Loading...
BRES2014-124978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: FOREMOST HOMES 70600 COUNTRY CLUB DR RANCHO MIRAGE, CA 0 4 Q"Krcu OMMUNITY DEVELOPMENT DEPARTMENT Va BUILDING PERMIT BRES2014-1249 52520 AVENIDA HERRERA 773294002 1,772 SF DWELLING/VB/RES-3/CLASS A-FR/13D $114,914.30 D-) L- �CgyOFL�QUINTA ' 00MMU% ELOPMEWDEPAWME41 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: 8 License No.: 926128 ate: -Contractor: Aghh�v #A.Av e C, &N C L.4- LA a k C. X10, OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for d permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her �wn employees, provided that the improvements are not intended or offered for sale. if, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. _ B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: 67 /e -r- ��/z VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/2/2015 Owner: FOREMOST HOMES 70600 COUNTRY CLUB DR RANCHO MIRAGE, CA 0 Contractor: DANTOR MARTINEZ CONSTRUCTION 81057 AVENIDA ROMERO INDIO, CA 92201 (760)775-4097 LIc. No.: 926128 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. — I have and will maintain workers' compensation insurance, as required by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: — — I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 4 1 —1 %- - - Applicant: WARNING: FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whos ' e benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 190 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. bate: Signature (Applicant or A�ent): 6 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY I AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $5.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $5.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT . PAID PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID ' PAID DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT. QTY •AMOUNT PAID PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 PAID BY - METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $0.00 PAID BY METHOD. RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT , , .' QTY AMOUNT PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY" AMOUNT PAID PAID DATE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 PAID BY METHOD RECEIPT # . CHECK # CLTD BY Total Paid forDIF - SINGLE FAMILY DWELLING $6,894.00 $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE SERVICES 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SERVICES PC 101-0000-42403 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forELECTRICAL: $36.26 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $24.66 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000 SF, PC 101-0000-42600 0 $10.16 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL FINISH GRADING PC 101-0000-42600 0 $143.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forGRADING: $143.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $36.26 $0.00 PAID BY - METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 _ $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $36.27 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $14.49 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for MECHANICAL: $188.54 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS 101-0000-20310 0 $537.00 $0.00 PAID BY METHOD RECEIPT # . CHECK # CLTD BY Total Paid for MULTI -SPECIES RESIDENTIAL- $537.00 $0.00 DESCRIPTION ACCOUNT QTY, AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $196.49 $196.49 12/15/14 PAID BY. METHOD RECEIPT # CHECK # CLTD BY DANTOR MARTINEZ CONST CHECK R3210 1188 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $315.30 $0.00 PAID BY METHOD RECEIPT # CHECK # . CLTD BY Total Paid forNEW CONSTRUCTION PERMIT: $511.79 $196.49 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,003.51 $1,003.51 12/15/14 PAID BY METHOD RECEIPT # CHECK # CLTD BY DANTOR MARTINEZ CONST CHECK R3210 1188 MFA Total Paid forNEW CONSTRUCTION PLAN CHECK: $1,003.51 $1,003.51 DESCRIPTION . ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT . QTY AMOUNT PAID PAID DATE BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BUILDING SEWER PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $145.08 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $145.08 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 $0.00 PAID BY METHOD RECEIPT # 'CHECK # CLTD BY DESCRIPTION 'ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD _ RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 301-0000-42600 0 $12.09 $0.00 PAID BY''�-'Y' ` :C ° ''x=+METHOD .'E:" ��#' `; RECEIPT# r CHECK# . CLTD BY Total Paid for PLUMBING FEES: $435.21 $0.00 DESCRIPTION,,' r ., { r} ACCOUNT ' ° `, •yQTY AMOUNT 'q µ . PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $14.94 $0.00 PAID BY METHOD RECEIPT # -; .: CHECK # CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $14.94 $0.00 - 'DESCRIPTION. ACCOUNT. QTY' "AMOUNT- t PAID PAID DATE SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $0.00 PAID BY ` = `'i METHOD ;L , RECEIPT # . . CHECK #' CLTD BY Total Paid forTUMF - RESIDENTIAL: $1,837.44 $0.00 TOTALS:• $1,200.00 3s� 4 Sep�I�IGJ ,J� r 3—IZI5 P.O. BOX 1504 APPLICATION ONLY (.,VO Building , ^ 78-495 CALLE TAMPICO Address ��. 111[[[/// [[[&Zak QUINTA, CALIFORNIA 92253 Owner Mailing Address lz� I Contractor (� Address City Zip I Tel. State Lic. City & Classif. I Lic. # Arch., Engr., Designer Address T . r3(o� ��y voI_ s Zip State Cf7 /_ /!tA Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031A Business and Prolewlans Code, Any City Or Counry winch requires 3 permit! 10 ConstruC� alter, ""prove, der"Olish, orropetr44structure, prlorfin its issuance also mqurms the applicant for such permit to life a signed valemerrt that he Is .ci t%ed putsuanf to the prOvisicns Of Me Contras• for's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Cade, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation otSectforl 7031.5 by any appi'l-N for a permit subjects the applicant to a civlf panaffy of not more than lve hundred dollars {$500). ❑ I, as owner or the property, or my employees with wages as their sole camponsation, wID do the work, and the structure is not Intended qr offered for sate. (Sec. 7044. Business slid Profes- sions Code: The contractor's bJcanse Law does nOt apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not Intended ar olfared forsale. If, however, tho bu"tdrng or improvement is sold within one year of completion, the owner -builder will have the burden df proving that he did not build or improve for the purpose of sale). 01, as owner of the property. am exclualvely mniraciing wilts licensed contraclors to construct the project. (Sec. 7044. Buslress and Professions Coda: The Contractor's License Law does not apply fd an owner of property who buifds or Imptdves thereon, and who contracts for such projecls with a contractor(s) licensed pursuant to the cfoCs License Law.) ❑ 1 am exempt under Sec. or this reason Hate r �:OE OR CO NSATION DECLARATION I hereby affffm that I t1pWa certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance a certified copy thereof. "Sec. 3800, Labor Cade.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work. for which this permit is issued, I shall not employ any person in any manner so as to became subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' Of. after waking Ihis Cerfllfcats of Exarrlption you sfrou!d become subject to the Workers' Ccmpensatidn provisions of the Labor Code, you must forthwith comply with such provisions ortfrls permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. cor* that I have read this appllcatlon and state that the above information Is correct. I agree to comply with all city and county ordinances and state taws relating to building corrstructfon, and hereby authorize representatives of this city to enter the above -mentioned property for inspection purposes. Signature of applicant Mailing Address — City, State, Zip Date BUILDING: TYPE CONST. OCC. GFIR A.P. Number 1+3 ~ A9 L2— Legal Description je4s-2-L- �S! Project Descriptions - Ft. _` size ,5 Slue JOJ New Add ❑ No. No. Dw. Stories Units Alter ❑ Repair ❑ Demolition ❑ I Estimated Valuation rI D ff)' 1 tCD PERMIT Plan Chk. Dep, Plan Chk. Bal. Const. Mech. Electrical S.M.I. Grading Driveway Enc. Infrastructure TOTAL I CONTACT INFORMATION NAME: PHONE: ZONE: BY:- Minimum Setback Distances: Front Setback from Center Rear Setback from Side Street Setbac r Side Setbac m Prop FINAL DATE NSPECTOF Issued by: Date Validated by: Line AMOUNT Line WHITE = BUILDING DEPARTMENT Validation: YELLOW = APPLICANT PINK = FINANCE Description: 1,772 SF DWELLING/VB/RES-3/CLASS A-FR/13D STAFF NAME ACTION DATE Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: APPROVED Applied: 12/15/2014 MFA FAMILY DETACHED 3/19/2015 Approved: 3/5/2015 JFU Parcel No: 773294002 Site Address: 52520 AVENIDA HERRERA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 151 Lot: 22 Issued: UNIT 16 REMAINING ITEM NECESSARY FOR ISSUANCE. Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $114,914.30 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 FOR ISSUANCE HAVE BEEN RECIEVED, PERMIT IS READY TO Details: 1,772 SF DWELLING - VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2013 CALIFORNIA BUILDING CODES. ADDITIONAL SITES CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES - E-MAIL AJ ORTEGA 3/19/2015 3/19/2015 EMAILED MR FORTSON SCHOOL FEE LETTER, THIS IS THE LAST REMAINING ITEM NECESSARY FOR ISSUANCE. EMAILED MR FORTSON ALL REMAINING ITEM NECESSARY E-MAIL AJ ORTEGA 3/23/2015 3/23/2015 FOR ISSUANCE HAVE BEEN RECIEVED, PERMIT IS READY TO ISSUE TO CONTRACTOR. NOTE ANGELICA ZARCO 3/20/2015 3/20/2015 RECEIVED SCHOOL FEE CERTIFICATION LETTER FROM SCHOOL DISTRICT. NOTE KAY HENSEL 3/2/2015 3/2/2015 PLANS ACTUALLY RESUBMITTED ON 2/27/2015, BUT NOT PROCESSED UNTIL 3/2/2015 PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 2/13/2015 - 2/13/2015 STRUC APPROVABLE - PROCESSED BACK IN 2/13/2015 RECEIVED Printed: Thursday, April 02, 2015 9:52:18 AM 1 of 7 CR V SYSTEMS PLAN CHECK COMMENTS FROM CONSULTANT PHILIP JUAREZ 1/6/2015 1/6/2015 PLAN CHECK COMMENTS RECIEVED FROM YOUNG ENG. 1-05- 2015 NOT APPROVABLE. RECEIVED PLAN CHECK PICKED UP AJ ORTEGA 1/8/2015 1/8/2015 PLANS, CALCULATIONS AND COMMENTS PICKEDUP BY DANNY MARTINEZ. PLAN CHECK PICKED UP MARY FASANO 2/17/2015 2/17/2015 APPLICANT PICKED UP PLANS FOR REVISIONS PLAN CHECK SUBMITTAL KAY HENSEL 12/15/2014 12/15/2014 PLANS RECEIVED BY MF AT BUILDING COUNTER RECEIVED RESUBMITTAL STEPHANIE KHATAMI 1/28/2015 1/28/2015 SENT TO PLAN CHECK KAY HENSEL 12/15/2014 12/15/2014 STRUC TO YOUNG - DUE 1/5/15 CONSULTANT LEFT MESSAGES W/ FOREMOST HOMES AT (760) 537-1502 AND ESCOBAR DESIGNS AT (760) 289-9221 NOTIFYING THEM TELEPHONE CALL JAKE FUSON 1/7/2015 1/7/2015 PLAN REVIEW WAS COMPLETE AND REVISIONS WERE REQUIRED. NOTIFIED DANTOR MARTINEZ CONSTRUCTION AT (760) 984- TELEPHONE CALL JAKE FUSON 2/17/2015 2/17/2015 0091 THAT PLANAEVIEW WAS COMPLETE AND REVISIONS REQUIRED. TELEPHONED ESCOBAR DESIGNS THAT PLANS WERE TELEPHONE CALL JAKE FUSON 3/5/2015 3/5/2015 APPROVED. PENDING DOCUMENTS:�GRANT DEED AND SCHOOL FEES. CONDITIONS CONTACTS NAME TYPE. - NAME ADDRESSI CITY STATE ZIP ... PHONE FAX EMAIL APPLICANT FOREMOST HOMES 70600 COUNTRY CLUB RANCHO CA 0 DR MIRAGE CONTRACTOR DANTOR MARTINEZ CONSTRUCTION 81057 AVENIDA INDIO CA 92201 ROMERO OWNER FOREMOST HOMES 70600 COUNTRY CLUB RANCHO CA 0 DR MIRAGE Printed: Thursday, April 02, 2015 9:52:18 AM 2 of 7 El Y IJ E✓ SYSTEMS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT a PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $5.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $5.00 $0.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 DIF - COMMUNITY 254-0000-43200 0 $0.00 CENTERS .$129.00 DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 DIF - PARK 256-0000-43200 0 $40.00 $0.00 MAINTENANCE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 DIF - STREET 255-0000-432000 $116.00 $0.00 MAINTENANCE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 Total Paid forDIF - SINGLE FAMILY DWELLING: $6,894.00 $0.00 SERVICES 101-0000-42403 0 $24.17 $0.00 SERVICES PC 101-0000-42403 0 $12.09 $0.00 Total Paid for ELECTRICAL: $36.26 $0.00 RESIDENTIAL, EA 101-0000-42403 0 $24.66 $0.00 ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $10.16 $0.00 ADDITION 1,000SF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 1,000SF RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,000SF, PC Total Paid forELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 Printed: Thursday, April 02, 2015 9:52:18 AM 3 of 7 =SYSTEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY RESIDENTIAL FINISH 101-0000-42600 0 $143.00 $0.00 GRADING PC Total Paid forGRADING: $143.00 $0.00 CONDENSER/COMPRES 101-0000-42402 0 $36.26 $0.00 SOR CONDENSER/COMPRES 101-0000-42600 0 $24.17 $0.00 SOR PC EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 FURNACE 101-0000-42402 0 $36.26 $0.00 FURNACE PC 101-0000-42600 0 $24.17 $0.00 VENT FAN 101-0000-42402 0 $36.27 $0.00 VENT FAN PC 101-0000-42600 0 $14.49 $0.00 Total Paid forMECHANICAL: $188.54 $0.00 MULTI -SPECIES RESIDENTIAL 8.1-14 101-0000-20310 0 $537.00 $0.00 UNITS Total Paid forMULTI-SPECIES RESIDENTIAL- $537.00 $0.00 NEW CONSTRUCTION 101-0000-42400 0 $196.49 $196.49 12/15/14 R3210 1188 CHECK DANTOR MARTINEZ MFA PERMIT CONST NEW CONSTRUCTION 101-0000-42400 0 $315.30 $0.00 PERMIT Total Paid forNEW CONSTRUCTION PERMIT: $511.79 $196.49 NEW CONSTRUCTION 101-0000-426000 $1,003.51 $1,003.51 12/15/14 R3210 1188 CHECK DANTOR MARTINEZ MFA PLAN CHECK CONST Total Paid forNEW CONSTRUCTION PLAN CHECK: $1,003.51 $1,003.51 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $0.00 Printed: Thursday, April 02, 2015 9:52:18 AM 4 of 7 CB?SYSTEMS INSPECTIONS -SEQID INSPE_ CTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT_ REMARKS NOTES DATE DATE - FINAL** Printed: Thursday, April 02, 2015 9:52:18 AM 5 of 7 CR�SYSTEMS CL • DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $0.00 BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 BUILDING SEWER PC 101-0000-42600 0 $12.09 .$0.00 FIXTURE/TRAP 101-0000-42401 0 $145.08 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $145.08 $0.00 GAS SYSTEM, 5+ 101-0000-42401 0 $36.26 $0.00 ' OUTLETS GAS SYSTEM, 5+ 101-0000-42600 0 $24.17 $0.00 OUTLETS PC WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 WATER HEATER/VENT 101-0000-42600 0 $7.25 $0.00 PC WATER SYSTEM 101-0000-42401 0 $12.09 $0.00 INST/ALT/REP WATER SYSTEM 101-0000-42600 0 $12.09 $0.00 INST/ALT/REP PC Total Paid for PLUMBING FEES: $435.21 $0.00 SMI - RESIDENTIAL 101-0000-20308 1 -0 $14.94 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMt $14.94 $0.00 SINGLE FAMILY 224-0000-203200 $1,837.44 $0.00 DETACHED Total Paid forTUMF - RESIDENTIAL: $1,837.44 $0.00 TOTALS:$1,200.00 INSPECTIONS -SEQID INSPE_ CTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT_ REMARKS NOTES DATE DATE - FINAL** Printed: Thursday, April 02, 2015 9:52:18 AM 5 of 7 CR�SYSTEMS BOND INFORMATION Printed: Thursday, April 02, 2015 9:52:18 AM 6 of 7 RSY57EM5 PARENT .O REVIEW.TYPE REVIEWER SENT DATE` DUE DATE RETURNED REVIEWS STATUS REMARKS NOTES DATE NON-STRUCTURAL JAKE FUSON 12/15/2014 1/5/2015 12/23/2014 REVISIONS REQUIRED CORRECTIONS SEE ATTACHED REVIEW. PLEASE BE REMINDED OF THE FOLLOWING REQUIREMENTS: LANDSCAPING. ALL FRONT AND EXTERIOR SIDE YARDS SHALL BE LANDSCAPED TO PROPERTY PLANNING JAY WUU 12/15/2014 1/5/2015 12/18/2014 COMPLETED COVE CHECK LINE; THE LANDSCAPING SHALL INCLUDE TREES, SHRUBS AND GROUND COVER OF SUFFICIENT SIZE, SPACING AND VARIETY TO CREATE AN ATTRACTIVE AND UNIFYING APPEARANCE. STRUCTURAL KATHRYN 12/15/2014 1/5/2015 12/15/2014 REVISIONS REQUIRED CORRECTIONS STRUC TO YOUNG, DUE 1/5/15. SAMUELS FIRE JACQUELINE 1/26/2015 2/9/2015 2/4/2015 APPROVED - GARCIA CONDITIONS NON-STRUCTURAL JAKE FUSON 1/29/2015 2/12/2015 2/3/2015 REVISIONS REQUIRED CORRECTIONS SEE ATTACHED SECOND PLAN CHECK CORRECTIONS YOUNG 1/29/2015 2/12/2015 2/12/2015 APPROVED APPROVED STRUCTURAL ENGINEERING NON-STRUCTURAL JAKE FUSON 2/27/2015 3/13/2015 3/5/2015 APPROVED APPROVED 1ST PW GREEN AMY YU 2/27/2015 3/13/2015 3/4/2015 INCOMPLETE RETURNED GREEN SHEET TO STEPHANIE FOR THE SHEET APPLICANT'S SIGNATURES 2ND PW GREEN AMY YU 3/9/2015 3/16/2015 3/9/2015 READY FOR APPROVAL PM -10 ONLY REVIEWED PM -10 ONLY SHEET BOND INFORMATION Printed: Thursday, April 02, 2015 9:52:18 AM 6 of 7 RSY57EM5 Printed: Thursday, April 02, 2015 9:52:18 AM 7 of 7 CR SYSTEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ' ETRAKIT ENABLED BRES2014-1249 - DOC 3/19/2015 AJ ORTEGA SCHOOL FEE SCHOOL FEE 0 CERTIFICATION CERTIFICATION.pdf CSLB LICENSE BRES2014-1249 - CSLB DOC 3/19/2015 AJ ORTEGA INFORMATION LICENSE INFORMATION 0 (WORKERS COMP (WORKERS COMP VERIFICATION) VERIFICATION).pdf BRES2014-1249 - SCHOOL FEE DOC 3/23/2015 AJ ORTEGA CERTIFICATION OF SCHOOL FEE 0 CERTIFICATION OF COMPLAINCE COMPLAINCE.pdf DOC 12/23/2014 JAKEFUSON NON-STRUCTURAL- NON-STRUCTURAL- 0 FIRST REVIEW FIRST REVIEW.docx.pdf DOC 2/3/2015 JAKE.FUSON NON-STRCUTURAL- NON-STRCUTURAL- 0 2ND REVIEW 2ND REVIEW.pdf LAQ-I5-RS-041 Lot 22 LAQ-I5-RS-041 Lot 22 DOC 2/4/2015 JACQUELINE GARCIA 52520 Avenida 52520 Avenida 0 Herrera.docx Herrera.docx 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 1/29/2015 STEPHANIE KHATAMI CORRECTION LIST AND CORRECTION LIST AND 0 COMMENTS BRES2014- COMMENTS BRES2014- 1249.pdf 1249.pdf Printed: Thursday, April 02, 2015 9:52:18 AM 7 of 7 CR SYSTEMS DESCRIPTION • QTY 1 •' �^S.-X"f'4 �il�gN Y. - d f - xi f^"" - ' y tirt-u A7 .. F•f 1r7.' `1 .L,i i Y �'_ PermItTRAK "`�1n:r.�r s "' � n.l...-,w..�«ze'.va.. U.�.•sa. .i: _G „d �`"�. :-^G.�w: ,ar t�'1w✓a.:++% .Af � �'e...,_Ic`.:ia�it�s;'�e�e i -•'i .c,u3,«.-.., St. �'%-x..r4.-,:C. ..fie ..w: . PAID $10,634!40 4� � hBRES2014 ddcrre.,�s;t c 2 s �AV.•E�NtID.,2r. ersµkx yj� 'i•r h 6sAA;34.40- ^ i r ',NEW CONSTRUCTION PERMIT t j; v" f"x i s'M {�,s 's , + $315.30 NEW CONSTRUCTION PERMIT 101-0000-42400 0 $315.30 ,.' "PLUMBING FEES �y;, ', f:., t��r+,s f t=f ....rj._.}' " . � ..� . $435.21 r, BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 BACKFLOW DEVICE 101-0000-42401 0 $12.09 BUILDING SEWER PC 101-0000-42600 0 $12.09 BUILDING SEWER 101-0000-42401 0 $12.09 FIXTURE/TRAP PC 101-0000-42600 0 $145.08 FIXTURE/TRAP 101-0000-42401 0 • $145.08 GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 WATER HEATER/VENT PC 101-0000-42600 0 $7.25 WATER HEATER/VENT 101-0000-42401 0 $12.09 WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 WATER SYSTEM INST/ALT/REP 101-0000-42401 1 0 $12.09 MOTION INSTRUMENTAY=r - 14.94TONWi SMI -RESIDENTIAL 101-0000-20308 0 $14.94 TUMF`-`RESIDENTIAL; Dw• r3 ry, �. x2r rk'i6 r>hiJ, ry ac rt ;G, , { ry. '.'.jr..F,• $1,837.44' SINGLE FAMILY DETACHED 224-0000-20320 TOTAL' 1 0 $10,634.40 $1,837.44 Date Paid: Thursday, April 02, 2015 Paid By: FOREMOST HOMES - Cashier: PJU Pay Method: CHECK 4516 Printed: Thursday, April 02, 2015 10:07 AM 2 of 2 CVCTFAAC DESCRIPTION ACCOUNT • PAID -_ei• ..sx 4Y. M•V.,'t+t $` i" ( PerrnitTRAK: O !h . $1U,634 40 _ w.l?..•e�rxwV{'_•. ,<45:•.b�: ,ai.}'.tr9i. •'.4'�.::+• F.�.' � .�'.> %'yµ4 1 a .' •$ ,. ' RES201r4 1249 Address 52520 AUENIDA`HERRERArxApn 77329�4Q02 �i` _634;-4d::. - :BUILDING STANDARDS ADININISTRATION.;BSA $5 ;00 BSAS SB 1473 FEE 101-0000-20306 0 $5.00 a' .DIF SINGLE _FAMILY DWELLING DIF - CIVIC CENTER 252-0000-43200 0 $942.QO DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DIF - LIBRARIES 253-0000-43200 0 $344.00 DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DIF- PARKS/REC 251-0000-43200 0 $2,048.00' DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 a ,,ELECTRICAL$36.26° SERVICES PC 101-0000-42403 0 $12.09 SERVICES 101-0000-42403 0 $24.17 ELECT NE RICAL W CONSTRUCTION= r _ $227J,1.,' RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0. $24.66 RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $10.16 RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 , GRADING; RESIDENTIAL FINISH GRADING PC 101-0000-42600 0 $143.00 MECHANICAL CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 CON DENSER/COMPRESSOR 101-0000-42402 0 $36.26 EXHAUST HOOD PC 101-0000-42600 0 $4.83 EXHAUST HOOD 101-0000-42402 0• $12.09 FURNACE .PC 101-0000-42600 0 $24.17 FURNACE 101-0000-42402 0 $36.26 VENT FAN PC 101-0000-42600 0 $14.49 VENT FAN 101-0000-42402 0 $36.27 „ MULTI SPECIES RESIDENTIQI s • ti MULTI-SPECIES RESIDENTIAL 8.1-14 UNITS 101-0000-20310 0 $537.00 Date Paid: Thursday, April 02, 2015 Paid By: FOREMOST HOMES Cashier: PJU Pay Method: CHECK 4516 Printed: Thursday, April 02, 2015 10:07 AM 1 of 2 CYCTFMf P.O. BOX 1504 APPLICATION ONLY Building �}UE�1�. 4 {-1Eae;Q B 495 CALLS TAMPICO Address C5(::2 a -Sao UINTA, CALIFORNIA 92253 Mailing -10 (PW Address coon,knA UV6 9r. Zip Tel. �, 2 n l �b i. zip 1 22,D) Tel MoD BUILDING: TYPE CONST. OCC. G RA 3 (5I 1e'F4ro A.P. Number 3 ��1 p �"l 1502 Legal Description VI 2Z 52O 520 Aveh ict� 'effe a L, 'v Project Description tw 5 f t State Lic.n UP 2A City & Classif. `1 Lic. # Arch., Engr., Designer Address Tel. 3gZ1 t�aGn-2O Cv2 City Zip �, j State ( (� q2 u II Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Divisi 3 of the Busin ss and Professions Code, and my license is in full force and effect. rt�yi ` SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and. Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). O 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Sq. Ft. Size No. No. Dw. Stories Units New4l Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation f OM W PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road ¢ BERM U DADUNES V) RANCHO MIRAGE b Date 3/20/15 La Quinta, CA 92253 � INDIAN WELLS No. 31745 �cy� P LM DESEFrr L QUINTA y (760) 771-8515 Z�1INDDIO y�� Owner Foremost Homes, LLC APN # 773-294-0 n Q Address 76600 Country Club Dr Jurisdiction La Quint City Rncho Mirage Zip Permit # MAY �j O /�fr Tract # No. of Units 1 ((�� i Type $0.16 Rate Increase since May'14 coMMUNiir �� pp QUINTA MFNTpfP Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 _52250 1 Avenida Herrera 1585 Unit 6 Unit 2 5.25ZO Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments 11/22/13, Certs #31888 & 31889, paid for 1,585 sq ft. New total = 1,772 sq ft At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.16 X 1,585 S.F. or $253.60 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC - California Bank & Trust - James Fortson Bank Name/Recipient of Certificate By Dr. Gary Rutherford Superintendent Fee collected /exemptSd by Signature Ivrey Check No. 467537 Telephone Funding Residential Payment Recd I$O.OF 0 -771 l -- $253.60 ,lover/UkdeP NOTICE: Pursuant to Government Code Section 66020(d)(1), this serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Date 3/20/15 No. 31746 Owner Foremost Homes, LLC Address 76600 Country Club Dr City Rncho Mirage Zip Tract # Type New Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 Lot # No. Street Unit 1 52520 Avenida Herrera Unit 2 Unit 3 Unit 4 Unit 5 APN # Jurisdiction Permit # No. of Units S.F. Lot # No. 187 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Comments 11 /22/13 , Cert #31888, paid for 1,585 sq ft. New total = 1,772 sq ft z �o BERMUDA DUNES r RANCHO MIRAGE C1 INDIAN WELLS PALM DESERT INDDIO � T 773-294-002 La Quinta 1 Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.36 X 187 S.F. or $628.32 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC -California Bank & Trust - James Fortson BY Dr. Gary Rutherford Superintendent Check No. 467537 Bank Name/Recipient of Certificate Telephone Funding Residential w Fee collected /exempt by S aro Mc rey Payment Recd $628.32 `fiver/Uneiar n Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this ill s e to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on ' h the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7012 FAX (760) 777-7011 CERTIFICATION OF BUILDING AREA STREET ADDRESS OF JOB:_ 52-520 AVENIDA HERRERA1 'APN: 773 —..294 — 002 DESCRIPTION OF WORK: SINGLE FAMILY DWELLING, SQUARE FOOTAGE: 1,772 OWNER'S NAME: FOREMOST- HOMES j 'NOTE: OWNER HAS ELECTED TO WITHDRAW PREVIOUS APPLICATION FOR CONSTRUCTION OF 1,585SF DWELLING, FEES PREVIOUSLY PAID 11/22/2013, NUMBER 31889 — THIS CERTIFICATION OF BUILDING AREA IS BEING ISSUED PURSUANT TO CITY OF LA QUINTA POLICY, ANY CREDIT OF FEES SHALL BE DETERMINED AT THE DISTRICTS. DISCRETION"" For questions regarding this letter, please call: City of La Quinta Permit Center (760) 777-7012 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 CITY OF LA QUINTA BUILDING & SAFEW DEPT, APPROVED FOA CONSTRWWN Please note: This letter verifies conditioned square footage. Please call your School District to verify school fees, requirement for cashier's check or money order and hours of operation. YOUNG 171E - �z ENGINEERING q p s e a v M t V-1104 M Letter of Transmittal To: City of La Quinta Today's Date: 2-11-15 78-495 Calle Tampico City Due Date: '2-11-15 La Quinta, CA 92253 Project Address: 52520 Avenida Herrera Attn: Kay Plan Check #: BRES 2014-1249 Submittal: ❑ 1St ❑ 4th ® 2nd ❑ 5th ❑ 3rd ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes: # Of Descriptions: Copies: Copies: ❑ Structural Plans ® 1 Revised Structural Plans ® 1 Structural Calculations ® 1 Revised Struct. Calcs ® 1 Truss Calculations FloorEl Revised Truss and Roof ❑ Soils Report ❑ Revised Soils Report ® 2 Structural Comment List/ ❑ Approved Structural Plans Responses ® 1 Redlined Structural Plans ❑ Approved Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable If you have any questions, please call. Time = 1.5 HR This Material Sent for: ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: Kathryn Samuels Palm Desert Office: ® (760) 772-5107 Other: ❑ FEB 12 2015 CITY OF &A QUINTA COMMUNITY bEVELOPMENT �t M BUILDING ENERGY ANAL PROJECT: FOREMOST HOMES INC. Plan 1772 GR Lot 22 Avenida Herrera - A. P.N.: 773-294-002 La Quinta, Ca 92253 Project Designer: ESCOBAR DESIGNS 43927 Pacific Ave. Indio, Ca 92201 760.289.9221 Report Prepared by: Santiago Lopez-Ocampo Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 Job Number: LQ 100514 L22 Date: 12/5/2014 C6TY OF LA CUINTA BUILDING & SAFETY DEPT. APpRO FOR CONSTRUCTION , � 1 CITY OF LA QuiNTA C®MPRUN TY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed;by EnergySoft, LLC — www.energysoft.com. Ene Pro 6.3 by EnergySoft User Number. 5732 ID: LQ 100514 L22 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 11 HVAC System Heating and Cooling Loads Summary 14 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION DATE BY EnergyPro 6.3 by EnergySoft Job Number: ID: LQ 100514 L22 User Number: 5732 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:17, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Right [lot 22 Avenida Herrera] 120514.xm1 CFIR--PRF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name FOREMOST HOMES INC. :,... 02 Calculation Description Title 24 Analysis 03 This bulldln incor orates one`or more"$ecial Features shown' blow 9 p ........ P 03 Project Location Lot 22 Avenida Herrera - A.P.N.: 773-294-002 04 A City La Quinta 06 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2)1772 15 Number of Zones 1 16 Slab Area (FT2)1772 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT 2) N/A 21 Glazing Percentage (%) 10.5% COMPLIANCE RESULTS 01 Building Complies with ComputerFPerformance .: :,... 02 This building Incorporates features thatreiaulre field testing and/or;veiltication by a certified,HEF;S rater under'the supervision of a CEC-approved HERS provider. _a te _ - ., W. _.. ;. � �.:. � � .<._ «. 03 This bulldln incor orates one`or more"$ecial Features shown' blow 9 p ........ P ENERGY USE SUMMARY 04 05 06 07 08 Energy Use 0 (kTDV/ft) DDesign 4 a3 Standard Proposed Design Compliance Margin Percent Improvement Space Heating m 0.34 0.46 -0.12 -35.3% Space Cooling 95.43 97.46 -2.03 -2.1% IAQ Ventilation C7 1.20 1.20 0.00 0.0% Water Heating z 13.63 11.33 2.30 16.9% Photovoltaic Offse 'CO —{Cn -- 0.00 0.00 -- Compliance Energy T i I C 110.60 110.45 0.15 0.1% - -iC z®M� Registration Number: 214-No153185A-000000000-0000 Registration Date/Time: 2015-01-22 13:16:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-12-05 10:19:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R=PRF-01 Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:17, Fri, Dec 05, 2014 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Right [lot 22 Avenida Herrera) 120514.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None – ENERGY DESIGN RATING"xh in. E �h: This is the sum of the annual TDV energy,consumphon fo energy use components included the performance compliance approach fog the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not"regulated byTitle 24 F'art.6'(such as domestic aPpl,iances.and.consumerelectronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy'f)esigrrRaUng Margin Percent Improvement Total Energy (kTDVlf2)" 160.69 160.64 .:, 0.15 0.1% 0 includes calculated Appliances and M@j ellaneous Engpy Js ( MEU) m _ C -, BUILDING - FEATURES INFORMA I N 01 C7DV Z O 03 04 05 06 07 Project Name Qo nditio for r ) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems FOREMOST HOMES INC. 7 D 1 3 1 0 1 ZONE INFORMATION C 01 03 04 06 06 07 Zone Name -0 —i Zone Type '� D HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House HVAC Systeml 1772 9 DHW Sys 1 Registration Number: 214-No153185A-000000000-0000 Registration Date/Time: 2015-01-22 13:16:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:19:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:17, Fri, Dec 05, 2014 Page 3 of 8 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Right [lot 22 Avenida Herrera] 120514.xml OPAQUE SURFACES 01 02 03 04 06 06 07 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft) Tilt(deg) Ri/S 44.66'x 9' Whole House R-15 Wall 180 Right 402 56 90 Re/E 41'x 9 Whole House R-15 Wall 90 Back 369 96 90 Le/N 44.66'x 9' Whole House R-15 Wall 0 Left 402 9.2 90 Fr/W 41' x 9' Whole House R-15 Wall 270 Front 369 25 90 Roof Whole House R-38 Roof Attic w/Radiant 1 25.0 400 0.23 Insect Screen (default) Roof 2 Whole House R-38 Roof Attic w/Radiant /E 41'x 9' (Back -90) 564 1 48.0 Roof 3 Whole House R-38 Roof Attic w/Radiant 60802 Win 564 S?o /E 41'x 9' (Back -90) Roof 4 Whole House R-38 Roof Attic w/Radiant I 0.23 244 1616 ATTIC 01 02 03 04 06 06 07 Name 1 Construction , x £ Roof Rise ' z : " ? RoofpRef 86rice. Roof Emittance Radiant Barrier Cool Roof Attic' Attic Roof°C ons g4 03 "� x ; 0 1 " - 0.85 Yes No WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Ty u a e (Orientation -Azimuth) Height Width(ft) (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading 2030 Win ow!; 03 i/ 44.66'x 9' (Right -180) - -- 1 6.0 0.30 0.23 Insect Screen (default) 5050 Win o lil -11 - i/ 44.66' x 9' (Right -180) - -- 1 25.0 0.30 0.23 Insect Screen (default) 50502 Win i/ 44.66'x 9' (Right -180) - -- 1 25.0 0.30 0.23 Insect Screen (default) 6080 Win n /E 41'x 9' (Back -90) - -- 1 48.0 0.28 0.23 Insect Screen (default) 60802 Win Z S?o /E 41'x 9' (Back -90) - -- 1 48.0 0.28 0.23 Insect Screen (default) 1616 -I'JJ L /N 44.66' x 9' (Left -0) - -- 1 2.3 0.30 0.23 Insect Screen (default) 16162 C ffl L /N 44.66'x 9'(Left-0) - -- 1 2.3 0.30 0.23 Insect Screen (default) 16163 In7� � CL /N 44.66'x 9'(Left-0) - -- 1 2.3 0.30 0.23 Insect Screen (default) 16164 O C)C L /N 44.66' x 9' (Left -0) - -- 1 2.3 0.30 0.23 Insect Screen (default) 50503 -0 r W 41' x 9' (Front -270) - -- 1 25.0 0.30 0.23 Insect Screen (default) Registration Number: 214-NO153185A-000000000-0000 Registration Date/Time: 2015-01-22 13:16:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-12-05 10:19:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR=PRF-01 Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:17, Fri, Dec 05, 2014 Page 4 of 8 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Right [lot 22 Avenida Herrera] 120514.xml DOORS 01 02 03 01 02 03 04 Name Side of Building Area (W) U -factor 3080 Fr/W 41' x 9' 24.0 0.50 3068 Fr/W 41' x 9' 20.0 0.50 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 06 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers 07 Name Zone 2x4 Top Chord of Area (ft2) Cavity/ Frame: no insul. /2x4 Top Chrd Carpeted Fraction Heated Exposed Roof Truss @ 24 in. Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing: Light Roof (Asphalt Shingle) 710 0.1 None 0.8 No • Inside Finish: Gypsum Board • Cavity/Frame: R -15/2x4 R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 Exterior Finish: Wood Siding(sheathing/decking • Inside Finish: Gypsum Board M x Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic w/Radiant Ceilings (below attic) £ rft6d Framed CeIIIrIg� 2x4 @ 24 In O C' Ft 38 •Over Floor Joists: R-28.9 insul. SLAB FLOORS k< - 4 A Reg 01 02 ' <:':: 03 04 :.. 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Exposed Whole House 1062 0.1 None 0.8 No Covered pWhole House 710 0.1 None 0.8 No I --I ;;;-- =-- I BUILDING ENVELOPE - HERS VERIFICATI r= 01 — 02 03 04 Quality Insulation Installation (QII) 1 ation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required -- WATER HEATING SYSTEMS C (TI 01 d4 M 03 04 05 06 Name Syste a Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHOV Pipe Insulation, All Lines DHW Heater 1 1 .0% Registration Number: 214-NO153185A-000000000-0000 Registration Date/Time: 2015-01-22 13:16:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:19:37 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:17, Fri, Dec 05, 2014 Page 5 of 8 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Right (lot 22 Avenida Herrera) 120514.xml WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.65 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 06 07 Heating System Cooling System Distribution Efficiency Floor Area Name System Type. NameDucted Name Ducted System Fan System Served Compressor HERS Verification 01, , ng Split i�n' 11 95 15 Systeml g Other Heat/ Heating ent F ComponentFl Yes Air Distribution 1772 HVAC 1 -hers -cool Compo 1 Yesj Cooking s System 1 d �. . .b .. o,> HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 11 D CntrlFurnace - Fuel -fired central furnace 92.5 AFUE M HVAC - COOLING SYSTEMS Q r 01 02 U z 03 04 05 06 07 Q —� Efficiency Multi -speed Name ystem fpm EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirC ng Split i�n' 11 95 15 No No Cooling Component syste — rr ill 1 -hers -cool z®MID � �> Registration Number: 214-N0153185A-000000000-0000 Registration Date/Time: 2015-01-22 13:16:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-12-05 10:19:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR'-PRF-01 Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:17, Fri, Dec 05, 2014 Page 6 of 8 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Right [lot 22 Avenida Herrera) 120514.xml HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 f> , -n Verified Duct Design Low -leakage Supply Duct IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Specified Lower 8 Attic Attic None Air Distribution 6 0 Not Required Leakage Target Not Required Required 1 -hers -dist ' ¢� System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 z Qo Required 0.58 Duct Leakage, f> , -n Verified Duct Design Low -leakage IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 47.72 Name Verification Duct Leakage Target (°!°) 4 Verlfied Duct Location Return Supply Air Handler Air Distribution System Required 6 0 Not Required Not Required Not Required Required 1 -hers -dist ' ¢� y HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan 1 W.. �W HVAC FAN SYSTEMS - HERS VERIFICAT -� 01 02 03 Name C7 VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan z Qo Required 0.58 1 'm — A-.� W L 1 IAQ (Indoor Air Quality) FANS TI 01 1 03 04 05 06 Name IAC@Q z IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 47.72 0.25 Default 0 Required L' I Registration Number: 214-No153185A-000000000-0000 Registration Date/Time: 2015-01-22 13:16:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:19:37 Im CITY OF LA QUINTA BUILDING & SAFETY DEPT, APPROVED FOR CONSTRUCTION DATE BY O N C') N N O Lh O N rl Ln If It 0 N n Q O cc 7l u c O N N t O CL v w r Op ci 4 U. O F � r � d ui fa LL U Im CITY OF LA QUINTA BUILDING & SAFETY DEPT, APPROVED FOR CONSTRUCTION DATE BY O N C') N N O Lh O N rl Ln If It 0 N n Q O cc 7l u c O N N t O CL v w CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:17, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Right [lot 22 Avenida Herrera] 120514.xml CF1R-PRF-01 Page 8of8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Santiago Lopez-Ocampo Company: Signature Date: Santiago Lopez-Ocampo 2015-01-22 13:11:31 Address: CEAMERS Certification Identification (If applicable): P.O. Box 1018 NA City/State/Zip: Phone: La Quintal, CA 92247 760 485 8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system.deslgn features identified.on„this Certificate of Compliance are,consistent,with the information provided on other applicable compliance documents, worksheets, calculations, plans and Specifications subm tted to the enforcementagency forapproval with this building permit application. Responsible Designer Name: r F ` n 'y s6 Responsible Designer Signature x 11q .fi” '�'^t� A / f Ah ^;F -iWKW ���WV�YV Eduardo Escobar... ,_ Company: Date Signed.'. Escobar Design 2015-01-22 13:16:50 Address: License: 43-927 Pacific Ave. NA City/State/Zip: Phone: Indio, CA 92201 W 0 760-289-9221 Digitally signed by Ca10ERTS. This th ital sign r poi information. Z ® 0 '0 D to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the Registration Number: 214-NO153185A-000000000-0000 Registration Date/Time: 2015-01-22 13:16:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:19:37 MANDATORY MEkWRE� t . �`81UMMA". e 'd, ia ageii-1'6(3) MF' Si 666 AR Project Name Date FOREMOST HOMES INC. Plan .1772 GR, 121512014 NOTE: Low-rise residential building's siUbi6Ct`t6thdSta- le,*mp.� 6 6' 're' -rdle, of oppliob n. sures listed,' �p gp ..,mpp the compliance approach used. More stringent energ'y'm-'eiisiJ're's' isted on th. f C ' , orn "lianc - e (CF-1R,'CF-'1jR-AbD or I R -ALT Form) shall supersede the items marked with an asterisk (*) below, 7.0ip M4906 t� r,o'r' ed' pys, p V into the permit documents, and the applicable features shall be consid6i�ed by adl* pa" ie' as..minimu I m comp . on . 0 to, . t,per . form - e specifications whether they are shown elsewhere in t he documents or in I t . hi's surrim'a ubmit'all applicable'se6tion's 6,, tl�6 MF -1 R Form with plans.. Building E v616.0 '-M AM e 0 se § 1 10.6(a) 1: Doors and windows between conditione�d, and unicortditi :ned. afc6,,sc�re�:mahbfa�&u�6dtQ.Iimit.pir,loakape. §1 10.6(a)4: Fenestration products (exdeot'ii�ld�-fabnc6ted'�AfihdoW,.§) haVe'a l4bel listinig'" de*rtifio.d.U'-Fa6tpr,�,c,6riifi6d Solar Heat'Gain Coefficient (SHGC), and infiltration that mpets.the require s*6 10-1.111 '(a' §110.7: Exteri eather-st ns�; or doors and windows arew OeO; ailj6i�ts ano.'Opnetraiti6 ar6 C001 Red .1 d S�e:ail-6d. §1 10.8(a): Insulation specified or installed. at n:�61' 'indi, �'4��e a6d in ude , on CF -2R Form. meets Standards for. InsvIating M e §110.8(i): The thermal emittance and s6larr6fledtanceViilu6s'*'bftfi-'e,c6.of r66firf1g material meets the r6qui�briibnts of §110.8(i) when the installation of a Cool Roof is specified on the.CF-1R-F6rrn­ *§150.0(a): Minimum R-30 (R-19 for Alterations) insulation.in woo.d-fPme.ceiIing.'or equivalent U7factor. §1 50.0(b): Loose fill insulation shall conform W'th.,m6n6faqturer-s install�d d'�'§`i"g'n'la' Oeled"RJ aue. *§150.0(c): Minimum R-13 insulation in 2x4wood-frame� -19tn2 )oreqUiiy.1IenfU-fzicor. *§1 50.0(d): Minimum R-1 9 insulation in raised wood-frpMe floor or equiyaleint 1.1 -factor. i J §150.0ft Air retarding wrap is tested, labeled, and installed accprdi g to A,5TME16 7 . 7�-9 - 5(2'000)'-whenispecifi don ih"�tF21JR Form-, §1 50.0(g): Mandatory Vapor bapier installed t - JnClima e Zones 14 or 1.6 §150.0(1): Water absorption rate for slab edge iinsUlatidti.r�oteKAI alorie,with&Alaci . ng , s i , s aile r1hani 0. 3%.;w6t6r vapor pe . r . mpance I no"gre. rate is no greater than 2.Q permi/inch -and shall be protecte rdrbi�hysical,,�prA6'��'36'andUVlight'd6t�' rab go on.. qe §150.0(q) FenestratiohProdud6:-Per�6gVafi�on se0eii6ting"conditiondd space from*- Unconditibn'6d sp- - "'i ir'bLitdoof9 -,hall meet the"' requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must. have a maximy7i U-Ifactor of 0,58. 2. The weighted average U -factor of all fenestration, including sk9lig t pro Ucls, -shall not bxc ' 'til'' eed 0. 58. EXCEPTION to Section 150.0(q)l: Upto 10 square feetlof fenestration area'or.q..�.percpqj of the Conditioned FloorArea, whichever is greater, is exempt from the maxirrium V -fact rem6nt. §1 50.0(r) Solar Ready Buildings. Shall meet the. requiremiehiii"of Section"I'10 a blet 1h - b ca o e ui ingproject­­ Fireplaces, P6wrottvi Ga� A00 iakips and Gas LogUleai�ujr:bj�: ..7 niilre ope of 04" §1 50.0(e)IA: Masonry or factory -built fireplaces. have, a, c1psablem eital,dr,'�.glass qr.cqv�Tdrig the.e ni-n fireb6x*. ­.. §1 50.0(e)l B: Masonry or factory -built fireplac��ti6�i�.i*6brhbUttion'*biA�id6'6ir�int6ke,'zih'i'c'h I t I' ist six's &es inarea'an s a ea 'd i'� - i quare Jin .1 . - " d tight- ffin*_q'd vice.'. equipped with a with a readily accessible, operable, an fi "am p . 6r Ja - hd or'a c(imbustionilpir',d i6l,,dI6 g eifireli6k ikket, whe §150.0(e)2: Continuous burning pilot lights arid.the' U -se- df lndc��6irf& is vented *to - the outside of the.building, are.prohibited. 11. I ';i� ; Space Condifignin , Watee, HiRafing --6inid.Flumbing' Systek. , eaSpres: t T Q. r M §110.0-§110.3: HVACequ'i0mdht, Waterh6ateis.'showeirtidbids-, faucets andall other reeufaQ0Ah&Jt&&r,6ftPffi erg y Commission. A r-1 r-% r-1 f-% I §1 10.3(c)5: Water heating recirculation loops serving multiple diWling*urfits and High-Ri e'rdsid nK1cEc-0p`AA W­s%fnWkh6 air,rele3se valve, backflow prevention, pump isolation. valve., and recirculatipR+.Ioop connection' §110.5: Continuously burning pilot lights are prohibited f6i"nafufal g ais*:Jan;"-typ'e' cdbtral. Mqce§,..hic�lus6liold..c�6,6king appliances',' - (appliances with an electhcal supply voltage connection with pilot lights that consume' le BtLAr`aii*& , - "empt), and po'61'a 0 IS69%160 spa heaters. -T §1 50.0(h): Heating and/or cooling loads are calculated in accordance withASHRAE, 5MACNA or ACCA. §150.0(i): Heating systems are equipped with,thermostats; that.mept the setback. reqiurementsof Section 11.0.2 c). § 150.00)1 A: Storage gas water heaters irafiid wiih art E:nerg'y'Fpdt6i 66.,gir*eaterthai f6der.� inJm41.stdrid�rd6r6 odern"ally' wrapped with insulation having an installed thermal resistance o. R71, or greater. §150.00)lB: Unfired storage tbiriks',- such 6i�stordde''td6ks orbakkup­ tanks for s6lat water, -6atirig system,'or 6the�r indi cthot��teir -h re tanks have R-1 2 external insulation or R-1 6 internal insulation where the interrial insulation k -value is indicated on the exterior of the tank. 6.3 by EnergySoft.. User' Nurnb6k'5�3�? ID.-LQ10 5�44?2 page I! oi,14,1 MANDATORY MEASURIIES,SUMMAO., R I es id'entiaJ`­;,,,,., - '(Pag�-. 2 of 3) MF -1 R Project Name Date FOREMOST HOMES INC. Plan 1772 GR 1121512014 §150.00)2A: All domestic hot water *syttehi pioin-j'66hditidins listeid b616�, 4uhether buri4d'or unbUNed, musf be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold waterpipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimetef)'or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between . t6nks. v. Piping buried below grade. vi. All hot water pipes from the heating source tothe kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic h6atin4'sy6tems 6rhdt water systems �>15*psi, meets the requirements of Standards Table 120.3-A. §150.06)3A: Insulation is grotected from damage, including that due to.sunlight, moisture, equipment maintenance, and wind. §150.06)4: Solar water-hebtihg' systems,and/or collectors are, certified b y- the Solar Ratipo and Cettificati6ri Corp6ration. §1 50.0(m)l: All air-disthbutioh system -ducts and plen'Ump fri'sUled, are sealed an; irisqIated to meet the requirements of CM0. Sections 601, 602, 603, 604, 605 and Standard 6-.5; supply -'air and retum'-air ducts and. plenurns.-are ir�sulatecl to a niinimurn installed level of R-6 or enclosed entirely in conditioned space. Openings shall be.se al I ed wit . Kmastic, ta'6 oi other dOL-t-'cids p ure iystern that . meets the applicable requirements of UL 181, UL 181 A, oir UL 181 B oi�*aerosiol thatmeets the requir6merfts df.UL 72'3. If miasti c . or tape is used to seal openings greateir than 1/4 -inch, the combinatio . n.of masti c4rid efther'mb.sh or tape shall be. Used §150.0(m)l: Building cavities, support platformsifor arif'harldlqts, 90�.pleinums defined or'con strubted with materipiscither-thab sealed sheet metal, duct board or flexible duct shall hdb6 used for* conveying conditioned air. 8uildiri� ca'vities and su0port platforms may � contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductl 'ohs in the 6ross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and the.ircornponents.shall. n6t.be'.sealed with cloth back rubber adhesive duct tape's unless such tape is used in combination with masfic artd draw bar�ds. §150.0(m)7: Exhaust fan systems have bapkdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned sp6ce'haV6 either a- matic or reachly accestible, manually operated dampers. §1 50.0(m)9: Insulation shall be protected fr6mdamage, iriduding that due to sunlight, moisture equipment Toihteriance, and'.,wind. . , Cellular foam insulation shall be protected asabove or painted with a coating thai is waterretardant and provides sbielcring from s'o'lar radiation that can cause degradation of the material. §1 50.0(m)l 0: Flexible ducts cannot have porous innercores. §150.0(n)l: Systems using gas or propandWatdrM . aterg, Whether i�nk or on-dem -and, to seNeindividu , al dwelling units'shall include all the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the spac6 where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacitX of at least 20.0,000 Btu/hr. §1 50.0(o): All dwelling units shall ii-e6t the requirements of ANsi/ASHRAE Standard 62.2 Ve 6filati ' o"nAnd Acceptable Indoor Air.Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation requ'ieed in Section 4 of that Standard. Pool and Spa Heating Systems and t9dip Mient Meastires: §1 10.4(a): Any pool or spa hea rig §Vstem shall be'certified t6havd a thermal dfficiericy that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of'the heater; a permanent weatherp o a e or d-vifith-opeiating4n6tpictions- and shall not use electric resistance heating. or a pilot light. �1.1 ITY Or: I A ni imi-rA I §1 10.4(b)l: Any pool or spa heating equipment shall be installed with at least 36" of i p - , , , adra a r, d suction P I�JTTI and return lines, or built-up connections for future solar,heating. & SAFE DEPT §1 10.4(b)2: Outdoor pools or spas that ha�e a heat pump orgas heater.shall hav I e coVer.APPROV §1 10.4(b)3: Pools shall have directional inlets that 6deqbattily ini the po' via o I ie set or �. 91 -ter, ai id a tJrrf,"ctTJ!A8JA programmed to run only during off-peak.elec�tric demand periods. §150.0(p): Residential pool systems or equipmgnt �2�! t!Le.pump sizing, flowrote,jii Iter . s, and v64,requirements of §15 3.0(pj� Residential Lighting Measures: §150.0(k)l A: Installed lurninaifes'6hall be classified as high -efficacy or'low-efficacy for"c'omp'Iianc6 With Section 150.0(k) in ae;cordance with TABLE 150.0-A or TABLE 150.0-B, as, applicabl §150.0(k)lC: The wattage of per anen'tlyinsta*lledIUMiK6',re'*�'sh�31115686t6rm'.inedasi�)etifi6dby-§130.Q(c). §1 50.0(k)l D: Ballasts for fluorescent lamps rated 13,W.14s orgreater shall be electronic andshall have an output frequency <= 20.kHz. §150.0(k)lE: Permanently installed night lights and night'lightsinteigral to installed luminoiresor exhaust fans sb6ff.be iated.to consume , no more than five wafts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancX sensors. EnergyPro6.3byEnergySoft * Us&Nuinber'.5732" JDAQ 166514122 Pave 12 of 14 MANDATORY MEASUk8S SVMMAi��id MF_1 k ehfi�d_.­.., (Pag 3 of 3) Project Name Date FOREMOST HOMES INC. Plan 1772 GR 1121512014 §1 50.0(k)l F: Lighting integral to exhaust fans, in rooms other than kitchens,, shali.meet the.applicabl6 requirements of §150b(k). §150.0(k)2: All switching devices and controls shall meet the requirements of §150.%k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage'6f pdrmanently installed lighting in-,�itphiins ii�haU be high efficacy - EXCEPTION: Up to 50 wafts for dwelling units less than or equal to 2,500 ft' or 100 watts. for dwelling units larger than 2,500 f12 may be exempt from the 50 percent high efficacy requirement when all 'and lighting in the kitchen is controlled in accordance with the applicable provisions" in Sedtion� 150'0(k)2, is also controlled by vacancy sensors or climmers. §1 50.0(k)4: Permanently installed lighting that is internal to cabi;ets shall use no' more than 20 watts of poWer'oer linearfoot of illuminated cabinet. §1 50.0(k)5: Lighting installed in bathrooms stiall meet the following ileqUjr�eftients: A. A minimum of one high efficacy luminaire shall be installed in each bathlroo-ri-'a6d, B. All other lighting installed in eachbathroomshall be high effic-ppy or controlled by vacancy sensors. §1 50.0(k)6: Lighting installed ih'bttatdhed 6hd detached garages, laundry r6oms, and Utility ro6ms shall be high efficacy' luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas� other than in kitchens, bathrooms garages, laundry rooms, and Utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than fo.00 square feet located on a residential site. §1 50.0(k)8: Luminaires recessed:into insulated ceilindsshall be listed for Ze.ro-cliaran't6',i-h,sUliti6n Wntact* - (IC) �by Underwriters Laboratohes or other nationally recognized testing/rating laboratory;, ond.havo a1abel-that certifies the lurnihairels airtight with air I leakage less than 2.0 CFIVI at 75 Pascals when tested I in id6o�daride with ASTM E283,; and be sealed with 6 . g . asket or caulk . between the luminaire housing and ceiling. — idential building or other building" on' §150.0(k)9A: For single-family residential buildings, outdoor lighting perminently moun - t eid t& a - re s the same lot shall be high efficacy, or may be low efficacy if it meets all of the following re�uiremept$: i. Controlled by a manual ON and OFF switch that does not override to ON theautomatic actionsbi items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion s6rising'Junction' and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocont.rol; or b. Astronomical time dock not having an ovemde or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during da�ight 'hours; or c. Energy management control system which meets all of. the following requireme nts: At a minimum provides the functionality of an astronomical time 61cick in acc6rdance with Section 1 110�9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EIVICS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF duhng daylight hours. §150.0(k)9A: For low-rise multi -family residenbal buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles'per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting.not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 3 .0, 130.2, 1�0.4, 140'�, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a - ight re ve ic e�§­-per-sfte-stlall comply with the applicable requirements in.Sections.1 10,9, 130.0, 1 �0.2, 130.4,114 Voffrilo ni 11KITA I §150.0(k)10: Internally illuminated address signs shall comolywith Section 140.8; 0 n ' ;em.(�bOgft, an n ume 9�T%Mlq 6r no more than five wafts of power as determined according to. §1 30.0(d). EPT. §150.0(k)l 1: Lighting for residential parking garages for eight or more /At-T'hUVED vehicles shall comply with the applicable requirements for nonresidential garages in ectior1g01q.F3(9Q9T*RBbT10N 130.4,140.6, and 141.0. §150.0(k)12A. In a low-rise multi -family residential building where the total interior c mmon area in a'sin le building equals 20 r ercent ,9 1, or less of the floor area, permanently installed lighting for the interior common areas rAMR-)WIdinq'shall tWhiqh efficacy lumin. iires or controlled by an occupant sensor. §150.0(k)12B. In a low-hse multi -family residential building where the total intehor common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.6, 130.6, 130.1,'140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of . ress and egress. rn E Yf nergyPro 6.3 by EnergySoft User Number 57J2. M: LQ 100514L22 Page 13 of 14 HVAC SYSTEM HEATINOAND"COOLING1'.0 DS"SUMMARY _. Project Name Date FOREMOST HOMES INC. Plan 1772 GR 12/5/2014 System Name Floor Area HVAC System 1,772 ENGINEERING-CHECKS,;, :..: ; SYSTEM LOAD Number of S stents ,. ,,. ,_ .. 1: Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL.COOLING CFM 883 0 1 PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 75,000 18,023 1,933 344 13,339 Total Output (Btuh) 75,000 0 Output Btuh/s ft 42.3 1,040 656 Cooling System o 0 Output per System 35,200 0 0 0 0 Total Output Btuh 35,200 0 1,933 0 Total Output (Tons) 2.9 1,040 656 Total Output Btuh/s ft 19.9 Total Output s ft/Ton 604.1 20,104 14,650 Air System CFM perSystem 1,200 HVAC EQUIPMENT,SELECTION Airflow cfm 1,200 York CZE036/PV9C1 6/G1 FA048 23,283 6,479 75,000 Airflow cfm/s ft 0.68 Airflow cfm/Ton 409.1 75,000 Jan.1 AM .; , Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) ......TIME OF SYSTEM PEAK... 1 23,283 6,479 Au 3 PM :.::.:. , . � :., ,.-. 9 .. Outside Air (cfm/s ft) 0.00 Note: values above. even at ARI conditions._ HEATING SYSTEM. PSYCHROMET,RICS (Airst(rearri Teen ratures at. Time of Heoting Peak) 26 OF 67 OF 67 OF 105 OF Outside Air 0 dm Supply Fan Heating Coil 104 OF 1,200 dm l ROOM u, 67°F CITY OF LA QUINTA68°F BUILDING & SAFE I I Y ULH 1. APPROVE® COOLING SYSTEM PSY.CHROMETICS (Airs6eam".T0mpbi6Wres at Time of CC' cling ` � 113/78°F 76/62°F 76/62°F 55/54°F DATE BY Outside Air 0 dm Supply Fan Cooling Coil 56 / 54 OF 1,200 dm 48.0% � ROOM i 76 76 / 62 OF 4 OCI 75 / 62 OF EnergyPro 6.3 by EnengySoft USer Number...5732 ., ,: , . RunCode. 2d14-12-O5fl0 25;33 4Q 100514.'0. , .,_' .: ` Pae 14 6f-14