Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2014-1250
a 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: FOREMOST HOMES 70600 COUNTRY CLUB DR RANCHO MIRAGE, CA 0 BRES2014-1250 52560 AVENIDA HERRERA 773294003 1772 SF $114,914.30 J TO�D / VOICE (760) 777-7125 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 4/2/2015 Owner: FOREMOST HOMES 70600 COUNTRY CLUB DR RANCHO MIRAGE, CA 0 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury. that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. icense Class: B License No.: 926128 ,,^^� ate: 7—It Contractor: �Ah l7ly i YlG GO 4 f 4✓ it �GL, OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of DivisioI of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered forsale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: <!aIt ASIS - Contractor: DANTOR MARTINEZ CONSTRUCTION 81057 AVENIDA ROMERO INDIO, CA 92201 (760)775-4097 Llc. No.: 926128 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:— Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. , ) pate: A-1-- « Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST,'AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cit to enter u n the ab mentioned property for inspection purposes. A .TA �7 `' bate: — Z " % 17 Signature (Applicant or Agent): FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT. PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 1 $5.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $5.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION' ACCOUNT QTY- ' AMOUNT PAID PAID DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 PAID BY METHOD RECEIPT# CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $0.00 PAID BY METHOD RECEIPT. # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF -TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SERVICES 101-0000-42403 0 $24.17 $0.00 s PAID BY . METHOD RECEIPT # CHECK # — CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SERVICES PC 101-0000-42403 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forELECTRICAL: $36.26 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $24.66 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION - ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, EA ADDITION 1,0OOSF, PC 101-0000-42600 0 $10.16 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL FINISH GRADING PC 101-0000-42600 0 $143.00 $0.00 PAID BY METHOD RECEIPT.# CHECK # CLTD BY Total Paid forGRADING: $143.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 PAID BY. METHOD . RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD. RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $36.27 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $14.49 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forMECHANICAL: $188.54 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS 101-0000-20310 0 $537.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forMULTI-SPECIES RESIDENTIAL• $537.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $180.35 $180.35 12/15/14 PAID BY METHOD RECEIPT # CHECK # CLTD BY DANTOR MARTINEZ CONSTRUCTION CHECK R3211 1187 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $315.30 $0.00 PAID BY METHOD RECEIPT # . CHECK # CLTD BY Total Paid for NEW CONSTRUCTION PERMIT: $495.65 $180.35 DESCRIPTION ACCOUNT QTY• AMOUNT PAID PAID DATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,019.65 $1,019.65 12/15/14 PAID BY METHOD RECEIPT # CHECK # CLTD BY DANTOR MARTINEZ CONSTRUCTION CHECK R3211 1187 MFA Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,019.65 $1,019.65 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BUILDING SEWER PC 101-0000-42600 0 $12.09 $0.00 PAID BY, METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000-42401 0 $145.08 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT' QTY AMOUNT PAID PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $145.08 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, S+ OUTLETS 101-0000-42401 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $0.00 PAID BY METHOD RECEIPT # . CHECK # CLTD BY Total Paid for PLUMBING FEES: $435.21 $0.00 DESCRIPTION. ACCOUNT CITY AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $14.94 $0.00 PAID BY. METHOD RECEIPT # CHECK # CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $14.94 $0.00 DESCRIPTION . ACCOUNT CITY AMOUNT PAID PAID DATE SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 $0.00 PAID'BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forTUMF - RESIDENTIAL:. $1,837.44 $0.00 TOTALS:4• $1,200.00 Description: 1772 SF ADDITIONAL Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: APPROVED Applied: 12/15/2014 MFA FAMILY DETACHED CHRONOLOGY TYPE Approved: 3/5/2015 JFU Parcel No: 773294003 Site Address: 52560 AVENIDA HERRERA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 151 Lot: 21 Issued: UNIT 16 3/19/2015 3/19/2015 EMAILED MR FORTSON SCHOOL FEE LETTER, THIS IS THE LAST Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $114,914.30 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 AJ ORTEGA Details: 1,772 SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2013 CALIFORNIA BUILDING CODES. -J Applied to Approved Printed: Thursday, April 02, 2015 9:56:15 AM 1 of 7 CR SYS7cMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AJ ORTEGA 3/19/2015 3/19/2015 EMAILED MR FORTSON SCHOOL FEE LETTER, THIS IS THE LAST REMAINING ITEM NECESSARY FOR ISSUANCE. EMAILED MR FORTSON ALL REMAINING ITEM NECESSARY E-MAIL AJ ORTEGA 3/23/2015 3/23/2015 FOR ISSUANCE HAVE BEEN RECIEVED, PERMIT IS READY TO ISSUE TO CONTRACTOR. NOTE AJ ORTEGA 1/7/2015 1/7/2015 MANUALLY ADJUSTED FEES FOR SOFTWARE MISCALCULATION OF BUILDING PLAN CHECK AND CONSTRUCTION FEES. NOTE ANGELICA ZARCO 3/20/2015 3/20/2015 RECEIVED SCHOOL FEE CERTIFICATION FROM SCHOOL DISTRICT. NOTE KAY HENSEL 3/2/2015 3/2/2015 PLANS WERE ACTUALLY RESUBMITTED TO STEPH ON 2/27/2015, BUT PROCESSED ON 3/2/2015. PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 2/13/2015 2/13/2015 STRUC PLAN CHECK APPROVABLE 2/12/2015 RECEIVED Printed: Thursday, April 02, 2015 9:56:15 AM 1 of 7 CR SYS7cMS PLAN CHECK COMMENTS PLAN CK COMMENTS RELIEVED FROM YOUNG 1-05-2015 FROM CONSULTANT PHILIP JUAREZ 1/6/2015 1/6/2015 STRUCTURAL NOT APPROVABLE. RECEIVED PLANS, CALCULATIONS AND COMMENTS PICKEDUP BY PLAN CHECK PICKED UP AJ ORTEGA 1/8/2015 1/8/2015 DANNY MARTINEZ. PLAN CHECK PICKED UP MARY FASANO 2/17/2015 2/17/2015 APPLICANT PICKED UP PLANS FOR REVISIONS PLAN CHECK SUBMITTAL KAY HENSEL 12/15/2014 12/15/2014 PLANS SUBMITTED TO M.F. AT FRONT COUNTER. RECEIVED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 1/28/2015 1/29/2015 SENT TO YOUNG RECEIVED SENT TO PLAN CHECK KAY HENSEL 12/15/2014 12/15/2014 STRUC TO YOUNG - DUE 1/5/15 CONSULTANT LEFT MESSAGES W/ FOREMOST HOMES AT (760) 537-1502 AND ESCOBAR DESIGNS AT (760) 289-9221 NOTIFYING THEM TELEPHONE CALL JAKE FUSON 1/7/2015-- 1/7/2015 PLAN REVIEW WAS COMPLETE AND REVISIONS WERE REQUIRED. NOTIFIED DANTOR MARTINEZ CONSTRUCTION AT (760) 984 - TELEPHONE CALL JAKE FUSON 2/17/2015 2/17/2015 0091 THAT PLAN REVIEW WAS COMPLETE AND REVISIONS REQUIRED. TELEPHONED ESCOBAR DESIGNS TO NOTIFY THEM PLANS TELEPHONE CALL JAKE FUSON 3/5/2015 3/5/2015 WERE APPROVED. PENDING ITEMS: GRANT DEED AND SCHOOL FEES. CONDITIONS CONTACTS NAME TYPE NAMEo ADDRESS1. CITY STATE ZIP PHONE FAX EMAIL - APPLICANT FOREMOST HOMES 70600 COUNTRY CLUB RANCHO CA 0 DR MIRAGE CONTRACTOR DANTOR MARTINEZ CONSTRUCTION 81057 AVENIDA INDIO CA 92201 ROMERO OWNER FOREMOST HOMES 70600 COUNTRY CLUB RANCHO CA 0 DR MIRAGE Printed: Thursday, April 02, 2015 9:56:15 AM 2 of 7 SYS TEMS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTO . BY BSAS SB1473 FEE 101-0000-20306 0 $5.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $5.00 $0.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $0.00 DIF - COMMUNITY 254-0000=43200 0 $129.00 $0.00 CENTERS DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $0.00 DIF - LIBRARIES 253-0000-43200 0 $344.00 $0.00 DIF - PARK 256-0000-43200 0 $40.00 $0.00 MAINTENANCE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $0.00 DIF - STREET 255-0000-43200 0 $116.00 $0.00 MAINTENANCE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $0.00 Total Paid forDIF - SINGLE FAMILY DWELLING: $6,894.00 $0.00 SERVICES 101-0000-42403 0 $24.17 $0.00 SERVICES PC 101-0000-42403 0 $12.09 $0.00 Total Paid for ELECTRICAL: $36.26 $0.00 RESIDENTIAL, EA 101-0000-42403 0 $24.66 $0.00 ADDITION 1,000SF RESIDENTIAL, EA 101-0000-42600 0 $10.16 $0.00 ADDITION 1,000SF, PC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $0.00 1,000SF RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $0.00 1,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $0.00 Printed: Thursday, April 02, 2015 9:56:15 AM . 3 of 7 Ci? SYSTEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD - BY . RESIDENTIAL FINISH 101-0000-42600 0 $143.00 $0.00 GRADING PC Total Paid forGRADING: $143.00 $0.00 CONDENSER/COMPRES 101-0000-42402 0 $36.26 $0.00 SOR CONDENSER/COMPRES -101-0000-42600 0 $24.17 $0.00 SOR PC EXHAUST HOOD 101-0000-42402 0 $12.09 $0.00 EXHAUST HOOD PC 101-0000-42600 0 $4.83 $0.00 FURNACE 101-0000-42402 0 $36.26 $0.00 FURNACE PC 101-0000-42600 0 $24.17 $0.00 VENT FAN 101-0000-42402 0 $36.27 $0.00 VENT FAN PC 101-0000-42600 0 $14.49 $0.00 Total Paid for MECHANICAL: $188.54 $0.00 MULTI -SPECIES RESIDENTIAL 8.1-14 101-0000-20310 0 $537.00 $0.00 UNITS Total Paid for MULTI -SPECIES RESIDENTIAL* $537.00 $0.00 NEW CONSTRUCTION 101-0000-42400 0 $180.35 $180.35 12/15/14 R3211 1187 CHECK DANTOR MARTINEZ MFA PERMIT CONSTRUCTION NEW CONSTRUCTION 101-0000-42400 0 $315.30 $0.00 PERMIT Total Paid forNEW CONSTRUCTION PERMIT: $495.65 $180.35 NEW CONSTRUCTION 101-0000-426000 $1,019.65 $1,019.65 12/15/14 R3211 1187 CHECK DANTOR MARTINEZ MFA PLAN CHECK CONSTRUCTION Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,019.65 $1,019.65 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $0.00 Printed: Thursday, April 02, 2015 9:56:15 AM 4 of 7 CO? SYSTEMS Printed: Thursday, April 02, 2015 9:56:15 AM 5 of 7 CRT SYSTEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY • - BY BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $0.00 BUILDING SEWER 101-0000-42401 0 $12.09 $0.00 BUILDING SEWER PC 101-0000-42600 0 $12.09 $0.00 FIXTURE/TRAP 101-0000-42401 0 $145.08 $0.00 FIXTURE/TRAP PC 101-0000-42600 0 $145.08 $0.00 GAS SYSTEM, S+ 101-0000-42401 0 $36.26 $0.00 OUTLETS GAS SYSTEM, 5+ 101-0000-42600 0 $24.17 $0.00 OUTLETS PC WATER HEATER/VENT 101-0000-42401 0 $12.09 $0.00 WATER HEATER/VENT 101-0000-42600 0 $7.25 $0.00 PC WATER SYSTEM 101-0000-42401 0 $12.09 $0.00 INST/ALT/REP WATER SYSTEM 101-0000-426000 $12.09 $0.00 INST/ALT/REP PC Total Paid for PLUMBING FEES: $435.21 $0.00 SMI - RESIDENTIAL 101-0000-20308 0 $14.94 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $14.94 $0.00 SINGLE FAMILY 224-0000-203200 1 $1,837.44 $0.00 F DETACHED Total Paid forTUMF - RESIDENTIAL: $1,837.44 $0.00 TOTALS:• $1,200.00 • SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE - FINAL*" Printed: Thursday, April 02, 2015 9:56:15 AM 5 of 7 CRT SYSTEMS Printed: Thursday, April 02, 2015 9:56:15 AM 6 of 7 9?w.,Y57EM5 PARENT .O ATTACHMENTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED ,: STATUS REMARKS NOTES BRES2014-1250 - DATE DOC 3/19/2015 NON-STRUCTURAL JAKE FUSON 12/15/2014 1/5/2015 1/7/2015 REVISIONS REQUIRED CORRECTIONS SEE ATTACHED REVIEW. PLANNING WALLY NESBI7 12/15/2014 12/29/2014 12/29/2014 COMPLETED COVE CHECK - OK CERTIFICATION.pdf KATHRYN 12/15/2014 1/5/2015 12/15/2014 REVISIONS REQUIRED CORRECTIONS BRES2014-1250 - CSLB STRUCTURAL SAMUELS DOC 3/19/2015 AJ ORTEGA INFORMATION LICENSE INFORMATION STRUC TO YOUNG - DUE 1/5/15 FIRE JACQUELINE 1/26/2015 2/9/2015 2/4/2015 APPROVED - GARCIA VERIFICATION) VERIFICATION).pdf CONDITIONS NON-STRUCTURAL JAKE FUSON 1/28/2015 2/11/2015 2/4/2015 REVISIONS REQUIRED CORRECTIONS SEE ATTACHED SECOND REVIEW CORRECTIONS. YOUNG 1/28/2015 2/11/2015 2/13/2015 APPROVED STRUC APP 2/12/2015 AJ ORTEGA STRUCTURAL ENGINEERING 0 NON-STRUCTURAL JAKE FUSON 2/27/2015 3/13/2015 3/5/2015 APPROVED APPROVED READY FOR 3RD N/S P/C. STRUCTURAL ALREADY COMPLAINCE.pdf APPROVED 1ST PW GREEN AMY YU 3/3/2015 3/13/2015 3/3/2015 APPROVED PM -10 ONLY SHEET 1 PM -10 ONLY Printed: Thursday, April 02, 2015 9:56:15 AM 6 of 7 9?w.,Y57EM5 ATTACHMENTS Attachment Type ' CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BRES2014-1250 - DOC 3/19/2015 AJ ORTEGA SCHOOL FEE SCHOOL FEE 0 CERTIFICATION CERTIFICATION.pdf CSLB LICENSE BRES2014-1250 - CSLB DOC 3/19/2015 AJ ORTEGA INFORMATION LICENSE INFORMATION 0 (WORKERS COMP (WORKERS COMP VERIFICATION) VERIFICATION).pdf BRES2014-1250 - SCHOOL FEE DOC ' 3/23/2015 AJ ORTEGA CERTIFICATION OF SCHOOL FEE 0 CERTIFICATION OF COMPLAINCE COMPLAINCE.pdf Printed: Thursday, April 02, 2015 9:56:15 AM 6 of 7 9?w.,Y57EM5 Printed: Thursday, April 02; 2015 9:56:15 AM 7 of 7 CN?wf 1W EV SYSTEMS ATTACHMENTS Attachment Type CREATED OWNER —DESCRIPTION: . _ PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/4/2015 JAKE FUSON NON-STRUCTURAL - NON-STRUCTURAL - 0 SECOND REVIEW SECOND REVIEW.pdf DOC 2/4/2015 JAKE FUSON NON-STRUCTURAL - NON-STRUCTURAL - 0 FIRST REVIEW FIRST REVIEW.pdf LAQ-I5-RS-040 Lot 21 LAQ-I5-RS-040 Lot 21 DOC 2/4/2015 JACQUELINE GARCIA 52560 Avenida 52560 Avenida 0 Herrera.docx Herrera.docx 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 1/29/2015 STEPHANIE KHATAMI CORRECTION LIST AND CORRECTION LIST AND 0 CORRECTIONS CORRECTIONS BRES2014-1250.pdf BRES2014-1250.pdf DOC 3/5/2015 STEPHANIE KHATAMI PM10 APPROVAL 3-5-15 PM10 APPROVAL 3-5- 0 15. pdf Printed: Thursday, April 02; 2015 9:56:15 AM 7 of 7 CN?wf 1W EV SYSTEMS DESCRIPTION • QTY PAID $10:(3'+4, ...yy, .c �t,.f#«}•;s..J. +� k': v;:�,' ,i s'�•x ivt.' +�SsY).'_;i.rr 't1er �' 4xai...0 , 3'. "^2:'. ..7 . '>t • i .w - nv 4 _� �,BRES2014 1250° T `Address. 5256UkAVENIDA{�HERRERA ,rA n 7,73294003 T � `x ,g�$10,634.401! �.w,.]'... a.bS Fe!i,mr_ :'lt>'�e;:..+�i:Y�V—E'.C.-: 1:iT s.}"Yp.1•a:3.i-C.. Kfi r"--. A32 -,NEWCONSTRUCTION PERMIT. f F ,ao "' : ;r. x F x "E4 'r NEW CONSTRUCTION PERMIT 101-0000-42400 0 $315.30 71 PLUMBING FEES Y fa 7 �. ��� �, �5 } t� T..�a' si i #s:w J ri : ..:?iJ ''tiv+'i wE e2u" ♦GY!�L{'. y rchJ:i. �litn lt'�. -4 ..YsiL. �C .'�'. .sM♦ is $435.21 YM:S BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 BACKFLOW DEVICE 101-0000-42401 0 $12.09 BUILDING SEWER PC 101-0000-42600 0 $12.09 BUILDING SEWER 101-0000-42401 0 $12.09 FIXTURE/TRAP PC 101-0000-42600 0 $145.08 FIXTURE/TRAP 101-0000-42401 0 $145.08 GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $24.17 GAS SYSTEM, 5+ OUTLETS 101=0000-42401 0 $36.26 WATER HEATER/VENT PC 101-0000-42600 0 $7.25 WATER HEATER/VENT 101-0000-42401 0 $12.09 WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 V..cstkONG MOTIONINSTRUMENTATION SMle�+i t,4� # .t�.� 1w:i F' •�7 v r•''T�s►' _#�. S ' $14:94,x' SMI - RESIDENTIAL 101-0000-20308 0 $14.94 i• 3,, ., `}.'TUM= - . r '�.s. .� Yi r. l s : u , "-I a* ' •'$44RESIDENTIAL "2 SINGLE FAMILY DETACHED TOTAL$10,634.40 224-0000-20320 0 $1,837.44 Date Paid: Thursday, April 02, 2015 Paid By: FOREMOST HOMES Cashier: PJU Pay Method: CHECK 4515 Printed: Thursday, April 02, 2015 10:04 AM 2 of 2 CRX 9/ CVfTF AAf DESCRIPTION... ACCOUNT QTY. PAP Pie it TRA re VEN ERR STAN iNi ib' DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DIF - PARK MAINTENANCE 25.6-0000-43200 0 $40.00 DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DIF -TRANSPORTATION 250-0000-43200 0 $2,842.00 SERVICES PC 101-0000-42403 0 $12.09 SERVICES 101-0000-42403 0 $24.17 ST R UCTIO N: RESIDENTIAL, EA ADDITION 1,OOOSF 101-0000-42403 0 $24.66 RESIDENTIAL, EA ADDITION 1,OOOSF, PC 101-0000-42600 0 $10.16 RESIDENTIAL, FIRST 1,OOOSF 101-0000-42403 0 $145.03 RESIDENTIAL, FIRST 1,OOOSF, PC 101-0000-42600 0 $47.86 IN RESIDENTIAL FINISH GRADING PC, 101-0000-42600 0 $143.00 CONDENSE R/COM PRESSOR PC 101-0000-42600 0 .$24.17 CON DEN SER/COM PRESSOR 101-0000-42402 0 $36.26 EXHAUST HOOD PC 101-0000-42600 0 $4.83 EXHAUST HOOD -101-0000-42402 0 $12.09 FURNACE PC. 101-0000-42600 .0 $24.17 FURNACE 101-0000-4240.2 0 $36.26 VENT FAN PC 101-0000-42600 0 $14.49 VENTFAN 101-0000-42402 0 $36.27 -SPECIES RESIDENTIA MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS 101-0000-20310 1 0 ;537.00 Date Paid: Thursday, April O2,3O1S Paid By: FOREMOST HOMES Cashier:P1U Pay Method: CHECK 4515 Printed: Thursday, April Q2,ZD151O:044M 1ofZ =,�_, I1 C . P.O. BOX 1504 Building 78 495 CALLE TAMPICO Address - �� ,aIJ4 A, CALIFORNIA 92253 anu iy(,,�'�'� Address -1b `C�0 V C Jb Dr. City Zip Tel. `��inClnro � 1'�' 12214 �ln_�-531-1�2 wIIt[ CIL; UI� �J` 1 c1e2Cft 6 La'ON Address �OT l�1 � 4eY)Wt KzlmeIW city `s Zip �2� 1W �Q 1 State Lic. 12A 'h City & Classif. -I (� Lic. # rvcn., r-nyr., Designergel n hov Des l CP h S HOareSS L'Irywae 0y j b I Lipl Z2.o l ILic?# I LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) Division 3 of th Business and Professions Code, and my license is in full force and effect WSIGNKrURDATE OWNER -BUILDER DECLARATION hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not appty to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractors) licensed pursuant to the Contractor's License Law.) 01 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT 1w-162-%Azi APPLICATION ONLY BUILDING: TYPE CONST.' OCC. GRP. A.P. Number]13 - Z t . 00✓ Legal Description W ( 21. 5C-• 5(Q D.�/e ACI kiff-' A Project Description V� S e K S Ft. No. No. Dw. Ste �� Stories Units Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading AMOUNT Driveway Enc. Infrastructure TOTAL , CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setback from Center Line — Rear Setback from Rear Prop. Line _ Side Street Setback from Center Line Side Setback from Property Line — FINAL DATE— Issued by: Validated by: — Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE Lots 21 and 22 in Block 151 of Santa Carmelita at Vale La Quinta Unit 16, as per map recorded in Book 18 Page(s) 99, records of Riverside County; California. Commonly known as: APN # 773-294-002-0 & 773-294-003-1 , La Quinta, CA 92253 Date J sal M. Docimo STATE OF CALIFORNIA COUNTY OFT )S.S. _. . \(/moi (0—Y On rq( n� its LO ( --t;' before me, 114) x -r Ir- - a Notary Public in and for -said County. and State, personally appeared Josal M. Docimo who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS m hLandfficial seal. Signature MAIL TAX ST4,fE'I�U=�7� 1"O %A%AE AS ABOVE ---------- - ----- SHARON F. CHUN COMM. #1960267 NOTARY PUBLIC • CALIFORNIAN • RNERSIDE COUNTY CwtrissW Efts DEC 8, 2015 + DOC # 2013-0217723 05/08/2013 08:00 AM Fees: $15.00 Page 1 of 1 Doc T Tax Paid Recorded in Official Records RECORDING REQUESTED BY: County of Riverside Larry W. Ward Assessor, County Clerk & Recorder AND WHEN RECORDED MAIL TO: AND MAIL TAX STATEMENT TO: —This Foremost Homes., LLC < 0 � document was electronically submitted to the County of Riverside for recording" 70600 Country Club Dr. Rancho Mirage, CA 92270 —I Receipted by: LJONES rrnn r - Order No. 158638 M Escrow No. 13-5102DS lParcel No. 773-294-002-0 7773-294-003-1 SPACE ABOVE THIS LINE FOR RECORDER'S USE `q� 02,C) GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) THAT DOCUMENTARY TRANSFER TAX IS 393 X computed on full value of property conveyed, or computed on full value less liens or encumbrances remaining at the time of sale. unincorporated area: OR City of La Quinta and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, 11G 1 92013 Josal M. Docimo, an unmarried woman C "-y OF LA COMMUVITM hereby GRANTS to Foremost Homes, LLC DEV�ELOPMEN T the following described real property in the County of Riverside, State of California: Lots 21 and 22 in Block 151 of Santa Carmelita at Vale La Quinta Unit 16, as per map recorded in Book 18 Page(s) 99, records of Riverside County; California. Commonly known as: APN # 773-294-002-0 & 773-294-003-1 , La Quinta, CA 92253 Date J sal M. Docimo STATE OF CALIFORNIA COUNTY OFT )S.S. _. . \(/moi (0—Y On rq( n� its LO ( --t;' before me, 114) x -r Ir- - a Notary Public in and for -said County. and State, personally appeared Josal M. Docimo who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS m hLandfficial seal. Signature MAIL TAX ST4,fE'I�U=�7� 1"O %A%AE AS ABOVE ---------- - ----- SHARON F. CHUN COMM. #1960267 NOTARY PUBLIC • CALIFORNIAN • RNERSIDE COUNTY CwtrissW Efts DEC 8, 2015 + Lot # No. Street Unit 1 52560 Avenida Herrera Unit 2 Unit 3 Unit 4 Unit 5 S.F. Lot # No 1585 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Comments 11/22/13 , Cert #31889, paid for 1,585 sq ft. New total = 1,772 sq ft Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.16 X 1,585 S.F. or $253.60 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC -California Bank & Trust - James Fortson Bank Name/Recipient of Certificate By Dr. Gary Rutherford Superintendent Fee collected /exempteffi5by Shdro6 M Signature Check No. 467537 Telephone Funding Residential Payment Recd $0.00 $253.60 ager/UInd ef - NOTICE: Pursuant to Government Code Section 66020(d)(1), this will khe to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - ApplicanUReceipt Copy - Accounting Date 3/20/15 No. 31748 Owner Foremost Homes, LLC Address 76600 Country Club Dr City Rncho Mirage Zip Tract # Type New Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 Lot # No. Street Unit 1 52560 Avenida Herrera Unit 2 Unit 3 Unit 4 Unit 5 APN # Jurisdiction Permit # No. of Units S.F. Lot # No. 187 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 BERMUDA DUN r rn RANCHO MIRAGE ('7 INDIAN WELLS PALM DESERT �Qw©OTy��ti 773-294-003 La Quinta 1 Street Comments 11/22/13 , Cert #31888, paid for 1,585 sq ft. at $3.20/sf. New total = 1,772 sq ft S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.36 X 187 S.F. or $628.32 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC-- California Bank & Trust - James Fortson Check No. 46537 Bank Name/Recipient of Certificate Telephone Funding Residential BY Dr. Gary Rutherford Superintendent Fee collected /exemp d by aro CGily y Payment Recd ^ : $0.00 $628.32 Ever/Under, Signature NOTICE: Pursuant to Government Code Section 66020(d) 1), thi will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the 4tewhich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another _.Jin lic entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting �F�Q�rw COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7012 FAX (760) 777-7011 CERTIFICATION OF BUILDING AREA STREET ADDRESS OF JOB: 52-560 AVENIDA HERRERA t APN: 773 — 294 — 003 . DESCRIPTION OF WORK: SINGLE FAMILY DWELLING ,SQUARE FOOTAGE: 1,772] OWNER'S NAME: FOREMOST HOMES ***NOTE: OWNER HAS ELECTED TO WITHDRAW PREVIOUS APPLICATION FOR CONSTRUCTION. OF 1,585SF DWELLING, FEES PREVIOUSLY PAID 11/22/2013, NUMBER 31888 — THIS CERTIFICATION OF BUILDING AREA IS BEING ISSUED PURSUANT TO CITY OF LA QUINTA POLICY, ANY CREDIT OF FEES SHALL BE DETERMINED AT THE DISTRICTS DISCRETION*** For questions regarding this letter, please call: City of La Quinta Permit Center (760) 777-7012 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVES . FOR CONSTRUCTION DATe 3 141 'IAt Please note: This letter verifies conditioned square footage. Please call - your School District to verify school fees, requirement for cashier's check or money order and hours of operation. 7 Wwbo-Si-6 POS00 any 4 ueyf ss�r QEWd S lsAo� 1.3�HS M2�NJ1sua„tea+!Cdy q suuFa�lSuoP�t?QdV 4 EwJoj • 3rnf aN�1',1 ,I!WgnsaJ PUB 109JJQO aseald `(s)mollol se (s)uoseaa aol lenoadde aol poutloa( luawlaeda(3 Buluueld of laagg uaaa0 ( } '7luQ Dl." AtaleS T 6ulplln8 of taagg uaa.tO (,r�" ) :uotingt.uslQ s)PDAA otlgnd ':91e( :Aq papuawwoaaa #els Allo Kq po;oldwoo uol�aas s141 -aouensst'llwjad 6utpttnq aol Pasealaa eq Aew loafoad anoge ay} `s6utpug Aw of luensind '(s)tol loofgns ayl, uo su6tslsllem/sainian4s/s6utplrnq pasodoad ay1 to uoganatsuoo aol alaldwoo blluagglns aq 01 sluawanoidwt ayt pug pue palussaad se anoge palstl sluawaitnbaa aql pauujuoo pue paMatna.r aney I r r x se'yoaeas ua/�ldayOueld/ ao etutn-efmM^'+Il; qy �iu!16utMollol041 le,pannaln ag Aew sueld/edew panoiddy 'waol uolldwaxe dV40M paieldwoo a ao dWDM,e aaglla aatnbea stoofoid uorlonalsu0a 6ulpllnq panoadde Md 'aigeolldde p 'waol uotldwaxe (dWDM). ueld luawaBeuew tgllenb aalenm Paquette ay; u6ts pue alaldwo( suopellelsul A1!Itoel letaads io deaf aseaA 'u6ls.luawnuow weld Clem ao1 uolleluawnoop 6ullloddns yoe4V -ueld tuawdalanap Meld pool} pano,rdde ue aannbei lilm sluawdolanap auoz pooh OV •uolleoglaan uollenaja ped aol (s)uorleool 6ulpllnq butmogs luaw}aedaD sMaoM oilgnd aql al ueld 8utpeA aspaad as y6noi ayl lo.4doo a LpegV 'paltnbaa sl aaquanu uolleogtlaao 0 t Wd luaaana y swawaatnbe leuay►ppe of loafgns aae V sueld 6u1016 Rm etlaleaedas poutwgns aae (loll puoAaq) sluawdolaAep laguaptsaa V lepiewwoo ao1 sueld 06Wd -ueld Adoa paey ao .iagwnu aduaaa/da las veld 01,Wd panoadde Apo Poen '8 0fittew8lle spinoud ao luaweer6e ,g ueld MW 'waol uollewaolut pefoad lo.rluoO lsn(3 angl6nd loefoad 11gut ao 1ol aed one 1> peyoepe eql alaldwo( slot le6al aae suogeool 6ulpllnq pasodoad Buimoys paep luea6luollewao;w alp; ao dew teug papaooa.t goetty tuaweimbei styl woa; ldwaxa aie uogeogtiao leatu4081096 panaidde Aisnolnaad a aneg golym sluawdolanap ,letluaplsaa popeA 46nw Anua " -jaaul6u3 silos pasuawl a woal sliodej uotlaedwoo 6utpnlout eouelidwoo ueld 6ulpeA to uolleoggiao Ieotuyoaloa6 goe:gV •paptnoad aq ueo aleogilaaO UOIlen813 ped a lgun letttwgns" leags uaaa6 ployyllM aseald 'lenoadde aol ped agt sateen ueld 6ulpea6 astoaad a 11 •(alep luaamo 10 stt)uow g utgl!m) luaaarso aq lsnw sateogtt,a( uotlena13 ped '(1001 i•0 /+1a uolterAap algemolle wnwlxew) ped-6ulpltnq aol uopenala u6tsap panoidde egt 41!m aauelldwoa ul saleogtlraO u01ten913 ped goetttt •' quawlaeda( A1a18S,2 bulpllne ayl wail l!waed 6ulpllnq a lo-aouenssl wpoglne of ooueaealO s)poM_allgnd aol stuaeua tnbaUtCt�aaa a e 6ur�+nollol aql _ rc,Si�L�,�, • }�� n - E qq( :aagWnN au048 dfildQi°S—z–S .(s)ssalpp`d :W'oN 10-1 :aweN heal :•0N IMI a (1 :jedoleAeC] Cpl -ale( s ' •lueotldde of peuanlaa"eq Iltm poss000ad eq louueo yotym suotleutidde.o suotleotidde alaldwooul •alaldwoo eae molaq palstl sluawaalnbaa -11V ltlun tuampeda( sj1oM ollgna agl 01 1a)sed (aoueaealO WoM oggnd) 1e04S uaaaO agl ltwgns ION 00 aseald s5PcYM5llqfro:&q , -s` 1p a . O".. S'8 AUjpjjnj oqj,,oj,Ppe SIR.—Judo 1554 O. 600Zl4L/6 onrlooge g.po pdn uuaf L1WH3d ONimin9 d0.3SV3"1328 2803 3ON'd V3` 0 Sm0M onand I ' 133HS N33HO 1N3W1HVd3G S)iHom onand - V1Nino Vi d0 Juio Pe"r hit Nur _ er:-BRES2014-1250-__�- Vis` Description:1772 SF Applied: 1-2/15/2014 Approved: Site Address -52560 AVENIDA HERRERA Imed: Finaled: City, State Zip Code: LA QUINTA, CA 92253 Status: UNDER REVIEW Applicant: <NONE> Parent Permit:Owner:-FOREMOST•HOMES-_, ' Parent Project: Contractor: DANTOR MARTINEZ CONSTRUCTION Details: e xrS� N' 101 '` h1 z �,r RETU;RIVED• }�b';x SENT D'A. TE > :. kDUEpATE TYPES r CONTACT ''} STATUS• REMARKS - } wa,gu�x DATE tygtsx� . y x Cy *, ..:Le�2�''4`%^ihy��i:':iig;4i•Ie°_R d`.'�' w 'Y6''...ta rik<:i 1s51A "S"t5.": fleL�x?f:`4i.r�.''fi�ifri"'.1":Li .•kf.T: Fi v�A :f `��' 4"L+d:a*�,3'�`Nr�'i'+F�:f"Y+» Review Group: BLDG 1ST (3WK) 4 " is Pe"r hit Nur _ er:-BRES2014-1250-__�- Vis` Description:1772 SF Applied: 1-2/15/2014 Approved: Site Address -52560 AVENIDA HERRERA Imed: Finaled: City, State Zip Code: LA QUINTA, CA 92253 Status: UNDER REVIEW Applicant: <NONE> Parent Permit:Owner:-FOREMOST•HOMES-_, ' Parent Project: Contractor: DANTOR MARTINEZ CONSTRUCTION Details: e xrS� N' 101 '` h1 z �,r RETU;RIVED• }�b';x SENT D'A. TE > :. kDUEpATE TYPES r CONTACT ''} STATUS• REMARKS - } wa,gu�x DATE tygtsx� . y x Cy *, ..:Le�2�''4`%^ihy��i:':iig;4i•Ie°_R d`.'�' w 'Y6''...ta rik<:i 1s51A "S"t5.": fleL�x?f:`4i.r�.''fi�ifri"'.1":Li .•kf.T: Fi v�A :f `��' 4"L+d:a*�,3'�`Nr�'i'+F�:f"Y+» Review Group: BLDG 1ST (3WK) 12/185/2014 1/5/2015 NON-STRUCTURAL JIM JOHNSON - k,�'f - D f 5 N �Sy i 4 k�}•.,:C��&pP Notes F. '�i ("_12/15/2014____-12/29/2014___ 11/29/2014��'�PLANNING WALLYNESBIT COMPLETED COVE CHECK -OK �..�N �eS ��,, .��� f d<:'"��;�n, y ^ ` ;�'' �,, ���� � j t '� �,�'������•�n P v�� -H,'�� �'�"�����w � �"�,.-^ '�t� ? "�sKy., `i➢� `'is �'� _;3 6 r � � �a � � L� � P . ,� Y�'i! ,F :,. '>�` 3 Fx r .: aR ,, � :�` � � t � � �s5+,•,, �,.. , '�.w�I,� �P�' i ,�� `�P a; � > a pp Y�a���,gv gs� 12/15/2014. 12/15/2014. 1/5/2015 r ,1 STRUCTURAL KATHRYN SAMUELS . r- 4q is' �5 RAI,. �" ` ` - � 3 _y t ; ''" l: 5 ^ 'i? "� a `�•r� .E, � ',.` . , A"�,. a,�.i' 9 sg iE ` ,y.. a. Notes', ` Ec±1 kd'i'aZr BUILDING ENERGY ANALYSIS`REPORT PROJECT: FOREMOST HOMES INC. Plan 1772 GL Lot 21 Avenida Herrera - A. P.N.: 773-294-003 La Quinta, Ca 92253 Project Designer: ESCOBAR DESIGNS 43927 Pacific Ave. Indio, Ca 92201 760.289.9221 Report Prepared by: Santiago Lopez-Ocampo Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 Job Number: LQ 120514 L21 Date: 12/5/2014 CITY OF LA QUINTA . BUILDING $ SAFETY DEPT APPR®VED FOR CONSTRUCTION DATE 3��22001438y Moak EIVED JAN 2 8.2015 C""yOF LA C®PyMU'WM DeVEd®PMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 6.3 by EnergySoft User Number. 5732 ID: LQ120514 L21 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary I EnergyPro 6.3 by EnergySoft Job Number: ID: L0120514 L21 User Number: 5732 1 2 3 11 14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xml CF1 R-TPRF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name FOREMOST HOMES INC. 02 Calculation Description Title 24 Analysis - 03 Project Location Lot 21 Avenida Herrera - A. RN.: 773-294-003 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FTZ) 1772 15 Number of Zones 1 16 Slab Area (FTZ) 1772 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FTZ). N/A 21 Glazing Percentage (%) 10.5% COMPLIANCE RESULTSARC 01 Building Complieswith Computer Performance; .; 02 This building Incorp rates features that require field testing andlor ve(Ification£by acertified HERSR ater under the supervision of a CEC-approved HERS provider. 03 This building P incor orates one or more`. ociat-Featuresahown below P - - ENERGY USE SUMMARY 04 06 06 07 08 Energy Use (kTDV/ft) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.34 0.76 -0.42 -123.5% Space Cooling 95.43 96.52 -1.09 -1.1% IAQ Ventilation 1.20 1.20 0.00 0.0% Water Heating 13.63 11.33 2.30 16.9% Photovoltaic Offset --- 0.00 0.00 -- Compliance. Energy Total 110.60 109.81 0.79 0.7% Registration Number: 214-NO153178A-000000000-0000 Registration Date/Time: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation DatefTime: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation CF1 R=PRF-01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: — None — ENERGY DESIGN RATING 4, £ a .:,:.ANNs _:_ .... ... This is the sum of the annual TOV energy consumption for energy use components included in the performance compliance approach fog the Standard Design Building (Energy Budget) and the annual TIT/ energy consumption for lighting and components not regulated by Tit(e_24 Part 6."- {such as domestic appliances,and: corisumer elecfronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Usenergy Design Rating Margin Percent Improvement Total Energy (kTDV/f2)" 160.69 169.90. 0.79 0.5% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems FOREMOST HOMES INC. 1772 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned HVAC Systeml 1772 9 DHW Sys 1 Registration Number: 214-N0153178A-000000000-0000 Registration Date/rime: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Page 3 of 8 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xml OPAQUE SURFACES 01 02 03 04 05 06 07 NameConsfruction W& i:a.x..' :. Roof Ri"se 01 02 03 04 - 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window Area (ft2) Tilt(deg) Ri/S 44.66'x 9' Whole House R-15 Wall 180 Right 402 9.2 90 Re/E 41' x 9' Whole House R-15 Wall 90 Baric 369 96 90 Le/N 44.66'x 9' Whole House R-15 Wall 0 Left 402 56 90 Fr/W 41' x 9' Whole House R-15 Wall 270 Front 369 25 90 Roof Whole House R-38 Roof Attic w/Radiant - -- 1 48.0 400 0.23 Insect Screen (default) Roof 2 Whole House R-38 Roof Attic w/Radiant - -- 1 48.0 564 0.23 Insect Screen (default) Roof 3 Whole House R-38 Roof Attic w/Radiant - -- 1 6.0 564 0.23 Insect Screen (default) Roof 4 Whole House R-38 Roof Attic w/Radiant - -- 1 25.0 244 0.23 Insect Screen (default) ATTIC 01 02 03 04 05 06 07 NameConsfruction W& i:a.x..' :. Roof Ri"se Roof Reflectance; Roof Emittance Radiant Barrier Cool Roof etF<.u:.... Attic £ Attic Roof Cons 03 0 1 ` „ 0.85 Yes No 07 08 09 WINDOWS_- 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height Width(ft) (ft) Multiplier Area (W) U -factor SHGC Exterior Shading 1616 Wndow Ri/S 44.66'x 9' (Right -180) - -- 1 2.3 0.30 0.23 Insect Screen (default) 16162 Window Ri/S 44.66'x 9' (Right -180) - -- 1 2.3 0.30 0.23 Insect Screen (default) 16163 VVlndow Ri/S 44.66'x 9' (Right -180) - -- 1 2.3 0.30 0.23 Insect Screen (default) 16164 Window Ri/S 44.66'x 9' (Right -180) - -- 1 2.3 0.30 0.23 Insect Screen (default) 6080 Wndow Re/E 41'x 9' (Back -90) - -- 1 48.0 0.28 0.23 Insect Screen (default) 60802 Window Re/E 41'x 9' (Back -90) - -- 1 48.0 0.28 0.23 Insect Screen (default) 2030 Window Le/N 44.66'x 9' (Left -0) - -- 1 6.0 0.30 0.23 Insect Screen (default) 5050 Window Le/N 44.66'x 9' (Left -0) - -- 1 25.0 0.30 0.23 Insect Screen (default) 50502 Window Le/N 44.66'x 9' (Left -0) - -- 1 25.0 0.30 0.23 Insect Screen (default) 50503 Window Fr/VV 41' x 9' (Front -270) - -- 1 25.0 0.30 0.23 Insect Screen (default) Registration Number: 214-N0153178A-000000000-0000 Registration Date/rime: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xml CFI R=PRF-01 '- Page 4 of 8 DOORS 01 02 03 01 02 03 04 Name Side of Building Area (ft2) U -factor 3080 Fr/AI 41' x 9' 24.0 0.50 3068 Fr/W 41' x 9' 20.0 0.50 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R -value Assembly Layers Name Zone Area (ft2) 2x4 Top Chord of Edge Insul. R -value& Depth Cavity/ Frame: no insul. /2x4 Top Chrd Heated Exposed Whole House Roof Truss @ 24 in. 0.1 Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. none Roofing. Light Roof (Asphalt Shingle) None 0.8 No • Inside Finish: Gypsum Board • Cavity/Frame: R -15/2x4 R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board .:� ... Al Cavity / Frame: R-9.1 / 2x4 R-38 Roof Attic w/Radiant Ceilings (below attic) VWbod Framed Celmg y2x4 @ 24 in O C R 38 Over Floor Joists: R-28.9 insul. AN t, AI SLAB FLOORS �[v�., I .....::,..,:Mi£a,.-4m:`d • �g=, n e>.�.. .o v..S. "1Y. .w�—�aD=: 01 .. ... 02 03 04 0506 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated Exposed Whole House 1062 0.1 None 0.8 No Covered Whole House 710 0.1 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required -- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 1 .0% Registration Number: 214-N0153178A-000000000-0000 Registration Date/Time: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera) 120514.xmi CFIR-'PRF-01 Page 5 of 8 WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.65 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHWSys 1 - 1/1 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 Efficiency Heating System Cooling System Distribution Name Floor Area Name S stem Tr a y yp NameDuct d Name Ducted System Fan System Served 15 No No �_ system HVAC System) er OthHeaUCool k' Heating Compo ent 1 Yes Cooling Component) .� Yes Air Distribution 1772 System 1 .�Y HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 92.5 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.95 15 No No Cooling Component system 1 -hers -cool Registration Number: 214-No15317eA-000000000-0000 Registration Date/Time: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xml CF1 R:PRF-01 Page 6of8 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 06 06 07 08 IAQ Watts/CFM I Verified Duct Design Low -leakage Supply Duct Verification w Duct Leakage Target (%) Verified Duct Location Name Type Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in attic Specified Lower g Attic Attic None Air Distribution �9 c t. AR 1,510om.. Leakage Target System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 Name Duct Leakage IAQ Watts/CFM I Verified Duct Design Low -leakage Name Verification w Duct Leakage Target (%) Verified Duct Location Return Supply Air Handler K..i F Air Distribution SystemAM Re uired 3 6 0 Not Re uired q Not Required q Not Required q Required q 1 -hers -dist �9 c t. AR 1,510om.. HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Name IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification DwellingUnit 47.72 0.25 Default 0 Required Registration Number: 214-No153178A-000000000-0000 Registration Date/Time: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xmi CFI R -PRF -01 Page 7 of 8 Registration Number: 214-No153176A-000000000-0000 Registration Date/Time: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xm1 CFI R:PRF-01 Page 8of8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Santiago Lopez-Ocampo Company: Signature Date: Santiago Lopez-Ocampo 2015-01-2120:45:20 Address: CEA/HERS Certification Identification (If applicable): P.O. Box 1018 NA City/State/Zip: Phone: La Quinta, CA 92247 760 485 8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system. design features ident�ed,on this Certificate of Complianceare consistent.with the information provided on other applicable compliance documents, A� a worksheets, calculations, plans and Specifications submitted t' the enforcement agency for approval (with this building permit application. Responsible Designer Name: £ ,� Responsible Designer Signature r r Eduardo Escobar w _ f Company: Date Signed: Escobar Design 2015-01-22 13:02:16 Address: License: 43-927 Pacific Ave. NA City/State/Zip: Phone: Indio, CA 92201 760-289-9221 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-NO15317BA-000000000-0000 Registration Date/Time: 2015-01-22 13:02:16 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-05 10:27:45 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: FOREMOST HOMES INC. Calculation Date/Time: 10:25, Fri, Dec 05, 2014 Calculation Description: Title 24 Analysis Input File Name: Plan 1772 Garage Left [lot 21 Avenida Herrera] 120514.xml CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Santiago Lopez-Ocampo 41.0-� Company: Signature Date: Santiago Lopez-Ocampo 12/5/2014 Address: /HCEAERS Certification Identification (If applicable): P.O. Box 1018 city/staceeza Quinta, Ca 92247 Phone: 7��485.8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 that the energy features and specifications identified on this Certificate oo, Gc, mpliance to the Title 24, Part 1 Part 6 the California Code certify performance conform requirements of and of of Regulations. 3. The building design features or system design features identified on this Certificate of Comp lance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agencyor approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Company: Date Signed: ESCOBAR DESIGNS Address: License: 43927 Pacific Ave. City/State/zip: Phone: Indio, Ca 92201 760.289.9221 �A Registration Number: CA Building Energy Efficiency Stan a ds - 2013 Residential Compliance Registration Date/Time: Report Version - CFiR-10172014-651 HERS Provider: Report Generated at: 2014-12-05 10:27:06 MANDATORY MEASURES $UMMARY: `Residential (Page 1, of 3 MF -1 R Project Name Date FOREMOST HOMES INC. Plan 1772 GL 1121512014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (Cf -1 R, CF -IR -ADD, or Cr - 1R -ALT Form) shall supersede the items marked with an asterisk(*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelo elM.easXe ' 110.6(a)l: Doors and windows between conditioned and unconditioned Spaces are manufactured to limit.air leakage. §110.6(a)4: Fenestration products (except 'field -fabricated Wndows).haVe alabel listiba the certified Q -Factor, certified'Solar'Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111(a). 110.7: Exterior doors and windows are weather-stripped; all 'ants and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Maters I. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance Values 'of.the cool roofing material meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150.0(a): Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling or equivalent U -factor. 150.0(b): Loose fill insulation shall conform with. manufacturer's installed design labeled R -Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall (R-19 in 2x6) ore uivalent, U -factor. *§1 50.0 d : Minimum R-19 insulation in raised wood -frame, floor or equivalent U -factor. §150.0(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000)when specified on the CF -1R Form. §150.0(g): Mandatory Va2gr barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulatign material alone without facings is'no greater than 0.3%; water vapor permeance , rate is no rester than 2.0 perm/in and shall be rotected from.. sisal darria e�and VV light deterioration. §150.0(q) Fenestration'Products. Fenestration separating conditioned space frons unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)l : Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is greater, is exempt from, the maximum U -factor requirement. §150.0(r) Solar Ready Buildings. Shall meet the requirements of Section`11 0.16 applicable to the' building roect. ' Fireplaces, Decorative GasApplitincosand Gas Log Measures: 150.0 a 1A: Masonry or facto -built fireplaces have a closable metal or lass doproovering the entire o'enin 'of the firebox, §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area;and is equipped with a with a readil .accessible., operable, and ti ht-fittin 4 damee and or a combustion -air control device. . §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cootirig a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditipnirij,'Water.Heaffirig and Plumbing S stern Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve, and recirculation loo connection requirements of. 1.10.3(c)5.. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central fumaces, household cooking appliances, (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or.ACCA. §150.0(i): Heating systems are equipped ed with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)l A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 orreater. ' §150.00)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect. hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.3 by EnergySoft User Number. 5732 ID: LQ120514 L21 Page 11 of 14 MANDATORY. AI "SURES SU�VIMARY. A% ;' 'deh .iai. Page 2 :of .3 W -1.R , Project Name Date FOREMOST HOMES INC. Plan 1.772 GL 1121512014 §150.00)2A: All domestic hot water system piping conditions listed below; wFiether boned or unburied, mu§t`be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the beating source to. the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heatingsystems or hot water"systems >15 psi, meets the requirements of Standards Table 120.3-A. 150.00)3A: Insulation is.protected from.dama e, includin that due to.sunli lit, moisture, a ul ment.maihtenance, and.wind. §150.00)4: Solarwater=heating systems and/or collectors are ceFtified by the Solar,Rating and Certification":Corporotioh'. §150.0(m)l: All air -distribution system ducts and.pl'eriiirns installed :are sealed and insulated.to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5;: supply -air and cetum-air ducts and.pleriims are insulated to',.* minimum installed .- level of R-6 or enclosed entirely in conditioned space. .Openings shall be _sealed,with rnastic,:tape'or other duct -closure. system that,` ' 'requ'ire`ments meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the of UL723. tf mastic or to a is used to seal openings reater than 1/4 inch, the.combination df rrmastic antl either mesh or to e'shall tie used §150.0(m)l: Building cavities, suppoit platforms for air handlers, and plenums defined or constructed Wih,nlaterials othe-r'than Sealed sheet metal, duct board or flexible dud shall not be used #or conveying; condiponed air.Building cavities and support platforms may contain duds. Duds installed in cavities and support platforms `shall not be compressed to cause redudions inthe'cross=-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components.0hi tl.not'be "sealed witli cloth back rubber adhesive dud tapes' unless such tape is used in combination with mastic and draw bands..` 150.0(m)7: Exhaust fans stems have back draft or automdtic- day 'rs... §150.0(m)8: Gravity ventilating systems s6Mng conditioned space have'either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due,to.§uniight, rimo sture; equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with"a coating that is wate(:e&ardant and provides`shielding from solar radiation that can cause degradation of, the,material. §150.0(m)10: Flexible duds cannot have porous inner • res. §150.0(n)l : Systems using gas or propane watee heaters,-whethertank or on -demand, to serve individual dwelling units shall include all the following components: A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with.no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space'whe're the water' heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line,with,a,capacity of at least 200.,000 Btu/hr: §150.0(o): All dwelling units shall -meet the requirements of ANSI/A$HRAE Standard 62.2 Ventilation acid Acceptable.Indotir Air Quality in Low -Rise Residential Buildings. Window operation is not*" permissible method of'prov ding the Whole Building Ventilation required'in Section 4 of that Standard. Pool and Spa Heating System E ui merit 1Vleasures: §110.4(a): Any pool or spa heating"system shall be certified to have: a thermal efficiency that complies with the Apphance'l fficiency Regulations; an on-off switch mounted outside of.the heater;`'a permanent weatherproof plate orcard with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)l: Any pool or spa heating equipitieint shall be'installed 0th sifleast 36° of -pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar. heating. 110.4(b)2: Outdoor pools or spas. that have a,heat. um or gas heater shall have a cover, ._ :..• §110.4(b)3: Pools shall have directional inlets'that adeguateiy mix the`poof wafer; "and time switch that will allow all pumps to be set or' programmed to run onlyduringoff-peak electric demand eriods. §150.0(p): Residential popl.systems orequipment meet the pump. sizing, floW-rate, pjeihg, filters and valve re.. uirements of 150.0 Residential Lighting Measures: §150.0(k)1A: Installed luminaires''shall be classified as high=efficacy or_low=efficacy for compliance`with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1C: The wattage ofermanentl ' iristalled luminalres,itiall 6.e defdrr6inoO ass ecified b.'" 130.0(c). 150.0 k 1 D: Ballasts for fluorescent :lam s rated .13• Watts or greater shall be. electronic and, shall have a n.oUtput frog 066c..<--'20 kHz. . §150.0(k)l E: Permanently installed night lights and' night' lights.integral to installed luminaires orezhaustfans shall'be eafed to consume no more than five wafts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be contrplled.by vacancy sensors. . EnergyPro 6.3 by EnergySoft User;Number 6732 • .. •. :•' -::. ::..: 0: LQ126514 LV .Page 12 of 14_ MANDATORY MEASURE$ SUMMARY: ',Residential . Pa e:..3 of 3 ,.:: , MF-.1 R Project Name Date FOREMOST HOMES INC. Plan 1772 GL 12/5/2014 150.0 k 1 F: Lighting integral to exhaust fans, in rooms other than kitchens, shall.ineet the applicable r6: uirements of; .150.0(k. §150.0(k)2: All switching devices and controls shall meet.the re uirements of. 150:0 k 2.. .;. §150.0(k)3: A minimum of 50 percent of the total rated wattage of perman"irntly installed lighting in`kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50 percent high efficacy requirement when all, lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2,. and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal'to cabinets shall use nomorethan 20 wafts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following •requiremerits: A. A minimum of one high efficacy luminaire shall be installed inei h bathrborii ;and B. All other lighting installed, in,.each bathroom.shall be high efficac `.or contr'o1led.b vacant sensors.. ; ; •.. • :' §150.0(k)6: Lighting installed in'attached and detached garages,"iaundryrooms,"and utility rooms sh311 be high efficacy luminaires and controlled by vacancy sensors.. §150.0(k)7: Lighting installed in rooms or areas'other"than"in kitctiens, bathrooms, garages, laundry• rooms, arid'utilitj rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors:" EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1,000,.square feet located on,.a residential site. §150.0(k)8: Luminaires recessed into insulated ceitings`stiall be listed for zero clearance insulation contact (IC) by Underwriters,: Laboratories or other nationally recognized testing/rating laboratory; and have a label that cgrtifies the luminaire is;airtight'vi�th air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM 9283; and be sealed with a•gasket or caulk between the luminaire'housing and ceiling. §150.0(k)9A: For single -family residential buildings,-outdoor lighting permanently mounted to a residential building or other'buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of th.e following `requirements:' i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ' ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch' that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours, or c. Energy management control system which meets all of the following requirements:, At a minimum provides the functionality of an astronomical time clock in accordance with Section .110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMC.S in , .• Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically tum the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi-family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, M.2,130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports.with a, total of eight.or more vehicles per site shall comply with the applicable requirements in Sections 11.0.9130.0, 130.2 130.4, 140.7„and:141..0. ., §150.0(k)10: Internally illuminated address signs shall comply with'Section 140.8; OR not'contdin'a screw-base `socket; and consume no more than five watts of power as determined according to §13.0.0(d). _ §150.0(k)11: Lighting for residential parking garages for eight: or more' vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. §150.0(k)12A. In a low-rise multi-family residential building where the total interior co hm6n area..in d Single building equals"20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires •or' controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi-family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.3 by EnergySoR • User Number 5232 .: ;, . ; ' ,.. 10: LP120514 421 : Page 13, of 1.4 ,