Loading...
0005-126 (PAT)r� LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date B 5 , C Dates C; Signature of Contractor' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. .4 1 have and will maintain workers' compensation insurance, as required by Sdbfibn 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier vN TED PAC1171C IAS Policy No. NWAt 10194$ -00 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' com ensation rovisions of Section` 3700 of the Labor Code, I sh°all forthwith comply with those' provi5 ons:• Date: 2;#1l0 Applicant Tri Sit' i� f Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. tBUILDING PERMIT PERMIT# DATE i VALUATION LOT TRACT L -4X-4190 JOB SITE APN ADDRESS 80-574 IXK AC-,*% - y OWNER CONTRACTOR / DESIGNER / ENGINEER N ' SW,r� 4A ZWnT ITAOE ByVI 4 WALJM. I✓r01 71 C 1 IND AN AVE 7161 ]NDW4A A%1t RIVOISME CA 92504 RIVMMw CA 92504 (909)'84-0841 CBL44 5357 USE OF PERMIT PATI© COVERY4D PATIO &k1REPLACE. 243 SQ. Fr. PORCHIPATIO 20,00 SF RE"f.MATED COST OF CO.NSMUMON 1,231.90 PKRbUT FEF scrW.ARY PLAN CHRICK FEE 101.000.439.318 S40M - CONSTRUCTION FEE 101-00"18-000 �Pi3.00 EI. ECTRIC:AL FlER 101-000,420-000 $19.50 PLUMBING nVE, .. 101-000-419-000 $118.00 MT"k3-' 0TAL C OXtJ UCTPTON AND PLAN? C,%D,,CK $141.45 LESS PRr�-P.A:LD fW.9 T0100 I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned pro�pe/rfty for %in�sp�ct�ion purposes. urposes RECEIPT �DATE goojSignature (Owner/AentDate 12 BY /"O. FV i I DATE FINALED I INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans 0. K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Dr}rtell - Int. Lath i Final Final 6 BLOCKWALL APPROVALS i POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plug. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final 1 Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: B'" City of La Quinta Building ex Safety Division P.O. Box 1504 Permit # 78-495 Calle Tampico 5 l La Quinta, CA 92253 ,� Tracking Sheet Building Permit Application and Project ddress: Owner's Name: U) -[ ,We5 tAt t A. P. cumber 69 A.C�Sf (C9 l GL rXJ� Legal Description: <City.ST. Zipu oC --S�' D t Contractor:� Telephone�W-7 0 4- O Q jAddress: �� j;y„dllIq,�, ue- Pmject Description:AnW C p'.ST. Zip: PI V.(LZe LQ� Cn (_A J l) Telephone: _ 1 L�- D S 1{-p ,State Li—c. City Lic. #: ArcDEnur.. Desizter: I v00o \4, AddiessI ,z, (QA l c OU�2� /4�7(o -d Cit% l ST Zip: �/L U l K� P� CA 2 a Telephone: _$5,•- �A{�j Construction Type: Occupancy: Statelic _.: CZOS >' t'' ' " " Project type (circle one): New Add'n Alter Repair Demo �Ni—nieof Contact Person:—� � � � Sq. Ft.: # Stories: # Units: 77 Telephone = of Contact Person: Estimated Value of Project: 302 30' C� • :.... >; = ::::> < :;:;':> :.:> APPlfCAillTc>€O0.'': ::. ..:. '-: 1llf TH `::. WEf7.1+tiAIE BEL>Q, .,.:[S.,.;;:.;;>;>;':,;;::;:.;:,:.;;;:.;:.;'.:.;;:;;::< N...><:><':>:::»:>>::>:'.>::>::>:>::>:<:>s::>`::::::<> SubmittalRs :d.::. ''Rec"d TBACiMG.:;.:: .. :..::::;.;;:.;:.;;;;;: ::i: x.::: ;c;.z's?>::::>::::: Plan Sets ...; .:>>: >: .:.. ;. " ;: '. 'Pian>Cie:ksnbmtaed::` °L :. :::AMee at::>»>::<»>:' Structnn! Cabs..; ::}!lse;CheckDeptttdt>::�!'::'»::<>::. .` T s Cake. ;;>....:: ::......' ::::. ; :...:...:: . •>:.:Cilled.£astaeis;P.enaa»....::...:,.:, ti.. ,.. ; :.; cP�aa'C�edc:Bataaeci:>::>`:`:<'.>'•':• . Title 24 Cala: :.::: .:>.: Plants . :.... d� Ca>uf:tuori �►...? Grant Deed :....::...c:>:::; :'PhiosrioabmiaeA;: rani School F ;.: . ': a:::< '; ^><:•<:::;><:; :' :;'i<>::':;« .: S'. 4. Sobeenactnr>ittt>:.;::;:::::;:;;>::::•<;:;;;;:.:;:;:::;:::.:;: ... ..: . <. '�onactsP , Contraetor.iaia :.';r Date C i B asiness:Lie: Y ;< # t orke a.Co® ' ::. ,.; :.......: .. .. ........ ........ Planning .......... Pub. IsA. ... `.t .......:::: H. Fire Mar. A �..... Elf BDePto A rov A p ai:;>::a :;>:.; :.:...... >: ::::»::.::. Ag- P :. ...... ':Dite:o[$aa! aiiafPe} > y EXHIBIT "A" LOT 52 TRACT 28603-1 PATIO. ADDITION SCALE 1"=20' SHEET 1 OF 1 SHEETS PROPOSED PATIO & OUTDOOR FIREPLACE ADDITION 6g• i' FF=473.2 P=472.7 GF=472.7 'w MIT ASE I/Ds coNsuc rlNO YORSE • OOIOCN SCHULTZ 79-799 Old IMr.r w •(760) 771-4013 Lo Qinta. CA 9220 FAX 771-4073 MDSE—,.. PLANNING • ENGINEERING • SURVEYING 8.0' 8.0' 51 TITLE 24 REPORT Title 24 Report for: THE RYDER COLLECTION PLAN #1 HERMITAGE, LOT 52 LA QUINTA, CA Project Designer: STEVEN WALKER HOMES Report Prepared By: GINA BROWN RIVERSIDE ENGINEERING 3600 Lime Street Bldg. 1, #117 Riverside, CA 92501 (909) 369-1700 Job Number: 5622 Date: 3/21/00 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.0 By EnergySoft Job Number: 5622 User Number: 1160 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 5 Form C -21R Computer Method Summary 6 HVAC System Heating and Cooling Loads Summary 9 EnergyPro 2.0 By EnergySoft Job Number:' 5622 User Number: 1160 1 Certificate of ComDliance: Residential (Part 1 of 2) CF -1 R THE RYDER COLLECTION 3/21/00 Project Title Date PLAN #1 HERMITAGE, LOT 52 LA QUINTA Project Address Building Permit # RIVERSIDE ENGINEERING (909) 369-1700 Plan Check! Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,101 fit Total Conditioned Slab Area: 2,101 ft2 Building Type: (check one or more) ® Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front orientation: All Four Orientations Number of Dwelling Units: 1.00 Number of Stories: 1 Floor Construction Type: ® Slab Floor ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-15 Wall (/.15.2x4.16) Wood 0.026 Exterior Wall R-19 Roof (R.19.2x8.16) Wood 0.051 Exterior Roof FENESTRATION Shad inp.Devices Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind etc. shadescreen etc. Yes / No Yes / No Front 55.3 0.52 0.55 Drapery Bug Screen ❑ X❑ ❑ X❑ Left 113.0 0.52 0.55 Drapery Bug Screen X❑ ❑ ❑ X❑ Rear 226.9 0.52 0.55 Drapery Bug Screen X❑ ❑ ❑ x❑ Rear 21.9 0.52 0.55 Drapery Bug Screen❑ X❑ ❑ X❑ Right 50.0 0.52 0.55 Drapery Bug Screen❑ X❑ ❑ X❑ ❑❑ ❑❑ El 1:1 Q 1:1 El R El El ❑❑ EJ El ❑❑ Run Initiation Time: 03/21/00 16:12:11 Run Code: 963680331 EnergyPro 2.0 By EnerqySofl User Number: 1160 Job Number: 5622 Pa e:3 of 9 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R THE RYDER COLLECTION 3/21/00 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Contras Furnn -e 60% AFUE Ducts in Attic 42 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Thermostat Location / Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 49 Sethark HVAr System WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value RHEEM 44V50 Small Gas Standard ]_ 4nrn00 50 0.61 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Name: Title/Firm: STEVEN WALKER HOMES Address: Telephone: Lic. #- a (ate (sn Enforcement Agency Name: Title/Firm: _ Address: Telephone_ Documentation Author Name: GINA BROWN Title/Firm: RIVERSIDE ENGINEERING Address: 3600 Lime Street Bldn. 1 #117 Riverside, CA 92501 TelephoN: (909)369-1700 (s—ignature) (date) IEneravPro 2.0 By EnergySoft User Number: 1160 Job Number: 5622 Page:4 of 9 1 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures *§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑X § 150(b): Loose fill insulation manufacturers labeled R -value. a*§ 150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value. F*§ 150(d): Minimum R-13 raised Floor insulation in wood framed floors. El§ 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 perm/inch. §118: Insulation specified or installed meets quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 2. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. FRI§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed for fireplaces, decorative gas appliances and gas logs. Space Conditioning, Water Heating and Plumbing System Measures X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. F IA -71 §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(1): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3.lnsulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R-4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. [X—] '§150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with current UMC Sections 601 & 603; insulated to a minimum R-4.2' or enclosed entirely within conditioned space. Connections of metal ducts and inner core of flex ducts mechanically fastened. Openings sealed with mastic, tape, aerosol sealant or other duct closure system that meets the applicable UL 181. Openings greater than 1/4 inch sealed with a combination of mastic and either mesh or tape. Insulated flexible duct is marked with R - value every 3 feet. 2.Factory-fabricated duct and closure system (including collars, connections and splices) comply with UL 181; pressure - sensitive tapes, heat -activated tapes, and mastics comply with UL 181. 3. Field -fabricated Duct Systems. a. Factory -made rigid fiberglass and flexible ducts comply with UL 181, pressure -sensitive tapes, mastics, aerosol sealants or other closure systems meet the applicable requirements of UL 181, UL 181A or UL 181 B. b. Mastic sealants, mesh, and pressure -sensitive tapes comply with applicable UL 181. Mesh and mastic non-toxic,water resistant and rated for exterior use. c. Drawbands used with flexible ducts shall be either stainless-steel worm -drive hose clamps or UV -resistant nylon duct ties, have a minimum tensile strength rating of 150 pounds, tightened with adjustable tensioning tool. d. Aerosol -sealants meet applicable UL 181 requirments, applied per manufacturer specifications, and any tapes or mastics used in combination meet UL 181. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems have either automatic or readily accessible, manually operated dampers. §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on -oft switch, weatherproof instructions, no pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. FX] §115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot light. Lighting Measures a§150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with tubs or showers (alternative: in laundry, garage, etc. with all outdoor lighting mounted to the building 40 lumens/Watt or equipped with motion sensor): and recessed incandescent ceiling fixtures are IC (insulation cover) approved. EnergyPro 2.0 By EnergySoft User Number: 1160 Job Number: 5622 Page:5 of 9 Computer Method Summary (Part 1 of 3) C -2R THE RYDER COLLECTION 3/21/00 Project Title Date PLAN #1 HERMITAGE, LOT 52 LA QUINTA Project Address Building Permit # RIVERSIDE ENGINEERING (909) 369-1700 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance method (Package or Computer) Cimate one Source Energy Standard Use (kBtu/sf-yr) Design Facing North Margin Facing East Margin wall- 467 0 026 p0_ qn, Facing South Margin ElR-15 Facing West Margin Wall 901 0.026 180 gn 40.16 1.49 39.34 2.31 40.15 1.49 40.26 1.39 Space Heating 41.65 ❑ ElR-19 F-1 RAS Wall 0& 152x4 1 1st Floor Roof (R 19 2x8.16) 1st Floor ❑❑ Space Cooling 101.44 89.10 12.34 88.61 12.83 89.53 11.91 87.49 13.95 Domestic Hot Water 12.64 1 10.891.76 ❑❑ 10.89 1.76 10.89 1.76 F1 10.89 1.76 1140.14 15,,84 16.8 1 14n zi7 15 16 rl�8-63 1710 Totals 15s-73 F-1 F] _ BUILDING F1 COMPLIES This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence. This plan has been analyzed with identical features in all orientations. GENERAL INFORMATION Conditioned Floor Area: 2,101 Floor Construction Type: Slab Floor Building Type: Single Fam Detached ❑ Raised Floor Building Front Orientation: All Four Orientations Number of Dwelling Units: 1.00 Total Conditioned Volume: 21,010 Number of Stories: 1 Slab Floor Area: 2,101 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC) System 9101 91 010 11 00 ConrlitinnPrl ',Pthark -2 n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt YIN Form 3 Reference Location / Comments Wall 395 0.026 _0 go ® R-15 Wall lW 152x4 16) 1 rt Floor wall- 467 0 026 p0_ qn, IX ElR-15 Wall rw 15 2x4 1 R) 1st Flnnr Wall 901 0.026 180 gn ®❑ R-15 Wall pN 15 2x4 1 R) 1 st Floor Wall 530 0.026 270 go Roof 2,101 0.051 _0 _ 0 11 ❑ ElR-19 F-1 RAS Wall 0& 152x4 1 1st Floor Roof (R 19 2x8.16) 1st Floor ❑❑ °❑❑ ❑❑ F1 F-1 F-1 F1 F-1 F] F1 F1 ❑❑ ❑❑ ❑❑ ❑❑ F-1 --1 I F1 F1 0 E Run Initiation Time: 03/21/00 16 n Code: 96368033 EnergyPro 2.0 By Energysoft User Number: 1160 Job Number: 5622 Page:6 of 9 Comauter Method Summary (Part 2 of 3) C -2R THE RYDER COLLECTION 3/21/00 Project Title Date FENESTRATION SURFACES # Type Area U- Value SHGC Act. Azm. Tilt Location / Comments J__ Window Front (North) 55 3 _0_59_0_ 0 55 0 90 1st Floor 2 Window Left (East) 113.0 0.520 0.55 90 90 1st Floor 3 Window Rear (South) 226.9 0.520 0.55 180 90 1st Floor 4 Window Rear (South) 21.9 0.520 0.55 180 90 1st Floor 5 Window Right (West) 50.0 0.520 0.55 270 90 1st Floor INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # 'Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Drapery 0.68 Bug Screen 0.76 2 Drapery 0.68 Bug Screen 0.76 0.0 0.0 0.0 0.0 0.0 0.0 3 Drapery 0.68 Bug Screen 0.76 3.0 3.0 10.0 0.1 10.0 10.0 _ 4 Drapery 0.68 Bug Screen 0.76 _ 5 Drapery 0.68 Bug Screen 0.76 EnergyPro 2.0 By EnergySoft User Number: 1160 Job Number: 5622 Page:7 of 9 1 Computer Method Summary (Part 3 of 3) C -2R THE RYDER COLLECTION 3/21/00 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 2,340 0.76 0 0 0 1 st Floor Slab Perimeter _ 221 0_76 0.0 _ 0 1 st Floor HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80° Ducts in Attic 42 Setback HVAC System Insul. Pipe Hydronic Piping pipe System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.0 SEE B Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Rated' Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value Svstem Name Type Tvpe Svst. (Btu/hr) (aal) Efficiencv Loss (%) Ext. RHEEM 44V50 Small Gas Standard _ 1 40,000 50 0.61 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 03/21/00 16:12:11 Run Code: 953680331 EnergyPro 2.0 By EnergySofl User Number: 1160 Job Number: 5622 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THE RYDER COLLECTION 3/21/00 SYSTEM NAME FLOOR AREA HVAC System 2,101 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Heating System Output per System 89,000 Total Output (Btuh) 178,000 Output (Btuh/sgft) 84.7 Cooling System Output per System 34,000 Total Output (Btuh) 68,000 Total Output (Tons) 5.7 Total Output (Btuh/sqft) 32.4 Total Output (sgftrTon) 370.8 Air System CFM per System 1,210 Airflow (cfm) . 2,420 Airflow (cfm/sqft) 1.15 Airflow (cfm/Ton) 427.1 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 OF Outside Air 0 cfm 67.2 of :OGLING S 11.0/77.40F Outside �..._� 0 cfm 78.8/67.5 of SYCHROMETRICS 67.2 OF 67.2 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM FSensiblel Latent CFM I Sensible 2,828 44,094 5,009 2,190 147,737 0 2,205 7,387 0 0 0 0 0 0 0 0 0 2,205 7,387 48 503 5:0 09 162 510 BDP CO.561AJ036-" 42,145 21,079 178,000 Total Adjusted System Output 42 145 21 079 178,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Au 2 m F Jan 12 am ,earn Temperatures at Time of Heating Peak) 135.8 of I A' Supply Fan Heating Coil 2420 cfm k Return Air Ducts 4 78.8 / 67.5 OF 78.8/67.50F full/ 62.6/61.60F Supply Fan Cooling Coil 2420 cfm 2.0 By EnerpvSoft User Number: 1160 Return Air Ducts Job Number: 5622 Supp y Ir Ducts 132.9 of ROOMS 70.0 of I Supply Air Ducts 63.5 / 61.9 OF 57.5% R.H. ROOMS 78.0/67.2OF I of 9