06117 (RPL)Building
Address 51-455 Herrera
Owner
Robert Smitmm
C&tyl 4 4 Qu
P.O. BOX 1504
78-105 CALLE ESTADO
LA QUINTA, CALIFORNIA 92253
Address
City Zip 17
Contractor I
Sunair Paol.et
.------- P. 0. Bons; 835
Dosert 1'92260 1 568-4014
State Lic. I City
& Classif. 3972552 Lic. # 529
Arch., Engr.,
Designer
Address Tel.
City lZipStateI
r r Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Profess
io
ns Code, and my license is in full force and
effect. , if At+r'+"' ` ! "°%l 1 ",v, , / f ! If c-
SIGNATURE, 7 ' DATE
If OWN ER -BU ILbQR DECLARATION
1 hereby affirm that I am exempt from the Contractors License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, atter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to Ole a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
aWston 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
O 1, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or 'reproves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. It, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or Improves thereon, and who contracts for
such projects with a contractors) licensed pursuant to the Contractor's License Law.)
O 1 am exempt under Sec. B. 8 P.C. for this reason
Date i Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of;consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed it the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT. It, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives .of this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
6J
No. 06117
BUILDING: TYPE CONST. OCC. GRP.
IA.P. Number 773--084-027
,Legal Description
Project Description Pool
Heater not included
Sq. Ft.
Size
No.
Stories
No. Dw.
Units
New ❑ Add ❑
Alter ❑
Repair ❑ Demolition ❑
Estimated Valuation
9.100
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
76. wi
Const.
117.10
Mech.
30.00
Electrical
27.00
Plumbing
24.00
S.M.I.
.70
Grading
Driveway Enc.
Infrastructure
TOTAL
REMARKS
-,
--
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date 7126/89 Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
IST FL. SQ. FT. ® $
UNITS
COLL. AREA
SLAB GRADE
&ROUGH PLUM `
YARD SPKLR SYSTEM
2ND FL SQ. FT. @
HEATING (ROUGH)
STORAGE TANK
FORMS
MOBILEHOME SVC.
BAR SINK
POR. gp, FT. ®
DUCT WORK
ROCK STORAGE
GAR. SO, FT. ®
POWER OUTLET
ROOF DRAINS
METER LOOP
HEATING (FINAL)
DRAINAGE PIPING
CAR P. I SQ. FT. ®
GAS (FINAL)
WALL Sp. FT.
DRINKING FOUNTAIN.
SQ FT ®
WATER HEATER
URINAL
ESTIMATED CONSTRUCTION VALUATION $
FINAL INSP.
WATER PIPING
NOTE: Not to be used as property tax valuation
WATER SYSTEM
FLOOR DRAIN
MECHANICAL FEES
GRADING
cu. yd.
$ plus x$
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
FINAL INSP.
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
6L)
LAUNDRY TRAY
AIR HANDLING UNIT CFM
REMARKS:
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER. B.T.U.
SQ. FT. ® c
BATH TUB
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 1% c
SEWAGE DISPOSAL
SO.FT.GAR ® V4c
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
&ROUGH PLUM `
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
6L)
(
( c i
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATION/SOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS
GARDEN WALL FINAL
t
wel edlCl o /-Zi o
y
�4 i'✓l t� D r/ � �' � e� e�C CG vr�° i ilJ e � v�
house 5 717-4vG�re
�CTaliit �% I S /7� Ae-20 / f" /. A t C , j g Ies
hVe
use
/4/7
�
+"O'T R I N .1 T Y
L' u. C- N G' I N E E R 1 N G
September 30, 2013
Nancy Egan
615 Calle Fierros
San Clemente CA 92673
Subject: Review of Structural Soundness
51455 Avenida Herrera
La Quinta CA 92253
Dear Mrs. Egan,
At your request we have visited the subject site for the
purpose of reviewing the existing structural conditions
prior to the installation of a new lightweight roofing
system. This review was instigated due to the building
Department requiring that a registered engineer provide
a report regarding the adequacy of the existing roof
supporting a tile roof to be installed in lieu of replacing
the built up with a new foam type built up roofing
Please note that our observation is limited to visible
aspects of the structure. A comprehensive review of the
structure would require destructive onsite testing and
laboratory work to determine the various material
properties and is beyond the scope of this report. Our
opinion outlined herein is based on experience in common
practices in residential construction and structural
engineering.
Our investigation included the visible aspects of the
interior and exterior of the structure. The structure
appears to have been constructed in accordance with the
common best practices and with the exception of the
exposed exterior elements appears to be structurally
sound.
The roof structure consists of conventional framing with
2x rafters with depth and spacing as follows:
Garage: 2x12 at 24" o.c. spanning 19'-6"
Living Area: 2x12 at 16" o.c. spanning 23'-6"
Front Patio: 2x10 at 16" o.c. spanning 19'-9"
The current proposed roof loads are:
For Trinity Engineering 1706 Plum Lane Suite 114, Redlands, California 92374 909-793-4629
Code Roof Live Load: 1 20.0 psf
Based on the calculations attached to this report the additional load due to the tile. will
exceed the recommended loads for the existing structure. At the garage and living areas the
rafters will be overstressed and at the living area the long term deflection will exceed
recommended and tolerable levels with the addition of tile.
It is the recommendation of our firm that tile is not used for the roof of this structure and
that a roofing system weighting 4.5 psf or less be utilized.
Should you have any questions or require additional information please do not hesitate to
contact us at your convenience.
Sincerely,
Carel Stevenson, P.E.
Principal/Owner.
For Trinity Engineering
For Trinity Engineering
0
1706 Plum Lane Suite 114, Redlands, California 92374 l 909-793-4629
°TRINITY
u.E N G
I N E E R 1 N G
Roof Dead Load with Foam: 12.0 psf
Foam Built up
3.5
Sheathing (1/2")
1.5
Rafters (2x12 at 16" o.c.)
2.5
Gypsum Ceiling
2.5
Insulation + Misc
2.0
Roof Dead Load with Tile: 15.0 psf
Light Weight Concrete Tile
6.5
Sheathing (1/2")
1.5
Rafters (2x12 at 16" o.c.)
2.5
Gypsum Ceiling
2.5
Insulation + Misc
2.0
Code Roof Live Load: 1 20.0 psf
Based on the calculations attached to this report the additional load due to the tile. will
exceed the recommended loads for the existing structure. At the garage and living areas the
rafters will be overstressed and at the living area the long term deflection will exceed
recommended and tolerable levels with the addition of tile.
It is the recommendation of our firm that tile is not used for the roof of this structure and
that a roofing system weighting 4.5 psf or less be utilized.
Should you have any questions or require additional information please do not hesitate to
contact us at your convenience.
Sincerely,
Carel Stevenson, P.E.
Principal/Owner.
For Trinity Engineering
For Trinity Engineering
0