Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-1025 (AR)
x P.O. BOX 1504 . 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T_&(f 4 4 a" Application Number: 13-00001025 Property Address: 81275 GOLF VIEW DR APN: 762-390-029- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 20000 Applicant- Architect o Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: WEINER EDW 81-275 GOLF LA QUINTA, Contractor: D & R REPAIR VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 ARn1.A VI CA �P[ AN2ku CITY OF LA QUINTA FINANCE DEPT. 44630 FRANKLIN CT LA QUINTA, CA 92253 (760)218-6414 Lic. No.: 903943 Date: 1/21/14 ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: J3 License No.: 903943 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Date: Contracto _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor . Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 905829 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 700 f the Labor Code, I s Ifo ' h com I with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by / / any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date Applicant: . (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.)• Lender's Name: _ Lender's Address: LQPERMIT APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this c my ent upon the above-mentioned prop inspec s. Dat�ignature (Applicant orAg Application Number . . . . . 13-00001025 Permit . . . ROOM ADDITION 2013 23.83 Additional desc . . Additional desc . Permit Fee . . . . 23.84 Plan Check Fee Permit Fee . . . . 181.61 Plan Check Fee .00 Issue Date . . . . 1.00 11.9200•EA MECH APPL REP/ALT Valuation . . . . 0 Expiration Date . .. 7/15/14 Additional desc'. Qty Unit Charge Per . 0 Extension 1.00 120.1200 LS MISC ROOM ADDN, 1ST 100 SF 120.12 1.00 ---------------------------------------------------------------------------- 61.4900 EA MISC ROOM ADDN, ADDL 500 SF 61.49 Permit PATIO OVERANG & KITCHEN REMODEL. EXT. ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 23.83 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Dale . . 7/15/12 Qty Unit Charge Per -Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20 ---------------------------------------------------------------------------- 23.83 Permit MECHANICAL 2013 Additional desc . Permit Fee . . . . 23.84 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 7/15/14 Qty Unit Charge Per Extension 1.00 11.9200•EA MECH APPL REP/ALT 11.92 1.00 11.9200 EA MECH EXHAUST HOOD ---------------------------------------------------------------------------- 11.92 Permit . . . PLUMBING 2013 Additional desc'. Permit Fee . . . . 35.76 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 7/15/14 Qty Unit Charge Per Extension 2.00 11.9200 EA PLBG FIXTURE/TRAP 23.84 1.00 11.9200 EA PLBG WATER INST/ALT/REP 11.92 ----------------------------------------------------------------------------- Special Notes and Comments ADDITION OF 245 SQ. FT. UNDER EXISTING PATIO OVERANG & KITCHEN REMODEL. EXT. BBQ NOT INCLUDED IN THIS PERMIT October 9, 2013 9:22:14 AM jjohnson. LQPERMIT Application Number . . . 13-00001025 ---------------------------------------------------------------------------- Other Fees . . . . . . BLDG STDS ADMIN (SB1473) 1.00 HOURLY PLAN CHECK 227.50 PLAN CHECK, ELECTRICAL 23.83 PLAN CHECK, ROOM ADDITION 185.90 PLAN CHECK, MECHANICAL 9.54 PLAN CHECK, PLUMBING 35.76 STRONG MOTION (SMI) - RES 2.00 Fee summary Charged Paid Credited Due ---------'-------- Permit Fee Total ---------- 265.04 ---------- .00 -------------------- .00 265.04 Plan Check Total .00 .00 .00 .00' Other Fee Total 485.53 .00 .00 485.53 Grand Total 750.57 .00 .00 750.57 LQPERMIT Bin # T&AIJ City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: g 07E UI -EW Owner's Name: WFE1��../�� A. P. Number: Address: Z7S G�fOL V (% Legal Description: City, ST, Zip: LA Qu t &A TA CA Contractor: V G Tele hone: Address: 3•Q F� L o cl- Project Description: , City, ST, Zip: � 0 A C a� ?-� t T700 Telephone: State Lic. #: CityLic. #.:. ©V (C—(TG W Designer: f L313 Address: -7%— 6'aZ cf�Ten-f acX s City., ST, Zip: F" 7�� 2�f �TelePhone.� State ic. #: :>;;::.<.:;:.;:<:<;.><;;>:.;;>;;;:;::.:>>;>;;•;:<.�.;::::Con tr cti n Type: Occupancy: . Project type one • New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: Z�5 # Stories: # Units: Telephone # of Contact Person:Estimated Value of Project: ZQ QpQ o0 APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready f corrections L Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 21" Review, ready for correctio s/issue O Electrical Subcontactor List Called Contact Person Plumbin `,l AV Grant Deed Plans picked up S.M.I. U /z _ H.O.A. Approval Plans resubmitted Grading & IN HOUSE: '"' Review, ready for corrections/issue Dcvel act Fee (�N Planning Approval Called Contact Person A.I.P.P Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees C- P f2c �t(Z�ol�3 (�?4 40 YOUIZA1 -0S f'oachella Valley Unified School District '$ 3-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: 7 INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: PGA West Date: January 13, 2014 Owner's Name: Mr. &: Mrs. Ed Wiener Phone No. Project Address: 81-275 Golf View, LaQuinta Project Description: Addition under existingpatio overhang APN: 762-390-029 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Total Square Feet of Building Area: 245 Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: January 13, 2014 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code 17620 65995 Number of Sq.Ft. 245 Amount per Sq.Ft. $0.00 Amount Collected $0.00 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Nsoe Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: (x �`�— ,Lia;� J NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:c/mydocs/devfces/cerinificale of compliance fbnu updated 3-2007 11/2010 <I 0 • • BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. & Mrs. Ed Weiner 81-275 Golf View Drive La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive , Palm Desert, Ca 92211 (760) 200-4780 Job Number: RECEIVED AUG 14 2013 J Cm OF LA QUINTA co MMUNM DEVELOPMENT Date: CITY OF LA QUANT 8/9/2013 BUDDING & SAFETY DEPT. APPROVED FOR CONST The EnergyPro computer program has been used to perform the calculations summarized in this co pliance report. This progra �pPr vnllnd is authorized by the California Energy Commission for use with both the Residential and Nonresiden ial 2008 B ild' g ergy Effici y Standards. J DATE This program developed by EnergySoft, LLC—www.energystoft.com. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2013-08-09709:07:58 ID: -- 0 0 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary 2 3 9 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY LEnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 • • • PERFORMANCE CERTIFICATE; Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Ed Weiner Building Type m Single Family ❑ Addition Alone 0 Multi Family m Existing+ Addition/Alteration Date 8/9/2013 Project Address 81-275 Golf View Drive La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,677 Addition 245 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity 0 Features see Part 2 of 5 Status Roof Wood Framed Attic R-11 3,432 Existing Wall Wood Framed None 2,769 Existing Door Opaque Door None 20 Existing Slab Unheated Slab -on -Grade None 3,432 Perim = 275' Existing Roof Wood Framed Attic R-30 245 New Wall Wood Framed R-13 440 New Slab Unheated Slab -on -Grade None 245 Perim = 45' New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Left (E) 41.5 1.040 0.76 none none Bug Screen Existing Rear (S) 25.0 1.040 0.76 none none Bug Screen Existing Rear (S) 207.0 1.040 0.76 none none Bug Screen Removed Rear (S) 244.0 0.790 0.59 none none Buo Screen New Right (w) 20.0 1.040 0.76 none none Bug Screer Removed Right (W) 84.0 1.040 0.76 none none Bug Screen Existing Front (N) 168.0 1.040 0.76 none none Bug Screen Existing Left (E) 24.0 0.790 0.59 none none Bug Screen New Right (tM 18.0 0.790 0.59 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 4 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location _ R -Value S_tatu_s Existing HVAC Ducted Ducted Attic, Ceiling Ins, v4;(6ffy n F14A 0 1 J IN EFA-rg Rt m nj APPREWED WATER HEATING FOR CONSTRUCTIO Ot . Type Gallons Min. Eff Distrilbution ltatu �E BY- EnergyPro 5.1 by Ener Soft User Number., 6712 RunCode: 2013-08-09T09:07:58 ID: Pa e 3 of 11 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name Mr. & Mrs. Ed Weiner Building Type ® Single Family 0 Addition Alone O Multi Family m Existing+ Addition/Alteration Date $/9/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. ITV II BUILDINGr— APPROVED FOR CONSTRUCTION DATE --__ BY— hhemvPm 5.16 EnemySoft User Number: 6712 RunCode: 2013-08-09T09:07:58 /D: Page 4 of 11 0 • 0 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type O Single Family D Addition Alone Date Mr. & Mrs. Ed Weiner 1 D Multi Family m Existing+ Addition/Alteration 8/9/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 23.94 20.56 3.39 Space Cooling 234.40 205.43 28.97 Fans 43.57 38.08 5.49 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 301.91 264.06 37.85 Percent Better Than Standard: 12.5 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 350 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 1,048 168 Fuel Available at Site: Natural Gas (E) 1,008 66 Raised Floor Area: 0 (S) 742 173 Slab on Grade Area: 3,677 (W 940 102 Average Ceiling Height: 15.1 Roof 3,677 0 Fenestration Average U -Factor: 0.95 TOTAL: 509 Average SHGC: 0.70 Fenestration/CFA Ratio: 13.8% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, /2013 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the prol lese"Olding-design-repces et of construction documents is consistent with the other compliance forms an I w6r , pi�fisf�;T ritab a pep i Qhs- d with an other calculations submitted with this permit application, and reco ides, t�ta c li n e in �letsa duct sealing, verification of refrigerant charge, insulation installation quality, 9 nEl'bUil�rr�� WAY • installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting / Address 77-622 Country Club Dr. Suite O Name Robert Pitch DATE _ By to City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Si a icense D' EnemyPro 5.1 by Enem ySoft User Number: 6712 RunCode: 2013-08-09709:07:58 ID: Page 5 of 11 0 • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Ed Weiner Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date $/9/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor I Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Roof 3,432 0.079 R-11 0 20 Existing 4.2.1-A2 Existing Residence Wall 827 0.356 None 80 90 Existing 4.3.1-A1 Existing Residence Wall 395 0.356 None 170 90 Existing 4.3.1-A1 Existing Residence Wall 444 0.356 None 170 90 Remove 4.3.1-A1 Existing Residence Wall 688 0.356 None 260 90 Existing 4.3.1-A1 Existing Residence Wall 127 0.356 None 260 90 Removec 4.3.1-A1 Existing Residence Wall 860 0.356 None 350 90 Existing 4.3.1-.41 Existing Residence Door 20 0.500 None 350 90 Existing 4.5.1-.A4 Existin Residence Slab 3,432 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 245 0.031 R-30 0 0 New 4.2.1-A20 Addition Wall 116 0.102 R-13 80 90 New 4.3.1-A3 Addition Wall 174 0.102 R-13 170 90 New 4.3.1-A3 Addition Wall 150 0.102 R-13 260 90 New 4.3.1-A3 Addition Slab 245 0.730 None 0 180 New 4.4.7-A1 Addition FENESTRATION SURFACE DETAILS T e Area U -Factor SHGC Azm Status Glazin T e Location/Comments1 Window 30.0 1.040 Default 0.76 Default 80 Existing single Non Metal Clear Existing Residence 2 ID Window 2.3 1.040 Default 0.76 Default 80 Existing single Non Metal Clear Existing Residence 3 Window 2.3 1.040 Default 0.76 Default 80 Existin sin le Non Metal Clear Existin Residence 4 Window 2.3 1.040 Default 0.76 Default 80 Existing single Non Metal Clear Existing Residence Window 2.3 1.040 Default 0.76 Default 80 Existing single Non Metal Clear Existing Residence 6 Window 2.3 1.040 Default 0.76 Default 80 Existing single Non Metal Clear Existing Residence 7 Window 25.0 1.040 Default 0.76 Default 170 Existing single Non Metal Clear Existing Residence 8 Window 64.0 1.040 Default 0.76 Default 170 Removed single Non Metal Clear Existing Residence 9 Window 15.0 1.040 Default 0.76 Default 170 Removed single Non Metal Clear Existing Residence 10 Window 64.0 1.040 Default 0.76 Default 170 Removed single Non Metal Clear Existing Residence 11 Window 64.0 1.040 Default 0.76 Default 170 Removed single Non Metal Clear Existing Residence 12 Window 96.0 0.790 Default 0.59 Default 170 New Dual Metal Tint Existing Residence 13 Window 20.0 1.040 Default 0.76 Default 260 Removed single Non Metal Clear Existing Residence 14 Window 20.0 1.040 Default 0.76 Default 260 Existing single Non Metal Clear Existing Residence 15 Window 64.0 1.040 Default 0.76 Default 260 Existing single Non Metal Clear Existing Residence 16 Window 64.0 1.040 Default 0.76 Default 350 Existing single Non Metal Clear Existing Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot FWd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len Hot 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 10 Buo Screen Bug Screen 0.76 0.76 . , bt `-L-, NO E 11 Bug Screen 0.76 A D / 12 Bug Screen 0.76 -rqCE! 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16T Bug Screen 0.76 M IF Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-09709:07:58 ID: Page 6 of 11 • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Mr. & Mrs. Ed Weiner Building Type m Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration Date 8/9/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area 1 -11 -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 64.0 1.040 Default 0.76 Default 350 Existing single Non Metal Clear Existing Residence 18 Window 28.0 1.040 Default 0.76 Default 350 Existing single Non Metal Clear Existing Residence 19 Window 12.0 1.040 Default 0.76 Default 350 Existing single Non Metal Clear Existing Residence 20 Window 24.0 0.790 Default 0.59 Default 80 New Dual Metal Tint Addition 21 Window 148.0 0.790 Default 0.59 Default 170 New Dual Metal Tint Addition 22 Window 9.0 0.790 Default 0.59 Default 260 New Dual Metal Tint Addition 23 Window 9.0 0.790 Default 0.59 Default 260 New Dual Metal Tint Addition (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hat I Wd Ove hanq Left Fin Ri ht in Len Hat LExt RExt Dist Len Hat Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Buq Screen 0.76 23 Bug Screen 0.76 Ir JTrys CONS RUC: DATE _ BY Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2013-08-09T09:07: 'age 7 of 11 • 0 0 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Mr. & Mrs. Ed Weiner Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 8/9/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Existing HVAC Existing Residence 3,432 52,166 1960 Addition 245 3,430 Totals 1 2451 3,4321 0 01 1 HVAC SYSTEMS System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing HVAC 4 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Q Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Ext. Standby Tank Loss or Insul. R- Pilot Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft) -075 a — CITY C BUiLUirJ S stem Name, E--) E !F LA CSU f nl A 8pi�eAF Ep6)E Tnsu. )f'l'ap h j_amet r Thic . Qty. HP Plenum Outside Buried ❑ rM V ee'1� ❑ , VJIM't ❑ DAT EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-09709:07:58 ID: Page 8 of 11 4 • MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Mr. & Mrs. Ed Weiner Date 8/9/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. ,-*§l 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the -outside of the building, are prohibited. :.Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water 'tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. '§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insul ed between heating source and indirect hot -water tank shall be insulated to Table 150-B and E nation 150-A. T §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems A ps , th ui a s�o Ta 123-A. I le §150(j)3A: Insulation is protected from damage, including that due to sunlight, moist u , e u' e"_I ai teri e - §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a v por ret t o is _n d1Uk n conditioned space. FOR CONSTRUCTinm 150(j)4: Solar water-heatingsystems and/or collectors are certified b the Solar Rati and Certification Corporation. L!n BY EnergyPro 5.1 by EnergySoft User Number 6712 RunCode: 2013-08-09709:07:58 ID: Page 9 of 11 C� L_� • MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. & Mrs. Ed Weiner 8/9/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes .unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(0): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat um or as heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall m tT trrequiremerrits of §150(k). 4150(k)7: All switching devices and controls shall meet the requirements of §150 k /q §150(k)8: A minimum of 50 percent of the total rated wattage of permanently inst Ile i ( �rS a�4i le cy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 1 + 0 watts r wAPurn pr$er than''22 5 O f maybe from high low luminaires the kit ISI d�Sjr�ual exempt the 50% efficacy requirement when: all efficacy n gn on o cupant sensor, dimmer, energy management system (EMCS), or a multi -scene program able cp. �$y§t� n� af.9& tly ins Iled luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms ar i e c y led by manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no moieAW 20 watts of pow per linear foot of illuminated cabinet. N EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-09709:07:58 /D: Page 10 of 11 • • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr. & Mrs. Ed Weiner 8/9/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less .than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between ;,the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more f dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-08-09709:07:58 0: Page 11 of 11