Loading...
05-0375 (AR)AW to ljl Q• BUILDING & SAFETY DEPARTMENT A .-v.Y. �• 11„ _ - �1r O. Bio 1504 (760),777-7012 Fit pF � -495 C�LLE TAMPICO FAX (760) 777-7011 Q IN TA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 C1 FIPICE �Ep1. BUILDING PERMIT Application Number . . . . 0'5=000_0.0-3_7.5 Date 2/10/05 Property Address . . . . . . 81390 GOLF VIEW DR APN: 762-410-022- - - Application description . . . ADDITION.- RESIDENTIAL Property Zoning . . . LOW DENSITY RESIDENTIAL Application valuation 15660 Owner Contractor MAGANA PARKER CONSTR COMPANY, DENNIS .81-390 GOLF VIEW DR. 72870 TAMARISK STREET LA QUINTA CA 92253 PALM DESERT CA 92260 (760)'340-2482 WCC: EXEMPT WC: EXEMPT 07/31/05 CSLB: 828575 12/31/05 CCC: B --- -- Structure Information- CONVERT GARAGE TO OFFICE AREA. ----- Construction Type TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION .2001 CBC FLOOD ZONE NO 1ST FLOOR SQUARE .FOOTAGE 232.00 ------------------------------------------------------------- ---------------- Permit . . . BUILDING PERMIT Additional desc Permit Fee 171.00 Plan Check Fee 111.15 Issue Date Valuation . . . . 15660 Qty Unit Charge Per Extension BASE FEE 45.00 14.00. 9.0000 THOU BLDG 2,001-25,000 126.00 ------------------------------------------------ : . . . . ELECT - ADD/ALT/REM Additional desc Permit Fee . . . . 23.12 Plan Check Fee 5.78 Issue Date Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 232.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 8.12 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 33.00 Plan Check Fee 80.25 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension V .W P.O. Box 1504 • VOICE (760) 777-7012 7$-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: O J - 6>,77 Date: Applicant: Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and2y Licen�is in full force and effect. �T� �� c'S �5 `icense'Class) /� L Eens-__�e No. a C S OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Cartier Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. rDate US Applicant ----).rA; WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I 5Qree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to er—ru., �he nt' ed property for inspection purposes. Signature (Applicant or Agent):- Page 2 Application Number •05-00000375 Date 2/10/05 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=LOOK 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 ---------------------------------------------------------------------------- Special Notes and Comments CONVERT GARAGE TO OFFICE AREA 232 SQ. FT. 2/3/05 1:13:51 PM JJOHNSON ----------------------------------------7----------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 11.12 STRONG MOTION (SMI) - RES 1.56 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 227.12 .00 .00 227.12 Plan Check Total 125.18 .00 .00 125.18 Other Fee Total 12.68 .00 .00 12.68 Grand Total 364.98 ..00 .00 364.98 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATF., RFr.F.TPT- CHF.C.K B. rNITIAIS- CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence i§ at The Legends at' -PGA West Date: February 10, 2005 Owner's Name: M/M Magana Phone No. Project Address: 81390 Golf View Drive La Quinta, CA Project Description: Conversion from garage to living space APN: 762-410-022 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 232 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: February 10, 2005 Signature: **********************************A************************************ SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 232 $ 0.00 $ 0.00 Building Permit Application Completed: Yes/No Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement By: Carey M. Carlson, Asst. Supt., Business Services Note: Any addition to a home that is 500 sq. ft. or less is exempt from Developer Fees.. Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. hicOrtilicalQc;fcompliance i?rm 41hie TO CLSii.dcc 1/16/03 T Y; TITLE 24 REPORT Gni Title 24 Report for: GUSTAVO MAGANA PGA WEST LA QUINTA, CA'.` ' Project Designer: t CITY OF OWNER BUILDING LA QUINTA SAFETY DEPT. . GUSTAVO MAGANA APPROVED."- LA QUINTA, CA FOR CONST UCTIO DAT O.S #0!1.375 BY Report Prepared By: ADRIANA GIL GCS Group y . 74-854 Velie`Way, Suite 5 i Palm Desert, CA 92260 ' i (760) 340-3528 M3NMO 3H130 3SN3cM 3H11V 03dwna 83NIVINOD 3H13AVH Ol All3 3H1303 AVW ' OS 00 013a(111d3 'AHVSS303N SV MLLdW3 ISPIN M N01 nHISN00 30 S3SVHd ' il'!. 5, idea 311S 80f 3Hl NO 030038 SI. ` Job Number: __j1',;1ViN00 S18930 03ZIS A131VRD30V NVp ADY1'32=1104 Date:1.. 1 /12/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is -authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. ' This program developed by EnergySoft, LLC (415) 883-5900. i EnergyPro 3`1 By EnergySoft -Job Number: ADY132-1104 User Number: 5553 A TABLE OF CONTENTS i. Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 5 Form C -2R Computer Method Summary 7 HVAC System Heating and Cooling Loads Summary 10 EnergyPro 3.1 By EnergySoft Job Number: ADY132-1104 User Number: 5553 Certificate of rke r„�Name:_ Residential (Part 1 of 2) CF -1 R GUSTAVO MAGANA 1/12/2005 Profec Title , Date PGA WEST LA QUINTA Project Address Building Permit # GLS Group (760) 340-3528 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 232 ft2 Average Ceiling Height: 8.0 ft Total Conditioned Slab Area: 232 ft2 Building Type: (check one or more) ❑ Single Family Detached ❑ Addition X] Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deq Floor Construction Type: FX] Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall A(( t,, 12Y S Solid Wood Door None 0.387 Exterior Door FENESTRATION Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (South) 64.0 0.65 0.40 Bug Screen ❑ X❑ ❑ X❑ Left (West) 8.0 0.65 0.40 Bug Screen ❑ x❑ ❑ x❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 01/1210507:18:58 Run Code: 1105543138 Ener Pro 3.1 By Ener Soft User Number: 5553 Job Number: ADY132-1104 Page: 3 of 10 Certificate-oforx/l)liance: Residential (Part2 oft) CF -1R GUSTAVO MAGANA Project Title Date 1/12/2005 HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Gas Fireri Heat Pump 7.20 COP Ductless / with Fan n/a Setback 0.0 kW Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Gas Heat Pump 11.00 COP Ductless n/a Setback HVAC Minis lit . ystpm WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS GUMPLIANGE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name Title/Firm: OWNER Address: GUSTAVO MAGANA LA QUINTA, CA Telephone Lic. #: (sign ure) Iq (date) Enforcemen gency Name: Title/Firm: Address: Telephone: Name: ADRIANA GIL Title/Firm: GLS Group Address: 74-854 Velie Way, Suite 5 Palm Desert, CA 92260 Telephone: (760) 340-3528 (signature) (date) natu IEnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY132-1104 Page:4 of 10 1 Mandatory Measu NOTE: Lowrise residential buildings subie ?s Checklist: Residential (Page 1 of 2) MF -1 R the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures FV 1JAI '§ 150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. ❑§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does i( not apply to exterior mass walls). E"§ 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent. §150(l): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§ 150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. a§ 150(i): Setback thermostat on all applicable heating and/or cooling systems. FXJ § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY132-1104 Page:5 of 10 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential building subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back -rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. X] § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) . ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)'I: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. X1 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number: 5553 Job Number: ADY132-1104 Page:6 of 10 Computer Method. SaAnmary (Part 1 of 3) C -2R GUSTAVO- MA-GANA 232. 0.02.4_ 1/_1.2/_2QQ5 Project Title Wall— -42. Date RGA__WEST l A_Q_UI.NTA 9.0_ Wall_ 81 Project Address _27-0- 9.0_ Building Permit # GLS Group(760) 0,088 340-3528 90 Documentation Author J. Telephone Plan Check/Date Compute_r_P_e.rf-or_m.an.ce Wall_ 15 _0.08.8- Field Check/Date Compliance Method (Package or Computer) F-1 Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin F-1 Space Heating 5.03 0.43 4.60 Space Cooling 61:59 6.57 55.02 ❑❑ Domestic Hot Water 0.00 0.00 0.00 Totals 66.62 7.00 59.62 Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units; Number of Stories: BUILDING ZONE INFORMATION Zone Name 232 ft2 Single Fam Attached (South) 180 deg 1.00 1 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Total Fenestration Area: 31.1 % Total Conditioned Volume: 1,853 ft 3 Total Conditioned Slab Area: 232 ft 2 # of Floor Area Volume Units Zone Type _HVA_ C_Mini_Split_S.ystem 232 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt _Roof 232. 0.02.4_ 0 1.8_ Wall— -42. _0..0.8.8_ 1.8.0_ 9.0_ Wall_ 81 _0.0.8.8_ _27-0- 9.0_ Wall_ 11.5 0,088 1.8.0 90 _Door J. 0.387_ 1.80 90_ Wall_ 8.9_ _0.08.8- —90--90- Solar Gains 1.,853 1..0.0_ Conditioned_ Y / N Form 3 Reference IX DK [X IX [XI ❑ ❑ ❑ ❑.R_1.3_W.all_(W.1.3.2x4..J-6.) ❑ ❑ F-1_R_1.3_Wall_(.W.1.3..2x4..1.6.) R_38_RooQR_ 38..2x4..24) _R_1.3_Wall_(W.1.3..2x4..16.) .R_1.3_W-aI1—(_W.1.3.2x4..16) _Soli.d_W_ood_Door ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ F-1 F-1 ❑❑ F-1 F-1 n n 1-1 F-1 ❑❑ ❑❑ ❑❑ ❑❑ Q ❑❑ ❑❑ F-1 r-1 F-1 F-1 WHOLE WHOLE WHOLE -WHOLE WHOLE -WHOLE Thermostat Vent Type Hgt. Area _Setback— 2 _n/a Location / Comments EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY132-1104 Paw:7 of 10 1 Computer Methad,Sdfmmary (Part 2 of 3) C -2R GUSTAYO rylAGANA 1/12/2005 Project TiVe Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _L Window F_cont_(.S.outh) _8..0- _0..6.5.0_ 0._4.0 1.8.0_ _9.0. DEEAULT DB.LP_ANE WHOLE 2 Window Front (South 8.0 0.650 0.40 180 90 DEFAULT DBL PANE WHOLE 3 Window Front South) 8.0 0.650 0.40 180 90 DEFAULT DBL PANE WHOLE 4 Window Left _(West)_ 8.0 0.650 0.40 270 90 DEFAULT DBL PANE WHOLE 5 Window Front (South) 40.0 0.650 0.40 180 90 DEFAULT DBL PANE WHOLE INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 _ 4 Bug Screen 0.76 5 Bug Screen 0.76 Run Initiation Time_01N2I05 07-l8_58 Run Code: 1105543138 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY132-1104 Page:8 of 10 Computer Method, Sconmary (Part 3 of 3) C -2R GUSTAVO MAGANA 1/12/2005 Project Titia Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 64 0.76 0.0 0 WHOLE Heating Equipment Minimum Type (furnace, heat Efficiency pump, etc.) (AFUE/HSPF)(ducts/attic, Distribution Type and Location etc.) Duct R -Value Thermostat Type Location / Comments Gas Fired Heat Pump 7.20 COP Ductless / with Fan n/a Setback 0_0 kW Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, . Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Gas Heat Pump 11_00 COP Ductless n/a Setback HVAC Mini Split ay_stem WATER HEATING SYSTEMS Ratedl Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) l) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas.water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 01/12/0507:18:58 Run Code: 1105543138 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY132-1104 Page:9 of 10 _ HVAC SYSTEM HE,Ao- NG AND COOLING LOADS SUMMARY PROJECT NAME DATE ,1 GUSTAVO MAGANA 1/12/2005 SYSTEM NAME FLOOR AREA HVAC Mini Split System 232 (STEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 177 4,711 108 158 6,902 0 236 345 0 0 0 0 0 0 0 0 0 236 345 5,182 108 7,592 FUJITSU AOU12C1 9,862 654 10,500 Total Adjusted System Output g g62 65a 10,500 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) � 26.0 of 69.0 of 110.0 of Supply Air Ducts Outside Air 0 cfm Heating Coil 110.0 of ROOMS 69.0 of 69.0 of 111.0 / 77.6 of >---;I Outside Air 0 cfm 80.0/62.8 of �% Return Air Ducts 4 ETRICS (Airstream Temperatures at 80.0 / 62.8 of . 55.0 / 53.6 of Cooling Coil h Return Air Ducts `i Supply Air Ducts 55.0/53 . 6 of 38.2% R.H. ROOMS 80.0 / 62.8 of EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY132-1104 Page:10 of 10 I � CERTIFICATE. OF COMPLIANCE: RESIDENTIAL, Pae 1 of 3 CF -1R I i•��. ��D(TZoC b-tt - 1?ro t itl Date PfOdSS�� � 7 cn �� [� �j Building permit s Doc�tat o�TelMono one Plan Check / Date �—1 Field Check / Date Compliance Method (Package;or Computer) Climate Zone Morcenieni Agency use y O Ilk _ Left 9-KNERAL INEO AVON _ Total Conditioned Floor Area (! ft2 Avenge Ceili - _ Conditioned Slab Floor Area ft2 CITY OF LA QUINTA Building Type: Single Family Addition (check one or more) Multi -Family Existing -Plus -addition BUILDING & SAFETY DEPT. APPROVED P P R O V ED Front Orientation: 4 SNott South / East / West/ All Orientations FOR CONSTRUCTION put rront orientation in degrees rTom'. rue North and circone) Number of Stories I Number l C DAT'– / 0.06 BVS - j-' of Dwelling Units: Floor Construction Type: S! aised Floor (circle one or both; fir^ RADIANT BARRIER (MgUired in climate tongs 2.4, . Required for this submittal._._ yes —no BUILDING ENVELOPE INSULATIQN 1 Skylight Component Frame p Type Cavity Type wd = wood Insulation stl = steel R -Value Sheathing Total R- Insulation Value` R -Value ,— �ssen:bl� Location/Comments U -Factor' . (attic, garage, typical, etc.) Wall LIQ -Z ZT 14 73, Z12 JP5_ 11 Wall w -p . –2 2 P_Z . Roof W r Z Roof Left O Floor _ Left Floor 1 Slab Ede ; O 'For R er scti 've gmplio- c_e. ,IaWMalme'and Assembly.U-Factor , amo required for a wwd-framed Lyall that mee:R.cavity R=� insulation mgWre_ments for. the Prescriptive Package. t FENESTRATION Shading Devices Fenestration Orien- #/T os. talion(ft) Area Fenestration U -Factor Fene,,Cmtion Exterior Overhan&sl SHOC Shadin Att. Fins Front Front Left O r _ Left 1 Rear O Rear Ri ht Right Skylight Skylight _ Compliance Forms August 2001 A-2 CER'T'IFICA'T'E OF COMPLIANCE: RESIDENT.IA-E t W.&. 4ZjD«1 o Q Project Date 2 of 3) HVAC SYSTE_M.s Note: Input hydronic or combined hydronic data under Water Heating S��tems, except Desip. Heating Load. Distribution Heating Equipment Minirrum Type and Duct or 'Piping Thermostat Heat Pump Configuration Type (furnace, hent Efficiency Location pump, etp.) (AFUE or HSTF) (ducts attic etc.) -Value Type (split or.vaeka a) Cooling Equipment Minimum Duct heat Puinp Type (air conditioner, Efficiency Location Duct Thermostat Configuration heat pimp evap. cooling) (SG] Its - (attic, etc.) R -Value Type (split or. package) SEALED DUCTS and TXVs (or .Alterusa�tivg Measure�� Sealed Ducts (all olimate zones) (Installer testing and certification and HERS rater field verification required) ❑ TXVs, readily accessible (climate tones 2 and 5-15 only) (Installer testing and certification and 11L',RS !torr, or field verification squired) i] Refrigerant Charge/Air Flow (climate zonos 2 and 8-15 only) (Installer testing and certification and HERS Rater or field verification_ required) OR Alternative to Sealed Ducts and TXVs (see Package C or D Alternative Package Features for Project Climate Zone) Climate Zone Window SHGC Window U -.Factor. SEEM Heating WATER HEATING SYSTEMS Energy' External Rated' Tank Factor or Tank Water Heater Distribution Number Input (kW Capacity Recovery Standby' Insulation Type Type in System orBmu/ltr) (gallons) Efficiency Loss (%) R -Value 1. For small gas storage- water heaters (rated inputs of loss titan or equal t.o '15,000 Blu tu), electric resistance, and heat pump water heaters, list Energy Factor. For large gas storage water heateri (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery F.fftciency and Standby Loss. For instantaneous gas water heaters, list rated input and recovery efficiencies, S ECUL FEATURES (add extra sheets if necessary). Package C andD: TXVs, Sealed Ducts, Radiant Farriers (see installation requirements for radiant barriers in Section 8.13 of the 200 1, Residential Manual). Package C: thermal Mass (thennal mass type, covering, thickness, and description). � V W tktt���GS 01 F;--:! pliance Forms w o August 2001 A -:i CERTIFICA'T'E OF COMPLIANCE: RESIDENTIAL, (Page 3 of 3) CF -IR Project ritle Date CQMPLIANCE STAT ENT This certificate of compliance lists the buil(,;-ng features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, aul the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted fora single building plan to txbuilt in rttultiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks sec` ion. The un'ersigned recognize that compliance using duct sealing and TXVs iequires installer testi.ig and certification and field verification by an approved HERS rater. Designer or Owner (per Business and Professions Code) Tide/Fimt:L'tit..�'%1 Address: Telephone: Lic. 4: ' �6t') (date Enforcement Agency Documentation Author Name: Title✓1`itm �•� 1�"a�'o Address:{ Tddl.• . Agency: _� Telephone: (sigaature / stamp) (date) Compliance Forms August 20U1 A4 FENESTRATION - MAXIMUM ALLOWED AREA WORKSHEET WS4R Date FENESTRATION PRODUCTS -NEW CONSTRUCTION- NEW BUILDINGS Use this table for new buildine construction to account for total buildino 0/, of fenestratinn A B _ C _ D E F G 4/Type/Pos. (Front, Leff, Rear, Right, S li ht) Orientation Tot,4 Fenestration, West. Facing I At ea W Total Fenestration for N, S, E Orientation:, Area flZ CFA (ft) Total Percent of West Facing Fenestrations C/E x 100% Total %of Fenestration' Including West (D%E x 100%+'F _ _North Toff l Net Fenestration i'ft2} G E+G Total %f Fenestration � a H / A Max of 20% North South South Nurth East East — West _ South South East Totals East + J " ^wDL aaa,r,+t', +uca exc r.Cus 770 or l.r Ain cltmate Zones z, 4, :::nd 7-15, the performance approach must be used. 2) If total percent of fenestration exceeds 20% including West. Ucing orientations then performance approach must be used. West facing area includes skyligbts tilted to the west or tilted in any di. ection when the pitch is less than 1:12 for Package D only. FENESTRATION PRODUCTS - NEW CONSTRUCTION- ADDITIONS ✓ ❑ Less than 100 ft , ® Less than or Eoual to 1000 W 171r.raatPr 9 nnn #42 A B C D E --- F G H #/Type/Pos. (Front, Left, Reay, Right, Skylight) Orientation Addition's N, S, E, W CFA ` Addition's New Fenestration Area fig "enestration . Area Removed to make way for edition fig' Fenestal tration (D + E) Total % of West Facing Fenestration F/C xI0007o/ Total % of Fenestration2 x100°/0 _ North Toff l Net Fenestration i'ft2} G E+G Total %f Fenestration � a H / A Max of 20% North South Nurth East Wese South South East East East West West West Total nuuluvnb uiat auu cess tnan avtt ox renestratron area are exempt trom the maxim�cm total area limits. See Table 8-2 in RM. 2) If the addition has a floor area equal co or less than 1,000 ft', the maximum allowed Pen. estmtion % may be increased to by the amount of glazing removed in the wall 'hat separates V' c addition from the existing House. See Table 8-2 in RM. 3) If the addition has a floor area greater than to 1,000 ftp, must meet Package 1) requirements. See Table 8-2 in RM. 4) West facing area includes skylights tilitid to the west or tilted in any direction when the pitco is less than 1:12 for Package D_ FENESTRATION PROlDUCI'S: ALTERATIONS Use this table for alterations to an ex;ctino Niilrlinv wlwrP fPnP,+ratinn nrn 1— tc f� ;r A—u *i — I-- .o.,,,.,,sA -A/. eA i.A A B C D '_ ...----��-�------------ F G ----- H -- ------ 1 CFA Existing Orientation Existing Area (ft) Removed Orientati ��n Removed Area (ft2) Propo,-ed Installed Orientation Prop Proposed Installed New Ar='a Toff l Net Fenestration i'ft2} G E+G Total %f Fenestration � a H / A Max of 20% North _Norah Nurth South South South East East East West West West Total Total Total i) wnen ov rt- or more of tenestration area is added to an exist,; bui;ding, then the fenestration must meet the requirements of Package D. The area requirement for the total fenestration area t,:)r thi- whole building, including the added feoestration, must not exceed 20% otherwise the Performance Approach must be used. Note: The 511, vvest facing limit is exempt. Se.. Section 8.3.3 in the RM for further details. Residential Compliance Forms March 2005 } K' f).RESIDENTIAE'K.ITCHEN LIGHTING WORKSHEET WS -SR 1 c Project Title . Date At least 50% of the total rated wattage of permanently installed luminaires in the. kitchen must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire TIM Hig Efficac ?. Watts x Quantity– li!-Lij Efficacy Watts or Other Watts Yes No ❑ — x = _. _ . G% or Yes o No o x = or Yes o No o x = __. or Yes o No o x _ = or Yes o No o x = or T_#01• e • B: / COMPLIES I F A? B Yes o' No 0 r l'LE „ tESiDEN' IAL -'11U ] IEN I;'IGI�TIN.I :WC�RKSJHEE'. .:....:. D ate .. i.i ... anon for'all luminaires to be instaUed.in'kitchetis: : Kitchen ligtitong,5cheaule::=Piovide tfie following iitiforin r ,,..: ..:................. . :.: y ,..: ,,....... :. - yw .....:....:... 8l► .. .H ' Effic.c is � ' Quadtity'. ���_``�:�,.1,.--.---•- Watts vspr ; �I;uintnaue .'37 - r + 'CSU ".Yes:<'• 18 6 48 _ a N x X. .. – `. 'Total: A.. 1�'i< g• ....100 COMPLIyS IFA > : Residential Compliance Forms Mareb 2005 MANDATORY MEASURES CHECKLIST:RESID NTIAL �Pa� D_ MIS -1R Mote: i,owiise residential buildings subject to the StandWt thull et Fusin these rneasu!,v3 regardlv_�s of the ec.mpliance approach used. [teens marked with an asterisk (') may be superseded by more stringent compli,utce nequir..ments listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents. rhe features ached shall be considered by all parties as minimum component performance specifications for the mandatory meas::: es wbethcr &-y are show n elsewhere in the documetty or on this checklist only. Instructions: Check or initial applicable boxes when completad or enter NiA if not applicable. DESCRIPTION T� DESIGNER ENFORCEWNT IBuildint Envelooe Measures: ' §150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation rratnufacturor's labeled 11 -Value. ° § 150(c): Minimum R-13 watt insulation in wmid famed walls or equivniont ! YF'ar„ir in metal i. arae walls does not g& to exterior mass walls). _ • § 150(d). Minimum R• 13 raised floor insula:ion �rt franiud ;loon. Slab edge insulation - water absorption rate no ipaidi t than 6.3%, wrist vapor trwrwn -Sslon i.ila no eater than 2.0 pgfmrech. §118: irisu'tation speuifwd or iastall.ed meet; insulation yusVty standards. Indicatetype stul form. i §116.17: Fenestration Products, Exterior 1'xurrz, rayl In iltratim/EetiluationCon+sols 1. Doors ars; windows tietween conditiorwd and unconditioned space-~ designed to limit i;ir leakage 2. Fenestrotiou.productg (except fieid•fabriuxud) havr, lithet with certified V -"'actor, oertiFied &tier Beat I Gain Coefficient (SHOC'), and infiltration oerhfirntioa j jl f 3. Exterior doors and windows weather strilh,,ad; all joints •rad penetrations caulked and scale d. I i § 1S(►(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with § 151 meets Cotnnrission quality standard;. j IS0 i ,� e (): btstetllation of Fireplaces, Decoral�ve Gr.s Apylianees ctrl Gas L,og:, L Masonry cv; {'act uybtult firzplat ev have: a. Closeable metal or glass door jl I h Outside air-intake with damper and •:onuol c. Fluo damper and control 2. No otmtinu =i burning gag pilot lights allowed. Space Conditioning, Nater Rearing and Plumbing System Measures: §110-§ { 13: H`JAC equipment, water heaters, showerheada turd fa�icets rettilied by'!he Camniission. i I.T(h): Heating andlot cooling loads calculated in ri"ordatwa with ASIfk.kE, SMACNA. or .ACCP.. § 1SU(i): Setback tltctTnostut un all applicable heating end/br c�,rling systems . �� § I Wj): ?ipe and tank ins-Wacion 1. Storage gas water heaters rated with an Gnergy Factor legs diati 0.58 must i>J exterritily tvmpptd with i in:tlation having an installed thermal n;sistance of R-1'2 or greaser. j 2. First 5 feet of pipes closest to water heater tank, non -roc r:'u[upn6 sySte1,15, ;muluted (It -4 o; greater) , fired storage tanks, or other indimet h a, water tarifa hates R-12 3. Hack -up tanks for solar stemun /A I 1 external insulation or R-lh cumbi wd intumaUcxterrui insulation. I i 4. All buried or exposed piping irisulated in iecirCulnt ng .actions of bet :r•a:or sy9terns. S. Cooling sy_+tem piping below SS° F insiarted. 6. Piping imulated between heating sour.x and indirect hot writer task. Compliance Fortes August 2001 A-5 INIANDAT®RY MEASURES CHECKLIST: RESIDENTIAL, (P&e 2 dote: Lowrise residential buildings subj�t t m the Stsnd&r'ds must contain these mast as regardless of the compliance approach used. Items marked with an asterisk (i) rn�r be superseded by more stringent compliHttc+ regwrenients listed on fire Certificate of Compliance. When this checklist is incorpomt--A into the perar t docunlents, the features notsd shall be considered by all parties as minimum component perforraance specifications for the mandatory measures vwhethcr thev we shown elsewhere in tale doewricrits or on this checklist only. instructions: Check or �.ttitial applicable boxes when completed or enter K/A if not applicable. Compliance Forms August 2001 _. __� S Or.►�i�.T 1V 1✓n C:1V i'i.Ji��..ua�ia�.�_�.�.-� Space Conditioning, Water Heating and Piu robing System Measures: (continued) _ o § I50(m): Moss and Fans •I 1. All ducts and Ipletztrvs installed, sealed and ueramed to rneet tete requiicr -wni ol'the 19913 t'TvIC Sectica9 y; l' i 603, 604, and Standard 6-3-. ducts :.nstilatsd to a minim'.trn installed level of 1d-4 -2 or enclosed er>ttre!y "A 1 ethersystem f iconditioned space. Opettin*s shall bo scaled with mastio, tap., aems<;1 sca!ant, nr ether duct i sese>'i thatnteets the applicable rnquiremetsts of C 1, l8 i, U . 1$ SP., tic UL i g r'8. if niastit or tepee used w olreitiiW greater than 1/4 inch, the ownbirwtic?n of nwstu> rung vitlwr r+icsn or rape shall' ba usod. Building cavities shall not be used for conveying c<+tldrtioned airints Mid seams of due:. system$ and their corGpottena shit,} not be sesled .vith cloth baoi, ruhtrcr a llrssive duct types unless such taTv 1; ,Ijed ir. combination with trastic and drawberd:, i 2. Building cavities, support platforms for air handle's, and piPnurns detired or corstruue<'. u idi materials t other than scale} sheet metal, duct board ur flexible riuct shall not be usi-A 1',)r --onveying conditioned I �� air. Building cavities and support plutfo<ms may certain dusty. t)uctr•. iosialied in cavities and support i platfoana shall not be cont?ressed to cares reductions ul urn gross-secdurral dice of the dile?: I 1 3. joints, and seems of duet n s;em- and thr_r. cc,mponents :;hall not bt sealed c,ith olodr back : ubtxr _s-,t adhesive d" -t tapes unless ch We is +,sed in. combituition tvi.th nutic rsattd dnrtvbattds. 1 d. Exhaust fan systems have beck draft or uutoinatie dampers. 5. Gravity -.emilating systems serving c<)rdriioned spuoa love rithzr t+Jto naris or readily ucc"siblt, r manually operated dampers. S. Protection of trr_.rulation. Inyuiation snail be lnoieot,;d from .-IRmagt, uv;luding tim duc to surdight, tnoiAure, equipment tnainterance, end wind bet nol &.--tad to the following: (nsu!itiov erpb'.;rd to weather shall be suitable for outdone service e.g., protadted by elurrtiinun, sheet metal, pau;tcd canvds, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating Thai is water retardant anal provi,ics shieldtn[t from solar rudia6on t'+at.can cause dar:.radation of the material. § 114: Pool and Spa Heating Systems and Equipnurrt. 1. System is certified with 78% thermal effieietiev, weatherpro•.fnpet+,ting itisutwtioris, no el"tric resistance heating and no pilot sight. '2. System is installed with: a. At least 36" of pipe t.ctwsen filter anal heater• for tinvie solar hentirrg. ! b. Cover for outdoor pools or outdoor i 3. Pool s; -stem has directional inlets attd it cin;ulritior. primp time switch. § 115: Gas fired central ftuniiacm, pool htau;rs, spa healers or household ,.}king uppliaol;as lu^vei no continuously bumin •iui h r:. xe ,tion: !Von-eiectricai cooking app:ia; ces withPit(), 50 § 118 01): Cool Roof material meet specified ori=aria Lighting Measures: § 150(k)l.: Luatinairea far general lighting in kitchons shall have lamps with „r, efticucv'of Jif turnetWwatt or greater for general lighting w.. kitchens. I'h a general lighting shall be cuu.rvlled by d swir:7 nu a reodil> accessible 1,ghtingoontrol F2nei at an entrarice to the kitchen ier at least and hym ve with lanys .vith ern § 150(k)2.: Rooms with a shower or bathtub must have tidwa effmaey of 40 luumns/watt or greater switched at the dnirdnuc tc- the room .t: one of the alwn',at,ves to t requirement allowed in § 150(k)2... end ipcnndescent recessed ceiling fixruc, an- IC (aisalation cover'. �3 1 approved. �__..__yi Compliance Forms August 2001 _. __� S