Loading...
13437 (SFD)Building Address 52-811 Ave.Herrera , Owner David Killer P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 Mailing P.O. Box 722 Address City Zip 751 ,a tuinta8 C. Contractor Pacific Trades Addracc City lZip I Tel. State Lic. City & Classif. B 425381 Lic. # 1955 Arch., Engr.,- Designer Address Tel. City ( Zip ( State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE * OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a - permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any 'violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided thatsuch improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption' you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives sof this city to enter the -above-. mentioned property for inspection purposes. Signature of applicant -Date- Mailing ateMailing Address City, Stale, Zip No. 1.3437 VN r3 UILDING: -TYPE CONST. OCC: GRP. 773-324-016 .P. Number Lot 3 Block 159 egal Description SFD roject Description Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Permit doe -63 not include block €walls or pool. Estimated Valuation $39,249.00 PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing .S.M.I. Grading Driveway Enc. Infrastructure Precise Plan TOTAL REMARKS AMOUNT .vv ew 6.l/.7t 594.511 4 yI25. Sry: 150.0{ 8.9; 20.01 .01 18969.8. 75 .49 3,2U I _ 1 ZONE: BY: v Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line_ Side Street Setback from Center Line Side Setback from Property Line_ FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ UNITS SLAB GRADE ROUGH PLUMB. BONDING YARD SPKLR SYSTEM 2ND FL. SQ. FT. FORMS SEWER OR SEPTIC TANK ROUGH WIRING MOBILEHOME SVC. BAR SINK POR. SQ. FT. ® GAS (ROUGH) Jb� ! METER LOOP GAR. SO. FT. ® POWER OUTLET ROOF DRAINS GAS (FINAL) TEMP. POLE DRAINAGE PIPING CAR P. SQ. FT. @ GROUT WATER HEATER WALL SO. FT. ® - DRINKING FOUNTAIN BOND BEAM WATER SYSTEM FINAL INSP. /0�'7�G/ ♦ ( URINAL SQ. FT. ® _$ LUMBER GR. ESTIMATED CONSTRUCTION VALUATION $ ROOFING 57—Z" �7 �'✓ WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES VENTILATION WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11A c SEWAGE DISPOSAL SQ.FT.GAR ® 3/ac HOUSE SEWER FINAL INSPECTION t'� C1 4r( GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBINGS -s�/�I UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) Jb� ! METER LOOP HEATING (FINAL) OTHER APPJEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM FINAL INSP. /0�'7�G/ ♦ ( FINAL INSP. Q q GRADING ,(-'Ji—cu. yd. $ plus x$ _$ LUMBER GR. FRAMING s_v1y�A ROOFING 57—Z" �7 �'✓ REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL�l�(/ Ln LATHING y 6.0 MESH INSULATION/SOUNDS FINISH GRADING FINAL INSPECTION t'� C1 4r( CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date 4/29/94 Type of Permit I La Quinta No. 112799 Permit # Log Owner Name Miller, David No. 52-811 Street Avenue Herrera City La Quinta Zip 92253 Study Area APN # 773-324-016 1 Tract # I J Lot # 0 Square Footage 11499 Type of Development Single Family Residence I No. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/ carports, covered patios /walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.65 x 1499 or $ 2,473.35 have been paid to D.S.U.S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By David Miller Telephone Name on the check By Dolores A. Ballesteros Superintendent ✓4� r ; Fee collected /exempted by Peggy Reyes Payment Received rn. Signature &AU Check -No. 4102~ r� P Collector: Attach a copy of county or city plan check application form to district copy for all waivETS: Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting Received F Address: Account N Service Ad Meter(s) Service(s) ❑ Backflow(s) ❑ House Lateral(s) ❑ Detector Check(s) ❑ Meter Surcharge anitation Capacity Charge � W.S.B.F.C. ❑ Temporary Construction Meter ❑ Turn on Charge ❑ Uncollected Account - Name ❑ Inspection Fee -Tract - Fee - ❑ Plan Check Fees Water / Sewer - Tract - ❑ Bond Payment - A.D. - Bond Assmt. ❑ Customer Deposit ❑ Other COACHELLA VALLEY WATER DISTRICT recu Or -I MOT nrTAll Remarks: TOTAL $ 424` 5:7.1�� ) Water Service i Cashier T CVWD-438 (11189) 9 0 010 4 �7 OF of �4 This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building F', Code certifying that at the time of issuance this' structure was in compliance with the various ordinances -of the City*regulating building construction or use. 'For the following: BUILDING ADDRESS 52-811 Avenida Herrera F T Use Classification Single Family Dwelling EUdg. Permit No. 13437 ro G up R3 Type Construction VN Fire Zone Use Zone SR David Ross Miller P.O. Box 722 Owner of Building Address City La Quinta, CA 92253 BY: I-onnie Day Date: October 7, 1994 Building Official POST IN A CONSVICUOU3 PLACE TABLE OF CONTENTS TOC Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94 Project Address ........ �-JL- t4 t �L& u 0t - --------------------- LA QUINTA Documentation Author ... W J FINNELL Building Permit # Company ................ Finnell Telephone .............. 909-659-3961 Plan Check / Date Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone ........... 15 --------------------- MICROPAS4 v4.02 File-1499SQFT Wth-CTZ15S92 Program -TOC User#-MP1325 User-Finnell Run-1499SQFT ------------------------------------------------------------------------------- TABLE OF CONTENTS ----------------- Report Page FORM CF -1R ................ I FORM MF -1R ................ 4 FORM C -2R ................. 6 0 FORM C -3R ................. 9 HVAC SIZING ............... 11 0 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page I CF -1R Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94 Project Address ........ --------------------- LA QUINTA Documentation Author ... W J FINNELL Building Permit # Company ................ Finnell Telephone .............. 909-659-3961 Plan Check / Date Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone ........... 15 --------------------- MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM CF -1R User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area ..... 1499 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units ... 1 Number of Stories .......... 1 Floor Construction Type .... Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly Yes Type R -value U -Value Location/Comments ------------- Wall ---------- R-13 -------- 0.063 ---------------------------------------- Roof R-38 0.025 Attic Door R-0 0.330 Solid Wood SlabEdge R-0 0.900 To Outside SlabEdge R-0 0.720 To Outside SlabEdge R-0 0.500 To Garage FENESTRATION Type ------------ -------------- Exposed SlabOnGrade Yes # of Interior InteriorHorz Over - Area U_ Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type ------------------- ----- J ----- ---- --------------- ----------- ---- --------- Window Front (E) 17.5/0.870 2 Drapes.Std None None Metal Window Left (5) 28-.O/�P(.870 2 Drapes.Std None None Metal Window Back (W) B9.3 0.870 2 Drapes.Std None None Metal Window Right (N) 42.5t'10.870 2 Drapes.Std None None Metal Type ------------ -------------- Exposed SlabOnGrade Yes SlabOnGrade No InteriorHorz Yes THERMAL MASS ------------ Area Thickness (sf) (in) ------ --------- 398 3.5 1101 3.5 26 1.0 Location/Comments ------------------------ TILE CARPET COUNTER TOP CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94 MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM CF -1R User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- Equipment Type --------------- Furnace ACSplit HVAC SYSTEMS ------------ Minimum Duct Efficiency Location ------------ ------------- 0.780 AFUE Attic 10.50 SEER Attic .Duct, Thermostat R -value Type ------- ------------ R-4.2 Setback R-4.2 Setback WATER HEATING SYSTEMS --------------------- Number in Energy Tank Type Heater Type Distribution Type System F,actor ------------ ----------- ------------------- --- w ---- -------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS ------------------------ Tank External Size Insulation (gal) ------ R -value ---------- 'CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94 MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM CF -1R User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compli , ance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name .... DAVE MILLER Company. PACIFIC TRADES Address. 53430 AVE CARRANZA LA QUINTA,A CA Phone ... 619-342-8363 License. rJ20 Signed.. 'Zor, ENFORCEMENT AGENCY Name .... Title ... Agency.. Phone ... Signed. (date) DOCUMENTATION AUTHOR Name .... W J FINNELL Company. Finnell Address. 61880 INDIAN HILL RD #34F MTN CENTER, CA 92561 Phone ... 909-659-3961 Signed. (dateo f MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -IR Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94 Project Address ........ ---------------------- LA QUINTA Documentation Author ... W J FINNELL Building Permit # Company ................ Finnell Telephone .............. 909-659-3961 Plan Check / Date Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone ........... 15 --------------------- MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM MF -IR User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 11e: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 .only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -IR Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94 MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM MF -1R User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(i): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping -insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulat%d between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily access.ible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES ----------------- Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY Page 6 C -2R Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94 Project Address ........ --------------------- LA QUINTA Documentation Author ... W J FINNELL Building Permit # Company ................ Finnell Telephone .............. 909-659-3961 Plan Check / Date Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone ........... 15 --------------------- MICROPAS4 v4.02 File-14?9SOFT Wth-CTZ15S92 Program -FORM C -2R User#-MP1325 User-Finnell Run-1499SOFT --------------------------------------------- m ---------------------------------- MICROPAS4 ENERGY USE SUMMARY ---------------------------- Energy Use Standard Proposed Compliance (kBtu/sf-yr) ----------------------- ---------- Design Design ---------- Margin ---------- Space Heating .......... 3.56 3.15 0.41 Space Cooling .......... 34.60 33.99 0.61 Water Heating .......... 14.19 14.19 0.00 Total -------- 52.35 -------- 51.33 -------- 1.02 Building complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area ..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units ... Number of Building Stories. Weather Data Type .......... Floor Construction Type .... Number of Building Zones ... Conditioned Volume ......... Footprint Area ............. Ground Floor Area .......... Slab -On -Grade Area ......... Glazing Percentage .......... Average Ceiling Height ..... 1499 sf Single Family New Front Facing 1 1 ReducedYear Detached 90 deg (E) Slab On Grade (Package D) 1 13566 cf 1499 sf 1499 sf 1499 sf 11.8 % of FA 9.1 ft COMPUTER METHOD SUMMARY F2 Insul Page 7 C -2R Project Title .......... . 1499.DAVE MILLER R-val ------- Date ........ 03/31/94 MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM C -2R ------------------------------------------------------------------------------- User#-MP1325 28 User-Finnell Run-1499SQFT No To Outside 10 SlabEdge BUILDING ZONE INFORMATION R-0 No To Outside Floor ------------------------- # of R-0 No Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned ------- Type ------------ (ft) (sf) ------ --------- -------------- HOUSE --------- --------- ----- Drapes.Std 2 Window 28.0 Residence 1499 13566 1.00 Yes Setback 2.0 n/a 0.78 Drapes.Std OPAQUE SURFACES 89.3 2 Metal Area --------------- U_ Insul Act Solar Form 3 Location/ Surface -------------- (sf) value R-val Azm Tilt Gains Reference Comments HOUSE ------ ----- ----- --- ---- ----- ------------ ---------------- 1 Wall 101 0.063 R-13 90 90 Yes W/13/2X4/16P 2 Wall 181 0.063 R-13 90 90 No W/13/2X4/16P 3 Wall 473 0.063 R-13 180 90 Yes W/13/2X4/16P 4 Wall 255 0.063 R-13 270 90 Yes W/13/2X4/16P 5 Wall 459 0.063 R-13 0 90 Yes W/13/2X4/16P 6 Roof 1499 0.025 R-38 0 0 Yes R.38.2X4.24 Attic 7 Door 20 0.330 R-0 90 90 Yes None Solid Wood 8 Door 9 0.330 R-0 90 90 No None Solid Wood PERIMETER LOSSES FENESTRATION SURFACES Length F2 Insul Solar Surface ------------ (ft) ------ Factor -------- R-val ------- Gains ----- Location/Comments ---------------------- HOUSE Pan- Frame Open U_ Act 9 SlabEdge 28 0.900 R-0 No To Outside 10 SlabEdge 201 0.720 R-0 No To Outside 11 SlabEdge 20 0.500 R-0 No To Garage FENESTRATION SURFACES #.of Vent Sc SC Interior Area Pan- Frame Open U_ Act Glass Int Shading/ Surface ----------- (sf) es Type --------- Type value ----- Azm --- Tlt --- Only ---- Shade ---- Description --------------- HOUSE ----- ---- ------ 1 Window 17.5 2 Metal Slider 0.870 90 90 0.88 0.78 Drapes.Std 2 Window 28.0 2 Metal Slider 0.870 ieo 90 0.88 0.78 Drapes.Std 3 Window 89.3 2 Metal Slider 0.870 270 90 0.88 0.78 Drapes.Std 4 Window 42.5 2 Metal Slider 0.870 0 90 0.88 0.78 Drapes.Std COMPUTER METHOD SUMMARY Page B C -2R Project Title .......... . 1499.DAYE MILLER Date ........ 03/31/94 MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM C -2R User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments --------------- ------ HOUSE ----- ----- -------- -------- -------------------------- I SlabOnGrade 398 3.5 2B.0 0.98 R-0.0 TILE 2 SlabOnGrade 1101 3.5 28.0 0.98 R-2.0 CARPET 3 InteriorHorz 26 1.0 24.0 0.67 R-0.0 COUNTER TOP HVAC SYSTEMS ------------ Minimum Duct Duct Duct System Type ---------------- Efficiency Location R -value Efficiency HOUSE ------------ ------------- ------- ---------- Furnace 0.780 AFUE Attic R-4.2 0.830 ACSplit 10.50 SEER Attic R-4.2 0.810 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- ------------------- ------ -------- ------ ---------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS ------------------------ E CONSTRUCTION ASSEMBLY Page 9 3R Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94 MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM 3R User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- I I ---------------------- 7 ---------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Reference Name . W/13/2X4/16P Description .... Wall R-13 2x4 16oc Type ........... Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------- ------------------- ---------------- U-Value: (1 18.42 x 0.85) + (1 8.89 x 0.15) = 0.063 Btuh/sf-F Total R -Value: 1 0.063 = 15.87 sf-F/Btuh Material Cavity Frame Name Description R -Value R -Value 0. ------------- FILM.EX ---------------------------------------- Exterior air film: winter value --------- 0.17 --------- 0.17 1. STUCCO.O.25 0.25 in stucco 0.06 0.06 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. STYRENE.1.00 1.00 in polystyrene 4.00 4.00 4c. BATT.R13 R-13 batt insul (cavity = 3.5 in) 13.00 4f. FIR.2X4 2x4 in fir framing 3.46 5. GYP.O.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 --------- 0.68 Total Unadjusted R -Values 18.42 --------- G.B9 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------- ------------------- ---------------- U-Value: (1 18.42 x 0.85) + (1 8.89 x 0.15) = 0.063 Btuh/sf-F Total R -Value: 1 0.063 = 15.87 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 10 3R Project Title .......... 1499.DAVE MILLER Date ........ 03/31/94 MICROPAS4 v4.02 File-1499SOFT Wth-CTZ15S92 Program -FORM 3R User#-MP1325 User-Finnell Run-1499SOFT ------------------------------------------------------------------------------- --------------------------------- --------------------------------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Reference Name . R.38.2X4.24 Description .... Roof R-38 2x4 24oc Type ........... Roof R -Value ........ 38 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction ..... 0.07 Material Cavity Frame Name Description R -Value R -Value ------------- ---------------------------------------- --------- --------- 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.ASPHLT Asphault shingle roofing 0.44 0.44 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. PLY.O.50 0.50 in plywood 0.62 0.62 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 O� 5. BATT.R27.0 R-27 batt insulation 27.00 7:0)' 6c. BATT.R11.0 R-11 batt insul (cavity > 3.5,in) 11.00 6f. FIR.2X4 2x4 in fir framing .46 7. GYP.O.50 0.50 in gypsum or plaster board 0.45 0.45 1. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 --------- --------- Total Unadjusted R -Values 41.15 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------- ------------------- ----- U-Value: (1 41.15 x 0.93) + (I 3'S�.2 x 0.07) 0.02�5 Btuh/sf-F Total R -Value: 0 0104 1 0.025 40.51 sf-F/ tuh a -2, \�\J-V\ � W W"'I' HVAC SIZING Page 11 HVAC Project Title .......... 1499 DAVE MILLER Date ........ 03/31/94 Project Address ........ --------------------- LA DUINTA 11 Documentation Author ... W J FINNELL Building Permit # Company ................ Finnell Telephone .............. 909-659-3961 Plan Check Date Compliance Method ...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone ........... 15 --------------------- MICROPAS4 v4.02 File-1499SQFT Wth-CTZ15S92 Program -HVAC SIZING User#-MP1325 User-Finnell Run-1499SQFT ------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 1499 sf Volume ..................... 13566 cf Front Orientation .......... Front Facing 90 deg (E) Sizing Location ............ INDIO Latitude ................... 33.7 degrees Winter Outside Design ...... 29 F Winter Inside Design ....... 70 F Summer Outside Design ...... 112 F Summer Inside Design ....... 78 F Summer Range ............... 30 F Interior Shading Used ...... No Exterior Shading Used ...... No Overhang Shading Used ...... No Latent Load Fraction ....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description (Btuh) (Btuh) --------------------------------- ----------- ----------- Opaque Conduction and Solar ...... 13088 5165 Glazing Conduction ............... 6324 5245 Glazing Solar .................... n/a 7149 Infiltration ...................... 7999 4741 Internal Gain .................... n/a 2550 Ducts ............................ 2741 24e5 Sensible Load .................... Latent Load ...................... Minimum Total Load 30152 n/a 27334 5467 30152 32801 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment.