Loading...
14-0631 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 14-00000631 Property Address: 81115 GIACOMO WY APN: 767-320-999-275 -32879 Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 37000 Tihf 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Applicant: Architect or Engineer (or'"A&vk/'Y AAA LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C10 License No.: 881356 Date: Q/ Contractor:Drl/Q,7 6&7,10 Y �J Inc. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: L( PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/18/14 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier HARTFORD FIRE Policy Number 72WECD11884 I certify that, in the performance of the work for which is permit is issued, I shall not employ any person in any manner so as to b ome ject to workers' compensation laws of California, and agree that, if I should be e t the rkers' compensatio provisions of Section 3700 of the Labor Code, I all omp with those prov' ' ns. Date: Applicant: WARNING: FAILURE TO SECURE WORKER OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. .2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation oLwoM for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above' r is co act. I agree to comply with all city and county ordinances and state laws relating to building tr n, an eby authorize representatives of this county to enter upon the above-mentioned property f ins ion es. Date: Q—�/ Signature (Applicant or Age 1: Owner: MICHAUX MICHAEL ANDRE JEAN 81115.GIACOMO WY LA QUINTA, CA 92253 ( Contractor: DRIVEN ELECTRIC, INC. 72078 CORPORATE WAY, STE #104 THOUSAND PALMS, CA 92276 (760)343-3222 / l�o Lic. No.: 881356 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C10 License No.: 881356 Date: Q/ Contractor:Drl/Q,7 6&7,10 Y �J Inc. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: L( PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/18/14 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier HARTFORD FIRE Policy Number 72WECD11884 I certify that, in the performance of the work for which is permit is issued, I shall not employ any person in any manner so as to b ome ject to workers' compensation laws of California, and agree that, if I should be e t the rkers' compensatio provisions of Section 3700 of the Labor Code, I all omp with those prov' ' ns. Date: Applicant: WARNING: FAILURE TO SECURE WORKER OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. .2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation oLwoM for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above' r is co act. I agree to comply with all city and county ordinances and state laws relating to building tr n, an eby authorize representatives of this county to enter upon the above-mentioned property f ins ion es. Date: Q—�/ Signature (Applicant or Age 1: N-, 1� Application Number . . . 14-00000631 Permit . . . ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 23.83 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . 12/15/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 ---------------------------------------------------------------------------- 23.83 Special Notes and Comments 12.2kW SOLAR ARRAY - (47) 260W PHONO PANELS W/ (47) ENPHASE M215 MICRO INVERTERS [800SF) 2013 CALIFORNIA ELECTRICAL CODE. June 18, 2014 3:39:47 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 PLAN CHECK, ELECTRICAL 23.83 PERMIT ISSUANCE M/P/E 90.57 Fee summary Charged Paid Credited - Due --------------------------------------------------------- Permit Fee Total 23.83 .00 .00 23.83 Plan Check Total .00 .00 .00 .00 Other Fee Total 116.40 .00 .00 116.40 Grand Total 140.23 .00 .00 140.23 LQPERMIT Bin. # City. of U. Quinta Buiitiing 8r Safety Division P.O. Box 1504,78-495 Cane Tampico La.Qutnra, CA 92253 - (760) 777-7012 Building Permit Application, and Tracking Sheet Perinit # ProjectAddeess: lU Ownet'sName:. A. P. Number. /� V O�o` - Address: Lege! Description: Contractor. V — 1d, City, ST, Zip: LIA O w n Telephone: ) ' J ' ff ll) Address: V f Y v Sk I Q Project Description: " City, ST, Zip: 4t J�l l l 1" a & 1 O o n Telephone: D .3y 3(A,9 -r 0 '1Jr0 State Lia # : 5 City Lic , Arch, EW., Designer. Address: City., ST, Zip: Telephone: Construction Type: , Occupancy: State Lic. #: Name of Contact Person: Q Y . Project type (circle one): New Add'n Alter Repair Sq. Ft.: # Stories: # Unit,s: Demo Telephone # of Contact Person: ' Estimated Value of Project «� APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Req'd Reed TRACE NG PERMiT FEES Plan Seta Pian Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit. . Trow Calea. Caged Contact Person Plan Check Balance Tide 24 Calci. Plans picked up Construction Flood plain plan Plans resubmitted.*. MechaNeal Grading plan 2'! Review, ready for corrections/ nue Electrical Snbeoatactor List Called Contact Person Plumbing Grant Deed Plans picked up S bLL H.O.A. Approval Plans resabmitted Grading IN HOUSE:- 'i° Review; ready for correetio Developer Impact Fee Planning Approval lb - Called Contact Person ,r A.LP.P- Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees i NOV L m GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION. DO NOT SCALE THE DRAWINGS. THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. IN CASE OF CONFLICT, MORE COSTLY REQUIREMENTS DRIVEN SOLAR GOVERN FOR BIDDING. SUBMIT CLARIFICATION REQUEST PRIOR TO PROCEEDING WITH WORK. CAPTURING ENERGY 1 SAVING MONEY 72078 CORPORATE WAY, SUITE 104 2. ALL DRAWINGS ARE CONSIDERED TO BE A PART OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE THOUSAND PALMS, CA 92276 FOR THE REVIEW AND COORDINATION OF ALL DRAWINGS SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANC P: 760.343.3222 F: 760.343.31 22 THAT OCCUR SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE START OF CONSTRUCTION SO THAT 19 WWW.DRIVEN-SOLAR.COM CLARIFICATION CAN BE ISSUED. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS OR ANY CODE REQUIREMENT SHALL BE CORRECTED BY THE CONTRACTOR AT HIS OWN EXPENSE. CONTRACTOR NAME: Dr(Vf l �OedfiC Ij?C•L d_ CONTRACTOR LICENSE NUM E 61356 (CIO) CONTRACTOR SIGNATURE:_ PROJECT SCOPE: 1. 47 SOLAR PHOTOVOLTAIC MODULES MOUNTED ON THE ROOF AND CONNECTED TO DC/AC ENPHASE MICRO -INVERTERS AND RELATED ELECTRICAL SWITCHGEAR AS REQUIRE BY APPLICABLE CODES AND BY THE ELECTRICAL UTILITY COMPANY. PV SYSTEM INFORMATION: • 47 PHONO SOLAR PS260 MB MODULES (260W) • 47 ENPHASE MICRO -INVERTERS (M215 ® 240) • 11 MODULES ® 18' (ROOF SLOPE) AND 100' SOUTHEAST (AZIMUTH) • 36 MODULES ® 18' (ARRAY TILT) AND 180' SOUTH (AZIMUTH) • PROSOLAR RACKING SYSTEM 3. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING CODES: LOCAL BUILDING CODE, L CODE, AND ANY OTHER REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK, INCLUDINGE NATE OFZ CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, AND THOSE CODES AND STANDARDS LISTED IN THESE NOTES AND SPECI IhTICtNS zoo 4. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT TRANSPORTATION AND SERVICES NECESSAOR-UjF- COMPLETION OF THE WORK. ALL THE MATERIALS AND WORK SHALL BE IN COMPLIANCE WITH ALL APPLICABLE CODES I WOVEWINE REGULATIONS AND SHALL MEET WITH THE APPROVAL OF THE OWNER AND THE STATE FIRE MARSHALL. Q cl 5. NOTIFY OWNER OF SHUTDOWN OF ELECTRICAL SERVICE AT LEAST 5 DAYS IN ADVANCE IF NEEDED. _j cf) er rn Z 6. THE CONTRACTOR SHALL REVIEW EQUIPMENT MANUFACTURER'S REQUIREMENTS AND PROVIDE FUSE SIZES AS IND BI DR tAY CONNECTIONS OR OTHER RELATED WORK TO COMPLETE THE ELECTRICAL SYSTEM. = cc a 7. ALL EQUIPMENT TO BE U.L. LISTED OR EQUIVALENT. U LL 8. PATCH AND PAINT WALLS TO MATCH EXISTING FINISHES. PATCH WALL VINYL IF PRESENT. PATCH AND PAINT ARO DEVISES AND BLANK PLATES IN EXISTING BACK BOX -AS REQUIRED TO MATCH EXISTING FINISHES IF REQUIRED. MAINTAIN ALL RATINGS. 9. CONTRACTORS SHALL NOTIFY THE FACILITY OF TIMES WHEN THE CONSTRUCTION NOISE WILL BE EXCESSIVE. CONTRACTORS SHALL RESCHEDULE SUCH WORK IF SO REQUIRED BY THE CLIENT. I DRIVEN SOLAR CAPTURING ENERGY I SAVING MONEY ;078 CORPORATE WAY, SUITE 104 OrHOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM ;; Iviw MI AUX RESIDEN 81 1 15 GIACOMO WAY LA QUINTA, CA 92253 10. SOLAR PHOTOVOLTAIC SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 690 OF THE NEC AND 2013 CALIFORNIA ELECTRICAL CODE. LEGEND: 11. INVERTERS WILL BE UL 1741 COMPLAINT CEC 690.4D 12. ENPHASE MICRO -INVERTERS WILL BE MOUNTED ON THE RACKING SYSTEM, UNDER SOLAR MODULES PER MANUFACTURE SPECIFICATIONS AND INSTALLATION BEST PRACTICE. 13. MAINTAIN WORKING CLEARANCE AROUND EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT ACCORDANCE WITH CEC 110.26. 14. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN -TIGHT AND APPROVED FOR USE IN WET LOCATION. (CEC 314.15) 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANCE. (CEC 300.6 Cl, 310.8 D) 16. WARNING LABELS SHALL COMPLIANT WITH LOCAL AUTHORITY HAVING JURISDICTION REQUIREMENTS. 17. PV BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. . 18. ALL LOCATION ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Al 19. PROVIDE AND INSTALL NEW CARBON MONOXIDE ALARMS IN ACCORDANCE WITH CALIFORNIA RESIDENTIAL CODE. .I REVISIONS TE No. REVISION NOTE 6/10/2014 1 C.O.LO PIAN REVIEW -I 0 OF BUILDING: SINGLE FAMILY RESIDENCE LE NAME: MICHAUX RESIDENCE a DRAWN BY: JZ ZI DATE DRAWN: 05/08/2014 20. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIE' OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC 690.4(8)) 21. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL. BE INSTALLED ONLY BY , QUALIFIED PERSONNEL. (CEC 690.4(E)). A I DATE VERIFIED: COVER PAGE PV00 TABLE OF CONTENT PAGE NUMBER DESCRIPTION PV_ 1.0 SITE PLAN PV -1.1 PLAN VIEW & DETAIL PV -2.1 RAKING INFORMATION . PV -2.2 RAKING ENGINEERING PV -03 MODULES INFORMATION PV -04 INVERTER INFORMATION E1.1 ELECTRICAL SINGLE LINE E1.2 PV WARNING SIGNS 3. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING CODES: LOCAL BUILDING CODE, L CODE, AND ANY OTHER REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK, INCLUDINGE NATE OFZ CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, AND THOSE CODES AND STANDARDS LISTED IN THESE NOTES AND SPECI IhTICtNS zoo 4. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT TRANSPORTATION AND SERVICES NECESSAOR-UjF- COMPLETION OF THE WORK. ALL THE MATERIALS AND WORK SHALL BE IN COMPLIANCE WITH ALL APPLICABLE CODES I WOVEWINE REGULATIONS AND SHALL MEET WITH THE APPROVAL OF THE OWNER AND THE STATE FIRE MARSHALL. Q cl 5. NOTIFY OWNER OF SHUTDOWN OF ELECTRICAL SERVICE AT LEAST 5 DAYS IN ADVANCE IF NEEDED. _j cf) er rn Z 6. THE CONTRACTOR SHALL REVIEW EQUIPMENT MANUFACTURER'S REQUIREMENTS AND PROVIDE FUSE SIZES AS IND BI DR tAY CONNECTIONS OR OTHER RELATED WORK TO COMPLETE THE ELECTRICAL SYSTEM. = cc a 7. ALL EQUIPMENT TO BE U.L. LISTED OR EQUIVALENT. U LL 8. PATCH AND PAINT WALLS TO MATCH EXISTING FINISHES. PATCH WALL VINYL IF PRESENT. PATCH AND PAINT ARO DEVISES AND BLANK PLATES IN EXISTING BACK BOX -AS REQUIRED TO MATCH EXISTING FINISHES IF REQUIRED. MAINTAIN ALL RATINGS. 9. CONTRACTORS SHALL NOTIFY THE FACILITY OF TIMES WHEN THE CONSTRUCTION NOISE WILL BE EXCESSIVE. CONTRACTORS SHALL RESCHEDULE SUCH WORK IF SO REQUIRED BY THE CLIENT. I DRIVEN SOLAR CAPTURING ENERGY I SAVING MONEY ;078 CORPORATE WAY, SUITE 104 OrHOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM ;; Iviw MI AUX RESIDEN 81 1 15 GIACOMO WAY LA QUINTA, CA 92253 10. SOLAR PHOTOVOLTAIC SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 690 OF THE NEC AND 2013 CALIFORNIA ELECTRICAL CODE. LEGEND: 11. INVERTERS WILL BE UL 1741 COMPLAINT CEC 690.4D 12. ENPHASE MICRO -INVERTERS WILL BE MOUNTED ON THE RACKING SYSTEM, UNDER SOLAR MODULES PER MANUFACTURE SPECIFICATIONS AND INSTALLATION BEST PRACTICE. 13. MAINTAIN WORKING CLEARANCE AROUND EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT ACCORDANCE WITH CEC 110.26. 14. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN -TIGHT AND APPROVED FOR USE IN WET LOCATION. (CEC 314.15) 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANCE. (CEC 300.6 Cl, 310.8 D) 16. WARNING LABELS SHALL COMPLIANT WITH LOCAL AUTHORITY HAVING JURISDICTION REQUIREMENTS. 17. PV BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. . 18. ALL LOCATION ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Al 19. PROVIDE AND INSTALL NEW CARBON MONOXIDE ALARMS IN ACCORDANCE WITH CALIFORNIA RESIDENTIAL CODE. .I REVISIONS TE No. REVISION NOTE 6/10/2014 1 C.O.LO PIAN REVIEW -I 0 OF BUILDING: SINGLE FAMILY RESIDENCE LE NAME: MICHAUX RESIDENCE a DRAWN BY: JZ ZI DATE DRAWN: 05/08/2014 20. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIE' OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC 690.4(8)) 21. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL. BE INSTALLED ONLY BY , QUALIFIED PERSONNEL. (CEC 690.4(E)). A I DATE VERIFIED: COVER PAGE PV00 G I A C 0 M 0 W A Y 10 W BUILDING & SAFETY DEPT IEPOOP FSE® FOR CONSTRUCTION U Z Q o! > F- a z 3 r OVA CONDUIT ROUTED / 1.5' MIN. ABOVE ROOF SURFACE / :ROOF RIDGE _QQF MOOD J -Box �� — — — NEMA 3R TYPICAL (E) CHIMNEY —+ CITY OE I A MIN BUILDING & SAFETY DEPT IEPOOP FSE® FOR CONSTRUCTION DATE BY — — — — — — — — — (E) FENCE (E) VENT (E) GARAGE ROOF (E) 200A MSDP NEW 100A DISCONNECT NEW 1D0A SUBPANEL I NOTES: •, r, f I 01115Caroena Wr/ � ' � 1 s -• x+4ey ry VICINITY MAP 1. SOLAR PHOTOVOLTAIC SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 690 OF THE 2013 CEC. 2. ENPHASE MICRO -INVERTER WILL BE MOUNTED ON THE RACKING SYSTEM, UNDER SOLAR MODULES. I 3. WARNING LABELS SHALL COMPLIANT WITH LOCAL AUTHORITY HAVING JURISDICTION REQUIREMENTS. 4. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC 690.4(8)) 5. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL. (CEC 690.4(E)). A I - - - - - - - - - - - - - --j S ITE. PLAN SCALE 1/16°= 1'-011 I EXISTING MAIN HOUSE ROOF INFORMATION: ONE STORY HOUSE WITH CONCRETE S TILE PV SYSTEM INFORMATION: 47 PHONO SOLAR PS260 MB MODULES (260W) • 47 ENPHASE MICRO -INVERTERS (M215 @ 240) • 11 MODULES ® 18' (ROOF SLOPE) AND 100' SOUTHEAST (AZIMUTH) • 36 MODULES ® 18' (ARRAY TILT) AND 180' SOUTH (AZIMUTH) • PROSOLAR RACKING SYSTEM DRIVEN SOLAR CAPTURING ENERGY I SAVING MONEY 078 CORPORATE WAY, SUITE 104 THOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM MICHAUX RESIDENCE 81 115 GIACOM❑ WAY LA QUINTA, CA 92253 LEGEND: 0 SOLAR MODULE ---- EXISTING FENCE - — - CONDUIT PATH EXISTING PALM TREE REVISIONS GATE No. I REVISION NOTE TYPE OF BUILDING: SINGLE FAMILY RESIDENCE LE NAME: MICHAUX RESIDENCE DRAWN BY: JZ DATE DRANK: 05/08/2014 DATE VERIFIED: SITE PLAN PV 1 .0 ARRAY: DEAD LOAD CALCULATION: • MODULES WEIGHT = 1,969.3LBS • PROSOLAR RAILS, AND HARDWARE = 313 LBS . A/IrRn_IMVFRTFRC WPrWT = 1 SO R I pC NOTES: 1. CONTRACTOR SHALL VERIFY THAT THE EXISTING ROOF STRUCTURE SITE WILL WITHSTAND THE ADDITIONAL WEIGHT. 2 INSTAI I Fn RAKING rOMPONENTS PER MANUFACTURER SPECIFICATIONS. Al P L A N V I E W SCALE 1/8 11 = 11 . 0° 200A MSDP A AC DISCONNECT A SUB -PANEL :MT CONDUfT WITH THWN-2 10 THWN-2 1.25° MIN. ABOVE SURFACE IF LA QUINTA & SAFETY DEPT. ,ROVED INSTRUCTION BY. OP CLAMP 1� SUPPORT RAIL 6' THREADED STUD / \ 'CURVE TILE DRIVEN SOLAR CAPTURING ENERGY 1 SAVING MONEY 2078 CORPORATE WAY, SUITE 104 THOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM MICHAUX RESIDENCE 81 115 GIACOMO WAY LA QUINTA, CA 92253 LEGEND: SOLAR MODULE TILE TRAC ASSEMBLY REVISIONS / DATE No. REVISION NOTE _LAG BOLT EMBEDDED 2.5' MIN. 06/10/2014 All C.O.LO PIAN REVIEW -1 TYPE OF BUILDING: SINGLE FAMILY RESIDENCE LE NAME: MICHAUX RESIDENCE kc H M ENT D ETAI L DRAWN BY. JZ NTS DATE DRAWN: 05/08/2014 DATE VERIFIED: PLAN VIEW PV1 0 1 •Ees#eco �rria ;ar,Gra+ t)t► lb, 4 .lea J1,i0d 16s U %sjgd prrrofe"'sswo- e� J� prloducts. {�tidBS��-.foac iStSyBaaa ANa. OxnardrGA'ti3id33 View mare afro on our web. dib art: wwyv,prasola�r.c�rn T�lleTlrac • Patent #J74fifi 9 . Tile Roof Structural Attachment NEW STAINLESS STEEL TILE FLASh7NG 16 F_fientrd ITrao aila;Nni ct a5m ler as standnnl led rduf o meam wit 00A al.aclr nrnl i?ud loca'iom adj!e;la3ilitit flan occas bIhe Iubt 10&g symos m Iihirr&Aby. 7lerear®jw-c-eacrue 7ilE'T•.aa:' (Pr•flw cant-rav tilrrLci.,m refs, ;rile 16 Kill7�hre aelyd Surd;' r�� (�" l�alA7irrPrre1'r�cJStttd} rurt 9 iT-1114 Benefits of TdeTrac° • Easiestand lowest cost waterproof.tile :roof • Includes Ste-Wess.Steel file flashing and otlachment .Stainless Steel lag bait • C rer 1.5 years of industry preferred single log • Aluminum and Stainless Steel •cam oneam for bo'h design moarimum corrosion resistance and strength • 3d party lob waterproof and 'load tested -'Large roof surface contact area evenly Compressionsealedaturrderiaymewandtop• astributestoad The TilreT roc• Design Structurally attaches to roof rafter and allows the rail attachment stud to be located at th.-e strongest point of the fila (the crown) where water does not flaw. Without TfleTrac' 'With TileTrae w..' g. Hits 00130 Valby rawe S�itdafaa�at6l. x� dehOT" emiult J..r` laof�mem) Rafter Na atvoeidiy, r aa1¢�td ro 6t mbar a lj) lieira c o a, cIssan bly Saeiada —� sttudwadly aaatatlayaatna Rafter cdkwhmd dm the rafter Installation steps for both s -curve areaflat eonerete tile* 4ia' It s=EA a 6-- h O±asn d ike lard 1&-L %p42Sd 16 i9W Ee ml hale— tldsg a'IVeb' ds'J as.4dZgsilt jritll9l,dx1IIib1b4 abig & d t#'Wj �}}a 84:a Sig � Saseb � �Q sRd� fla esy0g' its �z nmd pnl3sses�a I� rr»raalr�:Eh lro 6blEt; trQte�ta�err�lflt�rAte� STF2L�3esra� d±� �7 gest3� aai meq_ � E esm4p ds� h gtxz Sp asEn9 illi Ss* 9 hard ille bg Sat aid rdAn &w# N.aT;4liaeoanddatafaniariaa t smlaaalalA�Soda � @ �aetle � Et�7 eFt1` sm�Fses aid wait de dig kass are &!tJL 92kftg02d! gkSWe•d-diet trwokdj maE4aman�bat dtdinaszi 6bsla I&W pts as de EB a9rra Ss }d'etlu'ala Vr!WdK k&l & h3 bb eeti SMIAllaaatoea *M%mbdatws11br as'nd &--J* aq f 1 1€se a �1ar;� ltii�,«�rer dill flat c S wr d dr -.11 fine, . Slapf'824a1/rma':dtdAS9aidMa tMKVB Mg hS=m?a m1k d.0 fina0 & III%— Sze aaltaz V°b ® www.prosndar.aaam 6d &131 Itch toJnli 1 1 %ptkh5a,6ealsisWdimo&all haid-jos Wgll:00AWasisadleml-,1amseiLdp4a SlaglFin nfrdlk oeid gra heogs3eval-amNdtsal)yLrNIk6m]e&kj 1!dWS dSWd1t'S0;a!!ga::ldm)m 31?�bJtrss��� 4/1>'we2lesaaatrgSce V�Isbldn 6d4'a±1'e 016M"dS! az!_ *NCR tow==&d fav day or dost rases. ®Professional Solar Pro&Lcts, Inc. a'14ae 2.01.1. Tile Crac-is a ne5isrered tradrmark and ea,.wcd under Pat =5,146,029 RACKING INFORMATION ,..� 4 M . DRIVEN SOLAR CAPTURING ENERGY i SAVING MONEY 2078 CORPORATE WAY, SUITE 104 THOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM MICHAUX RESIDENCE 81 115 GIACOMO WAY LA QUINTA, CA 92253 LEGEND: REVISIONS DATEI No. I REVISION NOTE 06/10/2014 1 At I C.O.LO PLAN REVIEW -1 TYPE OF BUILDING: SINGLE FAMILY RESIDENCE LE NAME MICHAUX RESIDENCE DRAWN BY: iz DATE DRAWN: 05/08/2014 DATE VMF1E0: AS NOTED PV2.1 �r VONCI & ASSOCIATES cuExT: Structural Engineers Professional Solar Products, Inc. 1551 S. Rase Ave., Oxnard, CA 93033 Tel: 805486.4T00 Subject Static load test results for the following. Mounting S Maximum Frame Maximum Frame g Y� load Equivalent Wind Speed Length* (in.) Width* On.) (ibs/ft") (Mph)** RoofTrac 0 65 40 50 125 TEST SETUP (as shown In attached drawing : Three modules, as specified above, were bolted to 136"xL5x2.5• Professional Solar Products (PSP) patented Roofrrace support rails using an assembly of 5/16' Stainless Steel (SS) bolts, SS lock washers and proprietary PSP aluminum damps and Inserts. The RoofTrac® support rail was attached to the PSP RoofTrac® structural attachment device with 3/8' SS hardware at four attachment points. The setup was attached to 2"x6" wooden rafters using 5/16"x 31/2" SS lag bolts. The attachment spans consisted of 48' front to rear with structural attachments spaced 72' on center. TEST PROCEDURE (as shown In attached drawing deteip: The test set up was top loaded to 50 lb/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was re -loaded to 50 lb/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.313', with no permanent deformation. The maximum uplift deflection was recorded at 0.250', with no permanent deformation. This document certifies the RoofTracs mounting system used with the modules, as specified above, withstands a 50 Ib/ft2 static pressure load, equivalent to a wind speed of approximately 125 mph**. The mounting system performed as expected. Sincerely, James R. Vinci, S.E. This engineering report verifies that Vinci & Associates has provided Independent observation for load testing as described in this report The results of this load test reflect actual deflection values and are generally ecoepind as the industry standard for testing module mounting systems. Vinci & Associates does not field check installations or verify that the mounting system Is installed as described in this engineering report To assist the building Inspector in verifying the authenticity of--a— this proprietary mounting system, a perms dheslon, silver reflecWe'Rocfrrsc°' label, as shown, is placed on at least one of the main support rails or pemre en stamp with-RoAassiooel Solar Prod. Fat. 6.360.481' on the Roof Trac underside of rail. Structurelattachment: Lag ban attachmentstwuldbeInstalled using the proper pilot hole for optimum strength. A 5/16' leg Por It3 bolt requires a 3/16' pilot hole. It Is the responsibility of the installer to insure a proper attachment is made to the structural member of tine roof. Faille w securely attach to the roof allucture may result In damage to equipment personal Inlury or property damage. This office does not express an opinion as to the lad bearing characteristics of the structure the mountingsystem/modules are being installed on. ICC accredited laboratory tested structural attachments manufactured by Protesslorkal Solar products (including, but not limited to Fastlacke , TIIeTrecv. and Feamlack°) ran be Interchanged with this system. Check with local building department orAW for site specific requirements. *Modules measuring within stated specifications and tested to UL1703, or equivalent are included In this engtneering ••wind loedingvetues relative to defined bad values using wind bad exposure (125 mph 101 5/12 roof pitch or less 100 mph for greater than 5/12 roof pitch) and gust factor coefficient 'exposure C' as defined In the 2008(I8Q/2010(CBC) ••►Module tested: 64.6' x 39.4' x 17'(91n) ••••feat snow bad rating of 25I4?R2 based on 2.0 safety factor Tbousand Oaks#CA 81362 Page 1 of 2 RT—6 Module Area= 18 ft� each Appmx 20' max �— overtone 40" Total module (45 lbs ea.) and rail (12 lbs ea.) weight: 159 lbs so psi 1 1 2,70 psf 1 1 Number of attachments: .4 ea Weight/ attachment point: 40 lbs Area: 54 ft2 Distributed weight: 2.95 Ib/ ft2 5/16" Stainless Steel Hex bolt 5/16' Stainless Steel .---��" Lock Washer 1 � Aluminum ProSolar Inter -Module C4amp Aluminum ProSolar i Rail nut 2-112" Aluminum ProSolar RoofTrac® Support Rail '--� 3/8" Stainless Steel Hex Bolt and Flat Washer 1 Aluminum ProSolar patented FastJack® Roof Attachment' �-- 5/1.6" Stainless Steel Lag Boit and Flat Washer tab tested structural attachments manufactured by Professional Solar Products (Including Festlaclkm . TileTra&. and Famlackv) an be Interchanged with this system. P►ofeaskna/ solar products Rooffise PatenN 6,354491 Photovoltaic mounting system Page 2 of 2 RACKING ENGINEERING Top Load Deflection: 0.313" t 1 2710 lbs / 50 psf V /1 Up lift Deflection: Roof sac® ' Solar Modules Static load test illustration RT—6 E —,A A l i A DRIVEN SOLAR CAPTURING ENERGY I SAVING MONEY 207a CORPORATE WAY, SUITE 104 THOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM MICHAUX RESIDENCE E31 1 15 GIACOMO WAY LA QUINTA, CA 92253 LEGEND: REVISIONS DATE No. I RENSION NOTE 06/10/2014 /Nl C.0.1-0 PLAN REVIEW -1 (TYPE OF BUILDING: SINGLE FAMILY RESIDENCE I IFiIE NAME: MICHAUX RESIDENCE I I DRAWN BY. J2 I IDATE DRAWN: 05/08/2014 1 I DATE VERIFIED: I AS NOTED PV2.2 Pharr®®S®ffar SHARE THE SUN, POWER THE FUTURE: ABOUT PHONO SOLAR Outstanding performance in-PIDAn Phono Solar Technology Co., Ltd. is one of the weak -light conditions world's leading renewable energy product manufacturers and a well trusted bendgivinghigheryieldsin )P68 connetto s enfiante the [helongtenn reltatlility of the PV system �P2'�Excellent temperature coefficient01) Surface Maximum Load Capadry .J"-. Height: 40mm (1.6 Inch) provider. The Phono Solar brand has become 1%4(41.9lbs) synonymous with high performing, top quality I I ® Certified to withstauo Positive current sorting r � photovoltaic panels that are ideal for use in I 1 increased loads of up to 540OPa � l I large scale power plants, commercial and 10 -year product warranty residential installations. IN -0 25 -year performancewarrAntyP1 Maximum System Voltage r--- - - I --- --- - 14.75 Durability assured: �t Salt mist corrosion certification Ammanta COrroYion cei rl`ication 30.0V Fire.test certification Blowing sand resistance certification 37.7V • •II PS25OP-20/U ' _',qtr... ; • ..,.aou1,.' _'. HIGH PERFORMANCE SOLAR MODULES 01-6j"I" J -�IJ1 C EAnk Irma i ®1DOUS p® CEC �® PV LE ® IL ® SUMEC 0 SINGMROI I 5rzitimul No.1 Xinghuo Road, Nanjing HI -tech Zone, Nanjing, China • www.phonosolar.com • info@phonosolancom 235W -265W MECHANICAL CHARACTERISTICS Solar Cella -^, Polyvysta01ne156mm x156mmscuare,6.10piecesinseries!___ operating TemperatureFrom Length: 1640.. (64.6 Inch) oimertilonWidth: 992. (39.1 Inch) Surface Maximum Load Capadry .J"-. Height: 40mm (1.6 Inch) V/el�rt 1%4(41.9lbs) rrom Glass I 3.2mm toughened glass -Frame Anodized aluminium alloy .:Cablo 4mma(IEC)/]I---, 9ppmm---------- --- ------- - ----- ]unction Boa -_ IP 67 rated ELECTRICAL TYPICAL VALUESI4usl ABSOLUTE MAXIMUM RATING Parameter I Values ^' operating TemperatureFrom 40 to.85-C Hail Diameter 080km/h v �U111o2S`nnn ' Surface Maximum Load Capadry .J"-. I Up to 5400Pa 235W _ t Maximum Series Fuse Rating I5A IEC Application Class (IEC61730) A Fire Raring (UL 1703) _...._._._._.._._.....__._._._._...__.._......_._......_._1.. I C ....................... .... ............ 8.06A DC 1000V(IEC) Maximum System Voltage r--- - - I --- --- - 14.75 I DC 600V(UL)/1000V(ETL) ModelRated Pn-(P„r•) Rated Current (6.0 Bated Voltage(V-4 'Short bah Mrent(6) Open t3foit Voltage N.J Mod Ne DOdgr, N P5235P-20N 235W 7.94A 29.6V 8.40A -----i 37.3V w A 14.44 P5240P-20/11 1240W 8.06A 29.8V 8.504, 37.SV 14.75 P5245P-20/1.0 245W 8.18A 30.0V 8.60A 37.7V 15.06 PS25OP-20/U 25OW 8.300. 30.2V 8.70A 37.8V 1537 PS255P-20/U 255W 8.42A 30AV 8.80A 37.9V 15.67 PS26OP-20N 260W 8.530. _-- 30.6V 8.90A -------- 38.OV 15.98 ~ P5265P-20/U 1 265W 8.61A 30.8V 9.00A .7!V 16.29 DIMENSIONS 1640Ida57) I f`bi l:- m inchl `R x: Fhb do sl, et h not leyey pind ft ph.- solar names the'tont to aide w xlff a m change, rl- m,n nor o, Fund, Infpmudw can 1e found on our weWte wwwpbnowC[epm F. Am4PID module tee onh ageade upon rt9ue,t. 2. m mmplunce wM ow wanxay term, and tonmdom. 3. In w Cycle member munutes anal. rte: www.Pncle.ora C Wi-1 as xandard deNarbn or 0--M, meawremema. Ab -i- power values depend - lhe nx In6 Went They can diff, br•/.S%ft" one-Ift-ten, m aneNx. S. tdeaavemm, o damn under kradiance Ie el A SumlaM Test Canditims(SPQ: 1000W/m'. Air mm 1.5 spsmm%caI tanp,at ne of 25'G MODULE INFORMATION TEMPERATURE CHARACTERISTICS I_ V- NOCr(NorpWl opdratim, CaKTemperahre) 45Y32% 1.000 --i 1 VohagoTmtperanaa Coefficient -0.31%/K comm Ter pleattaeccafte t -0.07%/K P. -Te perabtr cm-ent -0.40WK f WEAK LIGHT PERFORMANCE intensity (W/01 I_ V- 2000 1.0 1.000 800 V 0.8 `-- 0.9% 600 0.6 0.990 I1 am OA 0.983 200 0.2 0.952 -___Y -- PACKING CONFIGURATION Container 40' HQ piecesp-pallat --- 24 PA." ter W'dal er 28 Pont perta nalwr _- 672 _J PARTNER INFORMATION AUS -U -P-1312 DRIVEN SOLAR CAPTURING ENERGY 1 SAVING MONEY 1078 CORPORATE WAY, SUITE 104 THOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM MICHAUX RESIDENCE 81 1 1 5 GIACOMO WAY LA QUINTA, CA 92253 I LEGEND: REVISION$ DATE No. I REVISION NOTE 06/10/2014 1 All C.O.LO PLAN REVIEW -1 HYPE OF BUILDING SINGLE FAMILY RESIDENCE I IFILE NAME: MIWM RESIDENCE I I DRAWN BY: JZ DATE DRAWN. 05/08/2014 IItL1►�i��ilil�l INFORMATION PV03' Enphase® Microinverters EnphaseOM215 The Enphase® M215 Microinverter with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all -AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M215 integrates seamlessly with the Engage® Cable, the Envoy' Communications Gateway', and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE Maximizes energy production Minimizes impact of shading, dust, and debris No single point of system failure [e] enphase® E N E R G Y SIMPLE No GEC needed for microinverter No DC design or string calculation required Easy installation with Engage Cable RELIABLE More than 1 million hours of testing and millions of units shipped Industry-leading warranty, up to 25 years SPe c us Enphase®M215 Microinverter // DATA INPUT DATA (DC) M215-60-2LL-S22-IG / S23 -IG / S24 -IG Recommended input power (STC) 190 - 270 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V - 39 V Operating range 16 V - 48 V Min/Max start voltage 22 V / 48 V Max DC short circuit current 15 A Max input current 10A OUTPUT DATA (AC) @208 VAC ®240 VAC Peak output power Rated (continuous) output power Nominal output current Nominal voltage/range Nominal frequency/range Extended frequency range' Power factor 225 W 215 W 1.1 A (A rms at nominal duration) 208 V / 183-229 V 60.0 / 57-61 Hz 57-62.5 Hz >0.95 225 W 215 W 0.9 A (A rms at nominal duration) 240 V / 211-264 V 60.0 / 57-61 Hz 57-62.5 Hz >0.95 Maximum units per 20 A branch circuit 25 (three phase) 17 (single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY 1.6 kg (3.4 lbs) CEC weighted efficiency, 240 VAC 96.5% CEC weighted efficiency, 208 VAC 96.5% Peak inverter efficiency 96.5% Static MPPT efficiency (weighted, reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA The DC circuit meets the requirements for ungrounded PV arrays in Ambient temperature range -40°C to +65°C Dimensions (WxHxD) 163 mm x 173 mm x 25 mm (without mounting bracket) Weight 1.6 kg (3.4 lbs) Cooling Natural convection - No fans Enclosure environmental rating Outdoor - NEMA 6 FEATURES Compatibility Compatible with 60 -cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Ground fault protection (GFP) is integrated into the microinverter. Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, [a ] enphase® visit enphase.com E N E R G Y O 2014 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. INVERTER INFORMATION DRIVEN SOLAR CAPTURING ENERGY I SAVING MONEY 2078 CORPORATE WAY, SUITE 104 THOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM MICHAUX RESIDENCE 81 1 15 GIACOMO WAY LA QUINTA, CA 92253 LEGEND: REVISIONS DATE I No. REVISION NOTE TYPE OF BUILDING: SINGLE FAMILY RESIDENCE tF NAME MICHAUX RESIDENCE DRAWN BY: JZ DATE DRAWN: 05/08/2014 DATE VERIFIED: INFORMATION PV04 PHOTOVOLTAIC SYSTEM NOTES: ' 1. THE PHOTOVOLTAIC INSTALLATION SHALL BE IN ACCORDANCE WITH THE 2013 EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC) ARTICLE 690 AND 250, AND LOCAL ELECTRICAL CODES CURRENTLY BEING ENFORCED BY THE AUTHORITY HAVING JURISDICTION (AHJ) t 2.A GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE INVERTER IN ACCORDANCE WITH NEC/CEC 690.5(A) 3.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED CODED GREEN (OR MARKED GREEN IF #4 AWG IOR GREATER) 4.WIRE SIZES AND CALCULATED VALUES ARE NOMINAL AND SHOULD BE VERIFIED OR RECALCULATED BASED ON FIELD INSTALLATIONS AND MEASURED CONDUIT RUN IN ACCORDANCE WITH ARTICLE 310 OF THE NEC AND CEC 2013 5.MARKINGS OF THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS SHALL BE PROVIDED IN ACCORDANCE WITH NEC/CEC 690.17. &MARKING OF THE DIRECT CURRENT PHOTOVOLTAIC POWER SOURCE SHALL BE PROVIDED IN ACCORDANCE WITH NEC/CEC 690.53. 7.MARKING OF THE INTERACTIVE SYSTEM POINT OF CONNECTION SHALL BE PROVIDED IN ACCORDANCE WITH NEC/CEC 690.54. &CONTRACTOR SHALL SEAL ALL PENETRATIONS/CORE DRILLS THROUGH WALLS AND FLOORS WITH FIRE RETARDANT MATERIALS. ALL PENETRATIONS TO BE SEALED AND PATCHED ACCORDINGLY 9.ALL ELECTRICAL PANEL—BOARDS ARE TO BE 600V AC RATED, NEMA 3R IN STAINLESS STEEL ENCLOSURES WITH SWING OPEN DOORS AND LOCKABLE COVERS. 10. USE UL APPROVED BONDING FITTINGS AT ALL CONDUIT/BOXES JUNCTIONS. 1 1. USE CONDUIT SIZES THAT SATISFY REQUIREMENTS PER CHAPTER 9, TABLE 1.0, ANNEX C (TABLE C.1), OF THE CEC. LARGER DIAMETER CONDUIT MAY BE USED TO . FACILITATE EASE OF IN 12. USE ENPHASE MICROINVERTERS WITH INTEGRATED GROUND. BRANCH CIRCUIT (B.C) 91: MAX.HONOBC CU SOLAR (260W)DC MA. BC CURRENT = � (0.9Ax16)(1.25) - 18A MAX. < H f BRANCH CIRCUIT (B.C) 1 2: MAX.8C CU SOLAR (280W) DC MA, BC CURRENT = AC (0.9A,00)(1.25) - 11.25A MAX. < H / BRANCH CIRCUIT (B.C) 93: MAX.BC CU SOLAR (2801) oc MA. BC CURRENT = AC (0.9Ax10)(1.25) - 11.25A MAX. < H / 11 M215 BRANCH CIRCUIT04: (11) PHONO (2 SOLAR (280W) 7AC� MAX. BC CURRENT = (0.9Ax11)(1.25) = 13.75A MAX. PHONO SOLAR PS260MB 26OW MODULE RATING @STC MAX POWER CURRRENT imp 8.53A MAX POWER VOLTAGE VmP 30.6V OPEN -CIRCUIT VOLTAGE Voc 38V SHORT-CIRCUIT CURRENT Isc 8.9A MAX POWER Pmox 26OW MAX SYSTEM VOLTAGE UL 600VDC MAX. SERIES FUSES RATING ROOF MOUNTED 15A OPERATING TEMPERATURE FROM -40' TO +85C ENPHASE MICRD-INVERTER M215 (240) RATING @ STC MAX DC VOLTAGE 48V MAX POWER DC 270W PEAK OUTPUT POWER AC 225W MAX AC CURRENT 0.9A VM PT MAX 48V VM PT MIN 22V OC MAX. INPUT CURRENT 15A WEATHER PROOF �Iffg OF DRIVEN SOLAR CITY OF LA QUINTA CAPTURING ENERGY I SAVING MONEY BUILDING & SAFETY DE 72CORPORATE WAY, SUITE 104 PT. THOUSAND PALMS, CA 92276 AD P: 760.343.3222 F: 760.343.3122 FOR CONSTRUCTION WWW.DRIVEN-SOLAR.COM DATE BY_ /— JUNTION BOX NEMA 3R ROOF MOUNTED 4 # 10 (U. L2. N &G) THWN-2 IN Yi' EMT CONDUIT 1 NEW 1250. 120/240V 14 SIB -PANEL SIM OF OCPO= 2DA+tsA+15a+15A+soA = 125A PANEL 1205 = 125A x 1.2 - 150A > 125A OK PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS SHALL BE PERMANENTLY MARKED CEC 690.14 C2 AND NEM 6.3 "PHOTOVOLTAIC DISCONNECT FOR WARNING DUAL POWER SUPPLY PHOTOVOLTAIC SYSTEM MAXIMUM AC CURRENT: 54.16A OPERATING VOLTAGE: 240V ��Y NUMBER OF MODULES PER INVERTER M47US WEAJUNERPR sox WEATHER PROOF JUNnON BOX TOTAL NUMBER OF BRANCH CIRCUITS UTILITY OPERATION" NUMBER OF 20A SOLAR BREAKERS CIRCUIT BREAKER NEMA 3R GROUND BONDING NEMA 3R ROOF MOUNTED 1.25" EMT CONDUIT TYP. ROOF MOUNTEDMICHAUX RESIDENCE 3 8 11, L2, N + 1 I 10 G. 2P LABEL. INSTALLED AT THE 8 10 (LI, L2, N &G) NEW SIB -PANEL AND AC DISCONNECT (MEETER THWN-2 (CEC 690,541 81 1 15 G I A C O M O WAY IN X" EMT CONDUIT 4 # 10 L1, L2, N & G 1 2P WARNING DUAL POWER SUPPLY LA Q U 1 NTA, CA 92253 PHOTOVOLTAIC SYSTEM T(E) WEATHER PROOF JUEMA BOX MAXIMUM AC CURRENT: 42.3A15D AMP NEMA 3R � 4 10 Lt, L2, N & G 1 2P OPERATING VOLTAGE: 240V BREAKER ROOF MOUNTED AC DCCT n CUTLER HAMMER 4 0 10 (LI, L2, N &G) THWN-2 ARRAY SUMMARY TOTAL NUMBER OF MODULES 38VX1.14=43.32V NUMBER OF MODULES PER BRANCH CIRCUIT NUMBER OF MODULES PER INVERTER M47US NUMBER OF INVERTERS TOTAL NUMBER OF BRANCH CIRCUITS NUMBER OF 20A SOLAR BREAKERS TYPICAL 16 MODULES BRANCH CIRCUIT MAX Voc 38VX1.14=43.32V MAX Isc 8.901.25=11.12A BRANCH CIRCUIT CURRENT 0.9A X 16 = 14.4A MAX. BRANCH CIRCUIT CURRENT 14.4A X 1.25 = 18A 100A / 240V AC DISCONNECT 3#6(LT.L2&N) I # 6 GRD. THHN OR THWN IN 1.5" EMT CONDUIT gm A. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. (CEC 690.4(B)) B. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL. (CEC 690.4(E)). ELECTRICAL ONE LINE ?� EXISTING 200A MSOP CUTILER HAMNER N LOAD (E) GROUNDING SYSTEM THIS LABEL SHALL BE INSTALLED AT THE MAIN ELECTRICAL SERVICE (CEC 705.10) " THIS SERVICE ALSO SERVED BY A PHOTOVOLTAIC SYSTEM" WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS (CEC 690.17) "WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION LEGEND: GROUNDING CONDUCTOR A PV MODULES STRING INVERTER UNIT �- DISCONNET FUSE CIRCUIT BREAKER GROUND BONDING REVISIONS DATE No. I REVISION NOTE 06/10/2014 1 All C.O.LO PLAN REVIEW -1 TYPE OF BUILDING: SINGLE FAMILY RESIDENCE LE NAME MICHAUX RESIDENCE DRAWN BY: JZ DATE DRAWN: 05/08/2014 DATE VERIAM: ONE LINE E 1. 1 WARNING ELECTRLC SHOCK HAZARD {F A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCT©RS MAY BE UNGROUNDED AND ENERGIZED 690.5(C) - INVERTER WARNING INVERTER OUTPUT C►ONNECTION DO NOT RELOCATE THIS OVERCURRENT IDEVICE 705.12(D)(7) - PANELBOARD WARNING: FHOTOUOLATIC POWER --a - . CEC 690.31(E)(3) AND CFC 605.11.1.2 - DC CIRCUITS, JBOXES, ETC. WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS.. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. RATED AG OUT?UT CURRENT 42.3 A NOMINAL OPERATING AC VOLTAGE Z4O V 690.17/690.54 - AC DISCONNECT N/A AC CIRCUIT WARNING E CTRfC SHOCK4 WZ,A- DON • T TOUCH TER ALS. TERM I , LS ON B H THE LINE AND ■ AD -•IDES MAY BE ENERGIZE IN THE OPEN RATED lvlpp URRENT RATED p VOLTAGE MMIS - SIEMVOLTAGE ORT CIRCUIT CURRENT 690.17/690.53 DC DISCONNECT WARNING THIS SERVIC►E IS SUPPLIED FROM MULITPLE SOURCES: UTILITY AND PHOTUOLTAIC 690.56(8)/705.10 - SERVICE WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM UNGROUNDED AND MAY BE ENERGIZED 690.35(F) - UNGROUNDED DC CIRCUITS PV WARNING SIGNS Q I CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY ' 1 ' DRIVEN SOLAR CAPTURING ENERGY I SAVING MONEY 72078 CORPORATE WAY, SUITE 104 THOUSAND PALMS, CA 92276 P: 760.343.3222 F: 760.343.31 22 WWW.DRIVEN-SOLAR.COM MICHAUX RESIDENCE 81 1 15 GIACOMO WAY LA QUINTA, CA 92253 LEGEND: REVISIONS DATE No. I REVISION NOTE 06/10/2014 1 Al C.o.Lo PLAN REVIEW -1 TYPE OF BUILDING: SINGLE FAMILY RESIDENCE LE NAME MICHAUX RESIDENCE DRAWN BY: JZ DATE DRAWN: 06/10/2014 DATE VERIFIED AS NOTE E 1. 2