Loading...
07-2746 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, .CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: N " 07-00002746 80800 HERMITAGE 762-220-004- - - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 20000 Architect or Engineer: BUILDING & SAFETY DEPARTMENT - BUILDING PERMIT --------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C8 C27 C29 License No.: 571747 Date: Contractor: OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I'am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.I. Lender's Name: Lender's Address: LQPERMIT Owner: GALON TERRY 80-80.0 HERMITAGE LA QUINTA, CA 92253 Contractor: DUFF, RAY M 13130 SANTA YSAB DESERT HOT SPRIV (760)329-6904 ` Lic. No.: 571747 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 40 'o� 1 ?1�06 Date: 5/12/08 --------------------------- 7---.---- - - - - - - - -— WORKER'S COMPENSATION DECLARATION,, I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier LINCOLN GENERAL Policy Number CWC00043700 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Application Number . . . . .07-00002746 ------- Structure Information 122SF ADDITION/V-NR/RES-3 [ENGINEERED] -_--- Other struct info 'CODE EDITION 2001/2004/2005 # BEDROOMS 1.00 FLOOD ZONE NO GARAGE SQ FTG .00 PATIO SQ FTG .00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 122.00 .'Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 207.00 Plan Check Fee 134.55 Issue Date . . . . Valuation 20000 Expiration Date 11/05/08 Qty . Unit Charge Per Extension BASE FEE 45.00 18.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 .162.00 Permit . . . . . . ELECT - ADD/ALT/REM Additional desc . Permit -Fee . . . . 19.27 Plan Check Fee 4.82 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/05/08 Qty Unit Charge Per Extension BASE FEE 15.00 122.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 4.27 Permit . . . MECHANICAL Additional desc . . Permit Fee : . . . 19.50 Plan Check Fee '. 4.88 Issue Date Valuation . . . . 0 Expiration Date 11/05/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 ---------------------------------------------------------------------------- EA MECH VENT INST/ DUCT ALT 4.50 Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 18.00 Issue Date . . . . Expiration Date . . 11/05/08 LQPERA11T Plan Check Fee . . Valuation . . . . 4.50 0 LQPERMIT Application Number . . . . . 07-00002746 Permit . . . . . . PLUMBING Qty Unit Charge Per, Extension BASE FEE 15.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ----------------------------------------------------------------------------- Special Notes and Comments 122SF ADDITION/V-NR/RES-3 [ENGINEERED] MASTER BEDROOM SITTING AREA, WITH. EXTERIOR FIREPLACE AT EXISTING PATIO. •2001 CBC, CPC, CMC, 2004 CEC, 2005 ENERGY. May 9, 2008 2:28:48 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 13.46 STRONG MOTION (SMI) - RES 2.00 Fee summary Charged Paid ----------------------------------------------- Credited ---------- Due Permit Fee Total 263.77 .00 .00- 263.77 Plan Check Total 148.75 .00 .00 148.75 Other Fee Total 15.46 .00 .00 15.46 Grand Total 427.98 00 .00 427.98 LQPERMIT Bin # 1 City of La Quinta Building 8r Safety Division P.O Box 1504, 78495 Calle Tampico La Qulnta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:_ gam» , /� Owner'sName: A. P. Number: 7(o Z 2Z0 c30 Address: —56 — 6�> Legal Description: ,4:::,% 1,9,8 9 City, ST, Zip: G,,, <I//Aj4 725: Contractor: /✓ ��/J6"�• Address: Telephone:%� > Project Description: /?,-) ,A! City, ST, Zip: /_4- 4J,1AJ'74 Telephone:. — .!� :•• �; - �',��: ';- State Lic. # : City Lie. #: Arch., Engr., Designer. Address: A) City., ST, Zip: 10A,✓LrS 1 Telephone 2,772— State Lie. #: •;; :• :• .� �;���;:.: `� „�,�:��'}:�: ' ,Y} _ . �. 1. .. , "' ryi%t z Construction Type: Occupancy: Project type circle one New Add'n Altej Repair Demo Name of Contact Person:` f�oLs C�A� i� Sq. Ft : #Stories: # Units: Telephone # of Contact Person: ` Estimated Value of Project: d1le:7 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted D Item Amount 1Structural Cafes. Reviewed, ready for correctionsIDI Plan Check Deposit Truss Cales. Called Contact Person t 41Plan Check Balance Tide 24 Calcs. Plans picked up JJIv L+ C�!��ti 3 Construction Flood plain plan Plans resubmitted �� Mechanical Grading plan 2"° Review, ready for correction issue Jri 1 AjI6 Electrical Subcontactor List Called Contact Person — .J. J Plumbing Grant Deed Plans picked up S.M.1. H.O.A. Approval Plans resubmitted Grading IN HOUSE: 3r' Review, ready for correctionsrusae Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue G�� L School Fees Total Permit Fees y FAIRWAYS ASSOCIATION April 11, 2008 Terry Gallon 80-800 Hermitage La Quinta, CA 92253 Re: Architectural Application- 80=800 Hermitage — CONDITIONAL APPROVAL Dear Mr. Gallon: At the April 7, 2008 meeting of the Architectural Committee the Committee reviewed your plans submitted to add onto your master bedroom along with the addition of a fireplace and T.V. box in your exterior patio. The Architectural Committee has approved your application contingent upon execution of the Maintenance Agreement for the extension of your roof. Further, a spark arrestor must be installed on your fireplace (if it is wood burning). You must comply with all applicable City Codes, setbacks, and City requirements, including licenses and permits, and use of a licensed contractor for this work. Please be advised that I the Maintenance Agreement will be forwarded to the address above approximately .the week following the receipt of this letter. If you should have.any questions in regard to this correspondence please do not hesitate to contact the Association at anytime. Sincerely, PGA WEST Fairways Assoaation - Architecturall Landsca'pe Committee By: Brandi Scott, CCAM PGA WEST Fairways Operations Manager,' For the Architectural Committee Cc:. File Post Office Box 1690 • La Quinta, California 92247 • Phone (760) 776-5100 • Fax (760) 776-5111 Coachella. Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT: CHECK #: TMITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: LTe`rry Galo Date: May 12, 2008 Owner's Name: Terry Galon Phone No. (760) Project Address: 80-800 Hermitage, La Quinta, CA _ _— Project Description: Addition to Master Bedroom APN: 762-220-004 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Total Square Feet of Building Area: 122 sq. ft. Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 05/12/08 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project 65995 Approval 122 sq. ft. $ 0.00 $ 0.00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to AB -181, any mobilehomes being replaced or relocated within the same school district are exempt from developer fees. Any additions of 500 sq. ft. or less is also exempt from developer fees. (Unless additions are on a� M structure_that is under_ construction.) Section 66020 of the Government Code asserted by Assembly Bill 3081, effective'January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance firm tab1csT0 US6.doc 1/16/03 T CNARLES D. GARLAND. ARCMECT Architecture, Interiors, Space and Land Planning, and Structural Design Prindple: Charles D. Garland, Architect Assodate: Efrain Cardenas, Engineer In Training 29 May 2008 The City of La Quinta Department of Building and Safety 78.495 Calle Tampico La Quinta, CA 92253 Project: Addition to the Single Family Residence for: Mr. and Mrs. Galon 80-800 Hermitage PGA West La Quinta, California Regarding: Structural Certification and Clarification To Whom It May Concern, I am a licensed Architect in the State of California and the licensed structural design professional of record for the noted project's structural system. The builder for the noted project has asked I certify some aspects of the existing building discovered during demolition. Shear wall "B", an existing wall, is already a shear wall and currently extends over 14'-0", the full length of the wall, in lieu of the specked 8'-6° length. This difference is such that the specked retrofit holdowns are not required as the uplift drops to under 300 lbs. Also the structure was built in 2002, the construction of which was under the 2001 CBC which required the use of 5/8" diameter anchor bolting. Thus no epoxy set holdowns or anchor bolting is required as presently specified at detail 2/S2. The bolting and anchorage at detail 1/S2 remains cast -in. Therefore the project requires no special inspection as noted at detail2/S2. I hereby state therefore, that the project still conforms to the structural design intent of the structural design calculations and is ready for back checking. If you have please do not hesitate in contacting me. a `W®o_G11991 v � 10/r31/2009 OAO- Charles D. Garland 74854 Velie Way, Suite 5 o Palm Desert, CA 92260 o Phone: (760) 340-3528/Facsimile (760) 340-3728 ' TITLE 24 REPORT fl il , 8,2008' The EnergyPro computer program h authorized by the California Energy Title 24 Report for: TERRY & SANDY GALON 80-800 HERMITAGE LA QUI NTA, CA 92253 Project Designer: CONTRERAS DESIGN ASSOCIATES 41-175 CANTERA LN. BERMUDA DUNES, CA 92203 760-272-9516 Report Prepared By: ADRIANA GIL Adriana Gil 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 (760) 404-7917 Job Number: ADY657-1007 Date: 4/17/2008 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION BY :n used to perform the calculations summarized in this compliance report. This program has approval and is ission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www,energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: ADY657-1007 User Number: 5553 1 I I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 EnergyPro 4.4 by EnergySoft I Job Number: ADY657-1007 User Number. 5553 1 Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R T-E.REZY_&_SAN.D_Y_GAL.ON Building Type: [X] Single Family ❑ Addition 4/_1.7J_2008 Project Title _8.0-8.00_H_ERM.ITAG.E-LA Q_U_I.N_T_A ❑ Multi Family n Existing +.Add/Alt Date Project Address ft2 Building Front Orientation: (E) 90 deg Building Permit # Gil ft2 Fuel Type: (760) 404-7917 Slab on Grade Area: _Ad.r_iana Documentation Author ft2 Fenestration: Telephone Plan Check/Date _EnarmvPio ft Area: 492 ft2 -CA--AClimate Zone 1.5 Field Check/Date Complilgrice Method _R=-19_ -R--0-.0_ Ratio: 19.1% Avg. Climate Zone Number of Stories: TDV Standard Proposed Compliance # of Thermostat Vent (kBtulsf-yr) Design Design Margin Area Space Heating 3.53 3.63 -0.09 -n/a Space Cooling 87.19 86.99 0.20 _n/a Fans 11.85 11.83. 0.03 _R_19 _fZ0-0_ Domestic Hot Water 9.49 9.49 0.00 _0_0.6.5_ Pumps 0.00 0.00 0.00 419_ Totals 112.07 111.93 0.14 .Door None- Percent better than Standard: 0.1% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED _01_A8 Insulation Building Type: [X] Single Family ❑ Addition Total Conditioned Floor Area: 2,572 ft2 ❑ Multi Family n Existing +.Add/Alt Existing Floor Area: 2,450 ft2 Building Front Orientation: (E) 90 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 2,572 ft2 Fenestration: 256_ Average Ceiling Height: 11.0 ft Area: 492 ft2 Avg. U: 0.62 Number of Dwelling Units: 1.00 _R=-19_ -R--0-.0_ Ratio: 19.1% Avg. SHGC: 0.49 Number of Stories: 1 _0.026_ -R_3.8. -FL-0-0- BUILDING ZONE INFORMATION 1.8 # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area -EXISTING-SYSTEM-Zn-1 1,286 1_4,1-4.6 -0-50_ Conditioned- -Setback- 2 -n/a _EXI.SIING_SYSTEM_Zn-2 1,28.6 14.146 0...50_ Conditioned_ -Setback- 2 _n/a OPAQUE SURFACES _01_A8 Insulation Act. 0.9-A7 Type Frame Area U -Fac. Cay. Cont. Azm. Tilt .Roof Wood- .,1.64_ _0_026_ -R=38_ X0_.0_ -0-18 -0.9_A2.4 Wall_ Wood_ 284 0_0.6.5_ _R19_ X0._0_ _9.0__9.0 _0_1--A8 Wall_ Wood_ 256_ _0.0.6.5_ -R_1.9_ X0..0_ _27.0__9.0 _0.9 A7 Wall_ Wood- 31.5_ _0.065_ _R=-19_ -R--0-.0_ -0--90 .28A4 Roof W9.od_ x.22 _0.026_ -R_3.8. -FL-0-0- 0_ 1.8 Wall -Wood- 128_ 0.0.6.6_ -&21_ X0...0_ _2.7.0_ 9.0 Wall_ Wood_ 37- _0_066_ -R2_t X0_0_ -0--90 Roof Wood- 1.,286_ _0.026_ _RR38_ X0..0_ 0_ 18 Wall_ Wood_ 284_ _0..0.6.5- _R_19 _fZ0-0_ -9.0--90 Wall- Wood_ 27.3_ _0_0.6.5_ _R_1.9 X0..0_ _2.7.0__9.0 Wall- Wood- 419_ _0_065_ _R -J.9.0=0..0_ 0_ 9.0 .Door None- 28_ _0.500_ -None_ X0.0_ 0_ 9.0 Gains Condition Y / N Status JA IV Reference Location / Comments Existing- _01_A8 Zone 1_Existing Existing_ 0.9-A7 Zone 1_Existing Existing_ _0.9=A7 Zone 1_Existing Existing_ _0.9- Zone --Existing stew _01_Afl Addittion New -0.9_A2.4 Addittion New _0.9=A24 Addittion Existing_ _0_1--A8 Zone -2 -Existing Existing - -0.9_A7 Zone -2 -Existing Existing_ _0.9 A7 Zone -2 -Existing Existing_ _0.9 A7 Zone -2 -Existing Existing_ .28A4 Zone -2 -Existing Run Initiation Time: 04/17/08 22:14:29 Run Code: 1208495669 EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY657-1007 Paae:3 of 9 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R TERRY & SANDY GALON 4/17/2008 Project Title Date FENESTRATION SURFACES 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING window Overhang Left Fin Right Fin # True Cond. Location/ # Type Len. Hgt. LExt. Area 1.1 -Factor" SHGC2 Azm. Tilt Stat. Glazing Type Comments _1- Window­-Eront_(E)_ _35.0 -0­650-NERC _0_.50 -NERC _90_ _90_ Existing-DEEAULT_DB.LP4NE _Zone 1 -Existing 2 Window Rear -(W)_ 35.0 0.650 NFRC 0_50 NFRC 270 90 Existing DEFAULT DBL PANE Zone 1 Existing 3 Window Rear (W)_ 28.0 0.650 NFRC 0_50 NFRC 270 90 Existing -DEFAULT DBL PANE Zone 1 Existing 4 Window Right M_ 14.0 0.650 NFRC 0_50 NFRC 0 90 Existing_DEFAULT DBL PANE Zone 1 Existing 5 Window Right (N)_ 28.0 0.650 NFRC 0_50 NFRC 0 90 Existin _DEFAULT DBL PANE Zone 1 Existing 6 Window Right (N)_ 14.0 0.650 NFRC 0_50 NFRC 0 90 Existin _DEFAULT DBL PANE -Zone-1 Existing 7 Windg, Right (N)_ 66.0 0.650 NFRC -0-5 0 NFRC 0 90- Exis in _DEFAULT DBL PANE Z0pe1 Existing 8 Window Right (N)_ 28.0 0.650 NFRC 0_50 NFRC 0 90 Existing_DEFAULT DBL PANE Zone 1 Existing 9 Window Rear (W)_ 21.0 0.450 NFRC 045 NFRC 270 9Q New DEFAULT DBL PANE Low E Adddittion 10 _Window Right (N)- 64.0 0.450 NERC 0.45 NFRC 0 90 New DEFAULT DBL PANE Low EAddittion 2.0 11 Window Front (E)_ 17.5 0.650 NFRC 0_50 NFRC 90 90 Existin _DEFAULT DBL PANE Zone 2 Existing 12 Window Front ()_ 17.5 0.650 NFRC 0_50 NFRC 90 90 Existing -DEFAULT DBL PANE Zone 2 Existing 13 Window Rear(.W)_ 2.0 -21.0 0.650 _NF_RC 0 50 _NERC _2.7_0_ 90 Existing_DEEAUL_T_DBL_P_ANE _Zone_2_Existing 14 Window Rear (W)_ 25.0 0.650 NFRC 0_50 NFRC 270 90 Existing -DEFAULT DBL PANE Zone 2 Existing 15 Window Right (N_ 48.0 0.650 NFRC 0_50 NFRC 0 90 Existing -DEFAULT DBL PANE Zone 2 Existing 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 7.0 5.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 7.0 5.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 7.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 7.0 2.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 7.0 4.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 7.0 2.0 2. 0. 2.0 2.0 7 Bug Screen _ _ 0.76 8.0 12.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 7.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 7.0 2.5 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 7.0 2.5 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ TVDe Len4th R -Val. Location JA IV Reference Status Comments Slab Perimeter 103 None No Insulation 26-A1 Existing Zone 1 Existing Slab Perimeter 23 None No Insulation 26-A1 New Addittion Slab Perimeter 103 None No Insulation 26-A1 Existing Zone 2 Existing Run Initiation Time: 04/17/08 22:14:29 Run Code: 1208495669 EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY657-1007 Page:4 of -9 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R TERRY & SANDY GALON Cap. Condition Factor 4/17/2008 Project Title (gal) Status or RE Date Standard Gas 75 Small Gas No Pipe Insulation 1 65,000 HVAC SYSTEMS Heating Location Type Minimum Eff Cooling Type Minimum Condition Eff Status Thermostat Type EXISTING SYSTEM Zn1 Central Furnace 80%AFUE Split Air Conditioner 10.5 SEER Existing Setback EXISTING SYSTEM Zn 2 Central Furnace 80% AFUE Split Air Conditioner 10.5 SEER Existing Setback HVAC DISTRIBUTION Location Duct Duct Condition Ducts Cooling Location R -Value Status Tested? EXISTING SYSTEM Zn1 Ducted Ducted Attic 4.2 EXISTING SYSTEM Zn 2 Ducted Ducted Attic 4.2 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Existing No Existing No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 75 Small Gas No Pipe Insulation 1 65,000 75 Existing 0.62 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water PipingLength (� Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: CONTRERAS DESIGN ASSOCIATES Address: 41-175 CANTERA LN. BERMUDA DUNES, CA 92203 Telephone: 760-272-9516 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) Documentation Author Name: ADRIANA GIL Title/Firm: Adriana Gil Address: 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 Telephone: _(760) 404-7917 (sign6tu e. (date) -Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ❑ ❑ ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑x ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ N ❑ 2. No continuous burning gas pilot lights allowed. ❑ 0 ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑x ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑x ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ Q ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑x ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 0 ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Fx_1 ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY657-1007 Page:6 of 9 -Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions ❑ ❑ ❑ in the cross-sectional area of the ducts. ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ dud tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ dampers. ❑ ❑X ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ Q ❑ 7. Flexible ducts cannot have porous inner cores. ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal, efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ Q ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensors) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY657-1007 Page:7 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE TERRY & SANDY GALON 4/17/2008 SYSTEM NAME FLOOR AREA EXISTING SYSTEM Zn1 1,286 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 49.8 Cooling System Output per System 41,000 Total Output (Btuh) 41,000 Total Output (Tons) 3.4 Total Output (Btuh/sgft) 31.9 Total Output (sgft/Ton) 376.4 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sgft) 1.09 Airflow (cfm/Ton) 409.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF 68.1 OF 68.1 OF Outside Air 0 cfm I QT 68.1 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 2,053 25,630 2,865 531 22,107 0 4,559 2,836 0 0 0 0 0 0 0 0 0 4,559 2,836 34,748 2,865 3 1/2 Ton Unit 26,597 11,127 Total Adjusted System Output 26,597 11,127 (Adjusted for Peak Design Conditions) Supply Fan Heating Coil 1400 cfm TIME OF SYSTEM PEAK I Aug 2 pm res at Time of k Return Air Ducts `i 27.7801 64,000 64,000 Jan 12 am Supply Air Ducts 109.1 OF ROOMS 70.0 OF (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 111.0 / 77.6 OF Outside Air 0 cfm 79.1/66.8 OF 79.1 / 66.8 OF .'e— (0 79.1 / 66.8 OF■ 61.2 / 60.2 OF Supply Fan Cooling Coil 1400 cfm h Return Air Ducts `i Supply Air Ducts 64.3 / 61.3 OF 58.8% R.H. ROOMS 76.0 / 65.8 OF EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY657-1007 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE TERRY & SANDY GALON 4/17/2008 SYSTEM NAME FLOOR AREA EXISTING SYSTEM Zn 2 1,286 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output (Btuh/sgft) 50.5 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 37.3 Total Output (sgft/Ton) 321.5 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfmisgft) 1.24 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above EATING SYSTE 26.0 of Outside Air 0 cfm 68.8 of 11.0 177.6 of Outside � 0 cfm 77.6/64.6 of at ARI conditions 68.8 of Supply Fan 1600 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 930 15,504 2,065 418 15,920 0 2,758 2,043 0 0 0 0 0 0 0 0 0 2,758 2,043 21,020 2,065 20,005 4 TON UNIT 32,202 10,465 65,000 Total Adjusted System Output 32,202 10,465 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am •eam Temperatures at Time of Heatino Peak) 68.8 of E 107.0 of Heating Coil �N Return Air Ducts 4 77.6/64.6OF 77.6/64.7OF M 58.7/57.7OF --(P Supply Fan 1600 cfm Cooling Coil of Coolin h Return Air Ducts `S Supply Air Ducts 105.8 of ROOMS 70.0 of Supply Air Ducts 60.3 158.3 of 52.8% R.H. ROOMS 76.0/64.1OF 1 EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY657-1007 Page:9 of 9 1