Loading...
0004-022 (SFD)111 . itx LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Div,Sion 3 of the Business and Professionals Code, and my License is in full forc and effect. License # Lic. Class Exp. Date 746198 CIO 02/28/2( –Oe Signature of Contract00000,10 W� or ' —•^� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors,.to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will.maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier VILLANOVA INS, CO Policy No. WC 112-31206 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the ork for which this permit is issued, I shall not employ any person in any m ner so as to become subject to the workers' compensation laws of Califor I and agree that if I should become subject to the workers' compensatio rovisions of Section 3700 of the Labor Code, I hall forthwith comply with t to provisions. /Date:j�` Applicant 0 - /Warning: OF to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT 'Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his l application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall; indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I' agree to comply with aql City, and State laws relating to the building construction, and hereby author a representatives of this City to enter upon, the above-mentioned property f r inspection purposes. f �IaBture (Owner/Agent) Date "fid BUILDING PERMIT PERMIT# DATE VALUATION LOT 0'� TRACT rig) $13.1,341,40 f JOB SIE APN ADDRESS 90-700 CAIJX GUAYIl'.tA;S 7(;94 003 k OWNER i� _ 1 CONTRACTOR/ DESIGNER/ EN &NEER DURM90 A & M CONMRUCTIOM P.O. BOX 366 '78.070 Cly LE CADIZ LA Q'LT_KI'A CA 92253 LA Q0WA CA 92253 (760)564-'4832 =16 626 USE OF PERMIT S NOIZ FAMMY DWRI13N(3 SIM -PERMIT DOF:.S 140T 114CLUDE HL,OC KWALLs OR POOL TRACT CONSTROOTION 2119b.00 OF QA.RA0E1CAR_PORT ($ij 1p90.00 5 r. WOOD PENCE 200.00 LF 1 sIrl1i'(A231<U CL??s'rOle CONS"IRUC' 7(w 131,341A0 PERUTT M, SUMMARY C-11STRUCTION FEE 101 -OW-418-000 17:'11,30 PLAN CHECK FY;E 101-000-4313-318 $630.56 MECHAMC.AL ME 101.000.421.000 $71,00 I:I ECTWCAL FEE 101-000-420-000 $156.93 PI.1).MBTWO ME 101 -Opo -419.000 $124.00 STIWNC3 MOnaN, FEE - R.]: ND 101-000-2411-000 E13.19 CIRA17INO "XI.. 101.000.423.000 320,00 DEVELOPER IMPACT Ftp $1,903.00 � PRECISE PLAN 1 Ol-000.441-345 $10koo PEE DEPOSIT 101-000-439-318 u$e50.Ofi A, K t 9T.113 -TOTAL CONKRUC:TIOM AN -D PT(AN Gin -CK $3,795.12 "8 PR1's'•P?.W 1��'.1:'1� • 250.00 e Y O g A RECEIPT DATE I BY DtrRA7yINSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Forms & Footings ()_ Underground Ducts Ducts Slab Grade 04 7 Return Air Steel Combustion Air Roof Deck O.K to Wrap _�� - O d �LT Exhaust Fans F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath _ Final ��IL �� IL BLOCKWALL PPROVALS Final POOLS -SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground P(bg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection S' 7 Encapsulation Gas Piping Gas Test _ �. S Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: Building Address ! Owner Twi u�,`ctcv PA I D t 0 4 P.O. BOX 1504 AAPF"AdAfte ONLY � 78-495 CALLE TAMPICO B✓ �LA QUINTA, CALIFORNIA 92253 0� LA QUINT, mounts 0 3 4o co Address j'/� City l.. C.]C_ M7,–,.3 0 Aaares,�4 4 I d ✓ State Lic. } City � & Ciassif. Y $ / 8 / Lic. # 4,p Arcn., tngr., Designer Address City/i (Zip (State ' Lic. # NSED CONTRACTOR'S DECLARATION I hereby affirm that I icensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Business and Professions Code, and my license is�-in,JfulI force and effect. ee u a/ Nd OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License law for the following reason: (Sec. 031.5.8usiness and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500). I I I, as oner of the property, or my employees with wages as their sole compensation, will do the wowrk, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden Of proving that he did not build or improve for the purpose of sale.) I 11, as owner of the property, am exclusively contracting with licensed contractors to con. struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) it 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company n Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of alfplicant Date Mailing Address City, State, Zip BUILDING: TYPE'CONST. /� / OCC. GRP. A.P. Number 761- -0 (b K1 ' ©d 3 —5; Legal Description L56 Project 6 C Project Description 5 r `J Sq. Ft. �l p QNo. No. Dw. Size 4 1 V Stories Units News. Add O Alter O Repair O Demolition ❑ r Estimated Valuation PERMIT �/ tG AMOUNT Plan Chk. Dep.. d Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION 78-495 CALLE TAMPICO LA QUINTA, CA 92253 (760) 777-7075 APPLICATION FLOOD PLAIN DEVELOPMENT PERMIT BUILDING SITE LOCATION FLOOD ZONE 'AO"- DEPTH 1 (r �C COMMUNITY- PANEL NUMBER 060709 0005 B Map Revised: 8/19/1991 APPLICANT INFORMATION SECTION APPLICANT NAME APPLICANT D ,7 oQ (71�,LL ADDRESS IMAILING ADDRESS, NOT THE BUILDING SITE) DAYTIME TELEPHONE NO. INSTRUCTIONS 1. A Flood Plain Development Permit is required by LQMC Section 8.11.040(A). The Applicant should complete the Applicant Information portion of this application and submit it to the Engineering Department along with the required documentation noted hereon at the same time the Precise Grading Plan is submitted to the Building and Safety Department for plan checking. 2. Documentation required for STEP 1 OF 2 APPROVAL prior to receiving clearance for Building Permit issuance • Copy of the proposed Precise Grading Pian for review and.approval containing all'information required by the checklist shown on the back of this application. 3. Documentation required for STEP 2 OF 2 APPROVAL prior to receiving Flood Plain Development Permit approval. Note, this approval occurs after forms for the lowest habitable floor are set and before the Building & Safety Department authorizes foundation construction. • Submit a completed FEMA "Elevation Certificate" form to the Engineering Department. • Submit 95% relative density soils compaction certification to the Engineering Department. C' STEP 1 OF 2 APPROVAL STEP 2 OF 2 APPROVAL. The Precise,Grading Plan submitted for this application has been All requirements have been satisfied. This Flood. Plain reviewed and found to contain all data required to satisfy the Development Permit is approved. requirements of LQMC 8.11 The proposed dwelling is eligible to receive a building permit upon satisfying all other Building & Safety Department requirements. pU Iz o0 AUTHORIZED SIGNATURE D&E AUTHORIZED SIGNATURE U DArE La Quinta Engineering Department La Quinta Engineering Department FOBO REV -1 11/99 J.. - CHECKLIST FOR PRECISE GRADING PLANS IN "AO" FLOOD ZONE 1.. Prepare Precise Grading Plan in accordance with Checklist for Precise Plans and the following additional items. 2. All elevations shall employ the NGVD-29 convention. X3. Show and label elevation of "Highest Adjacent Grade" next to the building footprint. This refers to the highest existing natural grade next to the proposed building prior to constructing the elevated the building pad. �4. Show and label the "Highest Existing Elevation on Lot' ,A5. Show and label the "Lowest Habitable Finished Floor Elevation". Note, this elevation shall be at least ONE FOOT higher than the "Highest Adjacent Grade" elevation. 6: The following grading note shall appear on the plan: All fill material placed under the structure shall be compacted to ninety-five percent (95%) relative density. F090A 10!88 PUBLIC WORKS CLEARANCE LETTER _ FOR CUSTOM HOME LOTS .. e6_-T-oCL Dear Builder:. . Prior=t ssuaoce-o a building permit, you will be required to obtain clearance from the Public Works Departm nt for one, or more, of: he following: " 1.. Verification that rough grading is complete, and the pad elevation certifications prepared by a licensed surveyor, or engineer, are on. file in the Public Works, Department. 2: Verification that infrastructure improvements and other 4e u'ired`tract -improvements'.- are improvements are complete, or sufficiently advanced to warrant building permit issuance '= z '3. Prepare an engineered grading plan that provides for on -lot storm water retent'oni- and have it checked -and approved by the Public Works Departments ,.. • Tract 26524 (Estancias) • Tract 26769 (Mountain View Estates) a . 4. Prepare an engineered grading plan thatprovides for building pad, grading in accordance with the existing soils report and tract grading. plan, and. have checked and approved by the Public Works Department. • Tract 28034 (South Valley Estates) . FOR INTERNAL USE BY PUBLIC WORKS DEPARTMENT .x F:IPWDEFnDOCS%FORMSWWCLEARANCE LETTER.ss ': ` Notice: Document Cannot Be Duplicated Date 6/5/00 No. 20523 Owner NameCraiR Durninp, Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 760-771-8515 CERTIFICATE OF COMPLIANCE 1 Jurisdiction I ( No. 50-700 Street Calle Guaymas city La Quinta zip 92253 APN # 769-066-003 La Quinta Permit # 0004-022 Log # Study Area Tract # Lot # 36 Square Footage 2198 Type of Development Single Family Residence No. of Units 1 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 2.05 X 2,198 or $ 4,505.90 the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued Fees Paid By CC/Palm Desert National Bank/Rick Morris Telep4>t`one Name on the check By Dr. Doris Wilson Superintendent .. Fee collected /exempted by Mary Ann L. Bora Payment Received $4505.90 Check No. 081064 Signature NOTICE: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to collect them on. the District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting Apr -05-00 09:25am From -MEREDITH & SIMPSON dba PRESSURE COOL RECORDING REQUESTED BY: Fidelity National Title Company Escrow No. 40585 -CB Tide Order No. When Recorded Mail Document and Tax Statement To: Mr. and Mrs. Craig Durning 78625 Saguaro Road La Quinta, CA 92253 7603427576 T-413 P.02/02 F-327 05/20/1999 08:eOA Fee:6.00 Page 1 of 1 Doc T Tax Paid Recorded in Official Records County of Riverside Gary L, Orso Assessor, County Clerk & Recorder 1 111111 II III IIIII 11111111 Illllllllillllll 1111111111111 1 M S V PAGE ISIZE I OA I PGOR .,,OR &.7 mEc. A R L CODY LONG REFUND 14016 EXAM GRANT DEED °r""`'c ADUvr Ins -2 ulrw rvi% �1 The undersigned grantor(s) declare(s) Docum„ntary transfer tax is 557.75 [ X I computed on full value of property conveyed, or [ I computed on full value less value of liens or encumbrances remaining at time of sale, ) Unincorporated Area City of La Quinta 9 FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, A & M Construction, a Limited Partnership hereby GRANT(S) to Craig Durning and Jeanne Ann Durning, Husband and Wife as Joint Tenants the following described real property in the City of La Quinta County of Riverside, State of California: Lot 36 of Desert Club Tract No. 5, as per map recorded in Book 21, as per map recorded in Book 21, Pages 61 & 62 of Maps, in the Office of the County Recorder of said County. DATED: March 17, 1999 STATE OF CALIFORNIA CODUWA QF_A _ , . . of satisfactory evidence) to be the person(s) whose names) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. Witness my ha nd�official All. / / ► /% /I'i�ri W A By I By: ✓' Manuel Abarca yfiiCfAL SEAL GERALD T. CRNICH Q COMM. 01096287 C Notary Public • California b . RIVERSIDE COUNTY W j My Commisilon Expplres hPFC;L 28, 201)0 MAIL TAX STATEMENTS AS DIRECTED ABOVE FD -213 (Rev 7/96) GRANT DEED '* Certificate of Occup City o f L a Q uin ta oncy Building and Safety Department This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code, certifying that, at the time, of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING' ADDRESS: Use Classification: SFD Occupancy Group: R3 Owner of Building: DURNING ®© 507700 CALLE GUAYMAS Bldg. Permit No.: '0004-022 Type of- Construction:. VN Land Use Zone: RL Building Official Address: P.O. BOX 366 City: LA QUINTA, , CA 92253 By: STEVE TRAXEL Date: 11-27-00 POST IN A CONSPICUOUS PLACE Me OSladden Engineering 6782 Stanton Ave., Suite E, Buena Park, CA 90621 (562) 864-4121 (714) 523-0952 Fax (714) 523-1369 39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893 Fax'(760) 772-3895 December 6, 1999 Gary Stark Construction 39-725 Garand Lane, Suite E Palm Desert, California 92211. Project: Lot 36 - Calle Guaymas La Quinta, California Subject: 1997 Uniform Building Code Seismic Design Criteria Project No. 544-9223 99-11-256 As requested, this memo was prepared to provide 1997 Uniform Building Code seismic design criteria for use in the design of the single family residence proposed for Lot 36 on Calle Guaymas in the City of La Quinta, California. The recently adopted 1997 Uniform Building Code contains substantial revisions and additions to the earthquake engineering section summarized in Chapter 16: New concepts included within the 1997 UBC that will be relevant to the design and construction of the proposed residential structure are summarized below. The project site is located within Seismic Zone 4 as indicated on Figure 16-2, the corresponding Seismic Zone Factor is 0.40 in accordance with Table 16-I. The closest and most prominent fault to the project site is the San Andreas fault that is located approximately 12 kilometers northeast of the project site. The San Andreas fault is designated as Seismic Source Type A in accordance with Table 16-U. Based upon the soil conditions underlying the site, it is our opinion that Soil Profile Type Sp (which is described as Stiff Soil Profile within Table 16-J) is the most appropriate soil profile type for this project. The remaining seismic design criteria can be determined utilizing the information summarized above and the applicable tables within the 1997 UBC. The various seismic design factors are summarized on the following page: r i - December 6, 1999 -2- Near -Source Acceleration Factor - N� = 1.0 (Table 16-S) Near -Source Velocity Factor - N,, = 1.1 (Table 16-T) Seismic Coefficient - C� = 0.44Na (Table .16-Q) Seismic Coefficient - C,, = 0.64Nv (Table 16-R) If you have questions regarding this letter, please contact the undersigned Respectfully submitted, SLADDEN ENGINEERING Copies: 2/Gary Stark Construction Project No. 544-9223 99-11-256 Slodden Engineering Brett L. Anderson 00 No. C 45389 Principal Engineer Exp. 9-30'-2002 Letter/pc s rglF0): r& Eo��\P Copies: 2/Gary Stark Construction Project No. 544-9223 99-11-256 Slodden Engineering TITLE 24 REPORT Title 24 Report for: Durning Residence Calle Guaymas La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 CITY OF 1A QUINTA DEPT. BU�APPROI\U/C-fjoN DING & SAD Job Number: CNNS FO L7:� DATE L BY - DATE Date: 3/2/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. I _ EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 1 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load- Summary 1 2 3 6 8 15 17 EnergyPro 3.1 - By EnergySoft Job Number: User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Durning Residence 3/2/2003 Project Title Date Calle Guaymas La Quinta Project Address Building Permit # Insu-form Inc. (760) 324-2046 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,515 fl? Average Ceiling Height: 9.6 ft Total Conditioned Slab Area: 2,515 ft2 Building Type: (check one or more) Single Family Detached ❑Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FENESTRATION Shading Devices Type Orientation Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Hollow Metal Door None 0.581 Exterior Door R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof Solid Wood Door None 0.387 Exterior Door FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (West) 20.0 0.87 0.70 Bug Screen 0 ❑ ❑ X❑ Right (South) 24.0 0.60 0.69 Bug Screen X❑ ❑ ❑ 0 Right (South) 48.0 0.55 0.65 Bug Screen X❑ ❑ ❑ 0 Right (South) 12.0 0.71 0.63 Bug Screen 0 ❑ ❑ 0 Rear (East) 20.0 0.71 0.63 Bug Screen 0 ❑ ❑ X❑ Rear (East) 96.0 0.55 0.65 Bug Screen 0 ❑ ❑ 0 Rear (East) 63.0 0.60 0.69 Bug Screen 0 ❑ ❑ 0 Front (West) 21.8 0.60 0.69 Bug Screen X❑ ❑ ❑ Q Front (West) 25.0 0.71 0.63 Bug Screen X❑ ❑ ❑ X❑ El El El ❑ ❑ ❑ ❑ El El El El Run Initiation Time: 03/02/03 22:38:32 Run Code: 1046673512 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 18 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Durning Residence 3/2/2003 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Split at Primp 8.00 HSPF Ducts in Attic 4.2 Setback Bedrooms Split -Heat P, imp 8.00 HSPF Ducts in Attic 42 Sethack ruing Zane Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Heat Pump 12.0 SEER Ducts in Attic 42 Setback RPdrnnms Snlit Heat Pump. 12.0 SEER Ducts in Attic 42 Setback I M g 7nna WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value PRODU CH EE ER Storage Elec. Standard 1 15,358 50 094 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: >�Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-form, Inc. Address: - o• C 6041 Address: 68-255 Corta Road .PAUM 6MLA� e • Cathedral City, CA 92234 Telephone: - Telephone: (760) 324-2046 Lic. #: —Z&2K;'0WE303Jm (signature) (date) (sign E,ur) (date) Enforcement Agency Name: Title/Firm: _ Address: Telephone: I EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: PageA of 18 1 Certificate of Compliance: Residential (Addendum) CF -1 R _Durning Residence 3/2/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System 'Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 869 sgft Covered Slab Floor, 3.50" thick at Bedrooms HIGH MASS Design(see C -2R) - Verify Thermal Mass: 150 sqft Exposed Slab Floor, 3.50" thick at Bedrooms The HVAC System "Living Zone" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 317 soft Covered Slab Floor, 3.50" thick at Addition HIGH MASS Design(see C -2R) - Verify Thermal Mass: 419 soft Covered Slab Floor, 3.50" thick at Living HIGH MASS Desiqn(see C -2R) - Verifv Thermal Mass: 760 soft Exoosed Slab Floor. 3.50" thick at Livinq HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field Run Initiation Time: 03/02/03 22:38:32 Run Code: 1046673512 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 18 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowdse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X 11 50(a): Minimum R-19 ceiling insulation. E] §150(b): Loose fill insulation manufacturer's labeled R -Value. " o§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). E"§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑X § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑X § 150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 18 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (`) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) `§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ❑§115: Gas fired central furnaces, pool heaters, spa heaters or.household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. ❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 18 -' Computer Method Summary [)--Q - X X IX IN F-1 ❑ ❑ ❑ ❑ ❑❑ F-1 ❑❑ El ❑ El.R-m ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ElI F -1B ❑ ❑ ❑ ❑ El Q 0 F-1 M (Part 1 of 3) C -2R .Dumirnesidence .R3.8Roof(R.38.2xJAJ- .R-2LWalLV- 21.2x6J.6.) R21_WN-alL(W21.2x6.16) 31_2/_2003 Project Tie -Cal le_G_u aymas-l-a_Quiata Solid- WLood_QQ01 R2-WalL(_AL2.1-2x616.) Date Project Address 3.8Rooi(R..3E_2x]416-) Building Permit # Insu-Jo-JoInc. (760)-324-2046 Plan Check/Date Documentation Author Telephone C01]]jOLLtel_Ipe10ln]a11CP 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Existing+Addition Budget Adjustment Space Heating 3.90 2.49 1.41 Ratio F: 2198 / 2515 = 0.874 Space Cooling 36.83 44.07 -7.23 Budget Adj: 0.874 X ( 74.71 - 58.57) = 14.11 Domestic Hot Water 11.33 19.60 -8.27 The budget shown to the left has been increased using Totals 14.11+ 52.07 = 66.18 66.16 0 02 this Budget Adjustment based upon Existing building information shown on the C -2R which follows this form. GENERAL INFORMATION Q Slab Floor Conditioned Floor Area: 2,515 Floor Construction Type: ❑ Raised Floor Building Type: Single Fam Detached Building Front Orientation: (West) 270 deg Total Fenestration Area: 13.1% Number of Dwelling Units: 1.00 Total Conditioned Volume: 24,131 Number of Stories: 1 Slab Floor Area: 2,515 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .Bedrooms ?019 _9,121 -0A1_ Sleeping- _Sleep.ingS.tat_ _2 _n1a .Living_Zo.ne 1 49.6 14.960 -0_5.9_ Living _I ivingSiat_ _2 _n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Wall- 140 .0_059 _2.70 20 Wall --X16.._0.0.5.9 18.0_ _90_ Wall- 2.4.0. 0_0.59 9.0_ _90 .Door __2.0 -0-58-1- 90 90El.hollow-M.etaLaoor .Roof 1..019 0028 0 t Wall_ 170 0_05.9 0 -90❑ WaIL_ 84 0.0.59 9.0 90 Wall- -AZO 0052 18.0 90 .Roof_ 317 01028_ ^0 0 Wall- 229_ _0._059 _2.Z0_ -90_ .Door 4. 0.08Z -27_0 9.0 Wall_ 2Q0 0 Q59 0 99_ Wall- --257- 0..059_ _90 `90_ -Wall -321 0..0.52 t80 90_ Roof 1.,129 0028_ 270 0_ [)--Q - X X IX IN F-1 ❑ ❑ ❑ ❑ ❑❑ F-1 ❑❑ El ❑ El.R-m ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ElI F -1B ❑ ❑ ❑ ❑ El Q 0 F-1 M R21.._WN_aiL(W21.2x616) .R2LWNaIL(W-21-2x6 16.) waII-.VlLzL 16) .R3.8Roof(R.38.2xJAJ- .R-2LWalLV- 21.2x6J.6.) R21_WN-alL(W21.2x6.16) R --Z1 Lall (_WM21.2x6J6a R-38Roof (R R 9Y14.16) R-21 Wall (121.2x616.) Solid- WLood_QQ01 R2-WalL(_AL2.1-2x616.) R-21 Wall (W,21,24,16)- W 21 2x6 16)Wall- R21 WalL(W 21.2x6.-16.) 3.8Rooi(R..3E_2x]416-) Location / Comments Bedrooms Bedrooms Bedrooms Bedrooms Bedrooms .Addition .LivingZone EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 18 1 Computer Method Summary (Part 2 of 3) C -2R Durning Residence 3/2/2003 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments _'L V_Kindow--Er_ont---- Lesq _20_0 _0_8.7_0_ 010 _2.70_ _90 Double -Mil -Uncoated -Default- _B.edroorns 2 Window Right (South) 24.0 0.600 0.69 180 90 Mtl Thermal Brk Unctd Default Bedrooms 3 Window Right (South) 48.0 0.550 0.65 180 90 Double NonMtl Clear Default Bedrooms 4 Window Right (South) 12.0 0.710 0.63 180 90 Mtl Thermal Brk Unctd Default Bedrooms 5 Window Rear (East) 4.0 0.710 0.63 90 90 Mtl Thermal Brk Unctd Default Bedrooms 6 Window Rear East 16.0 0.710 0.63 90 90 Mtl Thermal Brk Unctd Default Bedrooms ZWindow 2.0 Rear (East)_ 48.0 0.550 0.65 90 90 Double NonMtl Clear Default Addition 8 Window Rear (East) 48.0 0.600 0.69 90 90 Mtl Thermal Brk Unctd Default Addition 5 Window Front (We -q 9.8 0.600 0.69 270 �Q Mtl Thermal Brk Un_c Default Living Zone 1Q Window Front _(West) 12.0 0.600 0.69 270 - 0 Mtl Thermal Brk Unctd Default Living Zone 11 Window Front est) 25.0 0.710 0.63 270 90 Mtl Thermal Brk Unctd Default -Livdng Zone 12 Window Rear East 15.0 0.600 0.69 90 90 Mtl Thermal Brk Unctd Default -Living Zone _1.3. Windom-Rear---(Ee.st X8.9_ 0_550 0 65 90_ _90 Double RoaMtLCle.aLD-ef.ault_ -Living-Zoll INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 8.0 1.5 2.0 0.1 2.0 2.0 8.0 3.0 2.0 0.1 2.0 2.0 3.0 2.0 2.0 0.1 2.0 2.0 2.0 1.0 2.0 0.1 2.0 2.0 4.0 4.0 2.0 0._1 2.0 2.0 8.0 3.0 2.0 0.1 2.0 2.0 8.0 3.0 2.0 0.1 2.0 2.0 1.8 5.0 2.0 0.1 2.0 2.0 6.0 1.0 6.0 0.1 6.0 6.0 5.0 5.0 2.0 0.1 2.0 2.0 2.5 6.0 2.0 0.1 2.0 2.0 8.0 3.0 2.0 _ 0.1 2.0 2.0 Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:9 of 18 1 Computer Method Summary (Part 3 of 3) C -2R Durning Residence 3/2/2003 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN PERIMETER Minimum F2 Insulation Type (furnace, heat Area Thick. Heat R -Val. Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments .C9nre_t"uvyweigh_ _8.6.0 _3..50 _28. _0_18. nla —2 .BedroomsJ_S1ab on Grade Concrete, He v weight 150 3_50 28 0_98 n/a 0 Bedrooms / Slab on Grade Concrete Heavyw_Cght — 317 3.50 02 0.98 n/a 2 Additi n la�on C Concrete. Heavyweight 419 3_50 28 0_98 n/a 2 Living Zone / Slab on Grade Concrete-Keavy_weigbt— 07 0 3.50 Z8 0.98 n/a 0 Living Zone / Slab nGrade- LOSSES HVAC SYSTEMS Heating Equipment Minimum F2 Insulation Type (furnace, heat Type Length Factor R -Val. Depth Location / Comments Slah.Peri nmeter 36 0,76 0.0 0 Bedrooms Slab-P-erimeter _24 0,Z6 —0-0 0 bedrooms Slate Perimeter _ 2 0.76 0.0 0 Addition S.1ab_2er.imeter 38. 0.26 --0-0. 0 Living -Zone S.Iab_Eerimeter 140 0.76 00 0 Livingon HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments -5 lit Heat Pump 8.00 HSPF Ducts in Attic 4.2 Setback BeSl�r oms Split Heat Pump 8.00 HSPF Ducts in Attic 4.2 Setback Living Zone Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Heat Pump 1 EE �UCtS in Attic 4.2 Setback Bedrooms Split Heat Pump 12.0 SEER Ducts in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A O SMITH WATER PRODUCTS i"r ge Elec Standard 1 15,358 50 0.9A_ n/a n/a -EEFI=52 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 03102/03 22:38:32 Run Code: 1046673512 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:10 of 18 Computer Method Summary (Addendum) C-2R -Durning Residence 3/2/2003 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aciencv determines the adequacv of the justification, and may reject a building or design that otherwise complies cased on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System 'Bedrooms" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 869 sqft Covered Slab Floor, 3.50" thick at Bedrooms HIGH MASS Design(see C -2R) - Verify Thermal Mass: 150 sqft Exposed Slab Floor, 3.50" thick at Bedrooms The HVAC System "Living Zone" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 317 sqft Covered Slab Floor, 3.50" thick at Addition HIGH MASS Design(see C -2R) - Verify Thermal Mass: 419 sqft Covered Slab Floor, 3.50" thick at Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 760 sqft Exposed Slab Floor, 3.50" thick at Living HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field I EnergvPro 3.1 By EneravSoft User Number: 2655 Job Number: Paae:11 of 18 1 Computer Method Summary (Part 1 of 3) C -2R _Durnin slrience Tifie 31220Q3 Date Project -Cal. e_G_ua_y_ma.s_La_0 u.i nta Project Address Building Permit # 1as_U-401M,Jac (760) 324-2046 Documentation Author Telephone Plan Check/Date Computer�etformance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 5.72 4.13 1.59 Space Cooling 40.55 49.74 -9.20 Domestic Hot Water 12.30 20.84 -8.54 Totals 58.57 74.71 -16.15 GENERAL INFORMATION Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 2,198 Single Fam Detached (West) 270 deg 1.00 1 Floor Area Volume X❑ Slab Floor Floor Construction Type: ❑ Raised Floor Total Fenestration Area: 14.6% Total Conditioned Volume: 20,961 Slab Floor Area: 2,197 # of Units Bedrooms 1.019 9.17_1 -098_ living -Z ne 1.1.29 11.79.0 -D-5A- OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt W all- --J 40 0..05.9 X70 90 Wall_ ____U6 005a 180_ _90- -Wall 90_Wall_ 2.40. 0.0.5.9 90. 90 .DooL- 20 0.58. 90 90 Roof- 1,019_ -0-02.8- 0 -0- Wall- 0Wall- 229 0_05.9 170. 9.0 .Door 24 --- 0- 387_ 17_0 _90- -Wall- 0Wall- _200 -0-05a- 0 _90- -Wall- 4Wall_ 3.69 -O-Q59- 9.0_ 90_ Wall- 324 _0..059 180. 90 .B00.f-1.17_9 0029 -270 _0 Solar Gains Y / N Form 3 Reference R2_LVJaIL(W21.2x6J_6) F -21 -Wal 91 9YR 16) R2LVlCall W 212x6.16.) HollovsLMetal.D_oor RR3.8_Booi(1_3.8..2xL4_16) 1R_-ZLWaIL(W.21 2n616.) solid�LVood Door F3-21 Wall M -212x616) JR 21 1lalL(W 21 9c616.) RZLWaIL(W.21..2x616) R-38.Ro0L P_.3B_ 141 Zone Type Sleeping_ Living Thermostat Vent Type Hgt. Area _S1eep.ingStat_ _2 _n/a _I lv ftStat_ _2 _n/a Location / Comments Bedrooms Bedrooms .Bedrooms - Bedrooms B.e.drooms - Living_Zone - .LivingZonP Living -Zone living -Zone -Living-Zone LivingZone I EnergvPro 3.1 By EnergvSoft User Number: 2655 Job Number. Page:12 of 18 1 A 'Comouter Method Summary (Part 2 of 3) C -2R Durning Residence 3/2/2003 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _L Window Ftont_We;t� 20_0_ 0-870_ _OZO_ -2.7.0_ _9.0 Double- ULIn.noated_Default_ _Bedrooms 2 Window Right (South) 24.0 0.600 0.69 180 90 Mtl Thermal Brk Unctd Default Bedrooms 3 Window Right (South) 48.0 0.550 0.65 180 90 Double NonMtl Clear Default Bedrooms 4 Window Right (South) 12.0 0.710 0.63 180 90 Mtl Thermal Brk Unctd Default Bedrooms 5 Window Rear East 4.0 0.710 0.63 90 90 Mtl Thermal Brk Unctd Default Bedrooms B Window Rear (East)- 16.0 0.710 0.63 90 90 Mtl Thermal Brk Unctd Default Bedrooms 7 Window Front (West) 9.8 0.600 0.69 270 90 Mtl Thermal Brk Unctd Default Living Zone 8 Window Front (West) 12.0 0.600 0.69 270 90 Mtl Thermal Brk Unctd Default Living Zone 9 Window Front (West) 2.5.0 0.710 0.63 270 90 Mtl Thermal Brk UncSd Default Livin Zone 10_ Window Rear (East) 15.0 0.600 0.69 90 90 Mtl Thermal Brk Unctd Default -LMn Zone 11 Window Rear (East) 40.0 0.600 0.69 90 90 MU Thermal Brk Unctd Default -Lhtbg Zone 12 Window Rear (East) 96.0 0.550 0.65 90 90 Double NonMtl Clear Default _LiyN Zone INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 8.0 1.5 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 2.0 1.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 4.0 4.0 2.0 --0-1 -2-0 2 Q _ 7 Bug Screen 0.76 1.8 5.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 6.0 1.0 6.0 0.1 6.0 6.0 9 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 2.5 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 2.5 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 13 of 18 i Computer Method Summary Minimum Distribution Type Duct (Part 3 of 3) C -2R burning Residence Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) 3/2/2003 Project Title SARI IJ -gat Pump 8.00_HSPF Ducts in Attic 4.2 Setback BedrQQms Split HeAt Pump Date THERMAL MASS FOR HIGH MASS DESIGN Living Zone Split Heat Pump 12.0 SEER Ducts in Attic Area Thick. Heat Inside Location Type (sq (in.) Cap. Cond. Form 3 Reference R -Val. Comments COn crete, Heavyweight _ _8.6.8. _3_5.0 _28. 0-98. n/a _2. BedcoomsJ_Slab_o.n Grade Concrete Heavyweight 150 3_50 28 0_98 n/a 0 Bedrooms / Slab on Grade _C_Oncr _te Heavyweight 419 3.5Q 28 0_9$ n/a 2 Living Zone / Slab_on r Concrete Heavyweight 760 3_50 28 0_98 n/a 0 Living Zone / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 35 076 0.0 0 Bedrooms Sl.ab_P_etirneter _24 026 —0-0 __0 Be_drooms Slab Peri—ter ___a$ 0 6 2Q 0 Living Zone Slab Be.rimeter _2.90 07_& O.D _0 Living -Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Duct 1 Tank Insul. Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments SARI IJ -gat Pump 8.00_HSPF Ducts in Attic 4.2 Setback BedrQQms Split HeAt Pump 8.00 HSPF Ducts in Attic 4.2 Setback Living Zone Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct 1 Tank Insul. Water Heater Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments S Ii�eatPump 12.0 -SEE Ducts in Attic 4.2 Setback Bedrooms Split Heat Pump 12.0 SEER Ducts in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Rated' Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gam Efficiency Loss (%) Ext. A O SMITH WATER PRODUCTS -EEH-5 Storage Elegy Standard 1 15 350 50 X94 n/a_ n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 03102/03 22:38:32 Run Code: 1046673512 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: —Page: 14 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME • Durning Residence DATE l 3/2/2003 I+ SYSTEM NAME FLOOR AREA Bedrooms 1,019 Number of Systems 1 Heating System Output per System 23,600 Total Output (Btuh) 23,600 Output (Btuh/sqft) 23.2 Cooling System Output per System 22,600 Total Output (Btuh) 22,600 Total Output (Tons) 1.9 Total Output (Btuh/sgft) 22.2 Total Output (sgftlron) 541.1 Air System CFM per System 765 Airflow (cfm) 765 Airflow (cfm/sgft) 0.75 Airflow (cfm/ron) 406.2 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 545 10,347 474 224 9,261 0 517 463 0 0 0 0 0 0 0 0 0 517 463 11,382 474 RHEEM FPFF-024JB 15,558 4,671 5.0 kW Supplemental Electric Total Adjusted System Output 15,558 4,671 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 26.0 of 69.4 of 69.4 of = 88.4 of Outside Air 0 cfm 69.4 of :OGLING SYS 11.0 / 77.4 of Outside Air 0 cfm 78.6/65.1 of Supply Fan 765 cfm 15,521 17,065 32,586 Jan 12 am 109.2 of Supply Air Ducts 1086OF Heating Coil Aux. Heat Coil HROMETRICS 78.6 / 65.1 of 1 V ROOMS 70.0 of Return Air Ducts I Tem 78.6 / 65.1 of . 59.7/58.40F Supply Fan Cooling Coil 765 cfm �% Return Air Ducts 4 Supply Air Ducts 60.3 / 58.7 of 49.8% R.H. ROOMS 78.0 / 64.9 of EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:15 of 18 'Ro6M LOAD SUMMARY PROJECT NAME DATE Durning Residence 3/2/2003 SYSTEM NAME FLOOR AREA Bedrooms 1,019 Rnn I nnn SI IMMORY EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 17 of 18 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Bedrooms Bedrooms 1 545 10,347 474 545 10,347 474 224 9,261 PAGE TOTAL 1 545 10,347 474 224 9,261 TOTAL 1 545 10,347 474 224 9,261 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 17 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Durning Residence DATE 3/2/2003 SYSTEM NAME FLOOR AREA Living Zone 1,496 Number of Systems 1 Heating System Output per System 60,000 Total Output (Btuh) 60,000 Output (Btuh/sqft) 40.1 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 32.1 Total Output (sgft/Ton) 374.0 Air System CFM per System 1,650 Airflow (cfm) 1,650 Airflow (cfm/sqft) 1.10 Airflow (cfm/Ton) 412.5 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS 26.0 of 69.2 of 69.2 of Outside Air 0 0 cfm 69.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,700 29,256 2,958 783 29,479 0 1,463 1,474 0 0 0 0 0 0 0 0 0 1,463 1,474 32,182 27958 32,427 RHEEM FPFF-048JB 31,315 12,580 39,461 7.5 kW Supplemental Electric 25,598 Total Adjusted System Output 31,315 12,580 65,058 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am im Temperatures at Time of 91.5 of . 105.9 of Supply Fan Heating Coil Aux. Heat Coil 1650 cfm k Return Air Ducts 4 Supply Air Ducts 105.1 of ROOMS 70.0 of (COOLING SYSTEM PSYCHROMETRICS (Airstream Temaeratures at Time of Coolina Peak) I 11.0 / 77.4 of Outside Air 0 cfm 78.8 / 66.4 of 78.8 / 66.4 of 78.8 / 66.4 of IIIIIII 61.1 / 60.0 of Supply Fan 1650 cfm Cooling Coil h Return Air Ducts '4 Supply Air Ducts 62.0 / 60.3 of 54.1% R.H. ROOMS 78.0 / 66.2 of EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:16 of 18 ROOM LOAD SUMMARY PROJECT NAME Durning Residence DATE 3/2/2003 SYSTEM NAME Living Zone FLOOR AREA 1,496 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 484 8,326 147 484 8,326 147 129 4,863 Living Zone Living 1 1,216 20,931 2,811 1,216 20,931 2,811 654 24,616 PAGE TOTAL 1 1,700 29,256 2,958 783 29,479 TOTAL 1 1,700 29,256 2,958 783 29,479 EnergyPro 3.1 By EnergySoff User Number: 2655 Job Number: Page:18 of 18