Loading...
08-0424 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 08-00000424 Property Address: ; 51780 AVENIDA HERRERA '1 APN: 1773-173-002-23 -000000- Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: COVE RESIDENTIAL Application valuation: 98370 Applicant: Architect or Engineer: A ----------------- LICENSED CONTRACTOR'S DECLARATION IG & SAFETY DEPARTMENT BUILDING PERMIT Ihereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: - License No.: Date: Contractor: OWNER -BUILDER DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work.himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). •� 1�1 1, as owner of the property, am exclusively_ contracting with licensed contractors to construct the project (Sec. —� 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) II am exempt under Sec. , B.&P.C. for this reason Date. n�iGo•��,dS Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERA11T VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/21/08 Owner: AGUILLON HECTOR AQUINO 53429 LA PAZ COACHELLA, CA 92236 Other struct ink. . . . . . C Contractor: Owner61 (� APR - I k._.! • WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers'_ compensation insurance carrier and policy number are: Carrier 4 . 00 Policy Number NO I certify that, in the performance of the work for which this permit is issued, I shall.not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code II f hwith comply with those provisions. -� - -� Date:ry%.,�e?oP Ap'plican't: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. , 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for insp ion purposes. I f DateC3l� ?� Signature (Applicant or Agent):y a Application Number . . . . . 08-00000424 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 635.00 Plan Check Fee 412.75 Issue Date Valuation . . . . 98370 Expiration Date 10/18/08 Qty Unit Charge Per Extension BASE FEE 414.50 49.00 ---------------------------------------------------------------------------- 4.5000 THOU BLDG 50,001-100,000 220.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 78.59 Plan Check Fee 19.65 Issue Date . . Valuation . . . . 0 Expiration Date 10/18/08 Qty Unit Charge Per Extension BASE FEE 15.00 1522.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 53.27 516.00 ------------- -------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 10.32 Permit . . . MECHANICAL Additional desc . Permit Fee 52.50 Plan Check Fee 13.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/18/08 Qty Unit Charge -Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 6.5000 EA MECH VENT FAN 13:00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit PLUMBING Additional desc . Permit Fee 76.50 Plan Check Fee 19.13 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/18/08 Qty Unit Charge Per Extension BASE FEE 15.00 7.00 6.0000 EA PLB FIXTURE 42.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 LQPLIL\IIT Application Number . . . 08-00000424 Permit . . . . . .. PLUMBING Qty Unit Charge Per Extension 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 3.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 9.00 ---------------------------------------------------------------------------- Special Notes and Comments HOUSE DESTROYED DUE TO.FIRE . REBUILD .OLD SQ. FTG. 1303 AND 219 SQ. FT. ADDITION WITH 516 SQ. FT. GARAGE AND 90 SQ. FT. PATIO. USE EXISTION SLAB PER • ENGINEER OF RECORD.HOUSE TO BE REBUILT BY OWNER BUILDER. -------------------------------------- ------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 41.28 STRONG MOTION (SMI) - RES 9.83 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 842.59 .00 .00 842.59 Plan Check Total 464.66 .00 .00 464.66 Other Fee Total 51.11 .00 .00 51.11 Grand Total 1358.36 .00 .00 1358.36 LQPERbIIT TELEPHONE (760) 777-7012 FAX (760) 777-7011 OWNER/BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "Owner/Builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the City or County. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200.00 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. If ycra are an employer, you must register with the State and Federal Government as an employer and you are subject to several obligations include State and Federal income tax withholding, federal social security taxes, worker's compensation insurance, disability insurance costs and unemployment compensation contributions. There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. For more specific information about your obligations under Federal Law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contracts are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "Owner/Builder" building permit, erroneously implying that the property owner is providing -his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N. Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Very truly yours, CITY OF LA QUINTA DEPT. OF BUILDING AND SAFETY 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7012 FAX: (/7660) 777-7011 OWNER'S SIGNATURE/DATE PROPERTY ADDRESS 9? PERMIT NUMBER(S) �r 07 111 CITY OF LA QUINTA'SUB-CONTRA_ CTOR LIST. JOB ADDRESPERMIT NUMBER 08--, K2<1 OWNER / ���� BUILDER O -A --,e-1-9 r This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. Classification Trade /Class _._t . r tore :: :;. ac __. ::::<::::":;::':>State'.::Contractor's Licenrs... _ :: ::< e... Worker oh.: City Business License: <. . Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date License Number (xx/xx/xx) (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C-12) CONCRETE (C-8) RAMING :I076) % 753 rz-a-) /-/-OQ/ 1015 STRUCT..STEEL 1C-51) MASONRY (C-29) PLUMBING (C -36) g �f'J w1 b! ✓1 C 3 (o7 9 7 D 9 4. 7 2 00,7 !p % ZG LATH; PLASTER (C77*35)i /3 6q oP Al 13 7 0 DRYWALL (C-9) : Y � L 5^ Z3 -30- 5, e �— 3 yo `- 31 i 6 o i _ /z o� HVAC. (C-20 :: / r ' i C . 20 J s� /-3/ _ '� j�5o.5 i�-� kA i u9C 10 2-1 as p ''• /2 LECTRICAL. (C-101' : .: - RQOFING'.IC.'391::.:.':.::;::>`. !C �`.%L/G �'uG' v�� 1� �'•/" �j `'�� �Q a " C , / 3! - udv ren. ftl£ ti �'f3 �j7 t Q ui I a t T l �� 75" I SHEET.METAL (.0 3)" FLOORING I GLAZING (C-17} T INSULATION'(C-2) . �+ SEWAGE DISP; (0-42)' PAINTING (6=33) L t]J�WJ2 Y' CERAMIC TILE (C-54) ruj A'J. Y' CABINETS (0-6) 0 o . FENCING (C-13) LANDSCAPING (C=27.) POOL (C-53) f CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDADUNES O Date 4/21/08 La Quinta, CA 92253 In RANCHO MIRAGE INDIAN WELLS �. No. 30011 (760) 771-8515 PALM DESER"r LAQUINTA 4y I-NQINDIO yr3 0 Owner Aquino APN # 773-173-002 Address Jurisdiction La Quinta City Zip Permit # Tract # No. of Units 1 Type Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 51780 Avenida Herrera 1522 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments 1,303 sf destroyed by fire. 219 sq ft addition. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Fire Damage/Demo. Replacement This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 1,522 S.F. or $0.00 have been paid for the property listed above and that .building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Miguel Perales Check No. Name on the check Telephone Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collected /exempte by S r n G' v y Payment Recd ,Over/Urider_ Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this w s e to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting b • JHA 'ENGINEERING, LNC CON SULTIN G CIVIL EN G INEERS • SURVEYIN G February 13, 2008 City of La Quinta , Building Department Re: Hector A. Aquino 51780 Avenida Herrera La Quinta, California Re: Rebuilding of fire damaged home An ins e P a on the frame ection was made e and foundation on the above site. While the steel studs in the walls were in good condition the tops showed a little damage. In addition the new code requires the live load on the roof be 20# per square foot instead of the 16# per square foot in the original design. This additional load exceeds the allowable loading on the existing studs. It was the recommendation of this office that the walls be removed and the building can be reconstructed using wood studs. The concrete foundation is in good condition and can be saved. Respectfull John H. Hacker P.E. C 14614 * " EXP 03.31 CIV I� �TFOFC AIIF�Q- 41921 BEACON HILL • SUITE A • PALM DESERT, CA. 92211 (760) 779.0657 ' FAX (760) 779-5143 TITLE 24 REPORT v OFFKE CO Title 24.Re.port for: Mr. Hector A. Aquino 51780 Avenida Herrera La Quinta, CA Project Designer: Design Concepts CI � OF QUINTA By: BUILDING & 1M rep red BUILD APPR � Ha ker FOR CONST Insu-form, Inc. B�a�ot--H ill, Suite A GATES-= esert, CA 92211 (760) 779-0657 Job Number: 1522 Date: 4/21 /2008 The-EnergyPro-computer-program-has-been-used to perform the calculations summarized in this compliance report. authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building This program has approval and is Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: 1522 User Number: 2655 TABLE OF CONTENTS OAG Olk ry . )It I, Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 Form WS -5R Residential Kitchen Lighting 9 HVAC System Heating and Cooling Loads Summary 10 Room Load Summary 11 EnergyPro 4.4 by Energysoft Job Number: 1522 User Number: 2655 Certificate'Of Compliance : Residential (Part 1 of 4) CF -1 R Mr Hector A Ac}uinr) Project Title 51780 Avenida Herrera I a Quinta 4/21/2008 Date Project Address Building Permit # Inst -fi irm Inr (760) 779-0657 Documentation Author Telephone Plan Check/Date FneravPrQ Compli-66ce Method CA Climate %One 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 0.83 0.30 0.54 Space Cooling 51.03 47.49 3.55 Fans 7.25 7.26 -0.02 Domestic Hot Water 13.52 15.31 -1.79 Pumps 0.00 0.00 0.00 Totals 72.63 70.36 better than Standard: Building Type: [j] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (W) 270 deg Natural Gas Area: 158 ft 2 Avg. U: 0.59 2.27 3.1% Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Ratio: 10.4% Avg. SHGC: 0.76 Number of Stories: BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume Units Zone Type Type RESH\/AC X522 12�17R 1 nn ronde_iined 4Pthack OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wand 1 522 n n25 R-38 R -n n _0 10 Wall Wonr1 204 n 074 R-13 R-4 5 _n gn Wall Wood 264n_�7a _ R=13 R-4 5 PQ_gp Wall Wnnd 338 nn 074 R_13 RA 5 �Rn gn wall Wood 240 n_074 R_13 R-4 5 ?7n gn Door Nnne 20 0,500 Insul R_n n 27n 90 1,522 ft2 n/a ft2 0 ft2 1,522 ft2 8.0 ft 1.00 1 Vent Hgt. Area —� n/a Gains Condition Y / N Status JA IV Reference Location / Comments IN ❑New 01-A18 RFS 7QNF ® EJ New— 09-A3 RFS 70NE ® El New 09-A3 RES 70NE ® ❑New n9 -A3 RFS 7nNF ® [:1 New_ 09-A3 RES 70NE ® ❑New 28-A3 RES 7QNF ❑❑❑❑ ❑❑❑❑ F-1 F-1 ❑❑o ❑❑ ❑❑ nn I EnergyPro 4.4 by EnergySoft User Number. 2655 Job Number: 1522 Paae:3 of 11 I Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Mr. Hector A. Aquino 4/21/2008 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments Len. Winrinw I eff (N) 160 Q 59p NFRC n 7s NFRC ()_ qO New Viking 1000 1 owF (mac (R) RFS 70NF 2 Window Left (N) 16.0 0.590 NFRC 0_76 NFRC 0 90 New Viking 3000 LowE Gas (R) RES ZONE 5 Window Left (N) 4.0 0.590 NFRC 0_76 NFRC 0 90 New Viking 3000 LowE Gas (R) RES ZONE 4 Window Rear (E) 40.2 0.590 NFRC 0_76 NFRC 90 90 New Viking 3000 LowE Gas (R) RES ZONE 5 Window Rear (E) 16.0 0.590 NFRC 0_76 NFRC 90 90 New Viking 3000 LowE Gas (R) RES ZONE 6 Window Right (SS) 16.0 0.590 NFRC 0.76 NFRC 180 90 New Viking 3000 LowE Gas (R) RES ZONE Z Window Right (S) 16.0 0.590 NFRC 0_76 NFRC 180 90 New Viking 3000 LowE Gas () ) RES ZONE 8 Window Right (S) 16.0 0.590 NFRC 0.76 NFRC 180 90 New Viking 3000 LowE Gas (R) RES ZONE 6 Window Right (S) 4.0 0.590 NFRC J125 NFRC 180 90 New Viking 3000 LowE Gas (R) RES ZONE 1Q Window Front (W) 14.0 0.590 NFRC -QZ6 NFRC 270 -91Z New Viking _3000 LowE Gas (R) RES ZONE 1.0 4.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 5.0 4.0 4.0 0.1 4.0 4.0 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Len. Overhang Hgt. LExt. Left Fin Right Fin REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Woven Sunscreen 0.30 4.0 4.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 1.0 4.0 2.0 0.1 2.0 2.0 4 Woven Sunscreen 0.30 6.7 6.0 2.0 _0. _2_0 2.0 5 Bug Screen 0.76 4.0 4.0 2.0 0 1 2.0 2.0 6 Bug Screen 0.76 4.0 4.0 2.0 0. _2- 2.0 7 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 1.0 4.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 5.0 4.0 4.0 0.1 4.0 4.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 700 3.50 28 0.98 0 26-A1 New RES ZONE / Slab on Grade Concrete, Heavyweight 822 3.50 28 0.98 2 26-A1 New RES ZONE / Slab on Grade Insulation PERIMETER LOSSES Location/ Condition Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 74 None No Insulation 26-A1 New RES ZONE Slab Perimeter 70 None No Insulation . 26-A1 New RES ZONE Run Initiation Time: 04/21/08 09:31:45 Run Code: 1208795505 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: 1522 Page:4 of 11 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Mr. Hector A. Aquino 4/21/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type RES HVAC Central Furnace 92% AFUE Split Air Conditioner 12.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? RES HVAC Ducted Ducted Attic 8.0 New Yes Hydronic Piping. Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor. Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS The plan shows an existing, however the only part of the original house to remain is the foundation so this is a performance calculation. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Design Concepts Address: Telephone: Enforcement Agency Name: Title/Firm: Address: Telephone Lic. #: (signature) (date) Documentation Author Name: John Hacker Title/Firm: I nsu-form. Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Mr. Hector A. Aquino 4/21/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field The Roof 'R-38 Roof Attic" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design - Verify Thermal Mass: 700 sqft Exposed Slab Floor, 3.50" thick at ENTIRE HOUSE HIGH MASS Design - Verify Thermal Mass: 822 sqft Covered Slab Floor, 3.50" thick at ENTIRE HOUSE HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. --Plan7 Field The HVAC System 'RES HVAC' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System 'RES HVAC' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System 'BDP CO. 563AN036-A" includes credit for a 10.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. 1 EnergyNro 4.4 by EneMySoft User Number: 2655 Job Number: 1522 Paoe:6 of 11 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ 0 ❑ •§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑x ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ 0 ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ RX ❑ CF -6R Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/ExFltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ rxi ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ 11Coefficient (SHGC), and infiltration certification. ❑ ❑ ❑ 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ 0 ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ 0 ❑ § 150Q): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ 0 ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ Q ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ Q ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1506. ❑ ❑X ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: 1522 Page:7 of 11 Mandatory Measures Summary: Residential (Page 2 of 2) MF-1 R' NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X El sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support - platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ Eil ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ R ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ X❑ ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ El ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: 1522 Page:8 of 11 P Residential Kitchen Lighting Worksheet WS -5R Mr. Hector A. Aquino 4/21/2008 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (2) 4 ft Fluorescent T8 MagEE Yes X No 70.0 x 1 = 70 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes- No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 70 B: COMPLIES IF A;-> B YES ® NO ❑ EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: 1522 Page:9 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 777] PROJECT NAME DATE Mr. Hector A. Aquino 4/21/2008 SYSTEM NAME FLOOR AREA RES HVAC 1,522 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sqft) 36.8 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sqft) 23.0 Total Output (sgft/Ton) 521.8 Air System CFM per System 1,300 Airflow (cfm) 1,300 Airflow (cfm/sqft) 0.85 Airflow (cfm/Ton) 445.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,26 16,415 2,588 477 19,516 0 1,356 1,397 0 0 0 0 0 0 0 0 0 1,356 1,397 19,1261 2,5881 F---22,3110 BDP CO. 563AN036-A 19,628 12,297 56,000 Total Adjusted System Output 19 628 12,297 56,000 (Adjusted for Peak Design Ccnditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 69.0 of 69.0 of 108.9 of O Supply Air Ducts Outside Air 0 cfm 107.9 of Supply Fan Heating Coil 1300 cfm ROOMS 70.0 of 69.0 of I 11 110.1 /78.3OF 76.0/66.2OF Outside Air O 0 cfm Supply Far 1300 cfm 76.0/66.2 of h Return Air Ducts 4 76.0 / 66.0 of W 62.0 / 61.0 of Cooling Coil h Return Air Ducts 'I Supply Air Ducts 62.9 / 61.3 of 62.2% R.H. ROOMS 75.0 / 65.9 of I EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number: 1522 Paae:10 of 11 I ]ROOM LOAD SUMMARY PROJECT NAME Mr. Hector A. Aquino DATE 4/21/2008 SYSTEM NAME RES HVAC FLOOR AREA 1,522 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE AME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE RES ZONE ENTIRE HOUSE 1 1,261 16,415 2,588 1,261 16,415 2,588 477 19,516 PAGE TOTAL 1 1,261 16,4151 2,588 477 19,5161 TOTAL 1 1,261 16,415 2,588 477 19,516 EnergyPro 4.4 by EnergySoft User Number: 2655 Job Number. 1522 Page: 11 of 11