Loading...
05-0854 (RPL)O.' Box 1504 3495 CALLE TAMPICO 4 QUINTA, CALIFORNIA 92253 Application NiTmber Property Address . . . APN: Application description Property Zoning . . . . Application valuation . BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760),777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 05-00000854 Date 3/15/05 . . . 81305 GOLF VIEW DR 762-410-030- . . . POOL - RESIDENTIAL . . . LOW DENSITY RESIDENTIAL . . . 11000 Owner Contractor ------------------------ ------------------------ SPENCER TURNER CAL WEST POOLS AND SPAS INC 81-305 GOLF VIEW DRIVE •P 0 BOX 890898 LA QUINTA CA 92253 TEMECULA CA 92589 (951) 453-2924 WCC: STATE.FUND WC: 000618158 07/01/05 CSLB: 688893 05/31/06 CCC: C53 C61 D35 --------------------------7------------------------------------------------- Permit BLDG'POOL PERMIT Additional desc . . Permit Fee . . . . 126.00 Plan Check Fee 81.90 Issue Date . . . . Valuation . . . . 11000 Qty Unit Charge Per Extension BASE .FEE 45.00 9.00 9.0000 THOU BLDG 2,001-25,000 81.00 ---------------------------------------------------------------------------- Permit . . . . . . MECH POOL Additional desc Permit Fee 24.00 Plan Check Fee 6.00 Issue Date . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 ---------------------------------------------------------------------------- Permit . . . . . . ELEC POOL PERMIT -RES Additional desc Permit Fee . . . . 45.00 Plan Check Fee 11.25 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 30.0000 EA ELEC PRIVATE SWIMMING POOL 30.00 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 27.00 Plan Check Fee 6.75 P.O. Box 1504• �� VOICE (760) 777-7014 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: rho �� Date: Applicant: Applicant's Mailing Address: C To Architect or Engineer: Architect or Engineer's Address: ;AIA- Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals rde, and my License is in full force and effect. "License Class ,rMense ate — �� Contractor QUOWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am xer♦rp from t e Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U 1 am exempt under Sec. , BA P.C. for this reason Date Owner. WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 f the Labor Code, for the performance of the work for which this permit is i ed. I have and will maintain workers' co nsurance, as , i by S�77 of the L�A� ance of the work for which this permit is i s d. i e ca an cy mbar arner Policy Numb I e 'fy that, i th erfance of the work for which this pe i u d, mplo any person in any manner so as to become subject to the workers' compensation laws of California, and agree th should e workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. DtDa e —L 0 - �AppIican WARNING: FAILURE TO SECURE WORKERS' COMPE ATIO COVERAG IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name 444 Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I a e t com ly with all city and county ordinances and state laws relating to building construction, andherebyauthorize representatives of this county to enter n abo -menti, n roperty for inspection purposes. Dated `�� Signature (Applicant or Agent)i./ T4hf 4 4 a" P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA; CALIFORNIA 92253 BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760),777-7012 FAX (760) 777-7011. INSPECTION REQUESTS (760) 777-7153 Page . 2 Application Number . . . . . 05-00000854 Date 3/15/05 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA PLB FIXTURE 6.00 1.00 3.0000 EA PLB.WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments FIBERGLASS SPA ONLY. ICBO REPORT ER 2417. GAS LINE FOR BBQ. ALARMS/BARRIERS SHALL BE IN PLACE PRIOR TO PRE -PLASTER INSPECTION. EQUIPMENT ENCLOSURE NOT INCLUDED IN PERMIT. Fee summary. ----------------- Charged Paid Credited ------------------------------ Due ---------- Permit Fee Total 222.00 .00 .00 222.00 Plan Check Total 105.90 .00 .00 105.90 Grand Total 327.90 .00 .00 327.90 P.O. Box 1504ICE VOICE (760) 777-7012 78-495 CALLS TAMPICo FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in.full force and effect. License Class License No. Date Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. . BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lenders Name Lenders Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to complywith all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date Signature (Applicant or Agent): IE TM E R-2417 �SREPORT Reissued January 1, 2002 ICBO Evaluation Service, Inc. - 5360 Workman Mill Road, Whittier, California 90601 - www.icboes.org Filing Category: SWIMMING POOLS AND SPAS FIBERGLASS ONE-PIECE SWIMMING POOLS AND SPAS SAN JUAN PRODUCTS 2302 LASSO LANE LAKELAND, FLORIDA 33801 A.E.C.CJSAN JUAN POOLS 850 NORTH DAVIDSON BOULEVARD ELOY, ARIZONA 85231 1.0 SUBJECT Fiberglass One-piece Swimming Pools and Spas. 2.0 DESCRIPTION 2.1 General: The San Juan Products swimming pools and spas consist of one-piece fiberglass construction, shop -formed over a mold. The model numbers and sizes are shown on Table 1. All references to pools in this report apply also to spas. The fiberglass pool is formed against a one-piece interior form or mold in the following manner. The form is treated with a parting agent to ensure separation of the liner from the mold after fabrication. An isophthalic/neopentyl-glycol gel coating 30 mils (0.8 mm) thick is spray -applied to the surface of the form. A fiberglass hand layup consisting of a 11/2 -ounce (40 g) reinforcing mat of random chopped strands of fiberglass is applied to the cured gel coating, which is then treated with a 100% pure vinylester polyester resin applied with a 35 percent minimum saturation factor. A second layer consisting of "/2 -ounce (40 g) reinforcing mat is laid over the previous layer and saturated with a 1 QO% pure vinylester resin. The third layer consisting of a 24 -ounce (700 g) woven roving is applied over the previous construction and saturated with another coating of a 100% pure vinylester resin. The process of alternating layers of fiberglass mat and woven roving saturated with resin is continued until a total of five layers has been built up. The completed pool has a minimum cured thickness of/1e inch (4.8 mm). The woven roving and reinforcing mats are applied so that the lapped splices between the individual rolls of the material occur at the same locations and are 6 to 8 inches (152 to 203 mm) wide. This provides an additional thickness (a total of 10 plies) to the liner in the form of periodic stiffening elements. The fiberglass has an average tensile strength of 25,452 pounds per square inch (175.47 MPa) and a modulus of rupture of 40,005 pounds per square inch (275.8 MPa). The pools have a fiberglass coping approximately 6 inches (152 mm) wide around all sides, the exterior edge of which is bent down or depressed to engage the poured -in- place concrete coping during field installation. One comer of the pool end is provided with curved steps for access. A main drain is built into the fiberglass pool at the deep end. Extending from the main drain box are the necessary service lines to the filter equipment. A gravel sump is provided beneath the main drain base to collect any ground water or drainage from the sand bed on which the pool is installed. Leading from this gravel sump is a 11/2 -inch (38.1 mm) plastic pipe extending to ground level which is utilized to relieve hydrostatic pressure by collecting and disposing of ground or seepage water when it becomes necessary to empty the pool. The pool is provided at the deep end with an underwater recessed light pocket and floodlight. The floodlight and all electrical apparatus in connection with the pool are required to be adequately grounded. All plumbing and electrical work is required to comply with the codes in effect at the construction site. The pool design requires it to remain full of water at all times. A permanent sign is to be attached to the plumbing equipment and is to read as follows: "Notice—Pool is designed to remain full of water at all times. Pool shell may be damaged if water level is allowed to drop below the pool skimmer. When appreciable drawdown is noticed or if it becomes necessary to drain the pool, contact San Juan Pools, Inc., or its agents for instructions." A pressure - sensitive plastic sticker will be installed adjacent to the above sign by the manufacturing licensee, giving his name, address and telephone number. 2.2 Installation: The pool may be installed without a soil investigation by a qualified engineer, providing none of the following conditions are encountered and the site is approved by the building official: 1. The existence of ground water within the depth of the pool excavation. 2. The existence of an uncompacted fill in contact with any portion of the pool. 3. The existence of any expansive or adobe -type soils, at or within the confines of the pool area. 4. The existence of any soil types whose angle of repose will not support the walls of the excavation at the desired slopes. 5. The location of the proposed pool excavation so that it would have a tendency to endanger adjacent structures. If one or more of the above conditions are encountered, the excavation for the pool shall immediately cease until the specific conditions at the site have been reviewed and recommendations made by a qualified engineer. The engineer's report of this review and recommendation is to be submitted to the building official having jurisdiction over the construction site, and his approval obtained prior to continuance of the work. REPORTS'" are nut to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to he construed as an endorsement of the subject of the rcporr or a recommendation for iRs use. There is no warranty by ICBG Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2002 Page 1 of 3 Page 2 of 3 The excavation for the pool consists of removing the existing soil from the proposed area, utilizing chain -type screeds to ensure a 6 -inch (152 mm) minimum over - excavation at the pool bottom and all sides. The required drains and plumbing work are installed and a contoured layer of clean sand is placed in the lower areas of the pool up to a point at which sloughing would occur. The pool is then placed on this sand bed and carefully aligned and leveled to preclude any buckling or irregularities in the fiberglass. Water is introduced into the pool proper and up to a level approximately equal with the sand layer. The backfilling with sand is carefully continued upward, maintaining approximately a uniform height around the four sides of the pool at all times. The sand is consolidated by flooding with water as the work progresses. The pool is simultaneously filled with water as the backfilling progresses, maintaining approximately equal levels. The sand backfill is stopped at the level of the bottom of the concrete coping on all sides of the pool. .The outside lip of the fiberglass pool coping detail is embedded in a concrete walkway installed around the entire pool. See Figure 1 for complete details. The walkway is reinforced with 6 -inch -by -6 -inch (152 mm by 152 mm) No. 10-0 wire mesh. 2.3 Identification: Each pool or spa is identified by a coded imprint above or below the skimmer signifying model and date of manufacturing. The company name and factory letter are also noted. TABLE 1 ER -2417 3.0 EVIDENCE SUBMITTED An engineering report, detailed plans specifications and internal quality control manual. 4.0 FINDINGS That the Fiberglass One-piece Swimming Pools and Spas described in this report comply with the 1997 Uniform Building Code7kl, subject to the following conditions: 4.1 Construction and pool installation comply with this report and the manufacturer's installation Instructions. 4.2 Electrical and plumbing installations comply with the respective codes in effect at the construction site. 4.3 Pools are installed by a factory -trained and licensed installer or agent approved by San Juan Products. 4.4 Clearances from slopes must be as set forth in Section 1806.5.4 of the code. 4.5 Barriers in accordance with Appendix Chapter 4, Division 1 of the code are provided where pools are located on premises of Group R, Division 3, occupancies." This report is subject to re-examination in two years. MODEL NO. WIDTH (111.4n.) LENGTH .in. DEPTH arh.J CAPACITY (90 1,2,3 Shall End Dee End 025 8-0 16.0 2-0 uniform depth 1,800 0761, 8-0 16-0 4-0 uniform depth 2,860 Blob 8-0 17-0 4.0 undorn depth 3.600 025 &a 19-0 4-0 unitonm depth 3.600 050 84 38-0 4-0 We- depth 6.500 750be 88 23-0 48 uniform depth 5.800 775b8 86 40-0 48 uniform depth 10,000 0851, 9.8 176 48 uniform depth 3200 060b 100 22-0 4.800 930b 11-0 18-0 4-0 uniform depth 4.400 650b 12-0 16-0 5-0 uniform depth 5200 .6 12-0 16.0 4-0 uniform depth 4,900 7006 12-0 20-0 4-0 uniform depth 5.800 920b 12-0 20-0 4-0 uniform depth 6,000 300b 12-0 22-0 3-8 urlform depth1 6.028 1 75b 12-0 24-0 6,600 f 75 12-0 26-0 5-0 7,500 100 12-0 27-0 36 58 8,000 8006 12-0 27.7 96 5-0 7,000 125b 1210 28-0 36 56 81600 135b 12-0 28-0 96 66 8,400 210bk 12-0 28-0 36 6-0 8,000 150 12-0 28-0 4-0 4-10 81900 300b 12-0 30-0 3-5 B-0 13,000 2001, 12-0 31-0 3-6 56 9,000 145be 12-0 34-0 3-6 SE 6,600 150bk 13-0 20-0 36 56 6,800 870b 13-0 29.0 36 6-0 10,000 350 130 34-0 96 5-0 10,000 400b 14-0 324 36 56 11,600 450b 14-0 32-0 3.8 8-0 14,000 470b 14-0 324 36 8-0 13,500 225bk 14-0 334 3.8 5-10 12,000 480bk 14-0 334 36 , 6-0 13.500 490 14-0 33.0 36 6-0 15,500 375b 14.3 30-0 36. 56 9,600 9601, 16-0 32-0 3-6 6-0 13,500 850bk 18-0 33-0 S-8 6.10 13,000 8406 18-0 34-0 3-6 56 13.500 S50bk 16.0 40-0 88 84 18.000 675b 16-0 40.0 3_6 8-0 20,500 875bs 18-0 40-0 36 56 14,000 590 16-6 406 _ 36 4 0 22,0e0 5000 17-0 35-0 3.5 9-1 16,000 537.0 37.0 36 9-0 17,500 6501,4 17-0 42-0 2.10 8-1 17,000 , b denotes pool with bench It denotes pool Iddney tlhepa s denotes pool with attached spa For SI: 11 inch - 25.4 mm, 1 foot m 304.8 mm, 1 gallon - 3.79 L Page 3 of 3 ER -2417 6W BEAM AND WALKWAY 4�/� ����� � l• rOr«lswc�r Gs�]C.Ll3[LL''��.'.�rt Cb�uMcrvG��irc /Q'NCi�rN KOTlJr '�: hit LYAr(A sat mix �s 0014 ArG: J• L TM/i GfAwING iYALI 4W LaSto /N COVU CTJAV jeoWo9 c �b ,Y LONAWreo J—P (MV 1I/AY L16YSlAtf/CTIOY "Cv,--ZC4r1ONJ, A rI t G a *f4-:TwAr 46fLL of QGVILMVWJ AOFOVAV PO&. a Truer ca w%wrro SSW Am FIGURE 1 J j:QCo, f, 51 spi n- riC9urm. 5' 4 56' Co- Pis I �LL.V:Z- C -C a -t O -A c, H 0v Sv. CAS W (-eu -T \ 5�w% vfin;;z.'Cr� ` CIS+ 9z:5(oZ CA- �S 1- (cn 1 SPA Io` 4. Z' CA 18' 18' �.QuiP 5' CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE�� 8' ,e)k3as DoT \116 �. l� Q (�j ► rn Cly Ci2ZS1 Scale: 0.09 in. per ft.