Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
08-0918 (RER)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 08-00000918 Property Address: 51556 AVENIDA HERRERA APN: 773-133-003-22 -000000- Application description: REMODEL - RESIDENTIAL Property Zoning: COVE RESIDENTIAL Application valuation: 52304 Tity/ 4 4 Q" Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: 643658 <� Date O II Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/17/08 Owner: ZUNIGA D HUGO AR -TUR 51556 AVENIDA LA QUINTA, CA 53 U JULContractor: JU17 2008 FRONTIER CO STR &n IORS 4076 ALAMO ET F� CFLAQIJI 1-4 RIVERSIDE, CA 925 Op LA (951)342-7913 Lic. No.: 643658 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 046-11817-06 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 37 j of the Labor CgdB, l all fA, � iwith comply /with (/those pr—ow/'sions. Date: Applicant: ,'Y/`/�`'l{f�� WARNING: F (LURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize re resentatives of �th/is/1c my to ter upon the above-mentioned property for in />IcI Zn purposes. Date: " Qgnature (Applicant or Agent):'Y) LQPERMIT Application Number . . . . . 08-00000918 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 428.00 Plan Check Fee 278.20 Issue Date . . . . Valuation . . . . 52304 Expiration Date . . 1/13/09 Qty Unit Charge Per Extension BASE FEE 414.50 3.00 - ---------------------------------------------------------7------------------ 4.5000 THOU BLDG 50,001-100,000 13.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 45.91 Plan Check Fee 11.48 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/13/09 Qty Unit Charge Per Extension BASE FEE 15.00 883.00 - ---------------------------------------------------------------------------- .0350 ELEC NEW RES - 1 OR 2 FAMILY 30.91 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 61.50 Plan Check Fee 15.38 Issue Date . . . . Valuation. 0 Expiration Date . . 1/13/09 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50. Permit . . . PLUMBING Additional desc . . Permit Fee . . . . 60.00 Plan Check Fee 15.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/13/09 Qty Unit Charge Per Extension BASE FEE 15.00 7.00 6.0000 EA PLB FIXTURE 42.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 Application Number . . . . . 08-00000918 ---------------------------------------------------------------------------- Special Notes and Comments DUE TO FIRE DAMAGE DEMO 883 SQ. FT. LIVING SPACE, 135 SQ. FT. COVERED PATIO AND REBUILD PER APPROVED PLANS. ---------------------------------------=------------------------------------ Other Fees . . . . . . . . . ENERGY REVIEW FEE 27.82 STRONG MOTION (SMI) - RES 5.23 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 595.41 --------------------- .00 ---------- .00 595.41 Plan Check Total 320.06 .00 .00 320.06 Other Fee Total 33.05 .00 .00 33.05 Grand Total 948.52 .00 .00 948.52 LQPERMIT TITLE 24 REPORT Title 24 Report for: Fire Restoration For Zuniga 51556 Avenida Herrera La Quinta, CA 92253 Project Designer: Western American Design P.O. Box 2772 Hemet, CA 92546 951-658-2136 Report Prepared By: Marc Farmer Energy and Duct Systems 40492 Clark Drive Hemet, CA 92544 (951) 925-0100 r Job Number: 08-054' CITY OF LA QUINTA Date: BUILDING & SAFETY DEPT. 6/23/2008 APPROVED FOR CON TRTm ON Th E Pro com uter r ram has been used to perform the calculations summarized in i....ba nkirk T has appro and is' e nergy p p og authorized by the California Energy Commission for use with both the Residential and Nonresi enba itding{�t icasStaadacd . This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: 08-054 User Number: 1268 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form INS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 9 EnergyPro 4.4 by EnergySoft Job Number: 08-054 User Number: 1268 J Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R Fire Restoration For Zuniga 6/23/2008 Project Title v Date 51556 Avenida Herrera I a Quinta Project Address Building Permit # Fn and D t $y,t—ms (951) 925-0100 _ray .t Docum tation Author Telephone Plan Check/Date FnerPro Compiffilce Method CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 10.75 3.5.1 7.24 Space Cooling 132.62 133.94 -1.32 Fans 18.06 19.38 -1.32 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 161.43 156.83 4.60 Percent better than Standard: 2.9% Building Type: [X—] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition Q Existing + Add/Alt (W) 270 deg Natural Gas Area: 131 ft 2 Avg. U: 0.79 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Ratio: 14.9% Avg. SHGC: 0.70 Number of Stories: BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume Units Zone Type Type Alt HVAC System as3s7 100 Conditioned Setback OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tift Wall Wood— 134 n 1 m R_13 R-0 n _270 90 Door None 20 0 500 None R-0.0 _270_ An Wall Wood_ 3-46- _0_1.02 —13_1.3- J2-0.0_ —0--90 Wall Wond 127 0 356 None R -n 0 -qf) -qf) Wall Wood 2£38 0 102 R-13 R-00 Igo Roof Wood 88.9 —Q 09$ R_19 R-00 270 0 883 ft2 883 ft2 0 ft2 883 ft2 8.0 ft 1.00 1 Vent Hgt. Area —2 —nla Gains Condition Y / N Status JA IV Reference Location / Comments Altered— 09-A3 (F=09 -Al)— Fxisting + Alter Fxis i g 28-A4 Fxisting + Alter Altered_ _09-A3-(E_=09-A1)—Existingn+after Altered MAI (F=MA1) Existing + Alter Abed Fxisting + Alter Altered 01-A14 (F=t)1-A2)— E)dsting + Alter EneravPro 4.4 by EnerovSoft User Number: 1268 Job Number: 08-054 Page:3 of 9 1 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R Fire Restoration For Zuniga 6/23/2008 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments J__ Window Front C 900 0_790 116-8 _0_Z0 1161-111 270 —91 Altered Do able Metal Clear FYistina + Alter 2 Existing 1.280 116-A 0_80 116-6 Single Metal Clear pre -altered for above 3 Window Front (W) 20.0 0.790 116-A 0_70 116-B 270 90 Altered Double Metal Clear Existing + Atter 4 Existing 1.280 116-A 0_80 116-6 Single Metal Clear pre -altered for above 5 Window Rear (E) 33.3 0.790 116-A 0_70 116-B 90 90 Altered Double Metal Clear Existing + Alter 6 Existing 1.280 116-A0 80 11 6-B Single Metal Clear pre -altered for above Z Window Right Sl 6.0 0- 116-A 0.7 116-6 180�9 Altered Double Metal Clear EAsting + Atter 8 Existing 1.280 116-A 0.80 116-8 Single Metal Clear pre -altered for above 3 Window Right (S) 20.0 0. 11&A 0-ZQ 116 180 90 Altered Double Metal Clear Existing + Alter 1Q Existing 1 , 116-A 0-8 116 Single Metal Clear ire altered for above 11 Window Right (S) 16.0 0.790 116-A 0_70 116-6 180 90 Altered Double Metal Clear Existing + Alter 12 Existing 1.280 116-A 0_80 116-6 Single Metal Clear pre -altered for above 13_ Window Right (S) 16.0 0.790116gAZ0 116-6 180 —20 -Altered Double Metal Clear Existing + Alter 14 Existing 1.280 116-A 0_80 116-6 Single Metal Clear pre -altered for above 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 Existing + Atter 3 Bug Screen 0.76 5 Bug Screen 0.76 6.7 5.0 7.0 1.0 3.0 3.0 7 Bug Screen 0.76 9 Bug Screen 0.76 11 0.76 Bug Screen 13 0.76 Bug Screen THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (so (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Type Insulation Length R -Val. Location JA IV Reference Condition Status Location/ Comments Slab Perimeter 87 None No Insulation 26 -Al Existing Existing + Atter Run Initiation Time: 06(23(08 19:28:21 Run Code: 1214274501 EnergyPro 4.4 by EnergySoft User Number. 1268 Job Number: 08-054 Page:4 of 9 Certificate Of Comm iance : Residential (Part 3 of 3) CF -1 R Fire Restoration For Zuniga 6/23/2008 Project Title Date HVAC SYSTEMS Heating Location Type Minimum Eff Cooling Type Minimum Condition Eff Status Thermostat Type Aft HVAC System Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Altered Setback pre -altered for above Gravity Wall Furnace 65% AFUE Room PTAC with Side 10.0 EER Setback Louvers HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Alt HVAC System Ducted Ducted Attic 6.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Tvpe In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Tdle 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Western American Design Address: P.O. Box 2772 Hemet A 2546 Telephone: 21 Lic. M 6 (signature) rate) Enforcement AJ Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Marc Farmer Title/Firm: Energy and Duct Systems Address: 40492 Clark Drive Hemet CA 92544 Telephone: 951 925-0100 (signature) (date) I EneraWro 4.4 by EneravSoft User Number. 1268 Job Number: 08-054 Pane: S of 9 I Mandatory Measures Summary: Residential (Page 1 of 2) (SIF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance ` requirements from the Certificate of Compliance supercede the items marked with an asterisk (' below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. NIA DESIGNER ENFORCE - MENT Building Envelope Measures § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ Q ❑ M§ 150(.): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). b. outside air intake with damper and control, flue damper and control ❑ ❑ ;§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ EK 1. Masonry and factory -built fireplaces have: § 1500): Water system pipe and tank insulation and cooling systems line insulation. a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ ❑ CF -6R Form: 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ N ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain El ❑ E]Coefficient ❑ (SHGC), and infiltration certification. EnergyPro 4.4 by EnergySoft User Number: 1268 Job Number: 08-054 Page:6 of 9 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ 1K ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ 0 ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ EK ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑x ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. ❑ Q ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑x ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 1268 Job Number: 08-054 Page:6 of 9 Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1 R NOTE: Lowdse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check WA if not ENFORCE- aoolicahle_ WA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 65; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely In conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ © ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Nonelectrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ FAI ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ 0 ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ftj OR are controlled by a dimmer switch OR are controlled El lil El by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ [i] ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)B: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 1268 Job Number: 08-054 Page:7 of 9 Residential Kitchen Lighting Worksheet WS -5R Fire Restoration For Zuniga 6/23/2008 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (4) 4 ft Fluorescent T8 Rapid Start Elec Yes X No 114.0 x 1 = 114 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 114 B: 0 COMPLIES IF A >_ B YES ® NO ❑ EnergyPro 4.4 by EnergySoft User Number: 1268 Job Number: 08-054 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Fire Restoration For Zuni a 6/23/2008 SYSTEM NAME FLOOR AREA Alt HVAC System 883 Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sqft) 40.8 Cooling System Output per System 31,550 Total Output (Btuh) 31,550 Total Output (Tons) 2.6 Total Output (Btuh/sgft) 35.7 Total Output (sgft/Ton) 335.8 Air System CFM per System 1,150 Airflow, (cfm) 1,150 Airflow (cfm/sgft) 1.30 Airflow (cfm/Ton) 437.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above aiven at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I I CFM I Sensible 971 18,281 1,477 646 17,884 0 3,002 2,090 0 0 0 0 0 0 0 0 0 3,0021 1 2,090 24,2851 1,4771 22 063 3-T 80% AFUE 14.0 SEER 115F osa 27,653 500 36,000 Total Adjusted System Output 27 653 500 3s,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 p, Jan 12 am -earn Temoeratures at Time of Heatina Peak) 26.0 OF 68.3 OF 68.30E 97.7 OF O Supply Air Ducts Outside Air 0 cfm 96.0 of Supply Fan Heating Coil All k. 1150 cfm ROOMS 70.0 OF 68.3 OF ( �% Retum Air Ducts 4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6 OF 80.5/64.9 OF 80.5/64.9OF 57.9/56.6 OF O 4 Supply Air Ducts ' Outside Air 0 cfm Supply Fan Cooling Coil 60.3 / 57.5 OF 1150 cfm 47.2% R.H. ROOMS 80.5/64.9 OF 78.0 / 64.1 OF I Return Air Ducts `Src EnergyPro 4.4 by EnergySoft User Number: 1268 Job Number: 08-054 Page:9 of 9