Loading...
11777 (SFD)Building Address 51-120 Herrera Owner David Ross Miller Mailing Address P.O. • iBox 722 cLa Quinta, CA 292253 Contractor ' PacifiC Trades des Address Same City Zip Ti -tit aF �Q�w P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 >I. Tela State Lia 8425361 (City 1955 & Classif. Lic. # Arch.,,Engr:, Designer Address Tel.' City Zip 1 State Lic. # LICENSED CONTRACTOR'S DECLARATION I here%affirm that I em licensed under provisions of Chapter 9 ommencing with Section 7000) of Division 3'of the Business and -Professions Code, and my I ense is in full force and effect. SIGNATURE •J �4 DATE OWNER•BUILDER DECLARATION , I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure,l prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for�a�permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Bussness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con. struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C: for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) '-Potty No. Company 0 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you' must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip No. 11777 BUILDING: TYPE CONST. OCC. GRP. A.P. Number 773`064--005 Legal Description 'tit 18 Bloc. 70 Project Description SPI) ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued liy: ` Date Permit Validated by: Validation: i Sq. Ft. `No. No. Dw. Size 1'240 Stori6s 1 Units New Add 8'—;1 :Alter 0 Repair ❑ Demolition O Permit does not include block wall, patio cover, or pool. Estimated Valuation $75.926. Afl . PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. 455.78 Const. 531.50 Mech. 49.00 Electrical i 116.98 Plumbing 141.00 .S.M.I. 7.60 Grading 20.00 Driveway Enc. Infrastructure 1,670.09 Precise P an 25.00 TOTAL 3,017.95 REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued liy: ` Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ UNITS COLL, AREA SLAB GRADE YARD SPKLR SYSTEM 2ND FL. SQ. FT. HEATING (ROUGH) STORAGE TANK FORMS MOBILEHOME SVC. BAR SINK POR. SD. FT. ® DUCT WORK ROCK STORAGE GAR. SO. FT. ® POWER OUTLET ROOF DRAINS HEATING (FINAL) DRAINAGE PIPING CAR P. SQ. FT. GAS (FINAL) TEMP. POLE WALL SQ. FT. DRINKING FOUNTAIN, GROUT URINAL SQ. FT. ® FINAL INSP. ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE: Not to be used as property tax valuation GRADING cu. yd. $ plus x$ FLOOR DRAIN MECHANICAL FEES FINAL INSP. L� WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER ���� (J� GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED VENTILATION LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID Q 11/4 c SEWAGE DISPOSAL SQ.FT.GAR ® 3/ac HOUSE SEWER INSULATIONISOUND FINISH GRADING GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMIFEE PLUMB. FEE STRUCTURE /PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR x SETBACK GROUND PLUMBING NDERGROUND A.C. UNIT COLL, AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS ST ETtTR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APP./EQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ _ $ LUMBER GR. FINAL INSP. L� FRAMING2 G� FINAL INSP.�114?-4 3 c -n ROOFING �� to "[ ` �� 211rlf 3 _ 4'W� 1FINAL V 3 ���� (J� REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING a MESH INSULATIONISOUND FINISH GRADING INSPECTION ZZ 3 CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 1/28/93 1 Type of Permit I La Quinta No. 111980 Permit # Log Owner Name David Miller No. 51120 Street Avenida Herrera city La Quinta Zip 92253 Study Area 113 APN # 773-203-011 Tract # I J Lot # 18 Square Footage 11240 Type of Development I Single Family Residence INo. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/ carports, covered patios/ walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.58 x 1240 or $ 1,959.20 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By David Miller Telephone Name on the check By James E. Lively Assistant Superintendent, Business Services - Fee collected /exempted by Vickie J. Durrett Payment Receded r Signature check No. 15% Collector. Attach a copy of county or city Plan check application form to districi copy for: all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy%`Accountirg,. i -------------------------------------------------------- 03-02-'_S9:, C9: 16 Bib 398 3x07 Dateland Construction Inc. P.01 ®ATELAND CONSTRUCTION CO. 60.306 Highway 1 I 1 a Coachella, CA a 62263 a (61 9) 398.8644 March 2, 1993 To whom It May Concern, On Friday, February 26, 1993 Dateland Construction Company Inc., installed a septic system at 31-120 Herrera for David Miller, DBA Pacific Trades. The system was scheduled to be a 1000 gallon, tank and a 6' X 40''leach pit. A stratum of sande material was encountered at 16' below inlet and continued for 6' and we installed a 24' leach pit, the bottom 6' being in sand, Dateland warrants that the septic system as installed ."will work properly for the life of the structure: Formal wear and tear and abuse excepted, We normally call the Riverside County Department of En iromenFal Health for clearance on changing pit depth. The Health Department is on a compressed schedule closed every other Friday. They wera closed on February 2b and we changed the size of the pit from 40, to 24' on our own initiative. If necessary it is probab?e't'hat Dateland Constructio:z can get a retroactive clearance from the Health Department. the spoils are piled around the excavation. If I can be of any assistance please call me at Dateland Construction Company Inc,, at (619) 398-5544, C-42, L -cense #390698. Sincerely, DATELAND CONSTRUCTION COMPANY +� 1 Robert D. Richert Grading a paving • pipelines - Septic 8ysterns o arease Trapa e Orywolls � _ t 1 COACHELLA VALLEY WATER DISTRICT / CASH RECEIPT DETAIL Received From: ! �" - Address: ❑Copy to: Cash Account No. of ) Service Address — Money AMeter(s) / Order O(Service(s) ❑ Backflow(s) ❑ House Lateral(s) " ❑ Detector Check (s) ❑ Meter Surcharge. . ❑ Sanitation Capacity Charge ❑ W.S.B.F.C. ❑ Temporary Construction Meter ❑ Turn on Charge ❑ Uncollected Account - Name ❑ Inspection Fee - Tract - Fee - ❑ Plan Check Fees Water I Sewer - Tract - ❑ Bond Payment - A.D. - Bond Assmt. ❑ Customer Deposit ❑ Other Remarks: ❑Copy to: Cash _ Check Money Order 41'40 G.A. Code 5 lam• o d TOTAL I— Water Service Cashier_ CVW - 3801189) 1 . 1 r-` PIota COMPUTER`METHOD•SUMMARY Page 1 C -2R ------------------------------------------------------------------------------- Project Title.....`.... PACTRADW Date........ 08/25/92 Project Address.... ... SI- 12j AjZ 1+',1tri_.rZ%__&A --------------------- 1 1 Documentation Author... W J.FINNELL ; Building Permit # ; Company.... ............. ENERGY -,CONSULTING GROUP ; Telephone ..........:... 800-262-9966 Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp; Inc. ; Field Check/ Date CIimat_Zone........ 15..x --------------------- t.MICROPAS3 v3.11'File-PACTRADW Wth-CTZ15• Program -FORM C -2R User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACTRADW ------------------------------------------------------------------------------- ---------------------------- ---------------------------- MICROPAS3 ENERGY USE SUMMARY = Energy Use Standard Proposed .Compliance = _ (kBtu/sf-yr) ---------------------------------- Design Design ---------- Margin = ---------- - = Space Heating.......... 5.76 4.13 1.63 = - Space Cooling.......... 47.99 39.23 8.76 = = Water Heating.......... - 15.08 21.65 -6.57 = - = Total -------- 68.83 -------- 65.01 -------- 3.82 = _ *** Building complies ----------------------------------------------------------------- ----------------------------------------------------------------- with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... 1240 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 270 deg (W) Number of Dwejjing Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade (Package D) Number..of Building Zones.... 1 Conditioned Volume......... 9920 cf Footprint Area ............. 1240 sf Slab -On -Grade Area......... 1240 sf Glazing Percentage......... 9.8 % of FA - Average Ceiling. eight..... 8 ft BUILDING ZONE INFORMATION Floor # of Vent Special Cond- Area Volume Dwell Thermostat Height Vent Area Zone Type -:itioned ,Jsf) ------------------------------ (cf) Units Type --------- ----------------- (ft) ------ (sf) --------- HOUSE Residence Yes 1240 9920 1.00 Setback 2.0 n/a GLAZING SURFACES SC Interior COMPUTER METHOD SUMMARY ;"=.. Area # of Frame Page. 2! ` C;-2R�`. Glass Shade GIs+ Surface ----------- (sf) Panes Type Type value .. R. Project Title.'..*.'..--...'.* PACTRADW --_-.-----Date.: HOUSE' ----- :.... 08/25/92 ------ ----- MICROPAS3 x3.11. File-PACTRADW' ---- ----- Wth-CTZ15' Program -FORM C -2R ; 32.0 User#=MP1325 User -ENERGY CONSULTING 90 0.77 GROUP Run-PACTRADW ; ---=------------ --------------------------- 2 Metal Slider 0.65 ------------------------------------- 90 0.77 drapes 0.66 3 Window 73.0 2 Metal OPAQUE SURFACES 90 0.77 Blinds 0.29 Area.-U- ----------------- Insul Act Solar, .Location/ Form 3 Surfac ------------ (sf) ------ value ----- R-val Azmth --------------- Tilt Gains Comments Reference HOUSE Area Area Shading ----- ---------------- ------------- 1 Wall 100 0.065' R-19 270 90 Yes OUTSIDE None 2 Wall 151- 0.065 R-19 270 90 No GARAGE None 3 Wall 232 0.065 R-19 0 90 Yes OUTSIDE None 4 Wall 247 0.065 R-19 90 90 Yes OUTSIDE None 5 Wall 248 0.065 R-19 180 90 Yes OUTSIDE None 6 Roof 1240 0.029 R-38 0 0 Yes ATTIC None 7 Door 20 0.330 R-2 270 90 Yes OUTSIDE None 8 Door 17 0.330 R-2 270 90 No GARAGE None PERIMETER LOSSES Length ---------------- F2 Insul Surface ------------ (ft)' ------ Factor -------- R-val Location/Comments HOUSE ------- ---------------------- 9 S1abEdge 35 0.900 R-0- TO OUTSIDE 10 S1abEdge 87 0.720 R-0 TO OUTSIDE 11 SlabEdge 21 0.500 R-0 TO GARAGE GLAZING SURFACES SC Interior SC Area # of Frame Open U- Act Glass Shade GIs+ Surface ----------- (sf) Panes Type Type value Azmth Tilt Only Type Shade HOUSE' ----- ------------- ------ ----- ----- ---- ----- ---------- ----- 1 Window 32.0 2 Metal Slider 0.65 270 90 0.77 drapes 0.66 2 Window 16.0 2 Metal Slider 0.65 0 90 0.77 drapes 0.66 3 Window 73.0 2 Metal Slider 0.65 90 90 0.77 Blinds 0.29 EXTERIOR SHADING '---------- ------- Area Area Shading SC of Surface ------------ (sf ) Type'.' --------------------- Ext Shade ----------� HOUSE — 1 Window 32.0 50% bug scrn 0.84 2 Window 16.0 50% bug scrn 0.84 3 Window 73.0 50% bug scrn 0.84 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title .......... PACTRADW�-------------------�`��-4---- Date ........ 08/25/92 ------------------------------------------------------------------------------- MICROPAS3 v3.11 File-PACTRADW.' WtFi-CTZ15 Program -FORM C -2R }� User#-MP1325 User-ENERGY.CONSULTING GROUP Run-PACTRADW ; ---;-----------------------------------------.----.------------------------------ Gas THERMAL MASS Attic R-4 0.816 AirCond 10.00 SEER Attic Area .Thick Heat "Conduct- Surface Mass .TXpe (sf) (in) Cap'- ivity R. -value Location/Comments -------------------------- --------------- HOUSE ------ ----- --------------------- 1 SlabOnGrade 240 3.5 28.0 0..98 R-0 KITCHEN/BATHS 2 S1abOnGrade 1000 3.5 28.0 0.98 R-2 REST OF HOUSE System. Type Storage Electric HVAC SYSTEMS WATER HEATING SYSTEMS --------------------- Capa- R-12 or Pilot # of city Greater Effic- Standby Input Size Heat (gal) Blanket iency Loss Rating (Btuh) Credits 1 38 No 0.994 RE .67% 4.5 kW n/a Recovery SPECIAL FEATURES/REMARKS ------------------------ Minimum Duct Duct Duct System Type ---------------- Efficiency ------------ Location ------------- R -value ------- Efficiency ---------- HOUSE Gas 0.750 SE Attic R-4 0.816 AirCond 10.00 SEER Attic R-4 0.803 WATER HEATING SYSTEMS --------------------- Capa- R-12 or Pilot # of city Greater Effic- Standby Input Size Heat (gal) Blanket iency Loss Rating (Btuh) Credits 1 38 No 0.994 RE .67% 4.5 kW n/a Recovery SPECIAL FEATURES/REMARKS ------------------------ WATER' HEATING 4 Page 1, DHW Project Title......:... PACTRADW Date. ..... 08/25/92 Project Address........ --------------------- Documentation Author..: W J FINNELL'_. ; Building Permit # ; Company ..... :.......... ENERGY CONSULTING GROUP ; Telephone .............. 800-262-9966 Plan Check / Date ; Compliance Method...... MICROPAS3.by Enercomp', Inca ; Field Check/ Date ; Climat'Zone........... 15 -----=-=------------- MICROPAS3 v3.11 File-PACTRADW-.•Wth-CTZ15 Program -WATER HEATING ; User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACTRADW- ------------------------------------------------------------------------------- WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC A. EQUIPMENT DATA ----------------- 1. Water heater type....... 2.'Manufacturer............ 3. Model number............ 4. Ignition device......... 5. Tank volume ............. 6. Recovery efficiency..... 7. Standby loss............ 8. Rated Input ............. 9. Number of Heaters....... 10.Insulation Jacket....... Storage, Electric n/a 38 gal .994 percent x 0.01 .0067 percent/hour x 0.01 15358.5 Btu/hr 1 No B. OPERATING DATA 1. Climate Zone.. ......... 15 2. Water heating budget.... 18700 kBtu/yr/unit 3. Tank set temp............ 140 F 4. Water main temp......... 70 F 5. Daily hot water load..... 50 gal 6. Ambient air,temp........ 72.6 F 7. Adj. Standby Losses..... .0067 8. No. dwelling units...... 1 9. Pump power .............. 0 Watts (0 Watts controller) 10.Pumping energy.......... 0 Watt-hr/yr (0 hr per day) C. WATER HEATING ENERGY CREDITS ------------------------------- 1. Credit Name ............. Recovery. 2. Annual savings........... 2805 kBtu/yr/unit D. ANNUAL WATER HEATING ENERGY ------------------------------ 1. Recovery load........... 10539 kBtu/yr 2. Recovery energy.......... 7781.kBtu/yr 3. Standby loss energy..... 1168 kBtu/yr 4. Pumping energy.......... 0 kBtu/yr source 5. Total energy............ 26848 kBtu/yr/unit source 6. Comparison .............: -8148 kBtu/yr/unit source 7. Points..... ..... =13 8. Water Heating Energy Use 21.65 kBtu/yr/sf (D5 x B8) / 1240 sf GENERAL INFORMATION ------------------- Floor Area ................. 1240 sf Volume ........:............ 9920 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude ............... * 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F SummerRange ............... 30 F Shading Used ............... No Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY HVAC SIZING Heating Page 1 HVAC ------------------------------------------------------------------------------- (Btuh) ----------- (Btuh) ----------- Project Title.......... PACTRADW Date......... 08/25/92 Project Address........ 3225 --------------------- Documentation Author... n/a ; Building Permit # ; W J FINNELL Company ................ ENERGY CONSULTING GROUP Internal Gain .................... Telephone............... 800-262-9966 ; Plan Check / Date ; 1795 1902 Sensible Load .................... Compliance Method...... MICROPAS3 by Enercomp; Inc. ; Field Check/ Date ; CIimat'_Zone ............ 15 --------------------- MICROPAS3 v3.11 File-PACTRADW Wth-CTZ15:° Program -HVAC SIZING ; User#-MP1325 ------------------------------------------------------------------------------- User -ENERGY CONSULTING'GROUP Run-PACTRADW ; GENERAL INFORMATION ------------------- Floor Area ................. 1240 sf Volume ........:............ 9920 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ INDIO Latitude ............... * 33.7 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F SummerRange ............... 30 F Shading Used ............... No Latent Load Fraction....... 0.20 HEATING AND COOLING -------------------------------- LOAD SUMMARY Heating _ Cooling Description -----=--------------------------- (Btuh) ----------- (Btuh) ----------- Opaque Conduction and Solar...... 8872 4244 Glazing Conduction............... 3225 2674 Glazing Solar.:; ................. n/a 6087 Infiltration ..................... 5849 3467 Internal Gain .................... n/a 2550 Ducts ............................ 1795 1902 Sensible Load .................... 19740 20923 Latent Load ...................... n/a 4185 Tota 1 Load ----------- 19740 ----------- 2510Q,-, Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc.`, must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. - CEC Maximum output for gas central furnaces only (area weighted SE): 45000 + (100.0 x (0.750 - 0.71) x 7000)•= 73000 Btuh CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1' CF -1R Project -Title .......... PACTRADW� Date......... 08/25/92 Project Address........ --------------------- Documentation Author... W J FINNELLt ; Building Permit # Company................. ENERGY CONSULTING GROUP. Telephone................ 800-262-9966 Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date ; Clima ''Zone... ...... 15 ------ --------------- ---------------- --------- -------------- --------- ------------------------------------------ MICROPAS3 v3.11 File-PACTRADW- Wth-CTZ15' Program -FORM CF -1R ; User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACTRADW ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area..... 1240 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) Infiltration Control....... Standard BUILDING SHELL INSULATION ------------------------- Component Insul Type R -value Location/Comments Wall R-19 OUTSIDE, GARAGE Roof R-38 ATTIC Door R-2 OUTSIDE, GARAGE S1abEdge R-0 TO OUTSIDE, TO GARAGE GLAZING Glazing Area;,# of Interior Exterior Framing Orientation (sf) Panes Shading Shading Overhang Type ------------------- ------ ----- ---------- -------------- -------- -------- Window Front (W) 32.0 2 drapes 50% bug scrn None Metal Window Left (N) 16.0 2 drapes 50% bug scrn None Metal Window Back (E) 73.0 2 Blinds 50% bug scrn None Metal THERMAL MASS ------------ Area Thickness Hard Surfaced/ Type (sf) �in) Exposed Location/Comments S1abOnGrade 240 3.5 Yes KITCHEN/BATHS SlabOnGrade 1000 3.5 No REST OF HOUSE CERTIF.ICATE.OF COMPLIANCE:, -RESIDENTIAL Page.2 CF -1R Project Title-.......:.PACTRADW Date........ 08/25/92 MICROPAS3.v3.11, File=PACTRADW Wth-CTZ15- Program -FORM CF -1R ; User.#-MP1325 User,. -ENERGY CONSULTING GROUP Run-PACTRADW ; ----------- -------- --------- --------------------- --------------------------- ASSUMED HVAC SYSTEMS Assumed Duct Duct Y.� Assumed System, Efficiency Location R -value ------ - - - - - - - - - - - - - -- Gas -Gas 0.750 -SE Attic R-4 AirCond 10.00 SEER Attic R-4 Actual System --------------- Heating Cooling Cooling Coil ACTUAL HVAC SYSTEMS ------------------- Actual Output Manufacturer'and Model # Efficiency (Btuh) (or approved equal) ---------------------------------------------------- CEC Maximum output for Gas Central Furnaces: 73000 Btuh WATER HEATING SYSTEMS Tank R-12 or # of Vol Greater Manufacturer and Model # Energy System Type Heat (gal) Blanket (or approved equal) Credits -------------------- ---- ----- ------- ---------------------------- ---------- Storage, Electric 1 38 No Recovery SPECIAL FEATURES/REMARKS ------------------------ CERTIFICATE OF COMPLIANCE: {RESIDENTIAL Page_ 3 ,. CF -1R Project Title.......... PACTRADW•,t Dater: 08%25/92 MICROPAS3 v3.11 File-PACTRADW'Wth-CTZ15. Program -FORM CF -1R ; User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACTRADW ; COMPLIANCE STATEMENT This certificate of compliance lists'the building features and performance specifications needed to comply.with Title 24; Chapter 2-53 and Title 20, Chapter 2, Subchapter 4,.Article'l of the California Administrative .code. This certificate has been signed by the individual with overall design responsibility and the building owner,- who' shall retain a copy of it' and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Rerriarks section. DESIGNER Name.... Company. Address. Phone... License. Signed (date) DOCUMENTATION AUTHOR Name.... W J FINNELL Company. ENERGY CONSULTING GROUP Address. 34F INDIAN HILLS MTN CENTER, CA 92561 Phone... 800-262-9966 Signed b y /T (date) OWNER Name.... Company. Address. Phone... Signed (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed (date) 91 MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title...... ... PACTRADW Date........ 08/25/92 Project'Address....... --------------------- Documentation Author... W J FINNELL ; Building Permit # ; Company.; ............ . ENERGY CONSULTING GROUP Telephone...............800-262-9966 ; Plan Check / Date ; Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate;Zone ..... 15 ---------------------- - d.. MICROPAS3 v3.11 File-PACTRADW. Wth-CTZ15 Program -FORM MF -1R ; User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACTRADW ------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards- must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is -incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment * 2-5352(a): Minimum ceiling insulation R-19 weighted average. 2-5352(b): Loose fill insulation manufacturers labeled R -Value. * 2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 2-5311: insulation specified or installed meets CEC quality standards. Indicate type and form. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16. 2-5317: Infiltration/Exfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weath re stripped; all joints and penetrations caulked and sealed. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CEC quality standards. 2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control i. Nn rnntiniin��c b���rninn ��� niln�c �lla.ye.d MANDATORY MEASURES. CHECKLIST:,.RESIDENTIAL. Page 2 MF -1R Project Title.......... PACTRADW"' }= Date:....... 08/25/92 MICROPAS3 v3.11 File-PACTRADW, Wth-CTZ15 Program -FORM MF -1R User#-MP1325 User -ENERGY CONSULTING GROUP' Run-PACTRADW ; ----I---------------------------------------- -------------------------------------- HVAC ------------------------------- - -------------------------------------- HVAC AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations. 2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. * 2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. 2-5316(b): Exhaust systems have damper controls. 2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. _ 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. _ 2-5352(i): Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar water heating systems (first 5 feet*of pipes closest to tank insulated to R-3 or greater). _ 2-5312(Exception 1): Pipe insulation on steam and steam condensate return and recirculating piping. _ 2-5318(d): Swimming Pool Heating 1. System has: r a. On/off switch on,�eater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. LIGHTING AND APPLIANCE MEASURES Design- Enforce- er ment 2-5352(j): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. 2-5314(c): Gas fired appliances equipped.with intermittent ignition devices. 2 -5314(a): -Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC.