13437 (SFD)Building
Address 52-811 Ave.Herrera
,
Owner David Killer
P.O. BOX 1504
78-105 CALLE ESTADO
LA QUINTA, CALIFORNIA 92253
Mailing P.O. Box 722
Address
City Zip 751
,a tuinta8 C.
Contractor
Pacific Trades
Addracc
City lZip I Tel.
State Lic. City
& Classif. B 425381 Lic. # 1955
Arch., Engr.,-
Designer
Address Tel.
City ( Zip ( State
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
* OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a -
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any 'violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided thatsuch improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
O 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption' you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives sof this city to enter the -above-.
mentioned property for inspection purposes.
Signature of applicant -Date-
Mailing
ateMailing Address
City, Stale, Zip
No. 1.3437
VN r3
UILDING: -TYPE CONST. OCC: GRP.
773-324-016
.P. Number
Lot 3 Block 159
egal Description
SFD
roject Description
Sq. Ft. No. No. Dw.
Size Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Permit doe -63 not include block €walls
or pool.
Estimated Valuation $39,249.00
PERMIT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
.S.M.I.
Grading
Driveway Enc.
Infrastructure
Precise Plan
TOTAL
REMARKS
AMOUNT
.vv
ew
6.l/.7t
594.511
4 yI25. Sry:
150.0{
8.9;
20.01
.01
18969.8.
75
.49 3,2U I
_ 1
ZONE: BY: v
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line_
Side Street Setback from Center Line
Side Setback from Property Line_
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SQ. FT. ® $
UNITS
SLAB GRADE
ROUGH PLUMB.
BONDING
YARD SPKLR SYSTEM
2ND FL. SQ. FT.
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
MOBILEHOME SVC.
BAR SINK
POR. SQ. FT. ®
GAS (ROUGH) Jb�
!
METER LOOP
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
GAS (FINAL)
TEMP. POLE
DRAINAGE PIPING
CAR P. SQ. FT. @
GROUT
WATER HEATER
WALL SO. FT. ®
-
DRINKING FOUNTAIN
BOND BEAM
WATER SYSTEM
FINAL INSP. /0�'7�G/
♦ (
URINAL
SQ. FT. ®
_$
LUMBER GR.
ESTIMATED CONSTRUCTION VALUATION $
ROOFING 57—Z" �7 �'✓
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
VENTILATION
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ® c
BATH TUB
SO. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11A c
SEWAGE DISPOSAL
SQ.FT.GAR ® 3/ac
HOUSE SEWER
FINAL INSPECTION t'� C1 4r(
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBINGS -s�/�I
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH) Jb�
!
METER LOOP
HEATING (FINAL)
OTHER APPJEQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
FINAL INSP. /0�'7�G/
♦ (
FINAL INSP. Q q
GRADING
,(-'Ji—cu. yd.
$ plus x$
_$
LUMBER GR.
FRAMING s_v1y�A
ROOFING 57—Z" �7 �'✓
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL�l�(/ Ln
LATHING y 6.0
MESH
INSULATION/SOUNDS
FINISH GRADING
FINAL INSPECTION t'� C1 4r(
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURES/INITIALS
GARDEN WALL FINAL
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201
Document Cannot Be Duplicated 619-775-3500
Date 4/29/94 Type of Permit I La Quinta
No. 112799 Permit #
Log
Owner Name Miller, David
No. 52-811 Street Avenue Herrera
City La Quinta Zip 92253 Study Area
APN # 773-324-016 1 Tract # I J Lot # 0 Square Footage 11499
Type of Development Single Family Residence I No. of units 0
Comments
At the present time, the Desert Sands Unified School District does not collect fees on
garages/ carports, covered patios /walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of 1.65 x 1499 or $ 2,473.35 have been paid to D.S.U.S.D. for
the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued.
Fees Paid By David Miller Telephone
Name on the check
By Dolores A. Ballesteros
Superintendent ✓4� r ;
Fee collected /exempted by Peggy Reyes
Payment Received rn.
Signature &AU Check -No. 4102~
r�
P
Collector: Attach a copy of county or city plan check application form to district copy for all waivETS:
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
Received F
Address:
Account N
Service Ad
Meter(s)
Service(s)
❑ Backflow(s)
❑ House Lateral(s)
❑ Detector Check(s)
❑ Meter Surcharge
anitation Capacity Charge
�
W.S.B.F.C.
❑ Temporary Construction Meter
❑ Turn on Charge
❑ Uncollected Account - Name
❑ Inspection Fee -Tract -
Fee -
❑ Plan Check Fees Water / Sewer -
Tract -
❑ Bond Payment - A.D. - Bond
Assmt.
❑ Customer Deposit
❑ Other
COACHELLA VALLEY WATER DISTRICT
recu Or -I MOT nrTAll
Remarks:
TOTAL $ 424` 5:7.1�� )
Water Service
i
Cashier T
CVWD-438 (11189)
9
0
010
4
�7
OF
of
�4
This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building
F',
Code certifying that at the time of issuance this' structure was in compliance with the various
ordinances -of the City*regulating building construction or use. 'For the following:
BUILDING ADDRESS 52-811 Avenida Herrera
F
T
Use Classification Single Family Dwelling EUdg. Permit No. 13437
ro
G up R3 Type Construction VN Fire Zone Use Zone SR
David Ross Miller P.O. Box 722
Owner of Building Address
City La Quinta, CA 92253
BY: I-onnie Day
Date: October 7, 1994
Building Official POST IN A CONSVICUOU3 PLACE
TABLE OF CONTENTS TOC
Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94
Project Address ........ �-JL- t4 t �L& u 0t - ---------------------
LA QUINTA
Documentation Author ... W J FINNELL Building Permit #
Company ................ Finnell
Telephone .............. 909-659-3961 Plan Check / Date
Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone ........... 15 ---------------------
MICROPAS4 v4.02 File-1499SQFT Wth-CTZ15S92 Program -TOC
User#-MP1325 User-Finnell Run-1499SQFT
-------------------------------------------------------------------------------
TABLE OF CONTENTS
-----------------
Report Page
FORM CF -1R ................ I
FORM MF -1R ................ 4
FORM C -2R ................. 6
0
FORM C -3R ................. 9
HVAC SIZING ............... 11
0
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page I CF -1R
Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94
Project Address ........ ---------------------
LA QUINTA
Documentation Author ... W J FINNELL Building Permit #
Company ................ Finnell
Telephone .............. 909-659-3961 Plan Check / Date
Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone ........... 15 ---------------------
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
GENERAL INFORMATION
Conditioned Floor Area ..... 1499 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units ... 1
Number of Stories .......... 1
Floor Construction Type .... Slab On Grade (Package D)
BUILDING SHELL INSULATION
Component
Insulation
Assembly
Yes
Type
R -value
U -Value
Location/Comments
-------------
Wall
----------
R-13
--------
0.063
----------------------------------------
Roof
R-38
0.025
Attic
Door
R-0
0.330
Solid Wood
SlabEdge
R-0
0.900
To Outside
SlabEdge
R-0
0.720
To Outside
SlabEdge
R-0
0.500
To Garage
FENESTRATION
Type
------------ --------------
Exposed
SlabOnGrade
Yes
# of
Interior
InteriorHorz
Over -
Area U_
Pan-
Shading/
Exterior
hang/
Framing
Orientation
(sf) Value
es
Description
Shading
Fins
Type
-------------------
----- J -----
----
---------------
-----------
----
---------
Window
Front
(E)
17.5/0.870
2
Drapes.Std
None
None
Metal
Window
Left
(5)
28-.O/�P(.870
2
Drapes.Std
None
None
Metal
Window
Back
(W)
B9.3 0.870
2
Drapes.Std
None
None
Metal
Window
Right
(N)
42.5t'10.870
2
Drapes.Std
None
None
Metal
Type
------------ --------------
Exposed
SlabOnGrade
Yes
SlabOnGrade
No
InteriorHorz
Yes
THERMAL MASS
------------
Area Thickness
(sf) (in)
------ ---------
398 3.5
1101 3.5
26 1.0
Location/Comments
------------------------
TILE
CARPET
COUNTER TOP
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
Equipment Type
---------------
Furnace
ACSplit
HVAC SYSTEMS
------------
Minimum Duct
Efficiency Location
------------ -------------
0.780 AFUE Attic
10.50 SEER Attic
.Duct, Thermostat
R -value Type
------- ------------
R-4.2 Setback
R-4.2 Setback
WATER HEATING SYSTEMS
---------------------
Number
in Energy
Tank Type Heater Type Distribution Type System F,actor
------------ ----------- ------------------- --- w ---- --------
Water Heater to meet minimum CEC Standards
SPECIAL FEATURES/REMARKS
------------------------
Tank
External
Size
Insulation
(gal)
------
R -value
----------
'CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
--------------------
This certificate of compli , ance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section.
DESIGNER or OWNER
Name .... DAVE MILLER
Company. PACIFIC TRADES
Address. 53430 AVE CARRANZA
LA QUINTA,A CA
Phone ... 619-342-8363
License. rJ20
Signed.. 'Zor,
ENFORCEMENT AGENCY
Name ....
Title ...
Agency..
Phone ...
Signed.
(date)
DOCUMENTATION AUTHOR
Name .... W J FINNELL
Company. Finnell
Address. 61880 INDIAN HILL RD #34F
MTN CENTER, CA 92561
Phone ... 909-659-3961
Signed.
(dateo f
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -IR
Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94
Project Address ........ ----------------------
LA QUINTA
Documentation Author ... W J FINNELL Building Permit #
Company ................ Finnell
Telephone .............. 909-659-3961 Plan Check / Date
Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone ........... 15 ---------------------
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM MF -IR
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
Design- Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturers labeled R -Value.
*150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
*150(d): Minimum R-13 raised floor insulation in framed floors;
minimum R-8 in concrete raised floors.
150(i): Slab edge insulation - water absorption rate no greater
than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.
11e: Insulation specified or installed meets CEC quality
standards. Indicate type and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
exfiltration controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label with
certified U -value, and infiltration certification.
c. Exterior doors and windows weather-stripped; all joints
and penetrations caulked and sealed.
150(g): Vapor barriers mandatory in Climate Zones 14 and 16
.only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets CEC quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and gas logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -IR
Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM MF -1R
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
--------------------------------------------------------------
Design- Enforce-
er ment
110-13: HVAC equipment, water heaters, showerheads and faucets
certified by the CEC.
150(i): Setback thermostat on all applicable heating systems.
150(j): Pipe and Tank insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or
backup solar hot water tanks) have insulation blanket (R-12
or greater) or combined interior/exterior insulation (R-16
or greater).
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. All buried or exposed piping -insulated in recirculating
sections of hot water system.
4. Cooling system piping below 55 degrees insulated.
5. Piping insulat%d between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC
sections 1002 and 1004; ducts insulated to a minimum
installed value of R-4.2 or ducts enclosed entirely within
conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily access.ible, manually
operated dampers.
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System installed with:
a. At least 36 inches pipe between filter and heater for
future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnace, pool heater, spa heater or
household cooking appliance have no continuously burning
pilot light (Exception: Non -electrical cooking appliance
with pilot < 150 Btu/hr.).
LIGHTING MEASURES
-----------------
Design- Enforce-
er ment
150(k): 40 lumens/watt or greater for general lighting in
kitchens and rooms with water closets; and recessed ceiling
fixtures IC (insulation cover) approved.
COMPUTER METHOD SUMMARY Page 6 C -2R
Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94
Project Address ........ ---------------------
LA QUINTA
Documentation Author ... W J FINNELL Building Permit #
Company ................ Finnell
Telephone .............. 909-659-3961
Plan Check / Date
Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone ........... 15 ---------------------
MICROPAS4 v4.02 File-14?9SOFT Wth-CTZ15S92 Program -FORM C -2R
User#-MP1325 User-Finnell Run-1499SOFT
--------------------------------------------- m ----------------------------------
MICROPAS4 ENERGY USE SUMMARY
----------------------------
Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
----------------------- ----------
Design
Design
----------
Margin
----------
Space Heating ..........
3.56
3.15
0.41
Space Cooling ..........
34.60
33.99
0.61
Water Heating ..........
14.19
14.19
0.00
Total
--------
52.35
--------
51.33
--------
1.02
Building complies
with Computer Performance
GENERAL INFORMATION
-------------------
Conditioned Floor Area .....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units ...
Number of Building Stories.
Weather Data Type ..........
Floor Construction Type ....
Number of Building Zones ...
Conditioned Volume .........
Footprint Area .............
Ground Floor Area ..........
Slab -On -Grade Area .........
Glazing Percentage ..........
Average Ceiling Height .....
1499 sf
Single Family
New
Front Facing
1
1
ReducedYear
Detached
90 deg (E)
Slab On Grade (Package D)
1
13566 cf
1499 sf
1499 sf
1499 sf
11.8 % of FA
9.1 ft
COMPUTER METHOD
SUMMARY
F2
Insul
Page
7 C -2R
Project Title ..........
. 1499.DAVE
MILLER
R-val
-------
Date
........ 03/31/94
MICROPAS4
v4.02
File-1499SOFT Wth-CTZ15S92
Program -FORM
C -2R
-------------------------------------------------------------------------------
User#-MP1325
28
User-Finnell
Run-1499SQFT
No
To Outside
10 SlabEdge
BUILDING ZONE
INFORMATION
R-0
No
To Outside
Floor
-------------------------
# of
R-0
No
Vent Special
Area
Volume
Dwell
Cond-
Thermostat
Height Vent Area
Zone Type
(sf)
(cf)
Units
itioned
-------
Type
------------
(ft) (sf)
------ ---------
--------------
HOUSE
---------
---------
-----
Drapes.Std
2 Window
28.0
Residence
1499
13566
1.00
Yes
Setback
2.0 n/a
0.78
Drapes.Std
OPAQUE SURFACES
89.3
2
Metal
Area
---------------
U_ Insul
Act
Solar
Form 3
Location/
Surface
--------------
(sf)
value R-val
Azm Tilt Gains
Reference
Comments
HOUSE
------
----- -----
--- ----
-----
------------
----------------
1 Wall
101
0.063 R-13
90
90 Yes
W/13/2X4/16P
2 Wall
181
0.063 R-13
90
90 No
W/13/2X4/16P
3 Wall
473
0.063 R-13
180
90 Yes
W/13/2X4/16P
4 Wall
255
0.063 R-13
270
90 Yes
W/13/2X4/16P
5 Wall
459
0.063 R-13
0
90 Yes
W/13/2X4/16P
6 Roof
1499
0.025 R-38
0
0 Yes
R.38.2X4.24
Attic
7 Door
20
0.330 R-0
90
90 Yes
None
Solid Wood
8 Door
9
0.330 R-0
90
90 No
None
Solid Wood
PERIMETER LOSSES
FENESTRATION SURFACES
Length
F2
Insul
Solar
Surface
------------
(ft)
------
Factor
--------
R-val
-------
Gains
-----
Location/Comments
----------------------
HOUSE
Pan-
Frame
Open
U_
Act
9 SlabEdge
28
0.900
R-0
No
To Outside
10 SlabEdge
201
0.720
R-0
No
To Outside
11 SlabEdge
20
0.500
R-0
No
To Garage
FENESTRATION SURFACES
#.of
Vent
Sc
SC
Interior
Area
Pan-
Frame
Open
U_
Act
Glass
Int
Shading/
Surface
-----------
(sf)
es
Type
---------
Type
value
-----
Azm
---
Tlt
---
Only
----
Shade
----
Description
---------------
HOUSE
-----
----
------
1 Window
17.5
2
Metal
Slider
0.870
90
90
0.88
0.78
Drapes.Std
2 Window
28.0
2
Metal
Slider
0.870
ieo
90
0.88
0.78
Drapes.Std
3 Window
89.3
2
Metal
Slider
0.870
270
90
0.88
0.78
Drapes.Std
4 Window
42.5
2
Metal
Slider
0.870
0
90
0.88
0.78
Drapes.Std
COMPUTER METHOD SUMMARY Page B C -2R
Project Title .......... . 1499.DAYE MILLER Date ........ 03/31/94
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM C -2R
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
THERMAL MASS
Area
Thick Heat Conduct- Surface
Mass Type (sf)
(in)
Cap ivity R -value
Location/Comments
--------------- ------
HOUSE
-----
----- -------- --------
--------------------------
I SlabOnGrade 398
3.5
2B.0 0.98 R-0.0
TILE
2 SlabOnGrade 1101
3.5
28.0 0.98 R-2.0
CARPET
3 InteriorHorz 26
1.0
24.0 0.67 R-0.0
COUNTER
TOP
HVAC SYSTEMS
------------
Minimum Duct
Duct
Duct
System Type
----------------
Efficiency Location
R -value
Efficiency
HOUSE
------------
-------------
-------
----------
Furnace
0.780 AFUE Attic
R-4.2
0.830
ACSplit
10.50 SEER Attic
R-4.2
0.810
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R -value
------------ ----------- ------------------- ------ -------- ------ ----------
Water Heater to meet minimum CEC Standards
SPECIAL FEATURES/REMARKS
------------------------
E
CONSTRUCTION ASSEMBLY Page 9 3R
Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM 3R
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
I I
---------------------- 7 ----------
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Reference Name . W/13/2X4/16P
Description .... Wall R-13 2x4 16oc
Type ........... Wall
R -Value ........ 13 sf-F/Btuh
Framing
Material ..... FIR.2X4
Spacing ...... 16 inches on center
Fraction ..... 0.15
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
------------------- ------------------- ----------------
U-Value: (1 18.42 x 0.85) + (1 8.89 x 0.15) = 0.063 Btuh/sf-F
Total R -Value: 1 0.063 = 15.87 sf-F/Btuh
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
-------------
FILM.EX
----------------------------------------
Exterior air film: winter value
---------
0.17
---------
0.17
1.
STUCCO.O.25
0.25 in stucco
0.06
0.06
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
STYRENE.1.00
1.00 in polystyrene
4.00
4.00
4c.
BATT.R13
R-13 batt insul (cavity = 3.5 in)
13.00
4f.
FIR.2X4
2x4 in fir framing
3.46
5.
GYP.O.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
---------
0.68
Total Unadjusted R -Values
18.42
---------
G.B9
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
------------------- ------------------- ----------------
U-Value: (1 18.42 x 0.85) + (1 8.89 x 0.15) = 0.063 Btuh/sf-F
Total R -Value: 1 0.063 = 15.87 sf-F/Btuh
CONSTRUCTION ASSEMBLY Page 10 3R
Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94
MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM 3R
User#-MP1325 User-Finnell Run-1499SOFT
-------------------------------------------------------------------------------
---------------------------------
---------------------------------
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Reference Name . R.38.2X4.24
Description .... Roof R-38 2x4 24oc
Type ........... Roof
R -Value ........ 38 sf-F/Btuh
Framing
Material ..... FIR.2X4
Spacing ...... 24 inches on center
Fraction ..... 0.07
Material Cavity Frame
Name Description R -Value R -Value
------------- ---------------------------------------- --------- ---------
0. FILM.EX Exterior air film: winter value 0.17 0.17
1. SHNGL.ASPHLT Asphault shingle roofing 0.44 0.44
2. BLDG.PAPER Building paper (felt) 0.06 0.06
3. PLY.O.50 0.50 in plywood 0.62 0.62
4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 O�
5. BATT.R27.0 R-27 batt insulation 27.00 7:0)'
6c. BATT.R11.0 R-11 batt insul (cavity > 3.5,in) 11.00
6f. FIR.2X4 2x4 in fir framing .46
7. GYP.O.50 0.50 in gypsum or plaster board 0.45 0.45
1. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61
--------- ---------
Total Unadjusted R -Values 41.15
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
------------------- ------------------- -----
U-Value: (1 41.15 x 0.93) + (I 3'S�.2 x 0.07) 0.02�5 Btuh/sf-F
Total R -Value: 0 0104 1 0.025 40.51 sf-F/ tuh
a -2,
\�\J-V\ � W W"'I'
HVAC SIZING Page 11 HVAC
Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94
Project Address ........ ---------------------
LA DUINTA 11
Documentation Author ... W J FINNELL Building Permit #
Company ................ Finnell
Telephone .............. 909-659-3961 Plan Check Date
Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone ........... 15 ---------------------
MICROPAS4 v4.02 File-1499SQFT Wth-CTZ15S92 Program -HVAC SIZING
User#-MP1325 User-Finnell Run-1499SQFT
-------------------------------------------------------------------------------
GENERAL INFORMATION
Floor Area ................. 1499 sf
Volume ..................... 13566 cf
Front Orientation .......... Front Facing 90 deg (E)
Sizing Location ............ INDIO
Latitude ................... 33.7 degrees
Winter Outside Design ...... 29 F
Winter Inside Design ....... 70 F
Summer Outside Design ...... 112 F
Summer Inside Design ....... 78 F
Summer Range ............... 30 F
Interior Shading Used ...... No
Exterior Shading Used ...... No
Overhang Shading Used ...... No
Latent Load Fraction ....... 0.20
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Heating Cooling
Description (Btuh) (Btuh)
--------------------------------- ----------- -----------
Opaque Conduction and Solar ......
13088
5165
Glazing Conduction ...............
6324
5245
Glazing Solar ....................
n/a
7149
Infiltration ......................
7999
4741
Internal Gain ....................
n/a
2550
Ducts ............................
2741
24e5
Sensible Load ....................
Latent Load ......................
Minimum Total Load
30152
n/a
27334
5467
30152 32801
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.