13072 (SFD)Building
Address 52-1
Owner
La Quinta Cove Home, Inc.
Mailing
Address 310 Wa.Shington, Ste. 9214
City lZip
Legal Description
Project Description SFD.
State Lic. City74 -
& Class if. Lic. # ,;r (
Arch., Engr., ' Barr A, Berkus AIA 7
Designer 1' +
Address Tel.
2.23 Be Lie Guerra _
City Zip State
Santa Sarbara + CA 93101 Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am Jicensed under provisions of Chapter 9 (commencing with Section
7000)'_ Division 3 of the -Business and Professions Code, and my license is in full force and
DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions* Code: Any city or county which requires a
permit to construct• alter• improve, demolish, or' repair any structure, prior to its issuance also
requires the applicant for such permit to rile a'signed statement that he is licensed pursuant to
the provisions of the Contractors License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(S) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C., for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
Ihereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
. O Copy is filed with the city. ❑ Certified copy is hereby furnished.
'CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
13072
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
Sq. Ft. ;r�i94
Size
No. No. Dw.
Stories • Units
New [k Add ❑
Alter ❑ Repair ❑ Demolition ❑
Permit does
not include any block walls
pool.
Estimated Valuation
$99,559.00
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
541.44
Const.
639.50
Mech.
62.00
Electrical N , ,
r. 132.75
Plumbing
144.00
.S.M.I.
10.00
Grading
20.00
Driveway Enc.
—(—
Infrastructure
2,201.83
Precise -Lan 25.00
TOTAL
3,777.02
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SO. FT. ® $
UNITS
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
YARD SPKLR SYSTEM
2 ND FL. SO. FT. p
HEATING (ROUGH)
STORAGE TANK
FORMS /
MOBILEHOME SVC.
BAR SINK
POR. SO. FT. Q
DUCT WORK
ROCK STORAGE
GAR. SO. FT. p
POWER OUTLET
ROOF DRAINS
METER LOOP
HEATING (FINAL)
DRAINAGE PIPING
CAR P. I SO. FT. ®
GAS (FINAL)
WALL SO. FT. ®
DRINKING FOUNTAIN
SO. FT. ®
WATER HEATER
URINAL
ESTIMATED CONSTRUCTION VALUATION $ .
FINAL INSP.
WATER PIPING
NOTE: NoYto be used as property tax valuation
WATER SYSTEM
FLOOR DRAIN
MECHANICAL FEES
GRADING
cu. yd.
$ plus x$
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASH ER(AUTO)(DISH)
APPLIANCE DRYER
FINAL INSP. //Ll (,
[
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
^ , �( R (2��
LAUNDRY TRAY
AIR HANDLING UNIT CFM
REMARKS:
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ®c
BATH TUB
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID ® 1+/4 c
SEWAGE DISPOSAL
SO.FT.GAR ® 3/4c
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS /
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH) !y /�
cr
METER LOOP
HEATING (FINAL)
OTHER APPJEQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
_ $
LUMBER GR.
FINAL INSP.
FRAMING O a7•p Q
!!�J
FINAL INSP. //Ll (,
[
,(�
ROOFING ?i �0
^ , �( R (2��
j/y� 0�
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL —� Lp
LATHING -93 y0
MESH
INSULATION/SOUND �7 �f3 4
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS
GARDEN WALL FINAL
Trtt
A q , panj�g
T4 Pf Ila ( 'Qu-tuta
U it, tb in� dub $afet� 31t11t*.!5t*1011
iI
This Certificate, issued pursuant to the requirements of Section 306 of the Uniform Building!
Code certifying that at the time of issuance this structure was in compliance with the various
ordinances of the City regulating building construction or use. For the following:
BUILDING ADDRESS 52-125 Avenida Herrera I! { i! ;;•, I
Single Family Dwelling
Use Classification Bldg. Permit No. 13072
Group R3 Type Construction VN Fre Zone Use Zone SR
La Quinta Cove Home, Inc. 310 Washington, Ste. P214
Owner of Building Address,
Cit Santa Monica, CA 90292
City Lonnie Day ('
By: .
'Dote: January 14, 1994
Building Official
POST 114 A CON01000US PLACE —
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201 .
Document Cannot Be Duplicated 619-775-3500
Date 6/23/93 1 Type of Permit La Quinta
No. 112286 Permit #
Log 71
Owner Name La Quinta Cove Home, Inc.
No. Street See Below
city La Quinta Zlp 92253 Study Area 113
APN # I Tract # Lot # 0 Square Footage 115246
Type of Development I Single Family Residence I No. of units 0
Comments 53-683 Avenida Alvardo, 52-415 Avenida Mendoza, 52-140 Avenida Velasco,
52-675 Avenida Rubin, 52-375 Avenida Navarro, 52-780 Avenida C'arranza,
53-R1(l Villa 4? -174 Avenida HPrrPra ql-?74 AuPniria Mar+inP7
At the present time, the Desert Sands Unified School District does not collect fees on
garages/ carports, covered patios/ walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of 1.65 x 15 246 or $ 25,155.90. have been paid to. D.S.U.S.D. for
theproperty listed above and that building permits and/or Certificates of-0ccupancy,'for ..
this square footage in this proposed project may now be issued.
Fees Paid By La Quinta Cove Home, Inc. Telephone 564-5540
Name on the check
By James F. Lively
Assistant Superintendent, Business Services
Fee collected /exempted by Vickie J. Durrett
�" � Payment Received
,
Signature Z'
'Chick Mo. 054138
Collector. Attach a copy of county or city plan check application form to district ropy for all waivers.
Embossed Original- Building Dept. /Applicant Copy - Applicant/Receipt Capy - Accounting
Title 24 Report For:
HARLAN LEE
THE COVE
92259M
December 3, 1992
These plans and calculations comply substantially with the 1992
California Energy Commission Regulations for Residential
Buildings:: Title 24; Parts 1 and 6
Richard A. Palmer Energy Management Engineering, Inc.
'.1910 E. Warner, Suite A -
Santa Ana, CA 92705
(714) 261-5704
ORDER OF CONTENTS
1. Instructions for Compliance Documentation
2. CF -1R Forms (Certificates of Compliance)
3. MF1 Forms (Mandatory Measures Checklist)
4. Title 24 Lighting Requirements
5. Forms 3R (Construction Assemblies)
6. C -2R Forms (Computer Method Summary)
7. Heating and Cooling Calcs
INSTRUCTIONS FOR COMPLIANCE DOCUMENTATION
These calculations reflect the new 1992 Second Generation Residential Energy
Standards. Numerous changes have been incorporated into the new procedures,
including the documentation which is required to be incorporated into the plans. To
minimize plan check and field problems, the following information should be put on
the plans:
1. CF -1R Form (Certificate of Compliance):
Each plan must have a CF -1R Form submitted with the calcs, as well as on the
drawings. The form, developed by the CEC, summarizes the energy conservation
features required for compliance. The CF -1R Form is 3 pages per plan, the third
page being a signature page for owner, architect and energy consultant to sign.
Though all three sheets for each plan must be submitted with the talcs, we
recommend putting only one page for signatures on the plans. This reduces
redundancy in signing. Whether the plans must be wet signed or not will vary
depending on the building department.
2. MF -1R Form (Mandatory Measures. Checklist):
This is a one page checklist of building features that are required of all residential
buildings built in California. These must be on the plans as well as in the calcs.
3. A Heating and Cooling Load Summary must be provided. It has
been incorporated as the second page of the CF -1R.
4. The convention for Orientation description is as follows:
Direction
(Clockwise Rotation)
Orientation 1: Front to North
Orientation 2: Front to East
Orientation 3: Front to South
Orientation 4: Front to West
Azimuth
0 degrees
90 degrees
180 degrees
270 degrees
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title: THE COVE
Project Address: LA QUINTA
HARLANIEE
Documentation Author:
Company: R. A. Palmer & Associates
Telephone: (714) 261-5704
Compliance Method: MICROPAS4 by Enercomp, Inc.
Climate Zone: 15
Date: 12/ 3/1992.
Building Permit #
Plan Check / Date
Field Check/ Date
MICROPAS4 v4.00 File -92259M11 Weather -15 Program -FORM CF -1 R
User#-MP0265 User -Richard A. Palmer & Associates PLAN 1
GENERAL INFORMATION
BUILDING SHELL INSULATION
Conditioned Floor Area:
1694
Component
Insul Assembly
Tank
Building Type:
Single
Type
R -value U -value
Location/Comments
Building Front Orientation:
Cardinal
(gal)
Rwalue
Number of Dwelling Units:
1
SlabEdge
0 0.72
No Insul
Number of Stories:
1
SlabEdge
0 0.50
R-7 Equiv.
Floor Construction Type:
SlabOnGrade
Wall
15 0.081
ext
Infiltration Control:
Standard
Wall
15 0.075
garage
Roof
30 0.033
attic
THERMAL MASS
Area
Thickness
Cvr R -Val
Type (sf)
(in)
0 s Exposed
Location/Comments
SlabOnGrade 56
3.5
0.0
kitchen
SlabOnGrade 75
3.5
0.0
entry
SlabOnGrade 24
3.5
0.0
bath 2
SlabOnGrade 8
3.5
0.0
fireplace hearth
SlabOnGrade 1521
3.5
2.0
carpeted slab
WATER HEATING SYSTEMS
Number
Tank
External
In Energy
Size
Insulation
System Type Heater Type Distribution Type System Factor
(gal)
Rwalue
Storage Gas Standard 1 0.60
50
6
Manufacturer and Model #: American GV2F90-533T (or approved equal)
SPECIAL FEATURES/REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1 R
Project Title: THE COVE Date: 12/ 3/1992
Project Address: LA QUINTA / HARLAN LEE
MICROPAS4 v4.00 File -92259M11 Weather -15 Program -FORM CF -1R
User#-MP0265 User -Richard A. Palmer & Associates PLAN 1
GLAZING
Glazing
Area
U-
# of
Interior Exterior
Framing
Orientation
(sf)
value
Panes
Shading Shading
Overhang
Type
ENT
Front
5
0.57
2
none
6
Metal
DEN
Front
30
0.82
2
Roller.Wht
1
Metal
BRS
Left
50
0.82
2
Roller.Wht
1
Metal
MBA
Left
6
0.82
2
Roller.Wht
1
Metal
MBA2
Back
5
0.82
2
Roller.Wht
1
Metal
MBR
Back
15
0.82
2
Roller.Wht
1
Metal
SLDR
Back
53.4
0.72
2
Roller.Wht
1
Metal
UV2
Back
16
0.57
2
none
1
Metal
LIV3
Back
10
0.82
2
Roller.Wht
1
Metal
SLDR2
Right
53.4
0.72
2
Roller.Wht
1
Metal
LIV DIN
Right
40
0.82
2
Roller.Wht
1
Metal
KIT
Right
10.5
0.82
2
Roller.Wht
1
Metal
DEN2
Right
12.5
0.82
2
Roller.Wht
.1
Metal
ASSUMED HVAC SYSTEMS
Assumed Duct
Duct
Assumed System
Efficiency Location
R -value
Gas
0.78
Attic
4.2
AirCond
11.0
Attic
4.2
ACTUAL HVAC SYSTEMS
HEATING LOAD:
HEATING EQUIP:
COOLING LOAD:
COOLING EQUIP:
PLAN:
1
38931 BTUH STD
CARRIER 58PAV075JC 36400 SENS 0112 F
CARRIER
38TMO48
60953 BTUH MAX
80.0
(78% MIN)
47320 BTUH TOTAL
CARRIER
CD5AA048 .
71000 BTUH
3.94 TONS
39450 STUN 0 ARI
11.00 SEER(11.0 MIN)
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title: THE COVE Date: 12/ 3/1992
Project Address: LA QUINTA / HARLAN LEE
MICROPAS4 v4.00 File -92259M11 Weather -15 Program -FORM CF -1 R
User#-MP0265 User -Richard A. Palmer & Associates
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed
to comply with Title 24, parts 1 and 5 of the califomia Code of Regulations, and the administrative
regulations to implement them. This certificate has been signed by the individual with overall
design responsibility. When this certificate of compliance is submitted for a single building
plan to be built in multiple orientations, any shading feature that is varied is indicated in the
Special Features/ Remarks section.
OWNER
Name:
Company- HARLAN LEE
Address: 310 WASHINGTON BLVD
MARINA DEL REY CA 90292
Phone: 310 827-0171
License:
Signed:
Date:
I
DOCUMENTATION AUTHOR
Name: R. A. Palmer
Company: Richard A. Palmer Assoc.
Address: 1910 E Wa
Santa
Phone: (714) k P4 �y
Signed:
ca
Date:
. •. Jlq �ECHAN��P� ��Q
EOF
CAVE
Name:
Title:
Agency:
Phone:
Signed:
Date:
ENFORCEMENT AGENCY
r4andatory Measures Checklist: Residential
MF -1 R
NOTE: t_owfise rosidontial cuildings subject to the Standards must contain these measures regardless of the compliance
approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements
:istod or, the Cani;icato of Compliance. When this checklist is incorporated into the permit documents, the features
noted shalt be ccnsidered by all panies as binding minimum component performance specifications for the
mandatory moasures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION DESIGNER ENFORCEMENT
Building Envelope Measures X
§I50(a): Minimum R•19 ceilino insulation, X
§150(b): Loose fill insulation manufacturer's labeled R -Value. X
• §150(c): Minimum A-13 wall insulation in trained walls (does not apply to exterior mass walls). X
• §I 50(d): Minimum R.13 raised Boor insulation in framed floors; minimum R-8 in concrete raised floors. X
§150(): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no N/A
greater than 2.0 penn/inch.
§118: Insulation specified or installed meets Cafifomia Energy Commission quality standards. X
Indicate type and form.
§116-17: Fenestration Products, Exterior Doors and InfiltrationlExfiltration Controls
a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
b. Manufactured fenestration products have label with certified U -value, and infiltration certification.
c. Exterior doors arid windows weathastripped: all joints and penetrations caulked and sealed. X
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. X
§150(f): Special infiltration, barrier installed to comply with §151 meets Commission quality standards. iu / A
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Ings
1. Masonry and factory -built fireplaces have:
a Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures X
§110 -13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X
§150(): Setback thermostat on all applicable heating systems. X .
§150@: Pipe and Tank Insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation
blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater).
2. Fust 5 feet of pipes closest to water heater tang rlon-recirarlaating systems, insulated (R-4 or greater).
..3. All buried or exposed piping insulated in recirwlaling sections of hot water system.
4. Cooling system piping below WF insufated.
',. 5. Piping insulated between heating source and indirect hot water tank X
§150(m): Ducts and Fans
1. Ducts corstruded, installed and sealed t4 comply with UMC Sections 1002 and 1004; ducts insulated
to a minimum installed value of R-4.2 or ducts endosed entirety within conditioned space.
2. Exhaust fan systems have badcdraft or automatic dampers '~
-
3. Gravity ventilating systems serving conditioned space have either automatic or.readily accssstble,
manually operated dampers..
X
§114: Pod and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions,
N/A
no electric resistance heating and no pilot light
2. System is installed with:
N/A '
a At least 36' pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spa
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas-fired central furnace, pod heater, spa healer or household cooking appliance have no
continuously buring pilot light. (Exception: Non -electrical cooking appliance with pilot < 150 Btuthf.)
Lighting Measures
X
§150(k): 40 lumewwatt or greator for general lighting in kitchens and rooms with water closets; and
recessod ceiling fixtures IC (insulation cover) approved.
X
Revlsod January 1992
LIGHTING MEASUIZES
Installing energy-efficient lamps and fixtures can
reduce lighting energy costs without sacrificing the
quality or quantity of light available.
Kitchen Lighting
The Standards require that general lighting in
kitchens have.an efficacy of at least 40 lumens per
wart and be controlled by the most accessible
switch(es) in the kitchen. The light switch location
determines how the occupant will use the lighting.
Luminaires used only for specific decorative
effects (and which are not the only luminaires in
the kitchen) need not meet this requiremenL
B
"A" must be fluoresce it
General lighting is lighting designed to provide a
uniform level of light distribution throughout a
space. This can be achieved by light fixtures in the
ceiling or around the perimeter of the room.
Lighting fixtures under cabinets may meet the
general lighting requirements if they provide
uniform light distribution in the kitchen (see
Figure 2-11). A luminaire which is the only
lighting in a kitchen will be considered general
lighting.
"A" must be fluorescent
All of "C" must be fluorescent "A" or all of "C' must be fluoreseenr
Kitchen Lighting Examples
Bathroom Lighting
The Standards require.that each room containing a
water closet must have at least one luminaire with
lamps with an efficacy of at least 40 lumens per
watt, As an alternative, this requirement may be
met by installing the high efficacy luminaire in an
adjacent room that has complementary plumbing
fixtures.
If there is more than one luminaire in the room, the
high -efficacy luminaire must be switched at an
entrance to the room.
"A" must be fluorescuu
A
Genera!
Luminaires installed to meet the 40 lumens per
watt requirements cannot contain medium base
incandescent lamp sockets, and must be on
separate switches from incandescent lighting.
All incandescent lighting fixtures recessed into
insulated ceilings must be approved for
zero -clearance insulation cover (LC.) by
Underwriters Laboratories or other testing/rating
laboratories recognized by the lntemational
Conference of Building Officials (ICBO).
Recessed lighting fixtures left unir=lated
significantly increase the heat loss and heat gain
through the roof/ceiling arra.
B
"A" must be fluorescent:
"D" can be incandescent
�E
B
A
co
"B or E must bt uorescent
or "E•' muse be fluorescent !r
• Bathroom Lighting Examples
7_li-.-� '._...._• t�,yyxa-�: `r-�.__..:_`-.T.�i.•-_..' - --..—.-•=l vrren.:..a��_.. _..:_. •__ _ _ _
Proposed Construction Assembly: Residential Form 3IZ
Project'ritic
Date
11ruiect Addrec.
Building Permit tt
Ducumentation Author Telephone Chcckcd-Bv / Date
R-15 WALL WS15G
As_ccmhly,\amc Enforcement Agency Use Only
Sketch of Construction Assembly .
Assembly Type:
(check one)
Framing Material:
Framing Size:
FramingSpacing:
Framing Percentage:
(check one)
W211 Weight / sf:
(Package only)
Floor
X Wall
Ceiling/Roof
Wood
2 x 4
16 " O.C.
Wall: X
Floor/Ceiling:
15% (16" o.c.)
12% (24" o.c )
10% (16" ox-)
7% (24" o.c.)
List of Construction Components
R -Value
Cavity(Rc)
Frame(Rf)
Outside Surface Air Film
0.17
0.17
1. STUCCO
0.18
0.18
2. R-15 INSULATION
15.00
3. BUILDING PAPIER
0.06
0.06
4. 2 X 4 FRAMING
3.46
5. 112" GYPSUM
0.45
0.45
6.
I;
7.
- Inside Surfacc Air Film
0.68
0.68
T _
Total Unadjusted R -Values:
16 54
5.00
Framing Adjustment Calculation (if applicable):
( 1/16.54 x 1-15/100 ) + ( 1/5-.00 x 15/100
) =
0.081
I/Re 1-(Fr9d/100) 1/Rf Fr%/100
Total U -Value
12.35
1/rotal U -Value
Total R -Value
Proposed Construction Assembly: Residential Fortn 3R
rroject Tittc
11roject Address
Documentation Author Tcscpheac
R— 1 5 GARAGE WALL MCI 15 C,
Asscmhly Name
Sketch or Construction Assembly
List of Construction Components
Outside Surface Air Film
Dau
Building Permit r
Checked BvLDate
Enforcement Agrncy Use Only
Assembly Tvpe_
Floor
(check one)
x Wall
Cr.iling/RooC
Framing Material:
Wood
Framing Size:
2 x 4
Framing Spacing.
16 ' O.C.
Framing Percentage:
Wall- X
15% (16" ox-)
(check one)
12% (24' o.e..)
Floor/CeiTmg:
10% (16- ox-)
7% (24" o.c.)
Wall Weight / sf--
(Packages only)
2. R-15 INSULATION
3. BUILDING PAVER
4. 2 X 4 FRAMING
5- 112" GYPSUM -
6.
7.
Inside Surface Air Film ,•';
Total Unadjusted R -Values:
Framing Adjustment Calculation (if applicable):
R -Value
Cavitv(R )
0.68
0„45
15.00
0.06
0.45
n I Ast
17.32
Re
(
1/ 17.32 x 1-15/10.0 ) + 1/5.78 x -15/100 ) -
I /Rc 1-(Fr9c/100) 1/R( Fr%/100
lfrotal U -Valu
Frame(Rr)
0.68
0.45
0.06
3.46
0.45
0-68
5-.51
Rr
0.075
Total U -Value
13.34
Total R -Value
COMPUTER ME'T'HOD SUMMARY : Page 1 C=2R
Project Title.......... THE COVE Date ......... 12/03/92
Project Address........ LA QUINTA
HARLAN LEE
Documentation Author... Building Permit
Company ................ Richard A. Palmer & Assoc
Telephone .............. 714 261-5704 Plan Check / Date
.Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone........... 15
MICROPAS4 v4.00 File -92259M11 Wth-CTZ15S92 Program -FORM C -2R
Usert-MP0265 User -Richard A. Palmer & Assoc Run -PLAN 1 I
= MICROPAS4
ENESGY USE
SUMMERY
=
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr).
Design
Design
Margin =
= Space Heating:.........
2.40
2.23
0.17 =,
= Space Cooling..........
30.42
31.99
-1.57 =
= Water Heating..........
13.11.
11.69
1.42 =
= North Total
45.93'
45.91
0.02 =
= Space Heating:.:.......
2.40
2.52-
-0.12 = ..
= Space Cooling..........
30.42
30.06
0.36 _
- Water Heating..........'
13.11
11.69
1.42 = J
= East Total
45.93.
44.27-
1.66 =
= Space Heating..........
2.40
2:28
0.12 =
= Space Cooling...."....:`:
30.42
31.37..
-0.95 =_
= Water Heating..........
13.11
11.69
1.42 =
= South Total
45.93--.___
45.34
0.59 =
= Space Heating......:':::
2.40'--_..
1.96 L
0.44 • _
= Space Cooling.":-:.:.::.' .":
30.42---.
31.80.-
-1.38- .. _
= Water Heating..........
13.11
11.69
1.42.-.-_ _
_
= West Total
45.931=
45.45
_: 0.48 =
_ *** Building 'complies with -`C xmputer Performance
. ..GENERAL INFORMATION .... _
Conditioned Floor.Area.....
1694 sf
_rw
BuildingType...'..: .....
Single Family Detached
_x
Construction Type ...." .....
.:New
Building Front Orientation.
`Cardinal - N,E,S,W
Number of Dwelling Units..."
.1
.....
Number of Building Stories.'
I''
Weather Data Type..:.......
ReducedYear
/4
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.......... THE COVE Date........ 12/03/92
MICROPAS4 v4.00 File-92259Mll Wth-CTZ15S92 Program -FORM C -2R
User4-MP0265 User -Richard A. Palmer & Assoc Run -PLAN 1
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area .............
Ground Floor Area..........
Slab -On -Grade Area:........
Glazing Percentage.. ......
Average Ceiling Height.....
Floor
Area
Zone Type (sf)
HOUSE
Residence 1694
Area
Surface (sf)
HOUSE
3
Wall
110
4
Wall
296
5
Wall
220
6
Wall
340
7
Wall
- 200
8
Roof
1694
Slab On Grade (Package D)
1
16940 cf
1694 sf
1694 sf
1694 sf
18.2 % of FA
10 ft
BUILDING ZONE INFORMA=ON
# of Vent Special
Volume Dwell Cond- Thermostat Height Vent Area
(cf) Units itioned Type (ft) (sf)
16940 1.00 Yes Setback
OPAQUE SURFACES
U- Insul Act Solar. Form 3
value R-val Azm Tilt Gains Reference
0.081.R-15
0
90
Yes
None
0.081
R-15
90
90
Yes
None
0.081.R--15
180
90
Yes
None
0.081
R-15
270
90
Yes
None
0.075
R-15
0
90
No
None
0.033
R-30
0
27
Yes
None
PERIMETER LOSSES
Length F2 Insul
2.0 n/a
Location/
Comments
ext
ext
ext
ext
: .. gage
attic
Surface (ft) Factor - R-val Location/Comments
HOUSE
T S1abEdge 159 -.. 0.720 R-
2 S1abEdge :-:25' 0.500 R
FENESTRATI
-0 NO Insul
-0 R-7 Equiv.
ON SURFACES
Area
# of
Frame
Open .
Surface
(sf)
Panes
Type
Type -
HOUSE
Act
Glass
Int
1
Window
6.0
==2
Metal
Fixed
2
Window
30.0
2
Metal
Slider
3
Window
50.0
-.2
Metal
Slider
4
Window
6.0
2
Metal
Slider
5
Window
6.0
2
Metal-
Slider
6
Window
15.0
2
Metal
Slider
-0 NO Insul
-0 R-7 Equiv.
ON SURFACES
_
.SC �..:
SC
Interior .
U-
Act
Glass
Int
Shade
value
Azm
Tilt
Only
Shade
Description
0.67
0
90-0.
0.78
none
0.82
0
90•._0.88
0.40
Roller.Wht,
0.82
90
90.
0.88
0.40
Roller.Wht
.0.82
90
90
.0.88
0.40
Roller•.Wht
0.82
180
90
.'0.88
0.40
Roller.Wht
0.82
180
90
0.88
0.40
Roller.Wht
COMPUTER METHOD SUMMARY Page 3 C -2R
Project'Title.......... THE COVE Date........ 12/03/92
MICROPAS4 v4.00 File -92259M11 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0265 User -Richard A. Palmer & Assoc Run -PLAN 1
OVIIIM �40 V�. ~
Area
Thick
FENESTRATION
Conduct-
SURFACES
Mass Type
(sf)
(in)
Cap
ivity
R -value
Location/Comments
HOUSE
SC
SC
Interior
66
3.5
Area
# of
Frame
kitchen
Open
U-
Act
3.5
Glass
Int
Shade
Surface
(sf)
Panes
Type
3.5
Type
value
Azm
Tilt
Only
Shade Description
7
Door
53.4
2
Metal
fireplace hearth
Slider
0.72
180
90
0.88
0.40 Roller.Wht
8
Window
16.0
2
Metal
Fixed
0.67
180
90
0.88
0.78 none
9
Window
10.0
2
Metal
Slider
0.82
180
90
0.88
0.40 Roller.Wht
10
Door
53.4
2
Metal
Slider
0.72
270
90
0.88
0.40 Roller.Wht
11
Window
40.0
2
Metal
Slider
0.82
270
90
0.88
0.40 Roller.Wht
12
Window
10.5
2
Metal
Slider
0.82
270
90
0.88
0.40 Roller.Wht
13
Window
12.5
2
Metal
Slider
0.82
270
90
0.88
0.40 Roller.Wht
OVERHANGS AND SIDE FINS
--Window--
------Overhang
Left Fin---
Right Fin --
Area
Left
Rght
Surface
(sf)
Hght
Wdth
-Dpth Hght
Ext
Ext
Ext
Dpth
Hght
Ext Dpth Hght
HOUSE
1
Window
6.0
2
n/a
6
2
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
2
Window ,
30.0
5
n/a...
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
3
Window
50.0
5
n/a
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
.4
Window
6.0
3
n/a..
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
5
Window
6.0
1.5
n/a
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
6
Window
15.0
5
n/a
1,
5
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
7
Door
53.4
6.7
n/a
1
6
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
8
Window
16.0
2
n/a
1
4
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
9
Window
10.0
5
n/a
1
'2
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
10
Door
53.4
6.7
n/a
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
it
Window
40.0
5
n/a
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
12
Window
10.5
3.5
n/a
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a.
13
Window
12.5
5
n/a
1
1
n/a
n/a
n/a
n/a
n/a
n/a n/a n/a
OVIIIM �40 V�. ~
Area
Thick
Heat
Conduct-
Surface
Mass Type
(sf)
(in)
Cap
ivity
R -value
Location/Comments
HOUSE
1
SlabOnGrade
66
3.5
28.0
0.98
R-0.0
kitchen
2
S1abOnGrade
75
3.5
28.0
-.0.98
R-0.0
entry
3
S1abOnGrade
24
3.5
28.0
0.98
R-0.0
bath 2
4
S1abOnGrade
8
3.5
28.0
0.98
R-0.0
fireplace hearth
5
S1abOnGrade
1521
3.5
28.0
0.98
R-2.0
carpeted slab
COMPUTER METHOD SUMMARY Page 4 C -2R
Project Title.......... THE COVE Date........ 12/03/92
MICROPAS4 v4.00 File -92259M11 Wth-=15S92 Program -FORM C -2R
I User#-MP0265 User -Richard A. Palmer & Assoc Run -PLAN 1
HVAC SYSTEMS
Minimtnn Duct Duct Duct
System Type Efficiency Location R -value Efficiency
HOUSE
Gas 0.780 AFUE Attic R-4.2 0.830
AirCond 11.00 SEER Attic R-4.2 0.810
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
1 Storage Gas Standard 1 0.60 50 R-6
SPECIAL FEATURES/REMARM
This is a multiple orientation building with no orientation restrictions.
This -printout is for the front facing North.
SLABEDGEI
RICHARD A. PALMER & ASSOCIATES
PAGE 1
4350
4350
RESIDENTIAL CALCULATIONS
25
0.50
475
(ASHRAE METHOD)
FRAMEWALL
966
0.081
DATE:
03 -Dec -92
Tosa =
32
(winter design db) JOB NO:
92259M
Tinside=
70
(winter) CLIENT:
HARLAN LEE
dTEMP =
38
(winter) PROJECT:
THE COVE
AC/HOUR=
0.9
(winter) LOCATION:
LA QUINTA
VOLUME =
16940
(cf) PLAN NO:
1
ATTIC Al
1694
FLOOR AREA:
1694 sf
2253
ROOF R1
---- HEATING LOAD ----
0.051
ITEM
AREA
U -VALUE TRANS. INFILT.
TOTAL
1.13
(sf)
(Btu/h- LOSS LOSS
(Btu/h)
308.8
0.75
sf-F) (Btu/h) (Btu/h)
8801
SLABEDGEI
159
0.72
4350
4350
SLABEDGE2
25
0.50
475
475
FRAMEWALL
966
0.081
2973
2973
PARTFWALL
200
0.075
570
570,
FLR O/GAR
0
0.047
0
0
EXP FIR
0
0.047
0
0
RAISE FLR
0
0:040
0
0
ATTIC Al
1694
0.035
2253
2253
ROOF R1
0
0.051
0
0
GLASSI
0
1.13
0
0
GLASS2
308.8
0.75
8801 ,-.
8801
SKYLIGHTI
0
1.23
0
0
SKYLIGHT2
0
0.7
0 309
0
INFILT.
((ac/h)*(vol)*1.09*dT)/60 10525
10525
* MINIMUM R-4.2 INSULATION REQUIRED ON DUCT IN UNCONDITIONED SPACE
HEAT LOSS: SUM =
29947
STD OUTPUT CAP: SUM*1.3= *
38931
MAX OUTPUT CAP: (SUM+(10*FLOORAREA))*1.3= 60953
-or-, MAX= 45000 Btu/h (whichever
is greater)- 45000
--- SUMMARY OF HEATING AND COOLING LOADS -----
AS CALCULATED BY RICHARD A. PALMER & ASSOCIATES,INC. --
COOLING: FRONT TO NORTHWEST
HEATING @32F ODB
36400 BTUH SENS @112F ODB
29947-BTUH HEAT -LOSS
47320 BTUH TOTAL -
38931 BTUH STD CAP
3.94 TONS 430 SQ.FT/TON 60953 BTUH MAX CAP
—-PROPOSED FURNACE
SELECTION-----,.'
OR STATE APPROVED EQUAL
--;FURNACE MARE & MODEL ..NO: ..__
_, CARRIER. 58PAV075JC -._
-
•AFUE:
80.O..y(78$ MIN) '
OUTPUT CAPACITY:
-- - . 71000 ,BTU/HR
1545 CFM:-.
--—PROPOSED COOLING
EQUIPMENT----_
OR STATE APPROVED EQUAL
CONDENSING -UNIT MAKE & MODEL -NO:
___CARRIER 38TMO48
COOLING COIL -MAKE & MODEL NO:
CARRIER CD5AA048
:.:
TOTAL COOLING CAPACITY:
39450 BTU/HR @ 112
SEASON ENERGY EFFICIENCY RATIO:
11.'00'-SEER(11.0 MIN)
* MINIMUM R-4.2 INSULATION REQUIRED ON DUCT IN UNCONDITIONED SPACE
FRAMEWALL
RICHARD A. PALMER & ASSOCIATES
PAGE 2
38.6
3020
RESIDENTIAL CALCULATIONS
200
0.075
30
(ASHRAE METHOD)
PARTMWALL
0
0
DATE:
03 -Dec -92
Tosa =
112
(summer design db) JOB NO:
92259M
Tinside=
75
(summer) CLIENT:
HARLAN LEE
dTEMP =
37
(summer) PROJECT:
THE COVE
daRange=
34
(summer) LOCATION:
LA QUINTA
AC/HOUR=
0.6
(summer) PLAN NO:
1
VOLUME =
16940
(cf) FLOOR AREA:
1694 sf
0
48
---- COOLING LOAD ----
! RGHT/ FRNT.
ITEM
AREA
U -VALUE EQUIV. TEMP DIFF
TOTAL
0
(sf)
(Btu/hsfF) (deg F)
(Btu/h)
FRAMEWALL
966
0.081
38.6
3020
PARTFWALL
200
0.075
30
450
PARTMWALL
0
0
23.5
0
FLR O/GAR
0
0.047
30
0
EXP FLR
0
0447
30
0
RAISE FLR
0
0.040
30
0
ATTIC Al
1694
0.035
59
3498
ROOF R1
0
0.051
59
0
GLAZING SINGLE SINGLE DUAL DUAL !DRAPED
DIRECTION AREA(sf) FACTOR AREA(sf) FACTOR $NOSHADING
!FRONT
0
58
30
40.
1200
!FRONT/LFT
0
41
0
25
0
!LEFT -
0
58
56
40
2240
!LEFT/BACK"
0
74
.0
55
0.
!BACK
0
66
84.4
48
4051
!BACK/RGHT
0
49
0
33
0
!RIGHT
0
66
116.4
48
5587
! RGHT/ FRNT.
0
74.
0
55
0
SKYLIGHTA
0
186
-.0 ..
152
0
SKYLIGHTB.-...:..
0
186
:" 0
152
0
$ FRONT.
0 ..
82
6
59
354
$FRONT/LFT
0
49-
0 -:.; "
32
0.
$LEFT w : `;
• 0
82
0. -.
59
0
$LEFT/BACK:
0
107
0
81
0
$BACK ." "=: " ;•
0
96
16
72
1152
$BACK/RGHT"
0
66
0
46
0
$RIGHT _;:-; : "' •
770
96
0 '• _..
72
.0
$RGHT/FRNT:.�::.;'
0
,'': 107
0
81
0
INFILT.- :-. 1274.8
2.6
3314
-or-:,, '-'((ac/h) * (vol)
*1..09.*dT) /60 ."
6832
6832. ,,
KITCHEN/LAUNDRY:
1200.
LIGHTS: �.....
-5":
341.3:(#rm)*(341.3/rm)-'"
1707
PEOPLE:
.4
450
..(#bdrm) * (450/bdrm)
1800.
SUBTOTAL::.'::...
SUM
=
33091
DUCT HEAT•.GAIN:
SUM*0.10
_
3309
SENSIBLE LOAD:
SUM+DUCT
GAIN _
36400
LATENT LOAD:
SENS.LOAD*0.3 = -
10920 .
TOTAL: _ :...
SENS I BLE+LATENT = -
47320
RICHARD A. PALMER & ASSOCIATES PAGE 3
RESIDENTIAL CALCULATIONS
(ASHRAE METHOD)
DATE: 03 -Dec -92
PROJECT: THE COVE JOB NO: 92259M
LOCATION: LA QUINTA CLIENT: HARLAN LEE
PLAN NO: 1
FLOOR AREA: 1694 sf
-- COOLING LOAD SUMMARY
BY ORIENTATION --
FRONT TO
NORTH
FRONT TO
NORTHEAST
35697
BTU/HR
SENSIBLE
35869
BTU/HR
SENSIBLE
46406
BTU/HR
TOTAL
46629
BTU/HR
TOTAL
3.87
TONS
3.89
TONS
FRONT TO
EAST
FRONT TO
SOUTHEAST
34473
BTU/HR
SENSIBLE.
35247
BTU/HR
SENSIBLE
44814
BTU/HR
TOTAL
45821
BTU/HR
TOTAL
3.73
TONS
3.82
TONS
FRONT TO
SOUTH
FRONT TO
SOUTHWEST
35064
BTU/HR
SENSIBLE
35779
BTU/HR
SENSIBLE
45584
BTU/HR
TOTAL
46512
BTU/HR
TOTAL
3.80
TONS
3.88
TONS
FRONT TO
WEST
FRONT TO
NORTHWEST
35004
BTU/HR
SENSIBLE
36400
BTU/HR
SENSIBLE
45505
BTU/HR
TOTAL
47320
BTU/HR
TOTAL
3.79
TONS
3.94
TONS
11 :-l_1Hl'1 BARRY H BERKL I' ; HIH
ii,aR(Z��A.BFKKUS
August 16, 1993
Harlan Lee & Associates
310 Washington boulevard
Marina Del Rey, CA 90292.
Attn: Randy
Dear Randy:
Per our phone conversation, I would like to clarify the location of the footing omission described in the
letter from Carl Schneider on August 12, 1993,
1. Due to the fact that the 3 -point bearing trusses have been redesigned as 2 -point bearing
trusses, the footing rwu-dng the length of the house dividing the LIVING/DINING areas
from the SLEEPING areas may be onvtted. (not required)
If you have any further questions, please call.
Sincerely,
Barry A. Berkus, A.I.A.
Soon Branch
J;
�l�t1Y r� LA Q- UI NTA rr
223 L. UO La Guerra
tianta (Jar0afa. CA 9310.1
Y..U5�9ti3-tS:�U'I
Fax: 8U5r966.6846
P. 2/2
I
JUL 13 'T-
11:22AM'-BARRY A BERKUS AIA c IP.i/2
I ® ii
9'2
YL
>
Fl -
7=t 1 7,5517
N
IIE5
ACCEp-'ED FOR
SUBJEC F TO INS!
1t/2" 2911 u
AND
&L 4
DATE q
401011
C= e I IK Irl A --rT /1K I Pf A K I
51 ic
3 ' '
E P- 1 0- 9 S F R I 1 S 1 3 G O U V I S. E N 'G I N E E R I N G P_
G 0 U V I S I N G I N E E R I N C
Ed NEWPORT BEACH • SAN. DIEGO PALM SPRING:
September 10, 1993
Harlan Lee and Associates
78-200 Calle Fortuna '
La quinta, CA 92253
Attn: Randy Wessman
Re: The Cove
Missing Holdown
G.E. Job No, 11415
Dear Randy:
Pursuant to your request regardi.ng'the above captioned project,
and per our phone conversation on September 9, 1993, we submit
the following:
At rear of the garage, apply a Simpson HD5A holdown with a 3/4"
diameter Hilti""HVA" bolt in lieu of the missing holdown strap.
For more information see the attached detail "A".
Note: ?lease verify the above with the building department prior
to construction.
If you have any questions, please do not hesitate to contact this
office.
Sincerely,
GOWIS ENG EERING
00 Nicholas A. Gouvis �pf5SS/p �a7m
President p V.p,S A �'�! Asso
NAG:RF: jf
attachment
0 No, C 12360 �+
11415253.FFL w
a N,�
Exp, 3/31/97
s�rF CIV 1-
OF CAti\
e Engineer
• i
56E P- 1 0- 9 3 F'R I 1 5 1 4 G O U V I S' E N G I NEER I N G' R. S
GOUVIS ENGINEERING J-N.C"I\y\Z-
Dat. �• 10 q'�
1. 44 POST, U.N.O.
I SIMPSONHOA
p
3. HILTI HVA ANCHOR j +
4. HS PER SIMPSON REQUIREMENTS
NOTES:
ALL BOLTS TO CONCRETE SHAD. BE. IAILTI
HVA ANCHORS VATH HEA RMN AND
INSTALLED -PER 1C80 $4016 AND MAIOUFAC—
TUREA'S RECOMMENDATIONS OR APPROVED
EQUAL '
i CONCRETE STRENGTH PC - 2000 psi MIN.
i ADEQUATE SIZE WASHER REQUIRED WHEN
ANCHOR DOLT SIZE IS SMALLER THAN
HOLE IN HOLDOWN.
CONTRACTOR SHALT. SPECIFY OVERALL
LENGTH OF ANCHOR
WHEN INSTALLNG HVA ANCHOR$ SPECIAL
INSPECTION IS REOUIRED.
ES. FT'G TO GARAGE MISSING F`jZ. �Z9
NON -MONOLITHIC POUR CAPACITY OF FIR = 3G50 #
14
is
r
BARRVA.BERKUS
A.I.A.
August 16, 1993
Harlan Lee & Associates
310 Washington boulevard
Marina Del Rey, CA 90292
Attn: Randy
Dear Randy:
lle7e7��1t
Per our phone conversation, I would like to clarify the location of the footing omission described in
the letter from Carl Schneider on August 12, 1993.
1. Due to the fact that the 3 -point bearing trusses have been redesigned as 2 -point
bearing trusses, the footing running the length of the house dividing the
LIVING/DINING areas
from the SLEEPING areas may be omitted. (not required)
If you have any further questions, please call.
Sincerely,
Barry A. Berkus, A.I.A.
Scott Branch
223 E. De La Guerra
Santa Barbara, CA 93101
805.'963-8901
Fax: 805/966-6846
` �1►iliiiJJ��
ti v •��
BARRY A. BERKUS
*e
�. LIC. #C7733
i
REN.•��@'�
0F
.,//,
��AL
1111111