Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-0926 (RER)
P.O. BOX 1504. 78-495 CALLE TAMPICO 44 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY'DE.PARTMENT BUILDING PERMIT Application Number: 13-00000526 Owner: Property Address: 7.8252.:HACIENDA LA QUINTA TIM OKEEFE APN! •- 646-280-003- - - 78.-252 HACIENDA LA 'QUINTA Application description: REMODEL - RESIDENTIAL LA QU"INTA, CA 92253 Property Zoning:. LOW DENSITY RESIDENTIAL Application valuation:. 80000 Applicant: Architect or Engineer,: A) A ------------------ LICENSED CONTRACTOR'S• DECLARATION I herebyaffirm under penaltyof perjury that am licensed under provisionssof'Chapter.9' (commencing,with Section 70001 f Division 3`of the B in d`. o nets Code,.end my License is in full force and effect. License' ass: -B. C27 License Noi:1j►84857 Date If Contractor:, oW NER-BUILDER' DECLARATION 1 herebyaffirm under penalty of perjury that.l�am exempt;from the Contractor's- :State License Law for the fcllowirlg reas6n (Sec. 7031:6;CBusiness and ProfessionsCode: Any city:or.courrty that requires a.permit,to construct, aher,,Improve, demolish,:or repair any structure, prior tots issuance; also requires the applicant for the permit to file a signed statement that he or, she is licensed,pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3,of,.the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged',exemption. Any violation of Section 7031 5 by any applicant for a permit subjects the applicantto.e civil penalty of not.morwthanfive hundred dollars (8500)1:" ( _11 1„as owner (if "the property,, or my employees with wages as their sole compensation, will do the work, and the:structiire, is not intended or offered for sale,(Sec: 7044,'Business and Professions Code: The Contractors' State Uoense,Law does not apply to an+ownerof property who builds or improves thereon, , and who does the work himself or. herself through his or her own employees,provided that the improvements.are,not intended or offered for sale. If,,however, the building or improvement is sold within one year of completion, the owner -Wilder, will have the burderi-of proving that he orshedid not'build or improve for.the purpose of sale;): (_) 1, as; -owner of the property,•am exclusively contracting with licensed-contractors•to constructfhe project (Sec. 7044, Business and Professions. Code: The Contractors' State License Law does,not apply io.an owner of property who builds'or:improves.thereon, and who contracts,for the projects witha contractor(s) licensed pursuant to the Contractors' State License Law.). I am-exemptunder,Sec, , B.&P.C. for this reason Date: _ Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury thatthere"is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Contractor: EDWARDS CONSTRUCTION INC, 51455 DESERT CLUB ,DRIVE LA QUINTA, CA 92253 (760)777-8202 Lic. No.: 684857 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 I WORKER'S, COMPENSATIOWDECLARATION Date: 8/.28/13 NO 2013 I,hereby affirmunder penalty of perjury one of the following declarations: I have,and will maintain a certificate of.consent to self -insure for workers' compensation, as provided for'by Section 3700� of the Labor Code; for the performanceof the work for which_ this permit is issued. I have.and will maintain workers' compensation insurance, as required;by Section3700 of the Labor Code, forthe;performance of the'.workfor which"this'permit'is issued. My workers' compensation insurance carrier and policynumber°are: Carrier BENCffiNARK INS Policy Number WC1914223 _ I certify that; in the perfoimance,of the work for.which thispermit is: issued, I shall not employsany person inany-manner so.as to'bewpeNpOct to the workers' compensation laws of Californisi and agree that, if I.s bac ubj .to the worke��A�provisions' of Section 3700 of the Labor Cod I sh II it omply with 42 Date: Applicant: WARNING: FAILURE TO.SECURE, WORKERS! COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN'EMPLOYER TO CRIMINAL P£NALTIES:AND CIVIL FINES UP TO ONE'HUNDRED THOUSAND DOLLARS (8100,000). IN ADDITION TO THE -COST OF COMPENSATION; DAMAGES AS PROVIDED FORI IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND. ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT' Application is:hereby made to theZirectorof Building and Safety for a permit subject to the conditions and restrictions setforth on this application. 1. Each person upon Whose: behalf this application is made, each person at.whose request and for whose, benefit work is performed under or pursuantto:any permit issued,as a result of this application, theowner,,and the applicant; each agrees to, and shall defend„indemnity. and hold harmless .the City of La Quinta, its officers, agents and employees for any adt.or omission -related '.to the work being performed under or following issuance of this permit. 2. Any permitissuedas'a result of this application becomes null and void if work isnot commenced within 186 days ,from date of"issuance.of-such permit, or cessation of work for 180,days will subject permit.to cancellation. I. certify that :I'have read this application ,and- -. state' that the a ove=inf mation's correct. I agree to comply with all. city and unt ordinances and state laws relatingtobull n trio ,and herebyauthonz representatives of thi `1 enter,upon4he above-mentioned proper y r io purposes. Date: Signature (Applicant or Agent): 'r. LQrmeMn' Appl;ication..Number Permit Additional desc . Permit Fee . . . .. Issue Date . Expiration. Date . . 13--0000Q926 ELECTRICAL -2013 23.83 2/24/14 Plan Check Fee . . .00 Valuation . . . 0 Qty Unit Charge Per Extension 1.00 23,.83'00 ------------------------------------------------------------------------------ LS ELEC FIXTURES, FIRST 20 23.83 Permit . . . MECHANICAL 2013 Additional desc . Permit Fee 23.8.4 Plan Check Fee :00 Issue Date . . . . Valuation_ 0 Expiration Date . . 2/24/14 Qty Unit Charge Per Extension 1.00 11.9200 EA MECH APPLREP/ALT 11.92 1.00 11.9.20O.EA MECH VENT FAN 11.92, Permit PATIO COVER 2013 Additional desc . . Permit. Fee . . . . 9.'5.81 Plan Check Fee 00 Issue Date . . . . Valuation 8.0000 Expiration Date 2/24/14 Qty Unit Ch e.- Per Extension 1.00 95.8.100 EA MISC PATIO.COVER, STD 9.5.81 Permit . . . PLUMBING 2013 Additional desc . . Permit Fee . . 83:44 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date : 2/24/14 Qty Unit Charge Per Extension .6.00 11.9200 EA PLBG FIXTURE/TRAP 71..52. 1.00 11.9200 ----------------------------------------------------------------------------------- EA PLBG WATER INST/ALT/REP 11.92 Permit . Additional desc . . Permit Fee . . Issue Date Expiration Date . REMODEL 2013 70.0.7 2/24/14 Plan Check. Fee . . ..00. Valuation . . . . 0 Application Number .. . . . . 13-00000926 Permit . . . . . . REMODEL 2013 Qty Unit Charge Per Extension 1.00. 48.,6200 LS MISC REMODEL, IST 100 SF 48.62 1.00 21.4500 EA MISC REMODEL, ADDL 500 SF 21.45 --------------------------------------------------------------- Special Notes and Comments - - ---------- ENCLOSE EXISTING ATRIUM. CONVERT TO LIVING SPACE 125 SQ. FT. AND INTERIOR REMODEL.164 SQ. FT. PATIO ADD- PER 2010. CALIF BUILDING CODES. NEW SPA FIRE PIT &:BBQ NOT PART OF THIS. PERMIT. August 12, 2013 2:16:2.0 PM j,j ohnson . ---------------------------------------------------------------- Other Fees BLDG STDS ADMIN (SB1473) 4.00 HOURLY PLAN CHECK 105.0.0 PLAN CHECK, PATIO COVER 94.38 PLAN CHECK, ELECTRICAL 23.83 PLAN CHECK, REMODEL 150.15 PLAN CHECK, MECHANICAL 9.54 PLAN CHECK, PLUMBING. 83'.44 STRONG MOTION (SMI) - RES 8.00 Fee summary Charged Paid Credited Due -------------------------------------- Permit Fee Total 296_.99 .00 --------------------- .00 296.99 Plan Check Total .00 .00 .00 00 Other Fee Total 478.34 .0,0 .00 478.34 Grand Total 775.33 .00 .00 775.33 LQPERMff 'I ' pecb&J - J)Wtj 'tJ 3 -'\ NO.-IrIOAL LAST 1As Bin # Oty 0f La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico R ECEIVED La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Shee. Permit # Project Address:Owner's =-4 Name:7-9 I \ K-- A. P. Number: 7b-29-2 14A41 6^10A LA QUjAIT Legal Description:, A LA QUINTA k . lAddress: '19-2DEVELQP4:N City, ST, Zi;-J� Contractor: Telephone: ? ) Address: Project Description: City, ST, Zip: Tele hone: one: 7-17 - �262' Eliza= U L^. Lwv State Lic.#: City Lie. #.. Arch., Engr., Designer:&V56141 t(lin UIEW Co U E-d2AID! N—Al I 11'N 6 S Address: qq�161 CL"6K' City., ST, Zip: q?Z3� Telephone:. Il4.915- 7q I ... . ....... . . . . . . . . . . . . . . . . . . Construction Type: Occupancy: State Lie. #: Proj ect type (circle one): New Add'n Alter Repair Demo Name of ContactPers n. 0 Sq. Ft.: # Stories: 9 Units: Telephone# of Contact Person: 766 Estimated Value of Project: (A(l 6100 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Reqld Rec1d TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount i Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees pb�")-5 K Be- 1-5SOW glo- -1--17 ti 244341 p(mris P19"I To. 1 5SUG XFI C*6 C) T ,,_ __. 71-780 San Jacinto Dr. Ste. E2, Rancho Mirage, Ca. 92270 ph. (760) 834-8860 fax (760) 834-8861 YOUNG ENGINEERING SERVICES www.valuengr.com To: City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 Attn: Angelica Submittal: Letter of Transmittal Today's Date: 8/19/13 City Due Date: 8/7/13 Project Address: 78-252 Hacienda La Quinta Plan Check #: 13-926 C 1st ❑ 2nd ❑ 3rd ❑ 4th ❑ 5th ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) I_; Your Pickup Includes: Descriptions: Includes: # Of Copies: ® 1 Structural Plans ❑ ® 1 Structural Calculations ❑ ❑ Truss Calcs ❑ ❑ Soils Report ❑ ❑ Structural P/C Comments ❑ ❑ Redlined Structural Plans ❑ ❑ Redlined Structural Calcs ❑ ❑ Redlined Truss Calcs ❑ ❑ Redlined Soils Reports ❑ Comments: Structural content is approvable. Descriptions: Revised Struct. Plans Revised Struct. Calcs Revised Truss Calcs Revised Soils Report Approved Structural Plans Approved Structural Calcs Approved Truss Calcs Approved Soils Report Other: Structural Plan Review Time = 1.5 HR CITY L LA QUINT) This Material Sent for: COMMUNIIYDEVELOPNI ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: John W. Thompson Rancho Mirage Office : ® (760) 834-8860 Other: ❑ CERTIFICATE OF COMPLIANCE" Desert Sands Unified School District o 47950 Dune Palms Road ¢ BERMUDA DUNESr CA) RANCHO MIRAGE rj Date 8/28/13 La Quinta, CA 92253 t -A INDIAN WELLS 'r . No. 31790 (760) 771-8515 � P QUINTS �V PINDIO yr�1 Owner O'Keefe APN # 646-280-003 Address 78252 Hacienda Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F.. Lot # No. Street S.F. Unit 1 78252 Hacienda 125.- Unit 6 RECEIVED Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 AUG 2 8 2013 Unit 5 Unit 10 CITY OF LA QUINTA Comments COMMUNITY DEVELOPMENT At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 125 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Bob Edwards Check No. Bank Name/Recipient of Certificate Telephone Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exempted byr n CGilvrey Payment Recd ,Over/Wider, Signature - f NOTICE:'Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in,Whkh you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant. Copy -'Applicant/Receipt Copy - Accounting AT/ Evaluation Service A Division of Architectural Testing — Certification Services . Code Compliance Research Report CCRR-0131 Subject to Renewal: 07/13/2014 Issued: 07/13/2012 Visit www.ati-es.com for current status t Revised: 08/22/2012 Page 1 of 12 Solatube International, Inc 2210 Oak Ridge Way Vista, CA 92081 (760)-597-4400 www.solatube.com infoO.solatube.com 1. Subject Solatube Tubular Daylighting Devices 2. Research Scope 2.1 Building Codes: 2009 International Building Code (IBC) 2009 International Residential Code (IRC) 2010 Florida Building Code (FBC) including High Velocity Hurricane Zones for 160 DS, 290 DS and 750 DS models 2.2 Properties Structural Performance Durability (UV, Weathering) Burning 3. Description 3.1 Solatube Tubular Daylighting `Device (TDD) Models recognized by this report are; The Solatube Brighten Up@ Series Models 160 DS (10 inch Tube. Dia.), 290 DS (14 inch Tube Dia.) daylighting systems. The Solatube SolaMaster@ Series Models 330 DS -O, 330 DS -C, 750.DS-O and 750 DS -C are daylighting systems available in a 21 inch tube diameter. The "0" and "C" designation infers to. Open (0) and Closed (C) ceiling configurations. These TDD models consist of three primary assemblies; the roof dome assembly, reflective tube assembly and diffuser assembly. These assemblies are detailed in Figures 1, 2, and 3. 3. 1.1 Roof Dome Assembly. Primary components of the dome assembly are the dome, dome ring or tube ring and flashing. 3.1.1.1 A single dome manufactured from impact resistant acrylic polymer is utilized on Models 160 DS, 290 DS, 330 DS and 750 DS. 3.1.1.2 Models 160 DS, 290 DS and 750 DS utilize an additional inner dome manufactured from impact resistant . acrylic polymer or polycarbonate (750 DS) when installation is within the' High Velocity Hurricane Zone as defined by the FBC. 3.1.1.3A dome, ring (160 DS & 290 DS) manufactured from impact resistant Acrylic polymer or tube ring (330 DS & 750DS) manufactured from PVC, connects the inner reflective tube, inner reflector, inner dome and outer dome to the flashing. 3.1.1.4 A powder coated steel dome edge protection band is utilized to protect the dome edge on installations on roof assemblies with fire classifications of A, B or C. .3.1.1.5 Powder coated metal flashings are self mounting and are available in pitched and flat configurations. For models 160 DS and 290 DS, the flat configuration is available in both 4 and 6 inch lengths. For models 330 DS and 750 DS, flat configurations in 4, 8 and 11 inch lengths and metal roof flashing are available. Also a support flashing with integral curb cap is available for the 290 DS, 330 DS and 750 DS models. 3.1.2 Reflective Tubes. Reflective tubes and angle adapters have a high reflectance interior tube finish and are manufactured from .015" thick aluminum for 160 DS and 290 DS, and .018" for 330 DS and 750 DS. Two inch wide polymer/foil tape is utilized at all. joints . between tube sections and at vertical seams of each tube. 3.1.3 Daylight Dimmer Assembly A switch operated, electrically driven Daylight Dimmer Assembly is available for installation above the bottom tube on 160 DS 1290 DS and above the round -to -square for 330 DS 1750 DS. The Dimmer Assembly is used to restrict natural light from entering the room. See Section 7.3 and Figure 5. Architectural Testing, Inc. 130 Derry Court • York, PA 17406 717-764-7700 www.archtest.com t ATI -ES Code Compliance Research Report CCRR-0131 Page 2 of 12 3. 1.4 Light Kit Assembly T . 4.3 Florida Building Code Switch operated, electric light kits are available 4.3.1,Models 160 DS, 290 DS, 330 DS and for installation into the bottom tube for the 160 750 DS have been tested to show compliance DS and 290 DS models only.. The kits contain with AAMA/WDMA/CSA 101/I.S.2/A440-08 either an incandescent or fluorescent light bulb. Standard Specification for Windows, Doors, and See Section 7.3 and Figure 4. Unit Skylights. Testing was performed by a '3.1.5 Diffuser and Decorative Fixture Miami -Dade County approved testing facility and Assembly. were signed and sealed by a Professional Engineer with current registration in the state of The Diffuser assemblies are either single or dual Florida. glazed with acrylic or polycarbonate plastic .4.3.2 Light Transmitting Plastics forming part Diffusers classified as a CC2 plastic material. of the models identified in this report have been Diffusers have a flame spread index not shown to have a self -ignition temperature exceeding 200 and a smoke development index greater than 650°F when tested in accordance not exceeding 450 when tested in accordance with ASTM D 1929-96(2000e01), A smoke with ASTM E 84. The Decorative Fixture lenses . development index less than 450 when tested in are comprised of tempered glass. accordance with ASTM E 84-07, and a A dress (trim) ring is,mounted over the assembly combustibility classification of CC2 when tested edge for aesthetic purposes in accordance with For models 160 DS and 290 DS the standard ASTM D 635-06. diffuser . and decorative fixtures (JustFrost, 4.3.3 High Velocity Hurricane Zones (HVHZ) OptiView and Tier Drop) employ a ceiling ring Models 160 DS, 290 DS and 750 DS have been that is manufactured from injection molded additionally tested to show compliance with the impact resistant acrylic and is used to connect requirements of the 2010 Florida Building Code the reflective tubing and diffusers or decorative for use in locations designated as High Velocity fixtures to the interior room ceiling. Hurricane Zones. Testing has shown; The QuadraFrost and Aurora Glo decorative 4.3.3.1 Sufficient resistance to windborne fixtures employ a fixture mounting ring, in debris, as stated in Section 1626 of the Florida addition to the ceiling ring, that is manufactured Building Code when tested to FBC Test Protocol from steel and is used to connect the decorative TAS 201-94. fixture to the interior room ceiling. The ceiling ring is also used to hold the reflective tubing in 4.3.3.2 Sufficient resistance to wind forces as place. determined by Section 1620 of the Florida Building Code when tested to FBC Test Protocol TAS 202-94. 4. Performance Characteristics 4.3.3.3 Sufficient resistance to cyclic wind 4.1 Models identified in this report have been pressure loading as determined by Sections tested for deflection and structural'. response 1625, Table 1625.4 and Table 1626 of the under uniform loading in both the positive Florida Building Code when tested to FBC Test (inward) and negative (outward) directions in Protocol TAS 203-94 accordance with ICC -ES AC16. The maximum _ 4.3.3.4 Sufficient weathering resistance of allowable positive and negative design loads for plastics with outdoor exposure when tested to each model size combination, and associated ASTM G 155 for a period of 4500 hours and anchoring, are indicated in Table 1. subsequent testing to ASTM D 638. 4.2 Models identified in this report have met the air infiltration and :water penetration - acceptance criteria identified in ICC -ES AC16 ' when tested in accordance with Sections 5.3.2 and 5.3.3 of AAMA/WDMA/CSA 101/I.S.2/A440- 05. Architectural Testing, Inc. _ 130 Deny Court • ;York, PA 17406 717-764-7700 www.archtest.com Architectural Testing, Inc. 130 Derry Court • .York, PA, 17406 www.archtest com 717-764-7700 r A TPES Code✓ Compliance Research Report CCRR-0131 Page 3 of 12 5. Installation 5.9 Installation for compliance with the UBC Installation shall be in accordance with the shall be in accordance with UBC Section 2409 this manufacturer's installation instructions and thi and 2603.7 and report. Where differences occur between this 5.10 Installation for compliance with the FBC report and the manufacturer's installation shall be in accordance with FBC Section 2405 instructions, this report shall govern. and 2610. 5.1 The dome attachment for the 10" 160 DS 5.11 For installation on roof assemblies with and 14" 290 DS models ,is accomplished by fire classifications A, B, or C, metal dome edge attaching the dome ring to the flashing and top protective rings shall be installed on the, 160 tube with four (4) #8x1" truss washer head DS, 290 DS, 330 DS and 750 DS models screws and plastic spacers with a snap fit utilizing the 4" flashings. Other flashings noted in between the dome and dome ring. See Figure 1. Section 3.1.1.5 may be needed in order to 5.2 Diffuser assemblies for the 10" 160 DS maintain the required minimum 4" distance from and 14" 290 DS models are comprised of an roof deck to dome edge. acrylic ceiling ring, an acrylic dress ring and dual 6. Supporting Evidence glazed diffuser. The dress ring is snap fitted or 6.1 Manufacturer's drawings and installation twist secured onto the ceiling ring. instructions. 5.3 The Dome attachment for the 21" 330 DS 6.2 Reports of testing and engineering analysis and 750 DS models is accomplished with three in accordance with ICC -ES AC16, Acceptance (3) #8x1-5/8 washer head sheet metal screws Criteria for Plastic Glazed Skylights, approved passing through three (3) equally spaced plastic April 2011. spacers, flashing and into the tube ring. See Figure 2. 6.3 Reports of testing to ASTM D 1929- 5.4 The Dome Assembly for the 21" 330 DS -0 96(2000e01) Test Method for determining and 750 DS -0 (Open Ceiling) models utilize a Ignition Properties of Plastics. butyl putty seal (referred to as a glazing. rope in 6.4 Reports of Testing to, ASTM E84-07, Test installation instructions) between the flashing Method for Surface Burning Characteristics of and tube ring. See Figures 2 and 3. Building Material with equivalency to ASTM E84- 5.5 For the 21" 330 DS -C and 750 DS -C 04. ` (Closed Ceiling) models, the tube ring should be 6.5 Reports of Testing to ASTM D635-06 Test sealed to the outer face of the top reflector tube Method for Rate of Burning and/or Extent and with 2" wide polymer/foil tape. Time of Burning of Self -Supporting Plastics in a 5.6 Diffuser assembly for the 21" 330 DS -0 Horizontal Position with equivalency to ASTM and 750 DS -0 (Open Ceiling) models is D635-03. comprised of an acrylic dress ring and a single 6.6 Reports of Testing to ASTM G 155 glazed diffuser. The assembly is snapped into Practice for Operating Xenon Arc Light the four (4) equally spaced slots provided in the Apparatus for Exposure of Nonmetallic Materials end of the extension tube. and ASTM D638 Test Method for Tensile 5.7 For the 21" 330 DS -C and 750 DS -C Properties of Plastics. (Closed Ceiling) models consist of a square 6:7 A Quality control manual. in accordance diffuser assembly that connects to the round with ICC -ES AC10, Acceptance Criteria for reflective tube through a square to round Quality Documentation, approved June 2011. transition section. 6:8 Reports of engineering and installation 5.8 Installation for compliance with the IBC and analysis for alternate anchorage signed and IRC shall be in accordance with IBC Section sealed by.a Professional Engineer registered in 2405 and 2610 and, IRC Section R308.6. the State of Florida. Architectural Testing, Inc. 130 Derry Court • .York, PA, 17406 www.archtest com 717-764-7700 r �'i►_ ATI -ES Code Compliance Research Report CCRR-0131 r Page 4 of 12 6.9 Testing for Florida Building Code. was 7.3 Daylight dimmer, incandescent light and performed by a Miami -Dade County approved fluorescent light assemblies were only evaluated testing facility (Architectural Testing, Inc. - for effects on performance when TDDs were Fresno, CA) with reports signed and sealed by a tested in accordance with ICC -ES AC16. Professional Engineer registered in the State of Evaluation of these assemblies for compliance Florida. These reports are; to electrical codes is not part of this report. 6.9.1 Reports of testing in accordance with AAMA/WDMA/CSA101 /I. S.2/A440-08 "StandardlSpecification for Windows, Doors, and Unit Skylights"; American Architectural Manufacturers Association, Window and Door Manufacturers Association, and Canadian standards Association. 6.9.2 Reports of testing to Testing Application Standard (TAS) 201-94 "Impact Test Procedures" as required by Section 1626 of the Florida Building Code. 6.9.3 Reports of testing to Testing. Application Standard (TAS) 202-94 "Criteria for Testing Impact & Nonimpact Resistant Building Envelope Components Using Uniform, Static Air Pressure" as required by Section 1620 of the Florida Building Code. 6.9.4 Reports of testing ,to Testing Application Standard (TAS) 203-94 "Criteria for Testing Products subject to Cyclic Wind Pressure Loading" as required by Sections 1625, Table 1625.4 and Table 1626 of the Florida Building Code. 7. Conditions of Use The Solatube Tubular Daylighting devices identified in this report are deemed to comply with the referenced building codes subject to the following conditions: ,7:1Installation shall comply with the manufacturers installation instructions, . this report, IBC Section 2405 and 2610, IRC Section R308.6, UBC Section 2409 and 2603.7, and FBC Sections 2405 and 2610. , 7.2 The wind uplift rating recognized in this report ( See Table 2) is based on attachment to S -P -F wood curbing (Specific Gravity, G=0.42), 5/8" Group 2 Plywood and 22 gauge 33 ksi ' minimum yield steel deck. Installation on a wood substrate with a lesser specific gravity or lesser thickness may result in a lower wind uplift rating. 7.4 Where required by the building official, engineering calculations and details shall be provided. The calculations shall verify that the anchorage complies with the building code for the type of framing and condition of the. supporting construction 7.5 Model 330 DS shall not be installed in High Velocity Hurricane Zones as defined by the Florida Building Code. 7.6 Models 160 DS, 290 DS and 750 DS shall utilize the additional inner dome for use in High Velocity, Hurricane Zones as defined by the Florida Building Code. 7.7 All products are - manufactured in accordance with the manufacturer's approved quality control system with inspections by Keystone Certifications, Inc. (IAS AA -714). 8. Identification Solatube Tubular Daylighting devices produced in accordance with this report shall be identified with permanent labeling that includes the following information: 8.1 The manufacturers name and/or logo, address model number and allowable loads 8.2 The plastic dome glazing thickness and classification (CC2) 8:3 The Name or logo of the independent inspection agency, Keystone Certifications, Inc. (IAS AA -714) 8.4 The , Architectural Testing Code Compliance Research Report mark and report number (CCRR-0131) Architectural Testing, Inc. j 130 Derry Court • York, PA 17406 www.archtest.com 717-764-7700 • r AL --� A TI -ES Code Compliance. Research Report CCRR-0131 Page 5 of 12 9. Code Compliance Research Report Use 9.3 Reference to the Architectural Testing 9.1 Approval of building products and/or internet web site address at www.ati-es.com is materials can only be granted by a building recommended to ascertain the current version official having legal authority in the specific' and status of this report. jurisdiction where approval is sought. j 9.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product or manufacturer by ATI: Table 1 — Maximum Allowable Design Loads and Applicable Codes 3 Positive (+) loads are directed inward; negative (-) are directed outward. 2 Models 330 DS are not approved for use in High Velocity Hurricane Zones as defined by the FBC. 3 All positive design pressures were tested to a safety factor of 2. All negative design pressures were tested to a safety factor of 3. 4 Values indicated are positive and negative design pressure ratings for use with the FBC. 5 Allowable design loads for consideration of water penetration are limited to those values indicated under Wind Loads. . .E Architectural Testing, Inc. 130 Derry Court • York, PA 17406 717-764-7700 w. wwarchtest.com . 7 Dome IBC, IRC FBC Model Series Model No: Dia. (inch)" Thickness Wind Loads ' Snow Load 5 Wind Loads 4 (inch)' (Psi (Pso (per Solatube Brighten -Up® 160 DS . 10 0.125. +70 290 DS 14 0.125 Series -60 +70 330 DS -O? 21 0.168 +150 330 DS -CZ 21 0.168 +70 770 Solatube SolaMaster® , Series -70 750 DS -0 21 0.210 750 DS -C 21 0.210 ATPES Code Compliance Research Report CCRR-0131 Page 6 of 12 Table 2 Anchorage Descriptions for Recognized Wind Uplift Design Pressures Models 330 DS are not approved for use in High Velocity Hurricane Zones as defined by the FBC. Architectural Testing, Inc. 130 Deity Court • York, PA 17406 717-764-7700 www. archtest. com _ ^. Anchor Description and Model #s Anchorage Substrate Quantity Metal Flange to SPF (S. G. .42) Qty 8 wood curb wood curb #10 x 2" Screw Metal Flange to Qty 8 160 DS wood deck 5/8" Type 2 Plywood, #10 x 2" Screw 290 DS Metal Flange to 22 gauge steel Qty 8 Metal Deck - 33ksi Min Yield #10 TEKS Metal Flange to ' s SPF (S.G.>_ .42) Qty 16 wood curb. wood curb ,� #10 x 2" Screw Metal Flange to.- 5/8" Type 2 Plywood Qty 16 330 DS -0 wood deck #10 x 2" Screw 330 DS -C' 750 DS Metal Flange to 22 gauge steel Qty 16 750 DS -0 Metal Deck 33ksi Min Yield #10 TEKS Alum .Flange to Qty 16 Metal Deck 26 gauge steel 4.8mm Zinc -Coated Steel (Non -Corr Roof Deck ugated Roof Type) Rivets Models 330 DS are not approved for use in High Velocity Hurricane Zones as defined by the FBC. Architectural Testing, Inc. 130 Deity Court • York, PA 17406 717-764-7700 www. archtest. com _ ^. Anchor Description and Model #s Anchorage Substrate Quantity Metal Flange to SPF (S. G. .42) Qty 8 wood curb wood curb #10 x 2" Screw Metal Flange to Qty 8 160 DS wood deck 5/8" Type 2 Plywood, #10 x 2" Screw 290 DS Metal Flange to 22 gauge steel Qty 8 Metal Deck - 33ksi Min Yield #10 TEKS Metal Flange to ' s SPF (S.G.>_ .42) Qty 16 wood curb. wood curb ,� #10 x 2" Screw Metal Flange to.- 5/8" Type 2 Plywood Qty 16 330 DS -0 wood deck #10 x 2" Screw 330 DS -C' 750 DS Metal Flange to 22 gauge steel Qty 16 750 DS -0 Metal Deck 33ksi Min Yield #10 TEKS Alum .Flange to Qty 16 Metal Deck 26 gauge steel 4.8mm Zinc -Coated Steel (Non -Corr �'T►_ A TI -ES Code Compliance Research Report CCRR-0131 Page 7of12 NOTE: FLASHING PROVIDED BY SOLATUBE�WEATHERPROOFING DETERMIN D BY SOLATUBE GENERAL CONTRACTOR ANOR PROFESSIONAL R R AS REQUIRED 'r G%'MV6A- wFE a oRR viiucoN�Bfeum NRH STANDARD MHUSERASOMBLY /1 DOME ASSFNIRLY DLRAII A CMHNG MMG ASSEMBLY DETAIL B OWN 160 DS SOLAlUBE 125" DIA 290 DS SOLATUBE I 16.5" DIA TURRET EXTENSION FOR FLASHING TURRET EXTENSION APPLICATION SHOWN WITH PITCHED FLASHING CURB FLASHING UNIVERSAL TILE FLASHING DIM W J DIM 11Y OPENING WOOD ROOF 1YFE W OR V CONSMUC1101111 • USE (8) $10 TEK SCREWS FOR METAL ROOF Figure 1 -160 DS & 290 DS Solatube with Details Architectural Testing, Inc. 130 Derry Court • York, PA 17406. 717-764-7700 www. archtest. com OFTIOMILOCIAPONENTS ITEM NO. Ott. DESCRIPTION 21 1 SHOCK INNER DOME 22 1DAYLIGHT DRAMER 23 1 UNNERSAL UGHT IIT 24 1 TURRET EXTENSION 25 I IDOME EDGE PROTECTION BAND • USE (8) $10 TEK SCREWS FOR METAL ROOF Figure 1 -160 DS & 290 DS Solatube with Details Architectural Testing, Inc. 130 Derry Court • York, PA 17406. 717-764-7700 www. archtest. com A TI -ES Code Compliance Research Report CCRR-0131 WOOD ROOF TYPE IV OR V CONSTRUCTION As�Metr OPEN CEILING D1F MER ASSEM8IY (FOR OPFN CEILING APPUCARONS) ITEM NO. QTY. tX OMPTION 1 $ OUTER DOME 2 1 TUBE RING 3 8 SPACER 4 1 SCREW wax I.T $?As S 1 GLAaNG ROPE B 1 FLASMNG T 1 REFIE=R 8• a SCREWY 10 X 7 SMS 9 1 TOP nmF 10 1 F &M- TUB 11 1 BOTTOM TUBE 12 1 DIFFUSER; 13 1 IRTS TRAMMON ZPY16WL COMPONENTS 10 1 OAYUGHT OIMMER 15 1 TURRETIEXTEMION 16 1 DORtE EDGE PROTECTION BANG 17 1 NATURAE. EFFECTS LENS WON ROUND TO SQUARE TRANSITION DIFFUSER ASSLY&Y (FOR CLOSED CEILING APPLICATIONS) Page 8 of 12 DOME ASSEMBLY DFTAlL'A' CEIUNG ASSEMBLY DEFAIL'C' CUIIB RASPING FASTENERS TURRET EXTENSION FOR RASMNG • USE E 16) Y 10 TE% SCREWS FOR METAL ROOF METAL ROOF RASHING NO -PITCH FLASHING (FOR NON -CORRUGATED ROOF TYPQ Figure 2 - 330 DS Solatube with Details Architectural Testing, Inc. 130 Derry Court a York, PA 17406 717-764-7700 www. archtest. com AL ATI -ES Code Compliance Research Report CCRR-0131 Page 9 of 12 WOODROOF TYPE W OR V CONSTRUCHON ASSEMBLY DOME AiSEl11BLY DETAIL •A' rn ro � r 1 DETAR S' WFUSER F B, SEAL �--DIFFUSER 21' OPEf4 CERUNG OPEN COLING DIFFUSER ASSEMBLY (FOR OPEN CEIUNG AMC BONS) STIR ROOF N 13 ITEMNo. ON. DES(XSPTIDN t 1 OUTER DOME 2 1 TUBE RING 3 8 ISIFACER 4 1 SCREW"X t.T S.W 16- '--i- 6- 1 IFLASIMG 7 1 1 JFMFUECTGR o B (SCREW 010 XT' SMS 8 1 froFFUNE t0 1 EXTENStQv TUBE ti i BOTMNI nos 12 1 DT'FUSER 13 1 RTS 7RAMSrFION OPMNAL 5 14 1 DAYUGMYOMSLER r 15 1 fdsET EXTENSION to 1 DO.\M EDGE PROTECTION BANG 17 1 INNER 00 to / NATURAL EFFECTS LENS - TYPE U OR IR COHKiRUC1T0 WITH ROUND TO SQUARE TRANSITION CEILING ASSEMBLY DIFFUSER ASSEMBLY DETAIL IV (FOR CLOSED COLING APPLICATIONS) 15 FASTENERS CURB FLASHING TURRET EXTENSION FOR FLASHING METAL ROOF FUWIWG • USE (16) k 10 TEK SCREWS FOR METAL ROOF . (FOR HOWCORRUGATED ROOF TYPE) NO -PITCH FLASK= Figure 3 - 750 DS Solatube with Details Architectural Testing, Inc.. 130 Derry Court • York, PA , 17406 717-764-7700 www.archtest,.com �► ' -.-IL A TI -ES j Code Compliance Research Report CCRR-0131 Page 10 of 12 - .BOTTOM 0-3D ANGLE ;! ADAPrMTUSE .90° CONNECTOR - - - GROUND SCREW _ - - - GROUND SCREW- , - r BOTTOM 030 ANGLE' ' - .. FLEXIBLE CONDUIT • THERMAL PROTECTOR +, " k' ADAPTER TUBE _ THERMAL PROTECTOR . s RIGID CONDUIT• - . - i STRAIGHT _ 90• CONNECTOR - - - .( RIGID CONDUfT i - (. ,.� CON14ECTOR - '. LAMP HOLDER- . • t f - •� FLEXIBLE CONDUIT . - LAMP HOLDER i" .` - - - CFL LAMP .STRAIGHT - CFL LAMP . �, CONNECTOR. - 1"„ - - "• 1 1 JUNCTION BOX, _; JUNCTION BOX - - . T._,. ,-� _ , ! BY OTHERS - • -. i 191 ,CEILING JOIST , .191 ; - CfitING JUISI 71/T .71/7 to BOTTOM - - TO BOTTOM r - - OF TUBE OF rUBE- t - - CEILING - .'CEILING .. - - Notes: - B ,ro AtrAPL=a.. 1) Evaluation of these Light Fixtures for - - compliance to applicable electrical codes Is T , . .FLSRACKFT . not part of this report. _ Box 315" Figure 4 - Typical Solatube Light Kit Assembly Architectural Testing, Inc. 130 Derry Court . York, PA 17406 www,archtest.com EVALUATION REPORT Report Number: 0199 Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013 applied on the interior glass surface of the IGU. The space between glass lites is filled with 95% argon gas. Condensation control gasketing for all skylight models directs accumulated water droplets from the inner glass surface to the exterior without compromising required air tightness. 3.2 Deck Mount Units VELUX FS, VS and VSE skylights consist of several integrated components: one panel of flat IGU top - mounted onto an aluminum -dad wood sash (VS and VSE), or directly onto an aluminum -dad wood frame (FS). Top -hinged sash on any VS or VSE skylight is fastened to and supported on a similar aluminum -dad wood frame. Sash and frames are manufactured from white -finished pine wood having a nominal specific gravity of 0.47 and are covered on the weather exposed sides with roll - formed aluminum cladding that is coated with Kynar and lacquer. Frames have mortised comers secured with glue and aligned and stabilized by a 1-3/4 inch long comer nail. A continuous galvanized steel mounting flange with mitered and welded corners is attached to the lower part of the frame and rests upon a foam isolation pad to interface with the mounting surface. .Galvanized nails secure the flange to the frame every 9 inches or less. Only the VS and VSE frames have a support ledge all around the interior face, to which a gasket is stapled for a tight seal with the sash frame. They also support the fixed half of the extruded aluminum sash hinge on the top of the frame head, fastened with 1 inch long # 8 screws spaced at 10 inches. VELUX VS and VSE skylight sashes also use a mortise joint comer construction with one 5/16" inch staple at each corner. The rotating half of the extruded aluminum hinge is fastened with 1 inch long # 8 screws spaced at 10 inches. IGU is secured with hot -applied primary sealant bonded to roll formed aluminum glazing retaining profiles that are secured to the sash or frame using # 8 stainless steel screws of various lengths (1 and 2-1/2 inches for VS and VSE and 1-1/4 inch for FS) spaced every 9 inches. / MAW �� ry All.VS and VSE: skylights are equipped with insect screens. VSE skylights employ a motor -driven sash operator with radio frequency remote control and have exterior sensors to automatically trigger the operator to close an open sash when rain droplets are present. VS skylights utilize a manually -driven rotary operator. Sizes, general dimensions and fastener requirements for deck mount units are described in Tables 1 (FS) and 2 (VSNSE) and Figures 1 (FS), 2 (FS), 3 (VSNSE) and 4 (VSNSE). Energy, light and comfort factors (U, SHGC, VT and CR) are shown in Table 6. 3.3 Curb Mount Units VELUX FCM, VCM and WE skylights consist of several integrated components. One panel of aluminum -framed flat IGU is bottom -mounted onto a rigid polyvinyl chloride (PVC) sash for the VCM and VCE skylights and is directly mounted in the field onto the site -built curb for the'FCM skylight. Hot -applied primary sealant is bonded to the aluminum frame prior to IGU placement, for all three models. Top -hinged sashes on the VCM and VCE Skylights are fastened to and supported on a similar rigid PVC frame with extruded aluminum counter flashing. This frame is supported in the field by the site - built curb. VELUX FCM skylight utilizes a dual-durometer thermoplastic elastomer (TPE) inner frame gasket that is T -nailed to the glazing frame to lock the IGU in place for sealant curing and handling stability. VCM and VCE counter flashing is a mitered and welded frame that is used to fasten the entire unit to the site - built curb. All VELUX VCM and VCE skylights are equipped with insect screens. VCE skylights employ a motor -driven sash operator with radio frequency remote control and have exterior sensors to automatically trigger the operator to close an open sash when rain droplets are present. VCM skylights utilize a manually -driven rotary operator. Sizes, general dimensions and fastener requirements for curb mount units are described in Tables 3 (FCM) and 4 (VCM/E) and Figures 5, (FCM), 6 (VCM/E) and 7 Page 2 of 17 EVALUATION REPORT �Es� Report Number: 0199 Originally Issued: 10/2010 ' Revised: 10/25/2012 Valid Through: 09/2013 (VCM/VCE). Energy, light and comfort . factors (U, SHGC, VT and CR) are. shown in Table 6. 3.4 Tubular Daylighting Devices VELUX SUN TUNNECm TGF, TGR, TMF and TMR Skylights are a series of tubular daylighting devices with an exterior roof flashing capped with a dear acrylic copolymer (Plexiglas® HFI -7) dome unit and an interior ceiling ring with two diffuser layers joined by a reflective rigid or flexible tunnel .(tube). Domes meet CC1 bum rate criteria, smoke density criteria, and ignition criteria prescribed in IBC Section 2604 and the standard referenced in IBC Section 2405.5.: TGF and TGR series consist of a low profile flashing that mounts to the roof deck, projects 4 inches upward and aligns the dome unit to be parallel to the roof deck. TMF and TMR series consist of a pitched flashing that mounts to the roof deck and projects 9 inches upward on the downward roof slope and allows the tunnel opening to be much less inclined than the adjacent roof., - An optional metal turret dome elevator is available for all sizes and flashings if needed to raise the dome elevation by up to 9 inches. An optional galvanized steel fire ring is available to protect the dome. edge where classified roof coverings are required. Sizes, general dimensions and fastener requirements for tubular daylighting devices are described in Table 5 and Figures 8 (TGF), 9 (TGR), 10 (TMF) and 11 (TMR). Energy, light and comfort factors (U, SHGC; VT and CR) are shown in Table 6. species Group 1 or 2 may result in a lower wind uplift rating. 4.2 Installation Installation shall be in accordance with the manufacturer's installation instructions and this report. 5.0 CONDITIONS OF USE VELUX America Deck Mount Glass -Glazed Unit Skylights, Curb Mount Glass -Glazed Unit Skylights and Tubular Daylighting Devices described in this report comply with applicable product performance testing requirements contained in those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Deck and curb mount glass -glazed unit skylights shall not be used in Type I or II construction, over add fume -containing spaces, in wind-borne debris regions or where unusual loading is expected. 5.2 Deck and curb mount glass -glazed unit skylights that are set at an angle of less than 45 degrees from the horizontal shall be mounted at least 4 inches above the plane of the roof except for R-3 occupancies with a minimum roof slope of 3 unit vertical in 12 units horizontal. 5.3 Light transmitting plastic of tubular daylighting devices shall be mounted at least 4 inches above the plane of the roof except for R-3 occupancies with a minimum roof slope of 3 unit vertical in 12 units or for buildings with a nonclassified roof covering. 5.4 Aggregate area, separation and location of tubular daylighting devices shall be in accordance with IBC Sections 2606.7, 2610.5, 2610.6, 2610.7, 2610.8 and 4.0 DESIGN AND INSTALLATION 803.1.1 for those occupancies within the scope of the IBC. 4.1 Design 5.5 Installation of skylights and tubular daylighting Based on the positive and negative performance grade devices. shall be in accordance with IRC Section R308.6 ratings listed in Table 1, identify the product sizes) that for those occupancies within the scope of the IRC. have performance grades in excess of the design pressures that are applicable to the unit's final location. 5.6 Edges of light transmitting plastic of tubular daylighting devices shall be protected by metal or Uplift wind ratings recognized in this report are based on noncombustible edge material except where attachment to a Spruce -Pine -Fir building substrate or nonclassified roof coverings are permitted. other species Group . 2 substrate with full nail engagement. Installation on wood substrate other than . Page. 3 of 17 EVALUATION REPORT (UN!WX `�E Report Number. 0199 . Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013 6.0 EVIDENCE SUBMITTED . lAPMO ES shield and'evaluation.report number (ER - 0199) • Reports of component and assembly testing .and ` evaluation in accordance with ASTM E1300-03,, 7.3 VELUX SUN TUNNELT"" TGF, TGR, TMF, and TMR NFRC 100, 200. and 500 and AAMA/WDMA/CSA skylights covered by this report shall be identified with 101/I.S.2/A440-08. permanent labeling that includes the following information: 7.0 IDENTIFICATION • Risk of, Fall and ID label with the manufacturer's 7.1 VELUX FS, VS, VSE, FCM, VCM and VCE skylights s name; address and full model number and includes covered by this report shall be identified with permanent A traceability code number placed at the bottom labeling that includes the following information: center of the flashing. • Manufacturer's name, address, full model number 7.4 VELUX SUN TUNNELTm TGF, TGR, TMF, and TMR and traceability code number. skylights covered by this report shall, be identified with temporary labeling • that includes the following 7.2 VELUX FS, VS, VSE, FCM, VCM and VCE skylights information: covered by this report shall be identified with temporary pane labeling that includes the following information: Manufacturer's name and address, tested model size and designation, dome. type, NFRC-certified • Manufacturer's name and address, tested model ratings and approved labeling agency. size and designation, glass type and thickness, e' 'Primary and secondary designators as required by NFRC-certified ratings and approved labeling the AAMA/WDMA/CSA 101/I.S.2/A440 specification agency. including but not limited to the positive and negative • Primary and secondary designators as required by performance grade ratings. the AAMANVDMA/CSA 101/I.S.2/A440 specification IAPMO ES shield and evaluation report number (ER - including but not limited to the positive and negative 0199). performance grade ratings. IAPM UE r r O S f ES ®. TM } IAPMO UES #0199 Amir Zamanian, PE Technical Director of Evaluation Service GP Russ Chaney CEO, The IAPMO Group Page 4 of 17 _-._ -r_. .". ...._.._._.._ (2) Based on tested size indicated in Primary Designator Page 5 of 17 Pressure No Water !tration(2) ?0 Pa 5 psf) ?0 Pa 5 psf) Pressure No Water ,tration(2) ?0 Pa 5 psf) ?0 Pa 5 psf) EVALUATION REPORT Report Number: 0199 " Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013 Table 3 — VELUX FCM Skylights;.- Glass Weight = 5 psf Skylight Description Performance Grades Other NAFS Designators (per NAFS) Size Unit size(') Downward Uplift Primary Maximum Air Max. Pressure Code (inches) Download Uplift Primary Leakage (2) with No Water 2222 25-1/2 x 25-1/2 +7 920 Pa Class CW-PG40 0.1 L/s/m 2 Penetration 1430 17-1/2 x 33-1/2 +8,160'Pa (+170 psf) r -8,400 Pa (-175 psf) Class CW- PG170 1301 x 1295* (51x51*)-SKG - <0.1 Us/m2 (<0.01 cfmfft2) 720 Pa (1.5 psf) 1446 17-1/2 x 49-1/2 2222. 25-1/2 x 25-1/2 2230 25-1/2 x 33-1/2 2234 25-1/2 x 37-1/2 2246 25-1/2 x 49-1/2 3030 33-1/2 x 33-1/2 3046 33-1/2 x 49-1/2 3434 37-1/2 x 37-1/2 4646 49-1/2 x 49-1/2 49-1/2 x 49-1/2 Class CW - 2270 25-1/2 x 73-1/2 +5 280 Pa -4,560 Pa PG95 691 x1911* <0.1 'Us/m2 720 Pa (+110 psf) (-95 psf) (27 x 75*)- 2 (<0.01 cfmt t) 05 Psf) SKG Outside Curb dimensions �Z� Based on tested size indicated in Primary Designator Table 4 — VELUX VCM and VCE Skylights — Glass Weight = 5 psf Skylight Description Performance Grades Other NAFS Designators (per NAFS) Size Unit size(') Downward Uplift Primary Maximum Air (2) Max. Pressure with No Water Code (inches) Leakage Penetration (2) 2222 25-1/2 x 25-1/2 +7 920 Pa Class CW-PG40 0.1 L/s/m 2 720 Pa 2234 25-1/2 x 37-1/2 2246 25-1/2 x 49-1/2 3030 33-1/2 x 33-1/2 (+165 psf) . -1,920 Pa 1305 x 1305 2 (0.02 cfmfft) (15 psf) 3046 33-1/2 x 49-1/2 (-40 psf) (51x51*) -SKG 3434 37-1/2 x 37-1/2 4646 49-1/2 x 49-1/2 (') Outside Curb dimensions (Z) Based on tested size indicated in Primary Designator Page 6 of 17 EVALUATION REPORT u Report Number 0199 Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013 Table 5 — VELUX SUN TUNNELTM Skylights . Skylight Description Performance Grades(per 'Other NAFS Designators NAFS) - Size Unit size(' Download Uplift Primary Maximum Air (2) Max. Pressure with No Water Code (inches) _ Leakage Penetration (2) TGF 014 14 +11,970Pa (+250 psf) -2,035 Pa (-42 psf) Class CW-PG40 521 mm (21") -TDD 0.2 Us/m2 0.03 Cfm/ft2) 580 Pa (12 psf) TGF 021, 21 fMF 014 14 +12,000 Pa -3,840 Pa Class CW-PG80 <0.1 Us/M2580 Pa +250 -80 362 mm (14") -TDD <0.01 cfm/ft2 12psf) TGR 010 10 +11,970 Pa (+250 psf) -5,985 Pa (-125 psf) Class CW -PG 125 362 mm (14") -TDD <0.1 Us/m2 (<0.01 cfmfft2) 580 Pa (12 psf) TGR 014 14 TMR 010 10 +11,970 Pa (+250 psf) -4,070 Pa (-85 psf) Class CW-PG85 362 mm (14") -TDD 0.2 Us/m2 0.03 cfm/ft,) 580 Pa (12 psf)` TMR 014 14 r idensation stance (CR) 50 52 50 42 52 55 52 44 50 50 50 42 58 58 58 49 —N/R —N/R EVALUATION REPORT Report Number. 0199 Originally Issued: 10/2010 Revised: 10/25/2012 09/2013 r© (Horizontal Section View)V nm • L N Figure 2 — VELUX FS Skylight (Vertical Section View) r - Page 9 of 17- .:OMPONENT SCHEDULE 11DA COMPONENT A Side Fron-e B Side gIaZina profile C Side frame cove. D Deck Seob E FSS gosket F IGS gasket G H i • UFA.goske, Frorr,e cover with tob Pone J Foam, Deck seol FASTENER S( ITEM FASTENER 0 1Joil L Plue M Screw N Noil Y Staple COMP011ENT SC EDULE ITEPJi CGt1PONENT 0 ITop Frame P jBot!om Frome Q Bolla» glazing profile R Top glczinc; profile S Botiorn frome. cover i Top !dozing profile retoinei U JEoitom corner key V Top left corner I<ey W Seolont EVALUATION REPORT �E6r Report Number. 0199 Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013. Figure 3—VELUX vafvaV- anynynL (Horizontal Section View) COMFONENT,SCHEDULE ITEM PART/COMPONENT A Side frame B Side sash C 05P roil D ,lazing Profile E Covtriug F Side & Bottom Frame -covering Q Frame gcsket I H FTA go°kef iI Focm. Deck seal. J Deck seol K Sealant L Pane M FSS goskel N Sash cornier Trey j Y D ` NN Z Figure 4 — VELUX VSNSE Skylight (Vertical Section View) w FF Page 10 of 17 COMPONENT SCHEDULE ITEM COMPONENT Y Topframe Z Top sash AA Bottom frame BB Bottom sash CC Hinge corner key DO Hinge corner key EE GSP roil FF Operator cover GO BSGA gasket HH TGS gasket II Frame Hinge jj Sash Hinge KK Glazing profile LL Frame cover MM Covering NN TSFA Frame gasket 00 FTSA gasket PP Bottom frame gasket Q0.Foam. Sash hinge RR Operotor FASTENER SCHEDULE (ITEM COMP94ENT SS Nail TT 5crev, UU 5trewy`�_ VV Wood screw Screv: F Code Product dimensionsPone dimensions Throat dimensions 14 488 426 473 - 22 691 629 676 30 894.5. 832 _ 879.5 34 996 _ 933.8 981 46 1301 1238.5. 1286 :. 70 1910.5 1848 Product dimension D P . ' d. i, one imenslon COMPONENT SCHEDULE ITEM PART/COMPONENT A Outer Frame B Pone Spacer C Inner frame gasket D Corner Key ` E Pone F Sealont FASTENER SCHEDULE ITEM PART/COMPONENT G T—nail HWood Screw • I I II I I II I I If I . I II ki `III I... I I II I Throat' dimension'Iit f Figure 5 — VELUX FCM Skylight Horizontal Section View (Typical for Vertical•section View) t " Page 11 of 17.. 1 ; R _ - Size Inside frame - - Throat-,= _ FLM' ' J 22532.5 675.5. .. 504.5 �, 629 EVALUATION REPORT 735.5 _ -\.878.5 'f 708: - _ 832 :• ... 34• ., v 837. .. ,. ....980 .. Report Number. 0199 ._..�. 933.5 , .. +46 .' r�. v ,ti �LL Originally Issued: 10/2010 ' i. � ` j M :•'lam � Revised: 10/25/2012 • M rt "`.,Valid Through: '094013 • `, •.. t' i(�_r�`�i•. 1, l S1WT FEFE/!--_////!////'�Y///////////////O///0��.0///if9 ��/�//!�//////O/�•Y�/L%////////,.f////LY////6///////!%O.O/////O j � �////////,�/.p�O///////0%///!%d///,C/////%//////�//////O//LD//////,YO%//u a� 4. _ - Size Inside frame - - Throat-,= _ FLM' ' --`Pone,:.�,,• 22532.5 675.5. .. 504.5 �, 629 - 30 - 735.5 _ -\.878.5 'f 708: - _ 832 :• ... 34• ., v 837. .. ,. ....980 .. -� ,.809.5 -: .. ._..�. 933.5 , .. +46 1142:, 1286 1114.5 z 1 -1238.5--, y M, s o� rt 1, S1WT FEFE/!--_////!////'�Y///////////////O///0��.0///if9 ��/�//!�//////O/�•Y�/L%////////,.f////LY////6///////!%O.O/////O j � �////////,�/.p�O///////0%///!%d///,C/////%//////�//////O//LD//////,YO%//u %!O//GY///,CO//ld� ®® IIO;IIIPiIi!d;4%Itt:f U!'d14h��yiiUk101';,�. �igl l^'q.Il .11Vppf.NNi'111!tl441d1fl;ll;,i' ®® i i t. EVALUATION REPORTJ'vjl A116 v� ReportNumber...1r' 0199- Originally 199 Originally Issued: 10/2010 t ~ . "- Revised: 10/25/2012 eF Valid Through: 09/2013 •r , 3 ' Size Inside frorne. '. ' - .Throat _. • ,. FLM - t, Pone 22 532.5 "" - 675.5 504.5, - 629 _ 30 735.5 - .. 878.5 _ : - Y «. 708 _ 832' - 34 -837. 980. , '/: •- .: 809.5 - _ �' 933.5- ' 46 .. :.`: 1142 .1286" ' ..•* ". 1114.5 rd r- -1238.5-"'..• AL rrQ i B I W;y D' L BB `..N Nnllyl.lr , 41 t, 4, - e •- [ 11 ..�ullll.Il LA e '�' JI'��i�'((� r � r —• 1 L1 I '1*h * i . r „i l Irl d G ,J• ir -Irl I r .�.ir; .. ... s •. n t r • --------------------------- � r � 'f , , O � � ' tr v � T • • 2 PART SCHEDULE - •t -. f. k ♦,i ITEM PART/COMPONENT ' • r` M�{' j •y- - Z1. x • •.. '4. N Counter flashing ^ `5f • • . �;• �* _ 1`ubimn (Betlom kfl) - - r' K{ 0 tmdoi'an (Rattan r' Q r • • r'. T r�. + >I :.r .. P Screen retainers (Bottom . t .. a t ,f � - i. YJ' J Y s only) , + — -- — t --------- ----- — ` . - fi F�` -•'f v * E O Hinge socket - +� t — Z �� R Plug21 r . C " • ,•? a � ,. ; .' .� - ' p r .S OpeWlx T.. Alain attachment Y : NC .. f. ,~.•-la_ { J - a) L 7 c* e ,V . 32 Threaded Insert X ochme Screw .. • , !. �• .,!" ' r Z; Y* ass Inserl - .. ,. T' •i �t AA ew - , H •, ' i^• 1 * Note desgnoles, this It,. I, Not Shorn , • 1 . O 3 s•s - Items % (4acha,e Saew) k Item Y I . (B,rcss Insert) ore used a Item 5 (Operdar).it. `•+}j I -J, •I1 I I II� _ F * Y � t 'LL •u. '� .� ,.., i.• � i �d r :xG�t � �iliiii i iii �'" � - � t'� + 'A * �i�llii Iii i i +. .. . [.- •',r - Figure 7 'VELUX VCMNCE SkVlighY•. - ',:. .. Vertical Section. View` Page' 13 of 17, Naso ' EVALUATION REPORT uN Report Number. 0199 Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013, COMPONENT/PART'NO. 304390x, 4:1.5 . PART SCHEDULE ITEM PART/COMPONENT A Dome B Pivot—Notched C Insect guard D Intermediate ring E Alignment o—ring F Low -profile flashing G Collor ring - H Flexible tubing I Snap ring ,f DCR Kit Frosted K Crackle finish diffuse L Frosted diffuser M Diffuser gasket N Swingout - 0 Foam gasket P Ceiling ring Q Trim ring FASTENER SCHEDULE ITEM PART/COMPONENT R Semi—Tubulor Rivet S Tape T Screw U Screw V Screw W Screw X Wood screw A x •Z t J ` EVALUATION REPORT w u Report Number: 0199 " Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013 W Y PART SCHEDULE ITEM PART/COMPONENT A Dome B Pivot -Notched C Insecl.guard D Intermediate ring E Alignment o -ring F low-profle floshing C Top elbow H Extension tube I Bottom elbow J Rigid tube gasket CR Kit Frosted K SE OCR Kit -Dual Diffuser L Crackle finish diffuser M Frosted diffuser 0 Diffuser gasket P Swingout 0 Foom gasket R Ceiling ring S Trim ring L FASTENER SCHEDULE ITEM PART/COMPONENT T Semi -Tubular Rivet I .1* U Tope I* V Tape l1 w Screw -----------------� X Screw f ITEMOK M * Y screw .. Z screw DCR Kit Frosted AA Wood screw - D. COMPONENT/PART NO. 300390xx 1` K *Designates a PART/COMPONENT riot shown on this cross-section. - — — — — — — — — — S Figure 9 — VELUX SUN TUNNEL (TGR) Skylight Page 15 of 17 r , EVALUATION REPORT y. Report Number: 0199 It Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013 ------------ M N----------- 0 P Q Figure 10 - VELUX SUN TUNNEL (TMF) Skylight PART SCHEDULE ITEM PART/COMPONENT A Dome B Pivot—Notched C Insect guard D Intermediate ring E Alignment o—ring F Pitched flashing G Collar ring H Flexible tubing I Snap ring J DCR Kit Frosted K Crockle finish diffuser L Frosted diffuser M Diffuser gasket N Swingout O Foam gasket P Ceiling ring O Trim ring FASTENER SCHEDULE ITEM PART/COMPONENT R Semi—Tubular Rivet . S Tape T Screw U Screw V Screw W Screw X Wood screw *Designates o PART/COMPONENT not shown on this cross—section. MAW EVALUATION REPORT �� .ujrs F. Report Number. 0199 r Originally Issued: 10/2010 Revised: 10/25/2012 Valid Through: 09/2013 \i �•�, -ITEM K' SE DCR Kit—Dual Diffuser OOMPONENT/PART Na. 3045W0 . ' (Applies .poly 10 0030 a 1030 =fonts) cls K, I P----- --- Q Figure 11 VELUX SUN TUNNEL (TMR) Skylight .PART SCHEDULE ITEM PART/COMPONENT A Dome ;B Pivot—Notched C Insect guard D Intermediate ring E Alignment o—ring F Pitched flashing G Top elbow H, Extension tube I Bottom elbow J Rigid tube gasket K DCR Kit Frosted SE DCR Kit -Dual Diffuser L Crackle finish diffuser M Frosted diffuser N Clear diffuser 0 Diffuser gasket P Swingout 0 Foam gasket R Ceiling ring S Trim ring FASTENER SCHEDULE ITEM PART/COMPONENT T Semi—Tubular Rivet U Tape v Tape w . Screw X Screw Y Screw Z Screw AA Wood screw FDDD�R.E82681 - Door, Drapery, Gate, Louver, and Window Operators and Systems Page 1 of 2 1/ le 1 t�NLINE CERTIFICATIONS DIRECTORY fDDR.E82681 Door, Drapery, Gate, Louver, and Window Operators and Systems Page Bottom Door, Drapery, Gate, Louver, and Window Operators and Systems See General information for Door, Drapery, Gate. Louver, and Window Operators and Systems ti VELUX-AMERICA INC F E82681 450 OLD BRICKYARD RD GREENWOOD, SC 29649 USA ' w Trademark and/or Tradename: "VELUX" For residential/commercial use: Field installed accessories: Battery back up, Model WLB 100. Remote control skylight operators, Models QVE, VCE; VSE; WCM 140 may be followed by additional suffix numbers and/or letters. Residential/ Commercial Light block blind, Model DS, followed by F or Lor D or H or C, followed by 3 numbers, may be followed by 3 or 4 numbers, may be followed by E. Residential/ Commercial roller blind, Model RS, followed by- F or L or D or H or C, followed by 3 numbers, may be followed by 3 or 4 numbers, may be followed by E. Electric roller blinds and shutters, Models DMA(x), DMF(x), FMA(x), FMF(x), RMA(x), DM##(x), RM###(x) and FM## (x), MM(x), SM(x), where "(x)" may be any alpha -numeric character or set of characters, ##" may be any letters A -Z except A and F, "###"may be any letters A -Z except A. Electric venetian blinds, Models PMA(x), PME(x), PMF(x), PMP(x), PMV(x), PM# -(x), where "(x)" may be any alpha -numeric character or set of characters and "#" may be any letters A -Z except A, E, F, P and V. t Electric window motor assemblies, Models KEM 140, WMG 500, and WMG 520. R Remote control, Model WLI 160(52xx). r IR Transmitters, Models WLR 160 (50xx), WUR 101 (50xx), where "x" may be any alpha numeric character. Remote control senor interface, Model WLF 111 (50xx), where "x" may be any alpha numeric character. For residential/ commercial use: Remote control window, operators, Models KES 160, WLC 160 (52xx), WUC 101 (52xx), WUC 110 (52xx). Residential/commercial skylight window system, Model VSE, followed by'any letter A -Z, followed by several digits used for internal VELUX purpose. Residential/ commercial skylight window system, Model VCE, followed by several digits used for internal VELUX purpose. Last Updated on 2010-04-28 Questions? Print this page Notice of Disclaimer .. Page Too Copyright © 2010 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=FDDR.E... 5/27/2010 FDDR.E82681 - Door, Drapery, Gate, Louver, and Window Operators and Systems Page 2 of 2 Designs and/or Listings (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2., The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2010 Underwriters Laboratories Inc.®" An indepenaent orgafiizallon workl'rng Io -r a s a I a r world roii_p inIegrtty, precision and kno:vleage. r 5 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=FDDR.E... 5/27/2010 .F EVALUATION REPORT • uNE6 'Report Number: 0199 " Originally Issued: 10/2010 SUPPLEMENT, 'Revised: 10/25/2012 Valid Through: 09/2013 DIVISION: 08—DOORS AND WINDOWS. Section: 08 62 00—Unit Skylights REPORT HOLDER: ,. VELUX America, Inc. P.O. Box 5001 Greenwood, South Carolina 29648-5001 (864) .941-4828 ,» www.veluxusa.com EVALUATION SUBJECT VELUX FS, VS, VSE, FCM, VCE, and VCM Deck and Curb Mount Glass -Glazed Unit Skylights VELUX SUN TUNNELTm Skylights (TGF, TGR, TMF, TMR) (tubular daylighting devices) 1.0 Compliance with the following codes • 2010 California Building Code 2.0 Additional Requirements 2.1 Compliance for Materials Used Reports of material testing and evaluation in accordance with Clauses 6 and 7 of AAMANVDMA/CSA 101/I.S.2/A440- 08 cover the applicable requirements of Chapter 7A and 1505.1 for fire resistance 'and Chapter 26 for light transmitting plastic component. Acrylic Domes are in compliance with CBC 2606 and 2610. 2.2 Glazing Requirements - For those applications subject to the requirements of the Division of the State Architect -Structural Safety/Community Colleges (DSA-SS/CC) or the Office of Statewide Planning and Development (OSHPD 1 & 4), refer to Table 1 below for information to verify compliance with the additional provisions of Section 2403.2.1 and Table 2403.2.1 of the 2010 California Building Code. Table 1 –Glass Area, Nominal Frame Lap and Glass Edge Clearance Skylight Model Nominal Design Values -mm (in.) Largest Size Glass Area (ft) Frame Lap Glass Edge Clearance Sides Bottom Top77 Sides Bottom Top FS 13.29 23 (7/8) 23 (7/8) 22 (7/8) 3 (1/8) 4 (1/8) 6 (1/4) VS / VSE 12.02- ` ' 12(1./2) 14(1/2) 14(1/2) 4.5(3/16) 3(1/8) 3(1/8) FCM . 16.51 18'(3/4) 118 (3/4) 18(3/4) 31 (1-1/4) 31(1-1/4) 31(1-1/4) VCE / VCM '16.51, 18 (3/4) 18(3/4) 18(3/4) 31 (1-1/4) 31 (1-1/4) EVALUATION REPORKUNrl E6 , f Report Number. 0199 Originally Issued: 10/2010 Revised: 10/25/2012 . Valid Through: 09/2013 DIVISION: 08—DOORS AND WINDOWS VS and VSE skylights provide natural ventilation via an Section: 08 62 00—Unit Skylights operable top -hinged sash. FS units are fixed. REPORT HOLDER: The glass is continuously supported on all four sides VELUX America, Inc. P.O. Box 5001 Greenwood, South Carolina 29648-5001 (864) 941-4828 www.veluxusa.com EVALUATION SUBJECTS: Deck Mount Glass -Glazed Unit Skylights, Curti Mount Glass -Glazed Unit Skylights Tubular Daylighting Devices 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes • 2009 International Building Code • 2009 International Residential Code 1.2 Evaluated in accordance with • AAMA/WDMA/CSA 101/I.S.2/A440-08 • NFRC 100-2010 • NFRC 200-2010 • NFRC 500-2010 1.3 Properties Evaluated 2.2 Curb Mount Glass -Glazed Unit Skylights VELUX® FCM, VCM, and VCE No Leak SkylightsTm are unit skylights that provide natural light and views into the interior of building spaces. They are intended for use on building roofs sloped from 00 (0:12 pitch) to 600 from horizontal. Each unit is designed to attach to a site -built curb that is constructed from nominal 2 inch by 4 inch wood members of sufficient strength to transfer the skylight loads to the framing members. Skylights may be attached to other materials of equal performance. VCM and VCE skylights provide natural ventilation via an operable top -hinged sash supported by an integral frame assembly: FCM units are fixed. Glass is continuously supported on all four sides using a roll -formed aluminum frame (assembled with ASA comer keys) to resist uplift wind loads. Curb mount products are particularly well-suited for replacement of existing curb -mounted skylights. 23Tb1 D I•ht' D U01 ar ay rg mg evrces VELUX SUN TUNNELTM TGR, TGF, TMR, and TMF skylights are tubular units that conduct natural, light into smaller building spaces. They are intended for use on Structural Performance building roofs sloped from 140 (3:12 pitch) to 600 from Air and Water Tightness horizontal. Operating Forces Durability 3.0 DESCRIPTION ° Thermal and Optical Performance 3.1 Insulating Glass Units 2.0 USES Insulating glass units (IGU) used in deck and curb mount 2.1 Deck Mount Glass -Glazed Unit Skylights glass -glazed unit skylights are constructed from either a 1/8 inch or 5/32 inch thick Gear Low -E3 -coated tempered ® glass lite outboard, a sheet of 7/32 inch thick laminated "VELUX FS, VS and VSE No Leak SkylightsT"' are unit glass lite inboard and a stainless steel spacer system for skylights that provide natural light and views into the an overall thickness of 5/8 inch. Laminated glass lite interior of building spaces. They are intended for use on inboard is comprised of two sheets of 3/32 inch thick building roofs sloped from 140 (3:12 pitch) to 850 from heat .strengthened glass that are each permanently horizontal. Each unit contains 'an integral supporting bonded, to either a 0.030 or •0.090 inch thick polyvinyl frame with 'continuous mounting flange intended for butyral (PVB) clear interlayer. When increased thermal direct attachment to roofing substrate. performance is desired, an additional Low -E coating is Page,1 of 17 Copyright® 2012 by Intemationel Association of Plumbing and Mechanical Officials. Al rights reserved. Printed in the United States. No part of this publication maybe reproduced, stored in an electronic retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior varitien permission of the ` publisher. Ph: 1-8774IESRPT • Fax: 909.472.4171 • Web: www iaomoes.orq • 5001 Fast Philadelphia Street - Ontario, California 91761-2816- -USA ® E ED Prescriptive Certificate of Compliance: CF -1R ADD Residential Additions (Page 1 of 5 Site Address: 78-252 Hacienda La Quinta Enforcement Agency: 107/01/2013 Date: Proposed see Note Standard Values From JA4 Table General Information Project Name O'Keefe Residence Climate Zone # 115 # of Stories 1 Building Type Single Family [3 Multi Family. Circle the Front Orientation&, S, W or Degrees Conditioned Floor Area of Addition (CFA): 123 SQ.FT. New Addition Size: 0 Less than or equal to 100 El Less than or equal to 1000 fe o not use this orm or additions greater than 1000 NOTE: For Alterations to an existing home, submit a completed CF -JR -ALT Form. Exception: Existing HVAC systems that are replaced or altered to serve the addition may be included on the CF -]R -ADD Form. PRESCRIPTIVE ENVELOPE REQUIREMENTS FOR ADDITIONS For standard wood and assemblies meeting the Cavity R -value only.' • For 100, ftz additions; the Proposed values must be equal or greater than the Standard column or when indicated when using Package D, "Pkg D ". Enter values in the shaded Proposed Columns. • For less than 1, 000ft2 additions must comply with 'Pkg D" requirements unless indicated in the Standard Column. To meet "Pkg D" minimum energy compliance re uirements, see RCM.Appendix B, Table 151-C or 152 in the RCM. Enter values in the shaded Proposed Columns. Size of Addition 100 fe or less Less than 1,000 ftp Component Standard Proposed Comment Standard Proposed Comment Ceiling Insulation R-19 Minimum Pkg D R-38 Table 151-C Wall Insulation R-13 Minimum R-13 R-13 Minimum Floor Insulation R-13 Minimum Pkg D Table 151-C Fenestration U- U- factorSHGC factor SHGC 0.40 Pk D Enter Values g From "FenestrationAddition 50 fe ft2 Proposed — Areas" Page 2 of 5 U- factor U- SHGC factor SHGC Enter Values From "Fenestration Proposed Areas" Page 2 of 5 0.40 Pk D g .40 .35 Maximum Glazing Area Alone 23 1 Enter Values From "Addition Allowed Fenestration Areas" Page 3 of S For West -Facing ftz Orientation2�' 6.2 Radiant Barrier N/A Pkg D Table 151-C Roofing N/A See Roofing Products Below. Pkg D See Roofing Products Below OPAQUE SURFACE DETAILS For the furred portioned of Mass Walls see Furring Stri s Construction Table below. A B C D E F G I H I J Proposed see Note Standard Values From JA4 Table Tag/ Assembly Name ID� or Tvoe2 Framing Thickness, Material Spacing, and Size or Other' U- factor" Framed Continuous JA4 JA4 Table Cavity Insulation Assembly Numbers R-value6 R -Value? Cell Values Proposed Assembly U -facto? Wall 2x4 16" o.c. 151-C R-13 R-13 Roof 2x12 16" o.c. 151-C R-38 R-38 Note: For furred assemblies, accounting for Continuous Insulation Tvalue, see Page JA14,31a d Yqu ti H a ll. Fpz'cglcn{ t' I e 1 use the Mass and FurringConstruction table below. 1 ll , �"► %4 J cx JHFETY DEPT, APPROVED FOR Registration Number: Registration Date/Time: 2008 Residential Compliance Forms March 2016b 1 Prescriptive Certificate of Compliance: CF -1R ADD Residential Additions (Page 2 of 5 Site Address: Enforcement Agency: Date: 78-252 Hacienda La Quinta Proposed Properties of Masonry and Concrete 107/01/2012 Tota _4-:J 1. Fenestration area is the area of total glazed product (i. e. glass plus j pm. area maybe the glass area plus a "2 inch frame" around the glass. I 2. Enter value from Component Package D Requirements in Table 151-C. 3. Actual fenestration products installed and as indicated in CF-6R-ENgForm SHGC value than that specified on the Fenestration Proposed Area to 4. Submit a completed WS -3R Form if a reduced SHGC is calculated with 5. If applicable at this stage enter `NFRC"for NFRC Certified window Walls From Reference 1. For Tag/ID indicate the identification name that matches the building plans. 2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc ... Indicate in column G the Frame material and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies. 3. Enter the thickness for mass in inches or Spacing between framing members enter; 16 "or 24 "OC,• or Other for all other assembly description such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel, and etc.... 4. Based on the Climate Zone; enter the equivalent U factor found in JA4 Table based on the R -Value from Table 151-C 5. Enter the Table number that closely resembles the proposed assembly. 6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0 ". 7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter "0 ". 8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J. 9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply. FURRING STRIPS CONSTRUCTION TABLE FOR MASS WALLS ONLY A I B I C I D I E F I G I H I I I J I K L M Proposed Properties of Masonry and Concrete Added Interior or Exterior Insulation Tota _4-:J 1. Fenestration area is the area of total glazed product (i. e. glass plus j pm. area maybe the glass area plus a "2 inch frame" around the glass. I 2. Enter value from Component Package D Requirements in Table 151-C. 3. Actual fenestration products installed and as indicated in CF-6R-ENgForm SHGC value than that specified on the Fenestration Proposed Area to 4. Submit a completed WS -3R Form if a reduced SHGC is calculated with 5. If applicable at this stage enter `NFRC"for NFRC Certified window Walls From Reference in Furring Space from Reference Joint Appendix Table 43.5 4.3.6 4.3.7 Joint Appendix Table 4.3.13 3 N U U w ° c Q 5 Ueo Assembly A ] c •� F" o d 21: d ° Final Assembl Mass Name or JA4 Table % y c , Z Thickness Type Number' ¢ > Q > U -factor's Comment N/A 1. Indicate the Mass Thickness from Reference Joint Appendix JA. 2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc ... Indicate the Frame type and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies. 3. Enter the Table number that closely resembles the proposed assembly. 4. Enter the row and column of the U factor value. 5. Enter the Effective R -value listed in the JA4 Table Number. 6. The Final Assembly is calculated by using Equation 4-1 or Equation 4-4 of the Reference Joint Appendix JA4. Enter the value in Column L. 7. Insert the Final Assembly U- actor value back on to the Opaque Su ace Details table in Column J. FENESTRATION PROPOSED AREAS Orientation Fenestration Type and Frame (North, East, ProposedAreal Maximum Maximum NFRC or indow, Glass Door or Skylight) South, West) ((W) 3 SHGCZ• 1,4 Default Values' 46"x46" Skvliqht 14.7 .40 .35 Tota _4-:J 1. Fenestration area is the area of total glazed product (i. e. glass plus j pm. area maybe the glass area plus a "2 inch frame" around the glass. I 2. Enter value from Component Package D Requirements in Table 151-C. 3. Actual fenestration products installed and as indicated in CF-6R-ENgForm SHGC value than that specified on the Fenestration Proposed Area to 4. Submit a completed WS -3R Form if a reduced SHGC is calculated with 5. If applicable at this stage enter `NFRC"for NFRC Certified window ME '1i e ! 5; o ! 1 BUILDING & SAFETY DEPT. shfla b�ju Rr,(fZ$ r au jDower U f le abouts`." NSTRU TION exterio sa r�i or CEC "Default.' values ou d 'n Table 116-A ass, the fenestration ctor and/or a lower r B. Registration Number: 2008 Residential Compliance Forms DATE RegistrationDate/Time: - HERSProvider: March 2010 Prescriptive Certificate of Compliance: CF -1R ADD Residential Additions (Page 3 of 5 Site Address: Enforcement Agency: Date: 78-252 Hacienda La Quinta 107/01/2013 ADDITION ALLOWED FENESTRATION AREAS Check applicable box below if the roof addition is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the boxes are A B C D E Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the above Cool Roof criteria F Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, check CFA of Addition Allowed % Allowed Area Area Removed2 Maximum Allowed Area Proposed Areas Thermal of CFA (A x B) ft C + D Reflectance 3,4 (Table Above) Total Fenestration Area3 123 0.20 12.3 66.7 79 > 14.7 West Fenestration Area 14.7 0.05 6.2 66.7 72.9 >_ 14.7 e uired In CZ's 2, 4 & 7 -15 04 0 0 1. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1:12. 2. Glass removed to make way for the addition. 3. For additions less than 1, 000 ft2 the standards allows glazing removed during the remodel to be added to the glazing area allowance. The maximum allowed glazing area for the addition is the CFA x 20% + glass removed to make way for the addition. 4. In climate zones 2, 4, 7-15, no more than S% of the CFA is allowed for west facing glazing plus west facing glass area removed to make way for the addition. The maximum allowed west facing glazing area is the CFA x S% + west facing glass removed to make wayfor the addition. S. To meet compliance, the Pro osed Area must be less than or equal to the Total Allowed Area or BOTH the Total and West Fenestration Areas. ROOFING PRODUCTS (COOL ROOFS) §151(1)12 Check applicable box below if the roof addition is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the boxes are checked below, the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in §I18(i) are not applicable. Do not fill table below. Lj Roofing compliance Not Required in Climate Zones 1-12, 14, and 16 with a Low -Sloped. Less or 2:12 pitch. Roofing compliance Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped. Roofs pitch greater than 2:12 and product weight less than 5lb/ft Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the above Cool Roof criteria Roof constructions that have thermal mass over the roof membrane with at least 25 lb/ft is exempt from the above Cool Roof criteria. Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, check e applicable box below if Exempt from the Roofing Products "Cool Roof' Requirement: Roof Slope Product Weight Product Aged Solar Thermal CRRC Product ID Numbers < 2:12 > 2:12 < Slb/ft> 5lb/ft ' Type2 Reflectance 3,4 Emittance SRI 0676-0021 Q ❑ [H] 1:1 Bulltwp Roofing ©4 0.63 0.87 75 0 0 0 04 0 0 0 0 1 04 0 0 0 04 0 0 1 0 r4 0 0 0 0 104 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www. cooIra oYs. org/products/search. nhp. 2. Indicate the type of product is being used for the roof top, i.e. single ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same directory and use the equation (0.2+0.7(pi,,;,;oi — 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance. 4. Check box if the Aged Reflectance is a calculated value using the equation above. 5. Calculate the SRI value by using the SRI- Worksheet at http://www.eneay.ca.gov/title24/and enter the resulting value in the SRI Column above and attach acopy of the SRI- Worksheet to the CF -1R. o apply Liquid Field Applied Coatings, the coating must be applied a rowtth� �ntVie r�s ac �n e ; * l ckness or coverage recommended by the coatings manufacturer and meet minimum performance �rfc( e e s d ' e a licable coating: 0 Aluminum -Pigmented Asphalt Roof CoatingTO Cement -Based R of CoatingsPj�WFe: { A FOR UUNl ) 1 nWt-1 t 1%J1-4 Registration Number: Registration Date/Time: , HERS Provider: 2008 Residential Compliance Forms March 2010 Prescriptive Certificate of Compliance: CF -1R ADD Residential Additions (Page 4 of 5 Site Address: 78-252 Hacienda La QUlnta Enforcement Agency: Date: 07/01/2013 HVAC SYSTEMS - HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydropic space heating. Individual dwelling DHW heaters must be storage gas or propane f red, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage DHW heater less than 50 gallons with an energy factor greater than 0.90 maybe used. Hot water pipe insulation from the DHW heater to the Duct or Configuration Minimum Distribution Duct or Piping Efficiency Type and Insulation Thermostat SEER/EER or COP Location R -Value Type Minimum Distribution Piping (Central, Split, Heating Equipment Efficiency Type and Insulation Thermostat Space, Package or Type and Capacity' 2,1 AFUE or HSPF Location° R -Value Type H dronic Existinq 1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc.) 2. Electric resistance heating is allowed only in Component Package C, or except where electric heating is supplemental (i.e., if total capacity < 2 KW or 7,000 Btuthr electric heating is controlled by a time -limiting device not exceeding 30 minutes). See §151(b)3 exception. 3. Refer to the HERS Verification section on Pages 3 and 4 of the CF -IR -ADD Form for additional requirements and check applicable boxes. 4. Indicate Type or Location(Ducts, H dronic in Floor, Radiators, etc. HVAC SYSTEMS - COOLING List water heaters and boilers for both domestic hot water (DHW) heaters and hydropic space heating. Individual dwelling DHW heaters must be storage gas or propane f red, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage DHW heater less than 50 gallons with an energy factor greater than 0.90 maybe used. Hot water pipe insulation from the DHW heater to the Configuration Cooling Equipment Type and Capacity 1,2 Minimum Distribution Duct or Piping Efficiency Type and Insulation Thermostat SEER/EER or COP Location R -Value Type (Central, Split, Space, Package or H drone Existinq [@ NO External Tank Water Heater Type/Fuel Type' Distribution Type Standard, Recirculatin z Number In System 1. Indicate Cooling Type (A/C, Heat pump, Evap. Cooling, etc). 2. Refer to the HERS Verification section on Pages 3 and 4 of the CF -IR -ADD Form for additional requirements and check applicable boxes. 3. Indicate Type or Location(Ducts, H dronic in Floor, Radiators, etc. WATER HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydropic space heating. Individual dwelling DHW heaters must be storage gas or propane f red, non -recirculating, and may not exceed 50 gallons. If no natural gas is connected to the building, an electric storage DHW heater less than 50 gallons with an energy factor greater than 0.90 maybe used. Hot water pipe insulation from the DHW heater to the kitchens and on all underground hot water i es is required in all corn onent acka es in all climate zones. Heated Slab Insulation f `u i 9 Y YES JEINO I Slab edge insulation required for heated slabs in all Climate:tjnes(3See dTetafitts a 4Y8-W=st& dards. Raised Slab Insulation A D D /W= [:]YES [@ NO External Tank Water Heater Type/Fuel Type' Distribution Type Standard, Recirculatin z Number In System Tank Capacity (gal) Energy Factor or Thermal Efficiency Insulation R-Value3 Existing 1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc) 2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do not allow the installation of a recirculating water heating system for single dwelling units. 3. The water heating tank and i es shall be insulated to meet the requirements o 150 ' . SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below. These items may require written justification and documentation and special verification. Applicable special features shall be marked with a YES and be specified within the plans. Radiant Barrier (Roof) [@YES I x NO Required in Climate Zones 2, 4, and 8-15 for additions larger than 100 ft Slab Edge (Perimeter) Insulation YES I rxJ NO I In Climate Zone 16 under Component Package D, R-7 insulation is Heated Slab Insulation f `u i 9 Y YES JEINO I Slab edge insulation required for heated slabs in all Climate:tjnes(3See dTetafitts a 4Y8-W=st& dards. Raised Slab Insulation A D D /W= [:]YES [@ NO In Climate Zones 1, 2, 11, 13, 14 & 16 R-8 insulation i require �i�Cltat�e T 1CT"N� -4 ins ation is required under Component Package D. .1 11� Thermal Mass - To obtain Compliance Credit for the installation of the kl mass, u* e Approac Registration Number: Registration Date/Time: 2008 Residential Compliance Forms HERS Provider: March 2010 Prescriptive Certificate of Compliance: CF -1R ADD Residential Additions (Page 5 of 5 Site Address: Enforcement Agency: Date: 78-252 Hacienda La Quinta 07/01/2013 HERS VERIFICATION SUMMARY - The enforcement agency should pay special attention to the HERS Measures specified in this checklist below. A completed and signed CF -4R Form for all the measures specified shall be submitted to the building inspector before final ins ection. Duct Sealing & esting HERS verification is re uired or this measure. AYES oNO In all Climate Zones, if a new space -conditioning system (HVAC equipment and ducting) is installed to serve the addition Address: Cinnabar Lane If If Applicable EA or EPE alone, the ducts are to be sealed and tested per § 15l(f)10. OYES city"tate/zip: Coachella, CA 92236 In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned Responsible Building Designer's Declaration Statement Rio space to serve the addition, the ducts are to be sealed and tested per §152(b)1D. El EXCEPTION: Existing duct systems • I certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. that are extended which are constructed insulated or sealed with asbestos. building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building enmit application. . In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including replacement of the air handler, outdoor Signat re: �i- . n A Ql t' NT A Lm Company: B U I LTINeNGi DesignsM.� condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) and will serve the addition, the ducts R are to be sealed and tested per §I52(b)1E. ❑YES ]NO EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS verification in accordance with procedures in the Reference Residential Appendix RA3. EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space. - EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos. Refri erant Char e - Split System HERS verification is re uired or this measure. []YES CHINO In Climate Zones 2 and 8-15, if a newly ducted split A/C or heat pump is installed to serve the addition alone, a refrigerant charge measurement shall be verified per § 151 7A. DYES In Climate Zones 2 and 8-15, if the existing HVAC equipment is replaced (including replacement of the air handler, outdoor EVO condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) and will serve the addition, a refrigerant charge measurement shall be verified per 152 1F. Central te Fan Inrated Ventilation System — Airflow and Fan Watt Draw - do not apply for additions 1,000 ftz or less. Ducted Split S stems - Air Conditioners and Heat Pumps: Airflow and Fan Watt Draw HERS verification is required []YESx❑NO In Climate Zones 10 through 15, if a new space -conditioning system (HVAC equipment and ducting) is installed to serve the addition alone, the airflow and fan watt draw shall be verified per § 151 7B. []YES M. O In Climate Zones 10 through 15, if the existing space -conditioning system (HVAC equipment and ducting) is replaced and LJ will serve the addition, the airflow and fan watt draw shall be verified per § 152 1F. Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is a urate and complete. Name: Gabriel Rios Signature: Company: Rios Designs I% Date: 07/01/2013 Address: Cinnabar Lane If If Applicable EA or EPE (Certification #): city"tate/zip: Coachella, CA 92236 Phone. 760-485-7431 Responsible Building Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. • The building design features.identified on this Certificate of Compliance are consistent with the information provided to document this building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building enmit application. . Name: Gabriel Rios Signat re: �i- . n A Ql t' NT A Lm Company: B U I LTINeNGi DesignsM.� �t7-V/Rios 4 - 012' Address: 49-901 Cinnabar LaneI- V FOR C i Ttee: NSTRU ION city/state/zip: Coachella, CA 92236 Phone:_485-74 1 For assistance or questions regarding the Energy Standards, contact the eyVlot the a :0- -3 Registration Number: 2008 Residential Compliance Forms Registration Date/Time: HERS Provider: March 2010 Mandatory Measures Summa MF -1R Residential (Page 1 of 3 Site Address: Enforcement Agency: Date: 78-252 Hacienda La Quints 1 1 07/01/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1R, CF -IR -ADD, or CF-IR-ALTForm) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1R Form with plans. DESCRIPTION Building Envelope Measures: §116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). §117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. § 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. § 118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of § 118(i) when the installation of a Cool Roof is specified on the CF -1R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§ 150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. §150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. § 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. § 150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no eater than 2.0 permlinch. and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 113(c)5. § 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)lA: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or ggreater. § 1506)1B: Unfired storage tanks, such as storage tanks or backup tanks for o � e ei 1 ' t t water tanks have R-12 external insulation or R-16 internal insulation where the internin v is c e e or of he tank. § 1500)2: First 5 feet of hot and cold water pipes closest to water heater n9LrpcLrNM s&ct&kof i circulating sections of hot water pipes are insulated per Standards Table 150-B. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and )iping inj tg e e g Nol4e,4 and indir ct hot water tank shall be insulated to Table 150-B and Equation 150-A. i ION § 1500)2: Pipe insulation for steam hydronic heating systems or hot waters terns >15 psi,4neetp the requir ents of Standar s Table 123-A. § I500)3A: Insulation is protected from damage, including that due to sunli t mois a and wind. § I500)3A: Insulation for chilled water piping and refrigerant suction lines ' cludes a va or retar tyre onditioned space. 2008 Residential Compliance Forms August 2009 Mandatory Measures Summa MF -1R Residential (Page 2 of 3 Site Address: Enforcement Agency: Date: 78-252 Hacienda La Quinta 1 07/01/2013 § 1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Ducts and Fans Measures: §150(m)l: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings eater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. § 150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150(m)7: Exhaust fan systems have back draft or automatic dampers. § I50(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. § 150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §I50(m)l0: Flexible ducts cannot have porous inner cores. § 150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: § 114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §1 14(b)l: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating § 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §I50(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of § 150(p). Residential Lighting Measures: §150(k)l: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by § 150 2. §150(k)3: The wattage of permanently installed luminaires shall be determined as specified by § 130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by § 130(d), and shall not contain a medium screw -base socket. § 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of § I50(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed,lighting�itchens. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftdor NOO,watt.Vford�wolpg i Sn g� t ilnl2 6A0 maybe exempt from the 50% high efficacy requirement when: all low efficacy,lumrn'aires in the- itch c n � gym' a man al on occupant sensor, dimmer, energy management system (EMCS), or a multi -s elle VLcfgra3gttijq c9t�{l tc�m a I pe anently installed luminaries in garages, laundry rooms, closets greater than 70 sq�a a feet, and p fogTjoir acy and ontrolled by a manual -on occupant sensor. ) �--��J J §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more Qi@gp @'0i"4'JFp$x'4 oot of i luminated cabinet. §150(k)10: Permanently installed luminaires in bathrooms, attached and detac red garag , 1 ms, cl sets and tility ro ms shall be high efficacy. g 2008 Residential Compliance Forms August 2009 Mandatory Measures Summar MF -1R Residential (Page 3 of 3 Site Address: Enforcement Agency: Date: 78-252 Hacienda La Quinta 1 1 07/01/2013 EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of § 119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupant sensor. § 150(k) 11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of § 119, or by a manual -on occupant sensor that complies with the applicable requirements of § 119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with § 150 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to § 150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §I50(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to § 130(d). §I50(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146 § 150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicable requirements of § 119. CITY OF LA QU I NTA WILDING & SAFETY DEPT. APPROVED FOR CONSTRUSLTION 2008 Residential Compliance Forms I DATE APY I August 2009