Loading...
04-5209 (SFD)Ti4f 4 4 Q" O ox'15�04�! E' 9 ¢. 78-4�95�CALLE,TAMPICO ,,,,.LA QUTNTA, `CAi IFORNIA 92253 BUILDING PERMIT Application Number . . . . . Property Address APN: Application description . . . Property Zoning . . . . . . . Application valuation . . . . Owner SHEA LA QUINTA C/O JEFF MCQUEEN 8800 N GAINEY CENTER 350 SCOTTSDALE. AZ 85258 BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 z�0-4=0-0-0:05_249—' Date 6/29/..04 8-1285 GOLDEN BARREL WY 764-270-999-85 -300233- DWELLING - SINGLE FAMILY DETACHED MEDIUM HIGH DENSITY RES 146209 Contractor SHEA HOMES, INC. 81260 AVENUE 62 LA QUINTA CA 92253 (760) 777-6005 Qty Unit Charge Per. Extension WCC: NTL'UNION INS WC: 7165833 08/01/04 CSLB: 672285 06/30/05 CCC: B -------------------------- Structure Information ------------------------- Construction Type . ... . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC. FIRE SPRINKLERS NO GARAGE SQ FTG 488.00 PATIO S.Q`FTG 177.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 1662.00 ---------------------------------------------------------------------------- Permit . . . .BUILDING PERMIT Additional desc Permit Fee 804.00 Plan Check Fee 522.60 Issue Date . . . . Valuation . . . . 146209 Qty Unit Charge Per Extension BASE FEE 639.50 47.00 3.5000 THOU BLDG 100,001-500,000 164.50 -------------------------------------------- Permit . . . . ... --------------------------------- MECHANICAL Additional desc . . Permit Fee 64.00 Plan Check Fee 16.00 Issue Date . . . . Valuation 0 Qty Unit Charge Per. Extension P.O. BOX 1504ICE VOICE (760) 777-7012 75-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING cit SAFETY DEPARTMENT JI Application Number: Applicant: 0 y- 5a0 Applicant's Mailing Address: VP Date: chir)T1P@i70,h ArchitecttorrEnngineer's Address: 'r( ,4—tic. No.: tC7 2IPya' BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm and�Q enalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and.my Lice bati in full force and effect. icenseClafs(s I/ � n'--�ic-e�n(se(.L/ No. /Oy Dat �`� Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec.._, BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I ave d II maintain orkers compensation i sure as regwrmd by Section 3900 of the Labor Code, for the performance of the work for which this permit is ssue . workers' mpensation ins ce cam 1VnVare�• �arierN icy Number �+ _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall fNxo with comply with thosep ovisions. �e � V pplica t WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being perforned under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if wo is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I gree to comply with all city and county ordinances and state laws relating t building constructi , and ereby authorize representatives of this coun r upon a ntioned properly for inspection purposes. Dat ` O ignature (Applicant or Agen Page 2 Application Number .. . . . . 04-00005209 Date 6/29/04 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 1.00 6.5000 EA MECH VENT FAN 6.50 1.00 6.5000'EA , MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 82.93 Plan Check Fee 20.73 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1662.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 58.17 488.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 9.76 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc . . Permit Fee . . . . 128.25 Plan Check Fee 32.06 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extsension BASE FEE 15.00 10.00 6.0000 EA PLB FIXTURE 60.00 1.00 15.0000, EA' PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9..00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit . . ... . . GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 85, PLAN 4520A, 1662 S.F 9 N Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 1094.18 Page 3 Application Number . . . . ' . 04-00005209 Date 6/29/04 ---------------------------------------------------------------------------- Special Notes and Comments .00 PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPRO e ACH ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00. ENERGY REVIEW FEE 52.26 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 ' DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 14.62 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 1094.18 .00 591.39 .00 2471.88 .00 4157.45 .00 Credited. Due .00 1094.18 .00., 591.39 .00 2471.88 .00 4157.45 01/18/2005 ';08:35 17603401819 INSULATION CERTIFICATE This is to certily that insulation has been installed in conformance with the current energy regulati:>n, California Administrative Code, Title 24, State of California, in the', building at 81-285 GOLDEN BARREL -WAY, LOT 3085, PHASE 7B, LA QUINTA CA CEILIP, TYPE: 3LOW MANUFACTURER: Certainteed THICKNESS: R-38 WALL,; TYPE: SLOW MANUFACTURER: Certainteed THICKNESS: R-13 GENET: AL CONTRACTOR: SHEA HOMES LICENSE # BY: TITLE: PARAc: SON SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 BY: G!� TITLE: ACCOUNT REPRESENTIVE DATE: �U INSULATION CERTIFICATE This is 1.:be4jify that insulation has been installed in conformance with the current ever regulatii: n, Ca rnia Administrative Code, Title 24, State of California, in the bui oca CEILINi: S: TYPE: I; _OW MAUNFAC ER: Ce eed THICKNESS.: R-38 WALLS.- TYPE: ALLS:TYPE: BATTE; M FACTURER: Certaint THICKNESS: R-13 GENERAL CO ACTOR: LICENSE # BY:� ;/ TITLE: PARAi: SON SCHMID BUILDING PRODUCTS A MASCO Company LICE E # 221517 13Y: TITLE: ACCOUNT REPRESENTIVE D<�TE: PAGE 09/37 i Installation Certificate: Residential CF -6R Site Address 81-285 Golden Barrel Way, 1- BUILDER INFORMATION Shea Homes - Trilogy - LaQuinta 81260 Ave. 62 La Quinta, CA 92253 INSTALLING CONTRACTOR: 2. PROJECT INFORMATION DISTRIBUTION_ TYPE Flexible Ductwork in Attic and Between Floors DUCT ORt PIPING R- YALUE Flexible Ductwork Will have a R -Value of 4.2 or Better PERMIT # SUBDIVISION: Trilogy (� La Quinta CITY: La Quinta COUNTY: Riverside WEST P_,- C AIR CONDITIONING 1, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the rcquirements of the Appliance Efficiency Standards. In. addition, Ihave verified that the equipment is equivalent to or more efficient than the equipment specified or the Certificate of Comphance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. 3. IIEATING INFORMATION HEATING MANUFA.CT HEATING UNIT ACTUAL EFF, HEATING EQUIP HEATING EQUIP. MAKE MODEL # AFUE CAPACITY LOAD Furnace Lennox (340 1440-090X 80% 88000 4. COOLING INFORMATION COOLING MANUFACT COMPRESSOR ACTUAL EFF. COOLING EQUIP COOLING EQUIP. MAKE MODEL # SEER CAPACITY LOAD A/C .Lennox 13ACC-048 12 The building design heat .loss and design heat gain rate have been determined using a method specified in Section 1.5001) of the Energy Efficiency Standards, and are two of the criteria used for equipment sizing and selection. 6.THERMOSTATIC EXPANSION VALVE (TXV): Thermostatic Expansion Valve (or Cornmision approved equivalent) is installed and access is provided for inspection. Yes[, No N/A l.___j 6. SUBMITTED BY '4 DATE: Signature Installing HVAC Contractor JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 L=8A INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 11/14/04 Project: Trilogy @ La Quinta - Shea Homes 81-260 Avenue 62 La Quinta, CA 92274 Project No: 02-1109 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A Phase 7B - Lot # 3085 Slab on Grade 9-13-04 Concrete 273,949 Kitchen Required psi: 4000 7647 7 3010 8 I 6N 64 M- 7648 28 4350 - r 7649 28 430 CERTIFIED: Page 1 of 1 ICU Inspections supplies the service of compression strength test results only. Per ASTMC39 I-. :..i Ku' JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 81-260 Avenue 62 La Quinta, CA �✓ IBC Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips S14mpsi to 33.04 kips/33,000 lbs Calibration Date: Machine # So Ci - 23 -cat) Phase .2, Lot# Product 1 Plan ag5 Weather: S�,n�, Unresolved Ite s: N None See Below Description of Work Inspected: Specified Lot # Location Tendons Elongation (in) Actual Elongation (in) 1 C. h rr 1 i �.S W A\ 1 r%_7 (� , t 0rr(" t"'.Qq al+an c, i i ( (, I j oar -�- 8—Sty\ \'RA<\V-C '�QAf G c r ccr, (Z C)O XL I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Ja C. Millin ICC Corti is tion oi�0842216-89 Contr cto epresentative: V Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page _J of _�___ L==�Lm INSPECTIONS JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Date: 9_19_0q Project Name: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 Project Address: 81-260 Avenue 62 City: La Quinta, CA Title 24 File # App# AWS [✓ UBC ,Other: ❑ D 1.1 ❑ D 1.4 ❑ Other Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Shea Homes Architect: Bassenian Lagoni Structural Engineer: Borm & Assoc, Inc/Suncoast Post Tension LP Slump (inches): Time Sampled: Time in Mixer (min.): Water Added @ Jobsite (gals.): Concrete Temperature (F): Ambient Air Temperature (F): Supplier: Mix Design: Specified Strength (PSI): Addmixture: Truck #: Field ID Marking: Ticket #: Weather: Unresolve ms: LAP None See Below Location ofSample:g0 «c r rk 1u�c.�n +r' t _AJ`` , 1' n a a. .� c.. ..r t A, r No Samples Taken Description of Work Inspected: n •� ,;"'3oR r n 1- C_ A !.�_ \ h�!'atr r n lh b. w _ 1!`. c' w A. _ \ rl`h� ' i . c� fl v� 13 M d n V -)D I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: Jack Q. Millin ICC Certificatio `No40842 tor"s �i Cont p s216-80 ative: u Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page of JCM Inspections Effi 39725 Garand Lane Suite F ttK mDesert, CA 922,11 ^hdn"e: INSPECTIONS PLL 756:0-34'5-5554 -. Fax: 760-772-3895 INSPECTIONS . ti REINFORCED CON CRETEs4WSPECTION REPORT Date: Project Name: " Project No: Trilogy @ La Quinta - Shea Ho ,- ; 02-1109 Project Address: City: �• ❑Title 24 AWS ❑✓ UBC Other: 81-260 Avenue 62 La Quinta, CA File # ❑ D 1.1 App# ❑ D 1.4 Client: Sub -Contractor: ; Shea La Quinta, LLC DCCCC 0 ❑Other General Contractor: Architect: r°Y Structural Engineer: Shea Homes Bassenian Lagoni .#f Borm & Assoc, Inc/Suncoast Post Tension LP 4 �• 1 Slump (inches): tSupplier:�j Weather: Time Sampled: �'.-ZDawl 'Mix Design: .�e Time in Mixer (min.): 1,�` L Specified Strength (PSI): 14Unresolve terns: Water Added @ Jobsite (gals.): �r " Addmixture: M=,3aa `rr Concrete Temperature F : Truck #: Ticket #: p () � 'i / y, _17at0_%1D None Ambient Air _Temperature (F): e:;�g Field ID Marking:S4 N _ 4 \, ❑ See Below Location of Sample, 'w-5+ ❑ No Samples Taken Description Work Inspected: of GcP -1c -A-& nr A Ce��e n G - GX _ f1e`^ CNA La.r afns CA,.'e, t1"' Om'`� /'�`Q� ` t 0--nr.+ F i(5C"�n c t r n�� `. 1 a b o l�- c% rf �lC.o n (v�Y C Q�iA 1 _re ' $►"� GA . t� �7 Quo P li. r . Cc no tt uV VS\a ( t:., nc .. t1' t inc."1: bPe�mc 3i. C�t1o�- tiRt,�ca-z e5. 0C^ re�r�1 \��r. �eQ�l % ar r+ O�sC CC.� sae r -0� r be•e0�v CID ns cnTc al,x F..,-, teSStc�,� e < < ��� oan d c one1A i r) r% 0 %A ce r Y r I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to c6 ply with the approved plans, specifications applicable building laws. Final report issued at project completion. \, Inspector: Jack C. Mill ICC Ce if`ilca i n� oo: 0;842216-80 Conte e esentative: . C *.✓ Copy 1 JCM Inspections Copy 2 Project Superintendent v W Copy 3 Governing Agency Page of Copy 1 JCM Inspections Copy 2 Project Superintendent 61 Copy 3 Governing Agency Page __j of ►S JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Date: o -O Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: I 81-260 Avenue 62 City: La Quinta, CA ZIBC Title 24 Client: Sub -Contractor: Shea La Quinta, LLC DCCCC Other: General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc, I nc/Suncoast Post Tension LP Slump (inches): Supplier: Weather: Time Sampled: Time in Mixer (min.): Mix Design: Specified Strength (PSI): Sun Unresolved Item Water Added @ Jobsite (gals.): Concrete Temperature (F): Addmixture: Truck #: Ticket #: ® None Ambient Air Temperature (F): Field ID Marking: See Below Location of Sample: No Samples Taken Description of Work Inspected: o-4 30 W� 1Q !?l1��1 ► txk AA1*Q0 VZAVJi t,ti lQ to Y - , i l a1 �Ne Q� C t : ., cw G` ts. n ea' � � v g''. 1 ' 3ll 'c A' \] n 3 _ All 09 A.�. Bp,,,s A ell ' C vi"Ll C" /J.7 ;C1_% A A !T f- a) C�ihc_\e_n� V .•c•neko OCQrw c,nJPrce-ctm— S o fcex , izo at- N Ten M111' ��e Q � C.t.t �, f•. c.� �`(S Le. � C. dll � b.�. 'QQ C \ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jac C. Millin ICC Ce 'fic 4ii No:`0842216-80 Cont ctoe Be resen t1ve: Ct•.. � � J r Copy 1 JCM Inspections Copy 2 Project Superintendent 61 Copy 3 Governing Agency Page __j of ►S