND NUT (PT) SEE SHEET 8 CENTER.IN X ELEVATION WALL 7/16" DIA. POST TENSION RODS (PT) SEE SHEET 8 CENTER IN WALL 17 I I II �Of z THICKENED FOOTING TO PROVIDE I� 3" MIN. COVER AS REQUIRED AROUND ANCHOR BOLT AND NUT L — — — — — 8.. SECTION Y � CITY OF LA OUNTA BUILDING & SAFETY DEPT. A P ISO. 1STAND 4 FOR CO'IST.R 16100W. CA. /p,T K b �G DATE _ JOB NUMSE Oy SEALED ON 5 h � 8 19 19 / / TRACKING # DRAWN w S 405 m n0 SC 14-115=8964 TMH °G CARUSO o - PROTO-II TM WALL SYSTEMS - DATE ENGR 'rURLEY me WWW.PROT02:COM o' 08.19.2014 JAC PACKAGE SHEET pgp@W@ 41800 CASCADES COURT TEIdECULA. CA 92591 ATTN: GARY OTTO F FCA \ \Fpm INC. eeit3� S. aaos PH# (951) 694-3793 - goryotlo®Proloii.corri'S1.2 INSTALLERS) D www.clsoz.com 6 NN�NNN (MAY ONLY BE INSTALLED BY APPROVED AND CERTIFIED moo 000 A. 6'. AND B' THIP( POST -TENSIONED MASONRY WALLS THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXEO WITH WRITTEN SIGNATURE I PERMIT INSPECTION HISTORY REPORT (BWFE2014-1077) FOR CITY OF LA QUINTA Wall / Fence 09/15/2014Application Date:Permit Type:767780056Parcel Wall / Fence 10/24/2014Work Class:Issue Date:81035 GIACOMO WAY LA QUINTA, CA 92253 Address: Expired 04/22/2015Expiration Date:Status:Description:GARDEN WALL 33 LF *** 33 LF GARDEN WALL [PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES. Owner:Contractor:Applicant:IOTA GRIFFIN LENNAR HOMES OF CALIFORNIA INC LENNAR HOMES OF CALIFORNIA INC Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date 12/23/2014 Footing MFA:14091504450 13256 Approved Kirk Kirkland No Complete 78-495 Calle Tampico Page 1 of 1October 10, 2024